Texas Instruments 110LEM900 The CC110LEM-868-915 is a development tool for TIs sub 1 GHz CC110L chip. User Manual EVALUATION BOARD KIT MODULE EVM ADDITIONAL TERMS

Texas Instruments Inc. The CC110LEM-868-915 is a development tool for TIs sub 1 GHz CC110L chip. EVALUATION BOARD KIT MODULE EVM ADDITIONAL TERMS

Users Manual

Download: Texas Instruments 110LEM900 The CC110LEM-868-915 is a development tool for TIs sub 1 GHz CC110L chip. User Manual EVALUATION BOARD KIT MODULE  EVM  ADDITIONAL TERMS
Mirror Download [FCC.gov]Texas Instruments 110LEM900 The CC110LEM-868-915 is a development tool for TIs sub 1 GHz CC110L chip. User Manual EVALUATION BOARD KIT MODULE  EVM  ADDITIONAL TERMS
Document ID2131570
Application ID1LeCGy3qAdvziIx7fIdWkA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize113.87kB (1423409 bits)
Date Submitted2013-12-02 00:00:00
Date Available2013-12-02 00:00:00
Creation Date2013-10-28 17:20:53
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2013-10-28 17:20:53
Document TitleEVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Document CreatorMicrosoft® Word 2010
Document Author: Magnus Wines

SWRU292B
October 2013
CC11xL 868/915 MHz Development Kit Quick Start Guide
Opening the Box and Running the Packet Error Rate Test
1. Kit Contents
2. TrxEB Overview
Power
Selection
EM
Breakout
3. Plug the EM into the TrxEB
Board Mode
Switches
EM
Connectors
Main
Power
Switch
USB
2 x SmartRF™ Transciever EB (TrxEB)
2 x CC110LEM 868/915 MHz
1 x CC113LEM 868/915 MHz
1 x CC115LEM 868/915 MHz
1 x MSP430 Debug Probe (FET)
2 x Micro USB Cables
1 x Standard USB Cable
1 x 14-pin Flat Cable
Insert a CC110LEM into the TrxEB. Do not use
excessive force on the EM.
MSP430
Debug
Interface
MSP430
Breakout
The 868/915 MHz RF boards in this kit are FCC and IC certified
and tested to comply with ETSI/R&TTE over temperatures from
0 to +35°C.
LCD
Buttons
The EM has a PCB antenna, so there is no need
for an external antenna.
LEDs
You can also use CC113L and CC115L for the Per
test, but note that CC113L is a receiver only and
Caution! The kit contains ESD sensitive CC115L is a transmitter only.
FCC/IC Regulatory Compliance
FCC Part 15 Class A Compliant
IC ICES-003 Class A Compliant
components. Handle with
prevent permanent damage.
care
to
(* picture may deviate)
4. Select Board Mode
5. Power Options
Use the switches S1 and S2 to select the operating
mode of the board. For the sake of this quick start
guide, please select “Enable” and “UART”. This
configuration will make it possible to communicate
directly with the MSP430 over a virtual COM port
on the PC.
There are several ways of applying power to the
TrxEB.




6. Select Power Source
2 x 1.5V AA Non-Rechargeable Alkaline
Batteries
USB (5V through USB plug)
External Power Supply (requirements below)
MSP430 Debugger
When the power source is batteries or USB, the
voltage regulators on the TrxEB will set the on- Depending on the power source, make sure you
board supply voltage to 3.3VDC.
connect jumpers to the appropriate pins on the
“Power Source” header. For instance, if you use
External Power Supply Requirements:
batteries, use a jumper to short-circuit pin 1 and 2
Nom Voltage: 3.3VDC
on the header. The last jumper in the row (pin 9Max Current: 800 mA
10) should always be mounted, unless the
Efficiency Level V
MSP430 FET is used as the power source.
Warning! To minimize risk of personal injury or Note that there should only be one active
property damage, never use rechargeable power source at any one time. Do not leave the
batteries to power the board.
board powered when unattended.
7. Welcome Screen
8. Packet Error Rate Test
9. Select Test Mode
Turn on power with the Main Power switch. You
should now see the Texas Instruments logo and a
short description of the buttons on the LCD.
Pushing any of the five buttons on the board will
take you to the main menu.
Select the PER (Packet Error Rate) test by
highlighting the selection using the up/down
buttons. Confirm your selection by pressing Enter
(right button).
The PER test can be run is several modes. Easy
Mode sets up a one-way test and uses default
settings. This test is convenient for practical range
testing.
The other test modes are described in the “TrxEB
RF PER Test Software Example User’s Guide”,
available on the kit web page.
NB! If you don’t see anything on the screen
make sure the mode switches are in the correct
positions (see step 4 above).
To proceed, highlight “Easy Mode” and press Enter
(right button).
When using an external power supply, make sure it meets the listed requirements in addition to complying with applicable regional product regulatory and
safety certification requirements such as UL, CSA, VDE, CCC, and PSE.
Web sites:
E2E Forum:
www.ti.com/lprf
www.ti.com/lprf-forum
Make sure to subscribe to the Low-Power RF
Newsletter to receive information about updates to
documentation, new product releases, and more.
Sign up on the TI web pages.
10. Select Frequency
11. Select Mode
12. Establish Link
One of the boards must operate as the slave The slave node will now wait for a configuration
(transmitter) and the other as master (receiver). package from the Master. The configuration
Select Slave on one board…
contains the parameters used for the PER test.
…and Master on the other board.
The configuration package will be sent when you
select “link devices” on the master node.
14. Start the Receiver (master)
15. PER Test Results
Select which frequency to use for the test. Make
sure that the evaluation modules you have match
the selected frequency.
13. Link Established
When the initial linking has completed, the slave On the master node, you can select the number of The master will display a window that plots the
node will start the test by continuously transmitting packets you want to receive in order to calculate received signal strength (RSSI) for each packet.
packets to the master.
the packet error.
When selecting “Start PER Test”, the master Press the “Up” button to go to the detailed
(receiver) will begin to count the number of statistical window.
received packets and provide some statistics.
16. PER Test Results
17. Troubleshooting
18. References
It you are experiencing problems with this test,
please check the following:
Please visit www.ti.com and
The statistics window will show the error rate
based on the number of lost or erroneous packets
divided by the total number of packets that should 
have been received.


Nothing is shown in the display! Make sure the http://www.ti.com/tool/cc11xldk-868-915
mode switches are in the correct positions (see
On the kit product page, you will find additional
step 4 above).
documentation, links to updated software
Please visit the kit web page and check for examples and software tools like SmartRF Studio.
updated SW and documentation. Updated SW
can be downloaded to the device using IAR You will also find a lot of information on the TI E2E
forum at http://e2e.ti.com
EW430 or SmartRF Flash Programmer.
If you get poor PER results at short distances,
try to move the transmitter and receiver further We hope that you will enjoy working with the
apart. The CC11xL receiver may experience CC110L, CC113L and CC115L devices.
saturation if it is too close to the other CC11xL
transmitting at full output power.
SmartRF™ Studio
1. Download and Install
2. Launch SmartRF Studio
3. Test the Radio
Before connecting SmartRF TrxEB to your PC,
download and install SmartRF Studio from
www.ti.com/smartrfstudio.
After installing the tool, connect the EB to the PC You can now configure the radio, export register
using the USB cable and start SmartRF Studio. settings and run performance tests of the radio.
Select the “Sub 1 GHz” tab and double click the
highlighted device icon (CC110L, CC113L or
CC115L).
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:
The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims
arising from the handling or use of the goods.
Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days from
the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO
BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF
MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH
ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES.
Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This
notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety
programs, please visit www.ti.com/esh or contact TI.
No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or
combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and
therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,
software performance, or infringement of patents or services described herein.
REGULATORY COMPLIANCE INFORMATION
As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal
Communications Commission (FCC) and Industry Canada (IC) rules.
For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,
DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer
use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing
devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency
interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will
be required to take whatever measures may be required to correct this interference.
General Statement for EVMs including a radio
User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and
power limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local
laws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate this
radio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited and
unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory
authorities, which is responsibility of user including its acceptable authorization.
For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant
Caution
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the
equipment.
FCC Interference Statement for Class A EVM devices
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial
environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to
cause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
For EVMs annotated as IC – INDUSTRY CANADA Compliant
This Class A or B digital apparatus complies with Canadian ICES-003.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Concerning EVMs including radio transmitters
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this
device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
Concerning EVMs including detachable antennas
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should
be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum
permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain
greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.
Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de
l'utilisateur pour actionner l'équipement.
Concernant les EVMs avec appareils radio
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain
maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à
l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente
(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel
d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans
cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
【Important Notice for Users of EVMs for RF Products in Japan】
】
This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan
If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:
1.
2.
3.
Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and
Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of
Japan,
Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this
product, or
Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with
respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note
that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.
Texas Instruments Japan Limited
(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan
http://www.tij.co.jp
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】
本開発キットは技術基準適合証明を受けておりません。
本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。
1.
2.
3.
電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。
実験局の免許を取得後ご使用いただく。
技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。
日本テキサス・インスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
http://www.tij.co.jp
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
SPACER
EVALUATION BOARD/KIT/MODULE (EVM)
WARNINGS, RESTRICTIONS AND DISCLAIMERS
For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished
electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in
laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks
associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end
product.
Your Sole Responsibility and Risk. You acknowledge, represent and agree that:
1.
2.
3.
4.
You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug
Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,
affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.
You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable
regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,
contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)
between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to
minimize the risk of electrical shock hazard.
Since the EVM is not a completed product, it may not meet all applicable regulatory and safety compliance standards (such as UL,
CSA, VDE, CE, RoHS and WEEE) which may normally be associated with similar items. You assume full responsibility to determine
and/or assure compliance with any such standards and related certifications as may be applicable. You will employ reasonable
safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to
perform as described or expected.
You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.
Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the
user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and
environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact
a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the
specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or
interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the
load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures
greater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components include
but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the
EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please
be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable
in electronic measurement and diagnostics normally found in development environments should use these EVMs.
Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives
harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in
connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims
arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.
Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such
as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices
which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate
Assurance and Indemnity Agreement.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2013, Texas Instruments Incorporated

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Page Count                      : 6
XMP Toolkit                     : 3.1-701
Part                            : 1
Conformance                     : B
Producer                        : Microsoft® Word 2010
Keywords                        : SSZZ027E
Creator Tool                    : Microsoft® Word 2010
Create Date                     : 2013:10:28 17:20:53+01:00
Modify Date                     : 2013:10:28 17:20:53+01:00
Title                           :  EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS
Creator                         : Magnus Wines
Description                     : Important Notice
Author                          : Magnus Wines
Subject                         : Important Notice
EXIF Metadata provided by EXIF.tools
FCC ID Filing: ZAT110LEM900

Navigation menu