Telit Communications S p A HE920NA Wireless module User Manual HW User Guide

Telit Communications S.p.A. Wireless module HW User Guide

Contents

Users Manual

                   HE920 Hardware User Guide  1vv0301014 Rev.9 – 2014-01-23
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 2 of 84  APPLICABILITY TABLE  PRODUCT HE920-EU HE920-NA
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 3 of 84  SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE Notice While  reasonable  efforts  have  been  made  to  assure  the  accuracy  of  this  document,  Telit assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked  and is believed  to  be  entirely  reliable.  However,  no  responsibility is assumed  for inaccuracies or omissions. Telit reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Telit does not  assume  any liability arising  out  of  the  application  or  use  of  any  product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It  is  possible  that  this  publication  may  contain  references  to,  or  information  about  Telit products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Telit intends to announce such Telit products, programming, or services in your country. Copyrights This instruction manual and the Telit products described in this instruction manual may be, include  or  describe  copyrighted  Telit  material,  such  as  computer  programs  stored  in semiconductor memories or other media. Laws in the Italy and other countries preserve for Telit  and  its  licensors  certain  exclusive  rights  for  copyrighted  material,  including  the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted  material.  Accordingly,  any  copyrighted  material  of  Telit  and  its  licensors contained  herein  or  in  the  Telit  products  described  in  this  instruction  manual  may  not  be copied,  reproduced,  distributed,  merged  or  modified  in  any  manner  without  the  express written permission of Telit. Furthermore, the purchase of Telit products shall not be deemed to  grant  either  directly  or  by  implication,  estoppel,  or  otherwise,  any  license  under  the copyrights, patents or patent applications of Telit, as arises by operation of law in the sale of a product. Computer Software Copyrights The Telit and 3rd Party supplied Software (SW) products described in this instruction manual may  include  copyrighted  Telit  and  other  3rd  Party  supplied  computer  programs  stored  in semiconductor memories or other media. Laws in the Italy and other countries preserve for Telit  and  other  3rd  Party  supplied  SW  certain  exclusive  rights  for  copyrighted  computer programs, including  the  exclusive right  to  copy  or  reproduce  in  any  form  the  copyrighted computer  program.  Accordingly,  any  copyrighted  Telit  or  other  3rd  Party  supplied  SW computer programs contained in the Telit products described in this instruction manual may not be copied (reverse engineered) or reproduced in any manner without the express written permission of Telit or the 3rd Party SW supplier. Furthermore, the purchase of Telit products shall  not be  deemed  to  grant  either  directly  or  by  implication, estoppel,  or  otherwise,  any license under the copyrights, patents or patent applications of Telit or other 3rd Party supplied SW, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 4 of 84  Usage and Disclosure Restrictions License Agreements The  software  described  in  this  document  is  the  property  of  Telit  and  its  licensors.  It  is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. Copyrighted Materials Software  and  documentation  are  copyrighted  materials.  Making  unauthorized  copies  is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Telit High Risk Materials Components,  units,  or  third-party  products  used  in  the  product  described  herein  are  NOT fault-tolerant and  are  NOT  designed, manufactured, or  intended  for  use  as  on-line  control equipment in the following hazardous environments requiring fail-safe controls: the operation of  Nuclear  Facilities,  Aircraft Navigation  or  Aircraft  Communication  Systems, Air  Traffic Control, Life Support, or Weapons Systems (High Risk Activities"). Telit and its supplier(s) specifically  disclaim  any  expressed  or  implied  warranty  of  fitness  for  such  High  Risk Activities. Trademarks TELIT and the Stylized T Logo are registered in Trademark Office. All other product or service names are the property of their respective owners.   Copyright ©  Telit Communications S.p.A. 2013.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 5 of 84  Contents 1. Introduction ................................................. 9 1.1. Scope ..................................................... 9 1.2. Audience .................................................. 9 1.3. Contact Information, Support .............................. 9 1.4. Document Organization .................................... 10 1.5. Text Conventions ......................................... 11 1.6. Related Documents ........................................ 11 2. General Product Description ................................. 12 2.1. Overview ................................................. 12 2.2. HE920 Mechanical Dimensions .............................. 13 2.3. Weight ................................................... 13 2.4. Environmental requirements ............................... 14 2.4.1. Temperature range .......................................... 14 2.4.2. RoHS compliance ............................................ 14 2.5. Operating Frequency ...................................... 14 3. HE920 Module Connections .................................... 16 3.1. PIN-OUT .................................................. 16 3.1.1. LGA Pads Layout ............................................ 23 4. Hardware Commands ........................................... 25 4.1. Turning ON the HE920 ..................................... 25 4.2. Initialization and Activation state ...................... 25 4.3. Turning OFF the HE920 .................................... 27 4.3.1. Shutdown by Software Command ............................... 28 4.3.2. Hardware Shutdown .......................................... 29 4.4. Hardware Unconditional Restart (RESET) ................... 30 4.5. Hardware Unconditional Shutdown (Power Off) .............. 31 4.6. Summary of Turning ON and OFF the module ................. 32 5. Power Supply ................................................ 33 5.1. Power Supply Requirements ................................ 33 5.2. General Design Rules ..................................... 35
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 6 of 84  5.2.1. Electrical Design Guidelines ............................... 35 5.2.1.1. + 5V Input Source Power Supply Design Guidelines ........ 35 5.2.1.2. + 12V Input Source Power Supply Design Guidelines ....... 36 5.2.1.3. Battery Source Power Supply Design Guidelines ........... 38 5.2.2. Thermal Design Guidelines .................................. 39 5.2.3. Power Supply PCB Layout Guidelines ......................... 40 6. Antenna(s) .................................................. 42 6.1. GSM/WCDMA Antenna Requirements ........................... 42 6.2. GSM/WCDMA Antenna – PCB line Guidelines .................. 43 6.3. GSM/WCDMA Antenna – Installation Guidelines .............. 44 6.4. Antenna Diversity Requirements ........................... 44 6.5. GPS/GNSS Antenna Requirements ............................ 45 6.5.1. Combined GPS/GNSS Antenna .................................. 45 6.5.2. Linear and Patch GPS/GNSS Antenna .......................... 45 6.5.3. LNA and Front End Design Considerations .................... 45 6.5.4. GPS/GNSS Antenna - PCB Line Guidelines ..................... 47 6.5.5. GPS/GNSS Antenna – Installation Guidelines ................. 48 7. Logic Level Specifications .................................. 49 7.1. Reset Signal(Module Restart) ............................. 50 8. USB Port .................................................... 51 9. Serial Ports ................................................ 52 9.1. Modem Serial Port 1 ...................................... 53 9.2. Modem Serial Port 2 ...................................... 54 9.3. RS232 Level Translation .................................. 54 10. Audio Section Overview ...................................... 56 10.1. Analog Audio ........................................... 56 10.2. Digital Audio .......................................... 56 10.2.1. CODEC Example ............................................ 56 11. General Purpose I/O ......................................... 57 11.1. Logic Level Specifications ............................. 58 11.2. Using a GPIO Pad as Input .............................. 58 11.3. Using a GPIO Pad as Output ............................. 59 11.4. Using the Temperature Monitor Function ................. 60
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 7 of 84  11.4.1. Short Description ........................................ 60 11.5. Indication of Network Service Availability ............. 60 11.6. RTC Bypass Out ......................................... 61 11.7. VAUX Power Output ...................................... 61 12. DAC and ADC section ......................................... 62 12.1. DAC Converter .......................................... 62 12.1.1. Description .............................................. 62 12.1.2. Enabling DAC ............................................. 62 12.1.3. Low Pass Filter Example .................................. 63 12.2. ADC Converter .......................................... 63 12.2.1. Description .............................................. 63 12.2.2. Using ADC Converter ...................................... 63 13. Mounting the module on your board ........................... 64 13.1. General ................................................ 64 13.2. Module Finishing & Dimensions .......................... 65 13.3. Recommended foot print for the application ............. 66 13.4. Stencil ................................................ 67 13.5. PCB Pad Design ......................................... 67 13.6. Recommendations for PCB Pad Dimensions (mm) ............ 68 13.7. Solder Paste ........................................... 70 13.7.1. Solder Reflow ............................................ 70 14. Application guide ........................................... 72 14.1. Debug of the HE920 in production ....................... 72 14.2. Bypass capacitor on Power supplies ..................... 73 14.3. SIM interface .......................................... 74 14.3.1. SIM schematic example .................................... 74 14.4. EMC recommendations .................................... 75 14.5. Download and Debug Port ................................ 76 15. Packing system .............................................. 77 15.1. Tray Drawing ........................................... 77 15.2. Moisture Sensibility ................................... 77 16. Conformity Assessment Issues ................................ 79
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 8 of 84  16.1. 1999/5/EC Directive .................................... 79 16.2. FCC/IC Regulatory notices .............................. 81 17. Safety Recommendations ...................................... 83 18. Document History ............................................ 84
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 9 of 84  1. Introduction 1.1. Scope The aim of this document is the description of some hardware solutions useful for developing a product with the Telit HE920-EU/NA module. All the features and solutions detailed are applicable to all HE920, whereas “HE920” is intended the modules listed in the applicability table. When a specific feature is applicable to a specific product, it will be clearly highlighted. 1.2. Audience This document is intended for Telit customers, who are integrators, about to implement their applications using our HE920 module. 1.3. Contact Information, Support For general contact, technical support, to report documentation errors and to order manuals, contact Telit’s Technical Support Center (TTSC) at: TS-EMEA@telit.com TS-NORTHAMERICA@telit.com TS-LATINAMERICA@telit.com TS-APAC@telit.com Alternatively, use:  http://www.telit.com/en/products/technical-support-center/contact.php For detailed information about where you can buy the Telit modules or for recommendations on accessories and components visit:  http://www.telit.com To  register  for  product  news  and  announcements  or  for  product  questions  contact  Telit’s Technical Support Center (TTSC). Our aim is to make this guide as helpful as possible. Keep us informed of your comments and suggestions for improvements. Telit appreciates feedback from the users of our information.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 10 of 84  1.4. Document Organization  This document contains the following chapters:  Chapter 1: “Introduction” provides a scope for this document, target audience, contact and support information, and text conventions.  Chapter 2: “General Product Description”  gives an overview of the features of the product.  Chapter 3: “HE920 Module Connections” deals with the pin out configuration and layout.  Chapter 4: “Hardware Commands” How to control the module via hardware  Chapter 5: “Power Supply” deals on supply and consumption.  Chapter 6: “Antenna” The antenna connection and board layout design are the most important parts in the full product design  Chapter 7: “Logic Level specifications” Specific values adopted in the implementation of logic levels for this module.            Chapter 8: “USB Port”    Chapter 9: “Serial Ports”    Chapter 10: “Audio Section Overview”    Chapter 11: “General Purpose I/O” How the general purpose I/O pads can be configured.  Chapter 12 “DAC and ADC Section” Deals with these two kind of converters.  Chapter 13: “Mounting the module on your board”    Chapter 14: “Application Guides”    Chapter 15: “Packing System”    Chapter 16: “Conformity Assessments Issues”    Chapter 17: “Safety Recommendations”    Chapter 18: “Document History”
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 11 of 84  1.5. Text Conventions  Danger – This information MUST be followed or catastrophic equipment failure or bodily injury may occur.  Caution or Warning – Alerts the user to important points about integrating the module, if these points are not followed, the module and end user equipment may fail or malfunction.  Tip  or  Information  –  Provides  advice  and  suggestions  that  may  be  useful  when integrating the module.  All dates are in ISO 8601 format, i.e. YYYY-MM-DD. 1.6. Related Documents   HE920 Product Description, 80404ST10112A  HE920 Software User guide, 1vv0301015  HE920 AT command reference guide, 80404ST10113A  xE920_Audio_Settings_Application_Note, 80404NT10095A  Telit_UE_HE910V2_DE_CE910_HE920_DVI_Application_Note, 8000010101A  Telit EVK2 User Guide, 1vv0300704
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 12 of 84  2. General Product Description 2.1. Overview  The aim of this document is the description of some hardware solutions useful for developing a product with the Telit HE920 module. In this document all the basic functions of a mobile phone will be taken into account; for each one of them a proper hardware solution will be suggested and eventually the wrong solutions and common errors to be avoided will be evidenced. Obviously this document cannot embrace the whole hardware solutions and products that may be designed. The wrong solutions to be avoided must be considered as mandatory, while the suggested hardware configurations must not be considered mandatory, instead the information given must be used as a guide and a starting point for properly developing your product with the Telit HE920 module. . NOTICE: The integration of the GSM/GPRS/EGPRS/WCDMA/HSPA+ HE920 cellular module within user application must be done according to the design rules described in this manual.     The information presented in this document is believed to be accurate and reliable. However, no responsibility is assumed by Telit Communication S.p.A. for its use, such as any infringement of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent rights of Telit Communication S.p.A. other than for circuitry embodied in Telit products. This document is subject to change without notice.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 13 of 84   2.2. HE920 Mechanical Dimensions The Telit HE920 module overall dimensions are:  •  Length:   34 mm •  Width:    40 mm •  Thickness:   2.8 mm  2.3. Weight  The module weight of HE920-EU/NA is about 9.0 gram.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 14 of 84  2.4. Environmental requirements 2.4.1. Temperature range    Note Operating Temperature Range –20°C ~ +55°C The  module  is  fully  functional(*)  in  all  the temperature range, and it fully meets the ETSI specifications. –40°C ~ +85°C The  module  is  fully  functional(*)  in  all  the temperature  range.  Temperatures  outside  of the  range  –20°C  ÷  +55°C  might  slightly deviate from ETSI specifications. Storage and non-operating Temperature Range –40°C ~ +90°C  (*)Functional: the module is able to make and receive voice calls, data calls and SMS.  2.4.2. RoHS compliance As a part of Telit’s corporate policy of environmental protection, the HE920 complies with the  RoHS  (Restriction  of  Hazardous  Substances)  directive  of  the  European  Union  (EU directive 2011/65/EU).
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 15 of 84  2.5. Operating Frequency The operating frequencies in GSM850, EGSM900, DCS1800, PCS1900, WCDMA modes are conformed to the 3GPP specifications. Mode Freq. TX (MHz) Freq. RX (MHz) Channels TX - RX offset GSM850 824.2 ~ 848.8  869.2 ~ 893.8 128 ~ 251 45 MHz EGSM900 890.0 ~ 914.8 935.0 ~ 959.8 0 ~ 124 45 MHz 880.2 ~ 889.8 925.2 ~ 934.8 975 ~ 1023 45 MHz DCS1800 1710.2 ~ 1784.8 1805.2 ~ 1879.8 512 ~ 885 95MHz PCS1900 1850.2 ~ 1909.8 1930.2 ~ 1989.8 512 ~ 810 80MHz WCDMA850 826.4 ~ 846.6 871.4 ~ 891.6 Tx: 4132 ~ 4233 Rx: 4357 ~ 4458 45MHz WCDMA900 (HE920-EU only) 882.4 ~ 912.6 927.4 ~ 957.6 Tx: 2712 ~ 2863 Rx: 2937 ~ 3088 45MHz WCDMA(AWS) (HE920-NA only) 1712.4 ~ 1752.6 2112.4 ~ 2152.6 Tx: 1312 ~ 1513 Rx: 1537 ~ 1738 400MHz WCDMA1900 (HE920-NA only) 1852.4 ~ 1907.6 1932.4 ~ 1987.6 Tx: 9262 ~ 9538 Rx: 9662 ~ 9938 80MHz WCDMA2100 (HE920-EU only) 1922.4 ~ 1977.6 2112.4 ~ 2167.6 Tx: 9612 ~ 9888 Rx: 10562 ~ 10838 190MHz
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 16 of 84  3. HE920 Module Connections 3.1. PIN-OUT  PAD Signal I/O Function Type COMMENT USB HS 2.0 Communication Port D19 USB_D+ I/O USB differential Data(+)   F19 USB_D- I/O USB differential Data(-)   B19 USB_ID(TBD) AI Analog input used to sense whether a peripheral device is connected, and  determine the peripheral type, a host  or a peripheral Analog  A18 USB_VBUS AI Power sense for the internal USB transceiver 5V  Asynchronous UART – Prog. / data +HW Flow Control AH19 C103/TXD I Serial data input (TXD) from DTE 1.8V  AF19 C104/RXD O Serial data output to DTE 1.8V  AC18 C108/DTR I Input for Data terminal ready signal (DTR) from DTE 1.8V  AA18 C105/RTS I Input for Request to send signal (RTS) from DTE 1.8V  AK19 C106/CTS O Output for Clear to send signal (CTS) to DTE 1.8V  AE18 C109/DCD O Output for Data carrier detect signal (DCD) to DTE 1.8V  AG18 C107/DSR O Output for Data set ready signal (DSR) to DTE 1.8V  AJ18 C125/RING O Output for Ring indicator signal (RI) to DTE 1.8V  Asynchronous Auxiliary UART AB19 TXD_AUX O Auxillary UART (TX Data to DTE) 1.8V  AD19 RXD_AUX I Auxillary UART (RX Data from DTE) 1.8V  SIM Card Interface A10 SIMCLK O External SIM signal – Clock 1.8/2.85V  B11 SIMRST O External SIM signal – Reset 1.8/2.85V  B9 SIMIO I/O External SIM signal - Data I/O 1.8/2.85V  B7 SIMIN I External SIM signal - Presence (active low) 1.8V  A8 SIMVCC - External SIM signal – Power supply for the SIM 1.8/2.85V  Audio B5 EAR1_MT+ AO Earphone signal output1, phase + Audio  A4 EAR1_MT- AO Earphone signal output1, phase - Audio  B3 MIC1_MT+ AI Mic signal input1, phase + Audio  A2 MIC1_MT- AI Mic signal input1, phase - Audio  E2 EAR2_MT+ AO Earphone signal output2, phase + Audio  D1 EAR2_MT- AO Earphone signal output2, phase - Audio  C2 MIC2_MT+ AI Mic signal input2, phase + Audio  B1 MIC2_MT- AI Mic signal input2, phase - Audio  Digital Voice interface (DVI) D11 DVI_WA0 I/O Digital Voice interface (WA0) 1.8V
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 17 of 84  PAD Signal I/O Function Type COMMENT C8 DVI_RX I/O Digital Voice interface (RX) 1.8V  D9 DVI_TX I/O Digital Voice interface (TX) 1.8V  C10 DVI_CLK I/O Digital Voice interface (CLK) 1.8V  Digital IO F9 GPIO_01 I/O GPIO_01 1.8V  E10 GPIO_02 I/O GPIO_02 1.8V  F11 GPIO_03 I/O GPIO_03 1.8V  E12 GPIO_04 I/O GPIO_04 1.8V  F13 GPIO_05 I/O GPIO_05 1.8V  E14 GPIO_06 I/O GPIO_06 / DAC_OUT(PDM) 1.8V  R18 GPIO_07 I/O GPIO_07 1.8V  S19 GPIO_08 I/O GPIO_08 1.8V  U19 GPIO_09 I/O GPIO_09 1.8V  W19 GPIO_10 I/O GPIO_10 1.8V  RF Section AD1 Antenna I/O GSM/EDGE/UMTS Antenna (50Ohm) RF  AU9 ANT_DIV I UMTS Antenna Diversity Input (50Ohm) RF  GPS Section S1 ANT_GPS I GPS Antenna (50Ohm) RF  V2 GPS_LNA_EN O Output enable for External LNA supply 1.8V  Miscellaneous Function AP1 RESET* I Reset Input 1.8V Active Low AS1 ON_OFF* I Input Command for Power ON/OFF 1.8V Active Low F17 VRTC AI VRTC Backup Capacitor Power To be used to back  up  the RTC section P17 VAUX/PWRMON O Supply  Output  for  External  Accessories  /  Power  ON Monitor 1.8V  D5 ADC_IN1 AI Analog/Digital Converter Input 1 Analog  E6 ADC_IN2 AI Analog/Digital Converter Input 2 Analog  AU3 STAT_LED O Status Indicator LED 1.8V  AN10 SW_RDY O Indicates that the boot sequence completed successfully 1.8V  AN12 SHDN* I Unconditional Shut down Input 1.8V  M17 LED_DRV_EN O Enable for the external LED Driver circuit 1.8V  Power Supply AP17 VBATT - Main Power Supply (Baseband) Power  AP19 VBATT - Main Power Supply (Baseband) Power  AR18 VBATT - Main Power Supply (Baseband) Power  AS17 VBATT_PA - Main Power Supply (PAM) Power  AS19 VBATT_PA - Main Power Supply (PAM) Power  AT18 VBATT_PA - Main Power Supply (PAM) Power
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 18 of 84  PAD Signal I/O Function Type COMMENT AU17 VBATT_PA - Main Power Supply (PAM) Power  AU19 VBATT_PA - Main Power Supply (PAM) Power  A6 GND - Ground   A12 GND - Ground   B13 GND - Ground   B15 GND - Ground   B17 GND - Ground   C4 GND - Ground   C6 GND - Ground   D3 GND - Ground   D7 GND - Ground   E18 GND - Ground   F1 GND - Ground   G18 GND - Ground   H19 GND - Ground   M1 GND - Ground   N2 GND - Ground   P1 GND - Ground   P3 GND - Ground   R2 GND  Ground   T2 GND  Ground   T18 GND - Ground   U1 GND - Ground   V18 GND - Ground   W1 GND - Ground   X2 GND - Ground   X18 GND - Ground   Y1 GND - Ground   Y19 GND  Ground   AA2 GND - Ground   AB1 GND - Ground   AC2 GND - Ground   AE2 GND - Ground   AF1 GND - Ground   AG2 GND - Ground   AH1 GND - Ground   AJ2 GND - Ground   AK1 GND - Ground   AK17 GND - Ground   AL18 GND - Ground   AM17 GND - Ground
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 19 of 84  PAD Signal I/O Function Type COMMENT AM19 GND - Ground   AN16 GND - Ground   AN18 GND - Ground   AP3 GND - Ground   AP5 GND - Ground   AP7 GND - Ground   AP9 GND - Ground   AP11 GND - Ground   AP13 GND - Ground   AP15 GND - Ground   AR2 GND - Ground   AR4 GND - Ground   AR6 GND - Ground   AR8 GND - Ground   AR10 GND - Ground   AR12 GND - Ground   AR14 GND - Ground   AR16 GND - Ground   AS5 GND - Ground   AS7 GND - Ground   AS9 GND - Ground   AS11 GND - Ground   AS13 GND - Ground   AS15 GND - Ground   AT4 GND - Ground   AT6 GND - Ground   AT8 GND - Ground   AT10 GND - Ground   AT12 GND - Ground   AT14 GND - Ground   AT16 GND - Ground   AU1 GND - Ground   AU5 GND - Ground   AU7 GND - Ground   AU11 GND - Ground   AU15 GND - Ground   Reserved A14 Reserved - Reserved   A16 Reserved - Reserved   C12 Reserved - Reserved   C14 Reserved - Reserved
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 20 of 84  PAD Signal I/O Function Type COMMENT C16 Reserved - Reserved   C18 Reserved - Reserved   D13 Reserved - Reserved   D15 Reserved - Reserved   D17 Reserved - Reserved   E4 Reserved - Reserved   E8 Reserved - Reserved   E16 Reserved - Reserved   F3 Reserved - Reserved   F5 Reserved - Reserved   F7 Reserved - Reserved   F15 Reserved - Reserved   G2 Reserved - Reserved   H1 Reserved - Reserved   H3 Reserved - Reserved   H17 Reserved - Reserved   J2 Reserved - Reserved   J18 Reserved - Reserved   K1 Reserved - Reserved   K3 Reserved - Reserved   K17 Reserved - Reserved   K19 Reserved - Reserved   L2 Reserved - Reserved   L18 Reserved - Reserved   M3 Reserved - Reserved   M19 Reserved - Reserved   N18 Reserved - Reserved   P19 Reserved - Reserved   S3 Reserved - Reserved   S17 Reserved - Reserved   U3 Reserved - Reserved     U17 Reserved - Reserved   W3 Reserved - Reserved   W17 Reserved - Reserved   Y3 Reserved - Reserved   Y17 Reserved - Reserved   AB3 Reserved - Reserved   AB17 Reserved - Reserved   AD3 Reserved - Reserved   AD17 Reserved - Reserved   AF3 Reserved - Reserved
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 21 of 84  PAD Signal I/O Function Type COMMENT AF17 Reserved - Reserved   AH3 Reserved - Reserved   AH17 Reserved - Reserved   AK3 Reserved - Reserved   AL2 Reserved - Reserved   AM1 Reserved - Reserved   AM3 Reserved - Reserved   AN2 Reserved - Reserved   AN4 Reserved - Reserved   AN6 Reserved - Reserved   AN8 Reserved - Reserved   AN14 Reserved - Reserved   AS3 Reserved - Reserved   AT2 Reserved - Reserved   AU13 Reserved - Reserved    NOTE:  DTR pin must be connected in order to enter HE920’s power saving mode.  NOTE: RI pin must be connected in order to wake up the host when a call is coming in sleep mode of host.  NOTE:  RESERVED pins must not be connected RTS must be connected to the GND (on the module side) if flow control is not used   NOTE: If not used, almost all pins must be left disconnected. The only exceptions are the following:  PAD Signal AP17,AP19,AR18,AS17,AS19,AT18,AU17,AU19 VBATT & VBATT_PA A6,A12,B13,B15,B17,C4,C6,D3,D7,E18,F1,G18,H19,M1,N2,P1,P3,R2,T2,T18,U1,V18,W1,X2,X18,Y1,Y19,AA2,AB1,AC2,AE2,AF1,AG2,AH1,AJ2,AK1,AK17, AL18,AM17,AM19,AN16,AN18,AP3,AP5,AP7,AP9, AP11,AP13,AP15,AR2,AR4AR6,AR8,AR10,AR12, AR14,AR16,AS5,AS7,AS9,AS11,AS13,AS15,AT4, AT6,AT8,AT10,AT12,AT14,AT16,AU1,AU5,AU7, AU11,AU15 GND
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 22 of 84  AS1 ON/OFF* AP1 RESET* D19 USB_D+ F19 USB_D- A18 USB_VBUS AH19 C103/TXD AF19 C104/RXD AA18 C105/RTS AK19 C106/CTS AB19 TXD_AUX AD19 RXD_AUX
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 23 of 84  3.1.1. LGA Pads Layout
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 24 of 84  NOTE: The  pin  defined  as  RES  has  to  be  considered  RESERVED  and  not connected  on  any  pin  in  the  application.  The  related  area  on the application has to be kept empty.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 25 of 84  4. Hardware Commands 4.1. Turning ON the HE920 To turn on HE920, the pad ON_OFF* must be tied low for at least 1 second and then released. The maximum current that can be drained from the ON_OFF* pad is 0.1 mA.  A simple circuit to power on the module is illustrated below:   4.2. Initialization and Activation state Upon turning on HE920 module, The HE920 is not activated yet because the boot sequence of HE920 is still going on internally. It takes about 10 seconds to complete the initializing the module internally. For this reason, it would be useless to try to access HE920 during the Initialization state as below. To get the desirable stability, The HE920 needs at least 10 seconds after the PWRMON goes High to become operational by reaching the activation state.    During the Initialization state, any kind of AT-command is not available. DTE must be waiting for the Activation state to communicate with HE920.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 26 of 84  NOTE:  To check if the HE920 has powered on, the hardware line PWRMON must be monitored. When PWRMON goes high, the module has powered on. NOTE:  Do not use any pull up resistor on the ON_OFF* line, it is internally pulled up. Using pull up resistor may bring to latch up problems on the HE920 power regulator and improper power on/off of the module. The line ON_OFF* must be connected only in open collector configuration. NOTE:  In this document all the lines are inverted. Active low signals are labeled with a name that ends with "#", "*" or with a bar over the name.  NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.  For example: 1- Let us assume you need to drive the ON_OFF* pad with a totem pole output of a +1.8/5 V microcontroller (uP_OUT1):
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 27 of 84  4.3. Turning OFF the HE920 Turning off the device can be done in two ways:  by software command (see HE920 Software User Guide)  by Hardware shutdown(pad ON_OFF*) When the device is shut down by software command or by hardware shutdown(pad  ON_OFF*), it issues to the network a detach request that informs the network that the device will not be reachable any more.  TIP:  To check if the device has powered off, hardware line PWRMON must be monitored. When PWRMON goes low it can be considered the device has powered off.  NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 28 of 84  4.3.1. Shutdown by Software Command HE920 can be shut down by a software command. When a shut down command is sent, HE920 goes into the finalization state and finally will shut down PWRMON at the end of this state. The period of the finalization state can differ according to the situation in which the HE920 is so it cannot be fixed definitely. Normally it will be above 10 seconds later from sending a shut down command and DTE should monitor the status of PWRMON to see the actual power off.   TIP:  To check if the device has powered off, hardware line PWRMON must be monitored. When PWRMON goes low, the device has powered off.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 29 of 84  4.3.2. Hardware Shutdown To turn OFF HE920 the pad ON_OFF* must be tied low for at least 2 seconds and then released. Same circuitry and timing for the power on must be used. When the hold time of ON_OFF* is above 2 seconds, HE920 goes into the finalization state and finally will shut down PWRMON at the end of this state. The period of the finalization state can differ according to the situation in which the HE920 is so it cannot be fixed definitely. Normally it will be above 10 seconds later from releasing ON_OFF* and DTE should monitor the status of PWRMON to see the actual power off.   TIP:  To check if the device has powered off, hardware line PWRMON must be monitored. When PWRMON goes low, the device has powered off.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 30 of 84  4.4. Hardware Unconditional Restart (RESET)  To unconditionally restart HE920, the pad RESET* must be tied low for at least 200 milliseconds and then released. A simple circuit to do it is:                      NOTE:  Do not use any pull up resistor on the RESET* line or any totem pole digital output. Using pull up resistor may bring to latch up problems on the HE920 power regulator and improper functioning of the module. The line RESET* must be connected only in open collector configuration. TIP:  The unconditional hardware Restart must always be implemented on the boards and the software must use it as an emergency exit procedure.    RESET# Unconditional Restart impulse   GND
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 31 of 84  For example: 1- Let us assume you need to drive the RESET* pad with a totem pole output of a +1.8/5 V microcontroller (uP_OUT2):      4.5. Hardware Unconditional Shutdown (Power Off) The Unconditional Shutdown of the module could be activated using the SHDN* line (pad AN12).  WARNIG: The  hardware  unconditional  Shutdown  must  not  be  used  during  normal  operation  of  the device since it does not detach the device from the network. It shall be kept as an emergency exit procedure.   To unconditionally shutdown the HE920, the pad SHDN* must be tied low for at least 200 milliseconds and then released.    10k +1.8 / 5V
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 32 of 84     4.6. Summary of Turning ON and OFF the module Below chart describes the overall sequences for Turning ON and OFF.    NOTE:  Do not use any pull up resistor on the SHDN* line nor any totem pole digital output. Using pull up resistor may bring to latch up problems on the HE920 power regulator and improper functioning of the module. The line SHDN* must be connected only in open collector configuration. The SHDN* is generating an unconditional shutdown(power off) of the module without an automatic restart. The module will shutdown, but will NOT perform the detach from the cellular network. To proper power on again the module please refer to the related paragraph (“Turning ON the HE920”)  TIP:  The unconditional hardware shutdown must always be implemented on the boards and should be used only as an emergency exit procedure.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 33 of 84  5. Power Supply The power supply circuitry and board layout are a very important part in the full product design and they strongly reflect on the product overall performances. Read carefully the requirements and the guidelines that will follow for a proper design. 5.1. Power Supply Requirements The HE920 power requirements are: Power Supply Nominal Supply Voltage 3.8V Max Supply Voltage 4.2V Supply Voltage Range 3.4V – 4.2V  HE920 Mode Average(mA) Mode Description IDLE mode Standby mode; no call in progress AT+CFUN=1 WCDMA 15 Normal mode; full functionality of the module GSM 15 AT+CFUN=4 WCDMA 13 Disabled TX and RX; modules is not registered on the network GSM 13 AT+CFUN=0 or AT+CFUN=5 WCDMA 3.2/1.0* Power saving; CFUN=0 module registered on the network and can receive voice call or an SMS; but it is not possible to send AT commands; module wakes up with an unsolicited code (call or SMS) or rising RTS line. CFN=5 full functionality with power saving; Module registered on the network can receive  incoming call sand SMS GSM 3.2/1.3* WCDMA TX and RX mode  WCDMA Voice 630 WCDMA voice channel HSPA 640 HSPA data channel  GSM TX and RX mode  GSM Voice 260 GSM voice channel GPRS Class33 680 GPRS data channel EDGE Class33 380 EDGE data channel GPRS Class10 490 GPRS data channel EDGE Class10 280 EDGE data channel  * Worst/best case depends on network configuration and is not under module control.  TIP:  The electrical design for the Power supply must be made ensuring that it will be capable of a peak current output of at least 2A.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 34 of 84  In GSM/GPRS mode, RF transmission is not continuous and it is packed into bursts at a base frequency of about 216 Hz, and the relative current peaks can be as high as about 2A. Therefore the power supply has to be designed in order to withstand these current peaks without big voltage drops; this means that both the electrical design and the board layout must be designed for this current flow. If the layout of the PCB is not well designed, a strong noise floor is generated on the ground; this will reflect on all the audio paths producing an audible annoying noise at 216 Hz; if the voltage drops during the peak, current absorption is too much. The device may even shut down as a consequence of the supply voltage drop.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 35 of 84  5.2. General Design Rules The principal guidelines for the Power Supply Design embrace three different design steps:  the electrical design  the thermal design  the PCB layout 5.2.1. Electrical Design Guidelines The electrical design of the power supply depends strongly on the power source where this power is drained. We will distinguish them into three categories:  +5V input  (typically PC internal regulator output)  +12V input (typically automotive)  battery 5.2.1.1. + 5V Input Source Power Supply Design Guidelines  The desired output for the power supply is 3.8V, hence there is not a big difference between the input source and the desired output and a linear regulator can be used. A switching power supply will not be suited because of the low drop-out requirements.  When using a linear regulator, a proper heat sink must be provided in order to dissipate the power generated.  A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks close to HE920, a 100μF tantalum capacitor is usually suited.  Make sure the low ESR capacitor on the power supply output (usually a tantalum one) is rated at least 10V.  A protection diode must be inserted close to the power input, in order to save HE920 from power polarity inversion.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 36 of 84  An example of linear regulator with 5V input is:  5.2.1.2. + 12V Input Source Power Supply Design Guidelines  The desired output for the power supply is 3.8V, hence due to the big difference between the input source and the desired output, a linear regulator is not suited and must not be used. A switching power supply will be preferable because of its better efficiency especially with the 2A peak current load represented by HE920.   When using a switching regulator, a 500kHz or more switching frequency regulator is preferable because of its smaller inductor size and its faster transient response. This allows the regulator to respond quickly to the current peaks absorption.   In any case, the frequency and Switching design selection is related to the application to be developed due to the fact the switching frequency could also generate EMC interferences.  For car PB battery the input voltage can rise up to 15.8V and this must be kept in mind when choosing components: all components in the power supply must withstand this voltage.  A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks. A 100μF tantalum capacitor is usually suited for this.  Make sure the low ESR capacitor on the power supply output (usually a tantalum one) is rated at least 10V.  For Car applications a spike protection diode must be inserted close to the power input, in order to clean the supply from spikes.   A protection diode must be inserted close to the power input, in order to save HE920 from power polarity inversion. This can be the same diode as for spike protection.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 37 of 84  An example of switching regulator with 12V input is in the below schematic (it is split in 2 parts):  Switching regulator
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 38 of 84   5.2.1.3. Battery Source Power Supply Design Guidelines  The desired nominal output for the power supply is 3.8V and the maximum allowed voltage is 4.2V, hence a single 3.7V Li-Ion cell battery type is suited for supplying the power to the Telit HE920 module. The three cells Ni/Cd or Ni/MH 3.6 V Nom. battery types or 4V PB types must not be used directly since their maximum voltage can rise over the absolute maximum voltage for HE920 and damage it. NOTE:  Do not use any Ni-Cd, Ni-MH, and Pb battery types directly connected with HE920. Their use can lead to overvoltage on HE920 and damage it. Use only Li-Ion battery types.   A Bypass low ESR capacitor of adequate capacity must be provided in order to cut the current absorption peaks, a 100μF tantalum capacitor is usually suited.  Make sure the low ESR capacitor (usually a tantalum one) is rated at least 10V.  A protection diode must be inserted close to the power input, in order to save HE920 from power polarity inversion. Otherwise the battery connector must be done in a way to avoid polarity inversions when connecting the battery.  The battery capacity must be at least 500mAh in order to withstand the current peaks of 2A; the suggested capacity is from 500mAh to 1000mAh.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 39 of 84  5.2.2. Thermal Design Guidelines The thermal design for the power supply heat sink must be done with the following specifications:  Average current consumption during HSPA transmission @PWR level max in HE920:  640mA  Average current consumption during class33 GPRS transmission @PWR level max: 680mA   Average current consumption during class10 GPRS transmission @PWR level max: 490mA   Average GPS current during GPS ON (Power Saving disabled) : 65mA NOTE:  The average consumption during transmissions depends on the power level at which the device is requested to transmit via the network. The average current consumption hence varies significantly. NOTE:  The thermal design for the Power supply must be made keeping an average consumption at the max transmitting level during calls of 640mA(HSPA)/680mA(GPRS) rms plus 65mA rms for GPS in tracking mode.  Considering the very low current during idle, especially if Power Saving function is enabled, it is possible to consider from the thermal point of view that the device absorbs current significantly only during calls.  If we assume that the device stays in transmission for short periods of time (let us say few minutes) and then remains for quite a long time in idle (let us say one hour), then the power supply has always the time to cool down between the calls and the heat sink could be smaller than the calculated for 640mA (HSPA)/680mA (GPRS) maximum RMS current. There could even be a simple chip package (no heat sink). Moreover in average network conditions the device is requested to transmit at a lower power level than the maximum and hence the current consumption will be less than 640mA (HSPA) /680mA (GPRS) (being usually around 250mA). For these reasons the thermal design is rarely a concern and the simple ground plane where the power supply chip is placed can be enough to ensure a good thermal condition and avoid overheating. For the heat generated by the HE920, you can consider it to be during transmission 2W max during class33 GPRS upload.  This generated heat will be mostly conducted to the ground plane under the HE920; you must ensure that your application can dissipate heat. In the WCDMA/HSPA mode, since HE920 emits RF signals continuously during transmission, you must pay special attention how to dissipate the heat generated. The current consumption will be up to about 640mA in HSPA (630mA in WCDMA) continuously at the maximum TX output power (23dBm). Thus, you must arrange the PCB
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 40 of 84  area as large as possible under HE920 which you will mount. You must mount HE920 on the large ground area of your application board and make many ground vias to dissipate the heat. The peak current consumption in the GSM mode is higher than that in WCDMA. However, considering the heat sink is more important in case of WCDMA. As mentioned before, a GSM signal is bursty, thus, the temperature drift is more insensible than WCDMA. Consequently, if you prescribe the heat dissipation in the WCDMA mode, you don’t need to think more about the GSM mode. 5.2.3. Power Supply PCB Layout Guidelines As seen in the electrical design guidelines, the power supply must have a low ESR capacitor on the output to cut the current peaks and a protection diode on the input to protect the supply from spikes and polarity inversion. The placement of these components is crucial for the correct working of the circuitry. A misplaced component can be useless or can even decrease the power supply performances.  The Bypass low ESR capacitor must be placed close to the Telit HE920 power input pads, or in the case the power supply is a switching type, it can be placed close to the inductor to cut the ripple if the PCB trace from the capacitor to HE920 is wide enough to ensure a drop-less connection even during the 2A current peaks.  The protection diode must be placed close to the input connector where the power source is drained.  The PCB traces from the input connector to the power regulator. IC must be wide enough to ensure no voltage drops to occur when the 2A current peaks are absorbed. Note that this is not made in order to save power loss but especially to avoid the voltage drops on the power line at the current peaks frequency of 216 Hz that will reflect on all the components connected to that supply (also introducing the noise floor at the burst base frequency.) For this reason while a voltage drop of 300-400 mV may be acceptable from the power loss point of view, the same voltage drop may not be acceptable from the noise point of view. If your application does not have audio interface but only uses the data feature of the Telit HE920, then this noise is not so disturbing and power supply layout design can be more forgiving.  The PCB traces to HE920 and the Bypass capacitor must be wide enough to ensure no significant voltage drops to occur when the 2A current peaks are absorbed. This is a must for the same above-mentioned reasons. Try to keep this trace as short as possible.  The PCB traces connecting the Switching output to the inductor and the switching diode must be kept as short as possible by placing the inductor and the diode very close to the power switching IC (only for switching power supply). This is done in order to reduce the radiated field (noise) at the switching frequency (usually 100-500 kHz).  The use of a good common ground plane is suggested.  The placement of the power supply on the board must be done in a way to guarantee that the high current return paths in the ground plane are not
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 41 of 84  overlapped to any noise sensitive circuitry as the microphone amplifier/buffer or earphone amplifier.  The power supply input cables must be kept separately from noise sensitive lines such as microphone/earphone cables.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 42 of 84  6. Antenna(s) The antenna connection and board layout design are the most important parts in the full product design and they strongly reflect on the product’s overall performances. Read carefully and follow the requirements and the guidelines for a proper design. 6.1. GSM/WCDMA Antenna Requirements The antenna for a Telit HE920 device must fulfill the following requirements:  When using the Telit HE920, since there’s no antenna connector on the module, the antenna must  be  connected  to  the  HE920  antenna  pad  (AD1)  by  means  of  a  transmission  line implemented in the PCB. In the case that the antenna is not directly connected at the antenna pad of the HE920, then a PCB line is required in order to connect with it or with its connector.  This transmission line shall fulfill the following requirements: Antenna Line on PCB Requirements Characteristic Impedance 50Ohm Max Attenuation 0.3dB Coupling with other signals shall be avoided Cold End (Ground Plane) of antenna shall be equipotential to the HE920 ground pads GSM / WCDMA Antenna Requirements Frequency range Depending by frequency band(s) provided by the network operator, the customer must use the most suitable antenna for that/those band(s) Bandwidth HE920-EU HE920-NA GSM850 : 70 MHz GSM900 : 80 MHz GSM1800(DCS) : 170 MHz GSM1900(PCS) : 140 MHz  WCDMA band I(2100) : 250 MHz WCDMA band V(850) : 70 MHz WCDMA band VIII(900) : 80 MHz GSM850 : 70 MHz GSM900 : 80 MHz GSM1800(DCS) : 170 MHz GSM1900(PCS) : 140 MHz WCDMA band II(1900) : 140 MHz WCDMA band IV(AWS) : 445 MHz WCDMA band V(850) : 70 MHz Impedance 50 Ohm Input power > 33dBm(2 W) peak power in GSM > 24dBm Average power in WCDMA VSWR absolute max <= 5:1(limit to avoid permanent damage) VSWR recommended <= 2:1(limit to fulfill all regulatory requirements)
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 43 of 84  Furthermore if the device is developed for the US and/or Canada market, it must comply with the FCC and/or IC approval requirements: This device is to be used only for mobile and fixed application. In order to re-use the Telit FCC/IC approvals the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter. If antenna is installed with a separation distance of less than 20 cm from all persons or is co-located or operating in conjunction with any other antenna or transmitter then additional FCC/IC testing may be required. End-Users must be provided with transmitter operation conditions for satisfying RF exposure compliance.  OEM integrators must ensure that the end user has no manual instructions to remove or install the HE920 module. Antennas used for this OEM module must not exceed 6.79dBi gain for 850MHz bands, 3.01dBi gain for 1900MHz bands and 2.7dBi for 1700MHz bands for mobile and fixed operating configurations.  6.2. GSM/WCDMA Antenna – PCB line Guidelines  Make sure that the transmission line’s characteristic impedance is 50ohm.  Keep line on the PCB as short as possible since the antenna line loss shall be less than around 0.3dB.  Line  geometry  should  have  uniform  characteristics,  constant  cross  section,  avoid meanders and abrupt curves.  Any  kind  of  suitable  geometry/structure  can  be  used  for  implementing  the  printed transmission line afferent the antenna.  If a  Ground  plane is  required in  line geometry, that  plane  has to  be  continuous  and sufficiently  extended  so  the  geometry  can  be  as  similar  as  possible  to  the  related canonical model.  Keep,  if  possible,  at  least one  layer  of  the  PCB  used  only  for  the  Ground plane;  If possible, use this layer as reference Ground plane for the transmission line.  It is wise to surround (on both sides) of the PCB transmission line with Ground. Avoid having other signal tracks facing directly the antenna line track.  Avoid  crossing  any  un-shielded  transmission  line  footprint  with  other  tracks  on different layers.  The Ground surrounding the antenna line on PCB has to be strictly connected to the main Ground plane by means of via holes (once per 2mm at least) placed close to the ground edges facing line track.  Place EM noisy devices as far as possible from HE920 antenna line.  Keep the antenna line far away from the HE920 power supply lines.  If EM noisy devices are present on the PCB hosting the HE920, such as fast switching ICs, take care of shielding them with a metal frame cover.  If EM noisy devices are not present around the line use of geometries like Micro strip or  Grounded  Coplanar  Waveguide  are  preferred  since  they  typically  ensure  less attenuation when compared to a Strip line having same length.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 44 of 84  6.3. GSM/WCDMA Antenna – Installation Guidelines  Install the antenna in a place covered by the GSM/WCDMA signal.  The Antenna shall be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter;  If the device antenna is located greater then 20cm from the human body and there are no co-located transmitter then the Telit FCC/IC approvals can be re-used by the end product.  If the device antenna is located less then 20cm from the human body or there are no co-located transmitter then the additional FCC/IC testing may be required for the end product (Telit FCC/IC approvals cannot be reused)   Antenna shall not be installed inside metal cases;   Antenna shall be installed also according Antenna manufacturer instructions.  6.4. Antenna Diversity Requirements This product is including an input for a second RX antenna to improve the radio sensitivity. The function is called Antenna Diversity. ANTENNA  REQUIREMENTS Frequency range Depending by frequency band(s) provided by the network operator, the customer shall use the most suitable antenna for that/those band(s) Bandwidth HE920-EU HE920-NA WCDMA band I(2100) : 60 MHz WCDMA band V(850) : 25 MHz WCDMA band VIII(900) : 35 MHz WCDMA band II(1900) : 60 MHz WCDMA band IV(AWS) : 45 MHz WCDMA band V(850) : 25 MHz Impedance 50Ω  When using the Telit HE920, since there’s no antenna connector on the module, the antenna must  be  connected  to  the  HE920  antenna  pad  (AU9)  by  means  of  a  transmission  line implemented on the PCB.  In the case that the antenna is not directly connected at the antenna pad of the HE920, then a PCB line is required in order to connect with it or with its connector.  The second Rx antenna should not be located in the close vicinity of main antenna. In order to improve Diversity Gain, Isolation and reduce mutual interaction, the two antennas should be located at the maximum reciprocal distance possible, taking into consideration the available space into the application.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 45 of 84  NOTE:  If the RX Diversity is not used/connected, disable the Diversity functionality using the AT#CRXD command and leave the pad AU9 unconnected. Please refer to the AT command User Guide in detail.  6.5. GPS/GNSS Antenna Requirements The use of an active GPS/GNSS antenna is required to achieve better performance. The module is provided with a Digital Output signal to enable the external LNA (pad V2). Parameter Min Max Output high level 1.35V 1.8V Output low level 0V 0.45V 6.5.1. Combined GPS/GNSS Antenna The  use  of  combined  RF/GPS/GNSS  antenna  is  NOT recommended.   This  solution  could generate  extremely  poor  GPS/GNSS  reception  and  also  the  combined  antenna  requires additional diplexer and adds a loss in the RF route. In  addition,  the  combination  of  antennas  requires  an  additional  diplexer,  which  adds significant power losses in the RF path. 6.5.2. Linear and Patch GPS/GNSS Antenna Using this type of antenna introduces at least 3dB of loss if compared to a circularly polarized (CP)  antenna.  Having  a  spherical  gain  response  instead  of  a  hemispherical  gain  response could aggravate the multipath behaviour & create poor position accuracy. 6.5.3. LNA and Front End Design Considerations Depending on the characteristics and requirements unique to the customer’s designs, the use of  an  external  LNA  or  an  external  active  antenna  may  be  required  to  achieve  best performance. The optional external LNA should be dimensioned to avoid an excessive LNA gain that can introduce jamming, spurious, degrade IIP3, and saturate the receiver.  The configurations of an external device must fulfill the following requirements:  An external passive antenna (GPS only)  An external active antenna (GPS or GNSS)  An external passive antenna, GNSS pre-Filter and GNSS LNA (GPS or GNSS)
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 46 of 84  NOTE: The external GNSS LNA and GNSS pre-Filter shall be required for GLONASS application. GNSS LNA requirement shall fulfill the following specifications.  Frequency = 1565 – 1606MHz  Power Gain|S21|2 = 14 – 17dB  NF < 1dB GNSS pre-Filter requirement shall fulfill the following requirements.  Source and Load Impedance = 50Ohm  Insertion Loss (1575.42 – 1576.42MHz) = 1.4dB (Max)  Insertion Loss (1565.42 – 1585.42MHz) = 2.0dB (Max)  Insertion Loss (1597.5515 – 1605.886MHZ) = 2.0dB (Max)   WARNING: The  HE920  software  is  implemented  differently  depending  on  the  configurations  of  an external device. Please refer to the AT command User Guide in detail.  The external active antenna for the Telit HE920 device must fulfill the following requirements: ACTIVE GPS/GNSS Antenna Requirements Frequency range GNSS(GPS L1 & GLONASS) : 1565 MHz ~ 1606 MHz GPS L1 : 1575.42MHz GLONASS : 1597.55 – 1605.89MHz Bandwidth GPS L1 : +/- 1.023MHz GLONASS : 8.34MHz Impedance 50 Ohm LNA NF < 1dB LNA  Gain 14 ~ 17dB LNA Input Voltage 3.0V or 5.0V  NOTE:  The maximum DC voltage applicable to ANT_GPS pin is 5V. In case this is exceeded, a series capacitor has to be included in the design to avoid exceeding the maximum input DC level.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 47 of 84  An example of GNSS antenna supply circuit is shown in the following image:   When using the Telit HE920, since there’s no antenna connector on the module, the antenna must be connected to the HE920 through the PCB with the antenna pad.   In the case that the antenna is not directly connected at the antenna pad of the HE920, then a PCB line is required.  This line of transmission shall fulfill the following requirements: Antenna Line on PCB Requirements Characteristic Impedance 50Ohm Max Attenuation 0.3dB Coupling with other signals shall be avoided Cold End (Ground Plane) of antenna shall be equipotential to the HE920  ground pads  Furthermore if the device is developed for the US and/or Canada market, it must comply with the FCC and/or IC requirements. This device is to be used only for mobile and fixed application.   6.5.4. GPS/GNSS Antenna - PCB Line Guidelines  Ensure that the antenna line impedance is 50ohm.  Keep line on the PCB as short as possible to reduce the loss.  Antenna line must have uniform characteristics, constant cross section, avoid meanders and abrupt curves.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 48 of 84   Keep one layer of the PCB used only for the Ground plane; if possible.  Surround (on the sides, over and under) the antenna line on PCB with Ground.   Avoid having other signal tracks directly facing the antenna line track.  The Ground around the antenna line on PCB has to be strictly connected to the main Ground plane by placing vias once per 2mm at least.  Place EM noisy devices as far as possible from HE920 antenna line.  Keep the antenna line far away from the HE920 power supply lines.   If EM noisy devices are around the PCB hosting the HE920, such as fast switching ICs, take  care  of  shielding  of  antenna  line  by  burying  it  inside  the  layers  of  PCB  and surround it with Ground planes; or shield it with a metal frame cover.  If you do not have EM noisy devices around the PCB of HE920, use a strip line on the superficial copper layer for the antenna line. The line attenuation will be lower than a buried one. 6.5.5. GPS/GNSS Antenna – Installation Guidelines  The HE920, due to its sensitivity characteristics, is capable of performing a fix inside buildings. (In any case the sensitivity could be affected by the building characteristics i.e. shielding)  The Antenna must not be co-located or operating in conjunction with any other antenna or transmitter.  Antenna shall not be installed inside metal cases.  Antenna shall be installed also according antenna manufacture instructions.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 49 of 84  7. Logic Level Specifications Where not specifically stated, all the interface circuits work at 1.8V CMOS logic levels. The following table shows the logic level specifications used in the Telit HE920 interface circuits:  NOTE:  Do not connect HE920’s digital logic signal directly to OEM’s digital logic signal of with level higher than 2.7V for 1.8V CMOS signals.   For 1,8V CMOS signals:  Absolute Maximum Ratings -Not Functional Parameter HE920 Min Max Input level on any digital pin when on -0.3V +2.7V Input voltage on analog pins when on -0.3V +2.7 V   Operating Range - Interface levels (1.8V CMOS) Level HE920 Min Max Input high level 1.5V 2.1V Input low level -0.3V 0.5V Output high level 1.35V 1.8V Output low level 0V 0.45V
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 50 of 84  7.1. Reset Signal(Module Restart)  Signal Function I/O PAD Number RESET* Phone reset (restart) I AP1  RESET is used to reset the HE920 module. Whenever this signal is pulled low HE920 is reset (restart). When the device is reset it stops all operations. After the release of the reset HE920 is unconditionally shut down, without doing any detach operations from the network where it is registered. This behavior is not a proper shutdown because the device is requested to issue a detach request on turn off. For this reason, the Reset signal must not be used for normally shutting down the device, but only as an emergency exit in the rare case the device remains stuck waiting for some network response. The RESET is internally controlled on start-up to achieve always a proper power-on reset sequence. There is no need to control this pin on start-up. It may only be used to reset a device already on that is, not responding to any command. NOTE:  Do not use this signal to power off HE920. Use the ON/OFF signal to perform this function or the AT#SHDN command.  Reset Signal Operating levels: Signal Min Max RESET Input high 1.5V* 2.1V RESET Input low 0V 0.2V * This signal is internally pulled up so the pin can be left floating if not used. If unused, this signal may be left unconnected. If used, it must always be connected with an open collector transistor to permit the internal circuitry the power on reset and under voltage lockout functions.  NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 51 of 84  8. USB Port The HE920 module includes a Universal Serial Bus (USB) transceiver, which operates at USB low-speed (1.5Mbits/sec), USB full-speed (12Mbits/sec) and USB high-speed (480Mbits/sec). It is compliant with the USB 2.0 specification and can be used for diagnostic monitoring, control and data transfers.  The  USB_DPLUS  and  USB_DMINUS  signals  have  a  clock  rate  of  480MHz.  The  signal traces should be routed carefully. Trace lengths, number of vias and capacitive loading should be minimized. The impedance value should be as close as possible to 90 Ohms differential.  The table below describes the USB interface signals:   TIP:  HE920 does NOT support host device operation at the moment, that is, it works as a slave device. Consequently USB_ID must be opened (not connected).   Pad No. Signal I/O Function Type NOTE A18 USB_VBUS AI Power sense for the internal USB transceiver. 5V  F19 USB_D- I/O USB differential Data (-)   D19 USB D+ I/O USB differential Data (+)   B19 USB_ID (for future use)
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 52 of 84  9. Serial Ports The serial port on the Telit HE920 is the interface between the module and OEM hardware.  2 serial ports are available on the module:  MODEM SERIAL PORT 1(Main)  MODEM SERIAL PORT 2 (Auxiliary)  Several configurations can be designed for the serial port on the OEM hardware.  The most common are:  RS232 PC com port;  microcontroller UART @ 1.8V (Universal Asynchronous Receive Transmit) ;  microcontroller UART @ 5V or other voltages different from 1.8V.  Depending on the type of serial port on the OEM hardware, a level translator circuit may be needed to make the system work. The only configuration that does not need a level translation is the 1.8V UART. The serial port 1 on HE920 is a +1.8V UART with all the 7 RS232 signals. It differs from the PC-RS232 in signal polarity (RS232 is reversed) and levels. The Serial port 2 is a +1.8V Auxiliary UART. The levels for HE920 UART are the CMOS levels:  Absolute Maximum Ratings -Not Functional Parameter HE920 Min Max Input level on any digital pin when on -0.3V +2.7V Input voltage on analog pins when on -0.3V +2.7 V   Operating Range - Interface levels Level HE920 Min Max Input high level 1.5V 2.1V Input low level -0.3V 0.5V Output high level 1.35V 1.8V Output low level 0V 0.45V
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 53 of 84  9.1. Modem Serial Port 1 Serial port 1 on the HE920 is a +1.8V UART with all 7 RS232 signals. It differs from the PC-RS232 in the signal polarity (RS232 is reversed) and levels.  RS232 Pin Number Signal HE920  Pad Number Name Usage 1 DCD - dcd_uart AE18 Data Carrier Detect Output from the HE920 that indicates the carrier presence 2 RXD - Tx_uart AF19 Transmit line *see Note Output transmit line of the HE920 UART 3 TXD - Rx_uart AH19 Receive line  *see Note Input receive of the HE920 UART 4 DTR - dtr_uart AC18 Data Terminal Ready Input to the HE920 that controls the DTE READY condition 5 GND A6, A12, B13, B15…. Ground ground 6 DSR - dsr_uart AG18 Data Set Ready Output from the HE920 that indicates the module is ready 7 RTS -rts_uart AA18 Request to Send Input to the HE920 that controls the Hardware flow control 8 CTS - cts_uart AK19 Clear to Send Output from the HE920 that controls the Hardware flow control 9 RI - ri_uart AJ18 Ring Indicator Output from the HE920 that indicates the Incoming call condition   NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.  TIP:  For minimum implementation, only the TXD and RXD lines can be connected, the other lines can be left open provided a software flow control is implemented. NOTE:  According to V.24, RX/TX signal names are referred to the application side, therefore on the HE920 side these signal are on the opposite direction: TXD on the application side will be connected to the receive line (here named TXD/ rx_uart ) of the HE920 serial port and vice versa for RX.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 54 of 84  9.2. Modem Serial Port 2 Serial port 2 on the HE920 is a +1.8V UART with only the RX and TX signals.  The signals of the HE920 serial port are: PAD Signal I/O Function Type COMMENT AB19 TXD_AUX O Auxiliary UART (TX Data to DTE) 1.8V  AD19 RXD_AUX I Auxiliary UART (RX Data to DTE) 1.8V   NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.  9.3. RS232 Level Translation In order to interface the Telit HE920 with a PC com port or a RS232 (EIA/TIA-232) application a level translator is required. This level translator must:  invert the electrical signal in both directions;  Change the level from 0/1.8V to +15/-15V. Actually, the RS232 UART 16450, 16550, 16650 & 16750 chipsets accept signals with lower levels on the RS232 side (EIA/TIA-562), allowing a lower voltage-multiplying ratio on the level translator. Note that the negative signal voltage must be less than 0V and hence some sort of level translation is always required.  The simplest way to translate the levels and invert the signal is by using a single chip level translator. There are a multitude of them, differing in the number of drivers and receivers and in the levels (be sure to get a true RS232 level translator not a RS485 or other standards). By convention the driver is the level translator from the 0-1.8V UART to the RS232 level. The receiver is the translator from the RS232 level to 0-1.8V UART. In order to translate the whole set of control lines of the UART you will need:  5 drivers  3 receivers NOTE:  The digital input lines working at 1.8V CMOS have an absolute maximum input voltage of 2.7V; therefore the level translator IC shall not be powered by the +3.8V supply of the module. Instead, it must be powered from a +1.8V (dedicated) power supply. This is because in this way the level translator IC outputs on the module side (i.e. HE920 inputs) will work at +3.8V interface levels, damaging the module inputs.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 55 of 84  An  example  of  RS232  level  adaption  circuitry  could  be  accomplished  using  a  MAXIM transceiver (MAX218).  In  this  case  the  chipset  is  capable  of  translating  directly  from  1.8V  to  the  RS232  levels (Example on 4 signals only).    NOTE:  In this case has to be taken in account the length of the lines on the application to avoid problems in case of High-speed rates on RS232.  The RS232 serial port lines are usually connected to a DB9 connector with the following layout: signal names and directions are named and defined from the DTE point of view
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 56 of 84  10. Audio Section Overview The HE920 module supports an analog audio interface and digital audio interface.   10.1. Analog Audio The HE920 module provides two analog audio paths transmitting and receiving. Please refer to the xE920_Audio_Settings_Application_Note, 80404NT10095A   10.2. Digital Audio HE920 module can be connected to external codec through digital interface. The product is providing one Digital Audio Interface (DVI) on the following Pins: PAD Signal I/O Function Type COMMENT D11 DVI_WA0 I/O Digital Audio Interface (WA0) B-PD 1.8V  C8 DVI_RX I Digital Audio Interface (RX) B-PD 1.8V  D9 DVI_TX O Digital Audio Interface (TX) B-PD 1.8V  C10 DVI_CLK I/O Digital Audio Interface (CLK) B-PD 1.8V   10.2.1. CODEC Example Please refer to the Telit_UE_HE910V2_DE_CE910_HE920_DVI_Application_Note.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 57 of 84  11. General Purpose I/O The general-purpose I/O pads can be configured to act in three different ways:  input  output  alternate function (internally controlled) Input pads can only be read and report the digital value (high or low) present on the pad at the read time; output pads can only be written or queried and set the value of the pad output; an alternate function pad is internally controlled by the HE920 firmware and acts depending on the function implemented.  The following GPIOs are available on the HE920. PAD Signal I/O Function Type Drive Strength F9 GPIO_01 I/O Configurable GPIO B-PD 1.8V 2 mA E10 GPIO_02 I/O Configurable GPIO B-PD 1.8V 2 mA F11 GPIO_03 I/O Configurable GPIO B-PD 1.8V 2 mA E12 GPIO_04 I/O Configurable GPIO B-PD 1.8V 2 mA F13 GPIO_05 I/O Configurable GPIO B-PD 1.8V 2 mA E14 GPIO_06 I/O Configurable GPIO B-PD 1.8V 2 mA R18 GPIO_07 I/O Configurable GPIO B-PD 1.8V 2 mA S19 GPIO_08 I/O Configurable GPIO B-PD 1.8V 2 mA U19 GPIO_09 I/O Configurable GPIO B-PD 1.8V 2 mA W19 GPIO_10 I/O Configurable GPIO B-PD 1.8V 2 mA  NOTE:  In order to avoid a back powering effect it is recommended to avoid having any HIGH logic level signal applied to the digital pins of the module when is powered OFF or during an ON/OFF transition.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 58 of 84   11.1. Logic Level Specifications Where not specifically stated, all the interface circuits work at 1.8V CMOS logic levels. The following table shows the logic level specifications used in the HE920 interface circuits:  For 1,8V signals: Absolute Maximum Ratings -Not Functional Parameter HE920 Min Max Input level on any digital pin when on -0.3V +2.7V Input voltage on analog pins when on -0.3V +2.7 V  Operating Range - Interface levels (1.8V CMOS) Level HE920 Min Max Input high level 1.5V 2.1V Input low level -0.3V 0.5V Output high level 1.35V 1.8V Output low level 0V 0.45V    11.2. Using a GPIO Pad as Input The GPIO pads, when used as inputs, can be connected to a digital output of another device and report its status, provided this device has interface levels compatible with the 1.8V CMOS levels of the GPIO.  If the digital output of the device is connected with the GPIO input, the pad has interface levels different from the 1.8V CMOS. It can be buffered with an open collector transistor with a 47KΩ pull-up resistor to 1.8V.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 59 of 84   11.3. Using a GPIO Pad as Output The GPIO pads, when used as outputs, can drive 1.8V CMOS digital devices or compatible hardware. When set as outputs, the pads have a push-pull output and therefore the pull-up resistor may be omitted.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 60 of 84   11.4. Using the Temperature Monitor Function 11.4.1. Short Description The Temperature Monitor is a function of the module that permits to control its internal temperature and if properly set (see the #TEMPMON command on AT Interface guide) it raises to High Logic level a GPIO when the maximum temperature is reached.   11.5. Indication of Network Service Availability The STAT_LED pin status shows information on the network service availability and Call status. In the HE920 modules, the STAT_LED usually needs an external transistor to drive an external LED. Because of the above, the status indicated in the following table is reversed with respect to the pin status:  LED status Device Status Permanently off Device off Fast blinking (Period 1s, Ton 0,5s) Net search / Not registered / turning off Slow blinking (Period 3s, Ton 0,3s) Registered full service Permanently on a call is active
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 61 of 84  11.6. RTC Bypass Out The VRTC pin brings out the Real Time Clock supply, which is separate from the rest of the digital part, allowing having only RTC going on when all the other parts of the device are off. To this power output a backup capacitor can be added in order to increase the RTC autonomy during power off of the battery.   NOTE:  NO devices must be powered from this pin.   11.7. VAUX Power Output A regulated power supply output is provided in order to supply small devices from the module. This output is active when the module is ON and goes OFF when the module is shut down. The operating range characteristics of the supply are: Operating Range – VAUX power supply  Min Typical Max Output voltage 1.75V 1.80V 1.85V Output current   100mA Output bypass capacitor (Inside the module)   2.2μF
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 62 of 84  12. DAC and ADC section 12.1. DAC Converter 12.1.1. Description The HE920 module provides a Digital to Analog Converter. The signal (named DAC_OUT) is available on pad E14 of the HE920 module. The on board DAC is in the range from 0 to 1023.  However, an external low-pass filter is necessary.   Min Max Units Voltage range (filtered) 0 1.8 Volt Range 0 1023 Steps  The precision is 1023 steps, so if we consider that the maximum voltage is 1.8V, the integrated voltage could be calculated with the following formula: Integrated output voltage = 1.8 * value / 1023 DAC_OUT line must be integrated (for example with a low band pass filter) in order to obtain an analog voltage.  12.1.2. Enabling DAC An AT command is available to use the DAC function.  The command is:AT#DAC[=<enable>[,<value>]] <value> - scale factor of the integrated output voltage (0..1023 - 10 bit precision) it must be present if <enable>=1 Refer to SW User Guide or AT Commands Reference Guide for the full description of this function.  NOTE:  The DAC frequency is selected internally. D/A converter must not be used during POWERSAVING.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 63 of 84  12.1.3. Low Pass Filter Example .  12.2. ADC Converter 12.2.1. Description The on board ADCs are 8-bit converters. They are able to read a voltage level in the range of 0-2 volts applied on the ADC pin input and store and convert it into 8 bit word.   Min Max Units Input Voltage range 0 2.0 Volt AD conversion - 8 bits Resolution - <  8.6 mV  The HE920 module provides 2 Analog to Digital Converters.   12.2.2. Using ADC Converter An AT command is available to use the ADC function.  The command is AT#ADC=1,2. The read value is expressed in mV Refer to SW User Guide or AT Commands Reference Guide for the full description of this function.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 64 of 84  13. Mounting the module on your board 13.1. General The HE920 modules have been designed in order to be compliant with a standard lead-free SMT process.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 65 of 84  13.2. Module Finishing & Dimensions
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 66 of 84  13.3. Recommended foot print for the application   198 pads Top View  In order to easily rework the HE920 it is suggested to consider on the application having a 1.5 mm placement inhibit area around the module.  It is also suggested, as a common rule for an SMT component, to avoid having a mechanical part of the application in direct contact with the module.  NOTE: In the customer application, the region under WIRING INHIBIT (see figure above) must be clear from signal or ground paths.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 67 of 84  13.4. Stencil Stencil’s apertures layout can be the same as the recommended footprint (1:1), we suggest a thickness of stencil foil ≥ 120 µm.   13.5. PCB Pad Design Non solder mask defined (NSMD) type is recommended for the solder pads on the PCB.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 68 of 84   13.6. Recommendations for PCB Pad Dimensions (mm) The recommendation for the PCB pads dimensions are described in the following image (dimensions in mm)
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 69 of 84  It is not recommended to place via or micro-via not covered by solder resist in an  area of  0,3 mm around the pads unless it carries the same signal of the pad itself  (see following figure).    Holes in pad are allowed only for blind holes and not for through holes.  Recommendations for PCB Pad Surfaces: Finish Layer thickness (um) Properties Electro-less Ni / Immersion Au 3 –7 / 0.05 – 0.15 good solder ability protection, high shear force values  The PCB must be able to resist the higher temperatures which are occurring at the lead-free process. This issue should be discussed with the PCB-supplier. Generally, the wettability of tin-lead solder paste on the described surface plating is better compared to lead-free solder paste.  It is not necessary to panel the application’s PCB, however in that case it is suggested to use milled  contours  and  predrilled  board  breakouts;  scoring  or  v-cut  solutions  are  not recommended.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 70 of 84  13.7. Solder Paste  Lead free Solder Paste Sn/Ag/Cu  We  recommend  using  only  “no  clean”  solder  paste  in  order  to  avoid  the  cleaning  of  the modules after assembly.   13.7.1. Solder Reflow  Recommended solder reflow profile:
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 71 of 84   Profile Feature Pb-Free Assembly Average ramp-up rate(TL to Tp) 3℃/second max Preheat - Temperature Min(Tsmin) - Temperature Max(Tsmax) - Time (min to max) (ts)  150℃ 200℃ 60 - 180 seconds Tsmax to TL - Ramp-up Rate  3℃/second max Time maintained above: - Temperature (TL) - Time(tL)  217℃ 60 - 150 seconds Peak Temperature (Tp) 245 +0/-5℃ Time within 5℃ of actual Peak Temperature(tp) 10 - 30 seconds   Ramp-down Rate 6℃/sec max Time 25℃ to Peak Temperature 8 minutes max  NOTE: All temperatures refer to topside of the package, measured on the package body surface.  WARNIG: The HE920 module withstands one reflow process only.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 72 of 84  14. Application guide 14.1. Debug of the HE920 in production To test and debug the mounting of HE920, we strongly recommend foreseeing test pads on the host PCB, in order to check the connection between the HE920 itself and the application and to test the performance of the module connecting it with an external computer. Depending on the customer application, these pads include, but are not limited to the following signals:   TXD  RXD  ON/OFF  RESET  GND  VBATT  TX_TRACE  RX_TRACE  PWRMON   USB_VBUS  USB_D+  USB_D-
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 73 of 84  14.2. Bypass capacitor on Power supplies When a sudden voltage is asserted to or cut from the power supplies, The steep transition makes some reactions such as the overshoot and undershoot. This abrupt voltage transition can affect the device not to work or make it malfunction. The bypass capacitors are needed to alleviate this behavior and it can be affected differently according to the various applications. The customers have to pay special attention to this when they design their application board.. The length and width of the power lines need to be considered carefully and the capacitance of the capacitors need to be selected accordingly. The capacitor will also avoid the ripple of the power supplies and the switching noise caused in TDMA system like GSM.  Specially the suitable bypass capacitor must be mounted on the VBATT and VBATT_PA  lines in the application board.  The recommended values can be presented as;   100uF for VBATT and VBATT_PA  But the customers still have to consider that the capacitance mainly depends on the  conditions of their application board. Generally more capacitance is required as the power line is longer.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 74 of 84  14.3. SIM interface This section deals with the recommended schematics for the design of SIM interfaces on the application boards. 14.3.1. SIM schematic example Figure 1 illustrates in particular how the application side should be designed, and what values the components should have.   NOTE FOR R1: The resistor value on SIMIO pulled up to SIMVCC should be defined accordingly in order to be compliant to 3GPP specification. For HE920-EU and HE920-NA contain an internal pull-up resistor on SIMIO. However, the un-mounted option in application design can be recommended in order to tune R1 if necessary.   The following Table lists the values of C1 to be adopted with the HE920 product:  Product P/N C1 range (nF) HE920-EU 100 nF HE920-NA  Refer to the following document for the detail;   Telit_SIM_Integration_Design_Guide_Application_Note
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 75 of 84  14.4. EMC recommendations HE920 signals are provided by some EMC protections. In any case the accepted levels are different on the pins. The characteristics are described in the following Table:  Pad Signal I/O Function Contact Air Power Supply AP17,AP19,AR18,AS17,AS19,AT18,AU17,AU19 VBATT_PA And VBATT - Main power supply ± 8KV ± 15KV SIM Card Interface A8 SIMVCC - External SIM signal – Power supply for the SIM ± 8KV ± 15KV B11 SIMRST O External SIM signal – Reset ± 8KV ± 15KV B9 SIMIO I/O External SIM signal - Data I/O ± 8KV ± 15KV A10 SIMCLK O External SIM signal – Clock ± 8KV ± 15KV Miscellaneous Functions P17 VAUX - Power output for external accessories ± 8KV ± 15KV AS1 ON/OFF I Input command for switching power ON or  OFF (toggle command).  ± 8KV ± 15KV AP1 RESET I Reset input ± 8KV ± 15KV F17 VRTC AO Power supply for RTC block ± 8KV ± 15KV Antenna AD1,AU9,S1 Antenna Pad AI Antenna pad ± 8KV ± 15KV  All other pins have the following characteristics:  HBM JESD22-A114-B ± 2000 V CDM JESD22-C101-C ± 500 V  Appropriate series resistors have to be considered to protect the input lines from overvoltage.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 76 of 84  14.5. Download and Debug Port One  of  the  following  options  should  be  chosen  in  the  design  of  host  system  in  order  to download or upgrade the Telit’s software and debug HE920 when HE920 is already mounted on a host system.  Users who use both of UART and USB interfaces to communicate HE920 -  Must  implement  a  download  method  in  a  host  system  for  upgrading  HE920  when  it’s mounted.  Users who use USB interface only to communicate HE920 -  Must arrange UART port in a host system for debugging or upgrading HE920 when it’s mounted.  Users who use UART interface only to communicate HE920 -  Must arrange  USB port  in a  host system for  debugging or  upgrading  HE920  when  it’s mounted.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 77 of 84  15. Packing system The Telit HE920 is packaged on trays. Each tray contains 20 pieces with the following dimensions:  15.1. Tray Drawing   (1VV0700623_DTS)  WARNIG: These trays can withstand a maximum temperature of 65℃.   15.2. Moisture Sensibility The HE920 is a Moisture Sensitive Device level 3, in accordance with standard IPC/JEDEC J-STD-020, take care all the relatives requirements for using this kind of components. Moreover, the customer has to take care of the following conditions: a) Calculated shelf life in sealed bag: 12 months at <40°C and <90% relative humidity (RH). b) Environmental condition during the production: 30°C / 60% RH according to IPC/JEDEC J-STD-033A paragraph 5.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 78 of 84  c) The maximum time between the opening of the sealed bag and the reflow process must be 168 hours if condition b) “IPC/JEDEC J-STD-033A paragraph 5.2” is respected  d) Baking is required if conditions b) or c) are not respected  e) Baking is required if the humidity indicator inside the bag indicates 10% RH or more
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 79 of 84  16. Conformity Assessment Issues 16.1. 1999/5/EC Directive  The HE920-EU module has been assessed in order to satisfy the essential requirements of the R&TTE Directive 1999/05/EC (Radio Equipment & Telecommunications Terminal Equipments) to demonstrate the conformity against the harmonized standards with the final involvement of a Notified Body.  In order to satisfy the essential requirements of 1999/5/EC Directive, the HE920-EU is compliant with the following standards:  RF spectrum use (R&TTE art. 3.2) EN 300 440-2 V1.4.1 EN 301 511 V9.0.2 EN 301 908-1 V5.2.1 EN 301 908-2 V5.2.1 EMC (R&TTE art. 3.1b) EN 301 489-1 V1.9.2 EN 301 489-3 V1.4.1  EN 301 489-7 V1.3.1 EN 301 489-24 V1.5.1 Health & Safety (R&TTE art. 3.1a) EN 60950-1:2006 + A11:2009 + A1:2010 + A12:2011+AC:2011  The conformity assessment procedure referred to in Article 10 and detailed in Annex IV of Directive 1999/5/EC has been followed with the involvement of the following Notified Body:   AT4 wireless, S.A. Parque Tecnologico de Andalucía C/ Severo Ochoa 2 29590 Campanillas – Málaga SPAIN Notified Body No: 1909  Thus, the following marking is included in the product:    The full declaration of conformity can be found on the following address:  http://www.telit.com  There is no restriction for the commercialization of the HE920-EU module in all the countries of the European Union.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 80 of 84  Final product integrating this module must be assessed against essential requirements of the 1999/5/EC (R&TTE) Directive. It should be noted that assessment does not necessarily lead to testing. Telit Communications S.p.A. recommends carrying out the following assessments:  RF spectrum use (R&TTE art. 3.2) It will depend on the antenna used on the final product. EMC (R&TTE art. 3.1b) Testing Health & Safety (R&TTE art. 3.1a) Testing  Alternately, assessment of the final product against EMC (Art. 3.1b) and Electrical safety (Art. 3.1a) essential requirements can be done against the essential requirements of the EMC and the LVD Directives:   Low Voltage Directive 2006/95/EC and product safety   Directive EMC 2004/108/EC for conformity for EMC
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 81 of 84  16.2. FCC/IC Regulatory notices  Modification statement  Telit has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment.  Telit n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur.  Interference statement  This device complies with Part 15 of the FCC Rules and Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. This Class B digital apparatus complies with Canadian ICES-0003.  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Wireless notice  This equipment complies with FCC and IC radiation exposure limits set forth for an uncontrolled environment. The antenna should be installed and operated with minimum distance of 20 cm between the radiator and your body. Antenna gain must be below:  Frequency band HE920-NA GSM850 / FDD V 6.79 dBi PCS1900 / FDD II 3.01 dBi FDD IV 2.7 dBi  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Cet appareil est conforme aux limites d'exposition aux rayonnements de la IC pour un environnement non contrôlé. L'antenne doit être installé de façon à garder une distance minimale de 20 centimètres entre la source de rayonnements et votre corps. Gain de l'antenne doit être ci-dessous:  Bande de fréquence HE920-NA GSM850 / FDD V 6.79 dBi PCS1900 / FDD II 3.01 dBi FDD IV 2.7 dBi  L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec à autre antenne ou autre émetteur.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 82 of 84   FCC Class B digital device notice  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:   - Reorient or relocate the receiving antenna.  - Increase the separation between the equipment and receiver.  - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  - Consult the dealer or an experienced radio/TV technician for help.   Information To Be Supplied to the End User by the OEM or Integrator notice  Modular information form OEM Information to Be Supplied to the End User by the OEM or Integrator  The following regulatory and safety notices must be published in documentation supplied to the end user of the product or system incorporating an adapter in compliance with local regulations. Host system must be labeled with "Contains IC: 5131A-HE920NA " or "Contains FCCID:RI7HE920NA ", FCC ID/IC displayed on label.
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 83 of 84  17. Safety Recommendations READ CAREFULLY  Be sure about that the use of this product is allowed in your country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas:  Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, etc.  Where there is risk of explosion such as gasoline stations, oil refineries, etc.  It is responsibility of the user to enforce the country regulation and the specific environment regulation. Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the final product; therefore, care has to be taken to the external components of the module, as well as of any project or installation issue, because the risk of disturbing the GSM network or external devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force. Every module has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to be installed with the guarantee of a minimum 20 cm distance from the body. In case of this requirement cannot be satisfied, the system integrator has to assess the final product against the SAR regulation. The European Community provides some Directives for the electronic equipments introduced on the market. All the relevant information are available on the European Community website: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm The text of the Directive 99/05 regarding telecommunication equipments is available, while the applicable Directives (Low Voltage and EMC) are available at: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm
    HE920 Hardware User Guide 1vv0301014 Rev.9 – 2014-01-23 Reproduction forbidden without written authorization from Telit Communications S.p.A. - All Rights Reserved.    Page 84 of 84  18. Document History  Revision Date Changes 0 2012-02-02 First issue  1 2012-06-04 Renumbered chapters Updated  2.3 Weight Updated  3 HE920 Module Connections Updated 5.1 Power Supply Requirements Updated 6.5 GPS/GNSS Antenna Requirements Updated 9.2 Modem Serial Port 2 Updated 13.2 ADC Converter Updated 14.2 Module Finishing & Dimensions 2 2012-10-24 Updated 4 Hardware Commands Added 4.5 Hardware Unconditional Shutdown (Power Off) Updated 5.1 Power Supply Requirements Updated 5.2.2 Thermal Design Guidelines Updated 6.1 GSM/WCDMA Antenna Requirements Updated 7.1 Reset Signal Updated 8 USB Port Updated 13.2 Module Finishing & Dimensions Updated 14.2 Bypass capacitor on Power supplies Updated 14.4 EMC recommendations Updated 15.2 Moisture Sensibility 3 2012-11-14 Updated 5.1 Power Supply Requirements Updated 6.1 GSM/WCDMA Antenna Requirements 4 2013-01-02 Updated 5.1 Power Supply Requirements Updated 6 Antenna(s) 5 2013-03-21 Updated 6.1 GSM/WCDMA Antenna Requirements Added 16.1 1999/5/EC Directive Added 16.2 FCC/IC Regulatory notices 6 2013-05-14 Updated 1.6 Related Documents Updated 10.1 Analog Audio Updated 13.4 Stencil Updated 13.5 PCB Pad Design Updated 13.6 Recommendations for PCB Pad Dimensions (mm) Updated 13.7.1 Solder Reflow Updated 15.1 Tray Drawing 7 2013-11-08 Updated 6.5.3 LNA and Front End Design Considerations Updated 13.2 Module Finishing & Dimensions Updated 14.3 SIM Interface 8 2013-11-13 Updated 13.3 Recommended foot print for the application 9 2014-01-23 Updated 2.4.2 RoHS compliance Updated 6.1 GSM/WCDMA Antenna Requirements Updated  8 USB Port Updated 12.1 DAC Converter Updated 16.2 FCC/IC Regulatory notices

Navigation menu