Texas Instruments 1111USB900 The CC1111Dongle-868 is a development tool for TIs sub 1 GHz CC1111 chip User Manual

Texas Instruments Inc. The CC1111Dongle-868 is a development tool for TIs sub 1 GHz CC1111 chip

User manual

    SWRU328     December 2012   CC1111 USB Evaluation Kit 868/915 MHz Quick Start Guide  1. Kit Contents     1 x CC1111 USB Dongle (CC1111Dongle-868)    This Quick Start Guide  The hardware in this kit is FCC and IC  certified  and  complies  with ETSI/R&TTE  requirements  over temperature from 0 to +35°C. 2. Getting Started  The  CC1111  USB  Dongle  can  be used as a development platform for USB and RF applications.  An  external  development  board  or debugger,  like  the  CC  Debugger, SmartRF04EB or SmartRF05EB, is required  to  program  and  debug software running on the CC1111.  Note that the CC1111 USB Dongle is pre-programmed with the packet sniffer firmware.  This  Quick  Start  Guide  will describe how  to  use  the  dongle with the packet sniffer and what would  be  the  next  steps  for developing your own software. 3. Preparations  Before  proceeding,  please download  and  install  the  following tools:  SmartRF Flash Programmer www.ti.com/tool/flash-programmer   You  will  need  this  tool  to  program the packet capture firmware on the CC1111 USB dongle  SmartRF Packet Sniffer www.ti.com/packetsniffer   This  is  the  PC  tool  that  displays and parses the packets received by the capture device.  4. Programming the Dongle  For the USB dongle to operate as a packet  capture  device,  it  must  be programmed with the packet sniffer firmware.  By  default,  the  dongle comes  pre-programmed  with  this firmware.  Connect  the  USB  dongle  to  the debugger  or  the  development board  with  an  appropriate  10  pin flat cable. The dongle must also be powered via the USB bus. Refer to picture below for an example.     Caution!  Avoid  using  other  power sources  for  the  dongle  than  a regular USB voltage source at max 5.5V, 500 mA.  5. Programming the Dongle  Launch  the  SmartRF  Flash Programmer  and  make  sure  you select  the  “System-on-Chip”  tab. The  tool  should  show  a  line  with CC1111  connected  to  a SmartRF04EB.  Next, locate the flash image sniffer_fw_ccxx11.hex in  “C:\Program Files\Texas Instruments\SmartRF Tools\Packet Sniffer\bin\general\firmware”    Select  “Erase,  program  and  verify” and  press  the  “Perform  Actions” button.  6. Install USB Driver  After  programming  the  device, disconnect  the  dongle  from  the programming board and plug it into the  PC.  Windows’  new  hardware wizard will appear.   Select  the  options  for  automatic installation  and  wait  for  the  driver installation  to  complete.  If  the Wizard  asks  for  a  specific  driver, point it to the cebal2.inf file located in “C:\Program  Files\Texas  Instruments\SmartRF Tools\Drivers\cebal\win_<arch-specific>\”   After  installation  of  the  driver,  the Packet  Sniffer  capture  device  is ready for use.
  Web sites:  www.ti.com/lprf E2E Forum:  www.ti.com/lprf-forum Make  sure  to  subscribe  to  the  Low-Power  RF Newsletter  to  receive  information  about  updates  to documentation,  new  product  releases,  and  more. Sign up on the TI web pages.  7. Packet Sniffer (1)  Launch the Packet Sniffer. A dialog will  request  the  user  to  select  a protocol.  The  CC1111  capture device  can  be  used  with  the SimpliciTI  or  the  Generic  (no parsing)  protocols.  A  new  window will appear.    The  USB  dongle  should  be  listed with chip type CC1111 and EB type CC1111  USB  dongle  in  the “Capturing Device” tab.   Highlight the device to make it your capture device.  8. Packet Sniffer (2)  Next,  select  the  Radio Configuration  tab  and  make  sure the  radio  registers  on  the  device are  set  according  to  the  format  of the radio signals you are sniffing.     If this  is the first time  you use  the tool,  press  the  browse  button  to locate a .prs file with packet sniffer register settings for CC1111.   You  can  generate  your  own  .prs files  with  the  “Register  Export” function in SmartRF Studio  9. Packet Sniffer (3)  Finally,  press  the  small “play”  icon on  the  tool  bar  to  start  sniffing packets.  If  there  are  radio  packets  on  the air,  and  the  CC1111  has  the appropriate  radio  settings,  the captured packets  will be displayed in  the  packet  sniffer  display window.    Enjoy! 10. Developing USB Software  A  good  start  for  developing  your own  USB  application  for  the CC1111 USB dongle would be the “CC  USB  Firmware  Library  and Examples” software package.  The  Library  contains  a  complete USB  framework  that  allows  the user  to  develop  any  USB  device type.  Examples  showing implementations  of  a  HID  device and a CDC device are included.  The  software  can  be  downloaded from the CC1111EMK web page or directly from www.ti.com/lit/zip/swrc088  11. Development Tools  The  preferred  tool  for  developing software for CC1111 and for single stepping  and  debugging  is  IAR Embedded Workbench for 8051.    A  free,  code  size  limited  version can be  downloaded  from the web. See www.iar.com/ew8051  12. Thank You!  We  hope  you  will  enjoy  working with  the  CC1111  device  and related  Low-Power  RF  products from Texas Instruments.    The  Low  Power  RF  Online Community  has forums, blogs and videos.  Use  the  forums  to  find information,  discuss  and  get  help with  your  design.  Join  us  at www.ti.com/lprf-forum             Caution! The kit contains ESD sensitive components. Handle with care to prevent permanent damage. To minimize risk of injury, avoid touching components during operation if symbolized as hot.
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMSTexas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claimsarising from the handling or use of the goods.Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days fromthe date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TOBUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTHABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIALDAMAGES.Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. Thisnotice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safetyprograms, please visit www.ti.com/esh or contact TI.No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, orcombination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, andtherefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,software performance, or infringement of patents or services described herein.REGULATORY COMPLIANCE INFORMATIONAs noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the FederalCommunications Commission (FCC) and Industry Canada (IC) rules.For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumeruse. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computingdevices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequencyinterference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense willbe required to take whatever measures may be required to correct this interference.General Statement for EVMs including a radioUser Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency andpower limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with locallaws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate thisradio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited andunauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatoryauthorities, which is responsibility of user including its acceptable authorization.For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 CompliantCautionThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not causeharmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate theequipment.FCC Interference Statement for Class A EVM devicesThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely tocause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devicesThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipmentgenerates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.For EVMs annotated as IC – INDUSTRY CANADA CompliantThis Class A or B digital apparatus complies with Canadian ICES-003.Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate theequipment.Concerning EVMs including radio transmittersThis device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) thisdevice may not cause interference, and (2) this device must accept any interference, including interference that may cause undesiredoperation of the device.Concerning EVMs including detachable antennasUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gainapproved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain shouldbe so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximumpermissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gaingreater than the maximum gain indicated for that type, are strictly prohibited for use with this device.Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité del'utilisateur pour actionner l'équipement.Concernant les EVMs avec appareils radioLe présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation estautorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.Concernant les EVMs avec antennes détachablesConformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gainmaximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique àl'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manueld’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus danscette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.SPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
【【Important Notice for Users of this Product in Japan】】This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of JapanIf you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:1. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs andCommunications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law ofJapan,2. Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to thisproduct, or3. Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan withrespect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please notethat if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.Texas Instruments Japan Limited(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japanhttp://www.tij.co.jp【ご使用にあたっての注】本開発キットは技術基準適合証明を受けておりません。本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。1. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。2. 実験局の免許を取得後ご使用いただく。3. 技術基準適合証明を取得後ご使用いただく。なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。   上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。日本テキサス・インスツルメンツ株式会社東京都新宿区西新宿6丁目24番1号西新宿三井ビルhttp://www.tij.co.jpSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
EVALUATION BOARD/KIT/MODULE (EVM)WARNINGS, RESTRICTIONS AND DISCLAIMERSFor Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finishedelectrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation inlaboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risksassociated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished endproduct.Your Sole Responsibility and Risk. You acknowledge, represent and agree that:1. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and DrugAdministration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.2. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicableregulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents tominimize the risk of electrical shock hazard.3. You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, evenif the EVM should fail to perform as described or expected.4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per theuser guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, andenvironmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contacta TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of thespecified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/orinterface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to theload specification, please contact a TI field representative. During normal operation, some circuit components may have case temperaturesgreater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components includebut are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using theEVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, pleasebe aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeablein electronic measurement and diagnostics normally found in development environments should use these EVMs.Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representativesharmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or inconnection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claimsarise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (suchas life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as deviceswhich are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separateAssurance and Indemnity Agreement.Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2012, Texas Instruments Incorporated