Telit Communications S p A TRIZIUM Tri-band GSM/GPRS PCS Data Terminal Module User Manual 80264ST10007a r3

Telit Communications S.p.A. Tri-band GSM/GPRS PCS Data Terminal Module 80264ST10007a r3

Users Manual

Download: Telit Communications S p A TRIZIUM Tri-band GSM/GPRS PCS Data Terminal Module User Manual 80264ST10007a r3
Mirror Download [FCC.gov]Telit Communications S p A TRIZIUM Tri-band GSM/GPRS PCS Data Terminal Module User Manual 80264ST10007a r3
Document ID530579
Application IDBpTWjOdcE9PuASqRqV6cbw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize101.57kB (1269657 bits)
Date Submitted2005-04-11 00:00:00
Date Available2005-04-11 00:00:00
Creation Date2004-09-09 11:06:26
Producing SoftwareAcrobat PDFWriter 5.0 for Windows NT
Document Lastmod2005-04-11 13:01:38
Document Title80264ST10007a_r3.doc
Document CreatorMicrosoft Word - 80264ST10007a_r3.doc
Document Author: DanieleLu

Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
T el i t

TRIZIUM
Product Description
DAI Telecom S.p.a. 2003 - 2004
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 1 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Contents
OVERVIEW.................................................................................................................. 9
GENERAL PRODUCT DESCRIPTION ..................................................................... 11
2.1
Dimensions.......................................................................................................................................................11
2.2
Weight ..............................................................................................................................................................12
2.3
Environmental requirements .........................................................................................................................12
2.3.1
Temperature range ....................................................................................................................................12
2.3.2
Vibration Test (non functional).................................................................................................................12
2.4
Operating Frequency......................................................................................................................................13
2.5
Transmitter output power..............................................................................................................................13
2.6
Reference sensitivity .......................................................................................................................................13
2.7
Antenna............................................................................................................................................................13
2.7.1
Antenna connector ....................................................................................................................................14
2.8
Supply voltage .................................................................................................................................................14
2.9
Power consumption.........................................................................................................................................14
2.10
Embodied Battery charger.............................................................................................................................14
2.11
User Interface ..................................................................................................................................................14
2.11.1
Speech Coding ..........................................................................................................................................14
2.11.2
Sim Reader................................................................................................................................................15
2.11.3
SMS ..........................................................................................................................................................15
2.11.4
Real Time Clock and Alarm .....................................................................................................................15
2.11.5
Data/fax transmission................................................................................................................................15
2.11.6
Local security management.......................................................................................................................15
2.11.7
Call control................................................................................................................................................15
2.11.8
Phonebook.................................................................................................................................................15
2.11.9
Characters management ............................................................................................................................15
2.11.10
SIM related functions............................................................................................................................15
2.11.11
Call status indication.............................................................................................................................15
2.11.12
Indication of network service availability .............................................................................................16
2.11.13
Automatic answer (Voice, Data or FAX)..............................................................................................16
2.11.14
Supplementary services (SS).................................................................................................................16
2.11.15
Acoustic signaling.................................................................................................................................16
2.11.16
DTMF tones ..........................................................................................................................................16
2.11.17
Buzzer output ........................................................................................................................................17
2.12
Logic level specifications ................................................................................................................................17
2.12.1
Reset signal ...............................................................................................................................................18
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 2 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.13
RTC Bypass out...............................................................................................................................................19
2.14
Vout power output ..........................................................................................................................................19
2.15
Audio levels specifications ..............................................................................................................................20
2.16
Interfaces on TRIZIUM .................................................................................................................................21
2.17
Mounting the TRIZIUM on your Board.......................................................................................................23
2.17.1
General......................................................................................................................................................23
2.17.2
Module finishing & dimensions................................................................................................................23
2.17.3
Recommended foot print for application ..................................................................................................24
2.17.4
Stencil .......................................................................................................................................................24
2.17.5
Solder reflow.............................................................................................................................................25
2.17.6
Packing system..........................................................................................................................................26
2.17.7
Moisture sensibility...................................................................................................................................28
EVALUATION KIT ..................................................................................................... 29
3.1
Evaluation Kit description .............................................................................................................................30
3.1.1
Power Supply ............................................................................................................................................30
3.1.2
Serial interface ..........................................................................................................................................30
3.1.3
Audio ........................................................................................................................................................31
3.1.4
GPIO and Leds..........................................................................................................................................31
4.1
5.1
SERVICE AND FIRMWARE UPDATE ...................................................................... 32
Step-by-Step upgrade procedure ...................................................................................................................32
AT COMMAND .......................................................................................................... 33
Definitions........................................................................................................................................................33
5.2
AT Command Syntax .....................................................................................................................................33
5.2.1
Command lines .........................................................................................................................................33
5.2.2
Information responses and result codes ....................................................................................................35
5.2.3
Command Response Timeout ...................................................................................................................35
5.2.4
Command issuing timing ..........................................................................................................................37
5.2.5
Factory Profile and parameters stored in the profile .................................................................................37
5.3
Hayes Compliant AT Commands ..................................................................................................................38
5.3.1
Generic Modem Control ...........................................................................................................................38
5.3.1.1
&F - restore factory configuration ........................................................................................................38
5.3.1.2
Z - soft reset ..........................................................................................................................................38
5.3.1.3
+FCLASS - select active service class ..................................................................................................39
5.3.1.4
&Y - designate a default reset profile ...................................................................................................39
5.3.1.5
&W - store current configuration..........................................................................................................39
5.3.1.6
&Z - store telephone number in the Telit TRIZIUM module internal phonebook......................................40
5.3.1.7
&N - display internal phonebook stored numbers.................................................................................41
5.3.1.8
+GMI - request manufacturer identification .........................................................................................41
5.3.1.9
+GMM - request model identification ..................................................................................................41
5.3.1.10
+GMR - request revision identification.............................................................................................41
5.3.1.11
+GCAP - request capabilities list ......................................................................................................41
5.3.1.12
+GSN - request serial number...........................................................................................................42
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 3 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.13
5.3.1.14
5.3.1.15
5.3.1.16
5.3.1.17
5.3.1.18
5.3.1.19
5.3.2
5.3.2.1
5.3.2.2
5.3.2.3
5.3.2.4
5.3.2.5
5.3.2.6
5.3.2.7
5.3.2.8
5.3.2.9
5.3.2.10
5.3.2.11
5.3.2.12
5.3.2.13
5.3.2.14
5.3.3
5.3.3.1
5.3.3.2
5.3.3.3
5.3.3.4
5.3.3.5
5.3.3.6
5.3.3.7
5.3.3.8
5.3.3.9
5.3.4
5.3.4.1
5.3.4.2
5.3.5
5.3.5.1
5.3.5.2
5.3.6
5.3.6.1
5.3.6.2
5.3.7
5.3.7.1
5.3.7.2
5.3.7.3
5.3.7.4
5.3.7.5
5.3.7.6
5.3.7.7
5.3.7.8
5.3.7.9
5.3.7.10
5.3.7.11
5.3.7.12
&V - display current configuration & profile....................................................................................43
&V0 - display current configuration & profile..................................................................................43
&V1 - display S registers values .......................................................................................................43
&V2 - display last connection statistics ............................................................................................45
\V - single line connect message .......................................................................................................45
%L - report line signal level..............................................................................................................46
%Q - report line quality.....................................................................................................................46
DTE - modem interface control ................................................................................................................47
E - command echo.................................................................................................................................47
Q - quiet resut codes..............................................................................................................................47
V- result code form ...............................................................................................................................48
X - extended result codes ......................................................................................................................48
I - Request identifier and software checksum .......................................................................................49
&C - data carrier detect (DCD) control.................................................................................................49
&D - data terminal ready (DTR) control...............................................................................................50
&K - flow control..................................................................................................................................50
&S - data set ready (DSR) control ........................................................................................................50
\R - ring (RI) control .........................................................................................................................52
+IPR - fixed DTE interface rate ........................................................................................................52
+IFC - DTE - DTA flow control .......................................................................................................52
+ILRR - DTE - modem rate reporting ..............................................................................................54
+ICF - DTE - modem character format.............................................................................................55
Call Control...............................................................................................................................................56
D - dial ..................................................................................................................................................56
T - set tone dial......................................................................................................................................58
P - set pulse dial ....................................................................................................................................58
A - answer .............................................................................................................................................58
A/ - Last command automatic repetition...............................................................................................58
H - disconnect .......................................................................................................................................59
O - return to On Line Mode ..................................................................................................................60
&G - guard tone ....................................................................................................................................60
&P - pulse dial make/break ratio...........................................................................................................61
Modulation control....................................................................................................................................61
+MS - modulation control.....................................................................................................................61
%E - enable/disable line quality monitor and auto retrain or fallback / fallforward .............................62
Compression control .................................................................................................................................63
+DS - set data compression...................................................................................................................63
+DR - data compression reporting ........................................................................................................63
Break control.............................................................................................................................................64
\B - transmit break to remote.................................................................................................................64
\K - break handling................................................................................................................................64
S parameters..............................................................................................................................................65
S0 - number of rings to auto answer .....................................................................................................65
S1 - ring counter....................................................................................................................................65
S2 - escape character.............................................................................................................................66
S3 - carriage return character ................................................................................................................66
S4 - line feed character..........................................................................................................................67
S5 - backspace character .......................................................................................................................67
S7 - wait time for carrier, silence or dial tone .......................................................................................68
S10 - lost carrier to hang up delay.........................................................................................................68
S12 - escape prompt delay ....................................................................................................................69
S25 - delay to DTR off......................................................................................................................69
S30 - disconnect inactivity timer.......................................................................................................70
S38 - delay before forced hang up ....................................................................................................70
5.4
ETSI GSM 07.07 AT Commands ..................................................................................................................71
5.4.1
General......................................................................................................................................................71
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 4 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.4.1.1
5.4.1.2
5.4.1.3
5.4.1.4
5.4.1.5
5.4.1.6
5.4.2
5.4.2.1
5.4.2.2
5.4.2.3
5.4.2.4
5.4.2.5
5.4.3
5.4.3.1
5.4.3.2
5.4.3.3
5.4.3.4
5.4.3.5
5.4.3.6
5.4.3.7
5.4.3.8
5.4.3.9
5.4.3.10
5.4.3.11
5.4.3.12
5.4.3.13
5.4.3.14
5.4.3.15
5.4.4
5.4.4.1
5.4.4.2
5.4.4.3
5.4.4.4
5.4.4.5
5.4.4.6
5.4.4.7
5.4.4.8
5.4.4.9
5.4.4.10
5.4.4.11
5.4.4.12
5.4.4.13
5.4.4.14
5.4.4.15
5.4.4.16
5.4.4.17
5.4.5
5.4.5.1
5.4.5.2
5.4.6
5.4.6.1
5.4.7
5.4.7.1
5.4.7.2
5.4.7.3
5.4.7.4
5.4.7.5
+CGMI - request manufacturer identification.......................................................................................71
+CGMM - request model identification................................................................................................71
+CGMR - request revision identification..............................................................................................71
+CGSN - request product serial number identification.........................................................................71
+CSCS - select TE character set ...........................................................................................................71
+CIMI - request international mobile subscriber identity (IMSI) .........................................................73
Call control................................................................................................................................................74
+CBST - select bearer service type .......................................................................................................74
+CRLP - radio link protocol .................................................................................................................75
+CR - service reporting control............................................................................................................76
+CEER - extended error report .............................................................................................................77
+CRC - cellular result codes .................................................................................................................78
Network service handling .........................................................................................................................79
+CNUM - subscriber number................................................................................................................79
+CREG - network registration report....................................................................................................80
+COPS - operator selection...................................................................................................................82
+CLCK - facility lock/ unlock ..............................................................................................................83
+CPWD - change facility password ......................................................................................................83
+CLIP - calling line identification presentation ....................................................................................85
+CLIR - calling line identification restriction.......................................................................................86
+CCFC - call forwarding number and conditions .................................................................................87
+CCWA - call waiting ..........................................................................................................................89
+CHLD - call holding services..........................................................................................................89
+CUSD - unstructured supplementary service data ..........................................................................91
+CAOC - advice of charge................................................................................................................92
+CLCC - list current calls ................................................................................................................93
+CSSN – SS Notification..................................................................................................................93
+CCUG – Closed User Group supplementary service control ............................................................95
Mobile Equipment control ........................................................................................................................96
+CPAS - phone activity status .............................................................................................................96
+CFUN Set phone functionality (Power Saving Management) ............................................................96
+CPIN - enter PIN.................................................................................................................................98
+CSQ- signal quality.............................................................................................................................99
+CPBS - select phonebook memory storage .......................................................................................100
+CPBR - read phonebook entries........................................................................................................101
+CPBF - find phonebook entries.........................................................................................................102
+CPBW - write phonebook entry........................................................................................................103
+CCLK - Clock Management .............................................................................................................104
+CALA - Alarm Management ........................................................................................................105
+CALM - alert sound mode ............................................................................................................107
+CRSL - ringer sound level ............................................................................................................107
+CLVL - loudspeaker volume level................................................................................................107
+CMUT - microphone mute control ...............................................................................................108
+CACM - accumulated call meter ..................................................................................................109
+CAMM - accumulated call meter maximum.................................................................................109
+CPUC - price per unit and currency table .....................................................................................109
Mobile equipment errors.........................................................................................................................111
+CMEE - report mobile equipment error............................................................................................111
+CME ERROR: - ME error result code ..............................................................................................112
Voice Control (TIA IS-101)....................................................................................................................113
+VTS: - DTMF tones transmission.....................................................................................................113
Commands For GPRS.............................................................................................................................114
+CGACT - PDP context activate or deactivate...................................................................................114
+CGATT - GPRS attach or detach......................................................................................................115
+CGDATA - Enter data state ..............................................................................................................116
+CGDCONT - define PDP context.....................................................................................................117
+CGPADDR - show PDP address ......................................................................................................117
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 5 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.4.7.6
+CGREG - GPRS network registration status ....................................................................................119
5.4.7.7
+CGQMIN - quality of service profile (minimum acceptable)...........................................................119
5.4.7.8
+CGQREQ - quality of service profile (requested).............................................................................121
5.4.8
Commands For Battery Charger .............................................................................................................122
5.4.8.1
+CBC - Battery Charge.......................................................................................................................122
5.5
ETSI GSM 07.05 AT Commands for SMS and CB services .....................................................................123
5.5.1
General configuration .............................................................................................................................123
5.5.1.1
+CSMS - select message service.........................................................................................................123
5.5.1.2
+CPMS - preferred message storage ...................................................................................................124
5.5.1.3
+CMGF - message format...................................................................................................................125
5.5.1.4
+CSMP – Set parameters in text mode ...............................................................................................125
5.5.1.5
+CSDH – Show parameters in text mode ...........................................................................................125
5.5.1.6
+CSAS – Save setting text mode ........................................................................................................126
5.5.1.7
+CRES – Restore text mode settings ..................................................................................................126
5.5.1.8
+CSCB – Select Cell Broadcast Message types..................................................................................127
5.5.1.9
+CMS ERROR - message service failure result code .........................................................................128
5.5.2
Message configuration ............................................................................................................................129
5.5.2.1
+CSCA - service center address..........................................................................................................129
5.5.3
Message receiving and reading ...............................................................................................................130
5.5.3.1
+CNMI - new message indications to Terminal Equipment ...............................................................130
5.5.3.2
+CMGL - list messages.......................................................................................................................133
5.5.3.3
+CMGR - read message ......................................................................................................................135
5.5.4
Message sending and writing ..................................................................................................................137
5.5.4.1
+CMGS - send message ......................................................................................................................137
5.5.4.2
+CMSS - send message from storage .................................................................................................137
5.5.4.3
+CMGW - write message to memory ................................................................................................139
5.5.4.4
+CMGD - delete message ...................................................................................................................139
5.6
Custom AT Commands ................................................................................................................................141
5.6.1
General configuration .............................................................................................................................141
5.6.1.1
#CGMI - request manufacturer identification .....................................................................................141
5.6.1.2
#CGMM - request model identification ..............................................................................................141
5.6.1.3
#CGMR - request revision identification ............................................................................................141
5.6.1.4
#CGSN - request product serial number identification .......................................................................141
5.6.1.5
#CIMI - request international mobile subscriber identity (IMSI) .......................................................142
5.6.1.6
#CAP - Change Audio Path ................................................................................................................142
5.6.1.7
#SRS - Select ringer sound .................................................................................................................143
5.6.1.8
#SRP –Select Ringer Path...................................................................................................................144
5.6.1.9
#STM - Signalling Tones Mode..........................................................................................................145
5.6.1.10
#PCT – display PIN Counter...........................................................................................................145
5.6.1.11
#SHDN – Software Shut Down ......................................................................................................146
5.6.1.12
#WAKE – Wake from Alarm mode................................................................................................147
5.6.1.13
#QTEMP –Query Temperature overflow........................................................................................148
5.6.1.14
#SGPO –Set General Purpose Output .............................................................................................149
5.6.1.15
#GGPI – Read General Purpose Input ............................................................................................150
5.6.1.16
#GPIO –General Purpose Input/Output pin control ........................................................................151
5.6.1.17
#ADC – Read Analog/Digital Converter input ...............................................................................153
5.6.1.18
#MONI – Monitor Cells..................................................................................................................154
5.6.1.19
#QSS – Query SIM Status...............................................................................................................154
5.6.1.20
#ACAL – Set Automatic Call .........................................................................................................156
5.6.1.21
#SMOV – SMS Overflow...............................................................................................................157
5.6.1.22
#SHFEC – Set Handsfree echo canceller ........................................................................................157
5.6.1.23
#HFMICG – Handsfree Microphone Gain......................................................................................158
5.6.1.24
#HSMICG – Handset Microphone Gain .........................................................................................158
5.6.1.25
#SHFSD – Set Handsfree side tone.................................................................................................158
5.6.1.26
#/ – Repeat last command ...............................................................................................................159
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 6 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.6.1.27
#BND – Select Band (DCS 1800 or PCS 1900) ............................................................................160
5.7
FAX Class 1 Commands...............................................................................................................................161
5.7.1
General configuration .............................................................................................................................161
5.7.1.1
+FCLASS - select active service class ................................................................................................161
5.7.1.2
+FMI – Report manufacturer ID .........................................................................................................162
5.7.1.3
+FMM? – Report model ID ................................................................................................................162
5.7.1.4
+FMR – Report revision ID ................................................................................................................163
5.7.2
Transmission/Reception control..............................................................................................................163
5.7.2.1
+FTS – Stop Transmission and pause .................................................................................................163
5.7.2.2
+FRS – Wait for receive silence .........................................................................................................164
5.7.2.3
+FTM – Transmit data modulation .....................................................................................................164
5.7.2.4
+FRM – Receive data modulation ......................................................................................................164
5.7.2.5
+FTH – Transmit data with HDLC framing .......................................................................................165
5.7.2.6
+FRH – Receive data with HDLC framing.........................................................................................166
5.7.3
Serial port control ...................................................................................................................................166
5.7.3.1
+FLO – Select flow control specified by type ....................................................................................166
5.7.3.2
+FPR – Select serial port rate..............................................................................................................166
5.7.3.3
+FDD – Double escape character replacement control.......................................................................167
5.8
Easy GPRS Extension...................................................................................................................................168
5.8.1
Overview.................................................................................................................................................168
5.8.2
Easy GPRS definition .............................................................................................................................168
5.8.2.1
Configuring the GPRS access .............................................................................................................169
5.8.2.2
Configuring the embedded TCP/IP stack............................................................................................169
5.8.2.3
Defining the Internet peer to be contacted ..........................................................................................169
5.8.2.4
Open the connection with the internet host .........................................................................................169
5.8.2.5
Close the Socket and deactivate the context .......................................................................................169
5.8.3
Known limitations...................................................................................................................................169
5.8.4
Easy GPRS custom AT command Definition .........................................................................................170
5.8.4.1
#USERID – Authentication User ID control.......................................................................................170
5.8.4.2
#PASSW – Authentication Password control .....................................................................................171
5.8.4.3
#PKTSZ –Packet Size control.............................................................................................................172
5.8.4.4
#DSTO – Data Sending Timeout control ............................................................................................173
5.8.4.5
#SKTTO – Socket inactivity timeout control......................................................................................174
5.8.4.6
#SKTSET – Socket definition control ................................................................................................175
5.8.4.7
#SKTOP – Socket Open command.....................................................................................................176
5.8.4.8
#QDNS – Query DNS.........................................................................................................................176
5.8.4.9
#SKTSAV – Socket Parameters Save Command ...............................................................................176
5.8.4.10
#SKTRST – Socket Parameters Reset Command ...........................................................................178
5.9
Easy Camera Extension................................................................................................................................179
5.9.1
Camera management...............................................................................................................................179
5.9.1.1
#CAMON – Camera ON....................................................................................................................179
5.9.1.2
#CAMOFF – Camera OFF.................................................................................................................179
5.9.1.3
#TPHOTO – Camera Take Photo .......................................................................................................180
5.9.1.4
#RPHOTO – Camera Read Photo.......................................................................................................180
5.9.1.5
#OBJL – Object List ...........................................................................................................................181
5.9.1.6
#OBJR – Object Read .........................................................................................................................181
5.9.1.7
#CAMQUA – Camera Select Quality of Photo ..................................................................................182
5.9.1.8
#CMODE – Camera Select Operating MODE....................................................................................183
5.9.2
Email management..................................................................................................................................184
5.9.2.1
#ESMTP – Email SMTP server ..........................................................................................................184
5.9.2.2
#EADDR – Email sender address .......................................................................................................185
5.9.2.3
#EUSER – Email authentication USER NAME .................................................................................186
5.9.2.4
#EPASSW – Email authentication PASSWORD ...............................................................................187
5.9.2.5
#SEMAIL - Send Email ......................................................................................................................188
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 7 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.10
Easy Scan Extension .....................................................................................................................................189
5.10.1
Easy Scan custom AT commands ...........................................................................................................189
5.10.1.1
*CSURV - Network Survey of the complete 900/1800/1900 Network ..........................................189
5.10.1.2
*CSURVC - Network Survey in computer friendly format ............................................................191
5.10.1.3
*CSURVU - Network Survey of user defined 900/1800/1900 channels ........................................192
5.10.1.4
*CSURVUC - Network Survey in computer friendly format .........................................................193
5.11
Jammed Detect & Report Extension ...........................................................................................................194
5.11.1
Overview.................................................................................................................................................194
5.11.2
Jammed Detect & Report custom AT commands ...................................................................................194
5.11.2.1
#JDR - Jammed Detect & Report....................................................................................................194
CONFORMITY ASSESSMENT ISSUES ................................................................ 196
6.1
TRIZIUM: Conformity Assessment ............................................................................................................197
6.2
TRIZIUM: FCC Equipment Authorization ...............................................................................................198
TRIZIUM TECHNICAL SUPPORT........................................................................... 199
LIST OF ACRONYMS ............................................................................................. 200
DOCUMENT CHANGE LOG ................................................................................... 202
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 8 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
1 Overview
Aim of this document is the description of features, functions and interfaces of the Telit TRIZIUM
modules.
The Telit TRIZIUM modules are small, lightweight and low power consumption devices that allow
digital communication services wherever a GSM 900, DCS 1800, PCS1900 network is present.
Based on the long experience of the Telit GM862 module family; TRIZIUM modules are the low cost
connector-less best solution for medium to high quantity project. Moreover, customer with
experience in Telit GM862 module family can take advantage of that thank to the SW high backward
compatibility.
The Telit TRIZIUM module includes features like GPRS, Voice, Circuit Switch Data transfer, Fax,
Phonebook and SMS support, ‘Easy GPRS’ embedded TCP/IP stack and ‘EASY CAMERA’,
battery charging capabilities
It is specifically designed and developed by Telit for OEM usage and dedicated to portable data,
voice and telematics applications needing the added triband and GPRS Class 10 improved speed
features and the battery charger such as:
Fast Worldwide GPRS Telemetry and Telecontrol (SCADA applications)
Worldwide Smart GPRS Security systems
Worldwide Smart GPRS Vending machines
Fast Worldwide GPRS POS terminals
Worldwide PDAs
Worldwide Phones and Payphones
Worldwide Smart Automotive and Fleet Management applications
Battery powered applications needing a battery charger
The Telit TRIZIUM modules will evolve in future in order to face the competitive
telecommunication market requirements supporting the new incoming standards:
Bluetooth support
GPS embedded functionality
In order to meet the competitive OEM and vertical market stringent requirements, Telit supports its

customers with a dedicated TRIZIUM Module Support Policy with:
an Evaluation Kit to help you develop you application;
a dedicated Website (www.TRIZIUM.com) with all updated information available;
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 9 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
a high level specialist technical support to assist you in your development;
free SW releases upgrade download (via the Website) every time a new functionality will be
added to the Telit modules SW.
For more updated information concerning product Roadmap and availability, technical
characteristics, commercial and other issues please check the Telit TRIZIUM modules dedicated
Website www.TRIZIUM.com or mail to:
ts-trizium@telit.net, for any Technical information or support you may need
ci-trizium@telit.net, for any Commercial, sales or marketing related info
af-trizium@telit.net , for After Sales issues
NOTE: Some of the performances of the Telit TRIZIUM modules depend on SW version
installed on the module itself. In particular on Chapter 5, dedicated to the supported AT
commands, the minimum SW version required to support each specific AT command is
reported.
The Telit TRIZIUM modules SW group is continuously working in order to add new features
and improve the overall performances. From time to time that a new SW version is released, it
will be freely distributed by the Telit TRIZIUM module dedicated Website
The Telit TRIZIUM modules are easily upgradeable by the developer using the Telit TRIZIUM
module Flash Programmer.
For more info about this topic (and not only !) please check Telit TRIZIUM modules dedicated
Website www.TRIZIUM.com. and www.telit.net
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 10 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2 General Product Description
2.1 Dimensions
The Telit TRIZIUM module overall dimension are:
• Lenght:
41,4 mm
• Width:
31,4 mm
• Thickness:
3,6 mm
The layout of Telit TRIZIUM module is shown in the following figure:
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 11 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Bottom View
2.2 Weight
The Telit TRIZIUM module weight is 9 gr.
2.3 Environmental requirements
The Telit TRIZIUM module is compliant with the applicable ETSI reference documentation GSM 05.05 Release1999
ETSI EN300910 V8.4.1
2.3.1Temperature range
•
•
•
Temperature in normal functional conditions
–10°C ÷ +55°C
Temperature in extreme functional conditions* –25°C ÷ +75°C
Temperature in storage conditions
–30°C ÷ +85°C
*these temperature can affect the sensitivity and performance of the module
2.3.2Vibration Test (non functional)
•
•
10 ÷12Hz ASD = 1.92m 2 /s 3
12 ÷ 150Hz –3dB/oct
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 12 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.4 Operating Frequency
The operating frequencies in GSM, DCS, PCS modes are conform to the GSM specifications.
Mode
Freq. TX (MHz)
Freq. RX (MHz)
Channels (ARFC)
TX - RX offset
E-GSM-900
890.0 - 914.8
935.0 - 959.8
0 – 124
45 MHz
880.2 - 889.8
925.2 - 934.8
975 - 1023
DCS-1800
1710.2 - 1784.8
1805.2 - 1879.8
512 – 885
95 MHz
PCS-1900
1850.2 - 1909.8
1930.2 - 1989.8
512 - 810
80 MHz
2.5 Transmitter output power
GSM–900
The Telit TRIZIUM transceiver module in GSM–900 operating mode are of class 4 in accordance with the specification
which determine the nominal 2W peak RF power (+33dBm) on 50 Ohm.
DCS–1800
The Telit TRIZIUM transceiver module in DCS–1800 operating mode are of class 1 in accordance with the specifications
which determine the nominal 1W peak RF power (+30dBm) on 50 Ohm.
PCS–1900
The Telit TRIZIUM transceiver module in PCS–1900 operating mode are of class 1 in accordance with the specifications
which determine the nominal 1W peak RF power (+30dBm) on 50 Ohm.
2.6 Reference sensitivity
GSM–900
The sensitivity of the Telit TRIZIUM transceiver module according to the specifications for the class 4 GSM–900
portable terminals is better than –102dBm in all the operational conditions.
DCS–1800
The sensitivity of the Telit TRIZIUM transceiver module according to the specifications for the class 1 portable terminals
GSM 1800 is better than –102dBm in normal operating conditions.
PCS–1900
The sensitivity of the Telit TRIZIUM transceiver module according to the specifications for the class 1 portable terminals
PCS 1900 is better than –102dBm in normal operating conditions.
2.7 Antenna
The antenna that the customer chooses to use, depending on his application, should fulfil the
following requirements:
Frequency range
Bandwith
Gain
Impedance
Input power
VSWR absolute max
VSWR recommended
Standard Dual Band frequency range,
Standard Tri Band frequency range
80 MHz in GSM & 170 MHz in DCS & 140 MHz
PCS band
> 0 dBi; < 3 dBi
50 ohm
> 2 W peak power
<= 10:1
<= 2:1
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 13 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.7.1 Antenna connector
N/A
2.8 Supply voltage
The external power supply must be connected to VBATT signal (see paragraph 2.16,) and must fulfil the following
requirements:
•
•
Nominal operating voltage
Operating voltage range
3.8 V
3.4 V - 4.2 V
Note: Operating voltage range must never be exceeded, care must be taken in order to fulfill min/max voltage
requirements.
2.9 Power consumption
The typical current consumption of the Telit TRIZIUM module are:
•
•
•
•
•
Power off current (typical)
< 30 µA;
Stand–by current
< 19 mArms (< 4 mArms using command AT+CFUN )
Operating current
in voice ch.
170 mArms @ typical network conditions
Operating current
in voice ch.
< 270 mArms 1.9 Apeak @ worst network conditions
Operating current in GPRS class 10 < 500 mArms @ typical network conditions
2.10
Embodied Battery charger
The battery charger is suited for 3.7V Li-Ion rechargeable battery (suggested capacity 500-1000mAH). The Charger
needs only a CURRENT LIMITED power source input and charges the battery directly through VBATT connector
pins.
• Battery charger input pin
CHARGE
• Battery pins
VBATT, GND
• Battery charger input voltage min
5.0 V
• Battery charger input voltage typ
5.5 V
• Battery charger input voltage max
7.0 V
• Battery charger input current max
400mA
• Battery type
Li-Ion rechargeable
NOTE: If embodied battery charger is used, then a LOW ESR capacitor of at least 100µF must be mounted in parallel
to VBATT TRIZIUM pins.
NOTE: when power is supplied to the CHARGE pin, a battery must always be connected to the VBATT pins of the
TRIZIUM.
2.11
User Interface
The user interface is managed by AT commands specified on the GSM 07.07 and 07.05 specification and listed in the
chapter 5, AT Command.
2.11.1
Speech Coding
The Telit TRIZIUM modules vocoder supports the following rates:
• Half Rate.
• Full rate,
• Enhanced Full Rate
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 14 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.11.2
Sim Reader
The Telit TRIZIUM modules support phase 2 GSM11.14 - SIM 3V volts ONLY with and external SIM connector. For 5V
SIM operation an external level translator can be added.
2.11.3
SMS
The Telit TRIZIUM module supports the following SMS types:
Mobile Terminated (MT) class 0 – 2 with signaling of new incoming SMS, SIM full, SMS read
Mobile Originated class 0 – 3 with writing, memorize in SIM and sending
Cell Broadcast compatible with CB DRX with signaling of new incoming SMS.
2.11.4
Real Time Clock and Alarm
The Telit TRIZIUM module supports the Real Time Clock and Alarm functions through AT commands, furthermore an
alarm output pin (GPIO6) can be configured to indicate the alarm with a hardware line output.
Furthermore the Voltage Output of the RTC power supply is provided so that a backup capacitor can be added to
increase the RTC autonomy.
2.11.5
Data/fax transmission
The Telit TRIZIUM module supports:
• Packed Data transfer GPRS Class B, Multislot Class 10
• Data transmission according to the GSM 07.07, 07.05
• CSD up to 14.4 Kbps
• Fax service, Class 1 Group 3
• Fax service, Class 2 Group 3 (future SW release)
2.11.6
Local security management
With lock of Subscriber Identity module (SIM), and security code request at power–up.
2.11.7
Call control
Call cost control function.
2.11.8
Phonebook
Function available to store the telephone numbers in SIM memory.
Capability depends on SIM version/memory
2.11.9
Characters management
Availability of lowercase, uppercase and IRA characters. (international reference alphabet)
In SMS PDU mode all character set are supported.
2.11.10 SIM related functions
Activation/deactivation of the numbers stored in phone book FDN, ADN and PINs. Extension at the PIN2 for the PUK2
insertion capability for lock condition.
2.11.11 Call status indication
By AT commands.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 15 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.11.12 Indication of network service availability
By AT commands and LED indication on dedicated output.
The STAT_LED is an Open Collector output where it is possible to directly connect a LED to show information on the
network service availability and Call status.
STAT_LED indications
LED status
Device Status
permanently off
device off
fast blinking
(period 1s, Ton 0,5s)
slow blinking
(period 3s, Ton 0,3s)
Permanently on
Net search / Not
registered / turning off
Registered full service
a call is active
2.11.13 Automatic answer (Voice, Data or FAX)
After n (depends of settings) rings automatically answers with beep (see S0 param).
2.11.14 Supplementary services (SS)
•
•
•
•
•
•
•
•
Call Barring,
Call Forwarding,
Calling Line Identification Presentation (CLIP),
Calling Line Identification Restriction (CLIR),
Call Waiting, other party call Waiting Indication,
Call Hold, other party Hold / Retrieved Indication,
Closed User Group supplementary service (CUG),
Advice of Charge,
•
Unstructured SS Mobile Originated (MO)
2.11.15 Acoustic signaling
The acoustic signalling of Telit TRIZIUM module on the selected acoustic device are the following:
•
•
•
•
•
•
•
•
•
•
•
Call waiting;
Ringing tone;
SMS received tone;
Busy tone;
Power on/off tone;
Off Hook dial tone;
Congestion tone;
Connected tone;
Call dropped;
No service tone;
Alarm tone.
2.11.16 DTMF tones
DTMF tones managed by specific AT commands.
These tones are generated with AT commands only during voice calls.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 16 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
The minimum duration of a DTMF tone is 100 ms.
Group high
Group low
1209 Hz
1336 Hz
1477 Hz
697 Hz
770 Hz
852 Hz
941 Hz
2.11.17 Buzzer output
The General Purpose I/O pin GPIO7 can be configured to output the BUZZER output signal, with only an external
Mosfet/transistor and a diode a Buzzer can be directly driven.
The ringing tone and the other signaling tones can be redirected to this Buzzer output with a specific AT command.
2.12
Logic level specifications
Where not specifically stated, all the interface circuits work at 2.8V CMOS logic levels.
The following table shows the logic level specifications used in the Telit TRIZIUM module interface circuits:
Absolute Maximum Ratings -Not Functional
Parameter
Min
Max
Input level on any digital -0.3V
pin when on
Input voltage on analog -0.3V
pins when on
+3.75V
+3.0 V
Operating Range - Interface levels (2.8V CMOS)
Level
Min
Max
Input high level
2.1V
3.3V
Input low level
0V
0.5V
Output high level
2.2V
3.0V
Output low level
0V
0.35V
For 2,0V signals:
Operating Range - Interface levels (2.0V CMOS)
Level
Min
Max
Input high level
1.6V
3.3V
Input low level
0V
0.4V
Output high level
1,65V
2.2V
Output low level
0V
0.35V
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 17 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.12.1
Reset signal
Signal
Function
I/O
Pin
RESET
Phone reset
I/O
23 (connector SO301)
RESET is used to reset the Telit TRIZIUM module. Whenever this signal is pulled low, the TRIZIUM
is reset. When the device is reset it stops any operation and after the release of the reset it shuts
down, without doing any detach operation from the network where it is registered to. This behavior
is not a proper shut down because any GSM device is requested to issue a detach request on turn
off. For this reason the Reset signal must not be used to normally shutting down the device, but
only as an emergency exit in the rare case the device remains stucked waiting for some network
response.
The RESET is internally controlled on start-up to achieve always a proper power-on reset sequence,
so there's no need to control this pin on start-up. It may only be used to reset a device already on
that is not responding to any command.
NOTE: do not use this signal to power off the Telit TRIZIUM module. Use the ON/OFF signal
(Pin 17 of SO301) to perform this function or the AT#SHDN command.
Reset Signal Operating levels:
Signal
Min
Max
RESET Input high
2.2V*
3.3V
RESET Input low
0V
0.2V
* this signal is internally pulled up so the pin can be left floating if not used.
If unused, this signal may be left unconnected. If used, then it must always be connected with an open collector
transistor, to permit to the internal circuitry the power on reset and undervoltage lockout functions.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 18 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.13
RTC Bypass out
The PIN VRTC brings out the Real Time Clock supply which is separate from the rest of the digital part, allowing to
have only RTC going on when all the other parts of the device are off.
To this power output a backup capacitor can be added in order to increase the RTC autonomy during power off of the
battery. NO Devices must be powered from this pin.
2.14
Vout power output
A regulated power supply output is provided in order to supply small devices from module.
This output is active when the module is ON and goes off when module is shut down.
The operating range characteristics of the supply are:
Operating Range - Vout power supply
Min
Output voltage
2.75V
Typ
Max
2.85V
2.95V
Output current
100mA
Output bypass capacitor
2.2µF
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 19 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.15
Audio levels specifications
The audio of the Telit TRIZIUM module is organized into two main paths:
- internal path (called also MT)
- external path (called also HF)
These two paths are meant respectively for handset and headset/handsfree use.
The Telit TRIZIUM module has a built in echo canceller and a noise suppressor, tuned separately for the two audio paths;
for the internal path the echo canceller parameters are suited to cancel the echo generated by a handset, while for the
external audio path they are suited for a handsfree use.
For more information on the audio refer to the Hardware User Guide.
The following table reports all the audio level specifications.
Microphone characteristics
Line coupling
Internal audio mic. input
AC ( 100nF cond.)
External audio mic. input
AC ( 100nF cond.)
Line type
Balanced
Balanced
Differential input resistance
Line nominal sensitivity
Max input voltage
Microphone nominal sensitivity
Analog Gain suggested
Echo canceller type
25kΩ
50mVrms
360mVrms
- -45dBVrms/Pa / +24dB
25kΩ
3mVrms
22mVrms
-45dBVrms/Pa / +10dB
handset
Car kit hands free
Line type
Internal audio ear. output
DC
Bridged
External audio ear. output
DC
Bridged
Speaker impedance
Minimun load impedance
Signal bandwidth
Maximum output
Maximum power output
Volume level steps (SW)
Number of volume steps (SW)
≥ 16Ω ± 5% @ 1kHz
15Ω
150-8000 Hz @ -3dB
1700mVrms
30mW
-2dB
10
≥ 16Ω ± 5% @ 1kHz
15Ω
150-8000 Hz @ -3dB
850mVrms
7.5mW
-2dB
10
Speaker characteristics
Line coupling
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 20 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.16
Interfaces on TRIZIUM
TRIZIUM PIN-OUT
Pin Signal
I/O
Function
I/O
Port D5 / GPIO13 (4)
CMOS 2.8V
I/O
Port D4 / GPIO12 (4)
CMOS 2.8V
I/O
Port D3 / GPIO11 (4)
CMOS 2.8V
I/O
Port D2 / GPIO10 (4)
CMOS 2.8V
I/O
Port D1 / GPIO9 (4)
CMOS 2.8V
I/O
Port D0 / GPIO8 (4)
CMOS 2.8V
PD5
GPIO13
PD4
GPIO12
PD3
GPIO11
PD2
GPIO10
PD1
GPIO9
PD0
GPIO8
MON1_CAM
I/O
Camera clock (4)
CMOS 2.8V
GND
Ground
Power
EAR_MT-
AO
Handset earphone signal output, phase -
Audio
10
EAR_MT+
AO
Handset earphone signal output, phase +
Audio
11
EAR_HF+
AO
Handsfree ear output, phase +
Audio
12
EAR_HF-
AO
Handsfree ear output, phase -
Audio
13
MIC_MT+
AI
Audio
14
MIC_MT-
AI
15
MIC_HF+
AI
16
MIC_HF-
AI
17
GND
Handset microphone signal input; phase+, nominal level
50mVrms
Handset microphone signal input; phase-, nominal level
50mVrms
Handsfree microphone input; phase +, nominal level
3mVrms
Handsfree microphone input; phase -, nominal level
3mVrms
Ground
18
SIMCLK
External SIM signal – Clock
3V ONLY
19
SIMRST
External SIM signal – Reset
3V ONLY
20
SIMIO
I/O
External SIM signal - Data I/O
3V ONLY
21
CCIN
I/O
External SIM signal - Presence (active low)
22
SIMVCC
External SIM signal – Power (3)
3V ONLY
23
ADC
AI
Analog/Digital converter input
A/D
24
VBATT
Main power supply
Power
25
TX_TRACE
TX Data for debug monitor (1)
CMOS 2.8V
26
RX_TRACE
RX Data for debug monitor (1)
CMOS 2.8V
27
VRTC
AO
VRTC Backup capacitor
Power
28
GND
Ground
Power
29
STAT_LED
Status indicator led
CMOS 2.8V
Internal
Pull up
Type
Audio
Audio
Audio
Power
47KΩ
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
CMOS 2.8V
page 21 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
30
AXE
Handsfree switching
31
VOUT
Power output for external accessories (camera)
32
IICSDA GPIO4 I/O
CMOS 2.8V
33
IICSCL GPIO2 I/O
34
GPIO1
I/O
Camera IIC interface / GPIO4 Configurable general
purpose I/O pin (4)
Camera IIC interface / GPIO2 Configurable general
purpose I/O pin (4)
GPIO1 Configurable general purpose I/O pin
CMOS 2.8V
35
CHARGE
AI
Charger input
Power
36
GND
Ground
Power
37
C103/TXD
Serial data input (TXD) from DTE
CMOS 2.8V
38
C104/RXD
Serial data output to DTE
CMOS 2.8V
39
C108/DTR
Input for Data terminal ready signal (DTR) from DTE (4)
CMOS 2.8V
40
C105/RTS
Input for Request to send signal (RTS) from DTE
CMOS 2.8V
41
C106/CTS
Output for Clear to send signal (CTS) to DTE
CMOS 2.8V
42
C109/DCD
Output for Data carrier detect signal (DCD) to DTE
CMOS 2.8V
43
C107/DSR
Output for Data set ready signal (DSR) to DTE
CMOS 2.8V
44
C125/RING
Output for Ring indicator signal (RI) to DTE
CMOS 2.8V
45
GND
Ground
Power
46
ON/OFF
Pull up to VBATT
47
RESET
Input command for switching power ON or OFF (toggle 47KΩ
command). The pulse to be sent to the TRIZIUM must be
equal or greater than 1 second.
Reset input
2KΩ
48
GND
Ground
Power
49
ANTENNA
Antenna output - 50 ohm
RF
50
GND
Ground
Power
51
OE_CAM
GPIO7
CAM_SYNC
I/O
Output Enable Camera / GPIO7 (4)
CMOS 2.8V
I/O
Camera Sync (4)
CMOS 2.8V
CAM_DRDY
GPIO5
PD7
GPIO6
PD6
GPIO3
GND
I/O
Camera DRDY / GPIO5 (4)
CMOS 2.8V
I/O
Port D7 / GPIO6 (4)
CMOS 2.8V
I/O
Port D6 / GPIO3 (4)
CMOS 2.8V
Ground
Power
52
53
54
55
56
100KΩ
CMOS 2.8V
CMOS 2.8V
see par.2.12.1
(1) For the exclusive use of the Technical Support Service
(2) An earphone with a 150 ohm impedance can be directly connected to EAR+ and EAR–
(3) On this pin a maximum of 47nF bypass capacitor is allowed.
(4) When activating the Easy camera these pins will not be available for other use
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 22 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.17
Mounting the R
IZIUM on your Board
2.17.1
General
Trizium module has been designed in order to be compliant with a standard smt process, with the
following details.
2.17.2
Module finishing & dimensions
All quotes are in mm, general tolerance ± 0.1
Surface finishing Ni/Au for all test pads
(in white on the drawing).
Surface finishing Sn63/Pb37 for all solder pads
(in black on the drawing).
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 23 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.17.3
Recommended foot print for application
2.17.4
Stencil
Stencil’s apertures layout can be the same of the recommended footprint (1:1), we suggest a
thickness of stencil foil = 120µm.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 24 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.17.5
Solder reflow
The following is the recommended solder reflow profile
Temperature (ºC)
300
200
100
100
200
300
Time (sec)
NOTE : This is an ideal profile, and actual conditions obtained in any specific reflow oven will
vary. This profile is based on convection or RF plus forced convection heating.
NOTICE: Trizium module can accept only one reflow process
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 25 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.17.6
Packing system
170 ± 0,3
According to smt processes for pick & place mouvement requirements, Trizium modules are
packaged on trays, each tray contains 20 pieces. Tray dimensions are::
320 ± 0,3
Section A-A
All quotes are in mm, general tolerance ± 0.1
6.1
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 26 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Note that trays can withstand a maximum temperature of 65° C.
Modules orientation on tray:
Ref. No rounded corner on
module’s printed circuit
board indicates pin 1 corner
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 27 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
2.17.7
Moisture sensibility
The level of moisture sensibility of Trizium module is “3”, in according with standard IPC/JEDEC J-STD-020, take
care all the relatives requirements for using this kind of components.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 28 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
3 Evaluation Kit
In order to assist you in the development of your Telit TRIZIUM module based application, Telit can supply an Evaluation
Kit (same as used for the GM862 family, with a dedicated adaptor) with appropriate power supply, SIM card housing,
RS 232 serial port level translator, direct UART connection, Handset, Headset and Hands-free (car kit) audio, antenna.
The EVK provides a fully functional solution for a complete data/phone application.
The standard serial RS232 9 pin connector placed on the Evaluation Kit allows the connection of the
EVK system with a PC or other DTE.
The development of the applications utilizing the Telit TRIZIUM module must present a proper design
of all the interfaces towards and from the module (e.g. power supply, audio paths, level translators),
otherwise a decrease in the performances will be introduced or, in the worst case, a wrong design
can even lead to an operating failure of the module.
In order to assist the hardware designer in his project phase, the EVK board presents a series of
different solutions, which will cover the most common design requirements on the market, and
which can be easily integrated in the OEM design as building blocks or can be taken as starting
points to develop a specific one.
TRIZIUM Evaluation Kit (adaptor not shown)
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 29 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
3.1 Evaluation Kit description
For a detailed description of the Telit Evaluation Kit refer to the documentation provided with the Telit TRIZIUM
Hardware User Guide.
The Telit Evaluation Kit can be divided into different blocks depending on the function they implement.
A schematic showing the EVK board and its blocks is shown:
+12V
POWER SUPPLY
REGULATORS
SIM HOUSING
+5V
POWER SUPPLY
REGULATORS
ANTENNA COAX
FREE SPACE
BATTERY SUPPLY
& CHARGE CONTROL
RS232
LEVEL
TRANSLATOR
GPIO
TRIZIUM
ON/OFF
GPIO & LEDS
& RESET
BUTTONS
+3V UART
ADAPTOR
AUDIO/BF
FILTERS
HIGH POWER
EXT. EAR
EXT
EAR
BRIDGED
EXT
EAR
SINGLE
ENDED
EVK
EXT
HANDSET HANDSET EXT
MIC
EAR
EAR
MIC
UNBAL
BRIDGED SINGLE
BALAN
ANCE
ENDED
CED
HANDSET
CONNECTOR
HAND
HAND
SET
SET
MIC
MIC
BALAN UNBAL
CED ANCE
3.1.1 Power Supply
In the Board there are three different power sources, that embrace a wide range of applications, from the automotive
+12V input to the stand alone battery powered device.
The power sources nominal input voltages are:
• +12V input (typically automotive)
• +5V input (typically embedded systems)
• +3.8V input (Li-Ion Battery)
Each one of these power sources can supply both the Telit TRIZIUM module and the whole circuitry embodied in the
Evaluation Kit.
Only one of these power sources can be used at a time and it is selectable with two jumpers.
For the battery power supply a Li-Ion battery charger circuit is provided.
3.1.2 Serial interface
The communications between your application and the Telit TRIZIUM module must be done through a serial interface
which can be a standard CMOS UART or a RS232 port.
All levels of the RS232 port are conform to RS232 and V.24 standard and a PC serial port can be directly connected to
this connector.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 30 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Both these interfaces are supported.
3.1.3 Audio
The Evaluation Kit board provides two software/hardware selectable audio paths, the internal and the external one. All
the handset, headset and hands free-car kit functions are supported.
Furthermore for each audio path two solution are presented: single ended and balanced.
3.1.4 GPIO and Leds
All the General Purpose Input Output ports of the Telit TRIZIUM module are supported in a dedicated connector and
several leds are added as a debug aid.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 31 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
4 Service and firmware update
The serial cable used for the communication with a PC can be also used to update the Telit TRIZIUM module firmware.
The RS232 connector DB type 9 pin 90° is used to connect the Telit Evaluation Kit. to any DTE .
All levels are conformed to RS232 and V.24 standard and a PC serial port can be directly connected to this connector.
The firmware update can be done with a specific software tool provided by Telit that runs on windows based PCs.
4.1 Step-by-Step upgrade procedure
I. Download the specific software for upgrading (Flash programmer TFI_TRIZIUM.zip).from the site
www.TRIZIUM.com, or request it at this e-mail address ts-trizium@telit.net
II. Unzip the file TFI_TRIZIUM.zip. A new folder TRIZIUM/ will be created
III. Mount the Telit TRIZIUM module in the Evaluation Kit (using the dedicated adaptor)and supply power
IV. Run the file TFI_TRIZIUM.exe.
V. Press the Start Procedure button and within 5 seconds press the ON/OFF button on the
board. Keep pressed the ON/OFF button for 5 seconds and then leave it.
First the program will erasure the content of flash memory
Then the program will write on the flash memory
Wait for the end of programming green message COK
Your Telit TRIZIUM module is now programmed with the new firmware.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 32 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5 AT Command
The Telit TRIZIUM module can be driven via the serial interface using the standard AT commands1. The Telit TRIZIUM
module is compliant with:
1. Hayes standard AT command set, in order to maintain the compatibility with existing SW programs.
2. ETSI GSM 07.07 specific AT command and GPRS specific commands.
3. ETSI GSM 07.05 specific AT commands for SMS (Short Message Service) and CBS (Cell Broadcast Service)
4. FAX Class 1 compatible commands
Moreover the Telit TRIZIUM module supports also Telit proprietary AT commands for special purposes.
In the following the dedicated description of how to use the AT commands with the Telit TRIZIUM module.
5.1 Definitions
The following syntactical definitions apply:
 Carriage return character, is the command line and result code terminator character, which value, in decimal
ASCII between 0 and 255,is specified within parameter S3.
The default value is 13.
 Linefeed character, is the character recognised as line feed character. Its value, in decimal ASCII between 0
and 255, is specified within parameter S4. The default value is 10.
The line feed character is output after carriage return character if verbose result codes are used (V1 option used )
otherwise, if numeric format result codes are used (V0 option used) it will not appear in the result codes.
<...> Name enclosed in angle brackets is a syntactical element. They do not appear in the command line.
[...] Optional subparameter of a command or an optional part of TA information response is enclosed in square
brackets. Brackets themselves do not appear in the command line. When subparameter is not given in AT commands
which have a read command, new value equals to its previous value. In AT commands which do not store the values of
any of their subparameters, and so have not a read command, which are called action type commands, action should be
done on the basis of the recommended default setting of the subparameter.
5.2 AT Command Syntax
GSM commands use syntax rules of extended commands.
Every extended command has a test command (trailing =?) to test the existence of the command and to give
information about the type of its subparameters. There are two types of extended command:
- Parameter type commands which also have a read command (trailing ?) to check the current values of
subparameters.
- Action type commands do not store the values of any of their possible subparameters, and therefore do not have a
read command.
5.2.1Command lines
The basic structure of the command lines are:
• ATCMD1 where AT is the command line prefix, CMD1 is a basic command (i.e. it have not + prefix) and
CR is the command line terminator character
• ATCMD2=10 where 10 is a subparameter
• AT+CMD1;+CMD2=, ,10 These are two examples of extended commands (which have a + prefix). They are
delimited with semicolon. In the second command the subparameter is omitted
• +CMD1? This is a read command for checking current subparameter values
The AT is an ATTENTION command and is used as a prefix to other parameters in a string. The AT command
combined with other parameters can be set up in the communications package or typed in manually as a command line
instruction.
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 33 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
• +CMD1=? This is a test command for checking possible subparameter values
These commands might be performed in a single command line as shown below:
ATCMD1 CMD2=10+CMD1;+CMD2=, ,10;+CMD1?;+CMD1=?
anyway it is always preferable to separate into different command lines the basic commands (i.e. without + prefix) and
the extended commands (the ones with + prefix); furthermore it is suggested to avoid placing several action commands
in the same command line, because if one of them fails, then an error message is received but it is not possible to argue
which one of them has failed the execution.
If command V1 is enabled (verbose responses codes) and all commands in a command line has been performed
successfully, result code OK is sent from the TA to the TE, if subparameter values of a
command are not accepted by the TA or command itself is invalid, or command cannot be performed for some reason,
result code ERROR is sent and no subsequent commands in the command line are processed.
If command V0 is enabled (numeric responses codes), and all commands in a command line has been performed
successfully, result code 0 is sent from the TA to the TE, if sub-parameter values of a command are not accepted
by the TA or command itself is invalid, or command cannot be performed for some reason, result code 4 and no
subsequent commands in the command line are processed.
In case of errors depending on ME operation, ERROR (or 4) response may be replaced by +CME ERROR:  or
+CMS ERROR: .
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 34 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.2.2 Information responses and result codes
The TA response, in case of verbose response format enabled, for the previous examples command line could be as
shown below:
information response to +CMD1?
+CMD1:2,1,10
information response to +CMD1=?
+CMD1(0-2),(0,1),(0-15)
final result code
OK
Moreover there are other two types of result codes:
•
result codes that inform about progress of TA operation (e.g. connection establishment CONNECT)
•
result codes that indicate occurrence of an event not directly associated with issuance of a command from TE (e.g.
ring indication RING).
Here the basic result codes according to ITU-T V25Ter recommendation
Result Codes
Numeric form
Verbose form
OK
CONNECT
RING
NO CARRIER
ERROR
NO DIALTONE
BUSY
NO ANSWER
5.2.3 Command Response Timeout
Every command issued to the Telit TRIZIUM module returns a result response if response codes are enabled (default). The
time needed to process the given command and return the response varies from command to command and may depend
also from the network on which the command may interact. As a result every command is provided with a proper
timeout time, if this time elapses without any result from the operation, then an ERROR response can be reported as if
the operation was not successful and the operation is anyway terminated.
The timeout time is quite short for commands that imply only internal set up commands, but may be very long for
command that interact with the network (or even a set of Networks).
The default timeout is 100 ms for all the commands that have no interaction with the network or upper software layers.
In the table below are listed all the commands whose timeout differs from the default 100 ms and their effective timeout
is reported:
Command
+CBST
+CR
+CRC
+CRLP
+CSCS
+CEER
+CGMI
+CGMM
+CGMR
+CGSN
+CIMI
+CNUM
+CREG
+COPS
Timeout (Seconds)
0.2
0.2
0.2
0.2
0.2
20
20
20
180
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 35 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
+CLCK
+CPWD
+CLIP
+CLIR
+CCFC
+CCWA
+CHLD
+CUSD
+CAOC
+CSSN
+CLCC
+CPAS
+CPIN
+CSQ
+CPBS
+CPBR
+CPBF
+CPBW
+CALM
+CRSL
+CLVL
+CMUT
+CACM
+CAMM
+CPUC
+CMEE
+VTS
+GMI
+GMM
+GMR
+GSN
I3
I4
I5
+CSMS
+CPMS
+CMGF
+CSCA
+CSMP
+CSDH
+CSAS
+CRES
+CNMI
+CMGS
+CMSS
+CMGW
+CMGD
+CMGR
+CMGL
#CAP
180
180
180
180
180
20
20
180
20
20
20
20
20
20
20
20
20
20
20
20
20
180 / 5 for prompt">"
180
5 / 5 for prompt">"
10
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 36 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
#SRS
#SRP
#STM
#PCT
#SHDN
#QTEMP
#SGPO
#GGPI
#MONI
+CGACT
+CGATT
+CGDATA
+CGDCONT
+CGPADDR
+CGQMIN
+CGQREQ
10
10
10
10
10
10
10
10
10
180
180
20
20
20
20
20
5.2.4 Command issuing timing
The chain Command -> Response shall always be respected and a new command must not be issued before the
TRIZIUM has terminated all the sending of its response result code (whatever it may be).
This applies especially to applications that "sense" the OK text and therefore may send the next command before the
complete code OK is sent by the TRIZIUM.
It is advisable anyway to wait for at least 20ms between the end of the reception of the response and the issue of the
next AT command.
If the response codes are disabled and therefore the module does not report any response to the command, then at least
the 20ms pause time shall be respected.
During command mode, due to hardware limitations, under severe CPU load the serial port can loose some characters if
placed in autobauding at high speeds. Therefore if you encounter this problem fix the baud rate with AT+IPR
command.
5.2.5 Factory Profile and parameters stored in the profile
The TRIZIUM stores several command configurations in the internal non volatile memory (see command &W),
allowing to remember this status even after power off.
The parameters that are stored in the profile and their are:
GSM DATA MODE
: +CBST: 0,0,1
AUTOBAUD
: +IPR: 0
COMMAND ECHO
: E1
RESULT MESSAGES
: Q1
VERBOSE MESSAGES
: V1
EXTENDED MESSAGES
: X1
FLOW CONTROL OPTIONS
: &K3
CTS (C106) OPTIONS
: &B2
DSR (C107) OPTIONS
: &S3
DTR (C108) OPTIONS
: &D0
DCD (C109) OPTIONS
: &C1
RI (C125) OPTIONS
: \R1
C108/1 OPERATION
: &D4
POWER SAVING
: +CFUN: 1
DEFAULT PROFILE
: &Y0
S REGISTERS: S0=0;S1=0;S2=43;S3=13;S4=10;S5=8;S7=60;S12=50;S25=5;S38=20
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 37 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3 Hayes Compliant AT Commands
5.3.1 Generic Modem Control
5.3.1.1 &F - restore factory configuration
&F – restore factory configuration
Execute command
AT&F
Calls the factory configuration, resetting the default profile.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
5.3.1.2 Z - soft reset
Z – soft reset
Execute command
ATZ 
Send a software reset to device, loading on the configuration the specified default profile.
Parameter:  = 0…1 - profile
Note: Must be the last command on the line.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 38 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.3 +FCLASS - select active service class
+FCLASS - select active service class
Execute command
Read command
Returns the current configuration value of the parameter .
AT+FCLASS?
Write command
Set the TRIZIUM in specified connection mode (data, fax, voice), hence all the calls done
AT+FCLASS= 
after, will be data or voice.
Parameter:
:
:
:
Test command
AT+FCLASS=?
Example
Reference
SW release
0 = data
1 = fax class 1
8 = voice
Returns all supported values of the parameters .
GSM 07.07
Version A
5.3.1.4 &Y - designate a default reset profile
&Y – designate a default reset profile
Execute command
The TRIZIUM is able to store 2 complete configurations (see command &W). The
AT&Y 
command &Y defines which one of the 2 profiles will be the default profile to be loaded on
startup.
Parameter:  = 0…1 - profile
Note: Differently from ATZ command which simply loads the desired profile , with the
command AT&Y the chosen profile becomes the one which will be loaded on every startup.
Read command
Write command
Test command
Example
Reference
SW release
Version A
5.3.1.5 &W - store current configuration
&W – store current configuration
Execute command
Stores on profile n the complete configuration of the device.
AT&W 
Parameter:  = 0…1 - profile
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 39 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.6 &Z - store telephone number in the Telit TRIZIUM module internal
phonebook
&Z – store telephone number in the TRIZIUM internal phonebook
Execute command
The TRIZIUM has a built in non volatile memory in which telephone numbers of a
AT&Z  = 
maximum 24 digits can be stored. The command AT&Z  =  stores in the record n
the telephone number nr. The records cannot be overwritten, they must be cleared before
rewriting.
Parameter:
: phonebook record : telephone number
Note1: To delete the record  the command AT&Z= must be issued.
Note2: The records in the TRIZIUM memory can be viewed with the
command AT&N, while the telephone number stored in the record n can be
dialled by giving the command ATDS=.
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 40 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.7 &N - display internal phonebook stored numbers
&N – display internal phonebook stored numbers
Execute command
Returns the telephone number stored in the internal memory at the record number .
AT&N 
Parameter:  - phonebook record
Note: if parameter  is omitted then all the internal records are shown.
Read command
Write command
Test command
Example
Reference
SW release
Version A
5.3.1.8 +GMI - request manufacturer identification
+GMI – request manufacturer identification
Execute command
Returns the manufacturer identification.
AT+GMI
Read command
Write command
Test command
Example
Reference
SW release
V.25ter
Version A
5.3.1.9 +GMM - request model identification
+GMM – request model identification
Execute command
Returns the model identification.
AT+GMM
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.10
V.25ter
Version A
+GMR - request revision identification
+GMR – request revision identification
Execute command
Returns the software revision identification.
AT+GMR
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.11
V.25ter
Version A
+GCAP - request capabilities list
+GCAP – request capabilities list
Execute command
Returns the equipment supported command set list.
AT+GCAP
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 41 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.12
V.25ter
Version A
+GSN - request serial number
+GSN – request serial number
Execute command
Returns the device board serial number.
AT+GSN
Note: The number returned is not the IMSI, it is only the board number
Read command
Write command
Test command
Example
Reference
SW release
V.25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 42 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.13
&V - display current configuration & profile
&V – display current configuration & profile
Execute command
Returns all the configuration parameters settings.
AT&V
Read command
Write command
Test command
Example
AT&V
Reference
SW release
DTE SPEED
DTE FORMAT
CELLULAR PHONE
GSM DATA MODE
AUTOBAUD
COMMAND ECHO
RESULT MESSAGES
VERBOSE MESSAGES
EXTENDED MESSAGES
ECM TYPE MESSAGES
LINE SPEED
CONSTANT DTE SPEED
FLOW CONTROL OPTIONS
ERROR CORRECTION MODE
CTS (C106) OPTIONS
DSR (C107) OPTIONS
DTR (C108) OPTIONS
DCD (C109) OPTIONS
RI (C125) OPTIONS
C108/1 OPERATION
POWER SAVING ON DTR
CALL ABORT
DEFAULT PROFILE
OK
V25ter
Version A
5.3.1.14
: 19200
: 8N1
: GSM TELIT: Operative
: \N4=Not Trasparent
: +IPR0=YES
: E1=YES
: Q0=YES
: V1=YES
: X1=YES
: \V0=NO
: F8=9600
: \J0=YES
: &K3=HW bidirect.
: \N4=RLP
: &B2=OFF while disc.
: &S3=PHONE ready->ON
: &D0=ignored
: &C1=follows carrier
: \R1=OFF dur. off-hk
: &D4=NO
: +CFUN:1=NO
: YES
: &Y0=user profile 1
&V0 - display current configuration & profile
&V0 – display current configuration & profile
Execute command
Returns all the configuration parameters settings.
AT&V0
Note: this command is the same as &V, it is included only for backwards
compatibility.
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.15
Version A
&V1 - display S registers values
&V1 – display S registers values
Execute command
Returns the value of the S registers in decimal and hexadecimal value in the format:
AT&V1
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 43 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
REG DEC HEX
  
where
 - S register number (0 .. 52)
 - current value in decimal notation
 - current value in hexadecimal notation
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 44 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.16
&V2 - display last connection statistics
&V2 – display last connection statistics
Execute command
Returns the last connection statistics & connection failure reason.
AT&V2
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.17
Version A
\V - single line connect message
\V – Single line connect message
Execute command
Set single line connect message.
AT\V 
Parameter:
 = 0 - off
 = 1 on
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 45 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.1.18
%L - report line signal level
%L – report line signal level
Execute command
Reports the line signal level.
AT%L
Note: Since on mobile phone there's no line connection, command is included only for
compatibility and returns only OK.
To check signal strength (level) use the +CSQ command.
Read command
Write command
Test command
Example
Reference
SW release
5.3.1.19
Version A
%Q - report line quality
%Q – report line quality
Execute command
Reports the line quality indicator.
AT%Q
Note: Since on mobile phone there's no line connection, command is included only for
compatibility and returns only OK.
To check signal quality use the +CSQ command.
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 46 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2 DTE - modem interface control
5.3.2.1 E - command echo
E – command echo
Execute command
Read command
Write command
ATE 
Test command
Example
Reference
SW release
Controls the command echo response of the device, enabling or disabling the echo.
Parameter:
 = 0 - disables command echo, hence after this command the only characters received
by DTE are the responses to commands sent to device.
 = 1 - enables command echo (default) , hence command sent to the device are echoed
back to the DTE before the response is given.
V25ter
Version A
5.3.2.2 Q - quiet resut codes
Q – quiet result codes
Execute command
Read command
Write command
ATQ 
Test command
Example
Reference
SW release
Enables or disables the result codes.
Parameter:
 = 0 - enables result codes
 = 1 - disables result codes
Note: After disabling result codes with ATQ1, the device does not return a response to
commands (usually OK), but command are executed anyway.
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 47 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.3 V- result code form
V – result code form
Execute command
Read command
Write command
ATV 
Test command
Example
Reference
SW release
Sets the result code format.
Parameter:
 = 0 set the short format (terse) return codes are numbers 0-9.
 = 1 set the long form (verbose) return codes.
Note: Line feed is not issued before a short format result code.
V25ter
Version A
5.3.2.4 X - extended result codes
X – extended result codes
Execute command
Read command
Write command
ATX 
Test command
Note
Reference
SW release
Selects the result code messages subset used by the modem to inform the DTE of the result
of the commands.
Parameter:
 = 0 - send only OK, CONNECT, RING, NO CARRIER, ERROR, NO ANSWER
results. Busy tones reporting is disabled.
 = 1,2,3,4 - reports all messages (default).
For complete control on CONNECT response message see also +DR command.
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 48 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.5 I - Request identifier and software checksum
I – request identifier and software checksum
Execute command
Read command
Write command
ATI 
Test command
Example
Reference
SW release
Returns the identifier and a software checksum.
Parameter:
 = 0 numerical identifier.
 = 1 TRIZIUM checksum
 = 2 checksum check result
 = 3 manufacturer, software product code
 = 4 product name
 = 5 DOB version
V25ter
Version A
5.3.2.6 &C - data carrier detect (DCD) control
&C – Data carrier detect (DCD) control
Execute command
Read command
Write command
AT&C 
Test command
Example
Reference
SW release
Controls the RS232 DCD output behaviour.
Parameter:
 = 0 DCD remains high always.
 = 1 DCD follows the Carrier detect status: if carrier is detected DCD is high,
otherwise DCD is low. (default)
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 49 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.7 &D - data terminal ready (DTR) control
&D – data terminal ready (DTR) control
Execute command
Read command
Write command
AT&D 
Test command
Example
Reference
SW release
Controls the TRIZIUM behaviour to the RS232 DTR transitions.
Parameter:
 = 0 DTR transitions are ignored.
 = 1 when the TRIZIUM is connected, the high to low transition of DTR pin sets the
device in command mode, the current connection is NOT closed.
 = 2 when the TRIZIUM is connected , the high to low transition of DTR pin sets the
device in command mode and the current connection is closed.
Note: if AT&D2 command is issued, the device does not answer to incoming calls if DTR is
low, even if ATA command is given.
V25ter
Version A
5.3.2.8 &K - flow control
&K – flow control
Execute command
Read command
Write command
AT&K 
Test command
Example
Reference
SW release
Controls the RS232 flow control behaviour.
Parameter.
 = 0 - disabled
 = 1 - only CTS active, Hardware mono-directional
 = 2 - XON/XOFF software mono direction
 = 3 - RTS/CTS active, Hardware bi-directional (default)
 = 4 - XON/XOFF, Software bi-directional with filtering
 = 5 - XON/XOFF, Software bi-directional without filtering (Pass Through)
 = 6 - RTS/CTS active, Hardware bi-directional & software XON/XOFF (bidirectional) with filtering
Version A
5.3.2.9 &S - data set ready (DSR) control
&S – data set ready (DSR) control
Execute command
Read command
Write command
AT&S 
Controls the RS232 DSR pin behaviour:
n = 0 - always ON
n = 1 - follows the GSM traffic channel indication.
n = 2 - ON when connected
n = 3 - ON when device is ready to receive commands
Note: if option 1 is selected then DSR is tied up when the device receives from the network
the GSM traffic channel indication.
Test command
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 50 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Example
Reference
SW release
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 51 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.10
\R - ring (RI) control
\R – ring (RI) control
Execute command
Read command
Write command
AT\R 
controls the RING output pin behaviour.
Parameter:
 = 0 - RING on during ringing and further connection
 = 1 – RING on during ringing
 = 2 - RING follows the ring signal
Note: to check the ring option status use the &V command.
Test command
Example
Reference
SW release
5.3.2.11
Version A
+IPR - fixed DTE interface rate
+IPR – fixed DTE interface rate
Execute command
Read command
AT+IPR?
Write command
AT+IPR = 
Test command
AT+IPR=?
Example
Reference
SW release
5.3.2.12
Returns the current value of +IPR parameter.
Specifies the DTE speed at which the device accepts commands during command
mode operation, it may be used to fix the DTE-DCE interface speed.
Parameter:
 = 0/300/1200/2400/4800/9600/19200/38400/57600/115200
If  is unspecified or set to 0, then automatic speed detection is enabled and also
character format (see +ICF) is set to auto-detect.
If  is specified and not 0, DTE-DCE speed is fixed at that speed, hence no
speed auto-detection (autobauding) is enabled.
Returns the supported serial port speed list.
V25ter
Version A
+IFC - DTE - DTA flow control
+IFC – DTE-DTA flow control
Execute command
Read command
AT+IFC?
Write command
AT+IFC = , 
Returns active flow control settings.
Response
Selects the flow control behavior of the serial port in both directions: from DTE
to DTA ( option) and from DTA to DTE ()
Parameter:
 - flow control option for the data received by DTE,
 - flow control option for the data sent by DTA
 = 0 - flow control None
 = 1 - XON/XOFF filtered
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 52 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
Test command
AT+IFC=?
Example
Reference
SW release
 = 2 - C105 (RTS)
 = 3 - XON/XOFF not filtered
 = 0 - flow control None
 = 1 - XON/XOFF
 = 2 - C106 (CTS)
Note: This command is equivalent to &K command.
Response
Returns all supported values of the parameters  and .
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 53 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.13
+ILRR - DTE - modem rate reporting
+ILRR – DTE-modem rate reporting
Execute command
Read command
AT+ILRR?
Write command
AT+ILRR = 
Test command
AT+ILRR=?
Example
Reference
SW release
Returns active setting of port speed rate reporting information.
Controls whether or not the +ILRR: information text is transmitted from
the TRIZIUM to the DTE.
Parameter:
 = 0 - local port speed rate reporting disabled
 = 1 - local port speed rate reporting enabled
Note: this information if enabled is sent upon connection.
Returns all supported values of the parameter 
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 54 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.2.14
+ICF - DTE - modem character format
+ICF – DTE-modem character format
Execute command
Read command
AT+ICF?
Write command
AT+ICF = [,]
Test command
AT+ICF=?
Example
Reference
SW release
Returns current value of the character format.
Defines the asynchronous character format to be used when autobauding is
disabled.
Parameter:
 = 0..5, < parity> = 0/1
AT+ICF = 0 - auto detect
AT+ICF = 1 8N2
AT+ICF = 2,0 - 8O1
AT+ICF = 2,1 - 8E1
AT+ICF = 3 - 8N1
AT+ICF = 5,0 - 7O1
AT+ICF = 5,1 - 7E1
Note: the character format is defined as: number of bit per char, parity bit
and stop bit; where parity can be None, Odd and Even. E.g. 8E1 means 8 bit
per char with the even parity bit and 1 stop bit.
Returns all supported values of the parameters  and 
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 55 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.3 Call Control
5.3.3.1 D - dial
D – dial
Execute command
ATD 
ATD  ;
Starts a call to the phone number given as parameter.
Parameter:  - phone number to be dialled
Note: The call is a data call or voice call depending on +FCLASS setting. If AT+FCLASS=8
command was issued before calling then the call will be done as a voice call, instead if
AT+FCLASS=0 command was issued the call will be a data one. The default value of
+FCLASS is 0 hence calls are by default data ones.
The numbers accepted are 0-9 and *,#,”A”, ”B”, ”C”, ”D”,”+”.
For backwards compatibility with landline modems modifiers “T”, ”P”, ”R”, ”,”, ”W”, “!”,
“@” are accepted but have no effect.
Issues a VOICE call to the number given regardless of the current value of the parameter
+FCLASS, which remains unaffected.
Parameter:  - phone number to be dialled.
ATD  [;]
Issues a call (VOICE if ";" modifier is added to the end of the command) to the number
stored in the TRIZIUM internal phonebook position number .
Parameter:  - internal phonebook position to be called
ATD>  [;]
ATDL
ATDS=
ATD I [;]
Issues a call (VOICE if ";" modifier is added to the end of the command) to the number
stored in the SIM phonebook in the record number .
Parameter:  - SIM phonebook position to be called
Issues a call to the last number dialled.
Issues a call to the internally stored number at the position . ( See
commands &N and &Z)
Issues a call [voice if ; is added] overwriting the CLIR setting in order to hide the CLI to the
called party for the current call only.
ATD i [;]
Issues a call [voice if ; is added] overwriting the CLIR setting in order to show
the CLI to the called party for the current call only.
ATD G[;]
Issues a call [voice if ; is added] checking the CUG supplementary service for
ATDg[;]
the current call. Refer to +CCUG command.
ATD*[*]
perform whatever actions are necessary to establish communication between
[*[][*[]]]] the TE and the external PDN.
Parameters:
 - (GPRS Service Code) a digit string (value 99) which identifies
a request to use the GPRS
 - string that identifies the called party in the address space applicable
to the PDP.
: a string which indicates the layer 2 protocol to be used (see
+CGDATA command). For communications software that does not support
arbitrary characters in the dial string, the following numeric equivalents shall
be used:
1 - PPP
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 56 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
D – dial
Other values are reserved and will result in an ERROR response to the set
command.
: a digit string which specifies a particular PDP context definition (see
+CGDCONT command).
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 57 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.3.2 T - set tone dial
T – set tone dial
Execute command
ATT
It has no effect is included only for backward compatibility with landline modems.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
5.3.3.3 P - set pulse dial
P – set pulse dial
Execute command
ATP
It has no effect is included only for backward compatibility with landline modems.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
5.3.3.4 A - answer
A – answer
Execute command
ATA
It is used to answer to an incoming call if automatic answer is disabled.
Note: This command MUST be the last in the command line and must be followed
immediately by a  character.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
5.3.3.5 A/ - Last command automatic repetition
A/ – last command automatic repetition
Execute command
A/
It is used to execute again the last received command.
This command works only at fixed IPR.
Note: This command has been substituted with AT#/ command.
Refer to #/ command reference.
Read command
Write command
Test command
Example
Reference
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 58 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
SW release
Version A
5.3.3.6 H - disconnect
H - disconnect
Execute command
ATH
It is used to close the current conversation (voice, data or fax).
Note: When a data conversation is active the device is in on-line mode commands are not
sensed, instead characters are sent to the other interlocutor. To issue this command you
must be in command mode operation, hence escape sequence (see register S2) may be
required before issuing this command, otherwise if &D1 option is active, DTR pin should
be tied low to return in the command mode.
When a voice call is active, no escape sequence is needed.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 59 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.3.7 O - return to On Line Mode
O – return to on line mode
Execute command
ATO
It is used return to On-line mode from command mode. If there's no connection active
returns ERROR.
Note: After the issue of this command, if the device is in conversation, to send other
commands to the device you must return to command mode by issuing the escape sequence
or lowering DTR if &D1 option is active.
Read command
Write command
Test command
Example
Reference
SW release
V25ter.
Version A
5.3.3.8 &G - guard tone
&G – guard tone
Execute command
AT&G
It is has no effect is included only for backward compatibility with landline modems.
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 60 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.3.9 &P - pulse dial make/break ratio
&P – pulse dial make/break ratio
Execute command
AT&P
It is has no effect is included only for backward compatibility with landline modems..
Read command
Write command
Test command
Example
Reference
SW release
Version A
5.3.4 Modulation control
5.3.4.1 +MS - modulation control
+MS – modulation control
Execute command
Read command
Write command
AT+MS = , ,
, 
This command has no effect is included only for backward
compatibility with landline modems.
Parameter:
 =V21 / V22 / V22B / V23C / V32 / V34
 = 0/1
 = 0
 = 300-14400
Note: to change modulation requested use +CBST command.
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 61 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.4.2 %E - enable/disable line quality monitor and auto retrain or fallback /
fallforward
%E – enable/disable line quality monitor and auto retrain or fallback/fallforward
Execute command
It has no effect is included only for backward compatibility with
AT%E
landline modems.
Read command
Write command
Test command
Example
Reference
SW release
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 62 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.5 Compression control
5.3.5.1 +DS - set data compression
+DS – set data compression
Execute command
Read command
AT+DS?
Returns current value of the data compression parameter.
Write command
AT+DS = 
Sets the V42 compression parameter.
Parameter:
 = 0 - no compression
n> = 1 - compression enabled
Note: The only value supported is 0 - no compression
Test command
AT+DS=?
Example
Reference
SW release
Returns all supported values of the parameter n
V25ter
Version A
5.3.5.2 +DR - data compression reporting
+DR – data compression reporting
Execute command
Read command
Write command
AT+DR = 
Test command
Example
Reference
SW release
Controls the data compression reporting upon connection.
Parameter:
 = 0 no data compression reporting is displayed at the connection
 = 1 a data compression report message is sent by the device upon connection
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 63 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.6Break control
5.3.6.1 \B - transmit break to remote
\B – transmit break to remote
Execute command
Read command
Write command
AT\B
Test command
Example
Reference
SW release
It has no effect is included only for backward compatibility with landline
modems
Version A
5.3.6.2 \K - break handling
\K – break handling
Execute command
Read command
Write command
AT\K
Test command
Example
Reference
SW release
Response
It has no effect is included only for backward compatibility with landline
modems
 = 1.. 5
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 64 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.7 S parameters
5.3.7.1 S0 - number of rings to auto answer
S0 – number of rings to auto answer
Execute command
Read command
ATS0?
Write command
ATS0 = 
Test command
Example
Reference
SW release
Returns the current value of S0 parameter.
Sets the number of rings required before device automatically answers an
incoming call.
Parameter:
 = 0-255
 = 0 auto answer disabled
V25ter
Version A
5.3.7.2 S1 - ring counter
S1 – ring counter
Execute command
Read command
ATS1?
Write command
Test command
Example
Reference
SW release
S1 is incremented each time the device detects the ring signal of an incoming
call. S1is cleared if no ring occur over an eight seconds interval.
This command returns the value of this parameter.
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 65 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.7.3 S2 - escape character
S2 – escape character
Execute command
Read command
Write command
ATS2 = 
Test command
Example
Reference
SW release
S2 holds the decimal value of the ASCII character used as escape character.
This command sets this character equal to .
Parameter:  - escape character 0-255
Note: The escape sequence consists of three escape characters preceded by n
ms of idle and followed by m ms of idle.
Version A
5.3.7.4 S3 - carriage return character
S3 – carriage return character
Execute command
Read command
Write command
ATS3 = 
Test command
Example
Reference
SW release
Sets the command line and result code terminator character in decimal
ASCII.
Parameter:  - carriage return character 0-127
Note: Default 13 (Carriage Return)
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 66 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.7.5 S4 - line feed character
S4 – line feed character
Execute command
Read command
Write command
ATS4 = 
Test command
Example
Reference
SW release
Sets the character recognized as line feed character.
Parameter:  - line feed character 0-127
Note: Default 10 (Line Feed). The line feed character is output after carriage
return character if verbose result codes are used
( V1 option used ).
V25ter
Version A
5.3.7.6 S5 - backspace character
S5 – backspace character
Execute command
Read command
Write command
ATS5 = 
Test command
Example
Reference
SW release
Sets the decimal ASCII character that is recognized as backspace character.
Parameter:  - backspace character 1-127
Note: Default 8 ( backspace )
V25ter
Version A
Reproduction forbidden without DAI Telecom written authorization – All Right reserved – Right of modification reserved
page 67 of 202
Telit TRIZIUM Product Description
80264ST10007a Rev. 4– 09/09/04
5.3.7.7 S7 - wait time for carrier, silence or dial tone
S7 – wait time for carrier, silence or dial tone
Execute command
Read command
Write command
S7 sets the length of time in seconds that the device will wait for carrier before
ATS7 = 
hanging up the call. The timer is started when the device finishes dialing
(originate), or 2 seconds after going off-hook.
Parameter:  - 1-255
Note: Default is 60 seconds
Test command
Example
Reference
V25ter
SW release
Version A
5.3.7.8 S10 - lost carrier to hang up delay
S10 – lost carrier to hang up delay
Execute command
Read command
Write command
ATS10 = 

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Create Date                     : 2004:09:09 11:06:26Z
Modify Date                     : 2005:04:11 13:01:38+02:00
Page Count                      : 202
Creation Date                   : 2004:09:09 11:06:26Z
Author                          : DanieleLu
Producer                        : Acrobat PDFWriter 5.0 for Windows NT
Mod Date                        : 2004:09:09 11:09:47+03:00
Metadata Date                   : 2004:09:09 11:09:47+03:00
Title                           : 80264ST10007a_r3.doc
Creator                         : DanieleLu
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RI7TRIZIUM

Navigation menu