Texas Instruments 2530EM The CC2530EM is a development tool for TIs 2.4 GHz CC2530 IEEE 802.15.4 System-on-Chip. User Manual

Texas Instruments Inc. The CC2530EM is a development tool for TIs 2.4 GHz CC2530 IEEE 802.15.4 System-on-Chip.

User Manual

    SWRA275A     July 2013   CC2530EMK Quick Start Guide   1. Kit Contents    2 x CC2530EM 2 x Pulse W1010 Antennas Documentation  The RF boards in this kit are FCC and IC certified  and  tested  to  comply  with ETSI/R&TTE  standards  over temperature  from  0  to  +35°C.  The antenna,  W1010  from  Pulse,  is  a  ¼ wave dipole antenna with 2 dBi gain.  FCC/IC Regulatory Compliance FCC Part 15 Class A Compliant IC ICES-003 Class A Compliant   2. Plug EM into SmartRF05EB    The  CC2530EM,  with  the  antenna mounted  on  the  SMA  connector,  can  be plugged  into  a  SmartRF05EB.  The SmartRF05EB is included in the CC2530 Development Kit [2].  Caution! The  kit contains ESD sensitive components. Handle with care to prevent permanent damage. 3. Configure the SmartRF05EB  Set  the  EM  Selection  switch  in  position SOC/TRX.  For  best  performance,  it  is recommended to turn off the RS232 interface.    Select power source with the jumper on header P11:   Position 1-2: Batteries   Position 2-3: USB or DC supply    Warning! To minimize risk of injury or property damage, never use rechargeable batteries to power the board. Always select a power source that is suitably rated for use with this EVM, not exceeding 20 VDC, with a current output rating between 0 and 1500 mA. Note that there should only be one active power source at any one time. Do not leave the EVM powered when unattended. 4. Packet Error Rate (PER)     When  power  is  applied  to  the SmartRF05EB, the preprogrammed PER test on the CC2530 will start running.   The  LCD  will  display  the  screen  as shown in the picture above. The number in the parentheses is the revision of the CC2530.  Press  Button  1  to continue.   5. Select Channel    Select  one  of  the  16  IEEE  802.15.4 channels, with channel number from 11 to 26  (2405-2480  MHz,  5  MHz  channel spacing).  Select  the  same  channel  for both boards.  The  channel  is  selected  by  moving  the joystick to the right or left.   Press Button 1 to confirm the selection.   6 Set up the Receiver    Set one of the boards to operate as receiver. Use  the  joystick  to  select  mode.  Confirm  by pressing Button 1.    The receiver will now wait for packets from the transmitter. 7. Set up the Transmitter    Set  the  other  board  to  operate  as transmitter.  Use  the  joystick  to  select mode. Confirm the selection by pressing Button 1.  On  the  transmitter  node,  additional parameters have to be set. On the next screen,  select  the  TX  output  power (signal  strength).  Use  the  joystick  to select between -3 dBm, 0 dBm or 4 dBm. Confirm the selection with Button 1. 8. TX: Packets and Rate    Next, select burst size (number of packets to send) by using the joystick, either 1000, 10K,  100K  or  1M  packets.  Confirm  the selection with Button 1.   After  selecting  burst  size,  select  packet rate; 100, 50, 20 or 10 packet per second. Confirm the selection with Button 1.   9. TX: Start PER Test    The transmitter is now configured for the PER test.  The PER  test  is  started  and  stopped  by pushing  the  joystick  (as  a  button).  The transmitter will  display the  number  of  packets sent during the PER test.   After  stopping  the  test,  it  will  start  from  the beginning if the test is restarted.  OFF SOC/TRX
    SWRA275A     July 2013   10. RX: Observe PER  The  PER  test  receiver  will  display  the PER  value  (number  of  lost  and erroneous  packets  divided  by  the number of  packets sent, displayed as a fraction of 1000).    The receiver will also display the number of  received  packets  and  a  moving average RSSI value based on the last 32 packets.  By pressing button 1, all counters on the receiver will be reset and the receiver will restart the PER calculations. 11. SmartRF Studio  After  running  the  PER  test,  the  next recommended step  is  to  install  SmartRF Studio  and  to  connect  the  evaluation board to the PC.    When installing SmartRF Studio, you will also  install  the  USB  drivers  required  for the SmartRF05EB board.   SmartRF  Studio  can  be  used  for  RF testing and evaluation of C2530.  SmartRF Studio can be downloaded from www.ti.com/smartrfstudio 12. Flash Programmer  Texas Instruments has a simple tool which can be used to program the flash on the CC2530.     The  Flash  Programmer  application,  available on  the  kit  web  page  [2],  can  be  used  to program  Intel  HEX  files,  read  the  contents  of flash and several other operations.  Programming  of  a  CC2530  can  be  done through the SmartRF05EB.  Production  programming  tools  are  available from TI’s developer network [4].  13. IAR Embedded Workbench  To  develop  software,  program  and debug the CC2530, you should use IAR Embedded Workbench for 8051.    A free evaluation version of IAR EW8051 is included in the kit.  A free, code size limited version can be downloaded from the web. See www.iar.com/ew8051. 14. Packet Sniffer  In  order  to  debug  RF  protocols,  it  is possible  to  use  TI’s  SmartRF  Packet Sniffer.     You can use the CC2531 USB dongle or the  SmartRF05EB  with  a  CC2530EM  to capture the packets.  15. Thank You!  We  hope  you  will  enjoy  working  with  the CC2530  and  associated  Low-Power  RF products from Texas Instruments. A. Available Software  CC2530 Software Examples Source code for the PER test and other simple examples for the CC2530 [1]  RemoTI™ Network Protocol TIs’  implementation  of  the  ZigBee RF4CE standard: www.ti.com/remoti   SimpliciTI™ Network Protocol An  RF  protocol  targeting  simple,  small RF networks:  www.ti.com/simpliciti   TIMAC Software TI’s  IEEE  802.15.4  medium-access-control stack: www.ti.com/timac   Z-Stack™ Software TI’s  ZigBee-compliant  protocol  stack www.ti.com/z-stack B. More information  On  Texas  Instruments’  Low-Power  RF web  site  you  will  find  all  our  latest products,  application  and  design  notes, FAQ  section,  news  and  events  updates, and  much  more.  Just  go  to www.ti.com/lprf   The  Low  Power  RF  Online  Community has  forums,  blogs  and  videos.  Use  the forums  to  find  information,  discuss  and get  help  with  your  design.  Join  us  at www.ti.com/lprf-forum   The TI LPRF eNewsletter keeps you up to date  on  e.g.  new  products,  application notes,  software  and  events.  Sign  up  at www.ti.com/lprfnewsletter     C. References  [1]  CC2530 product web page www.ti.com/product/cc2530  [2]  CC2530 Development Kit www.ti.com/tool/cc2530dk  [3] SmartRF05EB User’s Guide www.ti.com/lit/pdf/swru210   [4] LPRF Developer’s Network http://focus.ti.com/general/docs/gencontent.tsp?contentId=98994
EVALUATIONBOARD/KITIMPORTANTNOTICETexasInstruments(TI)providestheenclosedproduct(s)underthefollowingconditions:Thisevaluationboard/kitisintendedforuseforENGINEERINGDEVELOPMENT,DEMONSTRATION,OREVALUATIONPURPOSESONLYandisnotconsideredbyTItobeafinishedend-productfitforgeneralconsumeruse.Personshandlingtheproduct(s)musthaveelectronicstrainingandobservegoodengineeringpracticestandards.Assuch,thegoodsbeingprovidedarenotintendedtobecompleteintermsofrequireddesign-,marketing-,and/ormanufacturing-relatedprotectiveconsiderations,includingproductsafetyandenvironmentalmeasurestypicallyfoundinendproductsthatincorporatesuchsemiconductorcomponentsorcircuitboards.Thisevaluationboard/kitdoesnotfallwithinthescopeoftheEuropeanUniondirectivesregardingelectromagneticcompatibility,restrictedsubstances(RoHS),recycling(WEEE),FCC,CEorUL,andthereforemaynotmeetthetechnicalrequirementsofthesedirectivesorotherrelateddirectives.Shouldthisevaluationboard/kitnotmeetthespecificationsindicatedintheUser’sGuide,theboard/kitmaybereturnedwithin30daysfromthedateofdeliveryforafullrefund.THEFOREGOINGWARRANTYISTHEEXCLUSIVEWARRANTYMADEBYSELLERTOBUYERANDISINLIEUOFALLOTHERWARRANTIES,EXPRESSED,IMPLIED,ORSTATUTORY,INCLUDINGANYWARRANTYOFMERCHANTABILITYORFITNESSFORANYPARTICULARPURPOSE.Theuserassumesallresponsibilityandliabilityforproperandsafehandlingofthegoods.Further,theuserindemnifiesTIfromallclaimsarisingfromthehandlingoruseofthegoods.Duetotheopenconstructionoftheproduct,itistheuser’sresponsibilitytotakeanyandallappropriateprecautionswithregardtoelectrostaticdischarge.EXCEPTTOTHEEXTENTOFTHEINDEMNITYSETFORTHABOVE,NEITHERPARTYSHALLBELIABLETOTHEOTHERFORANYINDIRECT,SPECIAL,INCIDENTAL,ORCONSEQUENTIALDAMAGES.TIcurrentlydealswithavarietyofcustomersforproducts,andthereforeourarrangementwiththeuserisnotexclusive.TIassumesnoliabilityforapplicationsassistance,customerproductdesign,softwareperformance,orinfringementofpatentsorservicesdescribedherein.PleasereadtheUser’sGuideand,specifically,theWarningsandRestrictionsnoticeintheUser’sGuidepriortohandlingtheproduct.Thisnoticecontainsimportantsafetyinformationabouttemperaturesandvoltages.ForadditionalinformationonTI’senvironmentaland/orsafetyprograms,pleasecontacttheTIapplicationengineerorvisitwww.ti.com/esh .NolicenseisgrantedunderanypatentrightorotherintellectualpropertyrightofTIcoveringorrelatingtoanymachine,process,orcombinationinwhichsuchTIproductsorservicesmightbeorareused.FCCWarningThisevaluationboard/kitisintendedforuseforENGINEERINGDEVELOPMENT,DEMONSTRATION,OREVALUATIONPURPOSESONLYandisnotconsideredbyTItobeafinishedend-productfitforgeneralconsumeruse.Itgenerates,uses,andcanradiateradiofrequencyenergyandhasnotbeentestedforcompliancewiththelimitsofcomputingdevicespursuanttopart15ofFCCrules,whicharedesignedtoprovidereasonableprotectionagainstradiofrequencyinterference.Operationofthisequipmentinotherenvironmentsmaycauseinterferencewithradiocommunications,inwhichcasetheuserathisownexpensewillberequiredtotakewhatevermeasuresmayberequiredtocorrectthisinterference.EVMWARNINGSANDRESTRICTIONSItisimportanttooperatethisEVMwithintheinputvoltagerangeof5V.Exceedingthespecifiedinputrangemaycauseunexpectedoperationand/orirreversibledamagetotheEVM.Iftherearequestionsconcerningtheinputrange,pleasecontactaTIfieldrepresentativepriortoconnectingtheinputpower.Applyingloadsoutsideofthespecifiedoutputrangemayresultinunintendedoperationand/orpossiblepermanentdamagetotheEVM.PleaseconsulttheEVMUser'sGuidepriortoconnectinganyloadtotheEVMoutput.Ifthereisuncertaintyastotheloadspecification,pleasecontactaTIfieldrepresentative.Duringnormaloperation,somecircuitcomponentsmayhavecasetemperaturesgreaterthan40°C.TheEVMisdesignedtooperateproperlywithcertaincomponentsabove40°Caslongastheinputandoutputrangesaremaintained.Thesecomponentsincludebutarenotlimitedtolinearregulators,switchingtransistors,passtransistors,andcurrentsenseresistors.ThesetypesofdevicescanbeidentifiedusingtheEVMschematiclocatedintheEVMUser'sGuide.Whenplacingmeasurementprobesnearthesedevicesduringoperation,pleasebeawarethatthesedevicesmaybeverywarmtothetouch.MailingAddress:TexasInstruments,PostOfficeBox655303,Dallas,Texas75265Copyright2007,TexasInstrumentsIncorporated
EVALUATION BOARD/KIT/MODULE (EVM) ADDITIONAL TERMS  Texas Instruments (TI) provides the enclosed Evaluation Board/Kit/Module (EVM) under the following conditions:  The user assumes all responsibility and liability for proper and safe handling of the goods. Further, the user indemnifies TI from all claims arising from the handling or use of the goods.  Should this evaluation board/kit not meet the specifications indicated in the User’s Guide, the board/ kit may be returned within 30 days from the date of delivery for a full refund. THE FOREGOING LIMITED WARRANTY IS THE EXCLUSIVE WARRANTY MADE BY SELLER TO BUYER AND IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED, IMPLIED, OR STATUTORY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. EXCEPT TO THE EXTENT OF THE INDEMNITY SET FORTH ABOVE, NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES.  Please read the User's Guide and, specifically, the Warnings and Restrictions notice in the User's Guide prior to handling the product. This notice contains important safety information about temperatures and voltages. For additional information on TI's environmental and/or safety programs, please visit www.ti.com/esh or contact TI.  No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine, process, or combination in which such TI products or services might be or are used. TI currently deals with a variety of customers for products, and therefore our arrangement with the user is not exclusive. TI assumes no liability for applications assistance, customer product design, software performance, or infringement of patents or services described herein.   Mailing Address: Texas Instruments Post Office Box 655303 Dallas, Texas 75265  Copyright 2011, Texas Instruments Incorporated    REGULATORY COMPLIANCE INFORMATION   As noted in the EVM User’s Guide and/or EVM itself, this EVM and/or accompanying hardware may or may not be subject to the Federal Communications Commission (FCC) and Industry Canada (IC) rules.  For EVMs not subject to the above rules, this evaluation board/kit/module is intended for use for ENGINEERING DEVELOPMENT, DEMONSTRATION OR EVALUATION PURPOSES ONLY and is not considered by TI to be a finished end product fit for general consumer use. It generates, uses, and can radiate radio frequency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES-003 rules, which are designed to provide reasonable protection against radio frequency interference. Operation of the equipment may cause interference with radio communications, in which case the user at his own expense will be required to take whatever measures may be required to correct this interference.  General Statement for EVMs including a radio  User Power/Frequency Use Obligations: This radio is intended for development/professional use only in legally allocated frequency and power limits.  Any use of radio frequencies and/or power availability of this EVM and its development application(s) must comply with local laws governing radio spectrum allocation and power limits for this evaluation module.  It is the user’s sole responsibility to only operate this radio in legally acceptable frequency space and within legally mandated power limitations.  Any exceptions to this is strictly prohibited and unauthorized by Texas Instruments unless user has obtained appropriate experimental/development licenses from local regulatory authorities, which is responsibility of user including its acceptable authorization.
  For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant  Caution  This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.   FCC Interference Statement for Class A EVM devices  This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.   FCC Interference Statement for Class B EVM devices   This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:    Reorient or relocate the receiving antenna.   Increase the separation between the equipment and receiver.   Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.   Consult the dealer or an experienced radio/TV technician for help.
   For EVMs annotated as IC – INDUSTRY CANADA Compliant   This Class A or B digital apparatus complies with Canadian ICES-003.  Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Concerning EVMs including radio transmitters  This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.  Concerning EVMs including detachable antennas  Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.  This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.  ~  Cet appareil numérique de la classe A ou B est conforme à la norme NMB-003 du Canada.   Les changements ou les modifications pas expressément approuvés par la partie responsable de la conformité ont pu vider l’autorité de l'utilisateur pour actionner l'équipement.  Concernant les EVMs avec appareils radio  Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes : (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.  Concernant les EVMs avec antennes détachables  Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.  Le présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de l'émetteur.
    【Important Notice for Users of this Product in Japan】  This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan!  If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:     (1) Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of Japan,     (2) Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this product, or    (3) Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product.  Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.    Texas Instruments Japan Limited   (address) 24-1, Nishi-Shinjuku 6 chome, Shinjukku-ku, Tokyo, Japan  http://www.tij.co.jp  【ご使用にあたっての注意】  本開発キットは技術基準適合証明を受けておりません。  本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。   (1)電波法施行規則第6条第1項第1号に基づく平成18年3月28日総務省告示第173号で定められた電波暗室等の試験設備でご使用いただく。   (2)実験局の免許を取得後ご使用いただく。   (3)技術基準適合証明を取得後ご使用いただく。  なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。       上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。  日本テキサス・インスツルメンツ株式会社 東京都新宿区西新宿6丁目24番1号 西新宿三井ビル http://www.tij.co.jp
   EVALUATION BOARD/KIT/MODULE (EVM) WARNINGS, RESTRICTIONS AND DISCLAIMERS  For Feasibility Evaluation Only, in Laboratory/Development Environments. Unless otherwise indicated, this EVM is not a finished electrical equipment and not intended for consumer use. It is intended solely for use for preliminary feasibility evaluation in laboratory/development environments by technically qualified electronics experts who are familiar with the dangers and application risks associated with handling electrical mechanical components, systems and subsystems. It should not be used as all or part of a finished end product.  Your Sole Responsibility and Risk. You acknowledge, represent and agree that:  1.  You have unique knowledge concerning Federal, State and local regulatory requirements (including but not limited to Food and Drug Administration regulations, if applicable) which relate to your products and which relate to your use (and/or that of your employees, affiliates, contractors or designees) of the EVM for evaluation, testing and other purposes.  2.  You have full and exclusive responsibility to assure the safety and compliance of your products with all such laws and other applicable regulatory requirements, and also to assure the safety of any activities to be conducted by you and/or your employees, affiliates, contractors or designees, using the EVM. Further, you are responsible to assure that any interfaces (electronic and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electrical shock hazard.  3.  You will employ reasonable safeguards to ensure that your use of the EVM will not result in any property damage, injury or death, even if the EVM should fail to perform as described or expected.  4.  You will take care of proper disposal and recycling of the EVM’s electronic components and packing materials  Certain Instructions. It is important to operate this EVM within TI’s recommended specifications and environmental considerations per the user guidelines. Exceeding the specified EVM ratings (including but not limited to input and output voltage, current, power, and environmental ranges) may cause property damage, personal injury or death. If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads. Any loads applied outside of the specified output range may result in unintended and/or inaccurate operation and/or possible permanent damage to the EVM and/or interface electronics. Please consult the EVM User's Guide prior to connecting any load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative. During normal operation, some circuit components may have case temperatures greater than 60 C as long as the input and output are maintained at a normal ambient operating temperature. These components include but are not limited to linear regulators, switching transistors, pass transistors, and current sense resistors which can be identified using the EVM schematic located in the EVM User's Guide. When placing measurement probes near these devices during normal operation, please be aware that these devices may be very warm to the touch. As with all electronic evaluation tools, only qualified personnel knowledgeable in electronic measurement and diagnostics normally found in development environments should use these EVMs  Agreement to Defend, Indemnify and Hold Harmless. You agree to defend, indemnify and hold TI, its licensors and their representatives harmless from and against any and all claims, damages, losses, expenses, costs and liabilities (collectively, "Claims") arising out of or in connection with any use of the EVM that is not in accordance with the terms of the agreement. This obligation shall apply whether Claims arise under law of tort or contract or any other legal theory, and even if the EVM fails to perform as described or expected.   Safety-Critical or Life-Critical Applications. If you intend to evaluate the components for possible use in safety critical applications (such as life support) where a failure of the TI product would reasonably be expected to cause severe personal injury or death, such as devices which are classified as FDA Class III or similar classification, then you must specifically notify TI of such intent and enter into a separate Assurance and Indemnity Agreement.
IMPORTANTNOTICETexasInstrumentsIncorporatedanditssubsidiaries(TI)reservetherighttomakecorrections,modifications,enhancements,improvements,andotherchangestoitsproductsandservicesatanytimeandtodiscontinueanyproductorservicewithoutnotice.Customersshouldobtainthelatestrelevantinformationbeforeplacingordersandshouldverifythatsuchinformationiscurrentandcomplete.AllproductsaresoldsubjecttoTI’stermsandconditionsofsalesuppliedatthetimeoforderacknowledgment.TIwarrantsperformanceofitshardwareproductstothespecificationsapplicableatthetimeofsaleinaccordancewithTI’sstandardwarranty.TestingandotherqualitycontroltechniquesareusedtotheextentTIdeemsnecessarytosupportthiswarranty.Exceptwheremandatedbygovernmentrequirements,testingofallparametersofeachproductisnotnecessarilyperformed.TIassumesnoliabilityforapplicationsassistanceorcustomerproductdesign.CustomersareresponsiblefortheirproductsandapplicationsusingTIcomponents.Tominimizetherisksassociatedwithcustomerproductsandapplications,customersshouldprovideadequatedesignandoperatingsafeguards.TIdoesnotwarrantorrepresentthatanylicense,eitherexpressorimplied,isgrantedunderanyTIpatentright,copyright,maskworkright,orotherTIintellectualpropertyrightrelatingtoanycombination,machine,orprocessinwhichTIproductsorservicesareused.InformationpublishedbyTIregardingthird-partyproductsorservicesdoesnotconstitutealicensefromTItousesuchproductsorservicesorawarrantyorendorsementthereof.Useofsuchinformationmayrequirealicensefromathirdpartyunderthepatentsorotherintellectualpropertyofthethirdparty,oralicensefromTIunderthepatentsorotherintellectualpropertyofTI.ReproductionofTIinformationinTIdatabooksordatasheetsispermissibleonlyifreproductioniswithoutalterationandisaccompaniedbyallassociatedwarranties,conditions,limitations,andnotices.Reproductionofthisinformationwithalterationisanunfairanddeceptivebusinesspractice.TIisnotresponsibleorliableforsuchaltereddocumentation.Informationofthirdpartiesmaybesubjecttoadditionalrestrictions.ResaleofTIproductsorserviceswithstatementsdifferentfromorbeyondtheparametersstatedbyTIforthatproductorservicevoidsallexpressandanyimpliedwarrantiesfortheassociatedTIproductorserviceandisanunfairanddeceptivebusinesspractice.TIisnotresponsibleorliableforanysuchstatements.TIproductsarenotauthorizedforuseinsafety-criticalapplications(suchaslifesupport)whereafailureoftheTIproductwouldreasonablybeexpectedtocauseseverepersonalinjuryordeath,unlessofficersofthepartieshaveexecutedanagreementspecificallygoverningsuchuse.Buyersrepresentthattheyhaveallnecessaryexpertiseinthesafetyandregulatoryramificationsoftheirapplications,andacknowledgeandagreethattheyaresolelyresponsibleforalllegal,regulatoryandsafety-relatedrequirementsconcerningtheirproductsandanyuseofTIproductsinsuchsafety-criticalapplications,notwithstandinganyapplications-relatedinformationorsupportthatmaybeprovidedbyTI.Further,BuyersmustfullyindemnifyTIanditsrepresentativesagainstanydamagesarisingoutoftheuseofTIproductsinsuchsafety-criticalapplications.TIproductsareneitherdesignednorintendedforuseinmilitary/aerospaceapplicationsorenvironmentsunlesstheTIproductsarespecificallydesignatedbyTIasmilitary-gradeor"enhancedplastic."OnlyproductsdesignatedbyTIasmilitary-grademeetmilitaryspecifications.BuyersacknowledgeandagreethatanysuchuseofTIproductswhichTIhasnotdesignatedasmilitary-gradeissolelyattheBuyer'srisk,andthattheyaresolelyresponsibleforcompliancewithalllegalandregulatoryrequirementsinconnectionwithsuchuse.TIproductsareneitherdesignednorintendedforuseinautomotiveapplicationsorenvironmentsunlessthespecificTIproductsaredesignatedbyTIascompliantwithISO/TS16949requirements.Buyersacknowledgeandagreethat,iftheyuseanynon-designatedproductsinautomotiveapplications,TIwillnotberesponsibleforanyfailuretomeetsuchrequirements.FollowingareURLswhereyoucanobtaininformationonotherTexasInstrumentsproductsandapplicationsolutions:ProductsApplicationsAmplifiersamplifier.ti.comAudiowww.ti.com/audioDataConvertersdataconverter.ti.com Automotivewww.ti.com/automotiveDSPdsp.ti.com Broadbandwww.ti.com/broadbandClocksandTimerswww.ti.com/clocks DigitalControlwww.ti.com/digitalcontrolInterfaceinterface.ti.com Medicalwww.ti.com/medicalLogiclogic.ti.com Militarywww.ti.com/militaryPowerMgmtpower.ti.com OpticalNetworkingwww.ti.com/opticalnetworkMicrocontrollersmicrocontroller.ti.com Securitywww.ti.com/securityRFIDwww.ti-rfid.com Telephonywww.ti.com/telephonyRF/IFandZigBee®Solutionswww.ti.com/lprf Video&Imagingwww.ti.com/videoWirelesswww.ti.com/wirelessMailingAddress:TexasInstruments,PostOfficeBox655303,Dallas,Texas75265Copyright©2008,TexasInstrumentsIncorporated