Toshiba T2E Brochure

2014-12-13

: Toshiba Toshiba-T2E-Brochure-130820 toshiba-t2e-brochure-130820 toshiba pdf

Open the PDF directly: View PDF PDF.
Page Count: 24

DownloadToshiba Toshiba-T2E-Brochure-  Toshiba-t2e-brochure
Open PDF In BrowserView PDF
	
	
	

TOSHIBA
PROGRAMMABLE CONTROLLER

PROSEC
r

At - ,

D_

-	

T2E / T2N

!4fte]- M,+„ Prcgn

Mr-1©

B°o-k

Etc
FIR 13

0100

This circuit controls
logic and R011 is the

MTR1 LOW
WIR1
HAM OIL
FAIL
PRESS
RDDDI

SHOD

r

1`

COOP
DEMO
MODE

0011 NO-02S

AL
MT R1
AUTO

O1fL IIf

4iew

15 .5

Advanced Features

,

• Floating-Point Math

,_ t y,

• Large Program

Data Memory

• EthernetlDevi eN t Networks
• Active Serial ASCII Port
• Two Programming Languages
• NIS

Programming Software

M

* M & F M. N

a
rt

.

#
AE

	

PROSEC T2E/T2N
Small, Powerful Modular Style
Programmable Controllers
Toshibaxs T EJT N are small, modular type programmable
controller suitable for both relay replacement and
complex control applications . The T EIT N are
2nd generation T2 CPUs . The T EIT N
provide a functional, economical, and
compact solution to a wide range
of OEM and user applications
in automotive, machine

T2N
Local l/O : Max . 2048 points
Program :

23 .5 k steps

Speed :

0.33 ps/contact

12 psltransfer

control, and process
control systems .

T 2E
Local I/O : Max. 1024 points

2

Pro-gram:

9 .5 k steps

Speed:

0 .33 ps/contact
1 .2 psltransfer

	
	

Key Features
High speed processing

Ethernet connection (72N)

The T2EIT2N excels at applications where high speed
processing is required .
• 0.33 ps/contact
• 0.44 ps'ooil
• 1 .2 Vs/1 B-bit transfer
* 1 .53 psf16-bit addition

The T2N CPU modules (PU235N and PU245N) have
built-in Ethernet interface (1 OBA E-T) . Through the
Et hemet, the T2N can communicate with higher level
controllers {computer, workstation, et-c-) or other
PLOs with Ethernet .

Advanced instruction set

High speed industrial LAN

The T2EJT2IN offers 24 basic relay-ladder instructions
and 192 function block instructions, including the
following .
• Arithmetic operation
• Data manipulations
• Trigonometric functions + P I D1ram pii ntegral
• Subroutine call
* For-Next loop
• Averagingr'filtering
• ASCII - Hex conversion
• Floating-point math

The T2E/T2N can be connected to Toshiba's high
speed industrial LANs {Local Area Networks)
TOSLINE-S20 and TOSLINE-F10 . The TOSLINE
series are suited for real-time control data linkage .
Through these networks, the T2E/T2N can exchange
data with other Toshiba equipment, such as the
TO DI CIE system, other T-series PLC , Large
Adjustable Speed Drives, General Purpose Inverters,
etc .
The T 2N CPU module PU 45N has the TOSUNES24LP (Loop version) built-in into the CPU module .
The TOSLINE-S20LP is a high-reliability double-loop
f iber -optic 520 network .

Two programming Languages
The T E!T2N supports two programming languages :
Ladder Diagram (LD) and Sequential Function Chart
(FC) . By selecting the appropriate language, or
combination of the two, program development time
can be greatly reduced .

Built-in clock/calendar
The T2EIT2N has a real -time-clockfcalender function
(year, month, day, week, hours, minutes, seconds)
that can be used for performing scheduled
operations, data gathering with time stamps, etc,

Device Net
A Device Net scanner module is available for the
T2ETT N . The CeviceNet scanner module can
readlwrite data to any other manufacturer's ODVA
certified devices (I/O blocks, Inverters to include
Toshiba's G3, air valve manifolds, sensors, etc .) .

Flexible serial port
Password protection
The T2EfT2N can be programmed with one of four
selectable protection levels_
+ Level 1 : No protect (normal)
+ Level 2 : Wi tirrglmoditying program prohibited
• Level 3 : Level 2 plus viewing program prohibited
+ Level 4 : Level 3 plus writing data prohibited
Battery-less operation (T2E)
The user-program is saved in a built-in Flash
memory . No battery maintenance is required .

The T2E1T2N has RS-232C or RS-485 serial
communication port . (It is optional in theT2E)
Using this port, one of the following communication
modes can be selected .
• Computer link mode : Connection with higher level
computer, MMI/SOADA system, modem, etc .
• Data link mode : Easy data linkage between two
T2Es, T2Ns, T2E-T2N or T2E1T2N Super T1 .
• Free ASCII mode: Active communication between
serial ASCII devices . {bar code readers . etc.)

Programmer port function
The T2EIF2N's RS-232C programmer port supports
the T-series computer link protocol . This allows easy
connection to a higher level computer, an operator
interface unit, a modern, etc .

3

	

System Configuration
T 2E CPU Unit Configuration

CPU module

Operation mode switch
Optional communication port
(Add-on option card,
AS-2320 or RS-486)

Rack

T2F_ basic components
[Iiarn
CPU -nodule

CPU add-on
option card

Power supply
module

; Type
_
I PU234E
M231 C
.. . CM232E
BT231 E
P S261

• The CM 31E and

1

Description
8 .5 k steps, clock/calendar
R- S -485 port, wwf battery
R9 232C port wl battery
Battery card
100 to 240 Vac
24 Vdc

[t13m

CPU rack

Expansion
rack

Type
BU218
UBB2
UBI31
_ UBA2
UBA1
RU26B
BU266

Description
8 110 sIcIs, expandable
7 l/O slots, expandable
_
4 110 S1O(S r Oxparldable
7110 slots . non expandable
4 110 slots, non expandable
8 I/O slots
6 I/O slots

the CM232E are optional communication cards for T2E. These cards also have the optional

battery mounted on them .
* The CM231 E has a terminal block for RS-485 interface . The CM 232E has a D-Sub 9-pin (female) connector for
RS-2320 interface_
* The BT231 E is a card that has only the optional battery_

• The T2E CPU module can hold only one option card :

M 31 E, CM232E or BT231 E .

• The UBA1 and the UBA2 are stand-alone CPU racks, expansion racks can not be connected .
• The UB81 and the UBB2 can be used as either CPU or expansion racks . When the UBB1 or UBB Is used as
expansion rack. only one expansion reek can be connected .
• The BU266 and the BU268 can be used as either GP U or expansion racks . When the BU266 is used as CPU
rack, it has 5 VO slots_ When the BU 66 is used as CPU rack, it has 7 1/0 slots_
4

	

T2N CPU Unit Configuration

Network status indicators (PLJ235N/PU245N)
CPU module

TO LINE-S20LP station No. switch (PU245N)

Power supply module

TOSLINE-S2OLP optic ;a! connectors (PU 45N)

Programmer port (RS-232C)
RS-232C/RS-485
communication port

Rack

I/O modules
10BASE-T Ethemet port {PU235N/PU245N)

T2N basic components
Item
CPU module

Type
PU215N
PU235N
RU245N

Dascription
23 .5 k steps, standard type,
Standard plus Ethernet _
Standard plus Ethernet
and TOSLINE-S2OLP

Item
Power supply
mfl-dule
CPU rack
Expansion
roc k

Type
P$251
P831
BU22ON

_

Descrfptlorr
100 to 240 Vac
24 Vdra 110 slots

BU268

6 11Q slots

BU266

6110 siot5

• The RS-232CIRS-485 communication port (D-Sub 15-pin female connector) is built-In the T2N CPU module.

The interface, RS-232C or RS-485, is selected by the switch provided on the CPU module_ This port has the
same function as the optional
mrnunicatlon cards (CM231 E or CM232E) on the T2E CPU,

• The PU235N has all the P1215N functions plus Ethernet (1 OBASE-T} interface .
• The PU245N has all the PU215N functlons plus Ethernet (10BASE-T} interface and the TOSLI[1E-S20LP
interface.
* Each T2 N1 CPU module comes with a battery-

• The T2N CPU module can be mounted only in the BU228N rack• The BU266 and the BU26B can be used on[ for the expansion racks with the T2N .

5

	
	
	

Expansion Configuration

In the maximum

Up to three expansiari racks (BU 266 or BU2SS) can be connected to the T2EIT2N CPU rack,
configuratior, the T2EIT2N provides 32 slots for 110 modules .

CPU unit

Expansi o n unit #1

Expansion unit #2

Expansion unit 43

• A power supply module is necessary in each rock .
• The following expansion cables are available ; SD cm, 50 cm, 70 cm and 1-5 m• The total cable length cannot exceed 4-5 fn-

Power Supply Check
The power supply module can output maximum 2 .5 A {5 Vdc) to power the internal logic of the modules. Check
that the internal current consumption of the modules on a rack is less than the 2 .5 A maximum .
The list below shows the internal current

consumption of each module .

Item

Type

Internal 5 Vdc
consumption

Item

Type

Internal 5 Vdc
consumption

T2 E CPU

PLJ234E

600 rn,4 or less

8 points relay output

R062

40 mA or less

T2E optional

CM231 E

200 mA or less

16 points transistor output

UO31

St} mA or less

communication card

Ch1232 E

200 mA or less

002331

60 mA or less

T2N CPU

PU215N

80O mA or less

32 points transistor output

0032

250 mA or less

PU236N

1 .5 A or less

64 points transistor output

D0235

250 mA or less .

PV245N

2 .0 A or Iris

12 pal nts true output _ _

AC61

300 mA or less

4 channels analog input

A121

50 mA -or less

CPU rack for T2F-

BU218

50 mA or less

USB2

50 mA or Less

A131

50 mA or less

USB1

5O rnA or Ir;ss

A122

50 mA or less -

UBA2

5f0 rnA or less

A132

50 rrA or loss

UBA1

50 'm\ or fens

A031

70 rr:A or less

CPU rack for T2N

BU228N

SID mA or less

A022

170 mA or less

Expansion rack

BU268

50 mA or less

I A032

170 mA or less

BU266

50 mA or less

1 channel pulse input

P121

80 rmA or less

16 points D input

1131

15 mA or less

1 axis positlon control

_. MCI 1

200 rnA or less

32 points DC input

D132

80 mA or less

Communication interface

C F211

550 mA or less

64 points OC input

D1235

100 ram or less

TOSLIMME -$2(coaxial)

5 N221

600 rnA or less

16 points AC input

IN51

15 mA or less

TOSLINJE-S20 roptical)

SN222A

700 mA or less

INN61

15 mA or less _

TOSLINE-F10 (master)

Map. 11

600 mA or loss

8061

50 MA or less

TOSLINE-F10 (route}

R821

600 mA or less

DN211

500 mA or less

12 pewits relay output

2 channels analog output

DeviceNet !~vanne6

	
	
	
	

Flexible Serial Port
Programmer Port
The T2EIT2N's RS-2320 programmer port supports the open T-series computer link protocol as well as the
proprietary programmer protocol . This provides an easy connection to a higher level computer, an operator
interface unit. a modem, etcInterface
transmission system

Master computer

I

PS-2320
Half-duplex

Tmansmisston speed

9600 bps

FramIng

Start bit :
1 bit
Data bits: B bits

Protocol

Parity :
Ood or none
Stop bit : 1 bit
Computer link protocol .
Programmer protoco!

T2 C{T2N

T2 EJT2 N

Communication Port on the CPU Module
The RS-232C or RS-4 85 mufti-purpose communication port is standard on the T2N CPU . The interface is
selected by a DIP switch,
The RS-232C or RS-4-85 muIti-purpose communication port Is an
option on the T2E CPU . A M231 E or
M232E card must be mounted ire the T2E CPU module .
By L, ir.g these communication port, one of the following three communication modes is available .

C omputer link mode
T-series computer Iink protocol can be used in this
mode . When the RS-485 is used, a maximum of 32
T2EfT2Ns can be connected to a master computer .
By using this mode, all the T2E(T2N's data can be
accessed by a master computerThe T-series PLO programming software (T-PDS)
can also be used in this configuration .

Master •:-.orrputer

*yst m
Transmission speed
Triongrnission

From ing

Half-duplex
30 0/ 8 0 00 2170124001
480019600JI9200 bps
Start bit : 1 hit
Data b,ls : 7 or B bits
Parity :
stop bit :

Protocol

Odd!evenlnone
1 or 2 bits

Computer link protocol .
Prograrnmer protocol

Master computer

LA
RS-4S5 (I km max .)

T2lrfT2N

T2 DT2 N

T2E'T2N

T2EIr2N
32 T2EJT2Ns max-

7

	
	
	

ommunication Port on the CPU Module
Free ASCII mode
be transmitted
and received through this port, A terrmirial, printer,
bar-code reader, or other serial ASCII device can be
directly connectedThis mode allows the T2E/T2N to communicate with
other PLCs (TI, T2E . T2N, etc), Inverters (such as
VF-S7/A5, G3), or Motor protection relays (S2E21) .
User defined ASCII messages can

Half-duplex

Trarsrnission system
Transmission code

ASCII

Transmission speed

30G/600{120tI/2410I
4800/9 0119200 bps

i Framing

Message €e gth

Start bit : 1 bit
Data bits . 7 or F bits
Parity,
Odd/even/none
Stop bit : 1 or 2 bits
512 bytes max .
Mote} RS-4 25 2-w-a system
a alto rrEUlablc,

RS-485 (1 km max .)

Bar-code reader,
Printer, etc-

.:T11

i
JI
Micro PLO T1
I

Inverter VF-$7
#,Actor Protecdori Relay
521521

Data link mode
Two PI-Cs (any combination of T2 E, T2 N1 or Super
T1-4D) oars be directly linked together . This direct
link is inexpensive, easily configured and requires no
special programmirtg- File registers F0000 to F0031
are used for the data transfer .

Transmission speed

10200 bpi

Protocol

Special
15 words (station 1 to 2)
16 words {station 2 to 1)
approx . 50 rrts
(not synchronized with
T2E/T2N's scan)

Link cata capacity
Link data update time

T2E Qr T2N

T2E or T2N

Station No .1
Station No-2
. .. . . .. ... ... .. ... ... ... ... .. ... ... ... . ... .. ... .. ... .. ... .. ... .. ... .. ... .. .. . ... .. ... ... ... ... ..
FOD00
F0000

F0015

8

. . ... ..... . . . . . . . . . . .

F0015

F0016

F0016

F0031

F0031

	
	
	

Networks
Network Configuration

Higher-level carnputerAvorkstatforn

-P . t

I

r
I :

0
11

T2N

ME"

TOSLINE-S20LP

ON
j2N
TOSLINE-S20

Any OIDVA

certified
d6vins
PlElime r,% cu-ont

OWN com for a
complete Avg of
inc: isiral dmicv* him

other manilaotures.
TMIllMRIC

I

Fia1c; In -Lellige,--a Station

HS

9

	
	
	

TOSLI NE-S241S2OLP
The TO LINE- 2O/ 2OLP is an N-to-N h€gh-speed data link ri(~twork . Implicit token passing avoids the

possibility of message collision, The TO LINE-820/ 2OLP Is idea! lo r real-time control between PL s, or
between PLCs and Toshiba Adjustable Speed Drives .

TOSLINE-S OLP

TOSLINE-S20

The TO LINE- 20 LIP is a high-reliability doubI9-loop

The TO LINE- 20 is a bus type data link f ?twork .

fiber optic system . The T2N CPU module (PLI245N)

The transmission media can be either co-axial or
fiber optic cable, according to the application
requirement .

has the TO LINE- 20LP built-in .
The double-loop configuration and the floating
master function allow the TO LINE- OLP to
continue data link operation even if a transmission
cable is cut or A station drops out of the network,

• 8 N2 1 : Co-axial cable type station for T2E/T

N

•

N222A : Fiber optic type station for T2EIT2N
These station modules can be mounted in any 110
slot, main or expansion rack, of a T2E(T2N system .

Item

TOSLINE-S2OLP

TOSLINE-520

Topology

Double loop

Bus

Access method

Implicit token passlric

Transmission speed

2 Mops

Transmission cable

Fiber optic cable (H-PCF 200/230 urn)

Coaxial cable (SC2V} or
Fiber optic cable (GI 50/125 um)

May . transmission distance

Fiber optic : 1 km (between stations)
System total_ 30 km

Max . n urnb-er of 5tetions Communication service
Scan transmission capacity
Scan data update tIme
Transmission error check
Parameter setting tool
Connectable device

I

Coaxial cable:
Fiber optic :
Systerr4 total :

1 km (cable total)

1 km (between stations)
10 km

64 ~;tationa
Scan transmission
Ms age transmission
1024 words
25 fns/1 024 words

4496 words
61 .4 ms/4096 words

CRC

I

TOSLINE 20/S2OLP Loader System (S-LS)
(software runs on Windows 95)
PLC (T3H and T2N),

PLO (T3H, T3, T2N, T2E and T2) .

Process control station (PCS),
Industrial computer

Pruc.ms control station {PCSI,
Industrial computer,
Plant drive (WS series),
inverter (VF-A5, fi3)

I

Remote Programming/mnanitoringthroughTOSLINE-$241$20 LP
TOSLINE- 20iS20LP

-A .I .1

00-

Noiet in lh e 7 J, the TQ6uNE-5zo Is souse by peas
and 1YRffE arslruct ns .

10

.1 .1.

:!1I1,11
.
Ii
1

	
	
	
	

The T2N CPU modules (PU2 5N and PU245N) have
a built-in Ethernet interlace (1 OBASE-T} .
Through Ethernet, the T2N can communicate with a
corn pu-er, a workstation, or another T2 N .
1 . T-series computer link protocol

E. : Computer/workstation
I '-

T21`41

Item
Interface
_
Media access mett •. ori
Modulation method
Topology
Transmission speed
Diistanv~l between rode
Segment length
Connector
Gable
Oommunicaslon service

2- T-series PLC link protocol
Send/receive

-

PLJ2UN I PU245N
U BASE-T
CS MA/CD
Base-band
Bus
1 D M bps
200 m mAx- (wiL#i 1 HUB)
17D0 in max . {with 4 HUBS}
100 m max . (Node to HUB)
E-p n modular (FiJ-45)
Twisted-pair (2B to 22 AVVG)
Computer link pratocal
T-series PLC link protocol
Socket i nterface (8 ports)

N,5W The E1 *enet xverfsca is controaai by T2N's SEND
End AECV' .^s'.n..ctions,

3 . Socket interface
Computertworkstation
I t

T2 N

..

DevIC,eNet.

DeviceNet is an open standard field network . Many
DeviceNet cornpatibie products (ODVA Certified} are
available from other manufacturesThe Dr1211 is a DeviceNet scanner module for the
T EIT2N . The DN211 can read/write data to any

other manufacturers OVDA certified devices,

such

as i/Q blocks, Inverters including Toshiba's G2, -air
valve manifolds, sensors, etc .

Item
j Topology
Number of slaves
Transmission speed
Media access method
Modulation method
Tdansniission distance_
(Trunk line)
Thick
Thin
Max. drop length
Max- total drop length
Scan 110 capacuy
Function

is acra4 ad by T2E1T2N's READ

Hotel Tho DN211
1}nd WRITE nstruotions .

Number of a N 211
on a T2E/T2N

IJN211
Bus
53 max .
125 k r 250 k. o• 500 k bps

CSMNNBA
Dase-band
125 k
2511 k
500 m 250M

100 m

100 m

1

1500 k
100 m

10D m

6m
Gm
6rn
156 m
78 m
39 rn
wards/204B
Input : 128
pts
Output : 126 word s/2048 pts
lasre parameter setting
from T2E{T2N
Bit strobe
• Polling
∎ Change of statelcyclic
Limited only by power capacity

11

	
	
	

TOSL I NE-F1 O
The TO L INE-F10 is afield network suitable for small distributed I/O systems- data link between T-series PLOs
is also available- The TO UNE-F1O is extremely easy to setup compared to other field networks.
For the T2EIT2N, two types of TO LINE-F10 station modules are available,
• M 211- Mast it statlort for T2ETT N
• R
11 , Remote station far T2E/12N
T#iese station modules can be mounted in any 1110 slot, main or expansion rack, of a T2EIT2N system .

bM

Item
Topology ---Accoss method

TO LINE-F10
Bus
Polinglsalectirro

Transmission speed
Transmission cable
Max . tmnsmissio^ distance

750 kbps or 250 kbps (selectable)
Twisted pair cable (1 .2 mm'}
750 kbps : 0 .5 km (total)
250 kbps : 1 km (total)
32 stations

Max . number of statianv,
Communication Service
_
Scan transmission capacity
Scan data update time
Trans r,iss'on errorchack
Connectable device

T2N (M5v211 :master)

T1-40

T1-40

Scan transmission
32 words
_
7 ns132 words (750 kbps)
12 rns132 words (250 kbps)
CRC
PLO MM/T3, T2N/T2E'T2 and T1),
Reir,ote 110 block,
Inverter {VF-A5, G3)

Not

Wneo VF-A5 :s court led,
at least on9 Ramota Input
Hock with lo-war .=tion
adsrosa mu51 he corjaoted,

T2 E
(R 211 : rennet$)
Inverter VF-A5

Remote I/O Block Specifications
hem
Module type
Input voltage
Min . ON voltage
Max . OFF voltage
input current
Input points
ON delay
OFF delay
Power voltage

12

1131633
DC input (Dry contact input}
24 Vdc, +10/-150b
96V
3-5 V
10 mA (at 24 Vdc)
16 points (1Wcommon)
10 ms or less
15 ms or less
24 Vdc, +1{U-15 96

Item
Module type
Output voltage
Load current
_
Output points
ON delay
OFF delay
Power voltage

R0563
D0633
Relay output
DC output
12 to 24 Vdc
24 Vdc, +-20%) !
240 Vac, --10% (max .)
+10}-20%
2 A/point {resistive}	
point,
4 Alcornmon
4 A1common
16 pm-nts (4 x 4/common) 16 points (16/comrnon)
110 ma or less
1 fns or less
._
1
rns
or
lass
10 ms or less
24 Vdc, .x141-15%

1

I

	

Programming Tools
T-series Compatible
The HP911 Handy Programmer and the T-PD (T-series Program Development System) software program the
entire family of T-series programmable contra€lera . Programming instructions are upward cerrtpatible in the
T-series controllers,

Handy Programmer
The HP911 is a hand-held graphic programmer . Its portability makes
it Ideal for maintenance use at remote locations . The HP91 1 has all
the features of a full size programming terminal_ (2 m cable for
connecting T2EJT2N is included)

• Ladder logic programming of T-series programmable controllers
T1, T2, T2E, T2N and T3 .
(E programmingfmonitoring is not possible)
• Built-in EEPROM allows program copy between T-series controllers .
• Two display modes,
Normal : 3 lines and 12 columns
Zoom :
Full device description
• Data monitor for VO and internal registers .
• On-line data set & IfO force .
• Backlit LC[) display for better operation in dim light_

Program Storage Module RM102
The R1vt102 is an external memory, which can store a T2E or a T2N
program, By using the RM102, program saving from the T2Eff2N to
the RM102, and program loading from the RM102 to the T2E/T2N can
be done without need of a programmer .
Because the RM102 has an EE PROM, mmaintenance-free program
storage and rapid saving/loading can be done .
Natu1 To connect the RM 10210 She T2 EIT2N, an ad#ipte+ Is 1sutuaa :ary,

13

	

	
	
	
	

P"

The

r

T-series

gram

Program

Development

Development

System

System

(T-PDS)

(T

is

a

PDS)

software

program

that

runs

on

any

Toshiba's

Notebook

computer or other IBM-PC compatible personal computer- The T-PDS software supports on-fine/off -line
programming, debugging and program documentation for all T-series programmable controllers ; T1, T2, T2E,
T2N,
The

•

T3

and

T-PDS

T3N-

software

has :

A full-feature program edition hart includes cut && paste,
search & replace, insert, delete, a#c .

•

Group

programming

Load r save

•

•

and

and

compare

block

merge .

programs

between

disk

file and CPU .

Monitor power-flow status of on-line ladder program
and register valuesSampling trace screen useful for system checking .

•
•

Disable inputs and force coils QN or OFF from keyboard .

•

Print map options such as register values, register/device

Document

programs

with

commentary .

usage . full crass-reference, etc-

•

Built-in Modem irli ;ialize and Dial-up .

lie,

w-

1_

x .1

xrr.,.b

r

! :, ;1,-1=;:_ m,

	•

v~lrwl 1Ma

I • ur,q
. ., 11 .5 I

l .,

1151®

Nzaa

~3 :'.: . : :.' : .J_w_- .

1415 w

,!

67171_ Fi+F+ ~+1° I , Fur 1551+11 I16lIF
_
. . ..L,~
{1'%
+1D 4F ~_.
IIF
GL

1.

h575 :
yJi1 IT
1l]]] •
F∎!x
.7714 . . .+ 1-~ . 1vy . IId{i
Fl .. . .I1
~7 . . . .y1.-,
111757
5131D

FF11{ IF1a5 INOI P021!

~51a5

I F 1t 7" - I k { }

57741

M7SF M756

10ri1

M11F7 •7 1# n#,ra

10!11 l

111715

Mill

144IJI 41717 CON

•7}!
....
I , . .-,
NIL

∎III7
-11--(J IiI
717 .7

•n

174

77x}1'I

x 75'7
T~RGq
	 .Y
1]I
..
xF AYYS
l .IY

Ih11F~ 171155571 mw Mill
I-i :

Fl

155

]

{HI

~r

-

x1Pl ,
!S
PNW *

HF!
x M
1011
Mia.

, 71'

x7717

1-,i

ILS1
L . .rMFS lam

r

.. .I F51 •} 1]

IIA

Fgrr]
i
rM 75747
w2 .,
., 77251
.1so.

Yu7} .
Lk •r

mot-if

1.-IJd27s
7l+i

flail,
' - ~ - <1IYF.F
1-y
FP71Y

r1 *L

1

iR:lP„1,1 f

h11i wm Pl

77]P'

F1Fn .
4.a

.-741

. .

}1

-

'fcii4

.>Y,++

.la14 ,7741-

F"_11.H

J

~ sLF IIdLi]

1171 !11 &

M

FIYIY

•+

;15
_1F

Iur .

. .

1 1P. .F#1F

Program execution monitor (Ladder)
Program edit screen

a YYr,I -'T,1

•x i< Lln• ,+ .

PA1
.b
.
911f Y~
9114 ~ '

7114

I
!!V r
#1# 4wn

1

II
hat"
" I
5417
2411
1FI
ls]
i+~ , 7 Ib . .dHFL'+NiF 11k MIFS]
7417
{'$ . •h l1
.857+
x1110 ' r •5 '1151]
n1_Ioo .
1555!
--1' 11+05455 ∎IF 11tH- - 51414
ADIO Fl

?F5F

),LL- .

L

S
	- i.

1

.751
D-

IMAMkkrr

I

F- . .

I

1s__

19:41111115 ∎Ilk, R19F F1

,L]1! 0 ,A1111]10jF*r 90p . pIT!! F1

Program execution monitor (SF C)

1 4

I

M115
11
MF15
MF11

1 1,1511

Sampling trace screen

	
	
	
	
	

Instruction Set
Basic Instructions
FUN No . ; Symbol

Arithmetic Operations
Name

FUN No . Symbol

Name

27

Addition

28

Subtraction

Transitional contact (rising edge)

29

Transition al contact (falling edge;

30

Multiplication
Division

-( )-I

Cole

31

D+

»~ -I

Forced coil (debugging purpose only)

32

D-

-III-

Inverter

33

-( I ) .1

Invert coil

34

D
_ of

-1

I-

NO contact

-1 / I-

NC contact

-III-III-

_

Double-word addition
Double-word subtraction
Double-word multiplication

-1 P1 - _ Positive pulse contact

35

tC

Double-word division
Addition with carry

-IN I-

Negative pulse contact

35

-C

Subtraction with carry

-( P)-t

Positive pulse coil

37

D+G

Double-word addition w !,h carry

-(N)-l

Negative pulse coil

38

D-C

JCS

Jump control set

39

U*

Double-word subtraction with carry
Unsigned multiplication

JCR

Jump control reset

40

U/

TON

ON delay timer

41

DIV

7OF

OFF delay timer

SS

Single-shot timer

44

Double-word increment

CNT

Counter

45

WCS

Master control set

Decrene-t
Double v --rd d¢ :re`na_rt

fi1CR

Master control reset

134

MCSn

Master control set (nesting)

135

tvlCRr

Master control reset (nesting)

148

TRG

Timer trigger

END

Increment

--

46

Logical Operations
FUN No. l Symbol
AND
48

End

49
50

DAND
OR

51

DOR

52

FOR

Data trar .sier

53

Double-word data transfer
Invert transfer

54

DEOR
ENR

Double-word invert transfer

57

Data transfer Instructions
FUN No . Symbol
18
MOV
	19
20

DMOV
NOT

_

Unsigned division
Unsigned double/single division

Name

SCCH G i Exchange
	 DXCH i Double-word exchange
TINZ
Table Initialize

55

DENR
TAND

- 58

TOR

59

TMOV

Table block transfer

- .60
64

TNOT
MPX

Table invert transfer

65

Multiplexer

66

DPX

Demultipiexer

92

T8M

Table -a loft t ran sfer

93

9TM

Bit -- table transfer

TEOR
TENR
TEST
DTST
TEST

Name
AND
Double-word AND
OR
R
Double-word OR
Exclusive OR
iDouble-word exclusive OR
NOT exclusive OR
Double-word NOT exclusive OR
Table AND
Table OR
Table exclusive OR
Table NOT ex clusive OR
Bit test
Double-word bit test

_

Bit file bit test

Shift Instructions
Name
FUN No . Symbol,
SHRi
1 bit shift right
68
69

SHL1

1 bit shift lef;

70

SHRn

n bits shift right

71
72

SHLn
TSHR

n bits shift i5ft

73
74

TSHL
SR

75
76

j DSR

I

SFT

bit file n bits shift r ight
Bit file n bits shift left
Shift register
Bi-directional sniff register
Device shift

15

	
	
	
	
	
	
	
	
	
	
	
	
	
	

Rotate Instructions
FUN No- Symbol
78
RTR1
79
RTL1
RTFtn
60
81
RTL .rs
82
TRTR
TRTL _
83
84
RR C1
85
RLC1
RRCn
86
87
HLOn -s8
I TF RC I
TALC I
99

Name
1 bit rotate right
1 bit rotate left
n bits rotate right
n bits rotate left
Bit Me n bits rotate right
Bit the n bits rotate left
1 bit rotate right with carry
I bit rotate left with carry
n bits rotate Tight %vith ca-'y
n b -st5 rotate left with carry _
B ;1 flee n bits rotate right with carry

97
98
100
101
1112

. .
<
<=
DL

108

U>

109

L1L=

106

110
ill
112
113

L

1 R

107

104
105

U=
, U<>
j U<
I U<=

I

Name
Bit file comparison
Greater than
Greater than or equal
Equal
Not equal
Lass than
Less than) or equEd
OouVie-word greater than
Double-word greater than or equal
Double-ward equal
Double-word not equal
Double-word less than
Double-word less than or equal
Unsigned greater than
Unsigned greater than or equal
Unsigned equal
Unsigned not equal
Unsigned less than
Unsigned less than or equal

Special Data Operations
FUN No- Symbol
Name
L vice / register eat
114
SET
115
RST
Device I register reset
1 1 fi ° TSET
Tab ;e bit set
i
Table bit reset
117
TRST
118
SETC 1 Set carry
119 I RSTC I Reset carry

16

ENC . .120
121,_ DEC
12
SO
123
124
125
- 126
1-27
147
149

DBC
SC H
PUS H

Name
Encode
Dec ocle
Bit count
double-word bit count
Data search
Push

POPL I Pop last
POPF
Pop first
FIF
Flip lop
_
UJD
Up / down counter

Program Control Instructions

F;;__

10->D- _
D<>
D<
D<=

103

FUN No- Symbol

Bit file n bits rotate left wizh carry

Comparison Instructions
FUN No, . Symbol
95
TGMP
9s
I

Special Data Operations

FUN No_
128
137
125
130 .
136
132
133
138
_ . .140

Symbol
CALL
S1JB R
RET
JUMP
LBL
FOR
NEXT
STOP
El

141

DI

142
143
144
145
146
158

IRET
WDT
S1iZ

158

241

_

3T1M

Name
Subroutine call
Subroutine entry
Subroutine return
Conditional jump
Jump label
FOR-NEXT loop (FOR)
FOR-N1EXT loop (NEB
Program execution stop
~ Enable intem+pt
I Disable Intenxupt
interrupt return
_
Watchdog timer reset
Step sequence initialization
i $tap sequence input

TOT i Step sequence output
DRUM Drurn sequenoer
GAM
Cam sequencer
SFIZ
5F initialization

RAS Functions
FUN No, j Symbol
150
IDIAG
DIAR
151
152
153
154
155

STLS
STLR

Name
Diagnostic display
Diagnostic display reset

Status latch set
~ Status latch Tesot
Calendar set
CLIP
OLIDS
Calendar operation

	
	
	
	
	
	
	
	
	
	
	
	

BCD Operations

Functions
Name

FUN No .' Symbol

I FUN No, j symbol
192 1 B+

I
I

Name
BCD addition

56

MAVE

Moving average

61

[)FL

Digital filter

193

1 B-

160

UL

Upper limit

194

BCD muttillkcation

161
162

LL

Lower limit

1966

B*
$/

MAX

196

D5+

pquble-word BCD additions

197

Double-word 80D subtraotFan

198

DBDB*

199

DBl

163

MIN

maximum value
Minimum value

154
165

AVE_

Average value

rG

Function generator

166

136

Dead Land

157
168

AT

Square root

169

FLAMP

170

PlO

PID (proporaiona1 integral derivative)

171

PID2

Deviation square PID

156

PID3

Pre-derivative real PID

172

SEIN

Sine function

173

GOS

Cosine function

174

TAN

Tangent function

175
176

ASIN

Arc-sine function

ACOS

Arc-cosine function

177

; ATAN

Are-tan giant lunctiim

L17S

EX P

Exponent ai function

179

LOG

INTG

_

I Integral
Ramp function

Loga • . thm

-

Data Conversion Instructions
FUN No . . Symbol

Name

BCD subtraction
BCD division

Double-word BCD muItipticMion
Double-word BCD division

Bt

, BCD addition with carry

201

B-C

, BCD subtraction with carry

202
203

DB+G Double-word BCD addition with carry
DB-C
Double-word BCD subtraction with

00

carry

Floating-Point Lnstructions
FUN No . Symbol
204
FLT

1
1

Name
Fixed-point to floatlng-point
conversion
Floating-paint to hxeb-poiri
conversion

205

FIX

208

F+

Fkoatirrg-poi*1 addition

209

F-

210

F*

Floating-point subtraction
Floating-point multiplication

211

F/

Floating-point division

212

F>

213

F>=

Floating-point greater than
Floating-point greater than or equal

21

F=

HTOA

HEX to ASCII conversion

215

F< >

53
180

, ATOH

ASCII io HEX conversion

216

F<

Floating-point not equal
Floating-point less than

F .-

Floating-poicrz less than or equal

DABS

Absolute value
Double-word absolute value

217

181
182

KEGS

183
184

DNEG Double-word two's complement
Double-ward corwe{sion . .
DW

185

7SEC

62

186
188

AB

1 ASC
j -- BIN

~- 1139 -- DBEN

190
191

BCD

E)RCD

; Floating-point eqlel

! Two's complement

7-segment d$ccde
ASCII conversion
BCD to binary conversion
Double-word BCD to binary conversion
Binary to BCD conversion
Double-word binary to BCD conversion

Special I/O Instructions
I FUN Na-i Symbol ~- . ..
235
239

- .257
235
239
240

Ilk
XFER

Name .

Direct Input 1 output
[ Expanded data transfer

READ
'oVR17F

Special module data read

SEND

Network data send
Network data roca .we

RECV

Special module data write

17

	
	
	
	
	

Specifications
Functional pecificaitions
[tam
Control meihad
Scanning system

T2 E_
T2N
Stored program, cyclic scan system
Floating scan or constant scan (Interval ; 10 to 200 ms, 10 ms units)
I/'O processing method
Batch I!0 (refresh), Direct I/O, or combination
Number of 110 points (local)
1024 points/64 w ords
2D4$ points/128 words
s --- Program language
Ladder diagram (relay symbol + function block)
program
Soquentai Function Chart (SFC)
Program capacity _
9-5 k steps
S Ic steps 1
Memgry
SRAM arid Flash memory
Instructions
, Basic ladder instructions ; 24 types
Function instructions: 192 types
Execakion speed
0 .33 pslcontaot, 0 .44 uslcoil, 1-2 psArartsfer, 1-G3 psladditian
Program types
1 main program
1 Sub-program (il
it ;al program)
1 timer interrupt (interval : 5 to 1000 rns_ 5 ins units)
256 subro irses
User
I/O device/register
1024 points/64 words
2046 points/1 28 words
data
(XIY or XWIYW_ batch 110,
(V Y or XWNW. batch I/O .
110 or EW/O : direct I/O)
I/O or IWIOW : direct Il0)
Auxiliary devicelregister [ 2048 p oints/1 28 words (R!IlW)
4090 pointsJ256 words (P/RW)
Special device/register
4096 pointsl256 wards (S/S ^
./7) M00-7163: 10 ins}
Timer device/register
256 points (r
512 points (T,r, (T000-T063 : 10 ms)
(T0E4-T255: 101 ms)
(T06J-T511 : 100 ins)
Counter device/register
256 points (C,1C)
512 points (O .!O)
. Data rogistsr
4096 words (D)
9192 words (D)
Link de :ricelregister
8192 pointsll024 words (Z/tN)
16000 points, 0t8 words (ZAW)
((orTOSLINE-S20)
(for TOSLINE-S2OLP)
Link relay/register
4096 pointsl256 words (IIJL) (forTOSLINE-F10)
File register
1024 words (F)
Expanded file register
24576 w r s (access cl by XFER irl5truction)
Index register
I, J, K (total 3 words)
Re tentive memory
User specified range for RW, T, and D, end whgl$ F
Olacklcalen d ar
Year, month, day, day of the week, hour, minute, second
SRAM memory back-uo
u per capacitor : 3 days/25 'C
Battery {built-in, : 5 years) 5 °C
Battery (option) : 5 years/25 ° O
Serial communication function
Programmer port:(RS-2320) ; + T-series programmer protocol (1-to-1)
• T- series computer link protocol (1-to-1)
Communication port :
• T-series programmer protoco' (1-to-N)
(RS .-485 or RS-2320)
• T-series computer link protocol (1 -to-N)
(using optional rornms card
• Free ASCII communication
in case of T2E)
• 92 words data .link (between two T2E1T2Ns)
Networks
TOSLINE-520
Ethernet (10 BASE-T)
TOSLINE-F1 D
TOSLINE-S20LP
DeviceNet
TOSUNE-S20
TOSLKJE-F10
DevicaNe
RAS
' Diagnosis
Battery level, i/O bus check . I/O reaponse, 110 registration . Il0 parity,
watchdog timer, illegal insttuctron . LP check, others
Monitoring
Event history record, scan timr; mnasuroment, other
DebLlgging
On-line trace monitor, force, sampling trace, status latch,
single steplrung execution, weak point setting, others

18

	
	
	
	

General Specifications

I

Item
Power supply voltage
Power consu m ption

Specitlcatiin
100 to 240 Vac (+10(15 9A), 50160 Hz
24 Vdc (+201 .15 °r4)
53 VA or !ass (ac power supply)
22 4V or less (dc power supply)
10 mo or loss

RefentIve power interruption
Insulation. resistance
Wi_hstand voltage _
Ambient temperature

10 i1IQ or more (between power terminals and ground terminal)
500 Vac - 1 minutes (between power terminals and ground terminal)
0 to 55 - G (operation)
-20 to 75 °C (storage)
I 20 to 90 v lo
(no condensation)
-i'006 V p-r11 is, 99/336/EEC (EMC directive)
16 .7 Hz - 3 mm p-p (3 mutually perpendicular axes)
98 m/s' (10 g) (3 shocks per axis, 3 mutually perpendicular axes)
U L /c-UL., CE

Ambient humidity
Noise immunity
Vibration immunity
shock 3rnrr n ity
Standard -

External Dimensions

4-05

a
FT

i

t

F
i

Y

3-

106 .5
VV3

d

115 .0

V V2

	i
3 1
W2
W1

13U228ht
366-0
380 .0
394 .O

BU218
366 .0
380 .0
394-0

168 .0 (

F

BU268
300 .0
314-0
346-0

r

143 .0 (terminal}

w

VV1

-U

w

BU265	UBB2
234 .0
000-0
248 .0
314 .0
274,0
328.0

y

I

nnector)
w

UBB1	UBA2
201 .0
300 .0
215,0
814€ 0
229 .0
828 .4

UBA1
201,0
215-0
229 .0
Ur1_ mm

19

	
	

110 Module Specifications
Digital Input
Item

D161

D132
DG input, current sink so

Module type
Input voltage
-- 12 to 24 Vdclac, +101-15%
Min ON vortage
96 V
Max . OFF voltage
3.6 V
Input current
8 mA (at 24 Vdc)
Input points
- 16 points
(16/common)
ON delay
10 rns or less (dc mode N)
1-5 ms or less (dc. made H)
OFF delay

24 Vdc, +1 W-15%
16-0
V
$ .L7 V

16-0 V
6,01
5 MA {at 24 Vdc)
32 points

4 rrtA (at 24 Vdc)
64 points
{S x 8ICm}mrnon)

(4 x 8l common)
10 ms or less (mode N)
1-5 ms or less (moth H}

10 ms or less (dc, mode N)
1-5 ms or less (dc, mode H)

Item
Modula type

DI235

10 ms or toss
ms Qr less

10 ms or less (mode N)
1 .5 ms ar less (mode H)

1_:
IN61

IN51
AD input
100 to 120 Vac, +10115% (50160 H4

input voltage
Min. ON voltage
Max . OFF voltage

80 Vac
30 Vac
7 mA (at 100 Vac)

Input current
Input points
ON delay
OFF ds1ay

200 to 240 Vac, +10115% (50160 Hz)
160 Vac
~60 Vac
_ 6 mA (at 200 Vac)
16 points (16fcomrnon)
20 ms or less
15 ms -or less

Digital Output
Item
l Module type

1

ON delay
OFF delay
Leakage current

DO-32
DC output, currant

I

16 points
(161common)
1 ms or less

32 points
(4 x 8/common)
1 ms or less

I ms or less

2 rr's Cr l g

!

I

5 to 24 Vdc, ±10%
13 .1 A point (12/24 V)
0 .05 Alpoint (5 V)
64 points
t8 x 81common)
1 ms or less
1 ms or less

current source
12 to 24 Vdc -10% 1 Alpoint {12/24 V}
1,2 Af4 points
16 points
(161comman)
1 ms or less
1 rns or less

0 .1 rnA or less (at 21 Vdc)

Item
Module type
Output voltage

R061
8052
Relay coniactoutput, normally open contact
24 Vdc, +20% / 240 Vac, x .10% (Max-)

Load currant

2 Afpoint (resistive load)
_
4 /common
12 points (3 x 4lcommo-i)
{0 nis or
15 ms or

Output paints
ON delay
OFF dewy
Leakage current

D0233P
DC output,

D D235

sink

5 to 24 Vdc, +10f-5%
I Alpoint (12124 V)
0,1 Alpoint (12124 V)
0,3 Alpaint (5 )4
0 .02 Arpoint (5 V)
1 .2 A14 points

Output voltage
Load current

Output points

D031

21VpoInt {resistive load)
6 points ({solated)
Less
Iass

None

AC-61
AC output
100 to 240 Vac, +10115%
(501613 Hz)
0.5 Afpoint
_16 AV_S_SR (2 points)
12 points (3 x 4/common}
1 ms or less
1/2 cycle . I ms or lees
1-2 mA er less (at 100 Vac)
3 mA or less (at 240 Vacs

20

	
	

Analog Input
Item
Input range
Input impedance

A121
1to5VI4to20mA
1 to 5 +1 . 500 ku
or more
4 to 20 mA : 250 57

A151

A122

A132

1to5V/4to20rnA
-10to10V
1 to 5 V : 1 M
1 Mn or more
or more
4 to 20 mA : 250 Q
4 channels (4/common)
a-bit (0 to 250)
12-bit (0 to 4000)
12-bit (-2000 to 2000)
Approx . 1 rnsl4 channels
Approx . 9-6 msf4 channels
t1 % (full scale)
±[I .5 % (full F'calo)

input ahanneis
pesulution
Conversion cycle
Overall accuracy

Oto10V
500'c 2 ar more

Analog Output
Item
Output range

-

Load impedance

Output channels
Resolution
Conversion cycle
Overall accuracy

_ A031
1 to 5Vf4to20mAf
0to5Vf0to10V
5 V range : 5 kO or more
10 V range; 10 kfz or more
20 mA range: 600 Q or less
8-bit (0 to 250)
f1 % ( full scale)

Pulse Input
Item
Input channels
Input voltage
Input current
Counting speed
Count data
Pulse input mode

Message length

A032
-10to1OV

1 to 5 V, 5 kQ or more
4 to 20 rnA. @00 or less

5 kQ or more

2 channels (2/common)
12-bit (0 to 4000)
I
12-bit (-2000 to 2000)
Approx . 1 rns12 channels
#0 .5 % (full scale)
Position

T P121
1 channel (phase A- B, and M
5112 V, +10%/-209
10 nA (5 V)
7 .5rnA(12V)
100 k pps max24-bit binary
(8368608 to 8368607)
Quuadrature (90 ° phase sift),
Up/down (A : up I B= down)

Communication Interface
1terrr
Interface
Transmission
system
Transmission
I code
Transmission
speed
Framing

i

A022
1 to 5 V f 4 to 20 mA

GF211
RS-2320, 1 pork
Full-duplex

Control

Item
Control axes
Control units
Control range
Pulse output
Speed
Input signals
Input voltage
Pulse output
Output vo)taga
Parameters
Parameter
.backup

MC11
1 axis
PLISe, mm, inch, degree, etc,
1999,099 (specifled unit)
200 k pps max .
Zero-marker, over-travel limit,
emergency stop, etc.
12 124 Vdc (10 mA)
CW and CCW,
Pulse arrd Direction
5 to 24 Vdc (,50 MA)
Acceleration/deceleration rate,
backlash compensa-t'ron, atcEEPROM

ASCII
300, 500, 1200, 2400, 4800, 96€ 0, or 19200 bps
Start bit ; I bit
data bits : T or S bits
Parity :
Odd, even, or none
Stop bit. 1 or 2 bits
320 bytes max21

	
	
	
	

Ordering Information
Item

~_L.

T2E CPU module

T2ECPU add-on
option card

Description

.

Type
PLJ 34E

9 .5 k steps, flash memory, clocklcaleridar
Communication card RS-486, with battery

CM231 E
CM232E
BT231 E
PU215N

ommunication card R5-232C, with battery
Battery cord, oath battery
T2N CPU module ; Standard type, 2a,5 k steps, flash memory . clock/calendar,

CPU rack

RS-232C/RS-485 communication port, with battery
Standard type plus Ethernet and TOSLINE-S20LP
For T2E
Non expandable

Standard type plus Ethernet

Expsndable

Expansion rack

For 72N
6 I/O slots

Expandable

4
Il0 slots
7 110 slots
4 110 slots
7110 slots
8 110 slots
8 110 slots

I/O module

100 to 240 Vac
24 . Vdc
10 points, 12 to 24 Vdclac, 8 MA
DC input
32 points, 24 Vdc . 5 mA (connector typia)
64 points, 24 Vdc, 4 mA (connector type)
16 points . 100 to 120 Vac, 7 mA
AC input
1 B paints, 200 to 240 Vac, 6 mA
ReI y output
12 points, 24 Vdci2401Tac, 2 Alpoint
6 points "isolated) . 24 Vdc1240 Vac, 2 Appoint
-DC output
16 points, 5 to 24 Vdc, 1 A/point
32 points, 5 to 24 Vdc, 0-1 Apaint (connector
64 points, 5 to 24 Vda, 0:1 Appoint (cor1necko
16 pts, 12 to 24 Vdc Y )iipoint, current source
AC output
12 points, 100 to 240 Vac, 0-5 A/point
1 to 5 V/4 to 20 mA, 8-bIt resolution
Analloj Input
0 to 10 V, 8-EbIt resolution

1 to 5 V24 to 20 mA, 12-Lit resolution
-10 to 1 a V, 12-bit resolution
1 to 5 Vl4 to 20 mNO to 10 V, B- bit resolution
I to 5 VJ4 to 20 mA, 12-hit resolutions
-10 to 10 V, 12-bit resolution
1 channel pulse input, 5/12 V, 100 is pps max .
I axis os;tio + Control, pulse train, output, 200 k pps rnax .
Communication interface . RS-2320, 1 port
TOSLINE-S20 Cc-axia! Cable typo station for T2&'T2N
Fiber optic type station for T2E{T2N
TOSLINE-F1O Master station for T2E/T2N
Remote station for T2E/T2N
Remote input block, 16 points, 24 Vdc
Analog output

Network

Remote output block, 16 points, relay
Remote output block, 16 points . 24 Vdc

DeviceNet scanner module for T2E,T2N

22

.

I

TC M232EAS
TBT231 EAS
TPU2I 5N •S

PU23SN
P1J245N . .

TPU235N •S
TPU245 NI+S

UBA1

EX10*UBA1

I JBA2
Uf3B2

E{1 a~USA2
EX10-U B B1
E X10-U13131

BU218

TEU218-S

BU228N -

TBU228N+S

BU266

TBU266zES TBU2688}S TPS261 * .S
EX10*W P531 .
EX10*MDI31

UEB1

SU265

S 110 slots
Power supply

Part number

TP0234E+5
TO M23 1 EAS

P5261
PS31
C 0131
0132

_ 01235

iNfS1

IN61

EX10*MD132

TD1235 •+ S
EX10*MIN5i -

- EX0 MII N61

8061
R062

EX1O •M R061
1 X10*M€ 062

D031

EX10 •M 0031

DO 32
D0235
D0233P
A 6

EX10*MD 2
7D0~35+*
700233PEX10 •M AC61T

A121

EX10 •M A121

A131

EX10-MA1 1

AI22

EX10 •M A122

A132
A031
A022
A032
P121
MC11
CF211
SN221
SN222A
MS211
RS211
01633

EX10*MAE32
EX10-MAD31
EX10*MA022
EX10•M A032
EX1 OW Pikk
Ex1L*MMC11
TCF211 •* S

80663

FRO663*K

00633

FD0633•1
TDN211 •* S

DN21 1

55N2.21 iM5
S5N222AMS
FIMS211AM
FR5211AM
F0FE33 •K

	
	
	
	

Item
Expansion cable

Rvscripiion
0 .3 m length
0 .5 rn Ierr~Ei
0 .7 m length
1-5 m Icngth
PrograrnmIng software
For MS-DOS
(T-PDS)
For Wiidows 3,1/95
bandy programmer with 2 m cable forT2ErT2N
Configuration softvraro for
For MS-DOS r S20 Manly}
TOSLINE-S20/ 20LP (S-LS)
For Windows 95 (S20/ 20LP)
Progra m storage module -5 m table for t-PGS or S- LS
Empty slot cover
R S- 232Cl.RS .-185 converter
Spare battery

Peripheral too]

P eripheraI cable
!Miscellaneous

Type
CARS
CARS
CART

Part number
EX10*CAR3
.E

tO-CARS

E X1 o*CAR7
TCS2RFTMt033f1ss . . -

CS2RF
T PD
T-PDS Win ' TMW33E15S

HP911
S_
S-L Win
RM102
CJ905

THP911 -S
SMM231 •S
' SMW23EtGS
TRM102-S
TCJ955-CS

EX 10-Af3P1
ADP-623 78 EX25FAf)P
-

,37E

E 25SER6

Quality
Quality is a religion at Toshiba, Quality starts at the very basic level, the J (integrated circuit), and proceeds
through design development and manufacturing of all types consumer and industrial piodircts .

r~n.~. r~R Ir
hvMX

~lY 1-24
i3' ~ Ms cw
J

nhi.

.iw1

rkWsw rrh-xia
% M~IAw'r~Yi.vyrsn

rw`r
J.
.4a~rrr.l
+rr~4i~ ~i~rl~Ywfd7s :{yarr
'+w .'f ~.r Mh"~IY nfFIwx.~r1A~V1~~

,

Ls

.•4

•--.r

nr..'

Toshiba corporation's quality management system in
design, development and manufacturing of
programmable cantroirers is approved to satisfy A he
quality management standard 1509001 .

23

	
	
	
	

A

Safety Precaution

T Is product le intended to be used for the central of Industrlal
machines and prncensen.
Mlsueo *f this pi-oduct Can reeu!t In property derrrage or human Injury.
Rood re1atad manumIe carefully before using IRIS product.

PRCS'EC and TOSUNE are registered trademarks of TOSHIBA Corporalion .
IBM i~ ea rE$igttrr$JJ keado'r0u 1 pl International 8uslness Machines CarparetIon.
M$-k7Q$ and Windows are registered trademarks of Microsoft Corporation
.
Elhernet e registered trademark of Xerox Coopcsaiaon,
DwerriC-N t i .a irvlernark pi the Open deviaeNet mender Aseacletion, Inc .

s

For further information, Rlease ccwtact your riearerlri Toshiba
International Operations-Prod,icerisoods .

Represer talrve or

Tho data yliwen in this brochure are EubjecII to Change WitRiOUt notice-

In Touch with Tomorrow

TOSHIBA

TOORDA It1w"41hphN
Corporation
Industrial Division
HOUSkCr'U.S .a .
Tial . :71 3-4G6-0277
Fax- : 713- i -97 73

Yeeh1hp lnternatlonal
Tirsblbe I ntemetlonel
Corporation (Europel Lid . Corporoion Pty., Ltd .
MiaIIec-x U .K
Syd - xx AuGir)Ib
Tel . : 13101 •75b-6CC.7
"+ol .
Fax . : 01$1-r 4 -4 R
Fex . : D2-c2'-7j-.C&0

Toshiba Aele Peclfic
Pte, Lt0
.
~~ IIlga we

Te . : Fn -321-13 .2S
Fax . : 65-324 . 2f

TOSHIBA CORPORATION
Ir dustrtal Equipment Department
Mirra1G-4A1, Tekyo1O5, Japan
Tel-_ (3)3457-49
Fax ; (3)3444-92[36

97-11 {K f 6527

Primed in Japan



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.0
Linearized                      : No
Create Date                     : 2002:12:12 12:12:59Z
Creator                         : OmniPage 12 http://www.scansoft.com
Producer                        : OmniPage 12 http://www.scansoft.com
Page Count                      : 24
EXIF Metadata provided by EXIF.tools

Navigation menu