TEK 561 TEKELEK LPG LEVEL MONITOR
•
The Tekelek LPG Level Monitor
measures the level of usable LPG
in your tank in 10 graduations of
the tank height.
•
We give a full 3 year warranty subject to normal conditions.
Supplied with long life no service lithium battery The warranty
becomes invalid if the sealed unit is opened.
•
Suitable for use in tanks for the storage of LPG, Propane or
Butane. Check with the manufacturer and/or supplier before
using with any other fluids.
•
The TEKELEK LPG will fit easily to most standard storage
tanks using a standard Rochester type gauge head.
•
400 meters ‘line of sight’ transmission range. Please note that
the radio transmission distance will be reduced by the proximity
of metal, e.g., steel in buildings, metal domestic appliances etc
that are effectively between the transmitter and receiver.
•
3 FITTING TRANSMITTER
This unit is only to be fitted
to a tank with a compatible
Rochester twin-site gauge
head.
•
Check that the existing tank
gauge is of the same design
as the one on the end of the
cable from the TEKELEK
LPG Monitor. Then check
and note the reading on the existing gauge and remove the gauge
display only – This is held in place with two securing screws. Dispose of
the old gauge according to local environmental guidelines.
•
Fit the new gauge to the tank using the same screws. And check that
the level on the gauge is the same as before.
• Locate the transmitter on a wall (with screws) or drain pipe (with cable
ties) in a position that is unlikely to be subject to impact causing damage
to the equipment.
• Tidy up the cable so as not to cause an obstruction.
•
-30°C to 45°C operating temperature range. Please note that
the battery operating lifetime may be reduced at higher
temperatures
Do not fit the unit to the LPG feed pipe from the tank. The unit may only
be fitted to a non LPG carrying pipe.
The TEKELEK LPG Level Monitor is now fully installed and signals
should be received every hour. After initial installation it may take one
hour for the correct level indication to be displayed on the receiver.
We reserve the right to change or improve the performance and
specification.
NOTE:
In the event of a power failure or if the receiver is switched off or moved
to a new socket:
When power returns again or unit is switched on, the receiver display
will show the top bar flashing. There is no need to repeat the
matching instruction. The top bar will continue to flash for 2 minutes,
after which time the display will show the last reading, whilst the unique
signal is located. This may take up to one hour.
INSTALLATION INSTRUCTIONS
First, Read the essential health and safety notice.
•
Tools required: Star/Philips head screwdriver
1 SETTING RECEIVER
•
The multi switches are located in a recess at the back of the
receiver above the pins. If the tank is a vertical tank then set
switch 1 on (up), if it’s horizontal set switch 1 off (down)
4 ESSENTIAL HEALTH AND SAFETY NOTICE
Manufactured by Tekelek Europe LTD,
Shannon, Ireland
Your TEKELEK LPG receiver is now
programmed to your tank height.
Part Nr: 17-5497 (EU), 17-5495 (USA)
2 MATCHING RECEIVER AND
TRANSMITTER
II 2 G Ex ib IIA
0891
You should match the receiver with the
transmitter so that the system code is
unique to your tank.
You only need to do this once.
•
•
•
•
•
•
•
Plug receiver into a suitable and
convenient electrical socket and switch
on. The display screen on the front of
the receiver will show a flashing top bar
as shown in diagram. This indicates
that the receiver is awaiting a unique
code. The bar will continue to flash for 2
minutes during which time you can
match the transmitter to the receiver.
•
Tamb: -30 to +45°C
TRAC09ATEX21221X
The Battery is not replaceable
Do not attempt to open the unit in a potentially explosive atmosphere
Periodically check that the unit is intact and securely fastened to the tank.
Check with the manufacturer on the chemical compatibility prior to use.
Do not attempt to repair this equipment. It must be returned to the
manufacturer for repair.
Warning! Electrostatic Hazard! Clean only with an antistatic cloth
FCC ID:S6T-561
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) This device must accept any interference received, including
interference that may cause undesired operation.
Hold the transmitter against the
receiver right hand side, as shown,
so that the black dots are touching
each other (important!) for about 20
seconds to allow unique code to be
transferred. Bars will increase up the
display screen. When all 10 bars are
shown they will flash to indicate that
the unique code is transferred.
Declaration:
This apparatus is designed to:- Not to give rise to physical injury or other
harm due to contact. Not to produce excessive surface temperatures, infrared, electromagnetic, ionising radiation. To have no non-electrical dangers,
when used in accordance with these user and installation instructions
Warning:
If the equipment is likely to come in to contact with aggressive substances,
then it is the responsibility of the user to take suitable precautions that
prevent it from being adversely affected, thus ensuring that the type of
protection is not compromised. Aggressive substances; - e.g. acidic liquids
or gases that may attack metals, or solvents that may affect polymeric
materials.
Note:
No modifications or additions are allowed to this equipment as to do so will
void the user’s authority to operate the equipment.
Complies with EN60079-0:2006 and EN60079-11:2007
9-5452-01
TEKELEK LPG DISPLAY
NORMAL MESSAGES
Full
Early Warning
Almost empty
Flashing triangle, no bars
No radio signal
(after waiting for two hours)
- check for correct matching procedure
- location of receiver to transmitter (try
repositioning receiver)
- moisture ingress due to seal damage
- exhausted battery
No Signal
Steady triangle.
Low battery
- The battery in the transmitter is getting
low.
- The battery is not replaceable – The unit
must be returned to the factory for
replacement – The normal service life of
the battery is 15 years.
Low battery
CHANGING BATTERY
Though the lithium battery will have a very long service life, it will
eventually become exhausted and need changing.
Do not attempt to replace the battery – simply remove the unit
from the tank and return the complete unit to the factory for
replacement. The battery can only be replaced by the
manufacturer.
For support contact: support@tekelek.ie
Tekelek Europe Ltd.
9-5452-01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 2
Producer                        : AFPL Ghostscript 7.04
Title                           : Microsoft Word - 9-5452-01 TEK 561 ATEX Installation Instructions.doc
Create Date                     : 9/1/2009 15:5:52
Author                          : MartinCallanan
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S6T561

Navigation menu