BODY COMPOSITION ANALYZER
TBF-215
INSTRUCTION MANUAL

This device features radio interference suppression in compliance with valid EC Regulation 89/336/EEC.

FEDERAL COMMUNICATIONS COMMISSION NOTICE
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio or television technician for help.

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Tanita
Corporation may void the user's authority to operate the equipment.

14-2,1-chome,Maeno-cho,Itabashi-ku
Tokyo,Japan
Tel:(03)3968-2123 / (03)3968-7048 Fax:(03)3967-3766

2625 South Clearbrook Drive
Arlington Heights, Illinois 60005 U.S.A.
Toll Free : (800) 826-4828
Tel : 847-640-9241
Fax : 847-640-9261
http : //www.tanita.com

Unit 301-303 3/F Wing On Plaza,
62 Mody Road, Tsimshatsui East,
Kowloon, Hong Kong
Tel : +852-2838-7111
Fax : +852-2838-8667

Dresdener Strasse 25
D-71065 Sindelfingen,
Germany
Tel : 07031-61896
Fax : 07031-618971

Tanita House, Willow Avenue,
Denham, Uxbridge, Middlesex
UB9 4AF, Great Britain
Tel : 01895-232355
Fax : 01895-233116

3-3 Bis, Rue Charcot,
92200, Neuilly-Sur-Seine,
France
Tel : 01-55-24-99-99
Fax : 01-55-24-98-68

TBF2157021(1)



Please read this INSTRUCTION MANUAL carefully and keep
it handy for future reference.

2. Specifications

1.Table of Contents
1. Table of Contents

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

2

2. Specifications

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

3

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

4

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

4

●

●

●

3. Important Notes for Users
■Caution Symbols
●

●

●

●

●

●

■Maintenance
■General Instructions for Accurate Measurement
●

4. Components
■Overview

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

5

●

●

●

●

●

●

●

5

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

6

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

6

■Control Panel Functions

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

7

5. Set Up
■Assembly Instructions
●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

8

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

8

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

9

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

10

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

12

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

13

■Loading Printer Paper
■Pre-Set Printer Functions
●

●

●

■Setting the Original Mode

6. Operating Instructions
■Body Composition Analysis
●

●

■Weight Only Function

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

17

7. Explanation of the Print Out

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

18

8. Trouble Shooting the Printer

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

19

9. General Trouble Shooting

●

●

●

●

●

●

20

●

●

●

●

10. RS - 232 C Interface Instructions

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

●

Impedance Measurement

Weight Measurement
Height Measurement

Input Items

13,14,15,16

●

●

●

Model

●

●

●

●

●

●

●

●

●

21,22

Output Items

Measurement System
Measurement Frequency
Measurement Current
Electrode Material
Measurement Style
Measurement Range
Measurement System
Maximum Capacity
Minimum Graduation
Range of Measurement
Clothes Weight
Gender
Body Type
Age
Height Rod
Height
Manual Input
Target Body Fat %
Target Body Fat %
Weight
Gender
Body Type
Display
Age
Rod
Height
Manual
Fat %
Body Type
Gender
Age
Rod
Height
Manual
Weight
Print
BMI
Out
BMR
Impedance
Fat %
Fat Mass
FFM
TBW
Others

Display
Cable Length Between Platform and Control Box
Output Data Interface
Power Source
Rated Power
Power Consumption
Temperature Range of usage
Platform
Weight of Equipment
Control Box

2

TBF-215
Tetrapolar Bioelectrical Impedance Analysis
50kHz
500μA
Pressure Contact Stainless Steel Foot Pads
Between Both Feet
150∼900Ω
Strain Gauge Load Cell
200kg
440lb
31st6lb
0.1kg
0.2lb
0.2lb
90∼213cm
3∼7ft
0.5in increments
1cm increments
0∼200kg/0.1kg increments
0∼440lb/0.2lb increments
0∼9st13.8lb/0.2lb increments
Male/Female
Standard/Athletic
7∼99 years old/1 year increments
90∼213cm/1cm increments
3ft∼7ft/0.5in increments
90∼249cm/1cm increments
3ft∼7ft11.5in/0.5in increments
4∼55 %
4∼55 %
0∼200kg/0.1kg increments
0∼440lb/0.2lb increments
0∼31st6lb/0.2lb increments
Male/Female
Standard/Athletic
7∼99 years old/1 year increments
90∼213cm/1cm increments
3ft∼7ft/0.5in increments
90∼249cm/1cm increments
3ft∼7ft11.5in/0.5in increments
1∼75 % / 0.1 % increments
Standard/Athletic
Male/Female
7∼99 years old/1 year increments
90∼213cm/1cm increments
3ft∼7ft/0.5in increments
90∼249cm/1cm increments
3ft∼7ft11.5in/0.5in increments
2∼200kg/0.1kg increments
4.4∼440lb/0.2lb increments
4.4∼31st6lb/0.2lb increments
0.1 increments
1kJ increments / 1kcal increments
150∼900Ω / 1Ω increments
1∼75 % / 0.1 % increments
0.1kg increments
0.2lb increments
0.1kg increments
0.2lb increments
0.1kg increments
0.2lb increments
Desirable Range for FAT% and FM ( Standard and 20∼79 years old ONLY )
3 Rows, 5Digits LCD
2m/6ft6.5in
RS-232C ( D -sub 9 pins Male Connector )
AC Adapter ( included ) Center Minus
DC5V 3.5A
17.5W
0∼35˚C/32∼95˚F
15.6kg / 34.4lb
0.9kg / 2.0lb

3

3. Important Notes for Users



■ Caution Symbols

In order to insure optimum performance of this Body Composition Scale, please observe the following instructions:
● Unplug the unit from the wall outlet when it will not be in use for long periods of time.
● Always turn the equipment off before unplugging from a wall outlet.

Thank you for purchasing this precision crafted Tanita product. For optimum performance and safety, please familiarize

● Never disassemble the equipment. Always call the nearest Tanita dealer or branch office for instruction.

yourself with the Caution Symbols below. These symbols are designed to alert the user to potential hazards when using this

● In order to reduce the risk of a short circuit, please keep any liquid or metal objects (paper clips, etc.) away from

equipment. Ignoring these Caution Symbols may result in serious injury, or damage to the product.

the printer.

Please be sure to review before proceeding with the INSTRUCTION MANUAL.

WARNING
WARNING
CAUTION

WARNING

Maintenance

● Do not drop the unit, and avoid locations with constant vibration.
● Avoid placing the platform or display in direct sunlight, or too close to a heating unit.

This symbol indicates the possibility of serious injury if the product is
mishandled or instructions are ignored.

● Avoid rapid temperature fluctuations.

This symbol indicates the possibility of ELECTRICAL SHOCK. Please pay
special attention to sections which bear this mark.

● When transferred to any location where there is a difference of more than 20˚C(40˚F), wait 2 hours before using.

This symbol indicates the possibility of physical injury or equipment damage if
instructions are ignored.
This symbol indicates general precautions that should be taken when using this
product.

● Individuals with a Pacemaker or Other Internal Medical Devices:
Because Tanita`s Body Composition Analyzers send a weak electrical current through
the body, Individuals Who Have a Pacemaker or Other Internal Medical Devices
Should Not Use This Product. The weak electrical signal may cause such internal
devices to malfunction.
● Cross Contamination
The Body Composition Analyzer should be used with bare feet. Please be sure to clean
the scale platform with appropriate disinfectant after each use. Never pour any liquid
directly on the scale platform, as it may leak and cause internal damage. Use a soft
cloth and appropriate disinfectant or mild cleaners to wipe off platform. Do not wipe
the platform with strong chemicals.
● Please consult your Physician before begining any weight management program and
for help in establishing your target body fat percent. Tanita Corporation is not
responsible for establishing individualized target body fat percent values.
● To reduce the risk of fire hazards or equipment damage, use only the original AC

● Excessive humidity may damage the equipment.



General Instructions for Accurate Measurement
The body composition analyzer is designed for standard and athletic individuals. However, certain individuals may
not receive accurate results, as they fall outside the population for which Tanita equations were developed.
● Because this body composition analyzer uses a minor electric current to measure impedance (electrical resistance),
best results will be observed when measurement is taken in bare feet.
● If there are calluses on the soles of the feet, or a client is wearing thin nylons, accurate measurement may still be
possible. Place 0.5 ml of saline or water in the center of each electrode. This will act as a conductant, and may
allow the current to pass freely through a thin barrier.
● Poor contact between the feet and electrodes may produce an error message. Heels should be placed directly on
top of the posterior electrodes, while the front part of the foot needs to be in contact with the anterior electrodes.
Also, make sure the soles of feet are free of excess dirt, as this may also act as a barrier to the mild current.
● Keep the electrodes clean by wiping them with disinfectant.
● False results may be reported after excessive food/fluid intake, or after periods of intense exercise.
● Interpretation of Results
The data provided by this machine, as well as any supplementary information such as diet or exercise programs
based on this data, should be interpreted by a licensed professional.
For more information regarding Accurate Measurement, please refer to the Technical Notes booklet.

adapter provided by TANITA.
● Inserting and Removing the Power Cord
WARNING
● To reduce the risk of electric shock or product damage, never insert or remove the

power cord with wet hands.

● To avoid a fire hazard, make sure the wall outlet is functioning properly; avoid using
multiple outlet extension cords.

CAUTION

● To reduce the chance of inaccurate measurement, be sure to place the weighing
platform on a flat and stable surface.
● To reduce risk of injury or equipment malfunction, always step on the platform slowly.
● When handling printer unit, avoid any sharp edges.
● To reduce the risk of fire hazards or equipment damage, use only the original AC
adapter provided by TANITA.
● When transferring this product, be sure that it remains in an upright position, and do
not carry from the height rod only. Hold the plate underneath the base. Failing to do so
may damage the height rod, or the weighing platform.
● Do not lean against the height rod.

4

5

4. Components
■ Overview

Control Panel Functions
Height Setting Button : Height Confirmation

Height Bar

Feed Key

Clothes Key

Weight Only Key

Advances the print paper

To specify clothes weight

Measures body weight only

Kg/Lb./(st.lb) Key
Changes measurement unit

ON/OFF Key

Numerical Key Pad

Turns the power
on or off

Control Box

Number Entry Keys

Printer Cover
Printer Dispenser Cover

Height Rod

Body Type Keys

Control Panel

To select the appropriate body type
Tanita defines “athlete” as a person involved in intense
physical activity of at least 10 hours per week and who has a
resting heart rate of approximately 60 beats per minute or
less. Tanita’s athlete definition includes “lifetime of fitness”
individuals who have been fit for years but currently exercise
less than 10 hours per week.

Digital Display

Connection Cable

Tanita’s athlete definition does not include “enthusiastic
beginners” who are making a real commitment to exercising
at least 10 hours per week but whose bodies have not yet
changed to require the Athlete mode.

Level Gauge

CE Key
Clear Entry key

Confirm Height Key
Height Entry

Please see Technical Notes booklet for further explanation.

Weight Platform

Rear View of Control Panel
AC Adapter
Power Cord
Bottom Plate
DC Jack

Cord Cover ( Under Bottom Plate )
RS - 232 C Port
Anterior Platform Electrodes

Jack for the weighing platform

Posterior Platform Electrodes

6

7

5. Set Up
■ Loading Printer Paper

■ Assembly

Height Rod



Control Box

Please change paper when red lines appear along the sides of the paper.

WEIGHT
CLOTHES
MALE
BS232C

kg
lb / st.lb
cm

INPUT SV

Weighing Platform Cable

AC Adapter Plug

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Power Cord

1. Turn the unit on
Please lower the height rod to the resting position, and
turn the unit on by pressing the ON/OFF key.
“P-End”will flash on the middle of the LCD.
If“E-15”is shown, please lower the height rod to the
resting position. The error message will disappear.
If you do not want to use paper, press the CE key to
continue measurement with no paper.
When there is no“P-End”message, but the printer fails to
print, the chosen number of print outs may be“0”. Select
the number of print outs greater than“0”.(See p.10“PreSet Printer Function”)
2. Remove the Paper Dispenser Cover by lifting it up from
the back.

Connecting the Weighing Platform to the Control Box
1. Connect the cable from the weighing platform to the jack located on the back of the control box. The ▲ on the plug

3. In a straight line, cut approximately 1 inch (3 cm) off of the

should be facing up when inserted.

paper roll, this will ensure smooth feeding.

2. Connect the plug of AC adapter to the DC jack located on the back of the control box.
3 cm

3. Insert the power cord to the AC adapter, and plug it into a power outlet.

1 inch

WARNING
In order to reduce the risk of electric shock, never insert or remove the power cord with wet hands.
Use only the Tanita AC adapter provided with the unit.
Place the platform on a flat, level surface.
Leveling the Weighing Platform
・ For optimum accuracy, place the unit on a flat and level surface.
・ Check the level gauge (located on the base) to make sure the cone is in the center of the red circle.
・ The weighing platform has adjustable feet to ensure a level and stable weighing surface. If the cone is not in the center of
the red circle, it can be centered by turning the feet counter-clockwise.

4. Insert the paper in the holder as displayed. Be sure to feed
the paper straight into the automatic feeder. As the front
edge of the paper enters the appropriate slot, it will
automatically feed. Once the paper feeds, it will exit the
paper feed slot located on the printer cover, and be cut.
Remove excess paper from the Printer Cover.
Press the FEED key when paper needs to be advanced.

5. Replace the Paper Dispenser Cover as displayed.
Please refer to P. 19 for Trouble Shooting The Printer.

Red Circle



Only use Tanita thermal paper. Tanita can not guarantee
the performance of the printer if paper supplied from
outside sources is used.

Check the level gauge (located on
the base) to make sure the cone is
in the center of the red circle.

8

9

■ Pre-Set Printer Functions



All units come factory pre-set to print 1 copy in the English language. If change is necessary,
please follow these instructions:
WEIGHT
CLOTHES
MALE

+

cm
ft.in

ATHLETIC

AGE

STEP ON

% FAT

CLOTHES
MALE

kg

key, and press the

ON/OFF key once. Release the 0 key after“Prt-1”is
displayed on the screen.

2. Select the desired number of print outs.
Using the number keys, enter the quantity of print outs
desired. As many as nine are possible

ATHLETIC

AGE

STEP ON

% FAT

MALE

0

cm
ft.in

CLOTHES

1. Press and hold the

lb / st.lb

FEMALE

WEIGHT

∼

lb / st.lb

FEMALE

WEIGHT

∼

kg

kg
lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

TANITA
BODY COMPOSITION
ANALYZER
TBF-215
BODY TYPE
STANDARD
GENDER
MALE
AGE
32
HEIGHT
175 cm
WEIGHT
73. 3 kg
BMI
23. 9
BMR
7266 kJ
1737 kcal
IMPEDANCE
464 Ω
FAT%
16. 0 %
FAT MASS
11. 7 kg
FFM
61. 6 kg
TBW
45. 1 kg
DESIRABLE RANGE
FAT%
8–20 %
FAT MASS
5. 5–15. 7 kg

1

This section prints the both
the body type and body
composition data of the
current user.

- 9 : Quantity of print outs

0 : No print out
3. Language Selection



If “0” has been selected for the number of print outs
in Step 2 above, it will not be possible to preset this

TARGET BF% is :

10 %

item.
The LCD will automatically advance to the Language

Predicted weight :

Selection Screen. The current language selection will be
displayed as a numerical value.

68. 4 kg

Predicted fat mass :

Example: (LNG-1) denotes English as the selected

FAT TO LOSE:

language.
Select a preferred language by pressing the corresponding

2
3
4
5
6

: English
: French
: German
: Italian
: Spanish
: Dutch

4. The display will automatically change to the initial entry
WEIGHT

kg
lb / st.lb

screen after this procedure is finished.

cm

If“E-15”is shown, please lower the height rod to the

FEMALE

ft.in

resting position. The error message will disappear.

ATHLETIC

AGE

Normal functions may now be resumed. If further change

STEP ON

% FAT

CLOTHES
MALE

to Pre-Set Printer Functions is desired, please turn off the
unit, and refer to steps 1-3 above.

10

4. 9 kg

Consult your physician
before beginning any
weight management program. Tanita is not responsible for determining your target BF%.

number on the key pad.

1

6. 8 kg

This section calculates the
amount of fat that should be
lost or gained to achieve the
Target BF% (preset by the
user and health care
professional).


Target Function

Input

Print Out

STANDARD
ON
[1]

ATHLETIC
TARGET BF 00%

OFF

STANDARD

[0]

ATHLETIC

For this Goal Setter Mode, please refer to the page 12.

11

6. Operating Instructions


■ Body Composition Analysis

Setting the Original Mode

This process is utilized to select whether or not you use the target body fat ratio function. (See the printout sample
on page 18.)



Do Not Step On The Weighing Platform Until All Data Has Been Entered, And The Flashing Arrow Appears
Next To [STEP ON].


The target body fat ratio function is deactivated when this product is shipped from factory.
WEIGHT
CLOTHES

FEMALE

ft.in

1. While pressing the
or
key, switch on
the power.
[0] : The target body fat ratio function is deactivated
[1] : The target body fat ratio function is activated

ATHLETIC

AGE

If the number of print outs is set to “0” during

STEP ON

% FAT

WEIGHT
CLOTHES
MALE

WEIGHT

0

CLOTHES
MALE

or

1

kg
lb / st.lb
cm

kg



MALE

ATHLETIC

AGE

STEP ON

% FAT

cm

kg
lb / st.lb

ft.in

After a momentary automatic display check, the ▲ mark

ATHLETIC

AGE

STEP ON

% FAT

and “0.0”will flash on the LCD.
If“E-15”is shown, please lower the height rod to the
resting position. The error message will disappear.

the process of “Setting the Number of Print

If measuring units need to be changed, do so at this time

Outs and Language” on page 18, you cannot

by pressing the kg/lb (st.lb) key. An arrow on the LCD
will follow the selection of weighing units.

preset this item.

Throughout data entry, mistakes may be corrected by
pressing the CE key. Follow the flashing arrow on the
LCD for proper sequence.
2.

2. After the input is completed, the display will
automatically change to the measurement screen.

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Press the ON/OFF key to turn on the
Power after confirming the height rod
is at the resting position.

FEMALE

WEIGHT

MALE

lb / st.lb

cm
ft.in

WEIGHT

1.

lb / st.lb

FEMALE

CLOTHES

kg

CLOTHES
MALE

∼

kg

This function will automatically subtract the chosen amount of

lb / st.lb

clothes weight. Press the 0 - 9 keys.

cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Enter Clothes Weight (Optional)

Example : 2.0 kg = Press the 2
: 4.0lb = Press the 4

.

0 keys.

.

0 keys.

Clothes weight can be entered by 0.1kg/0.2lb increments .
Note :st.lb. is not available when entering clothes weight ,
please use only lb. units.



After entering the last digit, the flashing arrow on the LCD
will automatically appear next to the Male Icon, Female

The equipment will start up with these settings next time you use it.

Icon, and Athletic on the LCD.
WEIGHT

Select the Body Type.

lb / st.lb

Select the Body Type from Standard Male, Standard

cm

Female, Athletic Male and Athletic Female. Please use the

FEMALE

ft.in

Athletic key when the user is 17 years or older and also

ATHLETIC

AGE

meets the following criteria.

STEP ON

% FAT

CLOTHES
MALE

12

kg

3.

For Tanita's definition of "Athlete" see page 7.

13

e. g., Press [3] and [2].

cm

MALE
FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Enter Age
* If the user is 32 years old or younger.

lb / st.lb

CLOTHES

∼

4.

kg

WEIGHT

* If the user is 9 years old or younger
Example: press [0] and [9].
* If ages 16 or less are entered, even if Athletic is selected for
the Body Type, it will be automatically changed to Standard.

5.
kg

WEIGHT

~

After you input the height, “GOAL” will automatically
flash on the display. Input the target body fat ratio
desired using the numerical keys.
Example: 16% = Press [1] and [6].
9% = Press [0] and [9].
* If the number of print outs is set to “0”, nothing will be
displayed.
* If the target body fat ratio is set to OFF, the target body
fat ratio will not be printed out.
 Before you start a body weight management
program and set the appropriate personal
body fat ratio, please consult your doctor.
Tanita is not responsible for setting the
appropriate target body fat ratio for specific
individuals.
 For details of the desirable body fat percentage,
please refer to the Technical Notes. Male
athletes may wish to select a single digit body
fat percentage as their target. However, this is
not recommended for Standard Adults, in
particular women, who should avoid becoming
excessively lean. Always consult a doctor about
the target body fat percentage most suitable for
your body type.

lb / st.lb

CLOTHES

cm

MALE
FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Set the Target Body Fat Ratio.





 Do not step on the Weighing Platform until the
target body fat ratio setting has been
completed because the power may be
automatically turned off or the measurement
may be inaccurate.
* If you want to change the settings, please press the [CE]
key and the procedure will go back to the former step.
Please re-enter the data.
6.
WEIGHT
CLOTHES
MALE

kg
lb / st.lb
cm

WEIGHT
CLOTHES
MALE

kg
lb / st.lb
cm

FEMALE

ft.in

FEMALE

ft.in

ATHLETIC

AGE

ATHLETIC

AGE

STEP ON

% FAT

STEP ON

% FAT

14

After “88888” is displayed on the upper
portion of the screen, a flashing arrow
will appear next to Step On.

WEIGHT
CLOTHES
MALE

kg
lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

7.

Measure Weight and Impedance
When the arrow next to “STEP ON” flashes, slide the
height rod into approximate position, and then step on the
weighing platform with bare feet.
Make sure heels are placed on the posterior electrodes, and
the front part of the feet are in contact with the anterior
electrodes. To ensure the most accurate measurement,
stand up straight, and remain stable throughout the
procedure.
Caution: Do not lean against the height rod.
After weight stabilizes and is fixed on the screen,
impedance measurement is taken. This is denoted by four
“bubbles”
which appear on the bottom portion of
the LCD. As the measurement is being taken, the bubbles
will begin to disappear one by one. Actual measurement is
finished when all bubbles disappear, and the display emits
a beeping sound.



Do not step off from the weighing platform until the
final bubble has disappeared, or the display will
automatically return to
Measure the Impedance.
After the weight measurement stabilizes, “
”
is displayed on the lower portion of the screen and
an impedance measurement is taken.
As the measurement is being taken, the “
”
symbols disappear one by one.



 Do not step off the Weighing Platform until the
“
” symbols disappear completely.
 In cases when measurements of the body fat
ratio or the quantity of fat are abnormally
small or the error message (E01) is shown on
the screen, the probable reason is that the
soles of the feet and the electrodes are not in
full contact. Make sure you step on the
Weighing Platform so there is contact between
the electrodes and the soles of your feet. If the
problem is not solved this way, it is possible
that the soles of the feet have calluses and the
resistance is too great. Therefore, place about
0.5 ml of water on each of the four electrodes
where the feet touch before measurement.

Remain still on the platform during measurement.
The unit may report an error message“E-11”if constant
movement does not allow weight to lock in.
The unit may automatically turn off after an“E-11”
error message.

15

WEIGHT
CLOTHES
MALE

ATHLETIC

AGE

STEP ON

% FAT

MALE

kg
lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT
CLOTHES
MALE

kg
lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT
CLOTHES
MALE

kg
lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Measuring Height
When the arrow next to“Height”flashes, move the height
rod into place over the subject's head. At this point, the
height data may be entered in one of two ways :
・ Enter the height data by pressing the Height Confirm
Button located on the back of the Height Rod.
・ Press the CONFIRM HEIGHT key, which is located
on the control box.

cm
ft.in

WEIGHT

8.

lb / st.lb

FEMALE

CLOTHES

∼

kg

9.

■ Weight Only Function



Do not step on the platform while wearing shoes, as this may scratch the electrodes.
WEIGHT
CLOTHES

Weight and body fat results are shown on the screen after
the display emits a beep.
Step off the weighting platform.
If more than “0” print outs have been selected, results will
automatically print out after the final beep.
If you have chosen to have no print out ( pre-set printer
functions are set to “0”), the Results screen will remain for
about 30 seconds and then automatically return to Gender
and Body Type ( Step 3 ) after a short beep. Press the CE
key to erase results and proceed directly to Gender and
Body Type.
Throughout data entry, mistakes may be corrected by
pressing the CE key.
Follow the flashing arrow on the LCD for proper sequence.
If measuring units need to be changed, do so at the initial
screen by pressing the kg/lb (st.lb) key. An arrow on the
LCD will follow the selection of weighing units.
Results will not print out when the number of print outs
chosen is “0”.

cm

After a momentary display check,“0.0”will appear on the

ft.in

LCD.

ATHLETIC

AGE

If measuring units need to be changed, do so at this time

STEP ON

% FAT

by pressing the kg/lb (st.lb) key. An arrow on the LCD
will follow the selection of weighing units.
2.

WEIGHT
CLOTHES
MALE

all measuring is complete, press the
ON/OFF key to turn off the power.

lb / st.lb
cm
ft.in

ATHLETIC

AGE

STEP ON

% FAT

WEIGHT
CLOTHES
MALE

∼

kg

FEMALE

kg

Enter Clothes Weight (Optional)
This function will automatically subtract the chosen

amount of clothes weight.
a. Press the CLOTHES key. The flashing arrow
will appear next to“Clothes”.
b. Enter the clothes weight.
Press the 0 - 9 keys.

Example : 2.0kg = Press the 2

.

0 keys.

: 4.0lb = Press the 4

.

0 keys.

lb / st.lb
cm

FEMALE

ft.in

ATHLETIC

AGE

STEP ON

% FAT

Clothes weight can be entered by 0.1kg/0.2lb increments.
Remember to enter Clothes Weight to the first decimal
place, or the flashing arrow will not advance.
c. Confirm the selection by pressing the CLOTHES key.

WEIGHT

10. If

1.

FEMALE

MALE

Measurement Is Completed.

lb / st.lb

After turning on the unit, press the
WEIGHT ONLY key.

kg

CLOTHES

kg
lb / st.lb

After confirming the clothes weight, the scale will self-

cm

calibrate, and the subtracted clothes weight will appear on

FEMALE

ft.in

the LCD with a“−”sign in front of it.

ATHLETIC

AGE

STEP ON

% FAT

MALE

WEIGHT
CLOTHES

kg

3. Weight Measurement

lb / st.lb

After sliding the height rod into approximate position,

cm

step on the weighing platform. Weight will be displayed

FEMALE

ft.in

on the LCD.

ATHLETIC

AGE

When measuring is complete, Step off the weighting

STEP ON

% FAT

MALE

platform. and press the ON/OFF key to turn off the
power.
Caution: Do not lean against the height rod.

WEIGHT
CLOTHES

lb / st.lb

No printer is available when measuring weight only.

cm

*Important Note: There is no automatic weight lock

FEMALE

ft.in

function.

ATHLETIC

AGE

If body composition analysis is desired, turn the unit off

STEP ON

% FAT

and then on, using the ON/OFF key.

MALE

16

kg

17

7. Explanation of the Print Out ( Printer Model Only )
TANITA
BODY COMPOSITION
ANALYZER
TBF-215
BODY TYPE
STANDARD
GENDER
MALE
AGE
32
HEIGHT
175 cm
WEIGHT
73. 3 kg
BMI
23. 9
BMR
7266 kJ
1737 kcal
IMPEDANCE
464 Ω
FAT%
16. 0 %
FAT MASS
11. 7 kg
FFM
61. 6 kg
TBW
45. 1 kg
DESIRABLE RANGE
FAT%
8–20 %
FAT MASS
5. 5–15. 7 kg

IMPEDANCE:Impedance reflects the
body’s inherent resistance to an electrical
current. Muscle acts as a conductor of the
electrical current, adipose tissue acts as a
resistor.

FAT%:The percentage of total body
weight that is fat.

FFM:Fat Free Mass is comprised of
muscle, bone, tissue, water, and all other
fat free mass in the body.

TARGET BF% is :

TBW:Total Body Water is the amount of
water (expressed as lb, kg, or st.lb)
retained in the body. TBW is said to
comprise between 50% - 70% of total
body weight. Generally, men tend to
have higher water weight than women
due to a greater amount of muscle.

Predicted weight :
Predicted fat mass :
FAT TO LOSE:

Predicted Weight PW:
Calculated weight for the given Target
BF%.

CAUTION


Please follow these instructions to clear any paper jams from the printer assembly; be sure to turn off
the unit and unplug it from the wall outlet before beginning :
1. Remove the Paper Dispenser Cover by lifting up from the
back side.

BMI:Body Mass Index is a height to
weight ratio, and is calculated by the
following formula:
Weight (kg)
Height (m2)
Desirable Range 18.5 - 24.9

2. Remove the Printer Cover as displayed. Apply light

Printer Cover

pressure with one finger to the printer cover and lift up as
displayed.

BMR:Basal Metabolic Rate represents the
total energy expended by the body to
maintain normal functions at rest such as
respiration and circulation.

3. Raise the printer Assembly Cover as displayed.
Using the pointer finger, gently lift one end of the
automatic paper cutter, it will remain upright until
returned to the normal horizontal position. Do not

FAT MASS:Total weight of fat mass (in kg
, lb) in the body.

attempt to remove the Printer Assembly Cover.

Printer Assembly Cover

68. 4 kg

Paper Release
Lever

6. 8 kg

Consult your physician
before beginning any
weight management program. Tanita is not responsible for determining your target BF%.

When handling the printer unit, please avoid any sharp edges.

Paper Dispenser Cover

10 %

4. 9 kg

8.Trouble Shooting the Printer

4. Paper Release Lever. Lift the small black lever located on
the side of the printer assembly.
This will facilitate the clearing of any paper jams that may

Predicted Fat Mass: PFM
Caluculated fat mass for the given Target
BF%.

have occurred. The roll of printer paper must be removed
at this time. Clear any scraps of paper from the printer
assembly, as this may cause jamming in the future.
5. Be sure to return the Paper Release Lever to its proper
position.
Next, carefully move the Printer Assembly Cover to its

FAT TO LOSE/GAIN:
Calculated fat mass to lose or gain to
achieve the Predicted Weight.

proper position. Replace the Printer Cover by gently
pressing in on the side tabs of the cover as it slides into

Body Type Keys
To select the appropriate NOTE:Please refer to the Technical Notes for details.
body type
Athletic Mode is designed for individuals
meet
following
criteria:
Pleasewho
consult
yourthe
doctor
before you
start a body weight management
program.
is not old
responsible for the target body fat ratio.
・At
least Tanita
17 years
・Involved in intense aerobic exercise for ten (10) hours per week, for a minimum of 6 months
・Have a resting pulse rate of 60 beats per minute or less.



Please see Technical Notes booklet for further explanation

position.

IMPORTANT NOTE:
Failure to return the Paper Release Lever to its proper
position will result in continuous feeding of the printer
paper. If this occurs, turn off the unit by pressing the
ON/OFF key, and follow steps 1 - 5 above.
After completing steps 1 - 5, printer paper can be reloaded.
See “Loading Printer Paper” on P.9 for details. Replace the
Paper Dispenser Cover.

18

19

9. General Trouble Shooting

10. RS-232 C Interface Instructions

Listed below are common problems and simple solutions.

This instruction is for RS-232 C interface connecting the TBF-215 to a Personal Computer
(PC) or printer.

Trouble
The Unit Does Not Turn On
when the ON/OFF key is
pressed
“E-01” is Shown

“E-11” is Shown

Solution
● Please confirm that the AC adapter is properly connected to the unit.
● Make sure the AC adapter is plugged into a functioning wall outlet
● Make sure only the original Tanita AC adapter is being used.
● E - 01 is displayed when impedance shows abnormal value as compared
to height and weight.
Do not step off the platform until all of the bubbles disappear, and the
control box emits a short beep.
● Please make sure the subject was measured with bare feet, and the feet
were in contact with the electrodes.
● If the subject is wearing thin nylons or has thick calluses, place 0.5 ml of
conductant (saline, water) in the center of each electrode. Thick nylons
or socks will produce an E- 01 reading. They must be removed.
● Check the personal data for accuracy.
● E - 11 is displayed when there is a loose connection between the control
box and the weighing platform.
● Please confirm that none of connections between the scale and control
box are loose or unplugged.
● There may be excessive vibration which will disturb the measurement
process.

“E-12/13/14” are Shown

● E-12/13/14 are shown when an internal malfunction has occurred.
Please call your nearest Tanita office or dealer.

“E-15” is Shown

● When turning the unit on, the height rod may not be at its resting
position. Lower the height rod into its resting position (all the way
down), and the error message will disappear.
The [Confirm Height] key on the Control Box or the Confirm Height
Button on the Height Rod may not have been pressed, or pressed at the
wrong time. Please check that proper height was entered.

“E-16” is Shown

● Please do not step off the platform until all of the “bubbles” disappear,
and the control box emits a small beep.

No Print Out

● Please confirm number of print outs chosen is more than “0”. (see P. 10)
● Please confirm that the correct brand of paper is being used.
● Please confirm that the paper is being fed in the proper direction.
Thermal paper will only make an impression on one specially treated
side.
● Please confirm that the printer is not jammed.

“P-End” is Shown

● This means that the thermal paper has run out. Either press the CE
key to continue with no print out, or put another roll in the paper
dispenser. (see P.9).
● Please confirm that the print paper is being fed properly.
● Please check the Paper Release Lever to make sure it is in the correct
“Down” position.(see P.19)

“-----” is Shown

● The maximum weight capacity has been exceeded.

“UUU” is Shown

● Do not stand on the platform while entering personal data. Stand on the
platform only after the flashing arrow appears next to “Step On”.

FEED Key is Not Functioning

20

Please confirm the following:
● The number of copies selected is more than “0”
● There is no paper jam in the printer assembly.
FEED key is inoperative in the “Weight Only” function. Use “Body
Composition Measurement” if a printout is desired.



RS-232C Interface is data OUTPUT ONLY. The TBF-215 is not capable of receiving instructions from a PC.

Specifications
Communication Standard

EIA RS-232C Compatible

Communication Method

Asynchronous

Baud Rate

2400bps

Data Length

7bits

Parity

EVEN

Stop Bit

1bit

Signal Names and Connections
Terminal Number

Signal Name

1

※1

2

RXD

3

TXD

4

※1

5

GND

6

※1

7

※2

8

※2

9

No Connection

1

6

5

9

※ 1 : Pins No.1,4 and 6 are internal connection.
※ 2 : Pin No.7 and 8 are internal connection.

TBF

1.
2. RXD
3. TXD
4.
5. GND
6.
7.
8.

Note

PC

⃝
⃝
⃝
⃝
⃝
⃝
⃝
⃝

⃝
⃝
⃝
⃝
⃝
⃝
⃝
⃝

DCD
RXD
TXD
DTR
GND
DSR
RTS
CTS

● A Reverse Cable must be used to connect to a PC.
● A Modem Cable can not be used.

21

Transmission data

Note

The receiving PC or printer must be ready to accept output data immediately after measurement is complete.

Output Data

Body Type
Gender
Height
Weight
Impedance
Fat %
Fat Mass
FFM
TBW
Age
BMI
BMR



kg and st.lb mode
0:Standard or 2:Athletic
1:Male or 2:Female
xxx (cm)
xxx.x (kg)
xxx (Ω)
xx.x (%)
xxx.x (kg)
xxx.x (kg)
xxx.x (kg)
xx
xx.x
xxxxx (kJ)

lb mode
0:Standard or 2:Athletic
1:Male or 2:Female
xxx.x (inch)
xxx.x (lb)
xxx (Ω)
xx.x (%)
xxx.x (lb)
xxx.x (lb)
xxx.x (lb)
xx
xx.x
xxxxx (kJ)

Byte Length
1
1
2~5
3~5
3
3~4
3~5
3~5
3~5
1~2
3~4
3~5

●When measurement is taken in kg or st.lb, the data will automatically be transmitted in kg and cm.
When measurement is taken in lb the data will automatically be transmitted in lb and inch.
●When using [Weight Only] mode,data can not be transferred via the RS-232C port.
●BMR Conversion Formula : 1kcal = 4.184kJ

Output Data format
●Data is comma delimited.
●Terminal data are CR (ASCII format : /
0 DH) , LF (ASCII format : /
0 AH)
●Measurement data will be sent in the following format :

x , x , x x x , x x x . x , x x x , x x . x , x x x . x,x x x . x , x x x . x ,

x x , x x . x , x x x x x

22

23



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Create Date                     : 2006:10:08 01:17:02Z
Modify Date                     : 2006:10:08 10:18:55+09:00
Page Count                      : 12
Creation Date                   : 2006:10:08 01:17:02Z
Mod Date                        : 2006:10:08 10:18:55+09:00
Producer                        : Acrobat Distiller 5.0.5 for Macintosh
Author                          : ...c
Metadata Date                   : 2006:10:08 10:18:55+09:00
Creator                         : ...c
Title                           : TBF-215
EXIF Metadata provided by EXIF.tools

Navigation menu