Texas Instruments Ti 34 Multiview Scientific Calculator Users Manual

2014-12-11

: Texas-Instruments Texas-Instruments-Ti-34-Multiview-Scientific-Calculator-Users-Manual-121580 texas-instruments-ti-34-multiview-scientific-calculator-users-manual-121580 texas-instruments pdf

Open the PDF directly: View PDF PDF.
Page Count: 45

DownloadTexas-Instruments Texas-Instruments-Ti-34-Multiview-Scientific-Calculator-Users-Manual-  Texas-instruments-ti-34-multiview-scientific-calculator-users-manual
Open PDF In BrowserView PDF
TI-34 MultiView™
Scientific Calculator
Important information ............................................................2
Examples ..............................................................................3
Switching the TI-34 MultiView calculator on and off .............3
Display contrast ....................................................................3
Home screen ........................................................................3
2nd functions ........................................................................4
Modes ...................................................................................5
Menus ...................................................................................7
Scrolling ..............................................................................10
Answer toggle .....................................................................11
Last answer ........................................................................11
Order of operations .............................................................12
Clearing and correcting .......................................................14
Math operations ..................................................................14
Integer divide ......................................................................16
Fractions .............................................................................17
Percentages ........................................................................19
x10n key ..............................................................................20
Powers, radicals, and reciprocals .......................................21
Pi .........................................................................................22
Angle menu .........................................................................23
Trigonometry .......................................................................25
Logarithms and exponential functions ................................27
Stored operations (op) ........................................................28
Memory and stored variables .............................................30
Data editor and list conversions ..........................................32
Statistics .............................................................................34
Copyright © 2007 Texas Instruments Incorporated

1

Probability ...........................................................................39
Errors ..................................................................................41
Battery information ..............................................................43
In case of difficulty ..............................................................44
Texas Instruments Support and Service .............................45

Important information
Texas Instruments makes no warranty, either express or
implied, including but not limited to any implied warranties of
merchantability and fitness for a particular purpose, regarding
any programs or book materials and makes such materials
available solely on an "as-is" basis. In no event shall Texas
Instruments be liable to anyone for special, collateral,
incidental, or consequential damages in connection with or
arising out of the purchase or use of these materials, and the
sole and exclusive liability of Texas Instruments, regardless of
the form of action, shall not exceed the purchase price of this
product. Moreover, Texas Instruments shall not be liable for
any claim of any kind whatsoever against the use of these
materials by any other party.
MathPrint, APD, Automatic Power Down, EOS, and MultiView
are trademarks of Texas Instruments Incorporated.

2

Examples
Each section is followed by instructions for keystroke
examples that demonstrate the TI-34 MultiView™ functions.
Examples assume all default settings, as shown in the Modes
section.
For more activities and examples, see the TI-34 MultiView
Teacher Guide available at education.ti.com/guides.

Switching the TI-34 MultiView calculator on
and off
& turns on the TI-34 MultiView calculator. %' turns it
off. The display is cleared, but the history, settings, and
memory are retained.
The APD™ (Automatic Power Down™) feature turns off the
TI-34 MultiView calculator automatically if no key is pressed
for about 5 minutes. Press & after APD. The display,
pending operations, settings, and memory are retained.

Display contrast
The brightness and contrast of the display can depend on
room lighting, battery freshness, and viewing angle.
To adjust the contrast:
1. Press and release the % key.
2. Press T (to darken the screen) or U (to lighten the
screen).

Home screen
On the Home screen, you can enter mathematical
expressions and functions, along with other instructions. The
answers are displayed on the Home screen. The TI-34
MultiView screen can display a maximum of four lines with a
maximum of 16 characters per line. For entries and
expressions of more than 16 characters, you can scroll left
and right (! and ") to view the entire entry or expression.
3

In the MathPrint™ mode, you can enter up to four levels of
consecutive nested functions and expressions, which include
fractions, square roots, exponents with ^, xÑ, and x2.
When you calculate an entry on the Home screen, depending
upon space, the answer is displayed either directly to the right
of the entry or on the right side of the next line.
Special indicators may display on the screen to provide
additional information concerning functions or results.

Indicator Definition
2ND

2nd function.

FIX

Fixed-decimal setting. (See Mode section.)

SCI

Scientific notation. (See Mode section.)

DEG, RAD Angle mode (degrees or radians). (See Mode
section.)
L1, L2, L3 Displays above the lists in Data Editor.
The TI-34 MultiView™ calculator is performing
an operation.
º»

An entry is stored in memory before and/or after
the active screen. Press # and $ to scroll.

¸¹

An entry or menu displays beyond 16 digits.
Press ! and " to scroll. (See Scrolling on
page 10 for more information.)

2nd functions
%
Most keys can perform two functions. The primary function is
indicated on the key and the secondary function is displayed
above it. Press % to activate the secondary function of a
given key. Notice that 2nd appears as an indicator on the
screen. To cancel it before entering data, press % again.
For example, 3 %c 125 < calculates the cube root of
125 and returns the result, 5.

4

Modes
q
Use q to choose modes. Press $ # ! " to choose a
mode, and < to select it. Press - or %s to
return to the Home screen and perform your work using the
chosen mode settings.
Default settings are shown.

DEG RAD Sets the angle mode to degrees or radians.
NORM SCI Sets the numeric notation mode. Numeric
notation modes affect only the display of results, and not the
accuracy of the values stored in the unit, which remain
maximal.
NORM displays results with digits to the left and right of the
decimal, as in 123456.78.
SCI expresses numbers with one digit to the left of the
decimal and the appropriate power of 10, as in
1.2345678x105 (which is the same as 123456.78).
Note: C is a shortcut key to enter a number in scientific
notation format. The result displays in the numeric notation
format set in mode.
Note: In some restricted environments (for example, data
editor and the %h menu), the TI-34 MultiView™
calculator may display E instead of x10n.
FLOAT 0123456789 Sets the decimal notation mode.
FLOAT (floating decimal point) displays up to 10 digits,
plus the sign and decimal.
0123456789 (fixed decimal point) specifies the number of
digits (0 through 9) to display to the right of the decimal.
CLASSIC MATHPRINT
CLASSIC mode displays inputs and outputs in a single
line.

5

MATHPRINT mode displays most inputs and outputs in
textbook format. Choose the MathPrint™ mode for better
visual confirmation that math expressions have been
entered correctly and to better reinforce the correct math
notation.
Note: Switching the mode between Classic and MathPrint
clears calculator history and the stored operations (op1 or
op2) value.
Un/d n/d Determines how fractional results are displayed.
Un/d displays results as a mixed number, if applicable. n/d
displays results as a simple fraction.
MANSIMP AUTOSIMP Determine whether or not a
fractional result will be simplified automatically.
MANSIMP The user simplifies fractions manually step-bystep. » next to the resulting fraction signifies that the
fraction is not yet in simplest form. See Fractions, }
for details.
AUTOSIMP The calculator automatically simplifies
fractional results to the lowest terms.

Example of Classic and MathPrint modes
Classic mode

MathPrint mode

Sci

Sci

Float mode and answer
toggle key.

Float mode and answer toggle
key.

Fix 2

Fix 2 and answer toggle key.

6

n/d U n/d

Mansimp

Autosimp

Exponent example

Exponent example

Cube root example

Cube root example

Menus
Certain keys display menus: H, %=, %A,
,
%B, d, vv, %t, %
%h, and %{.
Press $and " to scroll and select a menu item, or press the
corresponding number next to the menu item. To return to the
previous screen without selecting the item, press -. To
exit a menu or application and return to the Home screen,
press %s.
The menu chart shows the menu keys and the menus they
display.
7

H
PRB
1: nPr
2: nCr
3: !

LOG
1: log(
2: 10^(

MATH
1: lcm(
2: gcd(
3: 3
4: 3Ñ(

RAND
1: rand
2: randint(

%A
LN
1: ln(
2: e^(

%=
DMS
R ¶P
1: Ä
1: R ´Pr(
2: Å
2: R ´PÁ(
3: Æ
3: P ´Rx(
4: r
4: P ´Ry(
5: ´DMS
%B
TRIG
1: sin(
2: cos(
3: tan(
4: sin-1(
5: cos-1(
6: tan-1(

d
NUM
1: abs(
2: round(
3: iPart(
4: fPart(
5: min(
6: max(
7: remainder(

8

vv
(Press once to display the Data editor screen. Press again to
display the menu.)
CLEAR
CNVRSN
1: Clear L1
1: Add/Edit Cnvrs
2: Clear L2
2: Clear L1 Cnvrs
3: Clear L3
3: Clear L2 Cnvrs
4: Clear ALL
4: Clear L3 Cnvrs
5: Clear ALL
Press v while you are in the Add/Edit Conversion option
of the CNVRSN menu to display this menu:
Ls
1: L1
2: L2
3: L3
%t
STATS
1: 1-Var Stats
2: 2-Var Stats
3: StatVars
This menu option displays after you
calculate 1-var or 2-var stats.
StatVars menu:
1: n
2: Ï
3: Sx
Etc. See StatVar values on page 34 for a
full list.

9

%
Reset
1: No
2: Yes

%h
Recall Var
1: x =
2: y =
3: z =
4: t =
5: a =
6: b =
7: c =

%{
Clear Var
1: Yes
2: No

Scrolling
!"#$
Press ! or " to scroll entries on the Home screen and to
navigate in menus. Press %! or %" to move the
cursor directly to the beginning or end of the current
expression.
# and $ moves the cursor up and down through menu
items, entries in Data editor, and previous entries on the
Home screen. You can reuse a previous entry by pressing
< to paste it on the bottom line, and then evaluating a new
expression.
%# moves the cursor to the top entry of the active column
in Data editor, or to the previous entry on the Home screen.
Press %# again to move the cursor to the oldest entry on
the Home screen.
%$ moves the cursor to the first blank row of the active
column in Data editor, or below the last entry on the Home
screen.

Examples
Scroll

1T1<

2T2<

10

3T3<

4T4<

####<

T2<

Answer toggle
r
Press the r key to toggle the display result between fraction
and decimal answers, and exact pi and decimal.

Example
Answer
toggle

2g<

r

Last answer
%i
The most recently calculated result is stored to the variable
ans. ans is retained in memory, even after the TI-34
MultiView™ calculator is turned off. To recall the value of ans:
• Press %i (ans displays on the screen), or
• Press any operations key ( T, U, and so forth) as the first
part of an entry. ans and the operator are both displayed.
11

Examples
ans

3V3<

V3<

3 %c %i
<

Order of operations
The TI-34 MultiView™ calculator uses Equation Operating
System (EOS™) to evaluate expressions. Within a priority
level, EOS evaluates functions from left to right and in the
following order.
1st

Expressions inside parentheses.

2nd

Functions that need a ) and precede the argument,
such as sin, log, and all R ¶P menu items.

3rd

Fractions.

4th

Functions that are entered after the argument,
such as x2 and angle unit modifiers.

12

5th

Exponentiation (^) and roots (xÑ).
Note: In Classic mode, exponentiation using G is
evaluated from left to right. The expression 2^3^2
is evaluated as (2^3)^2, with a result of 64.

In MathPrint™ mode, exponentiation using G is
evaluated from right to left. The expression 2^3^2
is evaluated as 2^(3^2), with a result of 512.

The TI-34 MultiView™ calculator evaluates
expressions entered with F from left to right in
both Classic and MathPrint modes.
6th

Negation (M).

7th

Permutations (nPr) and combinations (nCr).

8th

Multiplication, implied multiplication, division.

9th

Addition and subtraction.

10th

Conversions (n/d ¶U n/d, f¶d, ´DMS).

11th

< completes all operations and closes all open
parentheses.

Examples
+QPM

60 T 5 V M 12 <

(M)

1 T M 8 T 12 <

()

b 9 T 16 <

13

4VD2T3E<

4D2T3E<

^ and xÑ

b3 G2 "T4 G2
<

Clearing and correcting
-

Clears characters and error messages.
Clears characters on the entry line, then
clears the display when you press again. Scroll up to clear entries in history.
Backs up one screen in applications.

J

Deletes the character at the cursor.

%f

Inserts a character at the cursor.

%{
%

2

Clears variables x, y, z, t, a, b and c.
Resets the TI-34 MultiView™ calculator.
Returns unit to default settings; clears
memory variables, pending operations,
all entries in history, functions in
applications, and statistical data; clears
stored operations (op1 or op2), and ans.

Math operations
d
d displays a menu with two submenus. Some functions
require you to enter 2 values, numbers, or expressions that
equal or return a number. %` separates two values.

14

MATH submenu:
lcm(n1, n2)
gcd(n1, n2)

Finds the least common multiple (lcm) or
greatest common divisor (gcd) of two
values, n1 and n2, which are positive
integers.

n3

Calculates the cube of n.

3

Calculates the cube root of n.

Ñ(n

NUM submenu:
abs(n)

Displays absolute value of n.

round(n,digits)

Rounds n to specified number of digits.

iPart(n)
fPart(n)

Returns only the integer part (iPart) or
fractional (decimal) part (fPart) of n.

min(n1, n2)
max(n1, n2)

Returns the minimum (min) or maximum
(max) of two values, n1 and n2.

remainder(n1, n2) Returns the remainder resulting from the
division of 2 values, n1 by n2.

Examples
abs

d"1M2P3
<

round

d " 2 g %` 3
E<

iPart, fPart

d"3
23 8 45 E <
d"4
23 8 45 E <

3

2d3<

Ñn, n3

15

d4
8<
remainder

d"7
10 %` 6 E <

³ Problem
Find the least common multiple of 30 and 84 using prime
factorization by hand. Verify your work using the calculator.
2V3V5<
2FV3V7<
2FV3V5V7<
d1
30 %` 84 E <
The lcm (30, 84) is 420.

Integer divide
%Y
%Y divides 2 positive integers and displays the
quotient, q, and the remainder, r. Only the quotient is stored to
ans.

Example
Int divide

17 %Y 3 <

³ Problem
How many hours, minutes, and seconds are there in 17589
seconds?
17589 %Y 60 <

16

%i %Y 60 <

17589 seconds equals 4 hours, 53 minutes, and 9 seconds.

Fractions
P
@
%O
}
%j
In the MathPrint™ mode, fractions with P can include
operation keys (T, V, etc.) and most function keys (F, _,
etc.).
In Classic mode, fractions with P do not allow operation
keys, functions, or complex fractions in the numerator or
denominator.
Note: In Classic mode and Data editor, use W to perform
complex division problems.
Calculations using fractions can display fraction or decimal
results, depending on input.
• P enters a simple fraction. Pressing P before or after a
number can result in different behavior. Entering a number
before pressing P makes that number the numerator.
To enter fractions with operators, press P before you
enter a number (in MathPrint mode only).
In MathPrint mode, press $ between the entry of the
numerator and the denominator.
In Classic mode, press P between the entry of the
numerator and the denominator.
• @ enters a mixed number. Press @ between the entry
of the unit and the numerator, and press $ between the
entry of the numerator and the denominator.
• } n < simplifies a fraction by the factor n specified
The entry n must be a positive integer.
• } < automatically simplifies a fraction using the
lowest common prime factor. The factor displays.
Repeatedly press } < to simplify the fraction to its
lowest terms.
17

• %O converts between simplie fraction and mixed
number form.
• %j converts results between fractions and
decimals.
From q, you can select
• ManSimp (default) The user simplifies fractions manually
step-by-step. » next to the resulting fraction signifies that
the fraction is not yet in simplest form.
• AutoSimp The calculator automatically simplifies
fractional results to the lowest terms.

Examples of Classic mode
n/d, U n/d

3 P 4 T 1 @ 7 P12
<

Simp

}2<

}2<

n/d ¶U n/d

9 P 2 %O <

f ¶d

4 @1 P 2 %j
<

Examples of MathPrint™ mode
n/d, U n/d

P3$4"T1@7
$ 12 <

Simp

}2<

18

}2<

n/d ¶U n/d

9 P 2 " %O
<

f ¶d

4@1$2"
%j <

Examples
P182T183$4
(MathPrint™ " <
mode only)
(MathPrint
mode only)

PM5Tb5F
U4D1ED6E
$2D1E"<

Percentages
_
%N
To perform a calculation involving a percentage, enter a
number and press _to append the % sign.
To express a value as a percentage, press %N after the
value.

Example
2 _V 150 <

1 P 5 " %N <

19

³ Problem
A mining company extracts 5000 tons of ore with a
concentration of metal of 3%, and 7300 tons with a
concentration of 2.3%. On the basis of these two extraction
figures, what is the total quantity of metal obtained?
If one ton of metal is worth $280, what is the total value of the
metal extracted?
3 _V 5000 <

T 2 8 3 _V 7300 <

V 280 <

The two extractions represent a total of 317.9 tons of metal for
a total value of $89,012.

x10n key
C
C is a shortcut key to enter a number in scientific notation
format.

Example
2C5<

q$"<

-<

20

Powers, radicals, and reciprocals
F

Calculates the square of a value. The TI-34
MultiView™ calculator evaluates expressions
entered with F from left to right in both Classic
and MathPrint™ modes. Pressing 3 F F
calculates as (32)2 = 81.

G

Raises a value to the power indicated. If you
insert an expression as the exponent, you must
place it between parentheses.
In Classic mode, exponentiation using G is
evaluated from left to right. The expression
2^3^2 is evaluated as (2^3)^2, with a result of 64.
In MathPrint™ mode, exponentiation using G is
evaluated from right to left. The expression
2^3^2 is evaluated as 2^(3^2), with the result
of 512.

b

Calculates the square root of a positive value.

%c

Calculates the xth root of any positive value and
any odd integer root of a negative value.

%a

Calculates the reciprocal of a value.

Examples
5FT4GD2T1E<

10 G M 2 <

b 49 <

b3FT2G4 <

21

6 %c 64 <

D 2 T 6 E %a <

Pi
g
À ≈ 3.141592653590 for calculations.
À ≈ 3.141592654 for display.

Example
À

2Vg<

r

Note: Classic mode displays calculations with À as a decimal
approximation.

³ Problem
What is the area of a circle if the radius is 12 cm?
Reminder: A = Àr2.
g V 12 G 2 <

r

The area of the circle is 144 À square cm. The area of the
circle is approximately 452.4 square cm when rounded to one
decimal place.
22

Angle menu
%=
%= displays the choice of two submenus that enable
you to specify the angle unit modifier as degrees (º), minutes
('), seconds ("), radian (r), or convert units using 4DMS. You
can also convert between rectangular coordinate form (R) and
polar coordinate form (P).
Choose an angle mode from the mode screen. You can
choose from DEG (default) or RAD. Entries are interpreted
and results displayed according to the angle mode setting
without needing to enter an angle unit modifier.
If you specify an angle unit modifier from the Angle menu, the
calculation is performed in that angle type, but the result will
be given in the angle mode setting.

Examples
RAD

q"<

- %B 1
30 %= 1 E <
DEG

q<

ÄÅÆ

- 2 g %= 4
<

4DMS

1 8 5 %= 5 <

23

Convert polar coordinates (r, q)=(5, 30) into rectangular
coordinates. Then convert rectangular coordinates
(x, y) = (3, 4) into polar coordinates. Round the results to one
decimal place.
R ¶P

-q$$""
<
- %= " 3
5 %` 30 E <
%= " 4
5 %` 30 E <
%= " 1
3 %` 4 E <
%= " 2
3 %` 4 E <

Converting (r, q) = (5, 30) gives (x, y) = (4.3, 2.5) and
(x, y) = (3, 4) gives (r, q) = (5.0, 53.1).
³ Problem
Two adjacent angles measure 12¡ 31¢ 45£ and 26¡ 54¢ 38£
respectively. Add the two angles and display the result in
DMS format. Round the results to two decimal places.
-q$$"""<

- 12 %=

1
31 %= 2
45 %= 3 T 26 %= 1
54 %= 2
38 %= 3 <
%= 5 <

The result is 39 degrees, 26 minutes and 23 seconds.
24

³ Problem
It is known that 30¡ = À / 6 radians. In the default mode,
degrees, find the sine of 30¡. Then set the calculator to radian
mode and calculate the sine of À / 6 radians.
Note: Press - to clear the screen between problems.
- %B 1
30 E <
q"<%B 1 g P 6 " E <
Retain radian mode on the calculator and calculate the sine of
30¡. Change the calculator to degree mode and find the sine
of À / 6 radians.
%B 1
30 %= < E <
q<%B 1 g P 6 " %= 4
E<

Trigonometry
%B
%B displays a menu of all trigonometric functions (sin,
cos, tan, sin-1, cos-1, tan-1). Select the trigonometric function
from the menu and then enter the value. Set the desired
Angle mode before starting trigonometric calculations.

Example Degree mode
Tan

q<$$<
- %B 3
45E<

25

Tan-1

%B 6
1E<

Cos

5 V %B 2
60 E <

Example Radian mode
Tan

q"<%B 3 g P 4 " E
<

Tan-1

%B 6
1E<
r

Cos

5 V %B 2 g P 4
"E<

³ Problem
Find angle A of the right triangle below. Then calculate angle
B and the length of the hypotenuse c. Lengths are in meters.
Round results to one decimal place.
Reminder:
7
7
tan A = --- therefore m±A = tan-1 ⎛⎝ --- ⎞⎠
3
3
m±A + m±B + 90Ä = 180Ä
therefore m±B = 90Ä - m±A
c=

2

3 +7

2

A
c

3
C

7

B

26

q< $ $ " " < %B 6
7P3"E<
90 U %i <

b3FT7F<

To one decimal place, the measure of angle A is 66.8Ä, the
measure of angle B is 23.2Ä, and the length of the hypotenuse
is 7.6 meters.

Logarithms and exponential functions
%A
%A displays two submenus containing the functions log,
10^, ln, and e^. Select the submenu, the desired log function,
then enter the value and close the expression with E <.
• log yields the common logarithm of a number.
• 10^ raises 10 to the power you specify.
• ln yields the logarithm of a number ot the base of e
(e ≈ 2.718281828459).
• e^ raises e to the power you specify.

Examples
LOG

%A 1
1E<

10^

%A 2 %A 1
2E<
%A 1 %A 2
5"E<

27

LN

%A " 1
5EV2<

e^

%A " 2
85<

Stored operations (op)
m
o
%n
%p
The TI-34 MultiView™ calculator stores two operations, op1
and op2. To store an operation to op1 or op2 and recall it:
1. Press %n or %p. You may have to press
- if a previous operation is displayed.
2. Enter the operation (any combination of numbers,
operations, or menu items and their arguments).
3. Press < to save the operation to memory.
4. m or orecalls and displays the operation on the
entry line. The TI-34 MultiView™ calculator automatically
calculates the result (without pressing <).

Examples
Set op1

%n V 2 T 3
<

op1

4m

6m

Set op2

%p V 10 <

28

op2

1o

o

o

³ Problem
Harry's father will pay him $15 per week if he helps out a few
hours at his family's grocery store. Harry would like to save all
he earns to buy several of his favorite books and video
games. He estimates that he will need to earn $240 to buy
everything he would like to have. Create a table of Harry's
weekly earnings to see how his savings will grow. How many
weeks will Harry need to work to save enough money for his
purchases?
%n
(Press - if necessary to clear a
previous operation.)

T 15 <
0 mmmm

mmmm

mmmm

mmmm

29

The table of values of Harry's weekly earnings is shown on
the screens. From this table, we can read that Harry will have
to work 16 weeks to earn $240.

Memory and stored variables
z
L
%h
%{
The TI-34 MultiView™ calculator has 7 memory variables—x,
y, z, t, a, b, and c. You can store a real number or an
expression that results in a real number to a memory variable.
L lets you store values to variables. Press L to store a
variable, and press z to select the variable to store. Press
< to store the value in the selected variable. If this
variable already has a value, that value is replaced by the
new one.
z acesses the variables. Press this key multiple times to
choose x, y, z, t, a, b, or c. You can also use z to recall the
stored values for these variables. The name of the variable is
inserted into the current entry, but the value assigned to the
variable is used to evaluate the expression.
%h recalls the values of variables. Press %h
to display a menu of variables and their stored values. Select
the variable you want to recall and press <. The value
assigned to the variable is inserted into the current entry and
used to evaluate the expression.
%{ clears all variable values. Press %{
and select 1: Yes to clear all variable values.

Examples
Clear Var

%{ 1

Store

15 L z

<

30

Recall

%h

 1.
• For nCr or nPr: n or r are not integers | 0.
• For }: Entering a simplify value of 0; using a simplify
value of ‚ 1E10; attempting to simplify non-fractions.
EQUATION LENGTH — An entry exceeds the digit limits (88
for entry line and 47 for stat entries or constant entries); for
example, combining an entry with a constant that exceeds the
limit.
FRQ DOMAIN — FRQ value (in 1-var statistics) < 0.
OVERFLOW — You attempted to enter, or you have
calculated, a number that is beyond the range of the
calculator.
STAT — Attempting to calculate 1-var or 2-var stats with no
defined data points, or attempting to calculate 2-var stats
when the data lists are not of equal length.
CONVERSION —
• The conversion does not contain a list name (L1, L2, or L3)
followed by a conversion (for example, f ¶d).
• You attempted to enter a function (for example, L1 + 3).
SYNTAX — The command contains a syntax error, or has
misplaced functions, arguments, parentheses, or commas. If
using P, try using W.

42

OP NOT DEFINED — Operation (op1 or op2) is not defined.
MEMORY LIMIT —
• The calculation contains too many pending operations
(more than 23).
• If using op1 or op2, you attempted to enter more than four
levels of nested functions using fractions, square roots,
exponents with ^, xÑ, and x2 (MathPrint™ mode only).
LOW BATTERY — Replace the battery.
Note: This message displays briefly and then disappears.
Pressing - does not clear this message.

Battery information
Battery precautions
• Do not leave batteries within the reach of children.
• Do not mix new and used batteries. Do not mix brands (or
types within brands) of batteries.
• Do not mix rechargeable and non-rechargeable batteries.
• Install batteries according to polarity (+ and -) diagrams.
• Do not place non-rechargeable batteries in a battery
recharger.
• Properly dispose of used batteries immediately.
• Do not incinerate or dismantle batteries.
• Seek medical advice immediately if a cell or battery has
been swallowed. In the USA, contact the National Capital
Poison Center collect at 1-800-222-1222.

Battery disposal
Do not mutilate, puncture, or dispose of batteries in fire. The
batteries can burst or explode, releasing hazardous
chemicals. Discard used batteries according to local
regulations.
Per CA Regulation 22 CCR 67384.4, the following applies to
the button cell battery in this unit:
Perchlorate Material - Special handling may apply.
See www.dtsc.ca.gov/hazardouswaste/perchlorate
43

How to remove or replace the battery
The TI-34 MultiView™ calculator uses one 3 volt CR2032
lithium battery.
Remove the protective cover and turn the TI-34 MultiView
calculator face downwards.
• With a small screwdriver, remove the screws from the back
of the case.
• From the bottom, carefully separate the front from the
back. Be careful not to damage any of the internal parts.
• With a small screwdriver (if required), remove the battery.
• To replace the battery, check the polarity (+ and -) and
slide in a new battery. Press firmly to snap the new battery
into place.
Important: When replacing the battery, avoid any contact
with the other components of the TI-34 MultiView
calculator.
Dispose of the dead battery immediately and in accordance
with local regulations.

In case of difficulty
Review instructions to be certain calculations were performed
properly.
Check the battery to ensure that it is fresh and properly
installed.
Change the battery when:
• & does not turn the unit on, or
• The screen goes blank, or
• You get unexpected results.

44

Texas Instruments Support and Service
For general information
Home Page:
KnowledgeBase
and e-mail
inquiries:
Phone:

education.ti.com

International
information:

education.ti.com/international

education.ti.com/support

(800) TI-CARES / (800) 842-2737
For U.S., Canada, Mexico, Puerto
Rico, and Virgin Islands only

For technical support
KnowledgeBase
and support by
e-mail:
Phone
(not toll-free):

education.ti.com/support

(972) 917-8324

For product (hardware) service
Customers in the U.S., Canada, Mexico, Puerto Rico and
Virgin Islands: Always contact Texas Instruments Customer
Support before returning a product for service.
All other customers: Refer to the leaflet enclosed with this
product (hardware) or contact your local Texas Instruments
retailer/distributor.

45



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Copy, Extract, Print high-res
Create Date                     : 2006:05:04 09:19:06Z
Creator                         : FrameMaker 7.2
Modify Date                     : 2014:12:07 13:56:44+08:00
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : FrameMaker 7.2
Metadata Date                   : 2014:12:07 13:56:44+08:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:4d09340f-651f-4a8c-ace1-cbbad5c4718f
Instance ID                     : uuid:3f6b1496-2eea-5b43-8fe9-6f17f0dcddd3
Page Layout                     : SinglePage
Page Mode                       : UseNone
Page Count                      : 45
EXIF Metadata provided by EXIF.tools

Navigation menu