Thomson Broadcast and Multimedia 8BUSBM-250A User Manual 33722

Thomson Broadcast & Multimedia, Inc. 33722

8

Download: Thomson Broadcast and Multimedia 8BUSBM-250A User Manual 33722
Mirror Download [FCC.gov]Thomson Broadcast and Multimedia 8BUSBM-250A User Manual 33722
Document ID33722
Application IDCpLy2PRKkU/LRIgfd+xVzg==
Document Description8
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize42.85kB (535613 bits)
Date Submitted1999-04-22 00:00:00
Date Available1999-10-14 00:00:00
Creation Date2001-06-28 11:00:15
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2001-06-28 11:00:17
Document Title33722.pdf
Document Author: jsoscia

f.‘ comm“ SBM-250 Technical Manual
Am—ucmw-ny
TECHNICAL MANUAL
DOC33-0008
—
0 COMWAVE
FIGURE 10-0010-l
Released by: Paula Curran
12mm ,
Checked by: Danni Win
Created by: Kimbefly Simeon:
12/22/93
{Ml/96 ECO #: 98-164
lineman" ll: 00010-0010
REV.“ B ' '
a OOMWAVE Warranty lnfanmrrian
__AM—————_———-—
COMWAVE TWO YEAR LHVIITED WARRANTY
Comwave warrants each product of its manufacture to be free from any defect in material
and workmanship for a period of two years after delivery to, and return by the original
purchaser. No returns, however, will be accepted unless accompanied by a written
factory return authorization.
The limit of liability under this warranty shall be to repair or replace any product, or part
thereof, which proves to be defective afier inspection by Comwave with the exception of
tubes, semiconducmt devices, lamps, fuses or equipment (i.e. modulators) manufactured by
others, which are subject to only such loss adjustment as Comwave may obtain for the
suppliers thereof.
This warranty shall not apply to any Comwave product which has been modified, physically
or electrically damaged, or to modules which seals have been broken, or any product which
has been subjected to conditions exceeding the applicable specifications or ratings or
improper service techniques.
Comwave will not be liable for any direct or consequential injury, loss or damage incurred
through the use, or the inability to use, any Comwave product.
Comwave reserves the right to make design changes to any Comwave product without
incurring any obligation to make the same changes to previously purchased units.
This warranty is the full extent of the obligation and liability assumed by Comwave with
respect to any and all Comwave products. Comwave neither makes, nor authorizes any
person to make, any other guarantee or warranty concerning Comwave products.
Cream! by: Kimberly Simeon: Checked by: Jmm‘ ”10”ng
4/98 9/4/96
Document if: MGR-0001
REV: A "
Released by: mnau Wilt: '
ran/9 ' rude Coma 1mm
Table of Contents
M®
74m Hurllr M.
SYSTEM OVERVIEW
FCC ID
SYSTEM BLOCK DIAGRAM
SYSTEM SPECIFICATIONS
INSTALLATION
TURN—ON GUIDE
TROU BLESHOOTING
FUSING AND PROTECTION
MAINTENANCE
CALIBRATIONS
THEORY OF OPERATION
RACK
DRIVER
FINAL (rowan AMPLIFIER SEGMENT)
SCHEMATICS
CUSTOMER SERVICE
OPTIONS
f.‘ 00me Table omelmm
M—
TABLE OF CONTENTS
For the SBM-250 Transmitter
SBM-250 Cover Sheet ....... DOCIO-OOIO
SBM-250 system Figure 10-0010—1
Warranty ........................ ...DOCl2-0001
SECTION]
Section 1 Introduction .................................................................................... DOC11-0006
SBM-ZSO, SBM-SOO, SBM-500/250, SBM-SOO/SDO
Top Level Description .. ....DOC13-0025
Rack Assembly .. DOC22-0009
DOC22-0012
DOC15—0009
DOC15-0025
Block Diagram of Rack — Single Transmitter
SBM-250 Detailed Block Diagram, Single Output ..
Specifications for the SBM Series ................................................................. DOC19-0019
SECTION 2
Section 2 Introduction .................................................................................... DOC1 1-0007
Installation .........
Unpacking
Physical Installation
Rear door
AC power connections to the exhaust fans
Driver chassis
Power amplifier segment
Enviromnental and safety considerations
DOC17-0007
AC Loading in an HPB/SBM System ................ DOC17-0012
3-lese DELTA Connected System figure 17-00124
Outlet Strip Configuration . “Figure 17-0012-2
MTS-3 Power Shelf ....... ..Figure 17-0012-3
AC System ........................................... “Figure 17-0012-4
HPB/SBM Three Phase AC Loading DELTA Co iguratio ................. DOC24-0006
Cabling .............................................................................. DOC18-0017
Driver
Reference Distribution
Created by: Khnberly Simeane Checked by: Donald Wile Released by: Paula Carrea
11/20/93 ' 11/20/93 11/20/93
Doeunlall ll: 00011-0014
REWA k |
a OOMWAVE Table afConrents
Amwm
IF Distribution
Comview Interconnections
VHF/UHF Block Upconverter (driver) Cabling Diagram. ..DOC23-0045
SBM Series System Interconnection .......................... ..DOClS-0026
Turn-On Procedure ........................................................................................ DOC26-0004
Initial Operation Procedure
Normal Operation Procedure
SECTION 3
Section 3 Introduction... ............................................... DOC] 1-0008
Troubleshooting ............................................................................................. DOC18-0018
Driver
Analog metering
Power amplifier segment
Troubleshooting Worksheet ........................ .. .DOC18-0022
Power Amplifier Segment Node Addresses ...DOC22-0019
Equipment Fusing and Protection ............... DOCl8-0015
Table of Fuse Locations and Value Figure 18-0015—1
Circuit Breaker .......... Figure 18—0015-2
AC Power Interconnections . DOC13-0029
AC Power Intermnnecuons B 00 iagram ................ Figure 13—0029-1
66-310-01
DOC] 3-0030
Figure 13-0030-1
AC Interconnect HPB/SBM Series 1 Phase & 3 Phase AC power.
DC Power Connections ......................................
DC Power Connections Block Diagram
Rack Power Supply (AC to DC front end converter)
for High Power Series ..
DC to DC Converter
Motherboard located in Subrack of the High Power Series
Interconnect, DC SD/SDA series (high power)
RF Power Interconnections ...........................
RF Signal Path for Redundant System“
Figure 13-0030-2
Figure 13-0030—3
figure 13-0030—4
.66-304—01
.DOClB-0054
Figure 13-0054-1
Maintenance ........................................................................ DOC 1 8-0005
Inspections
Cleaning
Power Amplifier Segment Picture .......... ..Figure 18-0005-1
Monthly Maintenance Record ..................................... ..DOC18-0016
Metering Calibration ...................................................................................... DOC 16-0005
Digital Metering
Analog Metering
Power Specification Chan ................................................................. Figure 16-0005—1
Reflected Output Power Metering
Document #: DOCII—0014 2_
REV: A
f“ WAVE Table amelrenLv
Rear Panel Switch and Control Drawer ............................................. Figure 16-0005-2
+1 lV Switching Power Supply Metering
Potentiometer Locations ...Figure 16-0005—3
SBM Series Calibrations ........ DOC23-0042
Power Calibration Test Setup ...DOC22-0018
SECTION 4
Section 4 Introduction ................................................................................... DOC1 1-0009
Rack theory of operation ........... DOCl4—0005
Photo of Rack ......... Figure 14-0005-1
SBM/HPB rear View .i DOC23-0046
Sub-rack theory of operation ............... DOC 14—0006
Photo of Suhrack ..................... Figure 14-0006-1
Motherboard to System Interface
Motherboard (35-080) Photo ............................................................. Figure 14-0006-2
Module to Motherboard Interface
VHF to Microwave Drawer Theory of Operation (20—346-2gxx-02) ............ DOC14-0007
Front Panel Features
Rear Panel Features
Driver Block Diagram .......................... 66-321-01
DOC23-0038
.DOC23-0039
.66—323-01
.DOC19-0027
.DOC13-0060
Front Panel .
Rear Panel ..
Internal Interconnect VHF to uW, Comview Ready.
Specifications — SBM Series Driver Specs
Local Oscillator Multiplier (08-013) .
Photo ......... .Figure 13-00604
Specifications DOC 19-0030
VCXO, PLL (09-060) .. ‘DOC13-0059
Photo ......... .Figure 13-0059—1
Specifications DOC19~0031
Bandpass filter (05-025) .. .DOC13-0063
Photo ................ .Figure 13-0051-1
90019-0022
.DOClB-0057
..Figure 13-0057-1
“Doom-0028
..DOC13-0066
Bandpass filter specifications
Amplifier with ALC (04-305 & 314-02) t.
Photo.
Specifica ons, RF and DC
VHF/UHF ALC Module (04-326).
Photo ............ ..Figure 13-0066-1
Specifications 4. ..DOCl 9~0032
Mixer - OEM .4DOC13-0065
Photo
Specifications..
Bandpass filter (OEM)
figure 13~0065-2
Figure 13-0065-1
ocmmso
Dacron!!! it: DOCIJ-MM , . 3
REV: A
f.‘ eommvs
Table afCamer
ml_—————_——_
Photo ................................. ..Figure 13-0050-1
Bandpass filter specifications DOC19-0021
Immediate power amplifier (04-306 & 313-02) .. OC13-0052
Photo ........ igure 13-0052-1
DOC 1 9-0023
DOC 13-0058
Intermediate power amp specr cations (RF and DC specs).
Envelope detector (12-032) .......
Envelope detector picture . igure 13-0058—1
Broadband RF Precorrector (04—299) DOC13-0062
Photo, Top View Figure 13-0062-1
Photo, Side View Figure 13-0062—2
Specifications ..... DOC19-0026
Intermediate power amplifier (04-308-02) . DOC13-0053
Photo ........................................ Figure 13-0053-1
Intermediate power amp specifications (RF and DC specs)
Motherboard (35-096) .............................
Microcontroller Interface board (34-006)...
Firmware Flowchart VHF/UHF to uW Upconv er.
Chassis Monitoring and Control Functions ...........
List and Description of Parameters Monitored in
VHF/UHF to uW Upconverter Chassis .. ...DOCZ4-0010
Signal distribution board (33-312) DOC13-0064
Photo ..................... Figure 13-0064-1
Input/Output Signals. Figure 13-0064-2
118485 Communications Board (33- -284 & 33— 304) DOC13-0009
33- 284 Photos. '
33-304 Photos
Comview Status Monitoring Interconnections ..
DOC19-0024
DOCl3-0055
...DOC13-0056
...DOC21—0003
...DOC13-0071
Power Amplifier Segment Theory of Operation (04-294-2gxx-02)
Power Amplifier Segment Photo
Power Amplifier Segment Specifications.
Power Amplifier Segment Block Diagram
Internal Interconnect, Power Amplifier Segment.
Power Amplifier Board (40-220) ..................
Power Amplifier Board Specifications .
Power Amplifier Board Block Diagram
300 Watt Power Supply Board (32- -002)
300 Watt Power Supply Board Specrflcations.
Power Supply Block Diagram
Control Board (34-010)...
Control Board Spect cations.
Control Board Block Diagram
Firmware Flowchart.
Amplifier Segment State Flow Diagram
RS- 232 Communications Board (33— —352)
' Photo ......................................
Figure 14—0008»!
DOC] 9-0014
.DOC15-0013
.66-306-01
.DOC13-0041
.DOCl9-0015
.DOC15-0014
.DOCl 3-0043
.DOCl9-0017
DOC 1 5-001 6
.DOC13-0042
.DOCl9-0016
.DOCl 5-0015
.DOC21-0005
.DOC21-0006
..DOC13-0010
..Figure 13-0010-1
Document #: DOC] 1-0014 4
REV: A ' ‘
f.‘ CONWAVE Table offal-tents
Ammm
SCI-[EMATICS
Sub-Rack:
Motherboard, Back Panel for HPSC tx
Comview/ CPU Controller Interface ..
Driver:
VCXO, PLL (09-060) .................. 09—053-01
Lock indicator/control board 33-301 -01
Envelope Detector (12-032) ...... 33—461-01
Motherboard (35-096) .......
RS-485 Comm. & ctrller I/F
Signal Distribution Board . 33-312—01
Display Board SBSA-ZOC 33-314-01
Power Amplifier Segment:
From Panel Display with Diagnostics Port .................................................... 33-3 52-01
SECTION 5
Section 5 Introduction DOCl 1-0010
Customer service ....... DOC20-0001
Contact information
Equipment returns
Packaging for return (driver) ..................... DOC20—0002
DOC20-0003
Packaging for return (power amp segment)
Document #: DOCH-Mll 5
REV:A ‘
Sectian 5 Intmducflnn
SECTION 5
This section will give you the information you need to contact Comwave customer
service and retum equipment for repair.
Checked by: Dmmld Witt
yams _
Created by: Kimberly Simeon:
9/1 7/98
pow-mu at: 00011-0010
REV: A -
a com“ Customer Service
Amoum
CUSTOMER SERVICE
Camwave’s customer service personnel are available 24 hours a day to assist with any
questions or complications that "my arise. After regular business hours, 3-5 Monday through
Friday, an answering service will answer calls and forward messages to the appropriate
person
Comwave
Cmtwood Industrial Park
395 Olkhlll Road
Mou '
1-570-474-6751 \ lntematlo
(Pink mm. u of 11/98. a are! code elm-gel! 7l
EQUIPMENT RETURNS
In the event the equipment requires return for factory service, please follow the
guidelines listed. Comwave cannot be held responsible for damaged equipment received
due to improper packing. Contact Comwave with any questions or concerns regarding
returning or packaging of equipment.
1. Contact Comwave: Call Comwave to report the problem and to obtain a “Return
Authorization” number (RA). This enables Comwave to accurately track and identify
returned equipment for prompt and efficient service. If you do not obtain an RA
number prior to sending equipment back Comwave cannot be held responsible for
delays in receiving the equipment. These delays will inevitably cause time loss in
repairing and returning your product to you.
2. Obtain packaging materials: Use original boxes and packing materials when
returning any equipment. This will safeguard against most ill-transit damages. If
original boxes and packing materials are not available, contact Comwave to obtain
replacement materials prior to shipping. Replacement materials are provided at a
nominal cost.
3. Pack egyp' ment: Use original packing materials and directions provided. Most
equipment is packed in a box within another box; this varies with each product.
Double boxing provides maximum protection.
Caution: Do not pack equipment using "PEANUIS. ' Equipment packed using “PEANUTS” as
filler does NOT provide sufiicient protection during shipping. Rough handling by the carrier may
cause permanent damage to the equipment being returned. COM WA VE cannot be held responsible
for damaged equipment received due to improper packing.
Created by: Khnberly Simeon: Checked by: Kevin Harding MM!" by: 00511“ W“ '
11/3/93 £00 it: 93-164 ' g 12/1410: _ 12/10/93
Document e.- poem-own
REV: c
0 COMMVE Return Packers-bug
Atlanta-m
PACKAGING FOR RETURN
1. Start with an empty box, figure 20—0002-1, from Comwave, if you don’t have one
please inform customer service when you contact them for a return authorimtion
(RA) number, which you MUST do prior to
returning ANY equipment. A box consists of 4
parts, one cardboard box, one cardboard tube, and
two polyethylene endcaps, see figure 20-0002-2. If
you need to assemble a flattened box, use 2” clear
box tape over the bottom seam, using three layers,
to assure strength. Then put 4 pieces of fiberglass
strapping tape over the edges.
2. Place the cardboard tube in the box as shown in
figure 20-0002-3.
3. Place the polyethylene endcaps against the sides of
the equipment as shown in figure 20-0002-4. WOTE
the front panel fit: snuggly into a slotted opening in the
endeap.
4. Put the transmitter into the box with the cardboard FIGURE 20-0002-1
tube already in it as shown in figure 20—000245.
5. Close the box and seal the top seam with 2” clear box tape, using three layers to
assure strength. Then put 4 pieces
of fiberglass strapping tape over
the edges. Clearly mark the RA
number on the outside of the box
before shipping.
FIGURE 20-0002-2
Checked by: Shawn Ball! ~ v
[MI/75
Released by: Paula Carma
10/21/98
Created by: Kimberly Shawna -~
10/21/98 ECO #: 98-1116
I ' Dominant it: 00020-0002
REV: B
u comm“ Realm Packaging
M—————-——
FIGURE 20-0002-3
FIGURE 20-0002—4
mm.“
FIGURE 20-0002-5
Document it: Doom-0002
' REV: B '
f.‘ WAVE Return Packaging uftlre PawAnwlr‘f‘m Segment
M'—
RETURN PACKAGING OF THE POWER AMPLIFER SEGMENT
1. Start with an empty power amplifier segment
box, shown in figure 20-0003-1. If you don’t
have one please inform Comwave customer
service when you contact them for a return
authorization (RA) number, which you
MUST do prior to returning ANY equipment.
2. Place the power amplifier segment into the
box, as shown in figure 20-0003-2. The
heatsink should always face up and the
connectors on the rear of the power amp
segment rest against the sofi gray foam for
protection
FIGURE 20-0003-1
3. Fold the edges of the inner box in and
close.
4. Place the inner box into the 4-paek
master (outer box), being sure to include
three empty power amplifier boxes for a
secure fit, as shown in figure 20-0003-3.
The power amplifier segments are
generally
packed 4
per master
box and
shipped.
FIGURE 20-0003-2 When [Gunning
segment(s) please pack
them the same way, ALL boxes will be returned to
you. If you need to assemble a master box, use 2”
clear box tape over the bottom seam1 using three layers
to assure strength. Then put 4 pieces of fiberglass
snapping tape over the edges.
5. Close the 4-pack master box and seal the top seam with
2” clear box tape, using three layers to assure strength.
Then put 4 pieces of fiberglass strapping tape over the
edges. Clearly mark the RA number on the outside of
the box before shipping.
FIGURE 20-0003—3
Created by: Kimberly Simeon:
10/21/90 ECO it: 98-116
Document if: 064:sz
RE V: E I

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2001:06:28 11:00:15
Producer                        : Acrobat Distiller 4.0 for Windows
Author                          : jsoscia
Title                           : 33722.pdf
Modify Date                     : 2001:06:28 11:00:17-04:00
Page Count                      : 13
EXIF Metadata provided by EXIF.tools
FCC ID Filing: CHP8BUSBM-250A

Navigation menu