Telensa 2NXD Telecell with location and dimming control User Manual User Installation Manual

Telensa Ltd. Telecell with location and dimming control User Installation Manual

User Installation Manual

COMMERCIAL IN CONFIDENCE                     6LT041 05      29 Oct 2014  Page 1 of 9  QP4016 06 - Tech Note Template Technical Note Subject: User Manual and instructions for the EU & US Telecell Date: 29 Oct 2014 Document ref:   6LT041  05        Intentionally Blank
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template  Telensa    Telecell 2 User Manual
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template Contents CONTENTS ................................................................................................................................................................ 3 1 OPERATIONAL SAFETY NOTICES ............................................................................................................ 4 2 TELECELL VARIANTS .................................................................................................................................. 4 3 SPECIFICATIONS ........................................................................................................................................... 4 3.1 EU TYPE PRODUCTS, T2E… ....................................................................................................................... 4 3.2 US TYPE PRODUCTS, T2A… ....................................................................................................................... 4 3.3 NOTES ON DIMMING CONTROL OUTPUTS ...................................................................................................... 5 4 INSTALLATION INSTRUCTIONS ............................................................................................................... 5 4.1 DIMMING CONTROL TELECELL .................................................................................................................... 5 4.2 STANDARD (NON DIMMING) TELECELL ........................................................................................................ 5 5 TELECELL CONNECTION DIAGRAMS .................................................................................................... 6 6 NOTICES FOR PRODUCTS OPERATED IN THE USA & CANADA ...................................................... 9
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template 1  Operational Safety Notices Installer Installers must be suitably trained and qualified for electrical work, according to the laws and local codes for the locality and country where the unit will be installed. This unit must only be installed by personnel that have been trained by Telensa or their representatives to carry out this work. Power Supply In the case of field installation the supply voltage present on the luminaire NEMA socket is hazardous and all necessary precautions must be taken to ensure the safety of the installer. Isolate the supply to the NEMA socket before removing an old photocontrol, or installing the telecell.   2  Telecell Variants There are two variants of the Telecell 2 model; dimming control and standard / non-dimming control. Dimming control products are identified by the text “0-10V & DALI” on the product label. Telecell products are built and supplied to either the EU or US standards: EU product part numbers start with: T2E... US part numbers start with T2A… The products are supplied with NEMA pin connections for insertion into the photocell socket on top of a luminaire.  3  Specifications 3.1  EU Type Products, T2E… Electrical Parameters:   Supply voltage:     100 - 253 VAC, 50-60Hz   Maximum switching current:  10A                Radio:       Transmit Power:     25mW EIRP, <1% transmit duty cycle.         Operating band:     868MHz license free ISM band Operating Temperature:    NEMA variants:    -40 to 70 °C Ambient  3.2  US Type Products, T2A… Electrical Parameters:   Supply voltage:     100 - 277 VAC, 50-60Hz   Maximum switching current:  10A                Radio:       Transmit Power:     100mW EIRP Operating band:     915MHz license free ISM band Operating Temperature:    NEMA variants:    -40 to 70 °C Ambient
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template 3.3  Notes on dimming control outputs These notes apply to products with the integrated dimming control function:  Suitable for use with dimmable ballasts with an isolated or non-isolated control input  DALI or 0-10V control mode is configured over the air by the Telensa Central System  0-10V control requires the normally fitted internal pull-up resistor in the ballast  DALI control includes the DALI supply function within the telecell and is suitable for controlling from one to three dimmable ballasts. 4  Installation Instructions Instructions for the installation of each of the different variants of Telecell are given below. Figure 2 shows  a  wiring  diagram  for  a  standard  lamp  with a  non-dimmable  ballast.  Figure  3  shows  dimming control using a dimmable ballast. 4.1  Dimming Control Telecell This product will ONLY control a lamp that incorporates a 5 or 7 pin NEMA socket compliant with ANSI C136.41 2013. Insert unit into NEMA socket on street light ensuring the largest tab on the unit places into the largest tab recess on the NEMA socket on the street light. Turn by hand clockwise typically 30 degrees to lock in place. 4.2  Standard (non dimming) Telecell Insert unit into NEMA socket on street light ensuring the largest tab on the unit places into the largest tab recess on the NEMA socket on the street light. Turn by hand clockwise typically 30 degrees to lock in place.
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template  Fig 1: Example NEMA socket showing alignment        5  Telecell Connection Diagrams Refer to figures 2 and 3 overleaf.  Colour code Function Notes Brown LIVE/LINE in  Blue NEUTRAL in  Red LIVE switched out Relay switched inside telecell Violet + Dimmer control Integrated dimming function telecells only. DALI control is not polarity sensitive. Grey - Dimmer control
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template   Figure 2: Wiring Diagram for Telecell - No Dimming Function
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template TelecellDimmableBallastLampLive inNeutral Live outDimmer controlLampLampNeutralLive inCtrl 1Ctrl 2 Figure 3: Wiring Diagram for Integral Dimming Control Telecell
  6LT041 05       29 Oct 2014    QP4016 07- Tech Note Template 6  Notices for products operated in the USA & Canada  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to Part 15 of FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  Reorient or relocate the receiving antenna  Increase the separation between the equipment and receiver  Consult a dealer or an experienced radio/TV technician for help. Note that no changes shall be made to the equipment without the manufacturer’s permission as this may void the user’s authority to operate the equipment. This transmitter must not be co-located or operated with any other antenna or transmitter This device complies with Part 2.1091 of the FCC Rules for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device complies with RSS-310 of Industry Canada. Operation is subject to the condition that this device does not cause harmful interference.

Navigation menu