F reguencg Change Instructions If there is interference with the operation of the scales (at much slower operation than normal or no operation at all) it may be uecessarry to change the frequency This can be done by following these steps I. Set all scale pads out individually (at least 12" apart). 2. Pivot the hand held antenna until the antenna is perpindicular to the flour (this is essential for communication between the pads and hand held) and turn the hand held on by pushing the "ON/OFF" button DO NOT turn the scale pads on at this time. 3. When the menu appears, select “RF Frequency" by pressing the "OK" button. Give the unit a few seconds to scan the channels and you will see numbers appear under "ACTIVITY“. Scroll the arrow down and select the fi'equency with the low- est number (least amount of interference) by pressing "OK'C (Typically 903-915 communicate the fastest.) 4. Turn the hand held otf by pushing the "ON/OFF" button for 2 seconds. 5. Turn the scale pads on by switching the battery switch on each stale pad to "ON" and press the reset button on the front of the black box.(Crreen ligtt will start blink- ing indicating power is on.) 6, Turn the hand held back on by pushing the “ON/OFF“ button. 7. When the menu appeals, select “Weigh Vehicle“ by pressing the "OK" button Give the hand held a few seconds to start communication with the scale pads. When the red lights onAL]. scale pmds are blinking and numbers appear on the scaling screen the frequency hm been changed and the scales are ready to use. If you find that one smile does not blink red afier 2 minutes, simply turn that scale off and back on and press the reset button. Communications Cable Hand Held Battery charger Hand Held Scale Display FOR FURTHER TECHNICAL ASSISTANCE CONTACT: TANNER RACING PRODUCTS 10 COOPERATIVE WAY WRIGHT CITY, MO. 83390 800-558-4112 I 636-745-7757 TannerRacing.com Mm BROS.IMGHIPE&TO0L WIRELESS RaceScale Instructions Scalin I rnction Please read all instructions prior to operating scales. 1. Set all scale pads out individually (at least 12" apart). 2. Turn on the scale pads by switching the battery switch on each scale pad to “ON“ and press the reset huuon on the front of the black box.(Green light will start blinking indicating power is on.) 3. Pivot the hand held antenna until the antenna is perpindicular to the floor (this is essential for communication between the pads and hand held) and turn the hand held on by pushing the "ON/OFF" button. 4. When the menu appears, select "Weigh Vehicle" by pressing the "OK" but- ton. Give the hand held a few sounds to start communication with the scale pads. When the red lights on M scale pads are blinking and numbers appear on the scaling screen the scales are ready to use. If you find that one scale does not blink red afier 2 minutes, simply rum that scale ofl’ and back on and press the reset button. 5. Zero the system (if necessary) by pushing the "MENU" button and selecting zero all pads. This will then display zero's in the locations selected. (this may take a few seconds) 6. Put your racecar on the scales and the weights will register, the %'s and totals will show on the display. 7. Turn the hand held off by pushing the “ON/OFF" button for 2 seconds, 8. Tum the scale pads off to conserve battery life. 9. The hand held unit contains rechargeable batterys, simply recharge by plug- ging the power adapter into the unit For best performance, charge battery for 12 hours Each scale pad contains (4) AA batterys. Button 0 eration TURNS UNITON OR OFF SELECTS DESIRED FUNCTION DlSPLAYS THE MENU TURNS BACKLIGHT ow SLROLLING ARROWS System ID / Pad Location Change If you wish to change a pad location (ex. change the RF to the LR etc.) or change the system ID, this can be done by following these steps. 1. Set all scale pads out individually (at least I2" apart). 2. Turn on the scale pads by switching the battery switch on each scale pad to "ON" and press the reset button on the lion! of the black box.(G|wn light will start blinking indicating power is m.) 3. Pivot the hand held antenna until the antmna is pcrpindicular to the floor (this is essential for communication between the pads and hand held) and turn the hand held on by pushing the "ON/OFF" button 4. When the menu is displayed on the hand held, select "SYSTEM H3", Scroll the arrow down on the word 1D and plus the right arrow over to where the name is When a character is underlined, you can change it to what- ever you wish using the up and down arrows, this will make your system unique so no one else with a wireless scale system can pick up on your "channel" and see your information. Once you are finished scroll back completely to the left and back up until the arrow is pointiong to "Save and Exit” then press "OK". You must complete step 7 to make the scales communicate. 5. Plug the communications cable into the hand held and into one scale pad. 6. Press "MENU" and select “PAD SET UP". This will allow you to change pad location and download a new system 11). Scroll the arrow down until it is pointed at the pad you are plugged into (RF,LF,RR or LR) and press “OK“. You will see a message scroll across the bottom of the screen and the message “Pad set 0K" will flash. Plug the cable into every scale pad to complete this step, each time selecting the pad you are plugged into.0nce you have completed all 4 scale pads, you must turn the [3:1de by flipping the switch to "OFF"and turn the hand held oil“ by pressing the "ON/OFF" button for 3 seconds. 7. Complete steps 1-5 of the scaling instructions and your scales are now ready to be used. 8. Turn the scale pads and hand held ot’flo conserve battery life. Thank you for your business. CAUTION: Changes or modifications not expressly approved by the party responsible for compliance could void the users authority to operate the equipment.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Create Date : 2006:01:04 13:37:03-08:00 Creator Tool : HP PrecisionScan Pro 3.0 Modify Date : 2006:01:04 13:47:17-08:00 Metadata Date : 2006:01:04 13:47:17-08:00 Producer : PDFScanLib v1.2.2 in Adobe Acrobat 7.0 Format : application/pdf Document ID : uuid:0879014d-89f7-442a-b357-656237830c92 Instance ID : uuid:734d9a45-5292-4683-a633-cfbccf3af5e6 Has XFA : No Page Count : 2 Creator : HP PrecisionScan Pro 3.0EXIF Metadata provided by EXIF.tools