Split System Heat Pump Product & Performance Data XB 13 2TWB3018-060 1½ – 5 Tons PUB. NO. 22-1771-04 Features and Benefits • Climatuff® compressor • Demand Defrost Control • All aluminum Spine Fin™ coil • Easy top & fan removal • DuraTuff™ base, fast complete drain, weather proof • R-22 refrigerant (Not Factory Supplied) • Polyslate gray cabinet high gloss with fan motor cover • Low ambient cooling to 55°F as shipped • Quick-Sess™ cabinet, easy service access and refrigerant connections with full coil protection • Low ambient cooling to 40°F with EDC accessory AY28X084 • Corrosion resistant finish and fasteners • Internal high/low pressure and temperature protection • Liquid line filter-drier • 100% line run test • Low ambient cooling to 30°F with EDC accessory AY28X084 and TXV • Extended warranties available • Easy single side service • Compressor sump heat all models © 2011 Trane 2 22-1771-04 Contents Features and Benefits 2 General Data 4 Product Specifications A-weighted Sound Power Level [dB(A)] Accessory Description and Usage AHRI Standard Capacity Rating Conditions Model Nomenclature 6 Electrical Data 7 Dimensions 9 Mechanical Specification Options 22-1771-04 4 4 5 5 3 10 General Data Product Specifications Model No. 1 2TWB3018A1 Electrical Data V/Ph/Hz 2 200/230/1/60 Min Cir Ampacity 8 Max Fuse Size (Amps) 15 Compressor CLIMATUFF ® RL Amps - LR Amps 5.9 - 38.6 Outdoor Fan FL Amps 0.6 Fan HP 1/15 Fan Dia (inches) 19.0 Coil Spine Fin™ Refrigerant R-22 (Not Factory Supplied) 5/10-LB/OZ 5/8 Line Size - (in.) O.D. Gas 3 1/4 Line Size - (in.) O.D. Liquid 3 Dimensions H x W x D (Crated) 37.2 x 26.7 x 30 Weight - Shipping 202 Weight - Net 182 Start Components YES Sound Enclosure NO Compressor Sump Heat YES Optional Accessories: 4 Anti-short Cycle Timer TAYASCT501A Evaporator Defrost Control A/C AY28X084 Rubber Isolator Kit BAYISLT101 Snow Leg-Base & Cap 4" High BAYLEGS002 Snow Leg-4" Extension BAYLEGS003 Extreme Condition Mounting KitBAYECMT023 Refrigerant Lineset 5 TAYREFLN1* 2TWB3024A1 200/230/1/60 12 20 CLIMATUFF® 8.7 - 57.8 1.3 1/4 19.0 Spine Fin™ 5/11-LB/OZ 3/4 5/16 37.2 x 26.7 x 30 205 184 YES NO YES 2TWB3030A1 200/230/1/60 13 20 CLIMATUFF® 9.5 - 63 0.9 1/8 23.0 Spine Fin™ 6/07-LB/OZ 3/4 5/16 42 x 30.1 x 33 240 212 YES NO YES 2TWB3036A1 200/230/1/60 19 30 CLIMATUFF® 14.1 - 90.8 1.4 1/6 27.6 Spine Fin™ 7/06-LB/OZ 7/8 3/8 42.4 x 35.1 x 38.7 291 256 YES YES YES TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT023 TAYREFLN2* TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT023 TAYREFLN2* TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT004 TAYREFLN3* 1 Certified in accordance with the Air-Source Unitary Heat Pump equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Use only HACR circuit breakers or fuses. 3 Standard line lengths - 60', Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. A-weighted Sound Power Level [dB(A)] SOUND POWER LEVEL [dB(A)] 63 2TWB3018A1 74 43.5 52.1 57.0 65.5 67.3 66.8 62.1 55.4 2TWB3024A1 79 51.3 56.1 61.7 71.5 73.1 71.8 64.3 55.8 2TWB3030A1 79 43.8 58.8 62.2 69.2 72.1 71.4 62.5 56.8 2TWB3036A1 79 47.1 60.4 67.8 73.5 73.7 71.6 63.8 51.4 2TWB3042A1 80 48.6 59.9 66.9 73.0 75.2 70.3 64.4 55.2 2TWB3048A1 78 45.4 58.8 66.1 72.5 72.5 69.8 63.0 52.5 2TWB3060A1 79 46.7 55.2 66.5 73.5 73.8 71.8 65.8 56.7 MODEL A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] 125 250 500 1000 2000 4000 8000 Note: Tested in accordance with AHRI Standard 270.95. (Not listed with AHRI) 4 22-1771-04 General Data Product Specifications Model No. 1 Electrical Data V/Ph/Hz 2 Min Cir Ampacity Max Fuse Size (Amps) Compressor RL Amps - LR Amps Outdoor Fan FL Amps Fan HP Fan Dia (inches) Coil Refrigerant R-22 (Not Factory Supplied) Line Size - (in.) O.D. Gas 3 Line Size - (in.) O.D. Liquid 3 Dimensions H x W x D (Crated) Weight - Shipping Weight - Net Start Components Sound Enclosure Compressor Sump Heat Optional Accessories: 4 Anti-short Cycle Timer Evaporator Defrost Control A/C Rubber Isolator Kit Snow Leg-Base & Cap 4" High Snow Leg-4" Extension Extreme Condition Mounting Kit Refrigerant Lineset 5 2TWB3042A1 200/230/1/60 21 35 CLIMATUFF® 15.4 - 93.5 1.4 1/6 27.6 Spine Fin™ 9/09-LB/OZ 7/8 3/8 46.4 x 35.1 x 38.7 308 272 YES YES YES 2TWB3048A1 200/230/1/60 25 40 CLIMATUFF® 18.6 - 93.4 1.4 1/5 27.6 Spine Fin™ 9/09-LB/OZ 1-1/8 3/8 46.4 x 35.1 x 38.7 312 276 YES YES YES 2TWB3060A1 208/230/1/60 32 50 CLIMATUFF® - SCROLL 25.0 - 148 1.2 1/5 27.6 Spine Fin™ 9/08-LB/OZ 1-1/8 3/8 46.4 x 35.1 x 38.7 291 255 NO NO YES TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT004 TAYREFLN3* TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT004 TAYREFLN4* TAYASCT501A AY28X084 BAYISLT101 BAYLEGS002 BAYLEGS003 BAYECMT004 TAYREFLN4* Accessory Description and Usage AHRI Standard Capacity Rating Conditions Anti-Short Cycle Timer — Solid state timing device that prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc. AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. Evaporator Defrost Control — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV. AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95°F outdoor air. Rubber Isolators — 5 large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized. Hard Start kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc. Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc. 22-1771-04 SPLIT SYSTEM 5 Model Nomenclature Outdoor Units 2 T W B 3 0 3 6 A 1 0 0 0 A A High Efficiency Furnaces Furnace Configuration TU = Upflow / Horizontal TD = Downflow / Horizontal Type D = 80% Premium X = 90% Premium Refrigerant Type 2 = R-22 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Number of Heating Stages 1 = Single Stage 2 = Two Stage 3 = Three Stage Cabinet Width A = 14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input 080 = 80,000 BTUH Major Design Change Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial Family SEER 0 = 10 3 = 13 1 = 11 4 = 14 2 = 12 5 = 15 6 = 16 8 = 18 9 = 19 Power Supply / Fuel 9 = 115 Volts / Natural Gas F = 115 Volts / Natural Gas with Integrated ifD Filter Airflow Capacity for Cooling 36 = 3 Ton Standard PSC Motor H3 = 3 Ton High Efficiency Motor V3 = 3 Ton Variable Speed Motor Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Draft Inducer Speeds 1 = Single Speed 2 = Two Speed V = Variable Speed Minor Design Change Service Digit – Not Orderable Secondary Function Minor Design Modifications Unit Parts Identifier Air Handlers – Residential T U D 1 B 0 8 0 A 9 H 3 1 A A 4 T E E 3 F 3 6 A 1 0 0 0 A A Heat Pump / Cooling Coils 2 T X C B 0 3 6 A C 3 H C A A Refrigerant Type 2 = R-22 4 = R-410A Product Family T = Premium (Heat Pump or Convertible Coil) C = Standard (Cooling Only) Coil Design X = Direct Expansion Evaporator Coil Product Family C = Cased A Coil A = Uncased A Coil F = Cased Horizontal Flat Coil Coil Width (Cased / Uncased) A = 14.5" / 13.3" C = 21.0" / 19.8" H = 10.5" B = 17.5" / 16.3" D = 24.5" / 23.3" Refrigerant Type 4 = R-410A 2 = R-22 Application TE = Fully Convertible TG = Semi Convertible TF = Front Return TV = Vertical Product Family E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic Flow Control 3 = Nonbleed TXV 4 = FCCV* Feature Identifier 0 = Standard Unit F = Air-Tite™ Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option – Factory Installed Heater Nominal KW Value Minor Design Modifications Unit Parts Identifier NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. *Shipped with R-22 FCCV Refrigerant Line Coupling 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Change Efficiency C = Standard S = Hi Efficiency Refrigerant Control 3 = TXV – Non-Bleed Coil Circuitry H = Heat Pump C = Cooling Only Airflow Configuration A = Upflow Only U = Upflow / Downflow H = Horizontal Only C = Convertible – Upflow, Downflow, Left Airflow M = Convertible – Upflow, Downflow, Left or Right Airflow Minor Design Change Unit Parts Identifier 6 22-1771-04 Electrical Data Schematic Diagrams (SEE LEGEND) 2TWB3018,024,030,036,042A 2TWB3048A Printed from D155596P01 Printed from D155595P01 22-1771-04 7 Electrical Data Schematic Diagrams 2TWB3060A LEGEND SYMBOLS 8 22-1771-04 Dimensions 2TWB3 Outline Drawing MODELS BASE FIG. 2TWB3018A 2 2 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 2TWB3024A 2 1 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 2TWB3030A 3 1 933 (36-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 5/16 143 (5-5/8) 92 (3-5/8) 2TWB3036A 4 1 943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 2TWB3042A 4 1 1045 (41-1/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 2TWB3048A 4 1 1045 (41-1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 2TWB3060A 4 1 1045 (41-1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 508 (20) 22-1771-04 A B C D 9 E F G H J K 57 (2-1/4) 181 (7-1/8) 44 (1-3/4) 457 (18) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18) 210 (8-1/4) 79 (3-1/8) 508 (20) From Dwg. 21D153074 Rev. 10 NOTE: ALL DIMENSIONS ARE IN MM (INCHES) Mechanical Specification Options General The 2TWB3 is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application. Casing Unit casing is constructed of heavy gauge, G90 galvanized steel and painted with a weather-resistant powder paint on all louvers, panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraTuff™ base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and low pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40° F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30° F. Accessories Thermostats — Cooling only and heat/ cooling (manual and automatic changeover). Sub-base to match thermostat and locking thermostat cover. Evaporator Defrost Control — See Low Ambient Cooling. Compressor The Climatuff® compressor features internal over temperature and pressure protection and total dipped hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and low vibration and noise. Literature Order Number File Number 01/11 Supersedes Stocking Location Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 10 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:829805a8-8c13-48c4-805a-6734d274d9e3 Producer : Acrobat Distiller 8.1.0 (Windows) Abstract : General Features, Features and Benefits. Acces flag : F Alt order nbr : Alt order nbr type : Bw color : B Date published : 01/01/2011 Dept id : 54 Topic focused id : TRANE|EN Price : 0 Cur flag : T Lit class id : PL Lit length : 10 Lit order nbr : 22-1771-04 Lit type id : PRD Media id : ELO Model : 2TWB3 Prod class : UN Prod family id : 2000541 Prod : SS Topic related id : TRN-FLD|SYS-DSN|RRR|OWN/DEV|DSGN|CONCPT|ARCH Restrct flag : F Source date : nulldate Source filename : Stocking loc id : None Supceded by : Supceded by date : nulldate Unit flag : T Branding : Trane Lol language : EN Object id : 090102b182516728 Object name : 22-1771-04_01012011 Chronicle id : 090102b1801c4f5f Filename : 82516728.pdf Hist model : 2TWB3018A1000BA|2TWB3024A1000BA|2TWB3030A1000BA|2TWB3036A1000BA|2TWB3042A1000BA|2TWB3048A1000BA|2TWB3060A1000BA Create Date : 2011:01:28 16:38:54-06:00 Creator Tool : PageMaker 7.0 Modify Date : 2011:01:28 16:53:59-06:00 Metadata Date : 2011:01:28 16:53:59-06:00 Document ID : uuid:b2e9ca75-fc2f-4b96-a4e5-157f1d54e726 Instance ID : uuid:9b8faf2f-304b-42b0-a364-95003ad8a7eb N Pages : 10 Format : application/pdf Title : 22-1771-04 01/01/2011 Trane Split System Heat Pump Product and Performance Data XB13 2TWB3018-060 1-1/2 - 5 Tons Creator : tylp Author : tylp Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : B Hist Model : 2TWB3018A1000BA|2TWB3024A1000BA|2TWB3030A1000BA|2TWB3036A1000BA|2TWB3042A1000BA|2TWB3048A1000BA|2TWB3060A1000BA Date Published : 01/01/2011 Dept Id : 54 Topic Focused Id : TRANE|EN Cur Flag : T Lit Class Id : PL Lit Length : 10 Lit Order Nbr : 22-1771-04 Lit Type Id : PRD Media Id : ELO Prod Class : UN Prod Family Id : 2000541 Topic Related Id : TRN-FLD|SYS-DSN|RRR|OWN/DEV|DSGN|CONCPT|ARCH Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : None Supceded By : Supceded By Date : nulldate Unit Flag : T Lol Language : EN Object Id : 090102b182516728 Object Name : 22-1771-04_01012011 Chronicle Id : 090102b1801c4f5fEXIF Metadata provided by EXIF.tools