Telemedic MUMS-002 Multi-users, multi-sensors User Manual sstBB4

Telemedic Inc. Multi-users, multi-sensors sstBB4

User Manual

Download: Telemedic MUMS-002 Multi-users, multi-sensors User Manual sstBB4
Mirror Download [FCC.gov]Telemedic MUMS-002 Multi-users, multi-sensors User Manual sstBB4
Document ID1297216
Application IDttienOV3X0mSmtEmr304yQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize59.42kB (742711 bits)
Date Submitted2010-06-16 00:00:00
Date Available2010-06-21 00:00:00
Creation Date2010-05-18 09:05:54
Producing SoftwareFoxit PDF Creator Version 2.0.0 build 0725
Document Lastmod0000-00-00 00:00:00
Document TitleMicrosoft Word - sstBB4.doc
Document CreatorC:\Program Files\Microsoft Office\OFFICE11\WINWORD.EXE
Document Author: arichard

Operator’s Manual
6700, avenue Choquette bur. 200
St-Hyacinthe (Québec)
J2S 8L1
Tél: 1-866-550-1414
Fax: (450) 250-1416
www.telemedic.ca
Multi User Multi Sensors
Model MUMS-002
Copyright © 2010 TéléMédic Inc. All rights reserved.
This equipment is protected by the Canadian copyright laws. It cannot be reproduced, distributed or modified in any ways by other entities than
TéléMédic, except under written consent by TéléMédic.
All the requisite efforts have been done to ensure that the information contained in this document was complete and precise at the moment of printing. However,
the information can be modified without notice.
Declaration of conformity
This device is registered as CSA International certified. To see the certificates of official declaration, consult the online documentation on TéléMédic’s website:
http : //www.telemedic.ca
This device complies with Industry Canada’s low power radio devices norms RSS-210. Certification number: 6418A-MUMS002
This device complies with the FCC (Federal Communications Commission) intentional radio frequencies transmission.
Identification number: FCC ID : T3W-MUMS-002
Trademark
Vie-Gie Med is registered trademarks. Other brands and products names mentioned in this document are properties of the respective holders.
Ordering information
You can order updates of this document directly on TéléMédic's website: http://www.telemedic.ca .
Comments
TéléMédic appreciates your comments relating to this manual. Please send your comments directly to info@telemedic.ca.
Support
For all technical questions or defectiveness, please contact TéléMédic’s user support service at 1-866-550-1414 or at info@telemedic.ca
Meaning of symbols used in this manual:
Warning: Failure to these instructions may lead to unexpected operation or
defects of the system.
Important: Important element to consider in the use of this device.
Meaning of device symbols:
Warning: Consult accompanying documents. This manual and the associated
sections on TéléMédic’s website (see manual for references) should be consulted
before using this device.
This equipment complies with general requirements for safety of medical electrical
equipment CAN/CSA C22.2 No.601.1 and CAN/CSA C22.2 No.60601-1-1, UL
2601-1. This equipment also complies with electromagnetic compatibility
requirements for medical electrical equipment CAN/CSA C22.2 No 60601-1-2
This device complies with FCC (Federal Communications Commission) rules part
15 (Radio frequency devices) for the United States.
This equipment includes radio frequency transmitter which generate non-ionizing
radiation.
Table of contain
The Multi User Multi Sensors, MUMS ............................................................................................................. 4
Indications for use............................................................................................................................................ 4
Main components ............................................................................................................................................ 4
Installation....................................................................................................................................................... 6
Turning on the unit....................................................................................................................................... 6
MUMS indicators ............................................................................................................................................ 6
Language selection .......................................................................................................................................... 7
Acquiring vital signs session ............................................................................................................................ 8
Emergency stop ............................................................................................................................................... 8
Server data transmission .................................................................................................................................. 8
Battery recharge (available only on model MUMS-002)................................................................................... 8
Precautionary measures.................................................................................................................................... 8
Functional preventive check-ups ...................................................................................................................... 9
Maintenance .................................................................................................................................................... 9
Optimal operating performance........................................................................................................................ 9
Warranty ........................................................................................................................................................... 9
Technical support ............................................................................................................................................ 10
Conformity....................................................................................................................................................... 10
Technical specifications ................................................................................................................................... 11
Pictures list
Picture 1: Components of MUMS ........................................................................................................................ 4
Picture 2: Accessories port of MUMS .................................................................................................................. 5
Table list
Table 1 List of supported optional medical equipment.......................................................................................... 6
Table 2 List of accessories on the MUMS ............................................................................................................ 6
The Multi User Multi Sensors, MUMS
Indications for use
The MUMS is a device that acquires vital signs using internal devices and external devices. Vital signs
acquired are displayed on the device and then transmitted to a database on a server accessible on the
Internet.
This device can be deployed to several locations. To ensure that data can be transmitted to the server,
the device must operate in conjunction with a communication base E90 from TéléMédic. Once vital
signs acquired, the MUMS send those in the secure way to communication base TéléMédic E90. This
communication base sends those to server database using a network connection or through a phone
line.
Main components
Picture 1: Components of MUMS
Picture 2: Accessories port of MUMS
Installation
The MUMS is compatible only with optional medical devices mentioned in Table 1 and the permanent
and replaceable accessories in Table 2.
•
•
•
With the Table 1, choose the appropriate cable for your medical device.
Connect the flat cable into the external devices port (number 2 of the Picture 2) under the MUMS
unit. Note that this connector must be connected in a particular orientation. The two small
screws on the connector must be oriented toward the bottom of the cavity so that they are not
visible once the connector is connected. Make sure that the small locks on each side of the
connector are locked. It is necessary to secure the accessory cables by placing them in the right
lock sluts that are made for this purpose.
Then connect the other end of the cable into the appropriate connector on your external devices
(You can refer to the manufacturer's user manual of your equipment if necessary).
Device Type
Model
Manufacturer
Scale and
blood glucose
monitor
Scale
Blood glucose
monitor
UC-321P et
OneTouch
Ultra 2
UC-321P
OneTouch
Ultra 2
A&D et
LifeScan
A&D
LifeScan
Appropriate
TéléMédic cable
31-043
31-044
31-042
Note
Scale
and
blood glucose setup
Scale only
Blood glucose monitor only
Table 1 List of supported optional medical equipment
Accessories
Model
Manufacturer
Pulse
oxymeter
finger clip
Blood pressure
monitor
cuff,
medium
Blood pressure
monitor
cuff,
small
Blood pressure
monitor
cuff,
large
8000AA-1
Nonin Medical
TéléMédic part
number
50-11019
UA-280
A&D
50-81003
Included with the MUMS
unit
UA-279
A&D
50-81004
Supply on demand
UA-281
A&D
50-81002
Supply on demand
Note
Included with the MUMS
unit
Table 2 List of accessories on the MUMS
Turning on the unit
Connect the power supply provided by TéléMédic (TéléMédic Part no 50-15007 / Manufacturer CUI
Inc. # EPS090250U-P5P-KH) to the MUMS power input connector (number 6 of the Picture 1). The
power supply should then be connected to a standard electrical outlet (120V, 60Hz).
Turn on the power switch at the back of the MUMS (number 7 of the Picture 1). The MUMS should be
ready to use in few seconds.
MUMS indicators
Low battery
indicator
Battery led level indicator (number 2 of the Picture 1) (Available on the MUMS-002
only)
•
LCD display
7 segments
display
Turns on and stays on until the low battery condition is true. (see the
section on battery recharge at the page 8)
Display instructions to help user in his MUMS session (number 1 of the Picture 1).
• Always on.
• Guide the patient in taking is vital signs.
Display the value of vital signs (number 3 of the Picture 1).
•
•
•
•
•
Turn on when the vital sign are toke and ready to display.
« Dash, void, dash » means that the acquisition is cancelled.
« Void, dash, void » means that the acquisition is not toke in time.
« Numerical value » means that the vital sign is acquired with success
and the value of this vital sign.
If the message “EXX” is displayed, that means that some internal error is
occurred. In this case, you should turn off the MUMS unit and then turn it
on to take another MUMS session.
Identification
Place where to put the identification key (number 4 of the Picture 1).
Key port
• The key port indicator flashes when the user must insert or retire his
identification key.
The MUMS indicates a fault when a constant and periodic noise is emitted. In this case, please contact
the technical support of TéléMédic.
Language selection
It is possible to change the language of the MUMS by fallowing theses steps:
•
•
•
•
•
•
Turn off the MUMS by putting the power switch at the “OFF” position (number 7 of the Picture 1).
Hold down the button (number 5 of the Picture 1).
Turn on the device by putting the power switch at “ON” (number 7 of the Picture 1).
Hold down the button (number 5 of the Picture 1) until the menu of language selection appears.
Press the button (number 5 of the Picture 1) to toggle between “French” and “English”.
When the arrow point on your choice, release the button (number 5 of the Picture 1) and wait
until the MUMS start up with the selected language.
Acquiring vital signs session
When the power switch (number 7 of the Picture 1) is turned ON, the MUMS run a short self
initialization. When the initialization is done, the unit is ready to acquire vital signs. To perform a
session of acquiring vital signs, follow the instructions that are displayed on the LCD (number 1 of the
Picture 1).
A complete MUMS session with all externals devices and accessories connected to it (number 1, 2 and
3 of the Picture 2) can be resuming with those steps:
1. Insert your identification key (number 8 of the Picture 1) in the identification key port (number 4
of the Picture 1) when the MUMS asking for.
2. Fallow the instructions on the LCD display (number 1 of the Picture 1) to take the blood glucose.
Press the button (number 5 of the Picture 1) if you want to cancel this step.
3. Fallow the instructions on the LCD display (number 1 of the Picture 1) to take your weight if the
weight scale is connected to the MUMS. Press the button (number 5 of the Picture 1) if you want
to cancel this step.
4. Install the blood pressure monitor cuff on your arm by fallowing instructions stamped on it
(number 9 of the Picture 1).
5. Install the pulse oxymeter finger clip (number 10 of the Picture 1) on your finger tip.
6. Lay down your arm on the table at the height of your heart and don’t move this arm.
7. Press the button (number 5 of the Picture 1) to start the measure of the blood pressure monitor
and the pulse oxymeter. Stay still for all duration of the acquisition.
8. Remove the blood pressure monitor cuff (number 9 of the Picture 1) and the pulse oxymeter
finger clip (number 10 of the Picture 1) when the MUMS asked for it.
9. Remove your identification key (number 8 of the Picture 1) and wait data transferred to the
communication base E90.
10. The MUMS comes back at the beginning of his program, ready to proceed to another acquiring
session.
Emergency stop
During the blood pressure measure, if you feel uncomfortable, you can press the button (number 5 of
the Picture 1) to stop the blood pressure measuring.
Server data transmission
The transmission of data to the server is done automatically at the end of the session. If the server can’t
be reached, then the vital signs are stored and kept in the unit's internal memory until the link with the
communication base E90 or the link with is restored. It is possible to force a transfer of data to the
server. Once the MUMS is turned on and waiting for an identification key (number 8 of the Picture 1),
press the button (number 5 of the Picture 1) and hold it until the symbol "?" becomes the TéléMédic
logo. Wait a few seconds to allow the MUMS device complete it data transfer.
Battery recharge (available only on model MUMS-002)
The MUMS-002 to an internal battery backup that allows it to operate without external power for a
period of approximately 5 hours of continuous use.
The charging time for full recharge of the battery is 4 hours. Charging the battery should be performed
when the low battery indicator is on, (number 2 of the Picture 1)
Precautionary measures
The MUMS unit is a precise scientific device that requires some basic precautions during use.
Following the advice listed below will ensure your MUMS unit longevity, durability and optimal operating
performance.
Never:
• Open or dismantle the device.
• Hit or throw the device.
• Subject the device to sudden temperature changes.
• Put the device in an area exposed to high temperature, high moisture or dusty contents.
• Clean the device with a vaporizing liquid, solvent, or detergent.
• Immerse the device.
Functional preventive check-ups
To ensure your MUMS optimal operating performance, do the following check-ups:
•
•
The power switch (number 7 of the Picture 1)has to be up;
Make sure the power supply is connected to a standard electrical outlet (120V, 60Hz) and that
the plug is connected to the MUMS power input connector (number 6 of the Picture 1).
Maintenance
•
Use a soft lightly damp cloth.
Optimal operating performance
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. This medical equipment needs special precautions regarding
electromagnetic compatibility (EMC). Installation and services shall take care of following precautions:
These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If the
equipment does cause harmful interference to radio or television reception, which can be determined
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
•
•
•
•
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help
Using other than those provided or specified by TéléMédic may affect the electromagnetic compatibility.
For installation adjacent, stacked or very close to electrical equipment, it is important to verify operation
of either product. For MUMS refer to functional preventive check-ups above. For the other equipment
refer to the manufacturer operating manual.
Also, portable and mobile RF communication equipment may affect the MUMS.
Warranty
This equipment is guaranteed for the period of 1 year after the date of purchase against manufacturing
defects when returned along with the proof of date of purchase. During this period, the unit will be
repaired or replaced free of charge if the failure is attributable to fault design or manufacture. This
warranty does not cover damage or malfunction caused by improper handling or use contrary to the
instruction in this manual.
Technical support
If you detect or suspect any malfunction or failure of the MUMS, or if you have questions about its
installation or use, please contact TéléMédic's technical support at 1-866-550-1414 or visit our website
at www.telemedic.ca.
Conformity
This device complies with Part 15 of the FCC rules (US) and RSS-210 (Canada). Operation is subject
to the following two conditions: (1) this device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by TéléMédic could void the user’s authority to
operate the equipment.
Technical specifications
•
Radio communication:
Transmission power = 750μW (-1.25 dBm)
Transmission range = 100 metres/328 ft.
Frequency = 916MHz (frequency band ISM)
TéléMédic's proprietary protocol
•
Standby generation:
•
•
•
•
Power consumption:
Memory capacity:
Data retention:
Inputs/Outputs:
Rechargeable internal batteries 3.7V Lithium Ion
Autonomy = 5 hours
Batteries are not intended
to be changed by the operator.
9W when battery is in charge
Up to 20000 vital signs values
40 years
Communication port for accessories
(number 1 and 3 of the Picture 2).
Communications port for external devices
(number 2 of the Picture 2).
Identification key port (number 4 of the Picture 1).
•
•
•
Dimensions:
Weight:
Temperature:
•
•
Humidity:
Security:
28 cm x 19 cm x 9 cm /11 in x 7.5 in x 3.5 in
1.5kg / 3.3lbs.
Operation = 10-35 ºC (50-95 ºF)
Storage = 5-40 ºC (41-104 ºF)
Operation = 20-80% / Storage = 15-90%
CAN/CSA C22.2 No.601.1, CAN/CSA C22.2 No.60601-1-1,
CAN/CSA C22.2 No.60601-1-2 et UL 2601-1.
Guidance and manufacturer’s declaration – electromagnetic emissions
The MUMS is for use in the electromagnetic environment specified below. The customer or the user of the MUMS
should assure that it is used in such an environment
Emissions test
Compliance
Electromagnetic environment - guidance
GROUP 1
The MUMS uses RF energy only for its internal function.
Therefore, its RF emissions are very low and are note likely
to cause any interference in nearby electronic equipment.
RF emissions
CISPR 11
RF emissions
Class B
CISPR 11
Harmonic emissions
The MUMS is suitable for use in all establishments,
including domestic establishments and those directly
connected to the public low-voltage power supply network
that supplies buildings used for domestic purposes.
Not applicable
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
Complies
IEC 61000-3-3
Guidance and manufacturer’s declaration – electromagnetic immunity
The unit MUMS is intended to be used in the electromagnetic environment specified below. The
customer or the user of the MUMS unit should assure that it is used in such an environment.
Immunity test
IEC 60601
test level
Compliance level
Electrostatic
discharge (ESD)
±6 kV contact
±4 kV contact
IEC 61000-4-2
±8 kV air
±4 kV air
Electrical fast
transient/burst
IEC 61000-4-4
±2 kV for power supply
lines
±1 kV for power supply
lines
±1 kV for input/output
lines
There is no I/O
±1 kV differential mode
±1 kV differential mode
±2 kV common mode
±2 kV common mode
<5 % U T
(>95 % dip in U T)
For 0,5 cycle
<5 % U T
(>95 % dip in U T)
For 0,5 cycle
40 % U T
(60 % dip in U T)
For 5 cycle
40 % U T
(60 % dip in U T)
For 5 cycle
70 % U T
(30 % dip in U T)
For 25 cycle
70 % U T
(30 % dip in U T)
For 25 cycle
<5 % U T
(>95 % dip in U T)
For 5 s
3 a/m
<5 % U T
(>95 % dip in U T)
For 5 s
3 a/m
Surge
IEC 61000-4-5
Voltage dips, short
interruptions and
voltage variations on
power supply input
lines
IEC 61000-4-11
Power frequency
(50/60 Hz)
Magnetic field
IEC 61000-4-8
NOTE UT is the a.c. mains voltage prior to application of the test level.
12
Electromagnetic environment guidance
Floors should be wood, concrete or
ceramic tile. If floors are covered with
synthetic material, the relative humidity
should be at least 30 %.
Mains power quality should be that of a
typical
commercial
or
hospital
environment. It is recommended that the
MUMS be used with a surge protector if
the user uses the MUMS where the
power quality is lower.
Mains power quality should be that of a
typical
commercial
or
hospital
environment. It is recommended that the
MUMS be used with a surge protector if
the user uses the MUMS where the
power quality is lower.
Mains power quality should be that of a
typical
commercial
or
hospital
environment. If the user of the MUMS
requires continued operation during
power mains interruptions, it is
recommended that the MUMS be
powered from an uninterruptible power
supply or a battery.
Guidance and manufacturer’s declaration – electromagnetic immunity
The MUMS is intended for use in the electromagnetic environment specified below. The customer or the user of the MUMS should assure
that it is used in such an environment.
Immunity test
IEC 60601 test
Compliance level
Electromagnetic environment – guidance
level
Portable and mobile RF communications equipment should be
used no closer to any part of the MUMS, including cables, than
the recommended separation distance calculated from the
equation applicable to the frequency of the transmitter.
Conducted RF IEC
61000-4-6
3 Vrms
150 kHz to 80 MHz
3 Vrms
Radiated RF IEC
61000-4-3
3 V/m 80 MHz to
2,5 GHz
3 V/m
Recommended separation distance
d = 1,2√P d = 1,2√P 80 MHz to 800 MHz
d = 2,3√P 800 MHz to 2,5 GHz
Where P is the maximum output power rating of the transmitter
in watts (W) according to the transmitter manufacturer and d is
the recommended separation distance in metres (m). Field
strengths from fixed RF transmitters, as determined by an
electromagnetic site survey (a), should be less than the
compliance level in each frequency range.(b) Interference may
occur in the vicinity of equipment marked with the following
symbol:
NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations.
Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.
(a) Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur
radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic
environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location
in which the MUMS is used exceeds the applicable RF compliance level above, the MUMS should be observed to verify normal operation. If
abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the MUMS.
(b) Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m.
Recommended separation distances between portable and mobile RF communications equipment and the
MUMS
The MUMS is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
The customer or the user of the MUMS can help prevent electromagnetic interference by maintaining a minimum
distance between portable and mobile RF communications equipment (transmitters) and the MUMS as
recommended below, according to the maximum output power of the communications equipment.
Separation distance according to frequency of transmitter m
Rated maximum output power
150 kHz to 80 MHz
80 MHz to 800 MHz
800 MHz to 2,5 GHz
of transmitter W
1,2√P
1,2√P
2,3√P
0,01
0,12
0,12
0,23
0,1
0,38
0,38
0,73
1,2
1,2
2,3
10
3,8
3,8
7,3
100
12
12
23
For transmitters rated at a maximum output power not listed above, the recommended separation distance d in
metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the
maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.
NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and
reflection from structures, objects and people.
13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 13
Author                          : arichard
Create Date                     : 2010:05:18 09:05:54-04:00
Creator                         : C:\Program Files\Microsoft Office\OFFICE11\WINWORD.EXE
Producer                        : Foxit PDF Creator Version 2.0.0 build 0725
Title                           : Microsoft Word - sstBB4.doc
EXIF Metadata provided by EXIF.tools
FCC ID Filing: T3W-MUMS-002

Navigation menu