Topcon WT100 Wireless Terminal User Manual WT 100 E 20110221

Topcon Corporation Wireless Terminal WT 100 E 20110221

User Manual

INSTRUCTION MANUALWIRELESS TERMINALWT-100• Thank you for purchasing the TOPCON WT-100 Wireless terminal.• Please read this operator's manual carefully before using this product.• The specifications and general appearance of the instrument, and the content of this manual are subject to change without notice.• Some of the diagrams shown in this manual may be simplified for easier understanding.For the safe use of the product and prevention of injury to operators and other persons as well as prevention of property damage, items which should be observed are indicated by an exclamation point within a triangle used with WARNING and CAUTION statements in this instruction manual.The definitions of the indications are listed below. Be sure you understand them before reading the manual's main text.Definition of IndicationDefinition of IndicationGeneralC WARNINGPower SupplyC WARNINGC CAUTIONWireless technologyC WARNINGPrecautions• Confirm battery remaining level before operating.• Do not leave the instrument under strong sunlight for a long time. It maycause the instrument to malfunction.• When transporting the instrument, provide some protection to minimize therisk of shocks. Heavy shocks may cause the measurement to be faulty.• The instrument can not be submerged underwater. WT-100 is designedbased on the International Standard IP54, therefore it is protected from thenormal rainfall.• Remove the battery from the instrument when you would not use it for longperiod. If this instrument with the battery set in it is stored, the electrolyte mayleak to cause a trouble.• Always clean the instrument after use. If the instrument becomes wet fromrain, dry moisture. To clean the instrument, dust off well and then wipe cleanwith a soft cloth.• To remove the dust on the surface of the parts made by plastic, never usethinner or benzine. Use a clean cloth moistened with neutral detergent.• This product is for professional use only!The user is required to be a qualified surveyor or have a good knowledge ofsurveying, in order to understand the user and safety instructions, beforeoperating, inspecting or adjusting.• Wear the required protectors (safety shoes, helmet, etc.) when operating.• The user of this product is expected to follow all operating instructions andmake periodic checks (hardware only) of the product's performance.• The manufacturer, or its representatives, assumes no responsibility for resultsof faulty or intentional usage or misuse including any direct, indirect,consequential damage, or loss of profits.• The manufacturer, or its representatives, assumes no responsibility forconsequential damage, or loss of profits due to any natural disaster,(earthquake, storms, floods etc.), fire, accident, or an act of a third party and/or usage under unusual conditions.• The manufacturer, or its representatives, assumes no responsibility for anydamage (change of data, loss of data, loss of profits, an interruption ofbusiness etc.) caused by use of the product or an unusable product.• The manufacturer, or its representatives, assumes no responsibility for anydamage, and loss of profits caused by usage different to that explained in theoperator's manual.• The manufacturer, or its representatives, assumes no responsibility fordamage caused by incorrect operation, or action resulting from connecting toother products.• Wireless terminal WT-100  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 unit• Battery BT-66Q . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 pc.• Instruction manual  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 sheet• Battery Charger BC-30D, AC/DC Converter AD-14, AC cable• Tilt holder model-4• Cable for connection to an external battery 1. Push down the battery cover lug to remove the battery cover.2. As illustrated, load the battery BT-66Q along the contact's direction.3. Fit the lugs of the battery cover to the holes first.  Then, push the battery cover lug until the cover is locked.$:• Attach a ferrite clamp filter (ZCAT2035-0930 or equivalent) to the power cablewhen using an external battery. Always wind the cable through the clamp filter in a single loop.Do not remove the ferrite clamp filter from the cable. Removal of the ferrite clamp filter may cause harmful interference and will void the user’s authority to operate this equipment.1. Turn on the power.Press the power switch.Power LED lights.  Make sure Wireless LED, System LED and Power LED light up on the front surface.$:• When the LED does not light or flash, check if the battery is securely inserted.2. Wireless LAN connectionConnecting to Imaging Station IS seriesCRefer to the description about setup of wireless LAN in the IS series instruction manual.Connecting to Data Collector FC-250CRefer to the description about use of wireless LAN in the FC-250 instruction manual.$:The factory default setting of WT-100 is shown below.• SSID1: WT-100-W6zzzz• Encryption key: Not used.• Encryption scheme: Not used.• Wireless channel: Auto *"W6 zzzz" is the same as the serial number on the bottom of the instru-ment.In the following cases, it is necessary to initialize WT-100.• Can't connect even after checking how to connect or the setting of the product(IS series, FC-250, etc.) that should be connected to WT-100.• When you change IP address of this instrument and forget the IP address.• When you want to change the setting back.G:• All setting contents will be deleted upon initialization.  So please write downany necessary information beforehand.zWhen you want to carry out initialization, contact the Topcon head office or your local Topcon dealer.Wireless functionCommunication range:Approx. 300m (This is applied when IS2 is used.  This can be changed depending on any obstacle between the communicating instruments or ambi-ent conditions.)Support format: IEEE802.11g, IEEE802.11bChannel:11 (1 - 11ch)Band: 2.4GHz (2412 - 2462MHz)Network speed:IEEE802.11g: 54Mbps (Max.)IEEE802.11b: 11Mbps (Max.)Transfer mode:IEEE802.11g: Orthogonal Frequency Division Multiplexing (OFDM)IEEE802.11b: Direct sequence spread spectrum (DSSS)Access mode: Infrastructure modeSecurity:WEP (64/128bit)WPA-PSK (TKIP/AES)WPA2-PSK (TKIP/AES)Hidden SSID (Enable/Disable)Software functionLAN setup mode:Fixed IP address (Manual setting)DHCP server (Enable/Disable)Routing function: Dynamic routing, Static routingPRECAUTIONS FOR SAFE OPERATIONC WARNING Ignoring this indication and making an operation error couldpossibly result in death or serious injury to the operator.C CAUTION Ignoring this indication and making an operation error couldpossibly result in minor injury or property damage.JThis symbol indicates items for which caution (hazard warnings inclusive) is urged. Specific details are printed in or near the symbol.DThis symbol indicates items which are prohibited. Specific details are printed in or near the symbol.IThis symbol indicates items which must always be performed. Specific details are printed in or near the symbol.PRECAUTIONSDDo not use the unit in areas exposed to high amounts of dust or ash, in areas where there is inadequate ventilation, or near combustible materials. An explo-sion could occur.GDo not perform disassembly or rebuilding. Fire, electric shock, or burns could result.DDo not short circuit. Heat or ignition could result.DDo not place articles such as clothing on the battery charger while charging bat-teries. Sparks could be induced, leading to fire.DDo not use voltage other than the specified power supply voltage. Fire or electri-cal shock could result.DDo not use batteries other than those designated. An explosion could occur, or abnormal heat generated, leading to fire.DDo not use damaged power cords, plugs or loose outlets. Fire or electric shock could result.EUse only the specified battery charger to recharge batteries. Other chargers may be of different voltage rating or polarity, causing sparking which could lead to fire or burns.DDo not use the battery or charger for any other equipment or purpose. Fire or burns caused by ignition could result.HDo not heat or throw batteries into fire. An explosion could occur, resulting in injury.ETo prevent shorting of the battery in storage, apply insulating tape or equivalent to the terminals. Otherwise shorting could occur, resulting in fire or burns.DDo not use batteries or the battery charger if wet. Resultant shorting could lead to fire or burns.DDo not connect or disconnect power supply plugs with wet hands. Electric shock could result.FDo not touch liquid leaking from batteries. Harmful chemicals could cause burns or blisters.DDo not use within the vicinity of hospitals. Malfunction of medical equipment could result.EUse the instrument at a distance of at least 22 cm from anyone with a cardiac pacemaker. Otherwise, the pacemaker may be adversely affected by the electro-magnetic waves produced and cease to operate as normal.DDo not use onboard aircraft. The aircraft instrumentation may malfunction as a result.DDo not use within the vicinity of automatic doors, fire alarms and other devices with automatic controls as the electromagnetic waves produced may adversely affect operation resulting in an accident.EXCEPTIONS FROM RESPONSIBILITYSTANDARD PACKAGE COMPONENTSOPTIONAL ACCESSORIESNOMENCLATURE AND FUNCTIONSName LED Function or statusPower switch Turns ON/OFF the power.Battery Low LED ON solidThe battery power is low.  Replace it withthe full-charged battery.Wireless LED ON solidThe wireless LAN function is valid.Flash Data are being sent/received.OFF The wireless LAN is not valid.System LED ON solidThis instrument (WT-100) is operatingnormally.Flash Flashes when the system executes anyprocessing.OFF This instrument does not operatenormally.Power LED ON solidThe power is ON.OFF The power is OFF.INSTALLING AND REPLACING THE BATTERYOperation panelDisplayConnector forProduct label:BatteryBattery coverPower switchBattery LOW LEDMountingexternal batterySerial numbercover lughole(Small)Mountinghole(car battery etc.)Antenna for wireless LAN           (DC12 V)Battery cover lugLugBT-66QContactBASIC OPERATIONSometimes an error message indicating the communication error with DHCP server is displayed on the product connected to WT-100.  In this case, net-work connection with WT-100 is normal.INITIALIZATIONSPECIFICATIONS
http://www.topcon.co.jpGLOBAL GATEWAY  http://global.topcon.com/Please see the attached address list or the following website for contact addresses.OthersOperating temperature range: -20°C - +50°CStoring temperature range: -30°C - +60°CWeight: 0.4kg (Including BT-66Q)Size:126mm (L) x 123mm (W) x 67mm (H) (When antenna is folded)Protecting against water and dust:IP54 (Based on the standard IEC60529)Battery BT-66Q (Li-ion)Output voltage: 7.4VCapacity: 2500mAhOperating time (+20°C): Approx. 8 hours or morezThe operating time of the battery is changed according to the ambient tem-perature and the operating status of the instrument.REGULATIONSRegion/CountryDirectives/ Regulations Labels/DeclarationsEUEMC-Class BEU R&TTE: Class 2R&TTE DirectiveWIRELESS TERMINAL WT-100Hereby, TOPCON CORP., declares that the above-mentioned equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.This equipment may be operated in CS, DA, DE, ET, EN, ES, EL, FR, IT, LV, LT, NL, MT, HU, PL, PT, SL, SK, FI, SV, IS, NO.France: Outdoor use limited to 10mW e.i.r.p. within the band 2454-2483.5MHz.Please inquire below if you wish to receive a copy of Topcon's Declaration of Conformity.Topcon Europe Positioning B.V.Essebaan 11, 2908 LJ Capelle a/d IJssel, The NetherlandsTel:+31-10-4585077 Fax:+31-10-2844949http://www.topcon-positioning.eu/index.aspEU WEEEDirectiveEU EU BatteryDirectiveU.S.A. FCCMeans of conformityThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:- Reorient or relocate the receiving antenna.- Increase the separation between the equipment and   receiver.- Connect the equipment into an outlet on a circuit different     from that to which the receiver is connected.- Consult the dealer or an experienced radio/TV technician for help.This equipment complies with FCC radiation exposure limits set forth for uncontrolled equipment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. To comply with RF exposure requirements for mobile configurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.WARNING:Change or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.Specified cables must be used for connection to external power supply in order to meet FCC emission limits.Model Number: WT-100Trade Name: TOPCON CORPORATIONManufacturerName: TOPCON CORPORATIONAddress: 75-1, Hasunuma-cho, Itabashi-ku, Tokyo, 174-8580 JAPANCountry: JAPANU.S.A. RepresentativeResponsible party: TOPCON POSITIONING SYSTEMS,INC.Address: 7400 National Drive Livermore, CA94551, U.S.ATelephone number:  925-245-8300California,U.S.A. Proposition65California,U.S.A.PerchlorateMaterial(CR LithiumBattery)Region/CountryDirectives/ Regulations Labels/DeclarationsCaliforniaand NY,U.S.A.RecyclingBatteries Canada RSSThis Class B digital apparatus meets all requirements of Canadian Interference-Causing Equipment Regulations.Cet appareil numérique de la Class B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.This class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.This device complies with Industry Canada license-exempt RSS Standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of this device.Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est authorisée aux deux conditions suivantes:(1) l’appareil ne doit pas produire de brouillage, et(2) l’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en conpromettre le fonctionnement.Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.Conformément a la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres utilisateurs, if faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire à l’établissement d’une communication satisfaisante.To comply with RF exposure requirements for mobile configurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.Une distance minimale de 20 cm entre l’antenne et toute personne doit être maintenue pour respecter les exigences à l’égard de l’expositions humaine aux radiofréquences. Ce dispositif ne doit pas être utilisé a proximité d’une autre antenne ou d’un autre émetteur.Region/CountryDirectives/ Regulations Labels/Declarations©2011 TOPCON CORPORATIONALL RIGHTS RESERVED22241 90060

Navigation menu