TandD RTR5X 900 MHz Data Recorder User Manual 1

TandD Corporation 900 MHz Data Recorder Users Manual 1

Contents

Users Manual 1

Download: TandD RTR5X 900 MHz Data Recorder User Manual 1
Mirror Download [FCC.gov]TandD RTR5X 900 MHz Data Recorder User Manual 1
Document ID502078
Application IDxerACrbcLE9+zztXFcmMBg==
Document DescriptionUsers Manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize210.33kB (2629083 bits)
Date Submitted2004-12-29 00:00:00
Date Available2004-12-29 00:00:00
Creation Date2004-12-29 16:56:27
Producing SoftwareAdobe PDF Library 5.0
Document Lastmod2004-12-29 16:57:17
Document TitleUsers Manual 1
Document CreatorAdobe InDesign 2.0J

User’s Manual
Thank you for purchasing our product.
Carefully read this instruction manual
before using this unit.
��������� ��������� ��� ������������ ��� ������ ���������
2003.07 16004264080
■ Notices about this User’s Manual
Carefully read this manual so that you can properly use this product.
T&D Corporation accepts no responsibility for any malfunction of and /
or trouble with this product or with your computer that is caused by the
improper handling of this product and will deem such trouble or
malfunction as falling outside the conditions for free repair of the
attached warranty.
● All
rights of this user’s manual belong to T&D Corporation. It is prohibited
to use, duplicate and / or arrange a part or whole of this user’s manual
without the permission of T&D Corporation.
● Microsoft
and Windows are registered trademarks of Microsoft
Corporation USA and are binding in the USA and all other countries.
● Company
names and product names are trademarks or registered
trademarks of each company.
● Specifications,
without notice.
design and other contents are subject to change
● On
screen messages in this manual may vary slightly from the actual
messages.
● Please
notify the shop where you purchased this product or T&D
Corporation of any mistakes, errors or unclear explanations in this
manual. T&D Corporation accepts no responsibility for any damage or
loss of income caused by the use of our product.
● This
product has been designed for private or industrial use only. It is
not for use in situations where strict safety precautions are necessary
such as in connection with medical equipment, whether directly or
indirectly.
● We
are not responsible for any malfunction or trouble caused by the use
of our product or by any problem caused by the use of measurement
results of our unit. Please be fully aware of this before using our product.
● Some
of our products, which come under the category of strategic
goods in foreign trade law, need the permission of the Japanese
government to be exported outside of Japan.
● This
user’s manual cannot be reissued, so please keep it in a safe place.
● Please
ⅰ
carefully read warranty and provisions for free repair.
Software User Agreement
■ Escape Clauses
● T&D
Corporation does not guarantee the operation of T&D Recorder
for Windows .
● T&D
Corporation shall not accept any responsibility for any damage,
whether direct or indirect, that results from the usage of T&D Recorder
for Windows.
● Specifications
of T&D Recorder for Windows may be subject to
change and service may be terminated without advance notice to the
user. In such a case, T&D Corporation shall not be responsible for any
damages, whether direct or indirect, from the inability to use T&D
Recorder for Windows.
● T&D
Corporation has no obligation to correct any defects found in
T&D Recorder for Windows.
■ Copyright
● The
Copyright for T&D Recorder for Windows, including the program
and relevant documents, belongs solely to T&D Corporation.
● The
reprinting or redistribution for commercial purposes whether in
part or in whole, in magazines or as a part of any product is strictly
forbidden without the expressed consent of T&D Corporation. Any
inquires concerning commercial redistribution should be directed to
the Sales Department of T&D Corporation.
● Please
do not attempt to make any changes or modifications to T&D
Recorder for Windows.
ⅱ
Table of Contents
Introduction
●
Software User’s Agreement...................ⅱ
●
What is T&D Recorder for Windows ? ........1
●
Communication with Data Loggers ............3
Getting Ready
●
Installing the Software .......................5
●
Operating the Software ......................6
●
●
Computer Communication Settings
・Connecting the Communication Cable .......8
・Setting Up the Serial Port ..................9
Remote Unit Registration.....................11
・Other Remote Unit Registration Functions ....16
Basic Functions
●
●
●
●
ⅲ
RTR-51/52
・Start Recording ...........................21
・Downloading Recorded Data ...............23
RTR-53
・Start Recording ...........................25
・Downloading Recorded Data ...............28
RVR-52
・Start Recording ...........................29
・Downloading Recorded Data ...............32
RTR-57C
・Downloading Recorded Data ...............33
・Set Clock ................................39
・Set Upper and Lower Limits ................40
Temperature and Humidity Graph
●
●
Display Names and Functions ................41
Editing the Graph
・Changing the Graph Display ................45
・Graph Operation ..........................50
Multi-Scale Graph
●
●
Display Names and Functions ................51
Editing the Graph
・Changing the Graph Display ................55
・Graph Operation ..........................62
Event Viewer
●
Display Names and Functions ................63
●
File Information .............................65
●
Printing Preview and Printing .................66
●
Saving Recorded Data .......................67
●
Creating Text File ...........................69
●
Opening Data Files ..........................71
●
Re-installation ..............................72
●
Troubleshooting.............................73
●
Specifications...............................77
Other Functions
Other
ⅳ
What is T&D Recorder for Windows ?
■ Outline
By using T&D Recorder for Windows, you can easily display the data
measured and recorded with the RTR-51/52/53, RVR-52 via our
exclusive short-wave wireless technology in table or graph form and
control printing with your computer.
Upon opening T&D Recorder for Windows, a launcher window in which
icons are displayed will appear. By clicking an icon, the graph, settings,
and /or communication screen for that type of unit will be displayed.
This software requires the following operating environment:
Compatible OS Microsoft Windows 98 / Me / NT 4.0
Microsoft Windows 2000 / XP
PC / CPU IBM compatible equipped with more than Pentium 90MHz or
NEC 98 Series with serial communication (RS-232C D-Sub 9 pin).
Memory More than16MB memory capacity
Hard Disk More than 4MB of empty hard disc space
Monitor VGA (Above SVGA (800×600) is recommended)
More than 256 colors can be displayed
■ Basic Functions
● Group
and Remote Unit Registration
If you wish to carry out wireless communication between an RTR-57C unit
and RTR-51/52/53, RVR-52 unit, it is necessary to first complete via
computer the remote unit registration of the RTR-51/52/53, RVR-52 unit to
the RTR-57C. Remote units can be operated and managed in Groups.
● Display
of Data List Collected in RTR-57C
A list of all data collected at the time of downloading is displayed, from which
all or part of the data can be used to create files or graphs.
● Mixed
Use with Other Units is Possible
You can make graphs in which data from RTR-51/52/53 and RVR-52 units
are mixed. If TR-5/TR-7 Series data have been read into the RTR-57C unit,
management of such mixed data is also possible.
● Temperature
and Humidity Graph / Multi-Scale Graph
In temperature and humidity graphs, the graph or list of temperature and
humidity data is displayed. In multi-scale graphs, the graph or list of voltage,
pulse, temperature and humidity data is displayed. You can also set the
scale or units to match the type of downloaded data.
1
Can Display 8 Channels of Data in One Graph
Can simultaneously display up to 8 channels of recorded data downloaded
from a main unit in one graph.
Printing Graphs and Data Lists
You can print graphs displayed on screen in full color. When printing a data
list, the printing of every recording date is possible.
Measured Data List Display
In the measured data list display, the maximum, minimum, and average
values are shown in different colors.
● Event
Viewer
In the event viewer, a data list showing the time of events is displayed.
Print Preview and Print
Select the data to be printed and after checking it in the preview window
you can proceed to print.
● Creating
Text File
Recorded data can be saved in universal Text file format (such as CSV
Format) to be read and manipulated by all common spreadsheet software
such as Excel or Lotus.
2
Communication with Data Loggers
There are two methods to communicate with RTR-51/52/53, RVR-52
data loggers; they are [Optical Communication] and [Wireless
Communication].
■ Optical Communication
By using the communication cable, you can carry out direct communication
with a computer or with an RTR-57C unit.
1.Using the supplied communication cable, connect the RTR-57C to
your computer.
ゲ
ューイアサクター
ト
メニタスケンモニ
リス
ン デー ド アゲ
サ・
コキ
メイWL オン スイ シ
ソウ
WL
WL タ カイ
タ
デー ク
デー
キロ
llec
Co
Lis
2.To carry out communication, place the data logger face down on the
RTR-57C.
ゲ
ー アク
ュ イサ ー
ニ スン タ ト
メ タ ケ モニ ス
ゲリ
ー
ン デキ ア・
イ L コ ドイ サ
メ W L オン ス ウ シ
ソ
WL
タ カイ
Wー
タ
デーク
デロ
キ
Place the data logger
face down.
Connect to Computer
It is possible to carry out some operations such as recording start settings or
changes, and downloading recorded data via communication with an RTR-57C
unit without connecting to a computer. For details, please see the RTR-57C
User’s Manual.
ゲ
ー ア
ュ イ ク ー
ニ ス サ タ
メ タ ケンモニ スト
ー
ゲ
ン デ
ア リ
イ L キ ドイ ・
メ W L コオン ス ウサ
W L
ソ イシ
W ータ カ
デ ータク
デ ロ
キ
3
■ Wireless Communication
Downloading recorded data from a data logger in the field to an RTR-57C
unit can be carried out via wireless communication (Special Short-wave
Radio Data Communication).
1.Register the Remote Unit.
Via the RTR-57C, connect a data logger to your computer and using
the T&D Recorder for Windows software register that data logger as
a Remote Unit.
2.Place the Remote Unit in the actual place where you wish to make
measurements.
If direct and unobstructed, the communication range is about 100
meters.
Group
メイン メニュー
WL データスイアゲ
WL コキ ケンサク
WL オンド モニター
データ スイアゲ
データ ソウサ・リスト
キロク カイシ
Collect
List
100m
● If
direct and unobstructed, the communication range is about
100 meters.
3.Carry out the Wireless Communication Test.
There are instances when communication cannot occur within 100
meters. Please check to see if communication is possible by
running a Search for Remote Units that have been registered via
the RTR-57C.
4
Installing the Software
● Is Windows working properly?
If Windows is not activated properly, it may be impossible to install and run
T&D Recorder for Windows.
● Quit all applications.
If you are running other applications, make sure to quit them before
installation. If you have any permanently active software, such as a virus
check or scan program in your computer, make sure to also quit it.
■ Install the Software (T&D Recorder for Windows)
1.Start Windows.
2.Place the CD-ROM in the appropriate drive, and the 「Install Program」
window will automatically open.
● If
that window does not open automatically, open the 「My Computer」 window
and double-click on the icon for the CD-ROM.
[Install T&D Recorder
for Windows]
[START]
button
3.Select [Install T&D Recorder for Windows] and by clicking on the
[START] button the installation will begin.
4.Confirming the contents as you go, install the software according to
the directions.
After installation is completed, an icon for [T&D Recorder for Windows]
will appear in the Start Menu.
Operating the Software
■ Opening the Software
Open the software by clicking on [T&D Recorder for Windows] from the
list of programs in the Start Menu.
■ Main Window
Upon opening T&D Recorder for Windows, a launcher window in which
icons are displayed will appear. By clicking an icon, the graph, settings,
and / or communication screen for that type of unit will be displayed.
Menu Bar
Toolbar
Icon
● Menu
Bar
In the Menu Bar are Menus containing an array of commands. Click on the
desired menu in the menu bar to set or display functions for each type of
device.
By clicking [Display]-[ Change Icon Layout ] or [Change Icon Size], you can
select how you wish the Main Window to appear.
● Toolbar
Can choose to view or hide icons. You can also make this setting from the
Menu Bar by clicking [Start]-[Select Menu].
● Icons
By clicking on an icon, the graph or communication display will appear for
that type of unit. The graph and communication displays for each type of
unit can also be viewed by clicking on that unit’s type name in [Start] of the
Menu Bar.
■ See the Help Menu of the software for more detailed
information about how to use the software.
● To
search for unclear words or terms, click the [Help] Menu that appears in
the Menu Bar and then click on one of the tabs [Contents], [Index] or
[Search].
Contents
Index
Search
〔Contents〕
By clicking the mark of the classified topic, an explanation will be displayed.
〔Index〕
Select a key word from the key word list and by clicking the [Display] button,
the explanation will be displayed.
〔Search〕
Enter the key word you wish to search for and click the [Start Search]
button and the topic in which the key word is included will be displayed.
Then select the topic and click the [Display] button to have the explanation
displayed.
● Click
on the [Help] button in any dialog box and explanations about the
dialog box will be displayed.
● In
the graph display window, after clicking on the
in the toolbar, you can
click on any Menu, any Icon, or any part of the Main window and an
explanation will be displayed.
Computer Communication Settings
■ Connect the communication cable to your computer.
Connect the RS-232C communication cable (included in pack) to the
serial port of your computer.
Serial Port Markings
The communication cable connection is a
D-Sub 9 pin female. Please connect it to a port
that has markings such as these.
Note:
If the cable is connected to the wrong port, communication cannot take place.
● Be sure to securely connect the cable to avoid any communication failure
due to a loose connection.
●
■ Connect the Data Logger to your Computer.
If the data logger is an RTR-51/52/53, or RVR-52 unit, connect it to your
computer via an RTR-57C unit.
ゲ
ー アク
ュ イサ ー
ニ スン タ ト
メ タ ケ モニ ス
ゲリ
ー
ン デキ ア・
イ L コ ドイ サ
メ W L オン ス ウ シ
ソ
WL
タ カイ
Wー
タ
デーク
デロ
キ
Place the data logger face
down on the RTR-57C.
Connect the communication cable from
your computer to the RTR-57C unit.
■ Setting Up the Serial Port
Set the serial port to be used for communication with the data logger.
There are two ways to set up the serial port [Auto Detect] and [Select a
Port].
● When
you wish to use the same COM port to carry out communication
with different types of units.
Check [Set Common COM Port for All Types] and click the [OK] button to
complete at once the port setting for all types of units.
[Auto Detection]
[Serial Port Settings] tab
Detection
Results
[Auto Detect]
button
When setting up more
than one type at the
same time
[OK] button
[Close]
button
1.In the main window, open the setting, communication display of the
type of data logger connected to the computer and click the [Serial
Port Settings] tab.
2.Click the [Auto Detect] button to start the detection process.
3.When the detection is completed, a message will be displayed in the
[Detection Results] section.
4.By clicking the [OK] button, the setting process will be finished and
the port to which the data logger is connected will be set.
5.By clicking the [Close] button, the setting will be completed.
[Selecting a Port]
[Serial Port Settings] tab
Possible COM Ports
When setting up more
than one type at the
same time
[OK]
button
[Close]
button
1. Click the [Serial Port Settings] tab in the settings / communication
display of the data logger to be used.
2.From the [Possible COM Ports] list box choose and check the port
to which the data logger is connected.
3.Click [OK] button to finish set-up and close the dialog box.
4.By clicking the [Close] button, the setting will be completed.
10
Remote Unit Registration
■ Registering a Remote Unit
1.By selecting the icon [Remote Unit Registration], a message will be
displayed.
※ Remote unit registration can be carried out for each type of unit from the
setting / communication menu for that unit [Communication]- [Remote Unit
Registration].
《Enlarged Message》
[Yes] button
Collect Registration Info
This function allows you to collect all remote unit registration info in
the RTR-57C. That info (Group Name / Remote Unit Number /
Remote Unit Name) will be displayed in a list. In order to delete,
change or register any groups or remote units in an RTR-57C, it is
necessary to connect that RTR-57C to your computer and carry out
the [Collect Registration Info] before proceeding.
2.By clicking the [Yes] button, collection of the registration info will begin
and a list will be displayed.
The default setting for the
registered group name is
[Group 1].
Remote unit registration
into [Group 1] is possible.
11
● If
the registration info has not been collected or you wish to collect
again, click [Collect Registration Info] button in the [Registration
Contents] window to collect the registration info.
[Collect Registration Info]
button
3. Click the [Register] tab, and set the Group Name, Remote Name,
and Communication Frequency Channel.
[Register] tab
Group Name
Communication
Frequency Channel
Remote Unit Name
[Register]
button
[Close]
button
● Group
Names
Group Names can be entered with up to 8 letters.
You can also select an already registered group name and make slight
changes to make a new name.
12
● Communication
Frequency Channel
By clicking the [Set] check box you can select a channel number.
One Frequency Channel (0-3) can be set for each Group.
《Remote Registration Display》
●
●
The default frequency channel setting for Group 1 is ‘0’
If no settings are chosen, an unused frequency channel will be
automatically assigned.
NOTE:
● A frequency channel setting can only be made when registering a
new group.
● Once a channel has been set for a group it cannot be changed.
● The specified frequency channel will be used for all communication
with remote units in that group. If another RTR-57C is using the same
channel in the same area, communication may become unstable.
● Remote
Names
Remote Names can be entered with up to 8 letters. You can also select
an already registered remote name and make slight changes to create
a new name.
4.By clicking the [Register] button, registration will be completed.
● If
you are registering a number of remote units to the same group, place
each one on top of the RTR-57C and carry out the registration into the
same group.
● If you are registering units to different group names, please follow the
above steps over again.
13
5.Upon completion the [Registration Contents] will be displayed and
by clicking [Close] the registration will be finished and the window
closed.
[Close]
button
● By
clicking on a Group Name, the Frequency Channel for that group,
as well as, the Remote Unit Names and Numbers for that group will be
displayed.
Frequency Channel
Number of Possible
Registrations
Remote Number and Name
《[Registration Contents] display enlargement》
14
■ Position the remote unit(s)in the place(s)where
you want to measure and check if communication
is possible.
From an RTR-57C unit, it is possible to find any registered Remote Unit
and make sure communication can be carried out.
1.In the Main Window, activate [Find Remotes].
2.Choose the range in which to search and activate.
● If
you choose [All Groups], the search for remotes in all registered groups
will begin immediately.
● If you choose [Specify Group], select the desired group from the list to
start the search.
3.After the search has been completed, a list of possible Remote Units
for communication will appear in a list.
● Remote
an
Units for which communication is possible will be marked with
before its name.
For details, see the RTR-57C User’s Manual.
15
Other Remote Unit
Registration Functions
The following operations can be carried out in the Remote Registration
Window. Be sure to connect the RTR-57C to your computer and collect
the registration info of RTR-57C before carrying out these operations.
[File] Menu
[Collect Registration Info]
button
[Return to Original]
button
[Send] button
[Set Number of Possible Registrations]
button
■ 「File」Menu: [Save Registration Contents]
You can save the Group and Remote Unit Registration Info to a file.
NOTE:
● You cannot edit the contents of registration info from a saved file.
● You cannot send text file.
1. From the [File] Menu, choose [Save Registration Contents to File].
2. Designate the saving location and enter a file name.
3. Click the [Save] button to save the file.
16
■ [File] Menu: [Save as Text File]
You can save the Group and Remote Unit Registration Info as a text file.
NOTE:
You cannot edit the contents of registration info from a saved file.
1. From the [File] Menu, choose [Save as Text File].
2. Designate the saving location and enter a file name.
3. Click the [Save] button to save the file.
■ [Set Number of Possible Registrations] Button
There are two patterns for setting and registering the largest number of
groups and remotes into one RTR-57C.
・Pattern 1: 
・Pattern 2: 
The Default Setting is: Pattern 1: 
NOTE:
If changes are made to the pattern, the Remote Unit Registration Contents
saved in the RTR-57C will be automatically returned to the original default
contents. Please be careful.
1. Select a pattern.
2. Click [OK] button to complete the change.
Check one
17
[OK]
button
■ [Remote Registration Contents] – [Return to Original]
Button
All info saved in the RTR-57C will be erased and will be returned to as it
was when it left the factory: Group Name: Group 1 / Remote Unit: NONE
/ Communication Frequency: 0
1. Connect the RTR-57C unit you wish to return to the factory settings.
2. Click the [Return to Original] button, and the process will begin.
■ [Remote Registration Contents] – [Send] Button
If the Registration Contents are the same in a number of RTR-57C Units,
communication is possible between 1 Remote Unit and any number of
RTR-57C Units. To make the contents the same, it is possible to transmit
them to a number of RTR-57C Units.
NOTE:
● By sending, you will delete all prior registration contents.
● If the number of files to be sent is over the number of possible registrations,
it will be impossible to transmit them. Please see p.17 for details about the
possible number of registrations.
1. Save the registration contents you wish to send. (See p. 16 for details)
2. Click [Open] from the [File] Menu and open those Remote
Registration Files you wish to send.
3.
The contents of those files will be displayed in the Remote
Registration Contents Window.
4. Click the [Send] button to begin transmission.
18
■「Change / Delete」
You can make changes to a registered Remote Unit Name or delete a
Group or Remote Unit.
[Change] button
[Delete Group] button
[Delete Remote Unit]
button
[Change] Button…Only for Remote Names
1.
Select the Group in which the Remote you wish to change is
registered.
2. Select the Remote Number or Name and enter the new Remote Name
for the unit.
3. Click the [Change] button to send the new information.
[Delete Group] Button
By deleting a Group, all Remote Units registered to that Group will be
automatically deleted.
1. Select the Group Name you wish to delete.
2. Click [Delete Group] to begin the process.
[Delete Remote] Button
1.
Select the Group Name in which the remote you wish to delete is
registered, then select the Remote Number(s) or Name(s).
2. Click [Delete Remote Unit] to begin the process.
19
■「Remote Unit Info」
This allows you to view the registration contents of any Remote Unit
presently connected to the RTR-57C. The Registration Contents of units
registered to a different RTR-57C can be viewed as well.
1.
Place the Remote Unit from which you wish to collect remote info
face down on the RTR-57C.
2.
Click the [Collect Remote Unit Contents] button and the info will
appear for that unit.
[Collect Remote
Unit Contents]
button
● RTR-57C
Registration Status:
● Wireless
Recording Start
If remotes are registered in the presently connected RTR-57C
: exist
If remotes are not registered in the presently connected RTR-57C
: Not exist
If registration info has not been collected from presently connected RTR-57C
:-
If forbidden to start recording: FORBID
If permission to start recording: PERMIT
20
RTR-51/52: Start Recording
1.In the main display, click the icon [RTR-51/52].
2.Click the [Start Recording] tab and make recording settings.
[Start Recording]
button
「Start Recording」
tab
[Get Settings] button
[Detailed Settings] button
[Stop Recording] button
[Close]
button
● Recording
Start Date / Time: 
Select the Recording Start Method
・Programmed Start: Recording will begin on the day and time entered.
・Immediate Start: Recording will begin as soon as settings are completed.
● Recording
Interval: 
One-time: When the number of readings has reached 16,000, the unit display
will read FULL and recording will automatically stop.
Endless: When the number of readings reaches 16,000, the next one will
overwrite the oldest or first reading.
● Temperature
。
Unit: 
By clicking ▼ you can select from the recording interval list.
● Recording
Mode: 
。
Change the display of temperature on the Thermo Recorder between [℃ ] and [ F] .
※ By clicking the [Get Settings] button, registration contents and remaining
battery life will be displayed.
3. After making all the desired settings, click the [Start Recording]
button to transmit them.
25
4. After transmission has been completed the communication result
will appear. By clicking [OK], the set-up process will be finished. By
clicking [Close], you can close the window.
■ [Main Unit Display Settings] Button
Set the desired unit of measurement display for the RTR-53 unit LCD display.
1.Select the unit of display you wish to set.
2.Click the [Send] button to complete the setting.
Check one
[SEND]
button
■ [Get Settings] Button
The Remote Unit recording settings, registration contents, and remaining
battery life are displayed.
● Registration
contents: If a settings transmission was received it displays
the Group and Remote Name(s).
● Remaining battery life: If a settings transmission was received it displays
the remaining battery life.
26
■ [Detailed Settings] Button
Check one
[OK]
button
By checking, you can make entries.
● Start
Wireless Communication: Restrict the permission to start
recording by wireless communication.
1.If you wish to forbid the starting of recording by wireless
communication, check [FORBID]; to allow, check [PERMIT].
2.Click [OK] to complete and close.
● Upper
and Lower Limits: To check whether or not the data downloaded
into the RTR-57C falls within a certain set range.
1.By checking the [Set Limits] box, you will be able to enter an upper
and lower limit.
2.Click [OK] to complete and close.
■ [Stop Recording] Button
Stop current recording of data logger.
27
RTR-53: Downloading Recorded Data
■ Connect the RTR-53 unit for communication with
your computer.
※ See P.3 or P.8 for about how to connect.
■ Download Recorded Data.
1.In the main window, click the icon [RTR-53].
2.Click the [Download Recorded Data] tab.
[Download Recorded
Data] tab
Select the
downloading range
[Download]
button
[Detailed Settings]
button
[Close]
button
3.After selecting the downloading range, click the [Download] button
to start downloading.
4.When downloading has been completed a graph will be displayed.
If you have checked [After downloading, specify file in which to save
data] in the Detailed Settings, please view the graph after specifying
the file in which you wish to save the downloaded data.
■ [Detailed Settings] Button
You can make settings for the processing
of the downloaded recorded data.
Check one
[OK]
button
1. Select the desired processing method.
2. Click [OK] button to complete the setting.
28
RVR-52: Start Recording
1.In the main display, click the icon [RVR-52].
2.Click the [Start Recording] tab and make recording settings.
[Start Recording]
button
「Start Recording」
tab
[Get Settings] button
[Detailed Settings] button
[Stop Recording] button
[Close]
button
● Recording
Start Date / Time: 
Select the Recording Start Method
・Programmed Start: Recording will begin on the day and time entered.
・Immediate Start: Recording will begin as soon as settings are completed.
● Recording
Interval: 
One-time: When the number of readings has reached 16,000, the unit display
will read FULL and recording will automatically stop.
Endless: When the number of readings reaches 16,000, the next one will
overwrite the oldest or first reading.
※ In event recording, the number of readings is 8,000.
● Measurement
Mode: 
Voltage/Instantaneous Value: R e c o r d t h e v o l t a g e m e a s u r e m e n t a s t h e
instantaneous value for each recording
interval span.
29
Voltage/Average Value: Record as the average value for each recording
interval span. The average value for recording
intervals under 15 seconds will be calculated as
the average of the measurements from every 1
second. The average for intervals over 20
seconds will be calculated as the average of
the measurements from every 2 seconds.
Pulse/ Lo→Hi: Record the number of signals rising within the
recording interval you have set.
Pulse/ Hi→Lo: Record the number of signals falling within the
recording interval you have set.
Pulse/ Event: Record the time of any event; a rising (Lo to Hi)
or falling (Hi to Lo) waveform that occurs for
more than 1 second at an input voltage range of
between 0-30V.
※ By clicking the [Get Settings] button, registration contents and remaining
battery life will be displayed.
3. After making all the desired settings, click the [Start Recording]
button to transmit them.
4. After transmission has been completed the communication result
will appear. By clicking [OK], the set-up process will be finished. By
clicking [Close], you can close the window.
■ [Get Settings] Button
The Remote Unit recording settings, registration contents, and remaining
battery life are displayed.
● Registration
contents: If a settings transmission was received it displays
the Group and Remote Name(s).
● Remaining battery life: If a settings transmission was received it displays
the remaining battery life.
30
■ [Detailed Settings] Button
[OK]
button
Check one
By checking, you can make entries.
● Start
Wireless Communication: Restrict the permission to start
recording by wireless communication.
1.If you wish to forbid the starting of recording by wireless
communication, check [FORBID]; to allow, check [PERMIT].
2.Click [OK] to complete and close.
● Upper
and Lower Limits: To check whether or not the data downloaded
into the RTR-57C falls within a certain set range.
1.By checking the [Set Limits] box, you will be able to enter an upper
and lower limit.
2.Click [OK] to complete and close.
■ [Stop Recording] Button
Stop current recording of data logger.
31
RVR-52: Downloading Recorded Data
■ Connect the RVR-52 unit for communication with
your computer.
※ See P.3 or P.8 for about how to connect.
■ Download Recorded Data.
1.In the main window, click the icon [RVR-52].
2.Click the [Download Recorded Data] tab.
[Download Recorded
Data] tab
Select the
downloading range
[Download]
button
[Detailed Settings]
button
[Close]
button
3.After selecting the downloading range, click the [Download] button
to start downloading.
4.When downloading has been completed, a Graph or Event Viewer
will be displayed.
If you have checked [After downloading, specify file in which to save
data] in the Detailed Settings, please view the graph or Event Viewer
after specifying the file in which you wish to save the downloaded data.
■ [Detailed Settings] Button
You can make settings for the processing
of the downloaded recorded data.
Check one
[OK]
button
1. Select the desired processing method.
2. Click [OK] button to complete the setting.
32
RTR-57C: Downloading Recorded Data
■ Connect RTR-57C to your computer to carry out
communication.
※ For details about how to connect, see the user’s manual for RTR-57C.
■ Collect RTR-57C Data Info.
1.In the main window, click the icon [RTR-57C].
2.Click the [Download Recorded Data] tab.
[Download Recorded Data] tab
[Collect Data Info]
button
3.By clicking the [Collect Data Info] button, communication will be started
and the data list saved in RTR-57C will be displayed.
Data List
[Quit Collecting
Data Info] button
33
【Quit collecting data info while in progress】
By clicking [Quit Collecting Data Info], the collection will be stopped.
①
②
① Collection of data info has been completed. All operations are possible.
② Data downloading and deletion can be done, but data info cannot be
displayed.
■ Download Recorded Data.
1.Select the data to be downloaded from the data list.
※ To download several sets of data at one time, see p.36-37 for details.
Select data
34
2.By clicking the [Download] button, downloading will be started.
[Cancel Downloading]
button
● By
clicking the [Cancel Downloading] button, you can stop downloading
at any time.
3.When downloading has been completed, the graph will be
displayed.
※ If you have checked [After downloading, specify file in which to save
data] in the Detailed Settings, please view the graph after specifying the
file in which you wish to save the downloaded data.
■ [Detailed Settings] Button
You can make settings for the processing of the downloaded recorded data.
1.Select the desired processing method.
2.Click [OK] button to complete the setting.
Check one
35
[OK]
button
■ Downloading Several Sets of Data at One Time
You can make settings for the processing of the downloaded recorded data.
1.While holding down the [Shift] key or [Ctrl] key, click on those sets of
data you wish to download.
(For Example)
● If you wish to download files not in a row, such as No.1 and No.3, hold
down the [Ctrl] key and click on files for No.1 and No.3.
●
If you wish to download files in a row, such as No.1, No.2 and No.3,
hold down the [Shift] key and click on the files for No.1 to No.3.
Use the [Shift]
key to select
Use the [Ctrl]
key to select
2.Click on the [Download] button, and downloading will be started.
[Cancel Downloading]
button
3.When downloading has been completed, a graph will be displayed.
※ If you have checked [After downloading, specify file in which to save data]
in the Detailed Settings, please view the graph after specifying the file in
which you wish to save the downloaded data.
36
● If
you have checked [After downloading, specify file in which to save
data] and you have selected several sets of data, at the end of the
specified file name of every recorded data will appear the list number
(No.1→001, No.2→002,No.3→003…)
File Name
List Number
Extension Code
trx : Universal Thermo Recorder type file
vtc : Voltage Recorder type file
pv5 : RVR-52 voltage, pulse data file
rp7 : RVR-52 event data file
● If
you have checked [After downloading, automatically show graph]
and have selected several sets of data, it is possible to display the
selected data in the same graph. Moreover, in the graph display by
entering which file you wish the data to be saved, it is possible to save
several sets of data into one file.
※ Each kind of data is displayed in the following graphs:
Temperature/Humidity data: Temperature/Humidity Graph
Voltage/Pulse data: Multi-scale Graph
Event data: Event Viewer
37
【Other Button Functions】
①
②
③
④
① [Data Info Display] Button
Displays info about data for all selected data from the list.
② [Delete Data] Button
Deletes selected data saved in the RTR-57C from the software.
③ [Delete All Data] Button
Deletes all data saved in the RTR-57C from the software.
④ [Select All] Button
Selects all data in list to be downloaded at the same time.
38
Setting the RTR-57C Clock
Set the RTR-57C clock from your computer.
1.In the main window, click the icon [RTR-57C].
2.Click the [Set Clock] tab
[Set Clock] tab
[Close]
button
[Set Clock]
button
●
Set specified time
If checked: The date/time you enter will be set as the date/time in the
RTR-57C.
If not checked: The current date/time of your computer will be set as the
date/time in the RTR-57C.
3. Select setting method and by clicking the [Set Clock] button, the
setting will be transmitted.
4.Click [Close] button to complete the setting.
39

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Modify Date                     : 2004:12:29 16:57:17-05:00
Create Date                     : 2004:12:29 16:56:27-05:00
Title                           : 
Creator                         : Adobe InDesign 2.0J
Producer                        : Adobe PDF Library 5.0
Page Count                      : 44
Mod Date                        : 2004:12:29 16:57:17-05:00
Creation Date                   : 2004:12:29 16:56:27-05:00
Metadata Date                   : 2004:12:29 16:57:17-05:00
Tagged PDF                      : Yes
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SRDRTR5X

Navigation menu