Third Millennium Systems AV90 Access Control Reader, Model AV90 User Manual

Third Millennium Systems Ltd. Access Control Reader, Model AV90

User Manual

3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129+1 303 475 4972 sales@3millid.com© 3millID100-02638-A www.3millid.comImages shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice.Product FeaturesDesigned  to  embrace  cutting-edge  RFID technologies  in  a  stylish  and  innovative package, this advanced access control reader offers  a  refreshing  breakthrough  in  the  access security  marketplace. Shaped  in  a  sleek  mullion style  design,  the  reader  may  be  mounted  to  most plain wall finishes.This  powerfully  secure  and  innovative  reader  has  a beautifully clean  aesthetic, and a  bright RGB LED  that can be applied  to  many  applications  such  as  colour  coded  access  levels, migration status or mood lighting.The reader housing is moulded using tough polycarbonate plastic, and includes a shadow-line backplate, a subtle and simple mechanical design feature that makes the reader, when fixed, appear to float against the wall.•125KHz Proximity•13.56MHz Smart Contactless•Bluetooth LE•Black textured moulding•Slim profile•RGB LED•Fully encapsulated electronics•Wide range of output formats•5 year limited warranty•Read range up to 10cm (4 inches)MANUAL3MMullionstyle or technology - now you can have both
3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129+1 303 475 4972 sales@3millid.com© 3millID100-02638-A www.3millid.com3millID  acknowledges  all  copyrights  and  registered  trademarks  used by  third parties.  No affiliation  is  implied,  or should  be inferred, to the use of any tradename or reference to copyright material.Any  reference  to  copyright  material  or  registered  trademarks  within  this  document  is  used  purely  to  depict  or  identify  such material  for  the  purpose  of  comment,  description  or  comparison,  and  to  assist  in  the  evaluation  of  products  or  services described herein.No part of this publication may be reproduced or translated into other languages or transmitted into a language used by data processing machines without the express written consent of 3millID.E&OEWe do our best to provide accurate and reliable information at the time of publication, but due to continuous developments we cannot be  held  responsible for clerical  errors, omissions or  outdated  information, and  we  reserve the right  to amend, alter  or withdraw such information, without notice.Images shown in this document are for illustrative purposes only. The features, colours, style and appearance may change without notice.EQUIPMENT*******These  devices  comply  with  Part  15  of  the  FCC  Rules. Operation  is  subject  to  the  following  two  conditions:  (1) this  device  may  not  cause  harmful  interference,  and  (2) this  device  must  accept  any  interference  received, including  interference  that  may  cause  undesired operation.Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.These devices contains: FCC ID: TCZ-10103751G1UTJ-AV90These RFID proximity readers comply with the essential requirements and relevant provisions of:EU Directive 2014/53/EC.Together  with  information  provided  by  suppliers  and subcontractors,  these  devices  comply  with  the requirements and relevant provisions of:EU Directive 2011/65/EC.This symbol on the product or on its packaging indicates that  the  product  must  not  be  disposed  of  with  normal household  waste.  Instead,  it  is  your  responsibility  to dispose of your waste equipment by arranging to return it  to  a  designated  collection  point  for  the  recycling  of waste electrical and electronic equipment. By separating and  recycling  your  waste  equipment  at  the  time  of disposal you will help to conserve natural resources and ensure that the  equipment  is recycled  in a manner that protects human health and the environment.EU Directive 2012/19/ECSECTION TITLE PAGE1. Parts List         32. Specification         33. Installation Guide        4 2CONTENTSMANUAL3MMullionstyle or technology - now you can have both
3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129+1 303 475 4972 sales@3millid.com© 3millID100-02638-A www.3millid.com1   x reader MODULE1   x reader BACKPLATE1   x 3 x 10mm black cross-head securing screw10cmup to+ -6635C5yrs1. parts list2. specificationperformance level for access controlThis product complies with the following UL294 Access Control Performance Levels:Destructive Attack Level ILine Security Level IEndurance Level IVStandby Power Level ISee the UL Listed access control unit controller installation instructions for reader compatibility.UL Ref. Number ??????environmentalOperating Temperature -35°C to +66°C  (-31°F to + 151°F)Humidity 85 ±5% at 30 ±2°C   (86 ±3°F)Ingress Protection IP65  (not evaluated by UL)Positioning Suitable for INDOOR and OUTDOOR use.electricalPower supply Power is to be provided by a UL294 Listed, low-voltageClass 2 power limited supply or control panel, capableof 4 hours standby.Voltage +10Vdc to +16VdcCurrent 70mA typicalData Voltage Rest >4Vdc / Active <1VdcData Output Wiegand, Clock & Data, Custom OutputsIndication 1 RGB LEDSounder Integral speakerdimensions 96mm x 52mm x 21mm (3.8 x 2.1 x 0.8 inches)polymeric materialsPotting compound UL R/C (QMFZ2)Mouldings UL746Cwiring Wiring methods shall be in accordance with theNational Electrical Code (ANSI/NFPA70), localcodes, and the authorities having jurisdiction.Recommended cable BELDEN 953x (or equivalent UL listed) - WiegandBELDEN 9502 (or equivalent UL listed) - RS485All cable and wiring must be Listed and suitable for use.Cable length Cable length must not exceed 30 metres maximum(98.5 feet) for ULMinimum permissible wire size not less than 26 AWG (0.24mm²)connectionsScrew terminal (All readers in this series use this terminal connection) 1 - 0V Supply voltage ground 2 - +Vdc Supply voltage (+10Vdc to +16Vdc) 3 - DATA1/CLK Wiegand or Clock/Data output 4 - DATA0/DAT Wiegand or Clock/Data output 5 - GREEN Green LED control input 6 - RED Red LED control input 7 - Buzzer Buzzer control input 8 - TMPR/CP Tamper or Card Present output 9 - RS485- RS485 Bus10 - RS485+ RS485 Bus96mm3.8 inches52mm2.1 inches21mm0.8 inchMANUAL3MMullion3
3millID   9249 S. Broadway   Building #200   Suite 826   Highlands Ranch   CO 80129+1 303 475 4972 sales@3millid.com© 3millID100-02638-A www.3millid.comRemove module securement screw. Lever bottom edge of reader module away from the backplate, and lift up.Fix reader BACKPLATE to a plain surface finish, using suitable screw fixings having a diameter no greater than 4mm (0.15 inch).If printed full scale, you may use the drawing below as a fixing template.MEASURE and CHECK DIMENSIONS before use.NOTE:Mounting this reader on (or near) metal may impair the read range of the unit.3. installation guideFasten the reader module, ensuring the top-edge fixings engage correctly with therecesses at the top of the backplate. Swing the bottom edge of the module downand forward until you feel the unit ‘snap’ shut.Secure the module to the backplate using the M3x10mm screw supplied.If required, you may opt to use a security screw to the sizes shown here.Following installation, it is recommended the access control system and controlunits are subjected to a maintenance and operational test procedure.TEST COMPLETE SYSTEM AT LEAST ONCE A YEAROnce the backplate is secured, make wire connections to the reader, in accordance with the screw terminal connections shown onPage 3 of this document and your control panel requirements. Ensure the cable does not impair or prevent the reader module being secured.i12i3i12365mm2.7 inches34.4mm1.4 inches49mm1.9 inches13mm0.5 inchFixing holes - 4mm maximum diameter.Cable-feed aperture.Module fixing insert.MANUAL3MMullion4

Navigation menu