Teltronic U PTBSR75800B RF Transceiver / Base Station Repeater User Manual BSR BSR75 Installation Guide
Teltronic S.A.U. RF Transceiver / Base Station Repeater BSR BSR75 Installation Guide
User Manual
BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 TECHNICAL DESCRIPTION PowerTrunk-T BSR & BSR75. INSTALLATION GUIDE. Document Product Date en F067207PT_2800b05 PowerTrunk-T March 2018 Page 1 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 WASTE MANAGEMENT The symbol means that the product must be taken to separate collection at the product end-of life. Do not dispose of these products as unsorted municipal waste. PowerTrunk Inc. is the subsidiary of Teltronic S.A.U. responsible for business development, distribution and customer support for Teltronic’s Land Mobile Radio products in North America. The company is headquartered in New Jersey. Teltronic S.A.U. distributes the same products for Land Mobile Radio under different trademarks and brand names in other regions of the world. Disclaimer Although every reasonable effort has been made to ensure the accuracy of the information contained herein and in any other referred document, this should not be construed as a commitment on the part of Teltronic S.A.U. and/or PowerTrunk Inc., and the liability of Teltronic S.A.U. and/or PowerTrunk Inc. for any errors and omissions shall be limited to the correction of such errors and omissions. Teltronic S.A.U. and/or PowerTrunk Inc. welcomes any comment as a way to improve any delivered documentation. The information contained herein has been prepared for the use of appropriately trained personnel, and it is intended for the purpose of the agreement under which the information is submitted. Any party using or relying upon this information assumes full responsibility for such use and in no event shall Teltronic S.A.U. and/or PowerTrunk Inc. be liable to anyone for special, collateral, incidental, or consequential damages in connection with or arising out of the use of this information. The information or statements given in these documents regarding the suitability, capacity or performance of the mentioned hardware or software products cannot be considered binding but shall be defined in the agreement made between Teltronic S.A.U. and/or PowerTrunk Inc. and the customer. Teltronic S.A.U. and/or PowerTrunk Inc. reserves the right to revise these documents and to make changes to their content at any time, without prior notification. Copyright No part of the information contained herein and the other referred documents may be copied, distributed or transmitted by any means to any other party without prior written permission of Teltronic S.A.U. and/or PowerTrunk Inc. The distribution of this document may be also covered by NDA (non-disclosure agreement) between Teltronic S.A.U. and/or PowerTrunk Inc. and the receiver. Please also note that part of these contents even may be covered by patent rights. This document, the referred documents and the described product are considered protected by copyright according to the applicable laws. PowerTrunk and the PowerTrunk logo are registered trademarks of Teltronic S.A.U. Copyright © PowerTrunk Inc. All rights reserved en Page 2 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 TABLE OF CONTENTS 1. INTRODUCTION 2. UNPACKING AND CHECKING 3. PREVIOUS CONSIDERATIONS 4. INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY / INFORMATIONS SUR LA SÉCURITÉ ET LA COMPATIBILITÉ ÉLECTROMAGNÉTIQUE 4.1 4.1.1 4.1.2 4.1.3 4.1.4 4.1.5 4.2 4.2.1 4.2.2 4.2.3 4.2.4 4.2.5 ENGLISH GENERAL CONSIDERATIONS ABOUT SAFETY OPERATION AND EXPOSURE TO RF ENERGY IMPORTANT SAFETY NOTES ABOUT THE ANTENNA ELECTROMAGNETIC COMPATIBILITY REGULATORY INFORMATION (FCC AND ISED) EMC, SAFETY AND RF EXPOSURE STANDARDS FRANÇAIS 10 CONSIDÉRATIONS GÉNÉRALES SUR LA SÉCURITÉ FONCTIONNEMENT ET EXPOSITION À L'ÉNERGIE RF NOTES DE SÉCURITÉ SUR L'ANTENNE INFORMATIONS RÉGLEMENTAIRES SUR LA COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (FCC ET ISED) RÉGLEMENT SUR LA CEM, LA SÉCURITÉ ET L’ÉXPOSITION AUX RF 10 11 12 13 14 5. EQUIPMENT DESCRIPTION 15 5.1 5.2 5.3 5.4 15 17 18 21 FRONT VIEW REAR VIEW MODULES CABLING AND CONNECTORS 6. INSTALLATION GUIDE 23 6.1 6.2 6.3 6.4 23 23 24 24 LOCATION POWER SUPPLY CONNECTION ANTENNA CONNECTION SWITCHING ON THE BSR OR BSR75 7. CONFIGURATION 25 8. INCIDENTS 25 8.1 8.2 25 28 8.2.1 en ALARMS ALARMS WITHOUT STATUS LEDS INTERFERENCE AT BSR. 28 Page 3 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 1. INTRODUCTION The BSR module (Base Station Repeater 40 W) and BSR75 module (Base Station Repeater 75 W) are a modular design, high performance products used as TETRA repeaters. This manual is common to all the equipment models, including all their options and accessories. The proper functioning of any electronic device depends on its correct use. It is therefore recommended that the instructions in this manual be followed. 2. UNPACKING AND CHECKING The BSR or BSR75 module is usually supplied already assembled in the infrastructure cabinet; nevertheless, in special circumstances, it may be individually packaged. The equipment is supplied with all the modules already assembled in the rack and with RF cables connected. The modules in the basic configuration are: Control (RCPU), Transmitter (RTX or RTX75), power module (RPA or RPA75), Receiver (RRX) and the power supply module (RPS or RPS75). IMPORTANT: if any of these elements is missing or damaged, contact your dealer and / or installer. 3. PREVIOUS CONSIDERATIONS This manual contains information on instructions for installation, maintenance and use. Read the following pages before using this equipment. It is inadvisable to switch on the equipment without having previously connected the antenna or, in specific versions of BSR75, the 50W load to the TNC connector. Doing so may seriously damage the equipment and even cause irreparable damage to the transmitter circuits. It is important to use an antenna adjusted to the work frequency. en Page 4 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4. INFORMATION ON SAFETY AND ELECTROMAGNETIC COMPATIBILITY / INFORMATIONS SUR LA SÉCURITÉ ET LA COMPATIBILITÉ ÉLECTROMAGNÉTIQUE 4.1 ENGLISH 4.1.1 GENERAL CONSIDERATIONS ABOUT SAFETY Most electronic equipment is susceptible to electromagnetic interference if it is not duly protected. If the BSR or BSR75 is placed near unprotected electronic devices, they may malfunction. Only cables that fulfil the characteristics specified in this document must be used. Communication cables must be shielded and earthed at both ends. Do not attempt to dismantle this product. Servicing and repairs to this product must be performed by trained service technicians at PowerTrunk approved service centres. PowerTrunk has not approved any changes or modifications to this device by the user. Any changes or modifications could void the user’s authority to operate the equipment. Only fit an approved accessory. If a non-approved accessory is fitted, it may compromise the product safety ratings and may void any product warranty. Take care when handling the BSR or BSR75. It has sharp edges, which may cut if handled incorrectly. Maintenance and repair of these repeaters must be carried out by qualified personnel only. Connect the BSR or BSR75 chassis to earth. Switch off the BSR or BSR75 before inserting/removing any of its modules en Page 5 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.1.2 OPERATION AND EXPOSURE TO RF ENERGY It is the responsibility of the person operating the product to ensure that it is operated safely at all times, and that local laws and regulations governing the usage of Radio Frequency (RF) wireless devices are observed. Obey all signs and instructions relating to the usage to RF wireless devices. PowerTrunk designs and manufactures products to meet strict guidelines and international standards relating to Radio Frequency (RF) energy and the potential health risks associated with using RF wireless devices. If you have any concerns relating to long term health risks associated with using RF wireless devices, you should obtain advice from your employer. FCC and ISED radiation exposure statement This radio is intended for use in occupational/controlled applications where users have been made aware of the potential risks for exposure and can exercise control over their exposure. This product is not authorised for general population, consumer or similar use. This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. This equipment complies with FCC and ISED radiation exposure limits set forth for an uncontrolled environment. The antenna should be installed and operated with minimum distance of 5.5 m between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC compliance labelling on RF Exposure The following compliance product labelling can be found in a conspicuous location of the BSR75 for North America market: FCC notice on operating the device The device may contain functions that are not operational in U.S Territories except as noted in the certification filing. Devices may be restricted in frequency by the FCC TCB Grant. Please refer to it for allowed frequency ranges. The TCB Grant may have extended frequencies as noted in the certification filing and Section 2.927(b) may apply to the authorisation. The device complies with 47 CFR Part 90.203 (e), in that the operator cannot directly program the transmit frequencies using the normal accessible external controls. All instructions detailed in this manual must be followed in order to ensure compliance with RF exposure limits. Failure to observe these restrictions may result in exceeding the FCC RF exposure limits. ISED Canada information on RF Exposure The Government of Canada provides further information about RF Exposure by means of official publications that are available on the following website: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01904.html en Page 6 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.1.3 IMPORTANT SAFETY NOTES ABOUT THE ANTENNA The BSR75 has been approved by FCC and ISED to operate with the antenna types listed below with the maximum permissible gain indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. MODEL CERTIFICATION NUMBER BSR75 –7 (409-430 MHz) FCC ID: WT7PTBSR75410B IC: 8624A-PTBSR75410B MODEL BSR75 –8 (450-470 MHz) CERTIFICATION NUMBER FCC ID: WT7PTBSR75450B IC: 8624A-PTBSR75450B MODEL CERTIFICATION NUMBER BSR75 –K (763-806 MHz) FCC ID: WT7PTBSR75760B IC: 8624A-PTBSR75760B MODEL CERTIFICATION NUMBER BSR75 –N (806-870 MHz) FCC ID: IC: WT7PTBSR75800B 8624A-PTBSR75800B TYPE OF ANTENNA MAX.GAIN Vertically polarised panel antenna 11.0 dBi Cross-polarised panel antenna 15.0 dBi Vertically polarised collinear antenna 11.15 dBi TYPE OF ANTENNA MAX.GAIN Vertically polarised panel antenna 11.0 dBi Cross-polarised panel antenna 15.0 dBi Vertically polarised collinear antenna 11.15 dBi TYPE OF ANTENNA MAX.GAIN Vertically polarised panel antenna 16.5 dBi Cross-polarised panel antenna 18.0 dBi Vertically polarised collinear antenna 11.15 dBi TYPE OF ANTENNA MAX.GAIN Vertically polarised panel antenna 16.5 dBi Cross-polarised panel antenna 18.0 dBi Vertically polarised collinear antenna 11.15 dBi Only use PowerTrunk approved antennas with this product. The use of non-approved antennas may damage the product, will result in the non-compliance with regulatory requirements, will compromise the product safety ratings, will reduce the length of operating time and will invalidate the product warranty. When installing the antenna, follow the guidelines for exposure of the human body to high and low frequency electromagnetic fields. Follow the supplier’s / manufacturer’s instructions. The BSR must not transmit without its antenna connected or, in specific versions of BSR75, without the 50W load in the TNC connector. Burns may be suffered if the antenna connector output of the power module (RPA or RPA75) is touched by bare skin when the BSR or BSR75 are transmitting with the antenna disconnected. NEVER use your device if the antenna shows signs of damage. en Page 7 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.1.4 ELECTROMAGNETIC COMPATIBILITY REGULATORY INFORMATION (FCC AND ISED) These devices generate, use and radiate RF energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. FCC interference statement and compliance labelling This device complies with Part 15 of the FCC Rules and Industry Canada’s licence-exempt RSS standards. Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. A label with the text above can be found in a conspicuous location of the BSR75 for North America market. FCC Class B digital device notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. ISED Canada ICES-003 compliance labelling This Class B digital apparatus has been fully tested and found to comply with the Canadian ISED (Innovation, Science and Economic Development) standard ICES-003. A label with the text below can be found in a prominent location of the radio for North America market: CAN ICES-3 (B) / NMB-3 (B) en Page 8 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.1.5 EMC, SAFETY AND RF EXPOSURE STANDARDS BSR and BSR75 are in conformity with the applicable requirements of the following standards and normative documents, in full accordance with the aforesaid directive: ETSI EN 300 394-1 Terrestrial Trunked Radio (TETRA);Conformance testing specification; Part 1: Radio ETSI EN 301 489-1 Electromagnetic Compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements ETSI EN 301 489-5 ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 5: Specific conditions for Private land Mobile Radio (PMR) and ancillary equipment (speech and non-speech) and Terrestrial Trunked Radio (TETRA) Harmonised Standard covering the essential requirements of article 3.1(b) of the Directive 2014/53/EU EN 60950-1 / IEC 60950-1 / UL 60950-1 Information technology equipment - Safety -- Part 1: General requirements EN 50385 Product standard to demonstrate the compliance of radio base stations and fixed terminal stations for wireless telecommunication systems with the basic restrictions or the reference levels related to human exposure to radio frequency electromagnetic fields (110 MHz - 40 GHz) - General public BSR and BSR75 have been designed according to the Radio Equipment Directive 2014/53/EU (RED). Note: The exact editions can be found in the declaration of conformity. en Page 9 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.2 FRANÇAIS 4.2.1 CONSIDÉRATIONS GÉNÉRALES SUR LA SÉCURITÉ La plupart des équipements électroniques sont susceptibles d'être soumis à des interférences électromagnétiques s'ils ne sont pas correctement protégés. Le montage de le BSR ou le BSR75 est placé à proximité d'équipements électroniques non protégés peut provoquer un dysfonctionnement de ces derniers. Seuls les câbles répondant aux caractéristiques indiquées dans ce document doivent être utilisés. Les câbles de communication doivent être blindés et ils doivent être mis à la terre aux deux extrémit N'essayez pas de démonter ce produit. L'entretien et les réparations de ce produit doivent être effectués par des techniciens de maintenance qualifiés dans les centres de service agréés par PowerTrunk. PowerTrunk n’approuve aucune modification apportée à l’appareil par l’utilisateur, quelle qu’en soit la nature. Tout changement ou modification peuvent annuler le droit d’utilisation de l’appareil par l’utilisateur. N'installez qu'un accessoire approuvé. Si un accessoire non approuvé est installé, cela pourrait compromettre les cotes de sécurité du produit et annuler la garantie du produit Manipuler le BST/BSR75 avec soin. Cet équipement est pourvu d'arêtes qui peuvent être à l'origine de coupures en cas de mauvaise manipulation. La maintenance et la réparation de cet équipement doivent être prises en charge par du personnel qualifié. Connectez le châssis BSR ou BSR75 à la terre. Eteindre le BSR ou le BSR75 avant d'insérer / retirer l'un de ses modules en Page 10 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.2.2 FONCTIONNEMENT ET EXPOSITION À L'ÉNERGIE RF Il est de la responsabilité de la personne qui exploite le produit de s'assurer qu'il est exploité en toute sécurité en tout temps et que les lois et règlements régissant l'utilisation des appareils sans fil à radiofréquence (RF) sont respectés. Respectez tous les signes et instructions relatifs à l'utilisation des appareils RF sans fil Powertrunk conçoit et fabrique des produits répondant aux normes et directives internationales strictes relatives à l'énergie des radiofréquences (RF) et aux risques potentiels pour la santé associés à l'utilisation de dispositifs RF sans fil. Si vous avez des préoccupations concernant les risques à long terme pour la santé associés à l'utilisation de dispositifs RF sans fil, vous devriez obtenir des conseils de votre employeur Déclaration de l'exposition aux radiations FCC et ISED Cette radio est conçue pour être utilisée dans des applications professionnelles / contrôlées où les utilisateurs ont été informés des risques potentiels d'une exposition et peuvent exercer un contrôle sur leur exposition. Ce produit n'est pas autorisé pour l'usage de la population générale, consommateur ou similaire. Cet émetteur ne doit pas être localisé ou utilisé avec d'autres antennes ou émetteurs. Cet équipement est conforme aux limites d'exposition aux radiations FCC et ISED définies pour un environnement non contrôlé. L'antenne doit être installée de façon à garder une distance minimale de 5.5 m entre la source de rayonnements et votre corps. L'émetteur ne doit pas être colocalisé ni fonctionner conjointement avec à autre antenne ou autre émetteur. Étiquetage de conformité FCC RF L'étiquette de conformité de produit suivante peut être trouvée dans un emplacement visible sur l'unité BSR75 pour le marché nord-américain: Avis sur le fonctionnement du dispositif FCC L'appareil peut contenir des fonctions qui ne sont pas opérationnelles dans les territoires des ÉtatsUnis. UU sauf tel qu'indiqué dans la demande de certification. La subvention FCC TCB peut limiter la fréquence des appareils. Voir les plages de fréquences autorisées. La subvention de TCB peut avoir des fréquences étendues comme indiqué dans la soumission de certification et la section 2.927 (b) peut s'appliquer à l'autorisation. L'appareil est conforme à la norme 47 CFR Part 90.203 (e), car l'opérateur ne peut pas programmer directement les fréquences de transmission à l'aide des commandes externes normalement accessibles. Toutes les instructions détaillées dans ce manuel doivent être suivies pour assurer la conformité aux limites d'exposition RF. Information d'ISED Canada sur l'exposition aux RF Le gouvernement du Canada fournit plus de renseignements sur l'exposition aux radiofréquences au moyen de publications officielles disponibles sur le site Web suivant: http://www.ic.gc.ca/eic/site/smt-gst.nsf/eng/sf01904.html en Page 11 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.2.3 NOTES DE SÉCURITÉ SUR L'ANTENNE BSR75 a été approuvée par FCC et ISED pour fonctionner avec les types d'antennes énumérés cidessous avec le gain maximum admissible indiqué. Les types d'antennes non inclus dans cette liste, qui ont un gain supérieur au gain maximal indiqué pour ce type, sont strictement interdits pour une utilisation avec cet appareil MODÉLE NUMÉRO DE CERTIFICATION TYPE D'ANTENNE Antenne de verticalement BSR75 –7 (409-430 MHz) FCC ID: WT7PTBSR75410B IC: 8624A-PTBSR75410B BSR75 –8 (450-470 MHz) MODÉLE BSR75 –K (763-806 MHz) MODÉLE BSR75 –N (806-870 MHz) NUMÉRO DE CERTIFICATION FCC ID: WT7PTBSR75450B IC: 8624A-PTBSR75450B NUMÉRO DE CERTIFICATION FCC ID: WT7PTBSR75760B IC: 8624A-PTBSR75760B NUMÉRO DE CERTIFICATION FCC ID: IC: WT7PTBSR75800B 8624A-PTBSR75800B polarisée Cross-polarised panel antenna Antenne de verticalement MODÉLE MAX.GAIN panneau panneau 11.0 dBi 15.0 dBi polarisée TYPE D'ANTENNE Antenne de panneau polarisée verticalement Antenne de panneau à polarisation croisée Antenne de panneau polarisée verticalement TYPE D'ANTENNE Antenne de panneau polarisée verticalement Antenne de panneau à polarisation croisée Antenne de panneau polarisée verticalement TYPE D'ANTENNE Antenne de panneau polarisée verticalement Antenne de panneau à polarisation croisée Antenne de panneau polarisée verticalement 11.15 dBi MAX.GAIN 11.0 dBi 15.0 dBi 11.15 dBi MAX.GAIN 16.5 dBi 18.0 dBi 11.15 dBi MAX.GAIN 16.5 dBi 18.0 dBi 11.15 dBi Utilisez uniquement des antennes approuvées par Powertrunk avec ce produit. L'utilisation d'antennes non approuvées peut endommager le produit, entraîner le non-respect des exigences réglementaires, compromettre les cotes de sécurité du produit, réduire le temps de fonctionnement et invalider la garantie du produit. Une fois l'antenne installée, suivez les directives pour exposer le corps humain aux champs électromagnétiques de haute et basse fréquence. Suivez les instructions du fournisseur / fabricant. N'utilisez JAMAIS votre appareil sans antenne connectée ou, dans des versions spécifiques de BSR75, sans la charge de 50W dans le connecteur TNC. Des brûlures peuvent être subies si la sortie du connecteur d'antenne du module d'alimentation (RPA ou RPA75) est touchée par la peau nue lorsque le BSR ou le BSR75 émet avec l'antenne déconnectée. N'utilisez JAMAIS votre appareil si l'antenne présente des signes de dommages en Page 12 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.2.4 INFORMATIONS RÉGLEMENTAIRES SUR LA COMPATIBILITÉ ÉLECTROMAGNÉTIQUE (FCC ET ISED) Ces appareils génèrent, utilisent et rayonnent de l'énergie RF et, s'ils ne sont pas installés et utilisés conformément au manuel d'instructions, peuvent causer des interférences nuisibles aux communications radio. Déclaration d'interférence et étiquetage de conformité FCC Cet appareil est conforme à la partie 15 des règlements de la FCC et aux règles RSS exemptées de la licence d'Industrie Canada. Le fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas causer d'interférences, et (2) cet appareil doit accepter toute interférence, y compris les interférences pouvant provoquer un fonctionnement indésirable de l'appareil. Une étiquette avec le texte ci-dessus peut être trouvée dans un endroit visible de le BSR75 pour le marché nord-américain. Avis sur les appareils numériques de classe B de la FCC Cet équipement a été testé et répond aux limites d'un appareil numérique de classe B, conformément à la partie 15 des règles de la FCC. Ces limites sont conçues pour fournir une protection raisonnable contre les interférences nuisibles dans une installation résidentielle. Cet équipement génère, utilise et peut émettre de l'énergie radiofréquence et, s'il n'est pas installé et utilisé conformément aux instructions, peut causer des interférences nuisibles aux communications radio. Cependant, il n'y a aucune garantie que des interférences ne se produiront pas dans une installation particulière. Si cet équipement cause des interférences nuisibles à la réception radio ou télévision, ce qui peut être déterminé en éteignant et en rallumant l'équipement, l'utilisateur est encouragé à essayer de corriger l'interférence par une ou plusieurs des mesures suivantes: - Réorienter ou déplacer l'antenne de réception. - Augmentez la distance entre l'équipement et le récepteur. - Connectez l'équipement à une prise d'un circuit différent de celui auquel le récepteur est connecté. - Consulter le revendeur ou un technicien radio / TV expérimenté pour obtenir de l'aide. Étiquetage de conformité ISED Canada ICES-003 Cet appareil numérique de classe B a été entièrement testé et est conforme à la norme canadienne ISED (Innovation, Sciences et Développement Économique) ICES-003. Une étiquette avec le texte suivant peut être trouvée dans un endroit visible sur la radio pour le marché nord-américain: CAN ICES-3 (B) / NMB-3 (B) en Page 13 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.2.5 RÉGLEMENT SUR LA CEM, LA SÉCURITÉ ET L’ÉXPOSITION AUX RF L'équipement a été conçu conformément aux réglementations suivantes: ETSI EN 300 394-1 ETSI EN 301 489-1 ETSI EN 301 489-5 Réseaux radioélectriques à ressources partagées (TETRA); spécification du test de conformité ; Partie 1: Radio Compatibilité électromagnétique et spectre radioélectrique (ERM); norme de compatibilité électromagnétique (CEM) pour l'équipement et les services radio ; Partie 1: Conditions requises techniques courantes Compatibilité électromagnétique (EMC) pour les équipements et services radio; Part. 5: Conditions spécifiques pour la norme harmonisée de radio mobile terrestre privée (PMR) et de matériel auxiliaire (parole et non-parole) et radio terrestre à ressources partagées (TETRA) couvrant les exigences essentielles de l'article 3.1 (b) de la directive 2014/53 / UE EN 60950-1 / IEC 60950-1 / UL 60950-1 Équipement de technologie d'informations - Sécurité -- Partie 1: Exigences générales EN 50385 Norme produit pour la démonstration de la conformité des stations de base radio et des stations terminales fixes pour les radio télécommunications, aux restrictions de base et aux niveaux de référence relatifs à l'exposition de l'homme aux champs électromagnétiques (110 MHz - 40 GHz) - Application au public en général BSR et BSR75 ont été conçus conformément à la directive sur les équipements radio 2014/53 / UE (RED). Note: Les éditions exactes peuvent être trouvées dans la déclaration de conformité. en Page 14 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 5. EQUIPMENT DESCRIPTION 5.1 FRONT VIEW ¨ BSR 1.- RPS (Repeater Power Supply) 2.- RPA (Repeater Power Amplifier) 3.- RTX (Repeater Transmitter) 4.- RRX (Repeater Receiver) 5.- Option RRX2/BSYNC (Repeater Receiver 2 / BSR Synchronism) 6.- RCPU (Repeater Control Processing Unit) 7.- Switch ON/OFF en Page 15 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 ¨ BSR75 1.- RPS75 (Repeater Power Supply 75 W) 2.- RPA75 (Repeater Power Amplifier 75 W) 3.- RTX75 (Repeater Transmitter 75 W) 4.- RRX (Repeater Receiver) 5.- Option RRX2/BSYNC ( Repeater Receiver 2 / BSR Synchronism) 6.- RCPU (Repeater Control Processing Unit) 7.- Switch ON/OFF en Page 16 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 5.2 ¨ ¨ en REAR VIEW BSR 17 18 19 20 16 15 14 17 18 19 20 16 15 14 21 13 23 22 12 11 24 10 10 BSR75 21 13 22 23 12 24 11 25 Page 17 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 5.3 MODULES 1.- RPS or RPS75 (REPEATER POWER SUPPLY) LEDs to indicate module status. LED SUPPLY TYPE Green NORMAL STATUS On 24 V or 26.4 V Green On 13.2 V Green On FUNCTIÓN There are 27.4 V at the RPS or RPS75 input There are 27.4 V at the RPS or RPS75 output There are 13.2 V at the RPS or RPS 75 output Power on switch (Ref. 7): ON/OFF switch to connect to and disconnect from the BSR or BSR75. 2.- RPA or RPA75 (REPEATER POWER AMPLIFIER) LEDs to indicate module status: LED ON TX POWER TYPE Green Green NORMAL STATUS On On FUNCTIÓN Power supply correct Module transmitting 3.- RTX or RTX75 (REPEATER TRANSMITTER) LEDs to indicate module status: en LED ON TYPE Green NORMAL STATUS On FUNCTIÓN Power supply correct REF. ERROR Red Off Failure in the 10 MHz reference INT. ERROR Red Off Internal failure BBSR ERROR Red Off RPA ERROR Red Off Communication failure with RCPU module RPA or RPA75 failure RPW ERROR Red Off Reflected power failure Page 18 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 4.- RRX (REPEATER RECEIVER) LEDs to indicate module status: ON LED TYPE Green NORMAL STATUS FUNCTIÓN On Power supply correct REF. ERROR Red Off Failure in the 10 MHz reference INT. ERROR Red Off Internal failure BBSR ERROR Red Off Communication failure with the RCPU module 5.- SLOT OPTION: RRX2 / BSYNC (REPEATER RECEIVER 2/ BSR SYNCHRONISM) LEDs to indicate the status of option RRX2: LED ON TYPE Green NORMAL STATUS FUNCTIÓN On Power supply correct REF. ERROR Red Off Failure in the 10 MHz reference INT. ERROR Red Off Internal failure BBSR ERROR Red Off Communication module failure with RCPU LEDs to indicate the status of option BSYNC: LED ON REF. ERROR WARM UP TIME GPS PPS GPS TIME LOCAL PPS LOCAL TYPE Green Red Red Green Green Green Green NORMAL STATUS On Off Off Flashing Flashing Flashing Flashing FUNCTIÓN Power supply correct Failure in the 10 MHz reference Oscillator in warming up phase There is NMEA signal from GPS There is PPS signal from GPS There is NMEA local signal (without GPS) There is PPS local signal (without GPS) NOTE: this slot is not used in the BSR basic configuration. en Page 19 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 6.- RCPU (REPEATER CONTROL) LEDs to indicate the module status: en LED ON REF. ERROR INT. ERROR BBSR ERROR DIV ERROR TYPE Green Red Red Red Red NORMAL STATUS On Off Off Off Off FUNCTIÓN Power supply correct Failure in the 10 MHz reference Internal failure BSR bus failure Diversity failure CNC ERROR AUX MCCH RX TX ETH LINK1 Red Green Green Green Green Yellow Off Off Off / On Flickering On On ETH LINK2 Yellow Off ETH RX ETH TX Green Green Flashing Flashing Communication failure with the CNC Not used Main carrier indicator TETRA information received TETRA information transmission Link between the local network switch and the RCPU module in Ethernet port 1 Link between the local network switch and the RCPU module in Ethernet port 1 Reception of an Ethernet packet Transmission of an Ethernet packet Page 20 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 5.4 ¨ CABLING AND CONNECTORS BSR 8.- Power supply connector. 9.- Transmitter antenna connector. 10.- SMB RF cables. 11.- Reception antenna connector (receiver chain 1). 12.- Reception antenna connector (receiver chain 2). 13.- Reception antenna connectors for the RRX2 option / antenna connectors for the GPS, depending on the inserted module. 14.- Ethernet_A connector. 15.- Ethernet_B connector. 16.- SYNC_OUT_2 connector. 17.- SYNC_OUT_1 connector. 18.- SYNC_IN_1 connector. 19.- SYNC_IN_2 connector. 20.- Maintenance connector for BSR Bus. 21.- VT100 Connector for RCPU module maintenance. 22.- VT100 Connector for RRX2 module maintenance. 23.- VT100 Connector for RRX1 module maintenance. 24.- VT100 Connector for RTX module maintenance. en Page 21 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 ¨ BSR75 8.- Power supply connector. 9.- Transmission power antenna connector. 10.- SMB RF cables. 11.- Reception antenna connector (receiver chain 1). 12.- Reception antenna connector (receiver chain 2). 13.- Reception antenna connectors for the RRX2 option / antenna connectors for the GPS, depending on the inserted module. 14.- Ethernet_A connector. 15.- Ethernet_B connector. 16.- SYNC_OUT_2 connector. 17.- SYNC_OUT_1 connector. 18.- SYNC_IN_1 connector. 19.- SYNC_IN_2 connector. 20.- Maintenance connector for BSR bus. 21.- Connector VT100 for RCPU module maintenance. 22.- Connector VT100 for RRX2 module maintenance. 23.- Connector VT100 for RRX1 module maintenance. 24.- Connector VT100 for RTX75 module maintenance. 25.- TNC connector for 50W load (only in specific BSR75 hardware versions). en Page 22 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 6. INSTALLATION GUIDE The following recommendations must be followed closely before starting up the BSR module or the BSR75 module. 6.1 LOCATION The BSR and BSR75 have been designed in the standard format of 19” / 3 units high, and so they must be installed in cabinets with this format. The BSR or BSR75 site must be permanent, well-ventilated and without vibrations. 6.2 POWER SUPPLY CONNECTION DC power supply: check that the power supply source and/or the battery to be used meet the voltage and current requirements necessary to supply the equipment: Nominal voltage: 27.4 VDC (range: from 21.6 to 28 VDC) Minimum source current: 10 A (BSR) or 20 A (BSR75) If lead batteries are used, they are to be placed as far from the BSR or BSR75 as possible to prevent corrosion in the repeater due to battery vapours. They should be situated in a wellventilated place. Use the power supply connector provided (D013000) to connect the BSR or BSR75 to the power supply source. Use cable with a minimum section of 3.5 mm (or AWG-12). Ensure that the connection is made with the correct polarity. Ensure that the earth connection is made. Make this connection with a cable of maximum diameter and minimum length. NEVER use a gas or electricity conduit as an earth. en Page 23 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 6.3 ANTENNA CONNECTION Choose the most adaptable antenna for the installation. The antenna must have an impedance of 50 ohms to the equipment transmission frequency. Install the antenna in accordance with the manufacturer’s instructions. Use cable coaxial, avoiding as much as possible large cable lengths. Cable impedance is 50 ohms. Measure the ROE of the installation. Never accept a ROE greater than 2. If a duplexer module or a band pass filter is required, adjust them to the work frequency before starting up. 6.4 SWITCHING ON THE BSR OR BSR75 Check the connections between the modules. Check that the power supply source is connected correctly. Check that the RF SMB cables are connected correctly (see Rear View diagram Ref. 10). Check the connections of the antennas in the RPA or RPA75 and RRX modules. Only in case of the BSR75 check the 50W load is connected to the rear TNC connector in the RPA75. Check that the Ethernet connections to the CNC/Gateway are in accordance with the configuration. Check that the RPS or RPS75 module LED SUPPLY is on. Activate the power on switch on the RPS module or RPS75 module. Check that the 24V LED and the 13.2 V LED on the RPS module or the 26.4 V LED and 13.2 V LED on the RPS75 module are on and check that the LEDS ON are switched on for the other modules. Wait for the BSR or BSR75 to start up. Check that the mobile equipment is registered in the BSR or BSR75. Note: see section 5 for more information on references for the different modules and LEDs. en Page 24 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 7. CONFIGURATION A BSR (BSR or BSR75) is configured via a NMS (Network Management System). To configure the BSR or BSR75, consult NMS User manual. 8. INCIDENTS The repeater must be repaired by authorized technical personnel only. If a BSR failure occurs, the entire BSR must be replaced. If transmitter module is damaged and there is not an entire BSR available to replace, set RTX and RPA modules previously calibrated jointly. If an error or alarm occurs in the BSR or BSR75, this is indicated in the corresponding LED for each one of the modules. The following list shows the possible failures and their solutions. 8.1 ALARMS RPA / RPA75 RPS / RPS75 Led indication SUPPLY en 24V or 26.4 V 13.2 V Status Failure / Solution OFF Power supply failure. Check that the source and the power supply cable are correctly connected. Check the internal fuse of the RPS. Contact Technical Services if unsolved. OFF Power supply failure. Contact Technical services. OFF Power supply failure. Contact Technical services. ON OFF Power supply failure. Contact Technical Services. TX POWER OFF No power transmission in the antenna. Wait for BSR or BSR75 to be started up by the CNC. Check other LED indications. Contact Technical Services if unsolved. Page 25 of 28 ON REF. ERROR INT. ERROR BBSR ERROR OFF ON ON ON RPA ERROR ON RPW ERROR ON ON REF. ERROR INT. ERROR BBSR ERROR OFF ON ON ON Internal power supply failure. Contact Technical services. Failure in the 10 MHz reference. Contact Technical services. Internal failure. Contact Technical services. Communication failure with the RCPU module. Check that all the modules are correctly installed. Contact Technical Services if still unsolved. ON REF. ERROR TIME GPS OFF OFF OFF PPS GPS OFF TIME LOCAL OFF PPS LOCAL OFF Internal power supply failure. Contact Technical services. Failure in the 10 MHz reference. Contact Technical services. If GPS is activated, there is failure in the data frame. Contact Technical Services. If GPS is activated, there is failure in the PPS signal of the GPS: - Check that the starting up period has been exceeded (about 10 minutes after switching on) - Check the GPS antenna connection. - Check the correct positioning of the GPS antenna, in accordance with the manufacturer’s instructions. Contact Technical Services if still unsolved. If GPS is not activated, there is failure in the local reference data frame. Contact Technical Services. If GPS is not activated, there is failure in the local PPS signal. Contact Technical Services. BSYNC RRX RTX / RTX75 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 en Internal power supply failure. Contact Technical services. Failure in the 10 MHz reference. Contact Technical services. Internal failure. Contact Technical services. Communication failure with the RCPU module. Check that all the modules are correctly installed. Contact Technical services if still unsolved. Failure in the RPA or RPA75 modules. Check that the RF SMB cables (Ref. 10) are correctly connected. Contact Technical services i still unsolved. Reflected power alarm. Check that the antenna is correctly installed. Contact Technical services. Page 26 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 OFF ON INT ERROR BBSR ERROR ON ON DIV ERROR ON CNC ERROR ON RX Continuous ON ETH LINK1 OFF ETH LINK2 OFF ETH RX OFF ETH TX OFF RCPU ON REF ERROR en Internal power supply failure. Contact Technical Services. Failure in the 10 MHz reference. Check that the BSYNC module is installed or that the SYNC IN cable is correctly connected. Contact Technical services if still unsolved. Internal failure. Contact Technical Services. Communication failure by the BSR bus. Check that all the modules are correctly installed. Contact Technical services if still unsolved. Error in diversity: occurs when the difference in received power between received paths exceeds a level (20 dBs by default) for a consecutive number of receptions. These receptions on the received paths which do not have sufficient power are not counted. This alarm does not disappear until there are no receptions with the sufficient power, and until the difference of received power between received paths does not exceed the level previously mentioned. Check diversity configuration in the CNC. Check that the reception antennas are correctly installed. Contact Technical services if still unsolved. Communication failure with the CNC. Check the Ethernet connections. Check that the CNC is working correctly. Contact Technical Services if still unsolved. Interference detection. Check the installation. Check that the work frequencies are correct. Failure in Ethernet link 1. Check Ethernet connection 1 and the Switch A. Failure in Ethernet link 2. Check Ethernet connection 2 and the Switch B. Packets are not received by Ethernet. Check the Ethernet connections. Packets are not sent by Ethernet. Check the Ethernet connections. Page 27 of 28 BSR & BSR75. INSTALLATION GUIDE. F067207PT_2800b05 8.2 ALARMS WITHOUT STATUS LEDS 8.2.1 INTERFERENCE AT BSR. This alarm is monitored in the management and configuration module NMS. See the infrastructure Event List in the NMS Client Help contents. Interference in the BSR or BSR75 is activated when there are a large number of consecutive reception faults in the BSR or BSR75. A reception fault is considered when a level higher than the threshold for reception of the carrier, but is not recognized as valid TETRA signal. Depending on the signal level, interference is considered low or high. So, if the level of signal is above the threshold for reception and below the threshold set to high interference and is not recognized as valid sign, it will be a low interference alarm. If the signal level is above the threshold set to high interference and is not recognized as a valid signal, the low level alarm would disappear (if it happened) and high interference would produce. These alarms are turned off when the interference source disappears or with any right TETRA reception for low interference case, and with more than one consecutive right reception for high-level interference. en Page 28 of 28
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Producer : PDF-XChange Printer 2012 (5.0 build 271 271) [271Windows 7 Professional x64 (Build 7601: Service Pack 1)] Title : BSR & BSR75. Installation Guide. Subject : PowerTrunk-T TECHNICAL MANUAL Author : PowerTrunk Inc. Keywords : PowerTrunk-T Creator : PDF-XChange Office Addin Create Date : 2018:03:07 17:37:52+01:00 Page Layout : SinglePage Page Count : 28EXIF Metadata provided by EXIF.tools