Teleco Automation S r l TCSP240C04ALB RADIOSAFE SLAVE TRANSCEIVER WITH INTEGRATED ANTENNA 2.4 Ghz BATTERY POWERED User Manual

Teleco Automation S.r.l. RADIOSAFE SLAVE TRANSCEIVER WITH INTEGRATED ANTENNA 2.4 Ghz BATTERY POWERED

User Manual

Download: Teleco Automation S r l TCSP240C04ALB RADIOSAFE SLAVE TRANSCEIVER WITH INTEGRATED ANTENNA 2.4 Ghz BATTERY POWERED User Manual
Mirror Download [FCC.gov]Teleco Automation S r l TCSP240C04ALB RADIOSAFE SLAVE TRANSCEIVER WITH INTEGRATED ANTENNA 2.4 Ghz BATTERY POWERED User Manual
Document ID1404809
Application IDyHW/SAXv23kQ6mrPxNqj6Q==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.64kB (133006 bits)
Date Submitted2011-01-14 00:00:00
Date Available2011-01-14 00:00:00
Creation Date2010-12-23 12:28:48
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2010-12-23 12:28:50
Document TitleUser Manual
Document CreatorAdobe InDesign CS4 (6.0.6)

TELECO AUTOMATION SRL - Via dell’Artigianato, 16 - 31014 Colle Umberto (TV) ITALY
TELEPHONE: ++39.0438.388511 FAX: ++39.0438.388536
(optional) Dip-switch functions:
DIP1 OFF: selection of the 8,2KOhm safety edge, input of terminal boards 3-6
DIP1 ON: selection of (optional) infra-red safety edge (low consumption), input of
terminal boards 4-5-6
DIP2-3-4: selection of working time (see table)
Radio connection for safety devices supplied by batteries
Description
Bidirectional radio device for the connection of the safety devices in the automatic
openings sector.
The connection is carried ou between a Master device (RCSP or TVPRP868C04x)
for the motor control and a Slave device (TCSP) which is positioned on the door and
is connected to the 8,2KOhm resistive safety edge or (optional) to an infra-red low
-consumption safety edge. Every Master device can manage one Slave.
In the same installation set there can be more systems which can operate without
interference. The action ray is 10mt.
The answer time during the motion is not higher than 100ms. The Slave peripheral
devices are powered by battery and have a duration of 2 years with two batteries.
Connections:
1-2
connection of 8,2KOhm resistive safety edge. Stop function. Alarm A1.
4-5-6
connection of (optional) infra-redsafety edge (4=signal, 5=positive,
6=negative) A2
3-6
connection of 8,2KOhm resistive safety edge. Alarm A2.
Attention: if the input 1-2 ands 3-4 is not used , it is necessary to bridged with a
8,2Kohm resistance.
Technical specification of the Slave unit:
Frequency 		
2,4Ghz
Power supply		
3,6Vdc 2700mAh (lithium battery)
Dimensions		
115x65x40mm
1-Slave device (TCSP).
This device is powered by battery and it is activated by the Master unit only when
required. It sends to the Master unit the following information:
-Survival signal: it is used to verify periodically if the unit is correctly connected via
radio, the flat battery signal is also sent during the transmission.
-Flat battery signal: it is sent at every transmission.
-Motion control signal: when the Master unit receives an “autotest”request, it sends
a signal to the Slave unit in order to activate it; when the signal has been sent, there
will be an answer coming from the Slave unit in order indicate that the safety device
is functioning and so it is possible to proceed with the motion. During the motion, the
Master unit waits for receiving some signals from the Slave unit indicating the correct
functioning. If this doesn’t happen, it sends an alarm signal.
-Alarm signal: the Slave device sends an alarm signal if one of the inputs has been
activated.
-Inputs function: The Slave unit is supplied with two inputs for the safety devices
connection (one input is 8,2KOhm resistive type and the other one can be selected
between 8,2KOhm resistive type and optional infra-red type); the selection of this
input is done through the Dip1.
A working time (optional) can be selected through the Dips 2-3-4 for a maximum
time of 90 sec.; when the time is finished, an alarm signal will be sent.
Use optional low-consumption infra-red safety edges mod. TPS-S1102L.
-Programming of the Slave unit into the Master unit: this operation is done by
pushing the P1 push-button after the Master unit is “learning” mode, the successful
“learning” is indicated by two flashings of the LED.
It is possible to check the correct alignment by pushing the P1 push-button when the
Slave device has been memorized: push and hold down the P1 push-button, if the
safety edge is correctly aligned the LED will have a fixed light.
Attention:
-Never let the batteries into the TCSP safety edge if it has not been memorized in the
Master unit
-Never let the batteries into the TCSP safety edge if the Master unit has not been powered
FCC Compliance
“This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.”
Change or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
DIP1: Safety edge selection
OFF: 8.2K resistive edge
ON: Infrared edge
DIP2-3-4: Working time
DIP2
DIP3
DIP4
ON
ON
ON
ON
ON
OFF
20 sec
ON
OFF
ON
30 sec
40 sec
W. T.
10 sec
ON
OFF
OFF
OFF
ON
ON
50 sec
OFF
ON
OFF
60 sec
OFF
OFF
ON
70 sec
OFF
OFF
OFF
80 sec
Optional
P1
TCSP240C04
Optional
A1 input
A2 input
WHITE WIRE
BROWN WIRE
GREEN WIRE
Optional
Code Number:
TCSP240C04ALB
Series
Model number
TVLink RS868
Draft
Date
19-11-2010

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:12:18
Instance ID                     : uuid:aa415749-cc68-472b-9fd6-739ddf98b3e9
Document ID                     : xmp.did:B5B59E9EB42DDF11B9708D9D1F33E681
Original Document ID            : adobe:docid:indd:41eac041-1ab5-11de-a115-f3fa2b336e06
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:B4B59E9EB42DDF11B9708D9D1F33E681
Derived From Document ID        : adobe:docid:indd:41eac041-1ab5-11de-a115-f3fa2b336e06
Derived From Original Document ID: adobe:docid:indd:41eac041-1ab5-11de-a115-f3fa2b336e06
Derived From Rendition Class    : default
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:A1BC7E4E91A7DE119A70C601D2CC70CA, xmp.iid:A2BC7E4E91A7DE119A70C601D2CC70CA, xmp.iid:F6AC4B8D5D07DF1184DC9100CDE1F57E, xmp.iid:B4B59E9EB42DDF11B9708D9D1F33E681, xmp.iid:B5B59E9EB42DDF11B9708D9D1F33E681, xmp.iid:B8B59E9EB42DDF11B9708D9D1F33E681, xmp.iid:5FFFA442C2F3DF118D41D13C5412761B, xmp.iid:62FFA442C2F3DF118D41D13C5412761B, xmp.iid:AAFC26119F0DE0118598DB3246863F54
History When                    : 2009:09:22 18:04:44+02:00, 2009:09:22 18:04:44+02:00, 2010:01:22 14:53:42+01:00, 2010:03:12 10:05:56+01:00, 2010:03:12 10:05:56+01:00, 2010:03:12 10:11:17+01:00, 2010:11:19 10:49:11+01:00, 2010:11:19 18:05:36+01:00, 2010:12:22 10:14:48+01:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0
History Changed                 : /, /metadata, /, /metadata, /;/metadata, /, /, /, /
Create Date                     : 2010:12:23 12:28:48+01:00
Modify Date                     : 2010:12:23 12:28:50+01:00
Metadata Date                   : 2010:12:23 12:28:50+01:00
Creator Tool                    : Adobe InDesign CS4 (6.0.6)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10929 bytes, use -b option to extract)
Doc Change Count                : 235
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.0
Trapped                         : False
Page Count                      : 1
Creator                         : Adobe InDesign CS4 (6.0.6)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P59TCSP240C04ALB

Navigation menu