Tanner Racing By Mittler Bros Mittler 50520A Transmitter User Manual manual

Tanner Racing Products By Mittler Bros. dba Mittler Corporation Transmitter manual

manual

Download: Tanner Racing By Mittler Bros Mittler 50520A Transmitter User Manual manual
Mirror Download [FCC.gov]Tanner Racing By Mittler Bros Mittler 50520A Transmitter User Manual manual
Document ID622903
Application IDdhEtb2bEOm7N34VZbPE5Ng==
Document Descriptionmanual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.98kB (74695 bits)
Date Submitted2006-01-25 00:00:00
Date Available2006-01-25 00:00:00
Creation Date2006-01-04 13:37:03
Producing SoftwarePDFScanLib v1.2.2 in Adobe Acrobat 7.0
Document Lastmod2006-01-04 13:47:17
Document Titlemanual
Document CreatorHP PrecisionScan Pro 3.0

F reguencg Change Instructions
If there is interference with the operation of the scales (at much slower operation
than normal or no operation at all) it may be uecessarry to change the frequency
This can be done by following these steps
I. Set all scale pads out individually (at least 12" apart).
2. Pivot the hand held antenna until the antenna is perpindicular to the flour (this
is essential for communication between the pads and hand held) and turn the hand
held on by pushing the "ON/OFF" button DO NOT turn the scale pads on at this
time.
3. When the menu appears, select “RF Frequency" by pressing the "OK" button.
Give the unit a few seconds to scan the channels and you will see numbers appear
under "ACTIVITY“. Scroll the arrow down and select the fi'equency with the low-
est number (least amount of interference) by pressing "OK'C (Typically 903-915
communicate the fastest.)
4. Turn the hand held otf by pushing the "ON/OFF" button for 2 seconds.
5. Turn the scale pads on by switching the battery switch on each stale pad to "ON"
and press the reset button on the front of the black box.(Crreen ligtt will start blink-
ing indicating power is on.)
6, Turn the hand held back on by pushing the “ON/OFF“ button.
7. When the menu appeals, select “Weigh Vehicle“ by pressing the "OK" button
Give the hand held a few seconds to start communication with the scale pads.
When the red lights onAL]. scale pmds are blinking and numbers appear on the
scaling screen the frequency hm been changed and the scales are ready to use. If
you find that one smile does not blink red afier 2 minutes, simply turn that scale off
and back on and press the reset button.
Communications
Cable
Hand Held
Battery charger
Hand Held
Scale Display
FOR FURTHER TECHNICAL ASSISTANCE CONTACT:
TANNER RACING PRODUCTS
10 COOPERATIVE WAY
WRIGHT CITY, MO. 83390
800-558-4112 I 636-745-7757
TannerRacing.com
Mm BROS.IMGHIPE&TO0L
WIRELESS
RaceScale
Instructions
Scalin I rnction
Please read all instructions prior to operating scales.
1. Set all scale pads out individually (at least 12" apart).
2. Turn on the scale pads by switching the battery switch on each
scale pad to “ON“ and press the reset huuon on the front of the
black box.(Green light will start blinking indicating power is on.)
3. Pivot the hand held antenna until the antenna is perpindicular to the floor
(this is essential for communication between the pads and hand held) and turn
the hand held on by pushing the "ON/OFF" button.
4. When the menu appears, select "Weigh Vehicle" by pressing the "OK" but-
ton. Give the hand held a few sounds to start communication with the scale
pads. When the red lights on M scale pads are blinking and numbers appear
on the scaling screen the scales are ready to use. If you find that one scale does
not blink red afier 2 minutes, simply rum that scale ofl’ and back on and press
the reset button.
5. Zero the system (if necessary) by pushing the "MENU" button and selecting
zero all pads. This will then display zero's in the locations selected. (this may
take a few seconds)
6. Put your racecar on the scales and the weights will register, the %'s and
totals will show on the display.
7. Turn the hand held off by pushing the “ON/OFF" button for 2 seconds,
8. Tum the scale pads off to conserve battery life.
9. The hand held unit contains rechargeable batterys, simply recharge by plug-
ging the power adapter into the unit For best performance, charge battery for
12 hours Each scale pad contains (4) AA batterys.
Button 0 eration
TURNS UNITON OR OFF
SELECTS DESIRED FUNCTION
DlSPLAYS THE MENU
TURNS BACKLIGHT ow SLROLLING ARROWS
System ID / Pad Location Change
If you wish to change a pad location (ex. change the RF to the LR etc.) or change
the system ID, this can be done by following these steps.
1. Set all scale pads out individually (at least I2" apart).
2. Turn on the scale pads by switching the battery switch on each scale pad to
"ON" and press the reset button on the lion! of the black box.(G|wn light will
start blinking indicating power is m.)
3. Pivot the hand held antenna until the antmna is pcrpindicular to the floor (this
is essential for communication between the pads and hand held) and turn the hand
held on by pushing the "ON/OFF" button
4. When the menu is displayed on the hand held, select "SYSTEM H3",
Scroll the arrow down on the word 1D and plus the right arrow over
to where the name is When a character is underlined, you can change it to what-
ever you wish using the up and down arrows, this will make your system unique
so no one else with a wireless scale system can pick up on your "channel" and
see your information. Once you are finished scroll back completely to the left and
back up until the arrow is pointiong to "Save and Exit” then press "OK". You
must complete step 7 to make the scales communicate.
5. Plug the communications cable into the hand held and into one scale pad.
6. Press "MENU" and select “PAD SET UP". This will allow you to
change pad location and download a new system 11). Scroll the arrow down until
it is pointed at the pad you are plugged into (RF,LF,RR or LR) and press “OK“.
You will see a message scroll across the bottom of the screen and the message
“Pad set 0K" will flash. Plug the cable into every scale pad to complete this step,
each time selecting the pad you are plugged into.0nce you have completed all 4
scale pads, you must turn the [3:1de by flipping the switch to "OFF"and turn the
hand held oil“ by pressing the "ON/OFF" button for 3 seconds.
7. Complete steps 1-5 of the scaling instructions and your scales are now
ready to be used.
8. Turn the scale pads and hand held ot’flo conserve battery life.
Thank you for your business.
CAUTION: Changes or modifications not expressly approved by the party
responsible for compliance could void the users authority to operate the
equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : 3.1-701
Create Date                     : 2006:01:04 13:37:03-08:00
Creator Tool                    : HP PrecisionScan Pro 3.0
Modify Date                     : 2006:01:04 13:47:17-08:00
Metadata Date                   : 2006:01:04 13:47:17-08:00
Producer                        : PDFScanLib v1.2.2 in Adobe Acrobat 7.0
Format                          : application/pdf
Document ID                     : uuid:0879014d-89f7-442a-b357-656237830c92
Instance ID                     : uuid:734d9a45-5292-4683-a633-cfbccf3af5e6
Has XFA                         : No
Page Count                      : 2
Creator                         : HP PrecisionScan Pro 3.0
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TWW-50520A

Navigation menu