The Watt Stopper d b a Qmotion 150017 Zigbee Hardwired Roller User Manual 15 0410 Exhibit Cover
Qmotion Incorporated Zigbee Hardwired Roller 15 0410 Exhibit Cover
Manual
Certification Exhibit FCC ID: 2ABLX-150017 IC: 8832A-150017 FCC Rule Part: 15.247 IC Radio Standards Specification: RSS-247 ACS Project Number: 15-0410 Manufacturer: Qmotion Incorporated Model: QM150017 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598 FCC Warning: Changes or modifications to this device not expressly approved by QMotion ® Incorporated -Advanced Shading Systems could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. RF Exposure This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. QMotion ZigBee Hard Wired Control Roller Shade Application Guide INDUSTRY CANADA This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. RF Exposure Cet équipement est conforme aux limites ďexposition aux radiations dans un environnement noncontrôlé. Cet équipement doit être installé et utilisé à distance minimum de 20cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisées ou opérant en conjunction avec tout autre antenne ou transmetteur. REVISION 1.1 07DEC15 Part # REVISION 1.1 07DEC15 Part # ZigBee Hardwired Roller Shade Third Party Integration ZigBee Hardwired Roller Shade System Overview Power Distribution Panels 24 VDC Power Supplies RS485 Communication Third Party Integration Wire Specification: Category 5e/Category 6 for use with RJ-45 Connector 24 AWG Maximum length of wire from Power Distribution Panel to device : - 8’ X 8’ Shade with 40:1 motor - 1250’ - 12’ X 12’ Shade with 73:1 motor - 750’ - 12’ X 20’ Shade with 73:1 motor - 500’ - Hardwired 4 and 8 Button Switches - 1000’ *Length based on 115K baud rate Maximum wire length for RS485 communication - 2000’ System Capacity: 200 Devices (QMotion Shades, QMotion Wireless Remotes, QMotion Hardwired Switches and other ZigBee devices) Power Distribution Panel: Power Supply: 24 VDC, 7.5A 8 RJ-45 ports for motorized shades and switches 2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels and Third Party Integration via RS485. Power Supply - AC Input: 100-240 VAC, 2.5A RJ-45 Ports for Motorized Shades and Switches - Quantity 8 - DC Output: 24 VDC, 7.5A Communication Ports (RJ-45) - Quantity 2 Note: Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown). Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window . *Specifications are subject to change without notice REVISION 1.1 07DEC15 Part # REVISION 1.1 07DEC15 Part # ZigBee Hardwired Roller Shade Single Hardwired Switch Application ZigBee Hardwired Roller Shade Third Party Integration Power Distribution Panel 24 VDC Power Supplies 24 VDC Power Supply Power Distribution Panels Hardwired Switch Wire Specification: Category 5e/Category 6 for use with RJ-45 Connector 24 AWG Maximum length of wire from Power Distribution Panel to device: - 8’ X 8’ Shade with 40:1 motor - Hardwired Switch 24 VDC Power Supplies 1250’ - 12’ X 12’ Shade with 73:1 motor - 750’ - 12’ X 20’ Shade with 73:1 motor - 500’ - Hardwired 4 and 8 Button Switches - 1000’ *Length based on 115K baud rate RS485 Maximum wire length for RS485 communication - 2000’ Communication System Capacity: Third Party Integration 200 Devices (QMotion Shades, QMotion Hardwired Switches) Power Distribution Panel: ZigBee Remote ZigBee Coordinator/ Router 8 RJ-45 ports for motorized shades and switches 2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels and Third Party Integration via RS485. Power Supply - AC Input: 100-240 VAC, 2.5A Caution - DC Output: 24 VDC, 7.5A NOTE: The QMotion ZigBee Hardwired System does not operate on “standard” Power over Ethernet (PoE) schemes. Do not attempt to connect the QMotion ZigBee Hardwired System to any Ethernet device. Doing so may damage the system components and/or the external Ethernet or PoE device. Note: Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown). Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window . *Specifications are subject to change without notice REVISION 1.1 07DEC15 Part # REVISION 1.1 07DEC15 Part # ZigBee Hardwired Roller Shade Multiple Power Distribution Panel Application Hardwired Switch Wire Specification: Category 5e/Category 6 for use with RJ-45 Connector 24 AWG ZigBee Hardwired Roller Shade Wireless Remote / Optional Hardwired Switch Application Maximum length of wire from Power Distribution Panel to device: - 8’ X 8’ Shade with 40:1 motor 1250’ - 12’ X 12’ Shade with 73:1 motor 750’ - 12’ X 20’ Shade with 73:1 motor 500’ - Hardwired 4 and 8 Button Switches 1000’ *Length based on 115K baud rate Maximum wire length for RS485 communication - 2000’ Power Distribution Panel Power Distribution Panel 24 VDC Power Supply 24 VDC Power Supply RS485 Communication 200 Devices (QMotion Shades, QMotion Hardwired Switches) Power Distribution Panel Category 5e/Category 6 for use with RJ-45 Connector 24 AWG Maximum length of wire from Power Distribution Panel to device: - 8’ X 8’ Shade with 40:1 motor - 1250’ Power Distribution Panel: - 12’ X 12’ Shade with 73:1 motor - 750’ 8 RJ-45 ports for motorized shades and switches - 12’ X 20’ Shade with 73:1 motor - 500’ 2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels and Third Party Integration via RS485. Power Supply - Hardwired 4 and 8 Button Switches - 1000’ ZigBee Remote *Length based on 115K baud rate Maximum wire length for RS485 communication - 2000’ System Capacity: 24 VDC Power Supply - AC Input: 100-240 VAC, 2.5A 200 Devices (QMotion Shades, QMotion Wireless Remotes, QMotion Hardwired Switches and other ZigBee devices) Power Distribution Panel: - DC Output: 24 VDC, 7.5A 8 RJ-45 ports for motorized shades and switches 2 additional RJ-45 communication ports dedicated to daisy chain with other Power Distribution Panels and Third Party Integration via RS485. Power Supply - AC Input: 100-240 VAC, 2.5A Note: Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown). Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window . 07DEC15 - DC Output: 24 VDC, 7.5A Note: Standard Roll Applications (Motor Left) - Wire will need to be run to the LEFT side of the window (as shown). Reverse Roll Applications (Motor Right) - Wire will need to be run to the RIGHT side of the window . *Specifications are subject to change without notice *Specifications are subject to change without notice REVISION 1.1 ZigBee Coordinator/ Router Wire Specification: System Capacity: Hardwired Switch Part # REVISION 1.1 07DEC15 Part #
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Print high-res Page Count : 5 XMP Toolkit : 3.1-701 Producer : ScanSoft PDF Create! 7 Creator Tool : Microsoft Word - 15-0410 - Exhibit Cover.doc Create Date : 2015:12:17 13:48:50-05:00 Modify Date : 2015:12:17 13:49:33-05:00 Title : Microsoft Word - 15-0410 - Exhibit Cover.doc Creator : courtney.mcgann Author : courtney.mcgannEXIF Metadata provided by EXIF.tools