The Watt Stopper EOPC-100 Wireless Self-Powered PIR Ceiling Mount Extented Range Occupancy Sensor User Manual

The Watt Stopper, Inc. Wireless Self-Powered PIR Ceiling Mount Extented Range Occupancy Sensor Users Manual

User Manual

Quick Start Guide
SENSOR PLACEMENT 12’ MAX. HEIGHT
PAIRING OF SENSOR TO RECEIVER LOADS
,WLVUHFRPPHQGHGWKDWSDLULQJRIGHYLFHVEHGRQHSULRUWR
LQVWDOOLQJFHLOLQJVHQVRU
Step 1: Enter Pairing Mode
Press and Hold “Pairing” Button on
Receiver for 3 Seconds then release:
âÝ3DLULQJÞ/('EOLQNVWLPHV
VHFRQGWRFRQILUPSDLULQJPRGH
For EOSW-101
âLoad 1 turns ONDQGLVUHDG\
WREHSDLUHG
â%XWWRQ/('LV6ROLGON
For EOSW-102
â/RDGWXUQON and are
UHDG\WREHSDLUHG
â%XWWRQ/('DUH6ROLGON
Step 2: Selecting a Specific Load to Pair
(EOSW-102)
,IERWKORDGVDUHWREHFRQWUROOHGE\
2FFXSDQF\6HQVRUWKDQVNLSWKLVVWHS
Tap the “Pairing” button once
while in pairing mode:
â/RDGWXUQVOFF and Load 1
UHPDLQVON
â/RDGLVQRZDFWLYHDQG
UHDG\WREHSDLUHGWRVHOHFWHG
WUDQVPLWWHUV
â/RDG/('LV6ROLGON
Tap the “Pairing” button once
again while in pairing mode:
â/RDGWXUQVOFF and Load 2
turns ON
â/RDGLVQRZDFWLYHDQG
UHDG\WREHSDLUHGWRVHOHFWHG
WUDQVPLWWHUV
â/RDG/('LV6ROLGON
Tap the “Pairing” button a thrid time while in pairing
mode:
â/RDGDQG/RDGWXUQONDJDLQ
EOPC-100
Wireless Lighting Control System
Wireless Self-Powered PIR Ceiling Mount
Extended Range Occupancy Sensor
Sensor
28'
30'
COVERAGE PATTERN
7KH(23&SURYLGHVDr
FRYHUDJHSDWWHUQ7KHFRYHUDJH
VKRZQUHSUHVHQWVPD[LPXP
FRYHUDJHIRUZDONLQJPRWLRQDW
DPRXQWLQJKHLJKWRIIHHW
Strong air
supply
6’
Sensor
Mount sensor at least 6’ away from hot air supply.
Avoid obstacles that block sensor’s line-of-sight.
Pendant
xture
,QSXW9ROWDJH .............................6HOI3RZHUHG2SWLRQDO%DWWHU\
2SHUDWLQJ/LIHDW)XOO&KDUJH ............................................ 72 hrs
&RQQHFWLRQWR:LUHOHVV1HWZRUN.......... 7UDQVPLWVVLJQDOWR:DOO
6ZLWFK5HFHLYHU(26:YLD5DGLR)UHTXHQF\
(QYLURQPHQW ................................................. )RU,QGRRU8VH2QO\
 2SHUDWLQJ7HPSHUDWXUH ....................rWRr)rWRr&
 6WRUDJH7HPSHUDWXUH ......................rWRr)rWRr&
 5HODWLYH+XPLGLW\ ........................... WRQRQFRQGHQVLQJ
3DWHQW3HQGLQJ
44 ft
Extended Range Lens (Standard)
EOPC-100
8 ft
22 ft 13 ft 7 ft 3 ft 0 3 ft 7 ft 13 ft 22 ft
Typical
desk-top
level
EOSW-101 Series
TP
OC
“Load Status”
Blue LED
Pairing
Button
MAJOR MOTION
Ideal: 44ft diameter @8ft
Minimum: 35ft diameter @ 8ft
MINOR MOTION
Ideal: 30ft diameter @8ft
Minimum: 25ft diameter @ 8ft
EOSW-102 Series
TP
OC
“Load 1 Status”
Blue LED Off
Pairing
Button
“Load 2 Status”
Blue LED On
EOSW-102 Series
TP
OC
“Load 1 Status
Blue LED ON
Pairing
Button
EOSW-102 Series
TP
OC
“Load Status
Blue LEDs
Pairing
Button
Warning: Do Not Mount in a dark room (< 3 fc).
If necessary, please insert optional battery.
SENSOR MOUNTING
Mounting to junction box:
7KH(23&FDQEHPRXQWHGWRDSUHLQVWDOOHGMXQFWLRQ
ER[XVLQJWKHPRXQWLQJSODWHWKDWLVSURYLGHG
 $WWDFKPRXQWLQJSODWHWRMXQFWLRQER[ZLWKWKH
SURYLGHGVFUHZV
 6QDSWKHVHQVRURQWRWKHPRXQWLQJSODWH
Through ceiling tile:
7KH(23&FDQEHPRXQWHGWRWKHVXUIDFHZLWKWKH
SURYLGHGVFUHZVRUE\XVLQJWKHGRXEOHVLGHGWDSH8VHWKH
SURYLGHGSDSHUWHPSODWHWRPDUNWKHVXUIDFH
Step 3: Pair Occupancy Sensor to Receiver
:KLOHWKHUHFHLYHULVLQSDLULQJPRGHDQGWKHORDG\RX
ZDQWWRSDLUWKHVHQVRUZLWKLVOn:
Tap the “Pair” button on the Occupancy Sensor
â7KHVHOHFWHGORDGVZLOOIODVK2))21IRUYLVXDOSDLULQJ
FRQILUPDWLRQ
Step 4: Exit “Pairing” Mode on Receiver
2QFHDGHYLFHLVSDLUHGZLWKWKHUHFHLYHUWKHUHFHLYHUZLOO
DXWRPDWLFDOO\H[LWÝSDLULQJÞPRGH
â7KHUHFHLYHUZLOODOVRH[LWÝSDLULQJÞPRGHLIQRGHYLFHLV
SDLUHGWRLWZLWKLQVHFRQGV
â3UHVVLQJDQGKROGLQJWKHSDLULQJEXWWRQIRUVHFRQGV
DOVRH[LWVWKHSDLULQJSURFHVV
Note7RSDLUDGGLWLRQDOUHPRWHGHYLFHVWRWKHVDPHORDG
UHSHDW6WHSWRUHHQWHUÝ3DLULQJÞPRGH
Testing the loads paired to the occupance sensor
7RWHVWWKHORDGVSDLUHGWRWKHRFFXSDQFHVHQVRU
Tap the “Pair” buttonZKLOHQRUHFHLYHULVLQÝ7HVWÞ
PRGHWRWRJJOHWKHORDGRQDQGRII
Test Button
Pairing Button
Battery Tray
Sensitivity
Trimpot
Pairing/Transmission
Red LED
TESTING THE OCCUPANCY SENSOR
Ý7HVWÞPRGHDOORZV\RXWRSHUIRUPDVHQVRUZDONWHVWWR
GHILQHWKHFRYHUDJHDUHDRSWLPXPVHQVLWLYLW\VHWWLQJVDQG
product placement.
:DWW6WRSSHUUHFRPPHQGV\RXXVHDEDWWHU\WRSHUIRUP
WHVWPRGHRWKHUZLVHWKHVHQVRUPD\QRWKDYHHQRXJK
power.
,QÝ7HVWÞPRGHWKHVHQVRUWXUQV
OFFDOOORDGVRIUHFHLYHUVZLWKLQ
UDQJHDIWHUVHFRQGVRIQR
GHWHFWLRQDQGEHJLQVDPLQXWH
WHVWSHULRG
Step 1: To Enter Test Mode
Tap the “Test” button on the
Occupancy Sensor
â7KHFRUUHVSRQGLQJ/('RQWKH(26:UHFHLYHUEOLQNVWR
FRQILUPWLPHGHOD\VHOHFWLRQIRUUHFLHYHUVSDLUHGZLWKWKH
VHQVRUWKDWLVLQÝ7HVWÞPRGH
â7KH/('VWRSVEOLQNLQJRQFHWKHVHQVRUH[LWVWHVWPRGH
â:KHQWKHVHQVRUGRHVQÛWGHWHFWPRWLRQDOOORDGV
FRQWUROOHGE\WKHVHQVRUZLOOWXUQOFFDIWHUVHFRQGVRI
RSHUDWLRQ
Step 2: Exit “Test” Mode
â7KHVHQVRUZLOO
DXWRPDWLFDOO\H[LWWHVW
PRGHDIWHUPLQXWHVDQG
HDFKORDGZLOOJREDFNWR
WKHLUVHOHFWHGWLPHGHOD\
GHIDXOWYDOXHRUEDFNWR
WKHXVHUVHWYDOXHLH
/RDG PLQXWHV/RDG
 PLQXWHV
Note7KHPLQXWH
ZLQGRZLVPRUHWKDQOLNHO\WRUHTXLUHWKDWWKHVHQVRUEH
IXOO\FKDUJHGRUXVHWKHEDWWHU\7RPDQXDOO\H[LWÝ7HVWÞ
PRGHWRE\SDVVWKHPLQXWHZLQGRZDQGUHVHWLWEDFNWR
QRUPDORSHUDWLRQ
Tap the “Test” button on the Occupancy Sensor again
â7KHVHQVRUH[LWVWHVWPRGHDQGWKH/('VWRSVEOLQNLQJ
EOPC100 BUTTON
LOCATIONS
Test Button
Pairing Button
Battery Tray
Sensitivity
Trimpot
Pairing/Transmission
Red LED
EOSW-102 Series
TP
OC
“Time Delay
Status”
Green LEDs
Mounting plate
Screws
Junction box
EOPC-100
Snap
Line up screws
with holes in
paper template
Paper
Template
Slide sensor
SENSOR MOUNTING
7KH(23&FDQEHPRXQWHGWRDQ\IODWVXUIDFHRU
SODFHGGLUHFWO\RQWKHVXUIDFH
Mounting to wood or non metal surfaces
 $WWDFKWKHPRXQWLQJSODWHWRWKHGHVLUHGORFDWLRQZLWK
WKHSURYLGHGVHOIWDSSLQJVFUHZRUGRXEOHEDFNHGWDSH
 6QDSWKHVHQVRURQWRWKHPRXQWLQJSODWH
Mounting to metal surfaces
 8VHWKHVXSHUPDJQHWVRQWKHEDFNRIWKHVHQVRUWR
PRXQWWRDQ\PHWDOVXUIDFHVXFKDVIL[WXUHVRUPHWDO
GHVNV
 6LPSO\VQDSWKHVHQVRURQWRWKHVXUIDFH
WARNING:'R1RW,QVWDOO7R&RYHUD-XQFWLRQ%R[+DYLQJ
&ODVVRU3RZHUDQG/LJKWLQJ&LUFXLWV
Double-backed
foam tape
Double-backed
foam tape
Ceiling
Sensor Mount
Snap magnet
to surface
SETTING LOAD PARAMETERS ON THE
RECEIVER
Step 1: Enter Configuration Mode
Press and Hold “Configuration”
Button (C) for 3 Seconds
â/RDGWXUQVON and Load
2 turns OFF. /RDGLVQRZ
DFWLYH
âÝ7LPH'HOD\ÞDQGÝ2SHUDWLQJ
0RGHÞ/('VEHJLQWREOLQNWR
LQGLFDWHWKHLUFXUUHQWVHWWLQJV
IRUWKHVSHFLILFORDG
Note,IQR2FFXSDQF\6HQVRULV3DLUHGWRWKHGHYLFHWKHQ
WKHÝ7LPH'HOD\Þ/('ZLOOEHQRWEHOLW
Step 2: Modifying “Time Delay”
Tap the “Time Delay”
Button (T) to cycle
WKURXJKRSWLRQVRI
PLQPLQPLQ
â&RUUHVSRQGLQJ7LPH'HOD\
/('FRQILUPVWLPHGHOD\
VHOHFWLRQIRUVSHFLILFORDG
Step 3: Modifying “Operating
Mode”
Tap the “Operating Mode”
Button (O)WRDOWHUQDWHEHWZHHQ
Ý0DQXDO2QÞDQGÝ$XWRPDWLF
2QÞVHWWLQJV
â&RUUHVSRQGLQJ/('FRQILUPV
RSHUDWLQJPRGHVHOHFWLRQIRU
VSHFLILFORDG
Step 4: Modfying Load 2
Parameters
TapÝConfigurationÞButton
(C)RQFHWRDOWHUQDWHEHWZHHQ
/RDGV/RDGLVQRZDFWLYH
â3XVKEXWWRQ/('WKDWLVOLW
ZLOOFRUUHVSRQGWR/RDG
EHLQJPRGLILHG
â5HSHDWVWHSDQG
Note,IQRVHQVRULVSDLUHGWRWKHORDGWKHQRQO\Ý2SHUDWLQJ
0RGHÞ/('ZLOOEHOLWDQGZLOOEHRQPDQXDO
Step 5: Exit “Configuration” Mode
â3UHVVDQG+ROGÝConfigurationÞbuttonIRUVHFRQGV
IR airgap switch (not applicable)
“Load Status”
Blue LEDs
1 “Pairing” Green LED
Load Button
Pairing Button
3 “Time Delay”
Green LEDs
Time Delay
Button
2 “Operating Mode”
Green LEDs
Operating
Mode” Button
Conguration Button
EOSW-101 Series EOSW-102 Series
TP
OC
TP
OC
EOSW-102 Series
TP
OC
“Load 1 Status”
Blue LED ON
“Load 2 Status”
Blue LED Off
Conguration
Button
“Time Delay”
Green LED
blinks
“Operating
Mode” Green
LED blinks
EOSW-102 Series
TP
OC
“Load Status”
Blue LEDs
Time Delay
Button
EOSW-102 Series
TP
OC
Conguration
Button
“Load 2 Status”
Blue LED
LOAD PARAMETERS
7KH(26:'HIDXOWVWR0DQXDO2Q$XWR2))
7KH(26:'HIDXOWVWR$XWR2Q$XWR2))
IRU/RDGRU0DQXDO2Q$XWR2))IRU/RDG
* $XWR2))LVHQDEOHGDFFRUGLQJWRWKHVHQVRU7LPH'HOD\ZKHQD
VHQVRULVSDLUHGWRWKHORDGUHJDUGOHVVRIZKHWKHUWKHORDGZDVWXUQHGRQ
DXWRPDWLFDOO\ZLWKRFFXSDQF\RUPDQXDOO\XVLQJDVZLWFK:KHQRFFXSDQF\
LVQRORQJHUGHWHFWHGDQGWKHWLPHGHOD\KDVH[SLUHGWKHORDGZLOOVKXWRII
EOSW-102 Series
TP
OC
Operating
Mode Button
EOSW101/EOSW102 BUTTON AND
LED LOCATION
11/2012
16585rX2
Please
Recycle
2800 De La Cruz Blvd.
Santa Clara, CA 95050
Phone: 800.879.8585
www.wattstopper.com
TROUBLESHOOTING
â ,QDQLQGRRUHQYLURQPHQWWKHZLUHOHVVFRQWUROVKDYHD
W\SLFDOUDQJHRIIHHW$VWKHREVWUXFWLRQVDQGRU
QRLVHLQWHUIHUHQFHLVOLJKWHURUKHDYLHUWKHUDQJHZLOOEH
more or less.
â 1RLVHLQWHUIHUHQFHFDQEHHLWKHUOLQHQRLVHIURP
PRWRUVRU5DGLR)UHTXHQF\5)
â 6ZLWFKHVJRLQWRDUHGXFHGUDQJHPRGHZKHQLQ
SURJUDPPLQJXQGHUIHHW
â 5DQJHFDQEHUHGXFHGE\RYHUORDGLQJWKHVZLWFKVZLWFK
LVRQO\UDWHDW$
â 5DQJHFDQEHUHGXFHGE\PHWDOREMHFWVPHWDO
GHFUHDVHVWKHHIIHFWLYHQHVVRI5)WUDQVPLVVLRQ
â 2XWSXWSRZHULVUHJXODWHGE\WKH)&&
â 5HFHLYHUVHQVLWLYLW\LVIL[HG
â )L[HG$QWHQQDVDUHLQWHJUDWHGLQWRWKHSURGXFW
&RQVLGHU)DFWRUV$IIHFWLQJWKH(QYLURQPHQW
â 'HYLFHSODFHPHQW
â 2EVWUXFWLRQVPHWDOFRQFUHWHRWKHUFRQVWUXFWLRQ
PDWHULDOV
â ,QWHUIHUHQFH
2EVWUXFWLRQV
â 'RHVWKHV\VWHPZRUNPRUHUHOLDEOHDWFORVHUDQJH
ZLWKRXWREVWUXFWLRQV"
â ,GHQWLI\QHDUE\PHWDOFRQFUHWHDQGRWKHUREMHFWV
SRVVLEO\DIIHFWLQJVLJQDOVWUHQJWK
â &DQHLWKHUGHYLFHEHUHORFDWHGHYHQVOLJKWO\DZD\IURP
REVWUXFWLRQVWRLPSURYHWKHV\VWHPSHUIRUPDQFH"
,QWHUIHUHQFH
â 'RHVWKHV\VWHPZRUNEHWWHUDWFHUWDLQWLPHVRIWKH
GD\"
â /RRNIRUSLHFHVRIHTXLSPHQWWKDWPD\DIIHFWZLUHOHVV
SHUIRUPDQFHZKHQWKH\DUH21
â 7U\XVLQJDVLJQDOVWUHQJWKPHWHUWRPHDVXUH0+]
5)QRLVHIORRUDQGTXDQWLI\SDFNHWUHFHLYLQJUHOLDELOLW\
3URGXFWYDULDWLRQV
â 5HSODFHRQHSLHFHRIKDUGZDUHDWDWLPHWRLVRODWHDQ\
YDULDWLRQLQSURGXFWSHUIRUPDQFH
Sensor does not learn:
â3OHDVHFKDUJHIRUPLQXWHVLQLQGRRUOLJKWRUVXQOLJKW
EHIRUHDWWHPSWLQJWRXVHRULQVHUWRSWLRQDOEDWWHU\
6HQVRUGRHVQRWFRPPXQLFDWHWRUHFHLYHU
â &KHFNSDLULQJRIWKHVHQVRUDIWHULQVWDOODQG
FRPPLVVLRQLQJSUHVVWHVWEXWWRQWRWHVWWKHUDQJH
:,7+$&+$5*('6(1625LIWKHORDGWRJJOHVWKH
UDQJHLVJRRG,IWKHORDGGRHVQRWWRJJOHSXOOWKH
VHQVRURIIWKHFHLOLQJYHULI\FKDUJHE\VHHLQJWKH/('
RQWKH6(1625IODVKWKHQSUHVVWHVWEXWWRQWRWHVWZLWK
WKHGHYLFHFORVHWRWKHUHFHLYHULIVWLOOQRORDGWRJJOH
WKHGHYLFHLVHLWKHUQRWFKDUJHGRUKDVQRWEHHQSDLUHG
SURSHUO\RUPD\KDYHHYHQEHHQXQOHDUQHGVHHSDLULQJ
VHFWLRQDERYH
,IGHYLFHVWLOOGRHVQÛWUHVSRQG
â 0DNHVXUHWKHVHQVRULVXQSDLUHGWRWKHUHFHLYHUE\
SODFLQJWKHUHFHLYHULQWRSDLULQJPRGHWKHQWDSSLQJWKH
SDLULQJEXWWRQRQWKHVHQVRUWKUHHWLPHV
5(9 '(6&5,37,21 ,17 5(9'$7( $33529('
X1 (&2& &5  &*
; (&2&;;;; &5  &*
TITLE BOX PAGE ONLY.
'21270$.(),/0â'212735,17
MATERIAL: White 80g/m sq
Uncoated, recycled stock preferred
Final Trim Size: 17” (Wide) x 11” (High)
Ink: CMYK
Print: Two Sides
# Pages: 4
# Sheets: 2
,)<28+$9($1<48(67,2165(*$5',1*63(&,),&$7,216255(48,5(
$'',7,21$/),/()250$77,1*3/($6(&217$&7(QJLQHHULQJ
$OOLQIRUPDWLRQLQWKLVGUDZLQJLVWKHSURSHUW\RI:DWW6WRSSHU
DQGFDQQRWEHFRSLHGRUXVHGZLWKRXWWKHZULWWHQDSSURYDORI
:DWW6WRSSHU
Finish1
Fold 3
Fold
2
Fold
17”
2.75”
11” 8.5”
4.25”
Drawn by: ROBERTSON:
PLM: EU
Tech Writing: CR
Eng: AF
QA
TITLE BOX PG. Scale: 1 : 1
Title: EOPC-100 Quick Start Guide
Drawing #: Original Drwg. Date: 08 DEC 11 Rev #:
16585 Rev. Date: 13 NOV 12 X2
SANTA CLARA, CALIFORNIA

Navigation menu