Installation, Operation and Diagnostics for your Communication Interface Unit MIU(Dial or Lease Line modem with) / 485 (RS485) ~ See MIUXXX for modem Technical Data Edition: June 17, 2003 P/N: 0049-0002-010 rev A TABLE of CONTENTS 1.PRODUCT OVERVIEW......................................................................... Page 1 2.PRODUCT DESCRIPTION.................................................................... Page 1 3 SERIAL CONNECTOR SPECIFICATIONS ............................................. Page 2 4.POWER SUPPLY SPECIFICATIONS ..................................................... Page 4 5.RS485 SPECIFICATIONS ..................................................................... Page 5 6.ENVIRONMENTAL SPECIFICATIONS.................................................. Page 6 7.APPROVALS ........................................................................................ Page 6 DRAWING - STANDALONE MODEMS .................................................. Sheet 1 MIU/485 CONFIGURATIONS .......................................... Sheet 2 APPENDIX A: CONNECTOR PIN DEFINITIONS...................................... Page A-1 APPENDIX B:SETUP CONFIGURATION.................................................. Page B-1 APPENDIX C:DIAGNOSTICS .................................................................. Page C-1 Installation, Operation & Diagnostics RS485 (0049-0002-010A) Edition: June 17, 2003Install Op and Diags for MIU Modems and 1. PRODUCT OVERVIEW The CIU (MIU\XXX485) is an industrial modem with an RS-232 to RS485 converter module for direct connection to industrial RS485 Interface units. Though similar to commercial modems, the MIUXXX\485 contains special features that make it particularly well suited for industrial applications. (MIUXXX is for any dial or lease line modems such as MIU14.4L) These capabilities include: Environment The CIU has been designed explicitly for use in industrial environments. In addition to an extended temperature range (-40 to +85o C), the MIUXXX\485 includes surge, shock, vibration, and safety parameters superior to those of conventional commercial modems. Industrial The CIU uses standard industrial connectors for RS485 data and RS232 interfaces. These connectors allow reliable interconnect to other industrial components. Furthermore, the CIU data lines are provided at RS-232 and RS485 signal levels for both stand-alone and embedded applications. 2. PRODUCT DESCRIPTION The CIU provides Dial telephone communication capabilities for the industrial environment. It can be operated stand-alone or as a component of a larger industrial system. 2.1 Telephone Interface The CIU telephone interface operates over two wire lines available in North America. The telephone line interface is environmentally benign, allowing use in Class I, Division 2 applications. 2.2 Data Interface The CIU data interface provides RS-232 compatible serial signaling. The data interface interconnects to industrial controllers at RS-232E, RS422 or RS485 data interface are available as options. 2.3 Power The MIU accepts either regulated 48.0 to 220 volts DC, or regulated 48.0 to 220 volt AC power inputs. Unregulated 12.0 to 24.0 volt DC power input is available as an option. 2.4 Mechanical The CIU consists of two printed circuit boards: A single two sided baseboard and a RS485 module is a single two sided package 5-3/8 x 4 x 1-3/8 suitable for desktop or wall mounting. 2.5 Surge The MIUXXX\485 has double the surge protection of IEC801-4 voltage requirements. (5KVac) Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 1 of 16 3. MIU'S LED, SWITCH & SERIAL CONNECTOR SPECIFICATIONS The CIU/485 communicates with industrial controllers through RS-485 compatible serial signaling. The RS-485 signal levels are used to interconnect with RS-485 compatible embedded controllers. The RS-232E signal levels are used to configure the CIU. The RS232E signal levels are also used to interconnect with RS-232E compatible embedded controllers if required. The RS-232E is present on DB9(MIU), RS485 signal levels are available via four pins' connectors. 4.1 The following lists the CIU/485 serial interfaces. All connector definitions are described in Appendix A RS-232 Configuration Connector (P2) Connector Type: Signal Levels: DB9, (MIU) female, straight board mounts. RS-232 RS485 Configuration Connector (P1) Connector Type: Signal Levels: 4 pin terminal header with .138 spacing RS485 3.2 MIU/485 LED LED Blinks every 4 seconds with AC / DC power 3.3 MIU/485 LED & Switch 1 (internal) S1-1 Closed (ON) LED Blinks with option CD (&C1 AT command) active S1-2 Closed (ON) LED Blinks AC. DC Power ON Note select either 1 or 2 S1-3 Closed, option modem DTR select DB9 DTR S1-4 Closed, option modem DTR select modem's CD 3.4 MIU/485 Switch S3 (external) S3-2 Closed (ON) only for MIU/485 (J1) modem configuration or for RS232 embedded controllers. S3-1,-3 &-4 Open (OFF) S3-1 Closed (ON) only for MIU/485 (P1) RS485 connector (RS485 embedded controllers) S3-2,-3 &m-4 Open (OFF) 3.5 MIU/485 A switch (external) SA-1 Closed (ON) RS485 received data disable TX (Driver Output Enable) SA-2 Closed (ON) RS485 transmit data enable TX (Driver Output Enable) + 5ms SA-3 Closed (ON) RS485 RTS enable TX (Driver Output Enable) should be Open (OFF) SA-4 Closed (ON) RS485 received data is disables with TXD Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 2 of 16 3.5 MIU/485 B switch (external) SB-1 Closed (ON) RS485 Received RX & /RX DC terminated with SB-2 Closed SB-1 Open (OFF) RS485 Received RX & /RX AC terminated with SB-2 Closed SB- 2 Closed (ON) RS485 Received RX & /RX terminated SB- 2 Open (OFF) RS485 Received RX & /RX high impedance (Z) SB-3 & 4 Closed (ON) 2- wire configuration or loopback mode SB-3 & 4 Open (OFF) 4- wire configuration Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 3 of 16 4. POWER SUPPLY SPECIFICATIONS The MIUXXX/485 contains a low quiescent power regulator. TheMIUXXX/485 also has a "low power" standby mode which minimizes overall power requirements when the MIUXXX/485 is used intermittently. 4.1 Power Supply Selection (MIU) The power supply is selected through the use of a 3-pin screw - type terminal connector. Power Connector P3 (MIU) Connector Type: 3 Pin screw- type terminal Regulated Powe r Supply Range: 48.0 to 220 Volts AC/DC. Standby Supply Currents: 200uA Active Supply Currents: 8mA to 40mA plus modem current In-Rush Current: < 250mA Reverse Protection Method: Full wave Bridge Rectifier Over-Voltage Clamp limits: Zener diode Regulated Power Supply Range: (12 - 24VDC) is available as an option Standby Supply Currents: 200uA Active Supply Currents: 35mA to 295mA plus modem current In-Rush Current: < 350mA Reverse Protection Method: Full Wave Bridge Rectifier Over- Voltage Clamp limits: Zener diode and TransZorb TVS Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 4 of 16 5. RS485 SPECIFICATIONS MIUXXXX/485 are low-power Transceiver for RS485 and RS422 communication Features: Point to Point or Multidrop/Multipolling Full or Half Duplex Drivers are short - circuit current limited & protected against excessive power dissipation (shutdown will places the drivers in a high - impedance state). When Drivers are disabled (by TXD), drivers will switch to high impedance state. Note in two-wire or multi-drop/multi-polling networks TX enable by TXD should be active Receiver input impedance is 12K ohms. Reduced slew- rate drivers that minimize EMI and reduce reflections caused by improperly terminated cables This will allow error - free transmitted data up to 200Kbps RS485/RS422 standard covers line lengths up to 4000 feet. For line lengths greater than 4000 feet a line repeater can be added. MIUXXXX/485 can drive 4000 feet of 26AWG twisted - pair cable at 200k bps into 120 ohms load. the To minimize reflections, the line should be terminated at both ends. In multi - polling/multi - drop environments (up to 32 drops) all drops off main cable should be as short as possible. Only the Master/Host unit and the end of cable unit should be terminated. Typical Speed versus Distance - (4-wire point to point 26 AWG twisted cable) SPEED DISTANCE 1200bps 6.0 miles(9.6 km) 2400 bps 4.5 miles (7.2 km) 4800 bps 4.0 miles (5.5 km) 9600 bps 2.5 miles (4.0 km) 19,200 bps 1.8 miles (2.9 km) 38,400 bps 1.4 miles (2.1 km) 56,400 bps 1.1 miles (1.8 km) 115,000 bps 0.6 miles (0.9 km) NOTE: Speed and distances will depend on actual operating environment. 6. ENVIRONMENTAL SPECIFICATIONS The CIU/485 (MIUXXX\485) meets the following environmental specifications. Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 5 of 16 Operating Temperatures -40 to 85o C Storage Temperature -55 to 100o C Relative Humidity 0 to 95% is non-condensing. Altitude 20,000 ft (operating), 40,000 ft (shipping). Vibration Effect Withstand 10 to 500 Hz at 1 g on any axis per SAMA PMC-31-1 without damage or impairment. ESD susceptibility Field connected circuits meet the requirements of IEC 801-2 for ESD withstand capability up to 10 KV. EMI susceptibility Withstand 27 to 1000 MHz per IEC 801-3 level 1 (1v/m) without damage or impairment. EMI radiation Meets FCC Rules Part J, Subpart 15, Class A for radiated emissions. 7. APPROVALS The CIU/485 meets the following approvals: Telephone: FCC Part 68 Emissions FCC Part 15 Environment UL listed (pending) for use in Class I, Division 2, Groups C and D hazardous locations. Install Op and Diags for MIU Modems and RS485 (0049-0002-010A) Page 6 of 16 MIUXXX\485 Power Connection Power Connector RJ11 Leased Line Port Power In MIU (48 to 220VAC/DC (AC or DC) non-polarized Earth Gnd Power In MIU-LV (9 to 36VDC) Positive Voltage In Power Ground Earth Gnd LED 1 Earth/Digital Ground (Jump pins if req’d) DB9 Data Port LED ONE ♦Blinking = POWER ON Steady = MODEM CONNECTED (CD) CIU Installation, Operation & Diagnostics Edition: June 17, 2003 SHEET TWO RJ11 Telco Port * Power Connector (* Not on MIU232/485 Converter) B A LED 1 * Earth/Digital Ground (Jump pins if req’d) * RS485 Connection TX+ TX- RX+ RX- RS232 Data Port (DB9 female) for modem configuration only. 3 & 4 always UP. 1 UP, 2 DOWN when using DB9 for modem configuration. 1 DOWN, 2 UP ~ Modem connected to RS485. Do not connect data to DB9 LED 1... ♦ Blinking = POWER ON ♦ Steady = MODEM CONNECTED (CD) B 4 3 2 1 B 4 3 2 1 Point-to-Point, 4-Wire: Set Switches B-3 & B-4 DOWN(OFF) Point-to-Point, 2-Wire: Set Switches B-3 & B-4 UP(ON) Line Terminate DC : Set Switches B-1 & B-2 UP(ON) Line Terminate AC : set Switches B-2 UP(ON) A For LoopBack Test mode : Set Switches B-3 & B-4 UP(ON) Set Switch A-4 DOWN(OFF) A Multi-drop (Host), 4-Wire: Set Switches B-3 & B-4 DOWN Multi-drop (Host), 2-Wire: Set Switches B-3 & B-4 UP 4 3 2 1 4 3 2 1 Multi-drop (Slave), 4-Wire: Set Switches B-3 & B-4 DOWN Multi-drop (Slave), 2-Wire: Set Switches B-3 & B-4 UP B 4 3 2 1 A 4 3 2 1 Line Terminate Switch A-1: Switch A-2: Switch A-3: Switch A-4: : Set Switches B-2 & B-1DOWN (OFF) for all Slaves except UP(ON) on unit furthest from the Host RTS/CTS Delay: UP = 0 sec; DOWN = 7ms DOWN = TXD enables TX +5ms Select only A-2 or DOWN = RTS enables TX A-3 UP(ON) = TX clamps RXD off (ON) in 2-Wire (half duplex) mode MIUXXX/485 DIP SWITCH SETUP CIU Installation, Operation & Diagnostics Edition: June 17, 2003 SHEET TWO APPENDIX A. CONNECTOR PIN DEFINITIONS CONNECTOR DCD RD TD DTR GND DSR RTS CTS RI PGND P2: RS-232 Configuration Connector (DB9) MIU 1 2 3 4 5 7 8 9 shield data carrier detect receive data transmit data data terminal ready ground 6 data set ready request to send clear to send ring indication protective ground from to to MIUXXX\485 from MIUXXX\485 MIUXXX\485 MIUXXX\485 from to from from MIUXXX\485 MIUXXX\485 MIUXXX\485 MIUXXX\485 _______________________________________________________________________________ CONNECTOR spacing P1: RS-485 Configuration Connector 4 Positions header with .138 Interface to 4 positions Plug -in Terminal Block TXY TXZ RX /RX 1 3 4 transmit data (+) 2 transmit data (-) receive data (+) receive data (-) from MIUXXX\485 module from MIUXXX\485 module to MIUXXX\485 module to MIUXXX/485 module MIUXXX/485 Installation, Operation & Diagnostics Edition: June 17, 2003 Page A-1 APPENDIX B. SETUP CONFIGURATION In order to configure the MIUXXX/485 to remote RTU, Meter or Scada terminals the following setup is required for 2w or 4w (RS485) networks See Fig ONE for MIUXXXX/485 layout and dip switch setting Jumper 7 Pin 1 3&4 Switch Three Switch Three Setting SW - One On SW - Two Off SW - Three Off SW - Four Off RS485 Module Power Plug RJ11 Telco DB9 (RS232) Configuration only Switch One Switch One Setting SW - One Off SW - Two On SW - Three Off SW - Four Off J2 Pin1 Jumper 3&4 5&6 7&8 13 & 15 J8 Pin 1 2&3 DB 9 Connection 1 Carrier Detect 2 Received Data 3 Transmit Data 4 DTR 5 Signal Ground 6 DSR 7 RTS 8 CTS 9 Ring Indicator Final Factory Configuration (MIUXXXX/485) for PEXXX modem module No, Power saving modes, No Auto Reset mode Switch two ON Switch one, three and four are OFF. MIU S3 (external) SW-2 Closed (ON) MIU is configured for DB9 interface to Modem interface connection. SW-1, -3 & -4 Open (OFF) CIU Installation, Operation & Diagnostics Edition: June 17, 2003 Page C-1 1:AT Command (MIU2400/485) (Dial) configuration is: ATE0Q1&C1&D0S0=1&W0 E0 Echo Command disables (no "AT" response to terminal) Q1 Result Codes disable (no result codes return to terminal ring) S0=1 Auto Answer active (first ring modem will go OFF- Hook and start answer sequence) &C1 Carrier Detect is always True (MIU LED will be ON all the time when Carrier Detect is ON. &D0 DTR is ignored 2: AT Command (MIU2496/485, MIU14.4/485 & MIU28.8/485) ATE0Q1&C1&D0&Q6S0=1&W0 E0 Echo Command disables (no "AT" response to terminal) Q1 Result Codes disable (no result codes return to terminal ring, Connect XXX) &Q6 Normal mode (speed buffering) S0=1 Auto Answer active (first ring modem will go OFF- Hook and start answer sequence) &C1 Carrier Detect is always True (MIU LED will be ON all the time when Carrier Detect is ON. &D0 DTR is ignored &K0 No flow control 3: AT Command (MIU14.4L/485) Lease Line ATE0Q1&C1&D0&K0&Q6\M0\H1&Z3=XX&W0 Recycle power (OFF ON) Wait 5 seconds for DSR to switch ON Enter AT\S1AT&W0 Within 45 seconds E0 Echo Command disables (no "AT" response to terminal) Q1 Result Codes disable (no result codes return to terminal ring, Connect XXX) &Q6 Normal mode (speed buffering) \M0 Answer mode (for Remote (Slave unit) local (Master) set for originate \M1 \H1 Lease Line mode \S1 Security mode (if remote RTU is a dumb unit - TxD is always ON CIU Installation, Operation & Diagnostics Edition: June 17, 2003 Page C-1 &Z3=XX Password to exit security mode &C1 Carrier Detect is always True (MIU LED will be ON all the time when Carrier Detect is ON. &D0 DTR is ignored &K0 No flow control 4: AT Command (MIU9.6L/485) Lease Line ATE0Q1&C1&D0&K0&Q6\M0\H1W0 E0 Echo Command disables (no "AT" response to terminal) Q1 Result Codes disable (no result codes return to terminal ring, Connect (XXX) &Q6 Normal mode (speed buffering) \M0 Answer mode (for Remote (Slave)unit) local (Master) set for originate \M1 \H1 Lease Line mode \S1 Security mode (Not available for MIU9.6L) &C1 Carrier Detect is always true (MIU LED will be ON all the time when Carrier Detect is ON. &D0 DTR is ignored &K0 No flow control Note &Q5 error detection and data compression can be used If the host software will support EC Switch Setting (MIUXXX/485) (Typical) MIU S3 (external) SW-1 Closed (ON) MIU is configured for RS485 Module (RS485 RxD (Output) to Modem TxD (input)) SW-2, -3 & -4 Open (OFF) 2- Wire Configuration on PE485 module SB-1 Closed (ON) DC Termination Open (OFF) AC Termination SB-2 Closed (ON) Line Termination SB-3 & -4 Closed (ON) 2- Wire SA- 1 SA- 2 SA- 3 SA- 4 Open (OFF) Closed (ON) TxD (transmit data) enables TX (Driver Output Enable) + 5ms Open (OFF) Closed (ON) Received data is disable with TX enable (TxD) 4- Wire Configuration for PE485 module CIU Installation, Operation & Diagnostics Edition: June 17, 2003 Page C-1 SB-1 Closed(ON) DC Terminated SB-2 Closed (ON) Line Termination SB-3 & -4 Open (OFF) 4- wire SA-1 Open (OFF) RTS follows CTS no delay SA-2 Open (OFF) SA-3 Closed (ON) RTS (always ON by MIU internal J7 (1/2) setting) enables TxEN) SA-4 Open (OFF) TxD will not disable RxD MIU S3 (external) SW-1 Closed (ON) MIU is configured for RS485 Module (RS485 RxD (Output) to Modem TxD (input)) SW-2, -3 & -4 Open (OFF) SA2 & SA3 can be configures for TxD enable TxEn signal if there are several master locations in the network. SA2 is Closed (ON) TxD (transmit data) enables TX (Driver Output + 5ms SA3 is Open (OFF) TxD will not disable RxD Enable) MIUXXXX/485 Final Connection Ensure that MIUXXXX/485 J7 (internal jumper) 1/2 is connected APPENDIX C. CONNECTOR DIAGOSTICS RS485 CONNECTION FAILURE CIU Installation, Operation & Diagnostics Edition: June 17, 2003 Page C-1 To test RS485 module set switch SB-3 & -4 Closed (ON) to loopback data to the host modem. This test is for RS485 2- wire and 4- wire configurations. Connect MIUXXXX/485 TXY (+) and TXZ (-) to the embedded controller RS485 DIAGNOSTICS RS485 CONNECTION FAILURE To test RS485 module set switch SB-3 & -4 Closed (ON) to loopback data to the host modem. This test is for RS485 2- wire and 4- wire configurations. Connect MIUXXXX/485 TXY (+) and TXZ (-) to the embedded controller RS485 connection MIUXXXX/485 + ------------------- + RS485 embedded controller - ------------------- In some applications RS485 TXY (+) and TXZ (-) may have to be connected to RS485 embedded controller in the following setup MIUXXX/485 + ----------------- - RS485 embedded controller - ----------------- + CIU Installation, Operation & Diagnostics Edition: June 17, 2003 Page C-1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2003:06:17 09:03:40Z Modify Date : 2003:06:24 00:49:19-07:00 Page Count : 16 Creation Date : 2003:06:17 09:03:40Z Author : Marc Fishel, High-Tech Publications, www.htpubs.com Producer : Acrobat PDFWriter 4.0 for Windows Mod Date : 2003:06:24 00:49:19-07:00 Metadata Date : 2003:06:24 00:49:19-07:00 Creator : Marc Fishel, High-Tech Publications, www.htpubs.com Title : MIU Dial or Leased Line modem with RS-485 (0049-0002-010A)EXIF Metadata provided by EXIF.tools