Installation Instructions
Tank Alert
Ultrasonic Liquid Level Monitor
Preparing the Tank
a) To avoid error, the TankAlert transmitter must
sit in a vertical position on top of the tank and
have a direct line of sight to the liquid level in
the tank, through to the bottom without any
interference from e.g. window configurations or
tank braces.
TankAlert monitors and displays liquid levels and
gives an alert when the level drops below 5% of
tank height. There are 2 product
types (1) Transmitter (no display
- 2 versions as in diagrams
above) + Receiver and (2)
Transmitter with Visual display
(allows user to view liquid level
at tank) + Receiver; please follow
the installation instructions for the correct type.
b) Install the supplied metal adapter into the
pre-drilled 2” NPT opening on the top of the
tank. Apply pipe sealant on the adapter thread
and tighten appropriately. For basement tanks,
temporarily place a rag/cover over the adapter
to minimize fuel odors until transmitter is
synchronized. Tanks with 1½” and 1¼” NPT
openings or European style double-wall tanks
require adapters. Do not use an extension pipe
when mounting the adapter; this can cause
inaccurate measurement and malfunction.
Activate the switch (located at back of receiver)
numbers that correlate to your tank size (see
chart at Step 9 overleaf) by using a screwdriver or
ballpoint pen to move the switches upwards to the
ON position. Activating switch 1 (the audible ring
feature), enables a bleep to indicate a low-level
reading (< 5% liquid warning).
• Plug receiver into a convenient electrical socket
and switch on.
B Transmitter (Visual or no display)
C Mounting Adapter
D Screws
Define Tank Height
Accurately measure the height of your tank from
the liquid outlet at the bottom of your tank to the
bottom of the TankAlert ultrasonic monitor. TankAlert
measures the level of usable liquid in the tank in 10
graduations of the tank height. Correct tank height
measurement is critical for accurate liquid level
display.
E Weather Seal
Fill Point
Fuel & Tank Types
TankAlert can be used on all standard steel tanks. To work
optimally, tanks must be placed on a level surface, be a
maximum height of 10 feet and be within
a 450 ft./150-meter line of sight of the
receiver.
1000mm
Bottom of Tank
Position Tank on
a Level Surface
Matching Receiver
and Transmitter for
both visual and
no-display types.
You can now link/match the receiver to the
transmitter, through getting a unique code for your
tank (this need only be done once, at installation).
A Receiver
Setting the
Switches on
the Receiver
c) Installation Help:
Avoid tank braces and tank windows.
Contents of Pack
• The display screen on the
front of the receiver will show
a flashing top bar as shown in
diagram (opposite) for up to
2 minutes indicating that the
transmitter can be matched to
the receiver during this time.
• Hold the transmitter (left side) against the
receiver’s right side so that the black dots on
each are aligned (for 20 seconds). This allows
the unique code to be transferred. During the
matching process, you will hear an audible beep
from the receiver to indicate matching is in
progress. The number of bars will increase on
the receiver display until all 10 bars are flashing
and an audible beep occurs: this indicates that
the unique code has been transferred. The setup
is now complete for the no-display type only;
the transmitter is now ready to read and transmit
liquid levels and must be placed on the tank
immediately (Step 6).
• If matching visual (LCD display) transmitter, you
MUST continue to hold the two units together
and proceed to the next stage of the matching
process (Step 5 across).
Additional Matching Step To Calibrate
Visual Transmitter to Tank Height
(TankAlert Visual ONLY)
When using TankAlert Visual, the visual transmitter
must also be calibrated to the tank dimensions. so
that liquid levels can be read at the tank as well as
in your home.
Wait for a double flash of the red light on the visual
transmitter to indicate that the tank height setting
has been stored in the transmitter. The transmitter
can now be placed on the tank.
To do this, you MUST continue to hold the
transmitter and receiver together (via the black
dots) after the ten bars are showing on the
receiver (post Step 4).
There may be one bar more or less displayed on the
visual transmitter display compared to the receiver
display when operational. This is due to the smaller
number of tank height settings that may be selected
with the transmitter screen bars compared with the
receiver switches. The bars in both displays will
accurately reflect the level in the tank.
Continue to hold the black dots together until the
visual transmitter screen goes blank. A nozzle
icon will flash in 10 seconds, indicating that the
transmitter is in ‘tank height setting’ mode. Continue
to hold as the black bars increase until the number of
black bars, according to the table below, increases to
match the height of the tank measured at step 2.
Note: if the number of bars displayed overruns
the height setting table (below), continue to
hold the black dots together until the screen
returns to blank and the nozzle flashes; re-start
the process again until the correct number of
bars appear.
When the number of bars indicates the correct tank
height, immediately separate the transmitter and the
receiver.
Tank Height
(Inches/mm)
31/800
39/1000
43/1100
47/1200
51/1300
55/1400
67/1700
79/2000
91/2300
102/2600
102/2600 to
116/3000
6
Fitting Transmitter
For tanks with pre-drilled 32mm hole:
• Remove cap from pre-drilled hole and insert
transmitter, ensuring the weather seal is securely in
place and that transmitter sits vertically.
• Tighten on to the tank with 2 stainless steel
self-tapping screws provided. Do not use longer
screws or over tighten.
For tanks with a 2”, 1½” or 1¼” BSP/NPT
gauge aperture (60mm/48mm/42mm)
• Unscrew any caps from hole; fit adapter
provided by screwing into gauge socket.
• Fit TankAlert to adapter on the tank;
ensure weather seal is in place.
• Tighten on the tank using the screws
supplied. Do not over tighten.
NOTE: Mounting Adapter supplied
must only be used.
Reading the Liquid Level
The 10-level bar graph represents the level of liquid
in your tank. The number of bars illuminated denotes
the level of liquid in the tank. You will get 2 re-fill
warnings as shown in the diagrams below.
(a) Full: Note: It may take 1
hour to get the first accurate
reading post installation.
a. Power Failure or Receiver Moved
In the event of a power failure or the receiver
being switched off, the receiver display screen
will show a top bar flashing for 2 minutes when
power is restored. The screen will then turn
blank until the unique signal is located (there
is no need to repeat the ‘black dot’ matching
instruction). This could take up to 1 hour.
c. No Ultrasonic Echo
Flashing triangle, middle
bar only. Check that
the transmitter is fitted
vertically on tank, with
no interference from a
tank wall, corrugation or
window.
(b) Early Warning (2-bars):
d. Low Battery Signal:
Constantly Flashing Warning
Light.
1. Remove transmitter from
the tank and take it into a
clean, dry environment.
Early Warning
(c) Almost Empty (1-bar).
Almost Empty
2. The battery can be
accessed by removing 4
self-tapping screws from
the base of the unit.
3. Remove the old battery
noting the orientation (+
mark facing upwards) and
replace with a new battery
(3V-CR2450)
tekelekgroup.com
info@tekelek.ie
T: +353 (0) 61 471511
5. Place the transmitter on the tank.
No need to re-match.
Please consult our website
www.tekelekgroup.com
Tank Height (ins/mm)
‘On’ Switches
(ins/mm)
‘On’ Switches
(ins/mm)
‘On’ Switches
(ins/mm)
‘On’ Switches
20/500
45/1150
1,3
71/1800
1,2,8
97/2450
1,2,3,8
22/550
1,7
47/1200
1,3,7,8
73/1850
1,2,7,8
99/2500
1,2,3,6
24/600
1,6,8
49/1250
1,3,6,8
75/1900
1,2,6,7
100/2550
1,2,3,6,7
26/650
1,6,7,8
51/1300
1,3,5
77/1950
1,2,5
102/2600
1,2,3,5,8
28/700
1,5,7
53/1350
1,3,5,7
79/2000
1,2,5,7,8
104/2650
1,2,3,5,7,8
30/750
1,5,6
55/1400
1,3,5,6,8
81/2050
1,2,5,6,8
106/2700
1,2,3,5,6,7
31/800
1,5,6,7,8
57/1450
1,3,5,6,7,8
83/2100
1,2,4
108/2750
1,2,3,4
33/850
1,4,8
59/1500
1,3,4,7
85/2150
1,2,4,7
110/2800
1,2,3,4,7,8
35/900
1,4,6
61/1550
1,3,4,6
87/2200
1,2,4,6,8
112/2850
1,2,3,4,6,8
37/950
1,4,6,7
63/1600
1,3,4,6,7,8
89/2250
1,2,4,6,7,8
114/2900
1,2,3,4,5
39/1000
1,4,5,8
65/1650
1,3,4,5,8
91/2300
1,2,4,5,7
116/3000
1,2,3,4,5,6,8
41/1050
1,4,5,7,8
67/1700
1,3,4,5,6
93/2350
1,2,4,5,6
43/1100
1,4,5,6,7
69/1750
1,3,4,5,6,7
95/2400
1,2,4,5,6,7,8
Specifications
Tank depth measurement:
Depth: 4ins/0.1m – 10 ft. /3m
(Use on tanks vented to the atmosphere)
Display:
10-bar graph level display: 10% tank height per bar.
Early warning indication (flashing tank fill) at a predetermined height above tank bottom; tank empty warning flashing red LED 		
at a predetermined height from tank bottom. Complies with FCC and UL 60335-1.
Max communication distance:
450ft. /150m in normal “line of sight” conditions.
Power supply:
Receiver: 110V +/- 10%, 60Hz.
Battery/battery life:
3-volt CR2450 lithium cell / up to 10 years.			
Wireless com:
915MHz FM transmission.
Dimensions:
Receiver: 50 x 55 x 35mm (not including aerial) Transmitter: 143 x 70 x 40mm
Max and min operating temp. (transmitter):
Operating temperature range +14˚ F to +140˚F		
Operating humidity: 0-100%
Sealed airtight unit made from PP3317 UV stabilized.
Hole size for tank fitting:
2ins. Use adapters for tanks with pre-drilled 2”, 1 ½” or 1¼” BSP/NPT 							
gauge aperture.
4. Re-assemble, ensuring
the O-Ring is undamaged
and secured in position.
Support
Multi Switch Setting Chart
Measure the vertical height of the tank from the transmitter position on top of the tank to the bottom of the tank. Read to the nearest measurement on the chart.
b. No Transmission Signal
Flashing triangle, no bars,
indicates no signal being
received. This starts
approximately 12 hours
from the last received
good signal. Re-site the
receiver closer to the
transmitter and wait for a
few hours.
If matching is not completed in the 2-minute
interval on plugging in the receiver for the first
time – then turn off the receiver at the power
point and then turn it on again to initiate a new
matching interval.
Full
Troubleshooting
Warning
It is the user’s responsibility to avoid exposing the product to aggressive substances e.g. liquids or gases that may attack
metals, or solvents that may affect polymeric materials.
•
•
•
•
•
•
•
The receiver is for indoor use only.
The receiver is a sealed unit; do not attempt to open it.
Periodically check that the unit is intact and securely fastened to the tank.
Do not attempt to repair the product.
Clean only with a damp cloth.
Do not replace batteries in a potentially explosive atmosphere.
Do not discard batteries in a pressurised container. (see symbol)
tekelekgroup.com
9-5713-01

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2015:07:24 16:43:29+01:00
Metadata Date                   : 2015:07:24 16:43:34+01:00
Modify Date                     : 2015:07:24 16:43:34+01:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:ca3e8a14-bba6-6748-832e-3254a8788c3a
Original Document ID            : xmp.did:0671F64545206811822A905D21A8E083
Document ID                     : xmp.id:6D269C015221681183D1C92321C2E089
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:B4BFF387A520681183D18F09F6DCEAB7
Derived From Document ID        : xmp.did:9B5580DCA420681183D18F09F6DCEAB7
Derived From Original Document ID: xmp.did:0671F64545206811822A905D21A8E083
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2015:07:24 16:43:29+01:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: S6T687

Navigation menu