AUDIOCOM
"
INTERCOM SYSTEMS
MODEL
PS-1
FLUSH-MOUNT
POWER SUPPLY
INSTALLATION AND OPERATION INSTRUCTIONS
GENERAL DESCRIPTION
WARNING
The Telex AudiocomT" Model PS-1 F Power Supply THE PS-IF REQUIRES CONNECTION OF LINE
mounts in a standard two-gang electrical outlet box. VOLTAGE AND LOW VOLTAGE WIRING IN THE
It may be used to power a single intercom channel SAME OUTLET BOX. ANY INSTALLATION OF
containing up to 25 belt-pack headset stations. It THIS UNIT MUST MEET ALL RELEVANT
may also be used as a local power source for NATIONAL AND LOCAL ELECTRICAL CODES.
speaker stations such as the Telex Model ICQSF.
INSTALLATION
1. Ac power should be supplied from a circuit
SPECIFICATIONS
Power Requirements: 105-1 25 Vac, 50-60 Hz,
30 watts
protected by a service fuse or circuit breaker
with a maximum rating of 15 amps. Connect ac
power to the black and white leadwires; connect
ground to the green wire.
2. To power an intercom channel: Connect the
Output Voltage: 24 Vdc regulated (less than intercom channel to the CHANNEL terminals,
50 millivolts ripple) and connect intercom dc return to the SHLD
terminal.
Output Current:
-
500 milliamps maximum continuous
-
700 milliamps maximum intermittent
-
240 milliamps short circuit current limiting
Channel Terminating Impedance (provided
by
PS-1
F):
300 ohms t15O/0
To locally power a speaker station: Connect the
speaker station positive terminal to either one of
the PS-1 F CHANNEL terminals, and connect
speaker station ground to the PS-1
F
SHLD
terminal. The remaining CHANNEL terminal on
the PS-IF is not used. On the speaker station,
be sure to remove the jumper installed between
-.
Connectors: the +24 and PH terminals. (This jumper is used
only when the speaker station is phantom
-
Intercom Channel: Three screw terminals with powered from the intercom channel.)
wire clamps for No. 14-22 AWG stranded or solid
wire
3.
Mount the PS-IF in an electrical box using the
-
Power: Three wire pigtails screws provided with the unit.
1
J
I
Model
PS-IF
Dimensional Drawing
TELEX.
TELEX
COMMUNICATIONS, INC. 9600 Aldrich Ave. So., Minneapolis, MN
55420
U.S.A.
CR3
.ISUF
,
CHANNEL
CHASSIS CONNECTION
Model PS-1F Schematic Diagram
SERVICE INFORMATION
FACTORY SERVICE
All Audiocom equipment returns must be sent
prepaid. Telex will not accept collect shipments.
The following information must accompany all
equipment returned for repair:
IN-WARRANTY RETURNS:
All equipment repaired in-warranty by Telex will
be returned prepaid by Telex.
If requested, an estimate will be sent before
repairing non-warranty equipment. This is a
guaranteed estimate -final charges will not
exceed what is quoted. If payment is sent along
with your estimate approval, COD charges will be
avoided; otherwise, equipment will be returned to
you COD.
1 Your name, address and telephone number.
FACTORY SERVICE ADDRESS:
2. Purchaser's name and address (if different
from above).
3. Copy of proof of puchase (keep your original)
4. Model and serial numbers (or date codes)
Service Department
Telex Communications, Inc.
1720 East 14th Street
Glencoe, Minnesota 55336 U.S.A.
5. A complete description of the problem.
CUSTOMER ASSISTANCE
NON-WARRANTY RETURNS:
Customer Service Department
Your name, address and telephonernumber. Telex Communications, Inc.
9600 Aldrich Avenue South
2. Model and serial numbers (or date codes) Minneapolis, Minnesota 55420 U.S.A.
Telephone: (61 2) 884-4051
3. A complete description of the problem. (Collect calls not accepted)