Model 417 Users Manual
TABLE OF CONTENTS TABLE OF CONTENTS LIST OF ILLUSTRATIONS SPECIFICATIONS WARNING NOTICES 10 METER OPERATION INTRODUCTION UNPACKING i-ii iii-iv v-vi vii vii viii ix 1 INSTALLATION 1.1 1.2 1.3 1-1 1-1 INTRODUCTION ELECTRICAL CONNECTIONS HIGH VOLTAGE TRANSFORMER INSTALLATION TRANSCEIVER INTERCONNECTIONS ANTENNA REQUIREMENTS GROUND CONNECTION HIGH POWER OPERATION ALC COOLING SYSTEM 1.4 1.5 1.6 1.7 1.8 1.9 1-1 1-2 1-2 1-2 1-2 1-3 1-3 2-1 2 OPERATING INSTRUC TIONS 2.1 2.2 INTRODUCTION FRONT PANEL CONTROLS 2.2.1 BAND SWITCH 2.2.2 TUNE 2.2.3 LOAD 2.2.4 POWER 2.2.5 OPR-STBY 2.2.6 QSK-PTT 2.2.7 MULTI-METER SWITCH 2.2.7.a Ep 2.2.7.b Is 2.2.7.c FWD 2.2.7.d REF 2.2.8 PLATE CURRENT METER 2.2.9 OVERDRIVE 2.2.10 WAIT 2.2.11 PEAK POWER BARGRAPH 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-1 2-2 2-2 2-2 2-2 2-2 2-2 2-2 2.3 2.4 2.5 REAR PANEL CONNECTIONS AND CONTROLS 2.3.1 TRANSCEIVER 2.3.2 ANTENNA 2.3.3 KEY IN 2.3.4 KEY OUT 2.3.5 PTT/VOX 2.3.6 ALC 2.3.7 ALC CONTROL 2.3.8 AC LINE 2.3.9 LINE FUSES INITIAL TURN-ON TUNE – UP PROCEDURE 2.5.1 CHECKS TO MAKE BEFORE TUNING UP 2.5.2 IMPORTANT POINTS TO REMEMBER 2.5.3 SUGGESTED TUNE – UP PROCEDURE 2-2 2-2 2-2 2-2 2-2 2-2 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-3 2-4 3 OPERATION AND SAF ETY 3.1 INTRODUCTION 3.1.1 TUBES 3.1.2 INTERLOCKS 3.1.3 FUSES 3-1 3-1 3-1 3-1 4 TROUBLESHOOTING 4.1 INTRODUCTION 4.2 MAINTENANCE 4-1 4-1 5 CIRCUIT DESCRIPTIO NS AND ILLUSTRATIONS 5.1 INTRODUCTION 5.2 INPUT MATCHING ASSEMBLY A6 (81946) AND 15M FILTER ASSEMBLY A7 (81953) 5.3 HIGH VOLTAGE RECTIFIER ASSEMBLY A2 (81944) 5.4 SCREEN SUPPLY AND GRID BIAS ASSEMBLY A10 (81950) 5.5 QSK ASSEMBLY A11 (81949) 5.6 SWR ASSEMBLY A4 / RELAY A14 (81951 / 81959) 5.7 PLATE CONNECTOR ASSEMBLY A3 (81948) 5.8 METER/SWITCH/DISPLAY ASSEMBLIES A12 and A13 (81947 and 81952) 5.9 HV-AC LINE INPUT ASSEMBLY A9 (81945) 5.10 LOAD SHUNT ASSEMBLY A5 (81943) 5.11 SCHEMATIC DIAGRAM, MODEL 417 AMPLIFIER 6 MASTER PARTS LIST ii 5-1 5-1 5-1 5-3 5-4 5-6 5-8 5-9 5-10 5-12 5-14 5-15 6-1 LIST OF ILLUSTRATIONS FIG 1-1 1-2 2-1 2-2 2-3 2-4 2-5 2-6 4-1 DESCRIPTION PAGE T/R CONNECTIONS FOR TEN-TEC TRANSCEIVERS WITH TX OUT AND TX EN T/R CONNECTIONS FOR OTHER TRANSCEIVERS MODEL 417 TUNING CHART MODEL 417 TUNING LOG MODEL 417 FRONT PANEL MODEL 417 REAR PANEL MODEL 417 TOP VIEW MODEL 417 BOTTTOM VIEW TROUBLESHOOTING HINTS 1-4 1-4 2-5 2-6 2-7 2-7 2-8 2-9 4-1 5-1 5-2 ASSEMBLY A6 (81946) INPUT MATCHING BOARD CIRCUIT TRACE COMPONENT LAYOUT 5-2 5-2 5-3 5-4 ASSEMBLY A2 (81950) H.V. POWER SUPPLY BOARD CIRCUIT TRACE COMPONENT LAYOUT 5-3 5-3 5-5 5-6 ASSEMBLY A10 (81950) SCREEN SPLY / GRID BIAS BOARD COMPONENT LAYOUT CIRCUIT TRACE 5-4 5-5 5-7 5-8 ASSEMBLY A11 (81949) QSK BOARD COMPONENT LAYOUT CIRCUIT TRACE 5-6 5-7 5-9 5-10 ASSEMBLY A4 (81951) SWR BOARD CIRCUIT TRACE COMPONENT LAYOUT 5-8 5-8 5-11 5-12 ASSEMBLY A3 (81948) PLATE CONNECTOR BOARD CIRCUIT TRACE COMPONENT LAYOUT 5-9 5-9 iii ASSEMBLY A12 (81947) METER/SWITCH BOARD 5-13 5-14 COMPONENT LAYOUT CIRCUIT TRACE 5-10 5-11 ASSEMBLY A13 (81952) DISPLAY BOARD 5-15 5-16 COMPONET LAYOUT & TOP CIRCUIT BOTTOM CIRCUIT TRACE 5-10 5-12 ASSEMBLY A9 (81945) AC LINE / DELAY BOARD 5-17 5-18 COMPONENT LAYOUT CIRCUIT TRACE 5-12 5-13 ASSEMBLY A5 (81943) LOAD SHUNT BOARD 5-19 5-20 CIRCUIT TRACE COMPONENT LAYOUT 5-14 5-14 5-21 SCHEMATIC DIAGRAM, MODEL 417 5-15 iv SPECIFICATIONS MODEL 417 BAND COVERAGE 160, 80, 40, 30, 20, 17, and 15 meters (12 and 10 meters for authorized users). POWER OUTPUT 1500 watts continuous in SSB, CW, AMTOR/PACTOR (50% duty cycle modes) on all bands. 1000 watts RTTY/SSTV (continuous duty cycle modes) for up to 10 minutes on 160, 80, 40, 20, 15, and 10 meter bands (750 watts on WARC bands 30, 17, and 12 meters). DRIVING POWER 60 watts typical for 1500 watts output. PLATE EFFICIENCY Up to 65% depending on band, frequency, line voltage and impedance load. INPUT AND OUTPUT IMPEDANCE 50 ohms unbalanced with VSWR <2:1 HARMONICS Meets or exceeds FCC requirements. CW BREAK-IN Built-in T/R switching in less than 7 ms. PROTECTIVE CIRCUITS A.) Screen grid voltage regulation, current limiting, over voltage protection and MOV arc over protection. LED over-current indication. B.) Control grid voltage regulation, current limiting and LED over-current indication. C.) Plate current over-current trip at 1.5 amps. Series resistor for arc absorption. PRIMARY POWER 240 VAC –10%/+5% @ 20 amps, 50/60 Hz LINE PROTECTION Primary line fuses, chassis interlock, and step-start inrush protection. TUBES Two Svetlana 4CX800A ceramic tetrodes in grid-driven configuration. COOLING Forced air, vertical exhaust, using centrifugal blower to produce .1” of water pressure drop at sea level, 25 degs. C air temperature. METERING Full time plate current meter. Second meter selectable for screen grid current, plate voltage, forward power, and reflected power (x10). Peak forward power indicated on full-time LED bargraph display. FRONT PANEL CONTROLS TUNE and LOAD control knobs with 6:1 reduction drive. Rotary band switch and meter switch for screen grid current, plate voltage, forward or reverse power. Standby / Operate , QSK / PTT-VOX and Power on/off rocker switches. STATUS INDICATORS Power on, wait, standby/operate, screen grid over-current, control grid over-current. PLATE VOLTAGE SUPPLY Step-start inrush protected. Approximately 3000 VDC @ no load, approximately 2700 VDC @ full load. 6 amp, 1000 PIV diodes in fullwave bridge circuit. 9 each 220 uF electrolytic filter capacitors. 10 ohm arc absorption resistor. SCREEN SUPPLY 360 VDC voltage regulated, current limited. CONSTRUCTION .125” aluminum plate transformer and RF tank chassis. .062” aluminum control / airbox chassis and covers. SIZE HWD = 8.5" x 19" x 20" (21.6 x 48.3 x 50.8 cm) WEIGHT 84 lbs. (38.18 kg) vi WARNING!!!!!!! This amplifier contains lethal voltages when operating. DO NOT operate this amplifier with the covers removed. The power supply circuits in this amplifier can produce up to 3000 volts and cause serious injury or death! CAUTION!!! Never attempt to operate the TITAN III without first connecting a suitable antenna or 50 ohm dummy load of sufficient power rating or SERIOUS DAMAGE MAY RESULT! 10 / 12 METER OPERATION OF THE TITAN III AMPLIFIER FCC rules permit licensed amateurs to modify their own amplifiers for operation in the 24.89 – 24.99 MHz and 28 - 29.7 MHz bands. If you enclose a copy of your valid amateur radio license with the warranty registration card for your new amplifier, an optional input matching circuit (assembly A8) and appropriate installation information will be sent to you without charge. vii INTRODUCTION The model 417 TITAN III is an advanced design linear amplifier using two 4CX800A high power tetrodes in a grid driven configuration. This amplifier uses a ducted forced air cooling system and operates easily at 1500 watts output with maximum efficiency of 65% . Two panel meters provide system monitoring. One meter is dedicated to full time plate current measurement. The other meter is switchable among plate voltage, screen grid current, forward power, or reflected power. Two front panel LEDs indicate overdrive conditions for the control grid and screen grid circuits. Plate current overdrive trip is provided at 1.5 amps. Band coverage includes 160, 80, 40, 30, 20, 17 and 15 meters as shipped from the factory. With proof of authorization, 12 and 10 meters may be enabled with an optional matching network from TEN-TEC. Primary power of 240 VAC is required. Remember, tune-up at 1500 watts output and 240 VAC line voltage can require up to 20 amps line current. The TITAN III primary AC lines are fused at 20 amps. ABC-20 fuses or equivalent must be used in replacement to protect the tubes. Interlocks on the high voltage power supply are provided to ensure operator safety. NEVER DEFEAT THESE SAFETY PRECAUTIONS !!!! viii UNPACKING Carefully remove the amplifier from the packing carton and inspect it for signs of damage. Carefully remove the high voltage power transformer from its’ packing carton and inspect it for signs of damage. If the amplifier or transformer has been damaged, notify the delivering carrier immediately, stating the full extent of the damage. Save all damaged cartons and packing material. Liability for any shipping damage rests with the shipping carrier. Complete the warranty registration form and mail to TEN-TEC immediately (include a copy of your amateur radio license if you are requesting the 10 meter option). Save the packing material for re-use in the event that moving, storage, or reshipment is necessary. Shipment of your TITAN III in other than factory packing material may result in damage. This is not covered under TEN-TEC warranty. The following hardware and accessories are packed with your TITAN III. Make sure you have not overlooked anything. 2 ea. 2 ea. 1 ea. 1 ea. 1 ea. 1 ea. 20 AMP ABC-20 fuses 11/2 AMP MDL-11/2 fuses key cable .056 allen wrench .062 allen wrench # 8 allen wrench 27038 27018 46160 38040 38088 38124 4 ea. #10 hex nuts (for plate transformer installation) 54005 2 ea. 4x40 long black flathead screw 24ea. 4x40 short black flathead screw (to finish installation of top cover) 60039 60080 1 ea. 1 ea. 2 ea 74020 74367 38265 warranty card operator’s manual spare 14” tube chimney clamp If any of the above are missing, contact the repair department at TEN-TEC for replacement. Repair dept. Switchboard FAX (865) 428-0364 (865) 453-7172 (865) 428-4483 Before powering up your TITAN III, visually inspect the unit for possible physical damage, such as dents or parts jarred loose during shipment. If you remove the top cover, remember that safety interlocks on both line and high voltage prevent power up. Do not connect this amplifier to AC power without the power transformer installed and the top cover securely held to the chassis with the provided cabinet screws. ix CHAPTER 1 INSTALLATION 1.1 INTRODUCTION: When setting up the station, provide adequate ventilation for the amplifier. Also, select a location that allows comfortable access to the front controls and adequate clearance for rear panel connections. 1.2 ELECTRICAL CONNECTIONS: The TITAN III amplifier draws up to 20 amps at 240 VAC. Care should be taken not to overload house wiring circuits usually fused or circuit breakered at 15 to 20 amps. A straight run circuit with # 10 / 2 wire with ground and breaker or fuses at 20 amps is strongly advised. Do not connect the TITAN III to AC voltage until installation of HV power transformer is completed. 1.3 HIGH VOLTAGE TRANSFORMER INSTALLATION: DO NOT CONNECT THE AC LINE CORD TO 240 VAC WALL OUTLET BEFORE INSTALLATION OF THE HV POWER TRANSFORMER. Check to make sure the amplifier is unplugged from the wall. Remove the top cover of the amplifier. Note only 8 screws were initially installed at the factory. This was done to simplify your task. Four of the screws are in the underside bottom edges (two long and two short). Temporarily remove the left side chassis rail (four short screws). There are four 10 x 32 nuts (TENTEC part #54005) in the packing kit. You must use these to mount the transformer and not the nuts in the transformer shipping carton. Identify the large open area in the chassis where the transformer mounts. Note the location of the four threaded studs in the chassis. Start two nuts only on the two studs closest to the center of the amplifier chassis. Just “start” the two nuts, engaging only a few threads. Orient the transformer with the two wire HV lead side of the transformer coil toward the center chassis shield. Being careful not to disturb the printed circuit board behind the meters, align the slots in the transformer bottom mounting bracket under the two nuts that you just installed. Slide the transformer toward the shield until the studs are seated in the transformer mounting slots about midway. Align the slots in the other bottom mounting bracket with the two remaining studs in the floor of the chassis near the outside of the amp. Install the two remaining nuts on the open studs. Using a long nut driver or socket, tighten all four nuts. Connect the two wire HV cable to the socket on the HV rectifier board A2 (81944) mounted on the center shield. Note the plug will seat properly in the socket in one direction only. Visually inspect the connection for proper seating. Connect the four wire primary cable to the four wire cable extending from the rear chassis area near the smaller low voltage transformer. Again this plug will only seat properly in one direction. Care should be taken when re-installing the side rail and top cover not to pinch this cable. Excess cable length may be looped and tucked between the side rail and fan housing scroll. Remember to install all 34 screws in the top cover when reassembling. The extras you need are in the packing kit. To access the five screws along each bottom edge, carefully tilt the amplifier on it’s side or slide it to the edge of the table and work from below. Note that the front two screws in each bottom edge are longer than the rest (4 long screws total). Never ship or transport the amplifier with the transformer installed !!! Serious damage to the chassis may result. 1-1 1.4 TRANSCEIVER INTERCONNECTIONS: When using the TITAN III with TEN-TEC transceivers with TX EN and TX OUT connectors, follow the diagram in Figure 1-1. The QSK-PTT/VOX switch on the TITAN III should be in the QSK position for all modes of operation. This hook-up arrangement will work with the OMNI series, PARAGON I and II, PEGASUS, JUPITER, and ORION. Some modern Yaesu transceivers are also equipped with a full break-in keying loop that can be utilized in a similar fashion. If you are unsure about connecting this equipment, please contact the TEN-TEC factory for instructions. When connecting the TITAN III with all other transceivers, use the diagram in Figure 1-2. Note that the key or keyer must be connected to the KEY IN jack on the TITAN III, a cable is run from KEY OUT to the key input jack on your transceiver, and the line from the external T/R N.O. relay contacts on the transceiver must be connected to the PTT/QSK jack on the TITAN III. When using this configuration, the QSK-PTT/VOX switch on the amplifier must be in the PTT/VOX position for SSB operation and in the QSK position for CW operation. 1.5 ANTENNA REQUIREMENTS: The TITAN III amplifier is designed for use with antennas resonant at the frequency of operation and having an impedance within the limit of 25 to 100 ohms, or an SWR of 2:1 or less (<10% reflected power). Note that any SWR other than 1:1 will result in TUNE and LOAD settings different from those in the manual reference chart (Figure 2-1). The nominal load impedance of the amplifier is 50 ohms. Antennas can exhibit an SWR of more than 2:1 in some part of the band. For operation under these conditions, we recommend using an antenna matching network that will enable the TITAN III to work into a 50 ohm load for maximum power transfer to the antenna. 1-2 CAUTION!!! Never attempt to operate the TITAN III without first connecting a suitable antenna or 50 ohm resistive load of sufficient power rating or SERIOUS DAMAGE MAY RESULT! 1.6 GROUND CONNECTION: In the interest of personal safety and to reduce the possibility of stray RF pickup on interconnecting cables, all station equipment should be well grounded to earth and to supply line ground bus. It is important to strap all equipment chassis together with short heavy leads. This ground bus may then be tied to an external earth grounding rod. 1.7 HIGH POWER OPERATION: The TITAN III amplifier operates comfortably at a maximum of 1500 watts output. New owners often find that other components in their station may not. Before operating at this power level, be certain to check the following items: 1. The coax from the TITAN III to the feed point of your antenna must be top quality RG-8 or better. We recommend silver plated connectors rather than chrome plated connectors. Make sure that all coax connectors are tight. 2. All coax switches or relays in the feed line must be rated at 1500 watts or higher. NEVER ACTIVATE INLINE SWITCHES WHILE TRANSMITTING. 3. Verify that the components in your antennas are rated for the TITAN III maximum power levels (dipole center insulator, end insulators, baluns, traps, etc.) Make sure that all radiating sections are well clear of metallic objects such as rain gutters and antenna supporting structures. For the first few hours of operation, check the SWR frequently. Any increase in reflected power is an indication that something between the amplifier and the antenna elements, including the end insulators, is heating and must be corrected. 4. A solid earth ground is often essential. Every station will have a unique electrical ground due to location of equipment, distance between units, distance from house wiring ground rod, distance from RF ground rod, etc. Keep equipment ground straps as short and thick as possible and RF ground rod as close to the station as possible. 5. If you use an antenna tuner, make all SWR/matching adjustments with the TITAN III in the STANDBY mode using transceiver low power only. 6. If any of your home entertainment electronic devices have RF leaks, the TITAN III may find them. If you are not familiar with standard procedure for controlling this type of interference, consult the ARRL Radio Frequency Interference Manual. depending on input RF drive level. A negative output voltage will be present at the ALC jack only when the TITAN III is in the OPERATE mode and the input RF drive is above the threshold setting. Leave this control fully clockwise if you have no requirement for external ALC. 1.9 COOLING SYSTEM: The TITAN III uses a pressurized cabinet with the main air intake through the right front side of the chassis and exhaust through the tube chimneys on the right rear top of the amplifier. It is safe to operate the amplifier as long as there are no impediments to the flow of air near the air intakes and/or the exhaust. 1.8 ALC: Most solid state transceivers do not provide connection for ALC input and it is unnecessary to make any external ALC connection to these rigs. The ALC output jack is used primarily with tube-type transmitters or transceivers with a negative going ALC system. The ALC ADJUST control is used to set the threshold for proper ALC action. This is -1 to -15 VDC 1-3 TITAN III TITAN III FIGURE 1-1 T/R CONNECTIONS FOR TEN-TEC TRANCEIVERS WITH TX OUT & TX EN TITAN III TRANSCEIVER TITAN III FIGURE 1-2 T/R CONNECTIONS FOR OTHER TRANCEIVERS WITHOUT TX OUT & TX EN 1-4 CHAPTER 2 OPERATING INSTRUCTIONS 2.1 INTRODUCTION: The following instructions will enable the operator to quickly place the TITAN III in operation. Included are descriptions of the front panel controls and rear panel connections, followed by a detailed tuneup procedure. Refer to Chapter 3 operation and safety tips. 2.2 FRONT PANEL CONTROLS: The front panel controls and their functions are described below. 2.2.1 BAND SWITCH: This switch selects the desired frequency of operation. This is an eight position switch that covers the 160 meter to 10 meter bands. NOTE: A built-in switch stop prevents operation in the 10 and 12 meter bands. For 10 and 12 meter operation you must contact the factory for an authorized modification kit. 30 meter operation is done in the 40B position, 17 meter operation in the 15 meter position, 12 meter operation in the 10 meter position. 2.2.2 TUNE: This control adjusts variable capacitor C1 to provide resonance at the operating frequency. Figure 2-1 shows the approximate settings for both the TUNE and LOAD controls on each band. Keep in mind that the settings in this chart are for operation into an ideal 50 ohm resistive load. There is also a blank log chart that you may use to record the actual control settings for your antennas. 2.2.3 LOAD: This control adjusts variable capacitor C2 for the proper amplifier output loading. See Figure 2-1. 2.2.4 POWER: This switch routes the AC line to the primary of the low voltage supply. When on, the TITAN III will power up and the indicator light in the POWER switch will light. 2.2.5 OPERATE/STANDBY: This switch, when in the OPERATE position, places the amplifier online. When in the STANDBY position, the amplifier is bypassed and only the transceiver power is routed to the antenna. When in the OPERATE position, the indicator light in the switch will light. NOTE: No high voltage will be read on the metering when this switch is in STANDBY. The OPERATE/STANDBY switch also serves as the plate current trip-off circuit reset switch. At 1.5 amps plate current, the plate current trip-off circuitry will activate. The lighted segment of the OPERATE/STANDBY switch will go out when plate current trip-off has occurred. To reset, switch back to STANDBY and immediately back to OPERATE. The lighted segment of the switch should now be lit again and the amplifier is ready to use. 2.2.6 QSK/PTT: This switch, when in the QSK position, configures the key circuits for CW/QSK operation. For late model TENTEC transceivers with TX EN and TX OUT connectors, or late model Yaesu transceivers connected using a full break-in keying loop, this position is used for all modes of operation. Placing the switch in the PTT position allows the TITAN III to be controlled by the PTT/VOX input jack rather than the KEY IN/KEY OUT loop. 2.2.7 MULTIMETER SWITCH: This switch connects the right hand meter to monitor various amplifier parameters. A. Plate voltage (Ep) - When in this position, the meter reads plate voltage. This voltage is line voltage dependent at a ratio of 12.5 V plate per 1 V line. Plate voltage is approximately 3000 VDC at a line voltage of 240 VAC. Therefore, at a line voltage of 250 2-1 VAC the meter will read a little higher (3125 VDC). B. Screen current (Is) - When in this position, the meter is paralleled with a resistor in series with the screen supply. This monitors screen grid current. The upper limit for screen current is 75 mA. NEVER OPERATE THE TITAN III IN EXCESS OF 75 mA SCREEN GRID CURRENT. A warning zone indicator is used on the face of the meter to alert the operator. In addition to the analog meter, the screen overdrive LED indicates excessive screen current. C. Forward power (FWD) - When in this position, the meter is connected to the forward port of a bridge circuit at the antenna output. This measures forward RF output power. It is, however, more load dependent than an external wattmeter. If your antenna is far from resonance, the accuracy is not as good and power measurements should be made externally. D. Reflected power (REF) - When in this position, the meter is connected to the reverse port of the bridge at the antenna output. Reflected power is read at 1/10 indication scale of forward power (200 watts full scale). 2.2.8 PLATE CURRENT METER: Full time plate current metering is provided by the left analog meter. 2.2.9 OVERDRIVE: These two LEDs indicate grid overdrive conditions. A. When the screen overdrive LED is lit, the screen current is approaching or has passed its limit. Reduce drive from the transceiver immediately and retune. B. When the control grid overdrive LED is lit, the control grid current is approaching or has passed its limit. Reduce drive from the transceiver immediately and retune. 2.2.10 WAIT: This LED indicates a 3 minute warm-up period for the tube at initial power up. After being turned on for 3 minutes, the wait 2-2 LED goes out and the TITAN III can be placed in the operate mode. 2.2.11 PEAK POWER BARGRAPH: This meter is connected to the bridge at the antenna output through an emitter follower to monitor peak RF output power. When the red LED is lit, 1500 watts output has been reached. 2.3 REAR PANEL CONNECTIONS AND CONTROLS: The rear panel connections and their functions are described below. 2.3.1 TRANSCEIVER: This is a standard SO-239 receptacle designed for a mating PL-259 plug. RG-58U or similar 50 ohm coax is required to connect the TITAN III to the transceiver. 2.3.2 ANTENNA: This is a standard SO239 receptacle designed for a mating PL-259 plug. RG-8 or similar 50 ohm coax rated for 1500 watts is required for connection to the antenna. 2.3.3 KEY IN: This jack is the input for the TITAN III transmit/receive relay system. When used with late model TENTEC transceivers, this jack is connected to the TX OUT connector on the transceiver. When used with other transceivers, a key or keyer is connected to this jack for CW operation. 2.3.4 KEY OUT: This jack is a protected output from the TITAN III which passes the KEY IN to the transceiver after all relays in the TITAN III have closed and it is ready to transmit. When used with late model TENTEC transceivers, this jack is connected to the TX EN connector on the transceiver. When used with other transceivers, this jack is connected to the transceiver key input jack. 2.3.5 PTT/VOX: This jack is an input to the TITAN III transmit/receive relay circuits. When used with late model TEN-TEC transceivers, this jack is not used. When used with other transceivers, this jack is connected to the normally open (grounding) contacts of the relay key out jack of the transceiver. 2.5 TUNE UP PROCEDURE: The following section describes important points to observe during tune up. A suggested procedure for safely tuning up the TITAN III is included. 2.3.6 ALC: This jack provides a negative going ALC voltage, used primarily with tube type transmitters/transceivers. See section 1.8 for detailed information. 2.5.1 CHECKS TO MAKE BEFORE TUNING UP: Check the load connected to the amplifier. This can best be done by leaving the TITAN III in the BYPASS mode and using only the transceiver output power. Use a reliable SWR bridge or wattmeter to determine the SWR of the load (antenna) connected to the amplifier. If the reflected power is less than 10% of the forward power, the VSWR is less than 2:1. If the reflected power is 4% or less, the VSWR is 1.5:1 or lower. A VSWR of 2:1 or less is essential. 2.3.7 ALC CONTROL: This control adjusts the ALC threshold voltage from approximately 1 to -15 VDC depending on RF input from the transceiver. 2.3.8 AC LINE: This cable is connected to standard 240 VAC. Be sure the line used to power the TITAN III is capable of supplying 20 amps of current at 240 VAC, and that it is protected by either fuses or circuit breakers of 20 amps. Wire size of the AC feed line should be at least 10/2 with ground or larger. 2.3.9 LINE FUSES: Primary line fuses (ABC20) are accessible through these panel fuse holders. Replace with ABC-20 or comparable fuses only. 2.4 INITIAL TURN-ON: The following steps should be followed when turning on your TITAN III. A. Set multimeter switch to the plate voltage (Ep) position. B. Place the power switch to ON. If any of the following do not occur, press OFF at once and investigate before proceeding. 1. The power switch light should light. 2. The meter lights should light. 3. The fan motor should start and air flow should be felt at the exhaust port on top of the amplifier. 4. The wait LED should light. 5. All meter indications are zero. 6. All other LEDs are not lit. NOTE: HIGH VOLTAGE IS PRESENT ONLY IN THE OPERATE MODE. THE OPERATE MODE IS DISABLED FOR 3 MINUTES WHILE THE WAIT LED IS LIT. 2.5.2 IMPORTANT POINTS TO REMEMBER: The most important parameters to observe during tune up are the control grid current and screen grid current. Excessive grid current even for a relatively short period of time can and will damage the tube. If grid currents are not exceeded, the 4CX800A tubes will deliver many years of trouble free service. In the TITAN III the control grid is monitored by front panel LED indicator. When control grid current is exceeded, the GRID overdrive LED will light. Reduce the drive immediately and retune the TITAN III. Screen grid current is monitored by the multimeter, (when in the Is position) and by an LED overdrive indicator continuously. Screen grid current should be kept to a minimum during tune up and always in a positive direction. When screen current is exceeded the SCREEN overdrive LED will light. Reduce drive immediately and retune. After tune up, erratic lighting of either overdrive indicator could indicate breakdown in the load (antenna components). Reduce drive and check for arcing or heating of baluns, coax or other elements. Brief blinks of the LEDs at initial power-on or key-down are OK. 2-3 2.5.3 SUGGESTED TUNE UP PROCEDURE: Following is the recommended procedure for safe and proper tune up of the TITAN III. A. Set the band switch to the desired band. For 30 meter operation, use position 40B. For 17 meters, position 15. For 12 meters, position 10. B. Set the multimeter switch to the Ep position. C. After the wait LED goes out, place the STANDBY/OPERATE switch to OPERATE. The STANDBY/ OPERATE switch will light and high voltage is indicated on the multimeter (nominal 3000 VDC). D. Set the meter switch to the Is position. Always monitor Is (screen grid current) with the multimeter during tune up. Use FWD and REF positions momentarily for checking output power. Output power can also be monitored on the LED bargraph power meter. Always monitor the overdrive LEDs. Reduce drive and retune the amplifer if either is lit. E. For initial tune up you may set the TUNE and LOAD controls to their center positions. Alternatively you may refer to the suggested settings in the chart in Figure 2-1. Keep in mind that these settings are for operation into an ideal 50 ohm load and will vary with your installation. F. Turn the transceiver RF output control to between 10 and 20 watts. Note: at very low transceiver power outputs (<10 watts) the amplifier may not respond when attempting to tune up. This is normal. Increase drive power slightly and continue tune up. IF AT ANY TIME THE TITAN III DOES NOT RESPOND AS EXPECTED, REMOVE DRIVE POWER IMMEDIATELY AND CORRECT THE PROBLEM BEFORE CONTINUING. G. Key the transceiver and slowly increase the drive power until you see the plate current increase. H. Adjust the TUNE control for a peak in screen grid current and a peak in RF 2-4 power output. Adjust the LOAD control for minimum screen grid current consistant with desired power output. You will find that these values are not always synchronized. Choose the lower grid current adjustment even if the power output is slightly less. Readjust the TUNE control for a screen grid current and power output peak each time you adjust the LOAD control. There will be some interaction between these controls. I. Gradually increase the drive level from the transceiver until you reach the desired output power level while carefully touching up the LOAD and TUNE controls for minimum screen grid current and maximum output power, respectively. NEVER EXCEED 75 MILLIAMPS SCREEN GRID CURRENT. J. Once you have the amplifier tuned up and operating on the desired frequency, you can log the LOAD and TUNE settings in the chart provided (Figure 2-2). These settings should be repeatable for the same frequency, antenna, and SWR when used in the future. BAND FREQUENCY MHz LOAD TUNE 160A 1.820 6.1 4.1 160B 1.980 5.5 3.500 8.7 7.5 3.980 5.5 4.7 40A 7.040 3.6 1.6 40B 10.120 14.050 1.5 1.5 14.250 1.4 1.1 18.110 2.1 5.2 21.050 1.4 1.5 12 24.900 2.5 4.2 10 28.100 1.6 .5 80 / 75 20 15 FIGURE 2-1 MODEL 417 TUNING CHART FOR AN IDEAL 50 OHM LOAD 2-5 BAND FREQUENCY LOAD TUNE ANTENNA FIGURE 2-2 MODEL 417 TUNING LOG 2-6 NOTES FIGURE 2-3 TITAN III FRONT VIEW FIGURE 2-4 TITAN III REAR VIEW 2-7 FIGURE 2-5 TITAN III TOP VIEW 2-8 FIGURE 2-6 TITAN III BOTTOM VIEW 2-9 CHAPTER 3 OPERATION AND SAFETY 3.1 INTRODUCTION: The following paragraphs provide additional information for operation of and safety from your TITAN III amplifier. 3.1.1 HIGH POWER TETRODES: The 4CX800As are very rugged and normally operate with a large margin of safety in the TITAN III. They will deliver outstanding service for many years if not damaged by abuse...especially excessive grid current or blockage of cooling air flow. KEEP THE AIR INTAKE AND EXHAUST VENT AREAS COMPLETELY CLEAR !!! WARNING !!! DO NOT ALLOW THE SCREEN GRID CURRENT TO EXCEED 75 mA! 3.1.2 INTERLOCKS: The TITAN III is equipped with interlock switches intended to shut off the power and short out the high voltage power supply when the cover is not securely fastened in place. These protective interlocks are provided to protect you from POTENTIALLY FATAL ELECTRIC SHOCK resulting from accidental contact with lethal voltages inside the amplifier. However, you should never depend on interlocks alone to protect you by removing dangerous voltages. ALWAYS DISCONNECT THE AC LINE CABLE TO THE TITAN III BEFORE REMOVING THE TOP COVER. WARNING !! THE AMPLIFIER SHOULD NEVER BE ENERGIZED WITH THE COVERS REMOVED!! DO NOT DEFEAT THE INTERLOCK SAFETY SWITCHES!! 3.1.3 FUSES: Except in rare instances of component failure, blowing one or both primary fuses indicates that maximum safe average power capabilities of the amplifier have been exceeded. 3-1 CHAPTER 4 MAINTENANCE AND TROUBLESHOOTING 4.1 INTRODUCTION: If you encounter a problem, the troubleshooting hints listed in TABLE 4-1 below will help isolate the nature of the problem. 4.2 MAINTENANCE: The amplifier compartment, particularly areas around high voltage components should be cleaned often (using a soft bristled brush and vacuum cleaner) to prevent visible accumulation of dust. DO NOT blow air directly into the fan input: this can over rev the motor and damage the bearings. TABLE 4-1 TROUBLESHOOTING HINTS SYMPTOM POSSIBLE CAUSE/CURE 1. Will not turn on: nothing happens when the ON switch is activated. A] Fuse missing or open. B] House wiring incorrect or breaker open. C] Power cable to amplifier disconnected. D] Fuse on HV-AC board A9 (81945) open. E] Problem with low voltage power supply on QSK board A11 (81949) 2. Lights turn on but no high voltage. A] No HV will be present until amp is switched to OPERATE mode (and timed out). 3. Relays A9K2 and A9K3 on 81945 HVAC board close but relay K1 does not. Plate Voltage drops when RF is applied. A] A9Q1 on 81945 HV-AC board is defective. B] A9K1 on 81945 is defective. 4. Relays A9K1, A9K2, A9K3 on 81945 HV-AC board close but no high voltage when switched to OPERATE mode. A] Interlock open, cover not tight B] A9K2, A9K3 defective. C] HV short to ground. D] High voltage transformer disconnected. E] High voltage bridge open. 4-1 TABLE 4-1 TROUBLESHOOTING HINTS (Continued) 5. Relays A9K1, A9K2, and A9K3 close at turn on, but line fuses blow. 6. Amplifier won’t drive, zero grid and plate current, high input SWR . 7. Grid overdrive LED lights with no drive. 8. Screen overdrive LED lights with no drive. 9. Amplifier difficult to drive, little or no output, high plate current (may be accompanied by a “frying sound”). 10. Excessive plate current in receive mode. A] High voltage shorted at crowbar or elsewhere. B] Shorted tube. C] Leaky electrolytics in high voltage supply. A] Defective cable from transceiver to amplifier. B] Input relay A4K2 on 81951 SWR board defective. C] Input filter A7 or A8 on 81946 Input Matching board (A6) loose or damaged. A] A10Q7 on 81950 Screen Supply shorted or leaky. B] Shorted or leaky tube. A] A10R23 on 81950 Screen Supply open or increased in value. B] Low or no high voltage. TURN OFF THE AMPLIFIER IMMEDIATELY. A] Band switch in wrong position. B] Excessively high load SWR. C] Defective output relay A4K1 on 81951 SWR board. D] Arcing in tank circuit or antenna feed line. A] Defective bias circuit, 81950 board (A10). B] Shorted grid /cathode in tube. 11. Transceiver does not key using key-in/keyout loop. A] Key-in and key-out lines reversed at amplifier or at transceiver. B] Defective key line cables. C] Defective relay control circuit on 81949 QSK board (A11). 12. Transceiver stays keyed in receive mode. May be accompanied by loss of receive signal. A] Relay A4K1 on 81951 SWR board stuck. B] Shorted key-in or key-out cable. C] Defective relay control circuit on 81949 QSK board (A11). 4-2 CHAPTER 5 CIRCUIT DESCRIPTIONS AND ILLUSTRATIONS 5.1 INTRODUCTION The following sections contain detailed circuit board subassemblies used in the model 417. Also included are circuit trace drawings and detailed component layout diagrams. These drawings are followed by a schematic diagram for the complete amplifier. 5.2 INPUT MATCHING BOARD A6 (81946) This board contains the input filter, impedance matching networks, and ALC circuits. The 15M INPUT FILTER BOARD A7 (81953) is the standard input filter shipped with the TITAN III. This is a five pole elliptic filter consisting of L1, L2, L3, C1, C2, and C3. This filter provides increased roll-off of frequencies above the 15 meter band. An optional 15/10M INPUT FILTER BOARD A8 (81954) is available from TEN-TEC to qualified amateur radio operators, upon receipt of a copy of their amateur radio license. Note: Operation on the 10 meter band will also require additional modifications to the bandswitch assembly. Please contact the factory for instructions or further information. The impedance matching network of R4–R12 and L3 on assembly A6 matches the input impedance of the 4CX800As to the input filter board. The ALC circuit on A6 samples the input RF power to the amplifier. A6D1 rectifies this sample and produces a negative voltage proportional to input power for control of some exciters. The ALC threshold is set by potentiometer A11R52, located on the rear panel. Turn this control fully clockwise if ALC is not used. 5-1 FIGURE 5-1 INPUT MATCHING BOARD (ASSEMBLY A6) CIRCUIT TRACE AS VIEWED THROUGH BOARD FIGURE 5-2 INPUT MATCHING BOARD (ASSEMBLY A6) COMPONENT LAYOUT TOP VIEW 5-2 H.V. POWER SUPPLY BOARD A2 (81944) This board contains the high voltage rectifier bridge (D1 – D20), H.V. filters (C1 – C8 and C14), and H.V. meter circuits. FIGURE 5-3 HIGH VOLTAGE RECTIFIER BOARD (ASSEMBLY A2) CIRCUIT TRACE AS VIEWED THROUGH BOARD FIGURE 5-4 HIGH VOLTAGE RECTIFIER BOARD (ASSEMBLY A2) COMPONENT LAYOUT TOP VIEW 5-3 5.4 SCREEN SUPPLY AND GRID BIAS BOARD A10 (81950) This board contains the screen supply, grid bias supply, and protective circuits for the 4CX800As. The screen voltage is rectified by diodes D4 – D7 and filtered by C1 – C3 and C15. This DC voltage is then regulated by pass element Q8. Load resistors R25 – R27 provide a current drain to insure screen current remains in the positive direction. MOV Z1 protects the power supply in the event of tube arc and insures the screen voltage can’t surge above 450 VDC. R23 provides a voltage drop proportional to the screen current to drive the front panel screen current meter. Grid bias voltage is rectified by D13, then filtered by C10. Q1 senses the key condition and via Q2 and Q4 switches zener diodes D2, D8 and D16 in during key down and out during key up. This zeners the bias voltage to approximately –55 VDC during TX and –100 VDC in RX. Due to differences in tubes, J21 allows adjustment of grid bias in 4 settings: -47V -55V -60V -68V Pins 1 and 3 shorted Pins 2 and 3 shorted Pins 1 and 2 shorted no pins shorted This adjustment is factory set to match the tubes shipped with the amp. If the tubes are ever replaced, the jumper setting should be selected to produce approximately 200 – 400 mA of plate current when keyed with no drive. The circuitry of Q7 senses grid current and begins to fold back grid bias toward cutoff as grid power approaches 2 watts. Zener diode D1 provides regulation for the negative 16 VDC power supply to run the meter circuits on the meter switch board and the relay hot-shot circuit on the SWR board. FIGURE 5-5 SCREEN SUPPLY BOARD (ASSEMBLY A10) COMPONENT LAYOUT TOP VIEW 5-4 TOP SIDE COPPER BOTTOM SIDE COPPER FIGURE 5-6 SCREEN SUPPLY (ASSEMBLY A10) CIRCUIT LAYOUT VIEWED THROUGH BOARD FROM TOP 5-5 5.5 QSK BOARD A11 (81949) This board contains the low voltage supply, turn-on relay sequencing circuits, and T/R relay control. The low voltage is rectified by D1 – D4 and filtered by C6. U1 and Q2 provide regulation for all low voltage circuits except the negative 16 VDC supply. After a 3 minute warm-up period determined by RC time constant of R4 and C5,Q19 and Q11 will conduct, turning on the pass element Q7. This initiates amplifier power up. When the STANDBY/ OPERATE switch is put in the OPERATE position, this voltage is applied to relay sequencing circuits Q3, Q6, Q4 and Q10. These circuits insure plate and screen voltages arrive at and leave the tube in the proper order. Q20 senses plate current and disables the amplifier when plate current parameters are exceeded (such as excessive plate current during a tube arc). Both plate voltage and screen voltage are removed when plate current of 1.5A is reached. The QSK CONTROL CIRCUIT consists of Q12-Q18 and Q21-Q23. This circuit samples input key requests, standby/operate modes, power on/off state, state of output relay, and RF presence at the antenna connection and input of the amp. Hot switch protection is provided regardless of mode. In the QSK mode, using the key in / key out loop, the key in request from the transceiver is tailored by the QSK CONTROL circuit to insure smooth QSK action of the input and output relays. K2 senses power OFF or STANDBY and places the key circuit in bypass for operation in barefoot mode. K3 senses OPERATE mode and routes the key request to the amplifier control circuits. K4 passes the “key in” to the KEY OUT jack when all relays are closed and ready for RF. FIGURE 5-7 QSK BOARD (ASSEMBLY A11) COMPONENT LAYOUT TOP VIEW 5-6 FIGURE 5-8 QSK BOARD (ASSEMBLY A11) TOP AND BOTTOM CIRCUIT TRACES VIEWED THROUGH BOARD FROM TOP 5-7 5.6 SWR BOARD A4 (81951) This board contains the input relay K1, output relay A14, hotshot speed-up circuit Q3-C19, and the SWR bridge T1 for output power sampling. FIGURE 5-9 SWR BOARD (ASSEMBLY A4) CIRCUIT TRACE VIEWED THROUGH BOARD FROM TOP TOP COPPER BOTTOM COPPER FIGURE 5-10 SWR BOARD (ASSEMBLY A4) COMPONENT LAYOUT TOP VIEW 5-8 5.7 PLATE BOARD A3 (81948) This board contains the parasitic suppressors and coupling capacitors to connect the 4CX800A plates to the amplifier tank circuit. FIGURE 5-11 PLATE CONNECTOR BOARD (ASSEMBLY A3) CIRCUIT TRACE VIEWED THROUGH BOARD FIGURE 5-12 PLATE CONNECTOR BOARD (ASSEMBLY A3) COMPONENT LAYOUT TOP VIEW C1 C2 R7 C3 R1 R6 R2 R4 C4 R10 R3 R5 R9 R8 5-9 5.8 METER/SWITCH BOARD A12 (81947) and DISPLAY BOARD A13 (81952) This board contains the metering circuits for the front panel meters. A12S1 selects the parameter to be monitored. This selection is then sent to multimeter M1. The multimeter has three calibrated scales for measuring plate voltage, screen current and forward or reflected RF power. The KW scale should be divided by ten when measuring reflected power. A12U1 samples screen and control grid current and drives the appropriate LED to indicate excessive current of either screen or control grid. Q1 samples forward RF power voltage from the SWR board. This voltage is peak-held by C8 and sent to U2 to drive the peak reading display LEDs on DISPLAY BOARD A13. FIGURE 5-13 METER/SWITCH BOARD (ASSEMBLY A12) COMPONENT LAYOUT VIEWED FROM FRONT PANEL SIDE U1 GRN U2 GRN U3 GRN U4 GRN U5 GRN U6 GRN U7 RED FIGURE 5-15 DISPLAY BOARD (ASSEMBLY A13) COMPONENT LAYOUT AND TOP CIRCUIT VIEWED FROM TOP 5-10 COMPONENT SIDE COPPER SOLDER SIDE COPPER FIGURE 5-14 METER/SWITCH BOARD (ASSEMBLY A12) CIRCUIT VIEWED THROUGH BOARD FROM FRONT PANEL 5-11 FIGURE 5-16 DISPLAY BOARD (ASSEMBLY A13) BOTTOM CIRCUIT VIEWED THROUGH BOARD FROM TOP U1 GRN 5.9 U2 GRN U3 GRN U4 GRN U5 GRN U6 GRN U7 RED AC LINE DELAY BOARD A9 (81945) This board contains the step start relays and associated circuitry to control inrush current while the H.V. filter capacitors charge. FIGURE 5-17 AC LINE DELAY BOARD (ASSEMBLY A9) COMPONENT LAYOUT TOP SIDE VIEW 5-12 TOP COPPER BOTTOM COPPER FIGURE 5-18 AC LINE DELAY BOARD (ASSEMBLY A9) CIRCUIT TRACE TOP VIEW THROUGH BOARD 5-13 5.10 LOAD SHUNT BOARD A5 (81943) This board contains some of the extra load capacitance needed for the tank circuit on the 160M band. Capacitance is paralleled across the variable load capacitor on bandswitch positions 160A, and 160B, and 80. FIGURE 5-19 LOAD SHUNT CAP BOARD (ASSEMBLY A5) CIRCUIT VIEWED THROUGH BOARD FROM TOP BOTTOM COPPER TOP COPPER C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 81943 Assembled 78254 Rev A FIGURE 5-20 LOAD SHUNT CAP BOARD (ASSEMBLY A5) COMPONENT LAYOUT TOP VIEW 5-14 FIGURE 5-21 SCHEMATIC DIAGRAM MODEL 417 5-15 CHAPTER 6 MASTER PARTS LIST MODEL 417 CHASSIS MOUNTED PARTS A1 ITEM DESCRIPTION TEN-TEC PART # T1 T2 BLOWER S1 S2 S3 S4 S5 S6 L1 L2 L3 L4 L5 L6 C1A C1B C2 C4 C5 C6 C8 C10 P3 V1 V2 V1/V2-S F1-F2 HV TRANSFORMER LV TRANSFORMER CENT. BLOWER SHORTING BAR INTERLOCK SW ON-OFF SW STBY-OPR SW QSK –PTT SW BAND SW P/O TANK COIL-1 P/O TANK COIL-1 TANK COIL-2 10M PI COIL 15/10M PLATE MATCH PLATE CHOKE TUNE CAPACITOR LOAD CAPACITOR 150pF 5KV N750 150pF 5KV N750 .01uF 1KV .01uF 1KV 400pF 7.5KV N3300 AC PLUG 4CX800A TETRODE TUBE SOCKETS W/BYP 20 ABS FUSE FUSE HOLDER 6:1 VERNIER TUBE RETAINER BAR KNOB LOAD-TUNE KNOB DIAL SKIRT METER SW KNOB BAIL RT BAIL FOOT LF BAIL FOOT REAR FEET HOLE PLG - MTR ADJ 81859 FROM 21199 21198 38305 93690 32063 32128 32129 32130 98545 FROM 32144 85427-2 85427-2 85427-3 85427-6 85427-4 85427-1 23520 23526 23297 23297 23013 23013 23300 35153 25513 27084 27038 27009 38146 38265 34058 81601 91209-1CU 80529 91178 90926 90925 42020 42044 6-1 AC LINE BOARD A9 81945 ITEM DESCRIPTION TEN-TEC PART # C1 C2 C3 C4 K1 K2 K3 .01uF 1KV .01uF 1KV 1uF 50V .01uF 1KV RELAY SPST RELAY SPST RELAY SPST COVER, RELAY MPSA14 33K 100K 22K 10 25W 1.5 AMP MDL 23013 23013 23264 23013 32067 32067 32067 32072 25253 30155 30161 30154 30310 27018 Q1 R1 R2 R3 R4 F1 F2 INPUT MATCHING BOARD A6 81946 C1 C2 C3 C4 D1 FL1/A7 L1 L2 L3 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 6-2 15pF 1KV .01uF 100pF .01uF 1KV 1N4148 15M INPUT FILTER 1MH COIL-TOROID, .7uH 100K 10K 150K 2W 470 7W 470 7W 470 7W 47 OHM 2W 47 OHM 2W 47 OHM 2W 47 OHM 2W 47 OHM 2W 50 OHM 90WATT 23372 23260 23013 23385 28001 81953 21135 85427-7 30161 30150 30311 30721 30721 30721 30408 30408 30408 30408 30408 30223 METER-SWITCH BOARD A12 81947 ITEM DESCRIPTION TEN-TEC PART # C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 C22 C23 C24 C25 D1 D2 D3 D4 M1 M2 Q1 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 .01uF .01uF .01uF .01uF .01uF .1uF .01uF 1uF 50V .01uF .01uF .1uF .1uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .1uF .01uF .01uF LED LED LED 1N4148 MULTIMETER 1mA PLATE METER 1mA 2N4124 10K TRIMPOT 10K TRIMPOT 10K TRIMPOT 1M 1K 10K 10K 47K 1K 1M 10K TRIMPOT 23260 23260 23260 23260 23260 23261 23260 23264 23260 23260 23261 23261 23260 23260 23260 23260 23260 23260 23260 23260 23260 23260 23261 23260 23260 28024 28024 28024 28001 98540 98544 25258 30038 30038 30038 30173 30138 30038 30038 30157 30138 30173 30038 6-3 ITEM DESCRIPTION TEN-TEC PART # R12 R13 R14 R15 R16 R17 R18 R19 R20 R21 R22 R23 SW1 U1A U1B U2 4.7K 2.2K 330 1.5K 100K 100K 100K 10K TRIMPOT 100K PC ADJ 100K PC ADJ 10K TRIMPOT 100K TRIMPOT METER SW P/O LM393 P/O LM393 LM3914 30146 30142 30132 30140 30161 30161 30161 30038 30620 30620 30038 30198 98449 FROM 32050 25260 25260 25101 PLATE BOARD A3 81948 C1 C2 C3 C4 L1 L2 R1-R5 R6-R10 .001uF 6KV .001uF 6KV .001uF 6KV .001uF 6KV PARASITIC SUP 150 2W 150 2W 23295 23295 23295 23295 85427-5 30407 30407 QSK BOARD A11 81949 C1 C2 C3 C4 C5 C6 C7 C8 C9 6-4 4.7uF 35V .1uF 1uF 50V 33uF 16V 33uF 16 4700uF 35V 1uF 50V .1uF 10uF 23310 23261 23264 23308 23308 23191 23263 23261 23266 ITEM DESCRIPTION TEN-TEC PART # C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C21 C22 C23 C24 C25 C26 C27 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 K1 K2 K3 K4 L1 Q1 Q2 Q3 Q4 Q5 Q6 Q7 Q8 Q9 Q10 Q11 10uF 10uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .01uF .56uF 1uF 50V .01uF .01uF .1uF 1N5401 1N5401 1N5401 1N5401 1N4148 1N4148 1N4148 1N4148 1N750 4.7V ZENER 1N4148 1N4148 1N4148 1N4148 1N4148 SCRN RELAY KEY/OFF RELAY OP/STBY RELAY KEY_OUT RELAY 100UH MPSW01 MJE371 MJE371 MJE371 MJE371 2N4124 2N4124 2N4124 2N4124 MPSW01 2N5060 SCR 23266 23266 23260 23260 23260 23260 23260 23260 23260 23260 23260 23260 23331 23263 23260 23260 23261 28047 28047 28047 28047 28001 28001 28001 28001 28058 28001 28001 28001 28001 28001 32103 32120 32120 32081 21060 25023 25105 25105 25105 25105 25258 25258 25258 25258 25053 25039 6-5 ITEM DESCRIPTION TEN-TEC PART # Q12 Q13 Q14 Q15 Q17 Q18 Q19 Q20 Q21 Q22 Q23 R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 R15 R16 R17 R19 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29 R30 R31 R32 R34 R35 R37 MPSW01 2N4124 2N4124 2N4124 2N4124 2N4124 2N6027 UJT 2N5087 2N4124 2N5087 2N4124 1K 1K 10K 3.9M 1K 1K 1.5K 1K 1K 1K 1K 10K 10K 10K 22K 22K 22K 47 10K 1K 1.5K 10K 10K 2.2K 10K 100 1K 8.2K 2.2K 10K 10K 10K 270 10K 25053 25258 25258 25258 25258 25258 25185 25001 25258 25001 25258 30138 30138 30150 30180 30138 30138 30140 30138 30138 30138 30138 30150 30150 30150 30154 30154 30154 30122 30150 30138 30140 30150 30150 30142 30150 30126 30138 30149 30142 30150 30150 30150 30131 30150 6-6 ITEM DESCRIPTION TEN-TEC PART # R38 R39 R40 R41 R42 R43 R45 R46 R47 R48 R49 R50 R51 R52 U1 10K 10K 10K 10K 10K TRIMPOT 10K 10K 2.2K 4.7K 10K 10K 10K 4.7K 10K ALC POT LM7812 30150 30150 30150 30150 30619 30150 30150 30142 30146 30150 30150 30150 30146 30267 25232 SCREEN SUPPLY BOARD A10 81950 C1 C2 C3 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 C20 C21 D1 D2 D4 D5 D6 100uF 160V 100uF 160V 100uF 160V .01uF 1KV 10uF 25V 33uF 16V 100uF 160V 10uF 50V .1uF .1uF .1uF 250V 100uF 160V .1uF 250V .01uF 10uF 25V 10uF 25V .01uF .01uF 1KV 1N5246 16V ZENER 1N756 8.2V ZENER 1A 1KV 1A 1KV 1A 1KV 23516 23516 23516 23013 23266 23308 23516 23266 23261 23261 23006 23516 23006 23260 23266 23266 23260 23013 28141 28019 28122 28122 28122 6-7 ITEM DESCRIPTION TEN-TEC PART # D7 D8 D9 D10 D11 D12 D13 D14 D15 D16 L1 Q1 Q2 Q3 Q4 Q7 Q8 R1 R2 R3 R4 R5 R6 R7 R8 R13 R14 R17 R18 R19 R20 R21 R22 R23 R24 R25 R26 R27 R28 R29 Z1 1A 1KV 1N5368 47V ZENER 1N5363 30V ZENER 1N5363 30V ZENER 1N5383 150V ZENER 1N5383 150V ZENER 1N4007 1N751 5.1V ZENER 1N4148 1N964 13V ZENER 100uH 100mA 2N4124 2N4124 MPSA92 MPSA92 2N6517 IRF830 15K 4.7K 100K 100K 10K 10K 100K 10K 12K 2W 3.3K .5W 4.7K 7W 680K .5W 680K .5W 680K .5W 680K .5W 22K 150 2W 100 OHM TRIMPOT 4.7K 7W 4.7K 7W 4.7K 7W 47 OHM 2W 10 OHM .5W MOV 28122 28136 28134 28134 28135 28135 28043 28041 28001 28010 21060 25258 25258 25107 25107 25393 25514 30076 30146 30161 30161 30150 30150 30161 30150 30324 30027 30719 30066 30066 30066 30066 30154 30407 30617 30719 30719 30719 30408 30022 30718 6-8 SWR BOARD A4 81951 ITEM DESCRIPTION TEN-TEC PART # C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14 C15 C16 C17 C18 C19 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 D14 K1 L1 L2 3-22pF .01uF .01uF 1uF 50V 1uF 50V 330pF 10pF 10pF 18pF 18pF .01uF .01uF .01uF .01uF .01uF .01uF .01uF 1000uF 35V .1uF FILM 1N4148 1N4148 1N4148 1N4148 1N4148 1N4148 1N4148 1N4148 1N4007 1N4007 1N4007 1N4148 1N4148 1N4007 REED RELAY 1mH RFC 1mH MOLDED 23169 23260 23260 23264 23264 23397 23371 23371 23373 23373 23260 23260 23260 23260 23260 23260 23260 23200 23328 28001 28001 28001 28001 28001 28001 28001 28001 28043 28043 28043 28001 28001 28043 32049 21135 21007 6-9 ITEM DESCRIPTION TEN-TEC PART # L3 L4 L5 Q1 Q2 Q3 R1 R2 R3 R4 R6 R7 R8 R9 R10 R11 R13 R14 R15 R16 R17 T1 2.2uH 15uH 1mH RFC 2N6517 2N4124 MPSA14 47 OHM 2W 330K 680 330K 10K 330K 4.7K 100K 100K 100K 10K 100K 10K 270 10K SWR XFMR 21116 21126 21135 25393 25258 25253 30408 30302 30136 30302 30150 30302 30146 30161 30161 30161 30150 30161 30150 30131 30150 85380-15 RELAY BOARD A14 81959 K1 OUTPUT RELAY RELAY PCB 32101 78270 LOAD CAP SHUNT BOARD A5 81943 C1 – C9 C10 – C12 6-10 150pF 3KV COG 150pF 3KV COG 23542 23542
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 50 Producer : AFPL Ghostscript 7.04 Creator : GSview Title : Ghostscript wrapper for C:\PROGRA~1\ghostscr\file.psEXIF Metadata provided by EXIF.tools