Texas Instruments 2510EM The CC2510EM is a development tool for TIs 2.4 GHz CC2510 proprietary System-on-Chip User Manual CC2510 CC2511DK Quick Start

Texas Instruments Inc. The CC2510EM is a development tool for TIs 2.4 GHz CC2510 proprietary System-on-Chip CC2510 CC2511DK Quick Start

User Manual

 September 2013  Web sites:  www.ti.com/lprf E2E Forum:  www.ti.com/lprf-forum Make sure to subscribe to the Low-Power RF Newsletter to receive information about updates to documentation, new product releases and more. Sign up on the TI web pages.   CC2510EMK Quick Start Guide  Opening the box an running the Packet Error Rate Test on SmartRF04EB  1. Kit Contents   2 x CC2510EM 2 x Pulse W1010 2.4GHz antennas  The  boards  in  this  kit  are  FCC  and  IC certified  and  are  tested  to  comply  with ETSI/R&TTE  over  temperatures  from  0  to +35°C.  FCC/IC Regulatory Compliance FCC Part 15 Class A Compliant IC ICES-003 Class A Compliant 2. How to use the modules  The  EMK  is  an  add-on  kit  to  supplement  the CC2510DK  with  evaluation  boards  supporting additional frequency bands.  The CC2510EM boards can be plugged into several development  boards  from  Texas  Instruments.  Most notably,  you  can  use  the  SmartRF04EB,  which  is included in the CC2510-CC2511DK. This board lets you  run  a  packet  error  rate  (PER)  test,  control  the device from SmartRF™ Studio and it can be used as a development platform.  It  is  also  possible  to  plug  the  EM  into  the SmartRF05EB  or  the  “SoC  Battery  Board”.  The SmartRF05EB, or the SoC BB together with the CC Debugger,  will  provide  a  complete  development environment for the CC2510. See:  http://www.ti.com/tool/soc-bb  This  guide  will  show  how  to  use  the  modules together with SmartRF04EB.  3. Plug EM into EB   Insert a CC2510EM into both SmartRF04EBs. Make sure  the  antenna  is  firmly  connected  to  the  SMA connector.   Caution! The kit contains ESD sensitive components. Handle with care to prevent permanent  damage.  To  minimize  risk  of injury, avoid touching components during operation if symbolized as hot.  4a. Battery power    There  are  three  different  ways  of  applying power to the EB:  The  first  method  involves  using  a  battery, either  a  9V  or  a  4xAA  battery  pack connected  to  the  battery  connector  on  the bottom side of the board  Warning! To minimize risk of personal injury or property damage, never use rechargeable batteries to power the board. 4b. DC power    The second method applies DC power using the DC input  jack  (right  in  picture,  centre  is  +,  sleeve  is ground),  or  by  connecting  a  4-10V  voltage  source between  the  4-10V  and  0V  terminals  of  the  power connector  (left  in  picture).  It  is  also  possible  to connect a 3.3V voltage source between the 3.3V and 0V terminals. The on-board voltage regulators will be bypassed in this case.  External Power Supply1 Requirements: Nom Voltage: 6 VDC Max Current: 800 mA Efficiency Level V  4c. USB power    The  EB  can  also  be  powered  from  the  USB  bus. Make  sure  that  the  SmartRF™  Studio  software  is installed  before  connecting  the  EB  to  the  PC; otherwise you may experience problems in installing it later due to driver issues.  Note  that  if  multiple  power  sources  are  connected, the  source  with  the  highest  voltage  will  power  the EB. This means that you should disconnect any attached battery when using a lab supply or USB power; otherwise the battery will be drained.  5. Set power switch    If a 3.3V source  is used as described in 4b above,  the  switch  should  be  set  to  the leftmost  position.  For  all  other  cases,  the switch  should  be  set  to  the  rightmost position. This switch can be used to turn off the  EB  by  switching  it  to  the  opposite position of that used to turn it on  Do  not  leave  the  board  powered  when unattended. 6. Packet error rate test  When  power  is  applied  to  the  board,  the  test program will start. You should see the Chipcon logo with  chip  name  and  revision  number  as  shown above  on  the  LCD  display  on  both  EBs.  Pushing button S1 in the lower right corner of the board will show the first menu item. 7. Select Frequency  Select  the  frequency  that  you  want  to  use  (2420 MHz, 2440 MHz, 2460 MHz or 2480 MHz). Move the joystick up or down to display the choices and push button  S1  in  the  lower  right  corner  of  the  board  to select the displayed frequency.                                         1 When using an external power supply, make sure it meets the listed requirements in addition to complying with applicable regional product regulatory and safety certification requirements such as UL, CSA, VDE, CCC, and PSE
 September 2013  Web sites:  www.ti.com/lprf E2E Forum:  www.ti.com/lprf-forum Make sure to subscribe to the Low-Power RF Newsletter to receive information about updates to documentation, new product releases and more. Sign up on the TI web pages.  8. Select Data Rate  Select which data rate to use (10 kbps, 250 kbps or  500  kbps)  by  moving  the  joystick.  Confirm your choice by pushing button S1.  9. EB 1: Select Receiver  Select  Receiver  on  the  first  EB  by  moving  the joystick.  Confirm  by  pressing  button  S1.  The Receiving node will display “Ready to receive”. 10. EB 2: Select Transmitter  Select Transmitter  on the  other  EB by moving the joystick upward. Confirm by pressing button S1.  11. EB 2: Number of packets  On  the  transmitter  EB,  select  the  number  of packets  to send. More packets  take longer,  but give  a  better  statistical  result.  Confirm  by pressing button S1.  12. PER Test (Transmitter)  Press  S1  button  again  to  start  transmitting  the packet  burst. The transmitter will  show  a running counter that shows the number of packets sent.  13. PER Test (Receiver)  The receiver will show the total accumulated packet error  rate  (PER)  together  with  the  average  signal strength  (RSSI)  of  the  previous  32  received packets.  A  symbol  in  the  upper  right  corner  will blink  for  every  32nd incoming  packet  to  indicate whether the link is maintained.  14. Per Test results  When the PER test is completed, the result will be displayed on the receiver until a new test  is started.  A  new  test  can  be  started  from  the transmitter. 15. References Please visit www.ti.com and   http://www.ti.com/tool/cc2510emk   For  more  information  about  how  to  use  the CC2510EM,  download  the  CC2510-CC2511DK User  Manual,  the  SmartRF™  Studio  PC  Tool, software  examples,  as  well  as  datasheets, reference designs and application notes.  You will also find a lot of information on the TI E2E forum at http://e2e.ti.com   We hope that  you will enjoy working with  the CC2510 device. 16. Troubleshooting It you are experiencing problems with this test, please check the following:  a.  The data rate affects the obtainable link range. b.  The source code for the packet error rate test application is available on the web. You may modify the source code to test at other frequencies or data rates. c. See “DN300 -- SmartRF04EB Troubleshooting” for general troubleshooting of your EB board.   SmartRF™ Studio  1. Download and Install    Before  connecting  SmartRF04EB  to  your  PC, download  SmartRF  Studio  from www.ti.com/smartrfstudio.  2. Launch SmartRF Studio    After  installing  the tool, connect  the  EB  to  the  PC using  the  USB  cable  and  start  SmartRF  Studio. Select  the  “2.4  GHz”  tab  and  double  click  the CC2510 device icon. 3. Configure the Radio    You  can  now  configure  the  radio,  run  tests, export  register  settings  and  run  link  tests  with another  CC2510  on  a  SmartRF04EB  connected to the PC.
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMSTexas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claimsarising from the handling or use of the goods.Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days fromthe date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TOBUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTHABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIALDAMAGES.Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. Thisnotice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safetyprograms, please visit www.ti.com/esh or contact TI.No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, orcombination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, andtherefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,software performance, or infringement of patents or services described herein.REGULATORY COMPLIANCE INFORMATIONAs noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the FederalCommunications Commission (FCC) and Industry Canada (IC) rules.For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumeruse. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computingdevices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequencyinterference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense willbe required to take whatever measures may be required to correct this interference.General Statement for EVMs including a radioUser Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency andpower limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with locallaws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate thisradio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited andunauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatoryauthorities, which is responsibility of user including its acceptable authorization.For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 CompliantCautionThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not causeharmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate theequipment.FCC Interference Statement for Class A EVM devicesThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely tocause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devicesThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipmentgenerates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.For EVMs annotated as IC – INDUSTRY CANADA CompliantThis Class A or B digital apparatus complies with Canadian ICES-003.Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate theequipment.Concerning EVMs including radio transmittersThis device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) thisdevice may not cause interference, and (2) this device must accept any interference, including interference that may cause undesiredoperation of the device.Concerning EVMs including detachable antennasUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gainapproved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain shouldbe so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximumpermissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gaingreater than the maximum gain indicated for that type, are strictly prohibited for use with this device.Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité del'utilisateur pour actionner l'équipement.Concernant les EVMs avec appareils radioLe présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation estautorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.Concernant les EVMs avec antennes détachablesConformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gainmaximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique àl'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manueld’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus danscette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.SPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
【【Important Notice for Users of EVMs for RF Products in Japan】】This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of JapanIf you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:1. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs andCommunications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law ofJapan,2. Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to thisproduct, or3. Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan withrespect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please notethat if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.Texas Instruments Japan Limited(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japanhttp://www.tij.co.jp【無線電波を送信する製品の開発キットをお使いになる際の注意事項】本開発キットは技術基準適合証明を受けておりません。本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。1. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。2. 実験局の免許を取得後ご使用いただく。3. 技術基準適合証明を取得後ご使用いただく。なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。   上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。日本テキサス・インスツルメンツ株式会社東京都新宿区西新宿6丁目24番1号西新宿三井ビルhttp://www.tij.co.jpSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
EVALUATION BOARD/KIT/MODULE (EVM)WARNINGS, RESTRICTIONS AND DISCLAIMERSFor Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finishedelectrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation inlaboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risksassociated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished endproduct.Your Sole Responsibility and Risk. You acknowledge, represent and agree that:1. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and DrugAdministration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.2. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicableregulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents tominimize the risk of electrical shock hazard.3. Since the EVM is not a completed product, it may not meet all applicable regulatory and safety compliance standards (such as UL,CSA, VDE, CE, RoHS and WEEE) which may normally be associated with similar items. You assume full responsibility to determineand/or assure compliance with any such standards and related certifications as may be applicable. You will employ reasonablesafeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail toperform as described or expected.4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per theuser guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, andenvironmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contacta TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of thespecified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/orinterface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to theload specification, please contact a TI field representative. During normal operation, some circuit components may have case temperaturesgreater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components includebut are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using theEVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, pleasebe aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeablein electronic measurement and diagnostics normally found in development environments should use these EVMs.Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representativesharmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or inconnection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claimsarise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (suchas life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as deviceswhich are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separateAssurance and Indemnity Agreement.Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2013, Texas Instruments Incorporated

Navigation menu