Teledyne Dollhouse 400E Users Manual TECHNICAL PHOTOMETRIC OZONE ANALYZER
400E to the manual 768cbdc8-05f9-4f82-8454-32f24958ebc0
2015-02-03
: Teledyne Teledyne-Dollhouse-400E-Users-Manual-464455 teledyne-dollhouse-400e-users-manual-464455 teledyne pdf
Open the PDF directly: View PDF
Page Count: 324 [warning: Documents this large are best viewed by clicking the View PDF Link!]
- TECHNICAL MANUAL MODEL 400E PHOTOMETRIC OZONE ANALYZER
- TABLE OF CONTENTS
- 1. INTRODUCTION
- 2. SPECIFICATIONS, APPROVALS AND WARRANTY
- 3. GETTING STARTED
- 3.1. MODEL 400E ANALYZER LAYOUT
- 3.2. UNPACKING THE M400E ANALYZER
- 3.3. ELECTRICAL CONNECTIONS
- 3.4. PNENUMATIC CONNECTIONS
- 3.5. INITIAL OPERATION
- 3.6. INITIAL CALIBRATION OF THE M400E ANALYZER
- 3.7. CONFIGURING THE INTERNAL ZERO/SPAN OPTION (IZS)
- 4. FREQUENTLY ASKED QUESTIONS AND GLOSSARY
- 5. OPTIONAL HARDWARE AND SOFTWARE
- 6. BASIC OPERATION OF THE M400E ANALYZER
- 6.1. OVERVIEW OF OPERATING MODES
- 6.2. SAMPLE MODE
- 6.3. CALIBRATION MODE
- 6.4. SETUP MODE
- 6.4.1. SETUP ( CFG: CONFIGURATION INFORMATION
- 6.4.2. SETUP ( PASS: ENABLING/DISABLING PASSWORDS
- 6.4.3. SETUP ( CLK: SETTING THE M400E ANALYZER’S INTERNAL CLOCK
- 6.4.4. SETUP ( RNGE: ANALOG OUTPUT REPORTING RANGE CONFIGURATION
- 6.4.4.1. Physical Range versus Analog Output Reporting Ranges
- 6.4.4.2. Analog Output Ranges for O3 Concentration
- 6.4.4.3. RNGE ( MODE ( SNGL: Configuring the M400E analyzer for Single Range Mode
- 6.4.4.4. RNGE ( MODE ( DUAL: Configuring the M400E analyzer for Dual Range Mode
- 6.4.4.5. RNGE ( MODE ( AUTO: Configuring the M400E analyzer for Auto Range Mode
- 6.4.4.6. SETUP ( RNGE ( UNIT: Setting the Reporting range Unit Type
- 7. ADVANCED FEATURES OF THE M400E ANALYZER
- 7.1. USING USING THE DATA ACQUISITION SYSTEM (IDAS)
- 7.1.1. IDAS STATUS
- 7.1.2. IDAS STRUCTURE
- 7.1.3. IDAS CHANNELS
- 7.1.4. SETUP (DAS (VIEW: VIEWING IDAS CHANNELS AND INDIVIDUAL RECORDS
- 7.1.5. SETUP (DAS (EDIT: ACCESSING THE IDAS EDIT MODE
- 7.1.5.1. Editing iDAS Data Channel Names
- 7.1.5.2. Editing iDAS Triggering Events
- 7.1.5.3. Editing iDAS Parameters
- 7.1.5.4. Editing Sample Period and Report Period
- 7.1.5.5. Report periods in Progress when Instrument Is Powered Off
- 7.1.5.6. Editing the Number of Records
- 7.1.5.7. RS-232 Report Function
- 7.1.5.8. Enabling / Disabling the HOLDOFF Feature
- 7.1.5.9. The Compact Report Feature
- 7.1.5.10. The Starting Date Feature
- 7.1.6. DISABLING/ENABLING DATA CHANNELS
- 7.1.7. REMOTE IDAS CONFIGURATION
- 7.2. SETUP ( MORE ( VARS: INTERNAL VARIABLES (VARS)
- 7.3. SETUP ( MORE ( DIAG :THE DIAGNOSTIC MENU
- 7.4. USING THE MODEL 400E ANALYZER’S ANALOG OUTPUTS.
- 7.4.1. ADJUSTING & CALIBRATING THE ANALOG OUTPUT SIGNALS
- 7.4.2. CALIBRATION OF THE ANALOG OUTPUTS
- 7.4.3. ANALOG OUTPUT VOLTAGE / CURRENT RANGE SELECTION
- 7.4.4. TURNING AN ANALOG OUTPUT OVER-RANGE FEATURE ON/OFF
- 7.4.5. ADDING A RECORDER OFFSET TO AN ANALOG OUTPUT
- 7.4.6. SELECTING A TEST CHANNEL FUNCTION FOR OUTPUT A4
- 7.4.7. AIN CALIBRATION
- 7.1. USING USING THE DATA ACQUISITION SYSTEM (IDAS)
- 8. REMOTE OPERATION OF THE M400E
- 8.1. USING THE ANALYSER’S COMMUNICATION PORTS
- 8.2. REMOTE ACCESS BY MODEM
- 8.3. RS-485 CONFIGURATION OF COM2
- 8.4. REMOTE ACCESS VIA THE ETHERNET
- 8.5. USING THE M400E WITH A HESSEN PROTOCOL NETWORK
- 8.5.1. GENERAL OVERVIEW OF HESSEN PROTOCOL
- 8.5.2. HESSEN COMM PORT CONFIGURATION
- 8.5.3. ACTIVATING HESSEN PROTOCOL
- 8.5.4. SELECTING A HESSEN PROTOCOL TYPE
- 8.5.5. SETTING THE HESSEN PROTOCOL RESPONSE MODE
- 8.5.6. HESSEN PROTOCOL GAS LIST ENTRIES
- 8.5.7. SETTING HESSEN PROTOCOL STATUS FLAGS
- 8.5.8. INSTRUMENT ID CODE
- 8.6. APICOM REMOTE CONTROL PROGRAM
- 9. M400E CALIBRATION PROCEDURES
- 9.1. BEFORE CALIBRATION
- 9.2. BASIC MANUAL CALIBRATION CHECKS AND CALIBRATION OF THE M400E ANALYZER
- 9.3. MANUAL CALIBRATION CHECK AND CALIBRATION WITH VALVE OPTIONS INSTALLED
- 9.4. AUTOMATIC ZERO/SPAN CAL/CHECK (AUTOCAL)
- 9.5. O3 PHOTOMETER ELECTRONIC CALIBRATION
- 9.6. CALIBRATION THE IZS OPTION O3 GENERATOR
- 10. EPA PROTOCOL CALIBRATION
- 10.1.1. M400E CALIBRATION – GENERAL GUIDELINES
- 10.1.2. CALIBRATION EQUIPMENT, SUPPLIES, AND EXPENDABLES
- 10.1.3. CALIBRATION GAS AND ZERO AIR SOURCES
- 10.1.4. RECOMMENDED STANDARDS FOR ESTABLISHING TRACEABILITY
- 10.1.5. CALIBRATION FREQUENCY
- 10.1.6. DATA RECORDING DEVICE
- 10.1.7. RECORD KEEPING
- 10.2. LEVEL 1 CALIBRATIONS VERSUS LEVEL 2 CHECKS
- 10.3. MULTIPOINT CALIBRATION
- 10.4. AUDITING PROCEDURES
- 10.5. SUMMARY OF QUALITY ASSURANCE CHECKS
- 10.6. REFERENCES
- 11. THEORY OF OPERATION
- 12. MAINTENANCE SCHEDULE & PROCEDURES
- 12.1. PREDICTING FAILURES USING THE TEST FUNCTIONS
- 12.2. MAINTENANCE SCHEDULE
- 12.3. MAINTENANCE PROCEDURES
- 12.3.1. REPLACING THE SAMPLE PARTICULATE FILTER
- 12.3.2. REBUILDING THE SAMPLE PUMP
- 12.3.3. REPLACING THE IZS OPTION ZERO AIR SCRUBBER
- 12.3.4. PERFORMING LEAK CHECKS
- 12.3.5. PERFORMING A SAMPLE FLOW CHECK
- 12.3.6. MAINTENANCE OF THE PHOTOMETER ABSORPTION TUBE
- 12.3.7. ADJUSTMENT OR REPLACEMENT OF OPTIONAL IZS OZONE GENERATOR UV LAMP
- 13. GENERAL TROUBLESHOOTING & REPAIR OF THE M400E ANALYZER
- 13.1. GENERAL TROUBLESHOOTING
- 13.2. USING THE ANALOG OUTPUT TEST CHANNEL
- 13.3. USING THE INTERNAL ELECTRONIC STATUS LEDS
- 13.4. GAS FLOW PROBLEMS
- 13.5. CALIBRATION PROBLEMS
- 13.6. OTHER PERFORMANCE PROBLEMS
- 13.7. SUBSYSTEM CHECKOUT
- 13.8. TROUBLE SHOOTING THE PHOTOMETER
- 13.9. TROUBLE SHOOTING THE IZS OPTIONS O3 GENERATOR
- 13.10. REPAIR PROCEDURES
- 13.11. TECHNICAL ASSISTANCE
- 14. A PRIMER ON ELECTRO-STATIC DISCHARGE
- APPENDICES
- APPENDIX A – Software Version-Specific Documentation
- APPENDIX A-1: Model 400E Software Menu Trees
- Figure A-1: Basic Sample Display Menu without Options
- Figure A-1: Basic Sample Display Menu with Options
- Figure A-2: Primary Setup Menu (Except iDAS)
- Figure A-3: Primary Setup Menu (iDAS)
- Figure A-4: Secondary Setup Menu (COMM & VARS)
- Figure A-5: Secondary Setup Menu (HESSEN)
- Figure A-6: Secondary Setup Menu (DIAG & O3)
- APPENDIX A-2: Model 400E Setup Variables Available Via Serial I/O
- APPENDIX A-3: Model 400E Warnings and Test Measurements Via Serial I/O
- APPENDIX A-4: Model 400E Signal I/O Definitions
- APPENDIX A-5: Model 400E iDAS Functions
- APPENDIX A-1: Model 400E Software Menu Trees
- APPENDIX B – M400E Spare Parts and Expendables
- APPENDIX C - Model M400E Manual Warranty/Repair Questionnaire
- APPENDIX D – ELECTRONIC SCHEMATICS
- 04396Interconnect Diagram, M400E
- 04406Interconnect List, M400E
- 05703PCA, 05702, Motherboard, E-Series Gen 4
- 03632PCA 03631, 0-20mA Driver
- 04259PCA 04258, Keyboard & Display Driver
- 04354PCA 04003, Pressure/Flow Transducer Interface
- 04420PCA 04120, UV Detector Preamp
- 04421PCA 04166, UV Lamp Power Supply
- 04422PCA 04144, DC Heater/Thermistor
- 03956PCA 03955-0100, Relay Board
- 04468PCA, 04467, Analog Output Series Res
- APPENDIX A – Software Version-Specific Documentation