Texas Instruments 2520EM The CC2520EM is a development tool for Texas Instruments 2.4 GHz CC2520 IEEE 802.15.4 transceiver. User Manual

Texas Instruments Inc. The CC2520EM is a development tool for Texas Instruments 2.4 GHz CC2520 IEEE 802.15.4 transceiver.

user manual

SWRU139    CC2520 Development Kit Quick Start Guide  1. Kit Contents    3 x SmartRF05 Evaluation Boards 2 x MSP430F2618 Sandwich Boards 3 x CC2520 Evaluation Modules  3 x Pulse W1010 antennas 1 x MSP430 Debugger Cables & Documentation  The  CC2520EM  in  this  kit  is  FCC/IC certified  and  complies  with  ETSI/R&TTE over temperature from 0 to +35°C.   The  antenna,  W1010  from  Pulse,  is  a  ¼ wave dipole antenna with 2 dBi gain.  FCC/IC Regulatory Compliance FCC Part 15 Class A Compliant IC ICES-003 Class A Compliant  2. Assemble the Boards   Insert  the  MSP430  sandwich  boards (called  CCMSP-EM430F2618)  into  the SmartRF05EBs. Connect antennas to both of  the  CC2520EM.  Make  sure  the antennas  are  firmly  attached  to  the  SMA connector. If not, RF performance may be reduced.  Insert  the  CC2520EM  into  the MSP430  board.  Do  not  use  excessive force when assembling the boards.    Caution! The kit contains ESD  sensitive components. Handle with care to prevent permanent  damage.  To  minimize  risk  of injury, avoid touching components during operation if symbolized as hot.  3. Power Options  There are several ways of applying power to the SmartRF05EB;    USB (5V through USB plug)   External Power Supply (requirements below)   2 x 1.5V AA Non-Rechargeable Alkaline Batteries  Voltage  regulators  on  the  SmartRF05EB will set the on-board voltage to 3.3V.  External Power Supply1 Requirements: Nom Voltage: 4 to 20 VDC Max Current: 1500 mA Efficiency Level V   Warning!  To  minimize  risk  of  personal injury  or  property  damage,  never  use rechargeable batteries to power the board.    There  should  only  be  one active power source connected to the board at any time.  4. Select Power Source  Locate  the power  source header  P11 just  above  the LCD  on  the SmartRF05EB Connect  pins  1  and  2  if  you  are  using batteries to power the board. Connect pins 2 and  3 if  you  are using  USB  or external power supply.  Once you have set  P11,  find switch  P8  just next  to  the  DC jack  on  the SmartRF05EB. To  power  on the  board,  flip  the  switch  form  “OFF”  to “ON”.  Do not leave the EVM powered when unattended.  5. Packet Error Rate Tester    When power is turned on, the Packet Error Rate  Test  program,  which  is preprogrammed  on the  MSP430, will  start running.   The  LCD  should  display  the  screen  as shown in the picture above. Press Button 1 to enter the menu.   6. Set Channel    Select  a  channel  between  11  and  26 (2405-2480 MHz). The channel is selected by pushing the joystick to the right or left. Confirm the selection by pressing Button 1.                                                       1 When using an external power supply, make sure it meets the listed requirements in addition to complying with applicable regional product regulatory and safety certification requirements such as UL, CSA, VDE, CCC, and PSE.
SWRU139   7. Select Transmitter/Receiver    Select  transmitter  on  one  of  the SmartRF05EB’s and  receiver on  the  other by navigating with the joystick. Confirm the selection  by  pressing  Button  1  on  both devices.  The  receiver  is  now  ready  to receive packets. 8. Select Output Power     On  the  transmitter  node,  selection  of  TX output  power  and  burst  size  (number  of packets to send) is also needed. Select TX output  power  by  navigating  the  joystick, either  -4  dBm,  0  dBm  or  4  dBm,  and confirm with Button 1.   9. Select Burst Size    Select burst size by navigating the joystick, either  1000,  10K,  100K  or  1M  packets. Confirm the selection with Button 1.     10. PER Test Transmitter    The  transmitter  is  now  configured  for  the PER  test.  The  PER  test  is  started  by moving the joystick UP. The transmitter will display the number of packets sent during the PER test. The PER test is stopped by moving the joystick UP again. 11. PER Test Receiver    The PER test receiver will display the total PER  (calculated  based  on  the  received sequence  numbers),  and  moving  average RSSI  value  on  the  display.  It  will  also display  the  number  of  packets  received during the PER test. 12. Download Your Own SW  In order to program the MSP430 MCU on the  CCMSP-EM430F2618  board  the MSP430  Debug  Interface  is  needed. Connect  the  MSP430  debug  interface  to JTAG  connector  P12  on  the  CCMSP-EM430F2618. Connect the debug interface to the PC with a USB cable.  Use either MSP430 Flasher, CCS or IAR to download your code.  13. SmartRF Studio    In order to use SmartRF Studio to control the CC2520 radio, the CC2520EM should be  connected  directly  to  the SmartRF05EB.   SmartRF Studio  can  be  downloaded from www.ti.com/smartrfstudio.  14. Documentation  Hardware A  comprehensive  description  of  the hardware  included  in  the  CC2520 development kit is found in the CC2520DK User's Manual.   Software The  PER  tester  and  other  software examples are documented in the CC2520 Software  Examples  User's  Guide.  This document also describes how to download the  application  to  the  MSP430  on  the CCMSP-EM430F2618 board.  Kit website The  user  manuals  are  found  on  the CC2520DK website: http://www.ti.com/tool/cc2520dk
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMSTexas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claimsarising from the handling or use of the goods.Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/kit may be returned within 30 days fromthe date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TOBUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OFMERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTHABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIALDAMAGES.Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. Thisnotice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safetyprograms, please visit www.ti.com/esh or contact TI.No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, orcombination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, andtherefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design,software performance, or infringement of patents or services described herein.REGULATORY COMPLIANCE INFORMATIONAs noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the FederalCommunications Commission (FCC) and Industry Canada (IC) rules.For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT,DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumeruse. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computingdevices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequencyinterference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense willbe required to take whatever measures may be required to correct this interference.General Statement for EVMs including a radioUser Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency andpower limits. Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with locallaws governing radio spectrum allocation and power limits for this evaluation module. It is the user’s sole responsibility to only operate thisradio in legally acceptable frequency space and within legally mandated power limitations. Any exceptions to this are strictly prohibited andunauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatoryauthorities, which is responsibility of user including its acceptable authorization.For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 CompliantCautionThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not causeharmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate theequipment.FCC Interference Statement for Class A EVM devicesThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely tocause harmful interference in which case the user will be required to correct the interference at his own expense.
FCC Interference Statement for Class B EVM devicesThis equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipmentgenerates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may causeharmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. Ifthis equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off andon, the user is encouraged to try to correct the interference by one or more of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.For EVMs annotated as IC – INDUSTRY CANADA CompliantThis Class A or B digital apparatus complies with Canadian ICES-003.Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate theequipment.Concerning EVMs including radio transmittersThis device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) thisdevice may not cause interference, and (2) this device must accept any interference, including interference that may cause undesiredoperation of the device.Concerning EVMs including detachable antennasUnder Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gainapproved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain shouldbe so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximumpermissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gaingreater than the maximum gain indicated for that type, are strictly prohibited for use with this device.Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité del'utilisateur pour actionner l'équipement.Concernant les EVMs avec appareils radioLe présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation estautorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter toutbrouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.Concernant les EVMs avec antennes détachablesConformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gainmaximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique àl'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente(p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manueld’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus danscette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.SPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
【【Important Notice for Users of EVMs for RF Products in Japan】】This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of JapanIf you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:1. Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs andCommunications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law ofJapan,2. Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to thisproduct, or3. Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan withrespect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please notethat if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.Texas Instruments Japan Limited(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japanhttp://www.tij.co.jp【無線電波を送信する製品の開発キットをお使いになる際の注意事項】本開発キットは技術基準適合証明を受けておりません。本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。1. 電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。2. 実験局の免許を取得後ご使用いただく。3. 技術基準適合証明を取得後ご使用いただく。なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。   上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。日本テキサス・インスツルメンツ株式会社東京都新宿区西新宿6丁目24番1号西新宿三井ビルhttp://www.tij.co.jpSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACERSPACER
EVALUATION BOARD/KIT/MODULE (EVM)WARNINGS, RESTRICTIONS AND DISCLAIMERSFor Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finishedelectrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation inlaboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risksassociated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished endproduct.Your Sole Responsibility and Risk. You acknowledge, represent and agree that:1. You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and DrugAdministration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees,affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.2. You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicableregulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates,contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical)between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents tominimize the risk of electrical shock hazard.3. Since the EVM is not a completed product, it may not meet all applicable regulatory and safety compliance standards (such as UL,CSA, VDE, CE, RoHS and WEEE) which may normally be associated with similar items. You assume full responsibility to determineand/or assure compliance with any such standards and related certifications as may be applicable. You will employ reasonablesafeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail toperform as described or expected.4. You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials.Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per theuser guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, andenvironmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contacta TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of thespecified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/orinterface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to theload specification, please contact a TI field representative. During normal operation, some circuit components may have case temperaturesgreater than 60°C as long as the input and output are maintained at a normal ambient operating temperature. These components includebut are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using theEVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, pleasebe aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeablein electronic measurement and diagnostics normally found in development environments should use these EVMs.Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representativesharmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or inconnection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claimsarise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (suchas life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as deviceswhich are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separateAssurance and Indemnity Agreement.Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265Copyright © 2013, Texas Instruments Incorporated