Testo SE and KGaA 05722034 testo Saveris 2 User Manual

Testo SE & Co. KGaA testo Saveris 2 Users Manual

Users Manual

Download: Testo SE and KGaA 05722034 testo Saveris 2 User Manual
Mirror Download [FCC.gov]Testo SE and KGaA 05722034 testo Saveris 2 User Manual
Document ID3210959
Application IDgHWxTUuvEjZa3oAIdOKdTQ==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize47.18kB (589706 bits)
Date Submitted2016-11-29 00:00:00
Date Available2016-11-29 00:00:00
Creation Date2016-11-29 10:58:09
Producing SoftwareAdobe PDF Library 9.0
Document Lastmod2016-11-29 14:30:56
Document TitleUsers Manual
Document CreatorAcrobat PDFMaker 9.1 Word 版
Document Author: quan yu

testoSaveris 2Probe User Manual
testo Saveris 2Introduction
testo Saveris 2 system is upgrading product basing on testo Saveris system. In
original system, wireless probes transfer measurement data to Saveris base
through local area network, testo professional software manages data and supply
service on data record and monitor. In Saveris 2 system, data transfer from
Internet basing on Qualcomm new Wi-Fitechnology, probes can communicate with
the cloud through wireless router. Customer can visit testo cloud anywhere and
anytime. Check real time measurement data inside his account. And can also
use APP to achieve same functions.
Testo Saveris 2 system include testo cloud and five Wi-Fi probes.
testo Saveris 2 Application

Medicine production, quality inspection and storage monitor

Building surrounding measurement and monitor

Development, laboratory, hospital surrounding measurement and monitor

Food cold chain measurement and monitor

Plant production, transfer and storage measurement and monitor
testoSaveris 2 Probes
Testo Saveris has five Wi-Fi probes:
T1, T2, T3, H1 and H2.
Saveris T1 has inside temperature sensor, can continuously measure and record
surrounding temperature and transfer to cloud website. Saveris T1 passed
EN12830 approval can use in food industrial surrounding measurement and
monitor.
Saveris T2 can support two channel external temperature probe, can continuously measure
and record surrounding temperature and transfer to cloud website. Saveris T2 passed
EN12830 approval, can use in food industrial surrounding measurement and monitor.
Saveris T3 support two channel TC probes, can continuously measure and record
surrounding temperature and transfer to cloud website.
Saveris H1 has inside temperature sensor and humidity sensor, can continuously measure
and record surrounding temperature and transfer to cloud website
Saveris H2support external testo humidity probe, can continuously measure and record
surrounding temperature and transfer to cloud website.
testo Saveris 2 Probe technical Data:
type
Saveris
measurem
ent
One inside
NTC
Measurem
ent range
T1
-30…+50°C
Saveris T2
Saveris T3
Saveris H1
Saveris H2
Two
external
NTC
Two external
TC
One inside
humidity
One
external
humidity
humidity“ 0…
100%RH
humidity:
0…100%RH
NTC:
-30…+50°C
NTC:
-30…+70°C
±2% RH,
±2% RH,
±0,5 °C
±0,5 °C
0.1°C, 0.1%,
0.1Ctd °C
0.1°C,
0.1%,
0.1Ctd °C
10minutes
Up to
external
probe
-50…+150
°C
K type TC:
-195…+1350°
J type TC:
-100…+750°C
T type TC:
-200…+400°C
±0,5 °C
±0,5 °C
accuracy
resolution
T90
response
time
± (0,5 +
0.5%mv) °C
0.1°C
0.1°C
0.1°C(-200~99
9.9),
others 1°C
40 minutes
Up to
external
probe
Up to external
probe
testo Saveris 2 Probes Specification:
type
Order
number
Operate
temperate
range
Storage
temperatur
e range
Saveris T1
0572 2001
Saveris
T2
0572 2002
Saveris
T3
0572 2003
Saveris
H1
0572 2004
Saveris
H2
0572 2005
-30 …
+50 °C
-30 … +50 °C -30 … +50 °C -30 … +50 °C -30 … +50 °C
-40 …
+70 °C
-40 … +70 °C -40 … +70 °C -40 … +70 °C -40 … +70 °C
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
5s ~ 24hour
(default
setting 15
min)
Data
memory
10000 data
per channel
10000 data
per channel
10000 data
per channel
10000 data
per channel
10000 data
per channel
LCD
display
yes
yes
yes
yes
yes
Battery life
4pcs L91
battery
2 years
4pcs L91
battery
2 years
Norm
EN12830
EN12830
------
------
------
accessory
GP AA
battery
Wall holder
lock
USB cable
GP AA
battery
Wall holder
lock
USB cable
GP AA
battery
Wall holder
lock
USB cable
GP AA
battery
Wall holder
lock
USB cable
GP AA
battery
Wall holder
lock
USB cable
Website
configurati
onactive
yes
yes
yes
yes
yes
Measurem
ent cycle
Communic
ation cycle
4pcs L91
battery
2 years
4pcs L91
battery
2 years
4pcs L91
battery
2 years
testo Saveris 2 Probes Instruction Manual
Product description:
①device
②LED
③QR code(probe serial number, cloud website adderess)
④key
⑤wall holder
⑥USB communication cable
⑦lock
First step
Inserting batteries:
 To open the battery compartment, remove two screws on battery cover by
screwdriver.
 Insert batteries (4x 1.5 V type AA). Observe the polarity!
 To close the battery compartment, tighten screws by screwdriver.
Probe Configuration
 Visit website:https://intl.saveris2.net/GoToProbe
 Enter log in page and input personal account and password
 Click and enter to Wi-Fi connecting page, click “Connect Wifi-logger”,input
wireless router SSID and password to connect into internet 。 In connect
successfully, icon
will displayed on Saveris probe LCD.
 Click “Probe” o enter configuration page. Set probe basic configuration, input
probe number, name, location, measurement cycle, communication cycle, start
time and etc.…
Alarm Setting
 Click “Alarm” and enter alarm setting page, click“Alarm configuration”,set up
alarm upper and lower limit value one by one。
Probe Management
After probe configuration, probe list can be found in Saveris system, and also
on-time measurement data, Wifi signal status, battery power status。
 Click name of probe and enter probe detailed information page which show
detailed measurement status of each channel. Click “configuration”, can enter
configuration page to modify configuration of probe.
Measurement Data transfer
After configuration finish, probe can start measurement and transfer data to cloud
side. During data transferring,icon
will be displayed on LCD.
Customer can also scan QR code on front housing of Saveris probe to visit cloud.
Question and Answers:
* battery power<5%:repalce batteries
oooo
* external probes not connected
* real value out of measurement range
FCC statements:
This device complies with part 15 of the FCC rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and (2)
this device must accept any interference received, including interference that may
cause undesired operation.
NOTE: The manufacturer is not responsible for any radio or TV interference caused
by unauthorized modifications or changes to this equipment. Such modifications or
changes could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
‐ Reorient or relocate the receiving antenna.
‐ Increase the separation between the equipment and receiver.
‐Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
‐Consult the dealer or an experienced radio/TV technician for help.
Radiation Exposure Statement:
This equipment complies with FCC/IC radiation exposure limits set forth for an
uncontrolled e nvironment. T his e quipment s hould b e i nstalled a nd o perated
with minimum distance 20cm between the radiator & your body.
Déclaration d'exposition aux radiations:
Cet éq uipement es t c onforme a ux l imites d 'exposition aux r ayonnements I C
établies pour un environnement non contrôlé. Cet équipement doit être installé
et utilisé avec u n m inimum de 20 c m de distance entre la so urce de
rayonnement et votre corps.
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is Subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux
conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2)
l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : quan yu
Create Date                     : 2016:11:29 10:58:09+08:00
Modify Date                     : 2016:11:29 14:30:56+08:00
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Metadata Date                   : 2016:11:29 14:30:56+08:00
Creator Tool                    : Acrobat PDFMaker 9.1 Word 版
Format                          : application/pdf
Creator                         : quan yu
Document ID                     : uuid:2c527a34-92be-48c6-acea-1a98362d3c50
Instance ID                     : uuid:6eec40cf-034f-4f82-89ad-2870980266e5
Producer                        : Adobe PDF Library 9.0
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WAF-05722034

Navigation menu