Telit Communications S p A GE865C Quadband GSM/ GPRS Module User Manual GE865 Harware User Guide
Telit Communications S.p.A. Quadband GSM/ GPRS Module GE865 Harware User Guide
User Manual
GE865 Hardware User Guide 1vv0300799 Rev.11 13-07-2010 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 APPLICABILITY TABLE PRODUCT GE865 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 2 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 DISCLAIMER The information contained in this document is the proprietary information of Telit Communications S.p.A. and any disclosure to persons other than the officers, employees, agents or subcontractors of the owner or licensee of this document, without the prior written consent of Telit, is strictly prohibited. Telit makes every effort to ensure the quality of the information it makes available. Notwithstanding the foregoing, Telit does not make any warranty as to the information contained herein, and does not accept any liability for any injury, loss or damage of any kind incurred by use of or reliance upon the information. Telit disclaims any and all responsibility for the application of the devices characterized in this document, and notes that the application of the device must comply with the safety standards of the applicable country, and where applicable, with the relevant wiring rules. Telit reserves the right to make modifications, additions and deletions to this document due to typographical errors, inaccurate information, or improvements to programs and/or equipment at any time and without notice. Such changes will, nevertheless be incorporated into new editions of this application note. All rights reserved. © 2009, 2010 Telit Communications S.p.A. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 3 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Contents APPLICABILITY TABLE ....................................................................................................................................................... 2 INTRODUCTION ...................................................................................................................................................... 6 1.1 SCOPE .............................................................................................................................................................................. 6 1.2 AUDIENCE ......................................................................................................................................................................... 6 1.3 CONTACT INFORMATION, SUPPORT .................................................................................................................................... 6 1.4 DOCUMENT ORGANIZATION ................................................................................................................................................ 7 1.5 TEXT CONVENTIONS........................................................................................................................................................... 8 1.6 RELATED DOCUMENTS ...................................................................................................................................................... 8 1.7 DOCUMENT HISTORY ......................................................................................................................................................... 9 OVERVIEW ............................................................................................................................................................. 10 GE865 MECHANICAL DIMENSIONS .................................................................................................................. 12 GE865 MODULE CONNECTIONS ........................................................................................................................ 13 4.1 PIN-OUT ....................................................................................................................................................................... 13 4.1.1 BGA Balls Layout................................................................................................................................................. 16 HARDWARE COMMANDS .................................................................................................................................... 17 5.1 TURNING ON THE GE865 ................................................................................................................................................ 17 5.2 TURNING OFF THE GE865 .............................................................................................................................................. 22 5.3 RESETTING THE GE865 ................................................................................................................................................... 25 5.3.1 Hardware Unconditional restart ....................................................................................................................... 25 POWER SUPPLY ................................................................................................................................................... 28 6.1 POWER SUPPLY REQUIREMENTS ...................................................................................................................................... 28 6.2 POWER CONSUMPTION .................................................................................................................................................... 29 6.3 GENERAL DESIGN RULES ................................................................................................................................................ 30 6.3.1 Electrical Design Guidelines.............................................................................................................................. 30 6.3.2 Thermal Design Guidelines ............................................................................................................................... 34 6.3.3 Power Supply PCB layout Guidelines ............................................................................................................... 36 ANTENNA .............................................................................................................................................................. 37 7.1 GSM ANTENNA REQUIREMENTS ...................................................................................................................................... 37 7.2 GSM ANTENNA - PCB LINE GUIDELINES ......................................................................................................................... 38 7.3 GSM ANTENNA - INSTALLATION GUIDELINES................................................................................................................... 39 LOGIC LEVEL SPECIFICATIONS ......................................................................................................................... 40 8.1 RESET SIGNAL ................................................................................................................................................................. 41 SERIAL PORTS ..................................................................................................................................................... 42 9.1 MODEM SERIAL PORT ................................................................................................................................................ 42 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 4 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 9.2 RS232 LEVEL TRANSLATION ............................................................................................................................................ 44 9.3 5V UART LEVEL TRANSLATION ........................................................................................................................................ 48 10 AUDIO SECTION OVERVIEW ........................................................................................................................... 50 10.1 ELECTRICAL CHARACTERISTICS ..................................................................................................................................... 51 10.1.1 Input Lines ......................................................................................................................................................... 51 10.1.2 Output Lines....................................................................................................................................................... 52 11 GENERAL PURPOSE I/O ................................................................................................................................. 53 11.1 GPIO LOGIC LEVELS ...................................................................................................................................................... 54 11.2 USING A GPIO PAD AS INPUT ...................................................................................................................................... 56 11.3 USING A GPIO PAD AS OUTPUT ................................................................................................................................... 56 11.4 USING THE RF TRANSMISSION CONTROL GPIO4 ............................................................................................................ 56 11.5 USING THE RFTXMON OUTPUT GPIO5 ........................................................................................................................ 57 11.6 USING THE ALARM OUTPUT GPIO6 ................................................................................................................................ 57 11.7 USING THE BUZZER OUTPUT GPIO7 .............................................................................................................................. 58 11.8 MAGNETIC BUZZER CONCEPTS ...................................................................................................................................... 59 11.8.1 Short Description .............................................................................................................................................. 59 11.8.2 Frequency Behaviour........................................................................................................................................ 59 11.8.3 Power Supply Influence ................................................................................................................................... 60 11.8.4 Working Current Influence .............................................................................................................................. 60 11.9 INDICATION OF NETWORK SERVICE AVAILABILITY ............................................................................................................. 61 11.10 RTC BYPASS OUT ........................................................................................................................................................ 63 11.11 EXTERNAL SIM HOLDER IMPLEMENTATION .................................................................................................................. 63 12 DAC AND ADC SECTION ................................................................................................................................. 64 12.1 DAC CONVERTER .......................................................................................................................................................... 64 12.1.1 Description ......................................................................................................................................................... 64 12.1.2 Enabling DAC ..................................................................................................................................................... 65 12.1.3 Low Pass Filter Example ................................................................................................................................. 65 12.2 ADC CONVERTER .......................................................................................................................................................... 66 12.2.1 Description ......................................................................................................................................................... 66 12.2.2 Using ADC Converter ........................................................................................................................................ 66 13 MOUNTING THE GE865 ON YOUR BOARD .................................................................................................... 67 13.1 GENERAL ...................................................................................................................................................................... 67 13.2 MODULE FINISHING & DIMENSIONS ................................................................................................................................ 67 13.3 RECOMMENDED FOOT PRINT FOR THE APPLICATION ........................................................................................................ 68 13.4 DEBUG OF THE GE865 IN PRODUCTION .......................................................................................................................... 69 13.5 STENCIL........................................................................................................................................................................ 69 13.6 PCB PAD DESIGN .......................................................................................................................................................... 70 13.7 SOLDER PASTE .............................................................................................................................................................. 72 13.7.1 GE865 Solder reflow ......................................................................................................................................... 73 14 PACKING SYSTEM ........................................................................................................................................... 76 14.1 MOISTURE SENSIBILITY .................................................................................................................................................. 77 15 CONFORMITY ASSESSMENT ISSUES............................................................................................................ 78 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 5 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 16 SAFETY RECOMMANDATIONS ....................................................................................................................... 80 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 6 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Introduction 1.1 Scope The aim of this document is the description of some hardware solutions useful for developing a product with the Telit GE865 module. 1.2 Audience This document is intended for Telit customers, who are integrators, about to implement their applications using our GE865 modules. 1.3 Contact Information, Support For general contact, technical support, to report documentation errors and to order TS-EMEA@telit.com TS-NORTHAMERICA@telit.com TS-LATINAMERICA@telit.com TS-APAC@telit.com Alternatively, use: http://www.telit.com/en/products/technical-support-center/contact.php For detailed information about where you can buy the Telit modules or for recommendations on accessories and components visit: http://www.telit.com To register for product news and announcements or for product questions contact Our aim is to make this guide as helpful as possible. Keep us informed of your comments and suggestions for improvements. Telit appreciates feedback from the users of our information. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 7 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 1.4 Document Organization This document contains the following chapters: provides a scope for this document, target audience, contact and support information, and text conventions. provides an overview of the document. Chapter 4 Module Connections out configuration and layout. How to operate on the module via hardware. Power supply requirements and general design rules. The antenna connection and board layout design are the most important parts in the full product design. Specific values adopted in the implementation of logic levels for this module. The serial port on the Telit GE865 is the core of the interface between the module and OEM hardware Refers to the audio blocks of the Base Band Chip of the GE865 Telit Modules. How the general purpose I/O pads can be configured. Deals with these two kind of converters. E865 Recommendations and Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 8 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 1.5 Text Conventions Danger This information MUST be followed or catastrophic equipment failure or bodily injury may occur. Caution or Warning Alerts the user to important points about integrating the module, if these points are not followed, the module and end user equipment may fail or malfunction. Tip or Information Provides advice and suggestions that may be useful when integrating the module. All dates are in ISO 8601 format, i.e. YYYY-MM-DD. 1.6 Related Documents Telit's GSM/GPRS Family Software User Guide, 1vv0300784 Audio settings application note , 80000NT10007a Digital Voice Interface Application Note, 80000NT10004a GE865 Product description, SIM Holder Design Guides, 80000NT10001a AT Commands Reference Guide, 80000ST10025a Telit EVK2 User Guide, 1vv0300704 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 9 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 1.7 Document History R e v i si o n Date ISSUE#0 ISSUE#1 ISSUE#2 ISSUE#3 2009-01-26 2009-02-15 2009-02-15 2009-03-18 ISSUE#4 ISSUE#5 ISSUE#6 ISSUE#7 2009-04-02 03/06/2009 04/06/2009 2009-05-26 ISSUE#8 2009-06-18 ISSUE#9 2009-07-27 ISSUE#10 2009-09-22 ISSUE#11 2010-07-12 Changes First ISSUE# 0 - DRAFT Updated current consumptions table Updated Pinout description Updated mechanical dimensions (balls spacing), charger description removed, Added better explanation of pin H5 (RF) and H1 (service) Updated VBATT supply Range, DAC schematic, Conformity assessment Updated section 13 (FCC Conformity assessment) Updated section 13 (FCC Conformity assessment) Applied new layout + minor editing Edited PCB pad design par.13.1.6 Updated all schematic drawings Updated Chapter 10 Audio Section Substituted GE865-QUAD with GE865 Corrected GE864-QUAD/PY with GE865 Updated Overview section Changed par. 5.1 Turning ON and par. 6.1 Power supply Requirements Changed par. 13.3 and par.15 Conformity Assessment Issues Added DVI pins description Updated table of power consumptions. Added note on chapters 5.1, 5.2, 9.3 Corrected chapter 1.1 Updated logic levels specification Added NOTE on ON_OFF procedure, serial port , GPIO section Corrected note on RESET section Updated Current Consumptions Updated flow charts for ON OFF and Reset Updated name for Auxiliary UART port Updated Chapter 7 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 10 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 2 Overview The aim of this document is the description of some hardware solutions useful for developing a product with the Telit GE865 module. In this document all the basic functions of a mobile phone will be taken into account; for each one of them a proper hardware solution will be suggested and eventually the wrong solutions and common errors to be avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided shall be considered as mandatory, while the suggested hardware configurations shall not be considered mandatory, instead the information given shall be used as a guide and a starting point for properly developing your product with the Telit GE865 module. For further hardware details that may not be explained in this document refer to the Telit GE865 Product Description document where all the hardware information is reported. NOTICE: (EN) The integration of the GSM/GPRS GE865 cellular module within user application shall be done according to the design rules described in this manual. GE865 (DE) Die Integration des GE865 GSM/GPRS Mobilfunk-Moduls in ein Gerät muß gemäß der in diesem Dokument beschriebenen Kunstruktionsregeln erfolgen. (SL) Integracija GSM/GPRS GE865 modula v u projektna navodila, opisana v tem piročniku. (SP) La utilización del modulo GSM/GPRS GE865 debe ser conforme a los usos para los cuales ha sido deseñado descritos en este manual del usuario. u module cellulaire GSM/GPRS GE865 (HE) GE865-QUAD Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 11 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 The information presented in this document is believed to be accurate and reliable. However, no responsibility is assumed by Telit Communications S.p.A. for its use, nor any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent rights of Telit Communications S.p.A. other than for circuitry embodied in Telit products. This document is subject to change without notice. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 12 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 3 GE865 Mechanical Dimensions The GE865 overall dimensions are: Length: Width: Thickness: 22 mm 22 mm 3.0 mm Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 13 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 4 GE865 module connections 4.1 PIN-OUT Ball Signal I/O Function Note Type E8 EAR- AO Earphone signal output, phase - Audio D8 EAR+ AO Earphone signal output, phase + Audio B8 MIC+ AI Mic.signal input; phase+ Audio C8 MIC- AI Mic.signal input; phase- Audio Audio SIM card interface A5 SIMCLK External SIM signal Clock A8 SIMRST External SIM signal Reset A6 SIMIO I/O B7 SIMIN A7 SIMVCC External SIM signal External SIM signal External SIM signal Data I/O 1,8 / 3V 1,8 / 3V 4.7K Pull up 1,8 / 3V Presence (active low) 1,8 / 3V Power supply for the SIM 1,8 / 3V Trace D1 TX_AUX Auxiliary UART (TX Data to DTE) CMOS 2.8V E1 RX_AUX Auxiliary UART (RX Data from DTE) CMOS 2.8V Prog. / Data + HW Flow Control A3 C103/TXD Serial data input (TXD) from DTE CMOS 2.8V A4 C104/RXD CMOS 2.8V B3 C108/DTR A1 C105/RTS A2 C106/CTS B5 C109/DCD B2 C107/DSR Serial data output to DTE Input for Data terminal ready signal (DTR) from DTE Input for Request to send signal (RTS) from DTE Output for Clear to send signal (CTS) to DTE Output for Data carrier detect signal (DCD) to DTE Output for Data set ready signal (DSR) to DTE B4 C125/RING Output for Ring indicator signal (RI) to DTE CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V DAC and ADC G7 DAC_OUT AO Digital/Analog converter output D/A F5 ADC_IN1 AI Analog/Digital converter input A/D F6 ADC_IN2 AI Analog/Digital converter input A/D Miscellaneous Functions C1 RESET* Reset input H2 VRTC AO VRTC Backup capacitor Power G8 STAT_LED Status indicator led CMOS 1.8V B1 ON_OFF* Input command for switching power ON or OFF (toggle command). 47K Pull Up Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved Pull up to VRTC page 14 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Ball Signal I/O Function Note Type E2 PWRMON Power ON Monitor CMOS 2.8V H5 Antenna RF H1 Service Antenna output 50 Ω Service pin can be used to upgrade the module from ASC1 as a alternative to default upgrading procedure using ASC0 CMOS 2.8V GPIO D3 GPIO_01 / DVI_WA0 I/O D2 GPIO_02 / JDR / DVI_RX I/O E4 GPIO_03 / DVI_TX I/O H7 GPIO_04 / TX_DISAB I/O G2 GPIO_05 / RFTXMON I/O H8 GPIO_06 / ALARM I/O G6 GPIO_07 / BUZZER I/O D4 GPIO_08 / DVI_CLK I/O F4 GPIO_09 I/O E3 GPIO_10 I/O GPIO01 Configurable GPIO / Digital Audio Interface (WA0) GPIO02 I/O pin / Jammer Detect Report / Digital Audio Interface (RX) GPIO03 GPIO I/O pin // Digital Audio Interface (TX) GPIO04 Configurable GPIO / TX Disable input GPIO05 Configurable GPIO / Transmitter ON monitor GPIO06 Configurable GPIO / ALARM CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V CMOS 2.8V GPIO07 Configurable GPIO / Buzzer GPIO08 Configurable GPIO / Digital Audio Interface (CLK) GPIO09 CMOS 2.8V 4.7 K Pull Up Open Drain GPIO10 4.7 K Pull Up Open Drain CMOS 2.8V Power Supply F1 VBATT Main power supply (Baseband) Power F2 VBATT_PA Main power supply (Radio PA) Power F3 VBATT_PA Main power supply (Radio PA) Power G1 GND Ground Power C2 GND Ground Power C7 GND Ground Power E5 GND Ground Power E7 GND Ground Power G5 GND Ground Power G4 GND Ground Power G3 GND Ground Power H3 GND Ground Power H6 GND Ground Power RESERVED B6 C3 C4 C5 C6 D5 D6 D7 E6 F7 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 15 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Ball Signal I/O F8 Function Note Type WARNING: Reserved pins must not be connected. NOTE: If not used, almost all pins should be left disconnected. The only exceptions are the following pins: pin F1,F2,F3 G1, C2, C7, E5, E7, G5, G4, G3, H3, H6 signal VBATT & VBATT_PA B1 A3 C1 A4 A1 D1 E1 H1 ON/OFF* TXD RESET* RXD RTS TXD_AUX RXD_AUX Service GND RTS pin should be connected to the GND (on the module side) if flow control is not used Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 16 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 4.1.1 BGA Balls Layout TOP VIEW C105 / RTS ON_OFF RESET* TX_AUX RX_AUX VBATT GND SERVICE C106/CTS C107/DSR GND GPIO_02 / DVI_RX PWRMON VBATT_PA GPIO_05 VRTC C103_TXD C108/DTR GPIO_01 / DVI_WA0 GPIO_10 VBATT_PA GND GND C104/RXD C125/RING GPIO_08 / DVI_CLK GPIO_03 / DVI_TX GPIO_09 GND SIMCLK C109/DCD GND ADC1 GND ANT SIMIO ADC2 GPIO_07 GND SIMVCC SIMIN GND GND DAC GPIO_04 SIMRST MIC+ MIC- EAR+ EAR- STATLED GPIO_06 LEGENDA: AUDIO SIM CARD ANTENNA UARTS DAC and ADC MISCELLANEOUS GPIO POWER SUPPLY VBATT POWER SUPPLY GND RESERVED NOTE: The pin defined as H4 has to be considered RESERVED and not connected on any pin in the application. The related area on the application has to be kept empty. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 17 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 5 Hardware Commands 5.1 Turning ON the GE865 To turn on the GE865 the pad ON# must be tied low for at least 1 second and then released. When the power supply voltage is lower than 3.4V the pad ON# must be tied low at least 3 seconds. The maximum current that can be drained from the ON# pad is 0,1 mA. A simple circuit to do it is: ON# R1 Q1 Power ON impulse R2 GND NOTE: Don't use any pull up resistor on the ON# line, it is internally pulled up. Using pull up resistor may bring to latch up problems on the GE865 power regulator and improper power on/off of the module. The line ON# must be connected only in open collector configuration. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 18 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 NOTE: In this document all the lines that are inverted, hence have active low signals are labelled TIP: To check if the device has powered on, the hardware line PWRMON should be monitored. After 900ms the line raised up the device could be considered powered on. NOTE: It is mandatory to avoid sending data to the serial ports during the first 200mS of the module startup. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 19 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 A flow chart showing the proper turn on procedure is displayed below: NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the GE865 when the module is powered off or during an ON/OFF transition. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 20 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 A flow chart showing the AT command managing procedure is displayed below: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 21 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 For example: 1- Let's assume you need to drive the ON# pad with a totem pole output of a +3/5 V microcontroller (uP_OUT1): 2- Let's assume you need to drive the ON# pad directly with an ON/OFF button: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 22 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 5.2 Turning OFF the GE865 Turning off of the device can be done in two ways: via AT command (see GE865 Software User Guide, AT#SHDN) by tying low pin ON# Either ways, the device issues a detach request to network informing that the device will not be reachable any more. To turn OFF the GE865 the pad ON# must be tied low for at least 2 seconds and then released. A Pulse duration less than 2 seconds should also start the power off procedure, but this is not guaranteed. The same circuitry and timing for the power on must be used. The device shuts down after the release of the ON# pad. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 23 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 The following flow chart shows the proper turnoff procedure: TIP: To check if the device has been powered off, the hardware line PWRMON must be monitored. The device is powered off when PWRMON goes low. NOTE: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 24 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the GE865 when the module is powered off or during an ON/OFF transition. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 25 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 5.3 Resetting the GE865 5.3.1 Hardware Unconditional restart WARNING: The hardware unconditional Restart must not be used during normal operation of the device since it does not detach the device from the network. It shall be kept as an emergency exit procedure to be done in the rare case that the device gets stacked waiting for some network or SIM responses. To unconditionally reboot the GE865, the pad RESET# must be tied low for at least 200 milliseconds and then released. The maximum current that can be drained from the RESET# pad is 0,15 mA. NOTE: Do not use any pull up resistor on the RESET* line nor any totem pole digital output. Using pull up resistor may bring to latch up problems on the GE865 power regulator and improper functioning of the module. The line RESET* must be connected only in open collector configuration. TIP: The unconditional hardware restart must always be implemented on the boards and the software must use it as an emergency exit procedure. A simple circuit to do it is: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 26 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 In the following flow chart is detailed the proper restart procedure: NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the GE865 when the module is powered off or during an ON/OFF transition. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 27 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 For example: 1- Let us assume you need to drive the RESET# pad with a totem pole output of a +3/5 V microcontroller (uP_OUT2): Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 28 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6 Power Supply The power supply circuitry and board layout are a very important part in the full product design and they strongly reflect on the product overall performances, hence read carefully the requirements and the guidelines that will follow for a proper design. 6.1 Power Supply Requirements The external power supply must be connected to VBATT & VBATT_PA signals and must fulfill the following requirements: POWER SUPPLY Nominal Supply Voltage Normal Operating Voltage Range Extended Operating Voltage Range 3.8 V 3.4 V÷ 4.20 V 3.22 V÷ 4.50 V NOTE: The Operating Voltage Range MUST never be exceeded; care must be taken in order to fulfil min/max voltage requirement. NOTE: Overshoot voltage (regarding MAX Extended Operating Voltage) and drop in voltage (regarding MIN Extended Operating Voltage) MUST never be exceeded; and application of the HW User guide suggestions. NOTE: When the power supply voltage is lower than 3.4V, to turn ON the module, the pad ON# must be tied low for at least 3 seconds. See para 5.1. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 29 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6.2 Power Consumption The GE865 power consumptions are: GE865 Average (mA) SWITCHED OFF Switched Off <62uA Mode AT+CFUN=1 AT+CFUN=4 16,0 16,0 3,9 2,5 AT+CFUN=0 or =5 2,4 1,5 CSD TX and RX mode GSM900 CSD PL5 240 DCS1800 CSD PL0 175 GPRS (class 1) 1TX + 1RX GSM900 PL5 225 DCS1800 PL0 160 GPRS (class 10) 2TX + 3RX GSM900 PL5 420 DCS1800 PL0 290 Mode description Module supplied but Switched Off IDLE mode Normal mode: full functionality of the module Disabled TX and RX; module is not registered on the network Paging Multiframe 2 Paging Multiframe 3 Paging Multiframe 4 Paging Multiframe 9 GSM VOICE CALL GPRS Sending data mode GPRS Sending data mode The GSM system is made in a way that the RF transmission is not continuous, else it is packed into bursts at a base frequency of about 216 Hz, and the relative current peaks can be as high as about 2A. Therefore the power supply has to be designed in order to withstand with these current peaks without big voltage drops; this means that both the electrical design and the board layout must be designed for this current flow. If the layout of the PCB is not well designed a strong noise floor is generated on the ground and the supply; this will reflect on all the audio paths producing an audible annoying noise at 216 Hz; if the voltage drop during the peak current absorption is too much, then the device may even shutdown as a consequence of the supply voltage drop. NOTE: The electrical design for the Power supply should be made ensuring it will be capable of a peak current output of at least 2 A. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 30 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6.3 General Design Rules The principal guidelines for the Power Supply Design embrace three different design steps: the electrical design the thermal design the PCB layout. 6.3.1 Electrical Design Guidelines The electrical design of the power supply depends strongly from the power source where this power is drained. We will distinguish them into three categories: +5V input (typically PC internal regulator output) +12V input (typically automotive) Battery 6.3.1.1 + 5V input Source Power Supply Design Guidelines The desired output for the power supply is 3.8V, hence there's not a big difference between the input source and the desired output and a linear regulator can be used. A switching power supply will not be suited because of the low drop out requirements. When using a linear regulator, a proper heat sink shall be provided in order to dissipate the power generated. A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks close to the GE865, a 100μF tantalum capacitor is usually suited. Make sure the low ESR capacitor on the power supply output (usually a tantalum one) is rated at least 10V. A protection diode should be inserted close to the power input, in order to save the GE865 from power polarity inversion. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 31 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 An example of linear regulator with 5V input is: 6.3.1.2 + 12V input Source Power Supply Design Guidelines The desired output for the power supply is 3.8V, hence due to the big difference between the input source and the desired output, a linear regulator is not suited and shall not be used. A switching power supply will be preferable because of its better efficiency especially with the 2A peak current load represented by the GE865. When using a switching regulator, a 500kHz or more switching frequency regulator is preferable because of its smaller inductor size and its faster transient response. This allows the regulator to respond quickly to the current peaks absorption. In any case the frequency and Switching design selection is related to the application to be developed due to the fact the switching frequency could also generate EMC interferences. For car PB battery the input voltage can rise up to 15,8V and this should be kept in mind when choosing components: all components in the power supply must withstand this voltage. A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks, a 100μF tantalum capacitor is usually suited. Make sure the low ESR capacitor on the power supply output (usually a tantalum one) is rated at least 10V. For Car applications a spike protection diode should be inserted close to the power input, in order to clean the supply from spikes. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 32 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 A protection diode should be inserted close to the power input, in order to save the GE865 from power polarity inversion. This can be the same diode as for spike protection. An example of switching regulator with 12V input is in the below schematic (split in 2 parts): Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 33 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6.3.1.3 Battery Source Power Supply Design Guidelines The desired nominal output for the power supply is 3.8V and the maximum voltage allowed is 4.2V, hence a single 3.7V Li-Ion cell battery type is suited for supplying the power to the Telit GE865 module. WARNING: The three cells Ni/Cd or Ni/MH 3,6 V Nom. battery types or 4V PB types MUST NOT BE USED DIRECTLY since their maximum voltage can rise over the absolute maximum voltage for the GE865 and damage it. NOTE: DON'T USE any Ni-Cd, Ni-MH, and Pb battery types directly connected with GE865. Their use can lead to overvoltage on the GE865 and damage it. USE ONLY Li-Ion battery types. A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks, a 100μF tantalum capacitor is usually suited. Make sure the low ESR capacitor (usually a tantalum one) is rated at least 10V. A protection diode should be inserted close to the power input, in order to save the GE865 from power polarity inversion. Otherwise the battery connector should be done in a way to avoid polarity inversions when connecting the battery. The battery capacity must be at least 500mAh in order to withstand the current peaks of 2A; the suggested capacity is from 500mAh to 1000mAh. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 34 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6.3.2 Thermal Design Guidelines The thermal design for the power supply heat sink should be done with the following specifications: Average current consumption during transmission @ max PWR level: 500mA Average current consumption during transmission @ min PWR level: 150mA Average current during Power Saving (CFUN=5) : 2,4mA Average current during idle (Power Saving disabled): 24mA NOTE: The average consumption during transmissions depends on the power level at which the device is requested to transmit by the network. The average current consumption hence varies significantly. Considering the very low current during idle, especially if Power Saving function is enabled, it is possible to consider from the thermal point of view that the device absorbs current significantly only during calls. If we assume that the device stays into transmission for short periods of time (let's say few minutes) and then remains for a quite long time in idle (let's say one hour), then the power supply has always the time to cool down between the calls and the heat sink could be smaller than the calculated one for 500mA maximum RMS current, or even could be the simple chip package (no heat sink). Moreover in the average network conditions the device is requested to transmit at a lower power level than the maximum and hence the current consumption will be less than the 500mA, being usually around 150mA. For these reasons the thermal design is rarely a concern and the simple ground plane where the power supply chip is placed can be enough to ensure a good thermal condition and avoid overheating. For the heat generated by the GE865, you can consider it to be during transmission 1W max during CSD/VOICE calls and 2W max during class10 GPRS upload. This generated heat will be mostly conducted to the ground plane under the GE865; you must ensure that your application can dissipate it. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 35 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 36 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 6.3.3 Power Supply PCB layout Guidelines As seen on the electrical design guidelines the power supply shall have a low ESR capacitor on the output to cut the current peaks and a protection diode on the input to protect the supply from spikes and polarity inversion. The placement of these components is crucial for the correct working of the circuitry. A misplaced component can be useless or can even decrease the power supply performances. The Bypass low ESR capacitor must be placed close to the Telit GE865 power input pads or in the case the power supply is a switching type it can be placed close to the inductor to cut the ripple provided the PCB trace from the capacitor to the GE865 is wide enough to ensure a dropless connection even during the 2A current peaks. The protection diode must be placed close to the input connector where the power source is drained. The PCB traces from the input connector to the power regulator IC must be wide enough to ensure no voltage drops occur when the 2A current peaks are absorbed. Note that this is not made in order to save power loss but especially to avoid the voltage drops on the power line at the current peaks frequency of 216 Hz that will reflect on all the components connected to that supply, introducing the noise floor at the burst base frequency. For this reason while a voltage drop of 300-400 mV may be acceptable from the power loss point of view, the same voltage drop may not be acceptable from the noise point of view. If your application doesn't have audio interface but only uses the data feature of the Telit GE865, then this noise is not so disturbing and power supply layout design can be more forgiving. The PCB traces to the GE865 and the Bypass capacitor must be wide enough to ensure no significant voltage drops occur when the 2A current peaks are absorbed. This is for the same reason as previous point. Try to keep this trace as short as possible. The PCB traces connecting the Switching output to the inductor and the switching diode must be kept as short as possible by placing the inductor and the diode very close to the power switching IC (only for switching power supply). This is done in order to reduce the radiated field (noise) at the switching frequency (100-500 kHz usually). The use of a good common ground plane is suggested. The placement of the power supply on the board should be done in such a way to guarantee that the high current return paths in the ground plane are not overlapped to any noise sensitive circuitry as the microphone amplifier/buffer or earphone amplifier. The power supply input cables should be kept separate from noise sensitive lines such as microphone/earphone cables. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 37 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 7 Antenna The antenna connection and board layout design are the most important aspect in the full product design as they strongly affect the product overall performances, hence read carefully and follow the requirements and the guidelines for a proper design. 7.1 GSM Antenna Requirements As suggested on the Product Description the antenna and antenna transmission line on PCB for a Telit GE865 device shall fulfil the following requirements: Frequency range Bandwidth Gain Impedance Input power VSWR absolute max VSWR recommended ANTENNA REQUIREMENTS Depending by frequency band(s) provided by the network operator, the customer shall use the most suitable antenna for that/those band(s) 70 MHz in GSM850, 80 MHz in GSM900, 170 MHz in DCS & 140 MHz PCS band 1.4dBi @900 and 3dBi @1800 1.4dBi @850 and 3dBi @1900 50Ω >2W ≤ 10:1 (limit to avoid permanent damage) ≤ 2:1 (limit to fulfil all regulatory requirements) When using the GE865, since there's no antenna connector on the module, the antenna must be connected to the GE865 antenna pad (BGA Ball H5) by means of a transmission line implemented on the PCB. In the case the antenna is not directly connected at the antenna pad of the GE865, then a PCB line is needed in order to connect with it or with its connector. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 38 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 This transmission line shall fulfill the following requirements: ANTENNA LINE ON PCB REQUIREMENTS Characteristic Impedance 50Ω Max Attenuation 0,3 dB Coupling with other signals shall be avoided Cold End (Ground Plane) of antenna shall be equipotential to the GE865 ground pins Furthermore if the device is developed for the US market and/or Canada market, it shall comply with the FCC and/or IC approval requirements: This device is to be used only for mobile and fixed application. In order to re-use the Telit FCC/IC approvals the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter. If antenna is installed with a separation distance of less than 20 cm from all persons or is co-located or operating in conjunction with any other antenna or transmitter then additional FCC/IC testing may be required. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance. Antennas used for this OEM module must not exceed 3dBi gain for mobile and fixed operating configurations. 7.2 GSM Antenna - PCB line Guidelines Make sure that the impedance is 50Ω; Keep line on the PCB as short as possible, since the antenna line loss shall be less than around 0,3 dB; Line geometry should have uniform characteristics, constant cross section, avoid meanders and abrupt curves; Any kind of suitable geometry / structure (Microstrip, Stripline, Coplanar, Grounded Coplanar Waveguide...) can be used for implementing the printed transmission line afferent the antenna; If a Ground plane is required in line geometry, that plane has to be continuous and sufficiently extended, so the geometry can be as similar as possible to the related canonical model; Keep, if possible, at least one layer of the PCB used only for the Ground plane; If possible, use this layer as reference Ground plane for the transmission line; It is wise to surround (on both sides) the PCB transmission line with Ground, avoid having other signal tracks facing directly the antenna line track. Avoid crossing any un-shielded transmission line footprint with other signal tracks on different layers; Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 39 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 The ground surrounding the antenna line on PCB has to be strictly connected to the main Ground Plane by means of via holes (once per 2mm at least), placed close to the ground edges facing line track; Place EM noisy devices as far as possible from GE865 antenna line; Keep the antenna line far away from the GE865 power supply lines; If EM noisy devices are present on the PCB hosting the GE865, such as fast switching ICs, take care of the shielding of the antenna line by burying it inside the layers of PCB and surround it with Ground planes, or shield it with a metal frame cover. If EM noisy devices are not present around the line, the use of geometries like Microstrip or Grounded Coplanar Waveguide has to be preferred, since they typically ensure less attenuation if compared to a Stripline having same length; 7.3 GSM Antenna - Installation Guidelines Install the antenna in a place covered by the GSM signal. If the device antenna is located greater then 20cm from the human body and there are no co-located transmitter then the Telit FCC/IC approvals can be re-used by the end product If the device antenna is located less then 20cm from the human body or there are no co-located transmitter then the additional FCC/IC testing may be required for the end product (Telit FCC/IC approvals cannot be reused) Antenna shall not be installed inside metal cases Antenna shall be installed also according Antenna manufacturer instructions. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 40 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 8 Logic level specifications Where not specifically stated, all the interface circuits work at 2.8V CMOS logic levels. The following table shows the logic level specifications used in the GE865 interface circuits: Absolute Maximum Ratings -Not Functional Parameter Min Max Input level on any digital pin (CMOS 2.8) when on Input level on any digital pin (CMOS 1.8) when on Input voltage on analog pins when on -0.3V +3.1V -0.3V +2.1V -0.3V +3.0 V Operating Range - Interface levels (2.8V CMOS) Level Min Max Input high level Input low level Output high level Output low level 2.1V 3.1V 0V 2.2V 0V 0.5V 3.1V 0.35V For 1.8V signals: Operating Range - Interface levels (1.8V CMOS) Level Min Max Input high level Input low level Output high level Output low level 1.6V 2.0V 0V 1,65V 0V 0.4V 2.0V 0.35V Current characteristics Level Typical Output Current 1mA Input Current 1uA Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 41 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 8.1 Reset signal Signal RESET# Function Phone reset I/O Bga Ball C1 RESET# is used to reset the GE865 . Whenever this signal is pulled low, the GE865 is reset. When the device is reset it stops any operation. After the release of the reset GE865 is unconditionally shut down, without doing any detach operation from the network where it is registered. This behaviour is not a proper shut down because any GSM device is requested to issue a detach request on turn off. For this reason the Reset signal must not be used to normally shutting down the device, but only as an emergency exit in the rare case the device remains stuck waiting for some network response. The RESET# is internally controlled on start-up to achieve always a proper power-on reset sequence, so there's no need to control this pin on start-up. It may only be used to reset a device already on that is not responding to any command. NOTE: Do not use this signal to power off the GE865. Use the ON/OFF signal to perform this function or the AT#SHDN command. Reset Signal Operating levels: Signal RESET Input high RESET Input low Min 1.8V* 0V Max 2.1V 0.2V * this signal is internally pulled up so the pin can be left floating if not used. If unused, this signal may be left unconnected. If used, then it must always be connected with an open collector transistor, to permit to the internal circuitry the power on reset and under voltage lockout functions. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 42 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 9 Serial Ports The serial port on the GE865 is the core of the interface between the module and OEM hardware. 2 serial ports are available on the module: MODEM SERIAL PORT 1 (Main, ASC0) MODEM SERIAL PORT 2 (Auxiliary, ASC1) 9.1 MODEM SERIAL PORT Several configurations can be designed for the serial port on the OEM hardware, but the most common are: RS232 PC com port microcontroller UART @ 2.8V - 3V (Universal Asynchronous Receive Transmit) microcontroller UART @ 5V or other voltages different from 2.8V Depending from the type of serial port on the OEM hardware a level translator circuit may be needed to make the system work. The only configuration that doesn't need a level translation is the 2.8V UART. The serial port on the GE865 is a +2.8V UART with all the 7 RS232 signals. It differs from the PC-RS232 in the signal polarity (RS232 is reversed) and levels. The levels for the GE865 UART are the CMOS levels: Absolute Maximum Ratings -Not Functional Parameter Min Max Input level on any digital pad when on Input voltage on analog pads when on -0.3V +3.1V -0.3V +3.1V Operating Range - Interface levels (2.8V CMOS) Level Min Max Input high level VIH Input low level VIL Output high level VOH 2.1V 3.1 V 0V 0.5V 2.2V 3.1V Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 43 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Output low level VOL 0V 0.35V The signals of the GE865 serial port are: RS232 Pin Number Signal GE865 Pad Number Name DCD - dcd_uart B5 Data Carrier Detect Output from the GE865 that indicates the carrier presence A4 Transmit line *see Note Output transmit line of GE865 UART A3 Receive line *see Note Input receive of the GE865 UART DTR - dtr_uart B3 Data Terminal Ready GND C2, C7, E5, E7, G1, G3, G4, G5, H3, H6 Ground DSR - dsr_uart B2 Data Set Ready RTS -rts_uart A1 Request to Send CTS - cts_uart A2 Clear to Send RI - ri_uart B4 Ring Indicator RXD tx_uart TXD rx_uart Usage Input to the GE865 that controls the DTE READY condition ground Output from the GE865 that indicates the module is ready Input to the GE865 that controls the Hardware flow control Output from the GE865 that controls the Hardware flow control Output from the GE865 that indicates the incoming call condition NOTE: According to V.24, RX/TX signal names are referred to the application side, therefore on the GE865 side these signal are on the opposite direction: TXD on the application side will be connected to the receive line (here named TXD/ rx_uart ) of the GE865 serial port and viceversa for RX. NOTE: For a minimum implementation, only the TXD and RXD lines can be connected, the other lines can be left open provided a software flow control is implemented. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 44 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the GE865 when the module is powered off or during an ON/OFF transition. 9.2 RS232 level translation In order to interface the GE865 with a PC com port or a RS232 (EIA/TIA-232) application a level translator is required. This level translator must: invert the electrical signal in both directions; change the level from 0/2.8V to +15/-15V . Actually, the RS232 UART 16450, 16550, 16650 & 16750 chipsets accept signals with lower levels on the RS232 side (EIA/TIA-562), allowing a lower voltage-multiplying ratio on the level translator. Note that the negative signal voltage must be less than 0V and hence some sort of level translation is always required. The simplest way to translate the levels and invert the signal is by using a single chip level translator. There are a multitude of them, differing in the number of drivers and receivers and in the levels (be sure to get a true RS232 level translator not a RS485 or other standards). By convention the driver is the level translator from the 0-2.8V UART to the RS232 level. The receiver is the translator from the RS232 level to 0-2.8V UART. In order to translate the whole set of control lines of the UART you will need: 5 drivers 3 receivers NOTE: The digital input lines working at 2.8V CMOS have an absolute maximum input voltage of 3.0V; therefore the level translator IC shall not be powered by the +3.8V supply of the module. Instead, it must be powered from a +2.7V / +2.9V (dedicated) power supply. This is because in this way the level translator IC outputs on the module side (i.e. GE865 inputs) will work at +3.8V interface levels, damaging the module inputs. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 45 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 46 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 An example of level translation circuitry of this kind is: The example is done with a SIPEX SP3282EB RS232 Transceiver that could accept supply voltages lower than 3V DC. NOTE: In this case Vin has to be set with a value compatible with the logic levels of the module. (Max 2.9V DC). In this configuration the SP3282EB will adhere to EIA/TIA-562 voltage levels instead of RS232 (-5 ~ +5V). Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 47 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Second solution could be done using a MAXIM transceiver (MAX218) In this case the compliance with RS232 (+-5V) is possible. Another level adapting method could be done using a standard RS232 Transceiver (MAX3237EAI) adding some resistors to adapt the levels on the GE865 Input lines. NOTE: In this case has to be taken in account the length of the lines on the application to avoid problems in case of High-speed rates on RS232. The RS232 serial port lines are usually connected to a DB9 connector with the following layout: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 48 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 9.3 5V UART level translation If the OEM application uses a microcontroller with a serial port (UART) that works at a voltage different from 2.8 - 3V, then a circuitry has to be provided to adapt the different levels of the two set of signals. As for the RS232 translation there are a multitude of single chip translators. For example a possible translator circuit for a 5V TRANSMITTER/RECEIVER can be: TIP: Note that the TC7SZ07AE has open drain output; therefore the resistor R2 is mandatory. NOTE: The UART input line TXD (rx_uart) of the GE865 is NOT internally pulled up with a resistor, so there may be the need to place an external 47KΩ pull-up resistor, either the DTR (dtr_uart) and RTS (rts_uart) input lines are not pulled up internally, so an external pull-up resistor of 47KΩmay be required. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 49 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 NOTE: The input lines working at 2.8VCMOS can be pulled-up with 47KΩ In case of reprogramming of the module has to be considered the use of the RESET line to start correctly the activity. The preferable configuration is having an external supply for the buffer. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 50 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 10 Audio Section Overview The Base Band Chip of the GE865 provides one audio path both in Uplink (transmit) and in Downlink (receive) direction , as shown in the next figure . For more information refer to Telit document : 80000NT10007a Audio Settings Application Note B a seband A ud oi F ron tE nd E a r+ B a al n ced EP P1 E a rp ei ce D r vi e rs 16 Load S ni g el ended 16 Ea r - EP N 1 B ai s MC I + M CI P 1 100nF M CI 1 B a al n ced MC I S ni g el ended 100nF M CI N 1 xgo dl a fe .skd Audio Section Block Diagram Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 51 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 10.1 Electrical Characteristics TIP: Being the microphone circuitry the more noise sensitive, its design and layout must be done with particular care. Both microphone paths are balanced and the OEM circuitry must be balanced designed to reduce the common mode noise typically generated on the ground plane. However the customer can use the unbalanced circuitry for particular application. 10.1.1 Input Lines differential microphone path Line Coupling AC* Line Type Balanced Coupling capacitor ≥ 100nF Differential input resistance 50kΩ Differential input voltage ≤ 1,03Vpp @ MicG=0dB (*) WARNING : AC means that the signals from the microphone have to be connected to input lines of the module through capacitors which value has to be ≥ 100nF. Not respecting this constraint, the input stages will be damaged. WARNING: when particular OEM application needs a Single Ended Input configuration, it is forbidden connecting the unused input directly to Ground, but only through a capacitor which value has to be ≥ 100nF.. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 52 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 10.1.2 Output Lines TIP : We suggest driving the load differentially , thus the output swing will double and the need for the big output coupling capacitor avoided. However if particular OEM application needs, also a Single Ended (S.E) circuitry can be implemented but the output power will be reduced four times. The OEM circuitry shall be designed to reduce the common mode noise typically generated on the ground plane,getting the maximum power output from the device (low resistance tracks). WARNING. When in Single Ended configuration, the unused output line must be left open: if this constraint is not respected, the output stage will be damaged. line coupling single-ended AC differential DC output load resistance ≥ 14 Ω internal output resistance 4 Ω (typical) signal bandwidth 150 ÷4000 Hz @ -3dB max. differential output voltage 1.31 Vrms (typical, open circuit) differential output voltage 328mVrms /16 Ω @ -12dBFS (*) volume increment 2 dB per step volume steps 10 (*) 0dBFS is the normalized overall Analog Gain equal to 3,7Vpp differential Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 53 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11 General Purpose I/O The general purpose I/O pads can be configured to act in three different ways: input output alternate function (internally controlled) Input pads can only be read ; they report the digital value (high or low) present on the pad at the read time . Output pads can only be written or queried and set the value of the pad output. An alternate function pad is internally controlled by the GE865 firmware and acts depending on the function implemented. For Logic levels please refer to chapter 8. The following table shows the available GPIO on the GE865 . Signal I/O Function GPIO_01 I/O GPIO01 Configurable GPIO GPIO_02 I/O GPIO_03 Type Default State ON_OFF state CMOS 2.8V Input / output current 1uA/1mA INPUT State during Reset GPIO02 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT I/O GPIO03 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT GPIO_04 I/O GPIO04 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT GPIO_05 I/O GPIO05 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT Note Alternate function (JDR) Alternate function GPIO_06 I/O GPIO06 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT (RF Transmission Control) Alternate function (RFTXMON) Alternate function (ALARM) Alternate function GPIO_07 I/O GPIO07 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT GPIO_08 I/O GPIO08 Configurable GPIO CMOS 2.8V 1uA/1mA INPUT GPIO_09 I/O GPIO09 Configurable GPIO CMOS 2.8V Open Drain GPIO_10 I/O GPIO10 Configurable GPIO CMOS 2.8V Open Drain (BUZZER) Not all GPIO pads support all these three modes: GPIO2 supports all three modes and can be input, output, Jamming Detect Output (Alternate function) Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 54 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 GPIO4 supports all three modes and can be input, output, RF Transmission Control (Alternate function) GPIO5 supports all three modes and can be input, output, RFTX monitor output (Alternate function) GPIO6 supports all three modes and can be input, output, alarm output (Alternate function) GPIO7 supports all three modes and can be input, output, buzzer output (Alternate function) 11.1 GPIO Logic levels Where not specifically stated, all the interface circuits work at 2.8V CMOS logic levels. The following table shows the logic level specifications used in the GE865 interface circuits: Absolute Maximum Ratings -Not Functional Parameter Min Max Input level on any digital pin when on (CMOS 2.8) Input level on any digital pin when on (CMOS 1.8) Input voltage on analog pins when on -0.3V +3.1V -0.3V +2.1V -0.3V +3.0V Operating Range - Interface levels (2.8V CMOS) Level Min Max Input high level Input low level Output high level Output low level 2.1V 0V 2.2V 0V 3.1V 0.5V 3.1V 0.35V For 1.8V signals: Operating Range - Interface levels (1.8V CMOS) Level Min Max Input high level Input low level Output high level 1.6V 0V 1,65V 2.0V 0.4V 1.85V Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 55 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Output low level 0V 0.35V Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 56 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.2 Using a GPIO Pad as INPUT The GPIO pads, when used as inputs, can be connected to a digital output of another device and report its status, provided this device has interface levels compatible with the 2.8V CMOS levels of the GPIO. If the digital output of the device to be connected with the GPIO input pad has interface levels different from the 2.8V CMOS, then it can be buffered with an open collector transistor with a 47K pull up to 2.8V. NOTE: In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the GE865 when the module is powered off or during an ON/OFF transition. 11.3 Using a GPIO Pad as OUTPUT The GPIO pads, when used as outputs, can drive 2.8V CMOS digital devices or compatible hardware. When set as outputs, the pads have a push-pull output and therefore the pull-up resistor may be omitted. 11.4 Using the RF Transmission Control GPIO4 The GPIO4 pin, when configured as RF Transmission Control Input, permits to disable the Transmitter when the GPIO is set to Low by the application. In the design is necessary to add a pull up resistor (47K to 2.8V); Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 57 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.5 Using the RFTXMON Output GPIO5 The GPIO5 pin, when configured as RFTXMON Output, is controlled by the GE865 module and will rise when the transmitter is active and fall after the transmitter activity is completed. There are 2 different modes for this function: 1) Active during all the calls: For example, if a call is started, the line will be HIGH during all the conversation and it will be again LOW after hanged up. The line rises up 300ms before first TX burst and will became again LOW from 500ms to 1s after last TX burst. 2) Active during all the TX activity: The GPIO is following the TX bursts Please refer to the AT User interface manual for additional information on how to enable this function. 11.6 Using the Alarm Output GPIO6 The GPIO6 pad, when configured as Alarm Output, is controlled by the GE865 module and will rise when the alarm starts and fall after the issue of a dedicated AT command. This output can be used to power up the GE865 controlling microcontroller or application at the alarm time, giving you the possibility to program a timely system wake-up to achieve some periodic actions and completely turn off either the application and the GE865 during sleep periods, dramatically reducing the sleep consumption to few μA. In battery-powered devices this feature will greatly improve the autonomy of the device. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 58 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.7 Using the Buzzer Output GPIO7 The GPIO7 pad, when configured as Buzzer Output, is controlled by the GE865 module and will drive a Buzzer driver with appropriate square waves. This permits to your application to easily implement Buzzer feature with ringing tones or melody played at the call incoming, tone playing on SMS incoming or simply playing a tone or melody when needed. A sample interface scheme is included below to give you an idea of how to interface a Buzzer to the GPIO7: TR2 SMBT2907A +V buzzer R1 4,7K D1 D1N4148 C1 33pF R2 1K GPIO7 TR1 BCR141W NOTE: To correctly drive a buzzer a driver must be provided, its characteristics depend on the Buzzer and for them refer to your buzzer vendor. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 59 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.8 Magnetic Buzzer Concepts 11.8.1 Short Description A magnetic Buzzer is a sound-generating device with a coil located in the magnetic circuit consisting of a permanent magnet, an iron core, a high permeable metal disk and a vibrating diaphragm. Drawing of the Magnetic Buzzer. The disk and diaphragm are attracted to the core by the magnetic field. When an oscillating signal is moved through the coil, it produces a fluctuating magnetic field which vibrates the diaphragm at a frequency of the drive signal. Thus the sound is produced relative to the frequency applied. Diaphragm movement. 11.8.2 Frequency Behaviour The frequency behaviour represents the effectiveness of the reproduction of the applied signals. Because performance is related to a square driving waveform (whose Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 60 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 amplitude varies from 0V to Vpp), if you modify the waveform (e.g. from square to sinus) the frequency response will change. 11.8.3 Power Supply Influence Applying a signal whose amplitude is different from that suggested by the manufacturer, the performance change Because resonance frequency depends on acoustic design, by lowering the amplitude of the driving signal the response bandwidth tends to become narrow, and vice versa. Summarizing: Vpp ↑ fo ↓ Vpp ↓ fo ↑ The risk is that the fo could easily fall outside of new bandwidth; consequently the SPL could be much lower than the expected. WARNING: It is very important to respect the sense of the applied voltage: never apply to the "-" pin a voltage more positive than the "+" pin: if this happens, the diaphragm vibrates in the opposite direction with a high probability to be expelled from its physical position. This damages the device permanently. 11.8.4 Working Current Influence In the component data sheet you will find the value of MAX CURRENT: this represents the maximum average current that can flow at nominal voltage without current limitation. In other words it is not the peak current, which could be twice or three times higher. If driving circuitry does not support these peak values, the SPL will never reach the declared level or the oscillations will stop. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 61 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.9 Indication of network service availability The STAT_LED pin status shows information on the network service availability and Call status. In the GE865 modules, the STAT_LED usually needs an external transistor to drive an external LED. Therefore, the status indicated in the following table is reversed with respect to the pin status. LED status Permanently off Fast blinking (Period 1s, Ton 0,5s) Slow blinking (Period 3s, Ton 0,3s) Permanently on Device Status Device off Net search / Not registered / turning off Registered full service a call is active A schematic example could be: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 62 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 63 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 11.10 RTC Bypass out The VRTC pin brings out the Real Time Clock supply, which is separate from the rest of the digital part, allowing having only RTC going on when all the other parts of the device are off. To this power output a backup capacitor can be added in order to increase the RTC autonomy during power off of the battery. NO Devices must be powered from this pin. 11.11 External SIM Holder Implementation Please refer to the related User Guide (SIM Holder Design Guides, 80000NT10001a). Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 64 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 12 DAC and ADC section 12.1 DAC Converter 12.1.1 Description The GE865 provides a Digital to Analog Converter. The signal (named DAC_OUT) is available on BGA Ball G7 of the GE865 and on pin 17 of PL102 on GE865 Interface Board (CS1324). The on board DAC is a 10 bit converter, able to generate a analogue value based a specific input in the range from 0 up to 1023. However, an external low-pass filter is necessary Voltage range (filtered) Range Min Max 2,6 1023 Units Volt Steps The precision is 10 bits so, if we consider that the maximum voltage is 2V, the integrated voltage could be calculated with the following formula: Integrated output voltage = (2 *value) / 1023 DAC_OUT line must be integrated (for example with a low band pass filter) in order to obtain an analog voltage. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 65 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 12.1.2 Enabling DAC An AT command is available to use the DAC function. The command is: AT#DAC= [[, ]] - scale factor of the integrated output voltage (0..1023 - 10 bit precision) it must be present if =1 Refer to SW User Guide or AT Commands Reference Guide for the full description of this function. NOTE: The DAC frequency is selected internally. D/A converter must not be used during POWERSAVING. 12.1.3 Low Pass Filter Example Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 66 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 12.2 ADC Converter 12.2.1 Description The on board A/D are 11-bit converter. They are able to read a voltage level in the range of 0÷2 volts applied on the ADC pin input, store and convert it into 11 bit word. Input Voltage range AD conversion Resolution Min Max 11 <1 Units Volt bits mV The GE865 module provides 2 Analog to Digital Converters. The input lines are: ADC_IN1 available on Ball F5 and Pin 19 of PL102 on GE865 Interface Board (CS1324). ADC_IN2 available on Ball F6 and Pin 20 of PL102 on GE865 Interface Board (CS1324). 12.2.2 Using ADC Converter An AT command is available to use the ADC function. The command is AT#ADC=1,2 The read value is expressed in mV Refer to SW User Guide or AT Commands Reference Guide for the full description of this function. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 67 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13 Mounting the GE865 on your Board 13.1 General The GE865 modules have been designed in order to be compliant with a standard leadfree SMT process. 13.2 Module finishing & dimensions Pin A1 Lead-free Alloy: Surface finishing Sn/Ag/Cu for all solder pads Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 68 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13.3 Recommended foot print for the application In order to easily rework the GE865 is suggested to consider on the application a 1.5mm Inhibit area around the module. It is also suggested, as common rule for an SMT component, to avoid having a mechanical part of the application in direct contact with the module. NOTE: In the customer application, the region under INHIBIT WIRING *1 (see figure) must be clear from signal or ground paths. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 69 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13.4 Debug of the GE865 in production To test and debug the mounting of the GE865, we strongly recommend to foreseen test pads on the host PCB, in order to check the connection between the GE865 itself and the application and to test the performance of the module connecting it with an external computer. Depending by the customer application, these pads include, but are not limited to the following signals: TXD RXD ON/OFF RESET GND VBATT TX_AUX RX_AUX PWRMON SERVICE 13.5 Stencil a thickness of stencil foil ≥ 120µm. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 70 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13.6 PCB pad design Recommendations for PCB pad dimensions Ball pitch [mm] Solder resist opening diameter A [mm] Metal pad diameter B [mm] 2,4 1,150 1 ± 0.05 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 71 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 It is recommended no microvia without solder resist cover under the module and no microvia around the pads (see following figure). Holes in pad are allowed only for blind holes and not for through holes. Recommendations for PCB pad surfaces: Finish Electro-less Ni / Immersion Au Layer thickness [µm] 3 7/ 0.05 0.15 Properties good solder ability protection, high shear force values The PCB must be able to resist the higher temperatures which are occurring at the leadfree process. This issue should be discussed with the PCB-supplier. Generally, the wettability of tin-lead solder paste on the described surface plating is better compared to lead-free solder paste. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 72 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13.7 Solder paste Solder paste Lead free Sn/Ag/Cu Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 73 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 13.7.1 GE865 Solder reflow The following is the recommended solder reflow profile Profile Feature Average ramp-up rate (TL to TP) Preheat Temperature Min (Tsmin) Temperature Max (Tsmax) Time (min to max) (ts) Tsmax to TL Ramp-up Rate Time maintained above: Temperature (TL) Time (tL) Peak Temperature (Tp) Time within 5°C of actual Peak Temperature (tp) Ramp-down Rate Time 25°C to Peak Temperature Pb-Free Assembly 3°C/second max 150°C 200°C 60-180 seconds 3°C/second max 217°C 60-150 seconds 245 +0/-5°C 10-30 seconds 6°C/second max. 8 minutes max. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 74 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 NOTE: All temperatures refer to topside of the package, measured on the package body surface WARNING: The GE865 module withstands one reflow process only. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 75 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 76 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 14 Packing system The GE865 modules are packaged on trays of 50 pieces each. This is especially suitable for the GE865 according to SMT processes for pick & place movement requirements. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 77 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 NOTE: All temperatures refer to topside of the package, measured on the package body surface WARNING: These trays can withstand at the maximum temperature of 65° C. 14.1 Moisture sensibility J-STD-020, take care all the relatives requirements for using this kind of components. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 78 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 15 Conformity Assessment Issues The Telit GE865 Module has been assessed in order to satisfy the essential requirements of the R&TTE Directive 1999/05/EC (Radio Equipment & Telecommunications Terminal Equipments) to demonstrate the conformity against the harmonised standards with the final involvement of a Notified Body. If the module is installed in conformance to the Telit installation manuals, no further evaluation under Article 3.2 of the R&TTE Directive and do not require further involvement of a R&TTE Directive Notified Body for the final product. In all other cases, or if the manufacturer of the final product is in doubt, then the equipment integrating the radio module must be assessed against Article 3.2 of the R&TTE Directive. In all cases the assessment of the final product must be made against the Essential requirements of the R&TTE Directive Articles 3.1(a) and (b), Safety and EMC respectively, and any relevant Article 3.3 requirements. This Hardware User Guide contain all the information you may need for developing a product meeting the R&TTE Directive. Furthermore the GE865 Module module is FCC Approved as module to be installed in other devices. This device is to be used only for fixed and mobile applications. If the final product after integration is intended for portable use, a new application and FCC is required. The GE865 Module is conforming to the following US Directives: Use of RF Spectrum. Standards: FCC 47 Part 24 (GSM 1900) EMC (Electromagnetic Compatibility). Standards: FCC47 Part 15 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. To meet the FCC's RF exposure rules and regulations: Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 79 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 The system antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all the persons and must not be co-located or operating in conjunction with any other antenna or transmitter. The system antenna(s) used for this module must not exceed 1.4dBi (850MHz) and 3.0dBi (1900MHz) for mobile and fixed or mobile operating configurations. Users and installers must be provided with antenna installation instructions and transmitter operating conditions for satisfying RF exposure compliance. Manufacturers of mobile, fixed or portable devices incorporating this module are advised to clarify any regulatory questions and to have their complete product tested and approved for FCC compliance. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 80 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 16 SAFETY RECOMMANDATIONS READ CAREFULLY Be sure the use of this product is allowed in the country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas: Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, etc Where there is risk of explosion such as gasoline stations, oil refineries, etc It is responsibility of the user to enforce the country regulation and the specific environment regulation. Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the final product; therefore, care has to be taken to the external components of the module, as well as of any project or installation issue, because the risk of disturbing the GSM network or external devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force. Every module has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm). In case of this requirement cannot be satisfied, the system integrator has to assess the final product against the SAR regulation. Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 81 of 82 GE865 Hardware User Guide 1vv0300799 Rev.11 – 13-07-2010 The European Community provides some Directives for the electronic equipments Community website: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm The text of the Directive 99/05 regarding telecommunication equipments is available, while the applicable Directives (Low Voltage and EMC) are available at: http://europa.eu.int/comm/enterprise/electr_equipment/index_en.htm Reproduction forbidden without Telit Communications S.p.A. written authorization - All Rights Reserved page 82 of 82
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 82 Language : it-IT Title : GE865 Harware User Guide Author : F D Creator : Microsoft® Office Word 2007 Create Date : 2010:07:16 10:25:07 Modify Date : 2010:07:16 10:25:07 Producer : Microsoft® Office Word 2007EXIF Metadata provided by EXIF.tools