Trane 36 Users Manual 22 1754 17 08/01/2011 Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048, 060E 2, 3, 4 And 5 Tons
48 to the manual 31680eb9-b753-4dcc-8146-d74b7bf404c1
2015-01-21
: Trane Trane-36-Users-Manual-236202 trane-36-users-manual-236202 trane pdf
Open the PDF directly: View PDF .
Page Count: 12
Download | |
Open PDF In Browser | View PDF |
Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048 & 060E 2, 3, 4 & 5 Tons PUB. NO. 22-1754-17 Features and Benefits • CLIMATUFF™ 2-stage scroll compressor • Efficiency up to 18.0 SEER and 9.0 HSPF • All Aluminum SPINE FIN™ coil • WEATHERGUARD™ II top shields unit • DURATUFF™ weather proof and rust proof base • COMFORT ”R”™ mode approved for better comfort indoors • QUICK-SESS™ cabinet, service access and refrigerant connections with full coil protection • WEATHERGUARD™ fasteners • Glossy corrosion resistant finish tarpaulin gray cabinet with anthracite gray top © 2011 Trane 2 • Internal compressor high/low • • • • • • • pressure & temperature protection Liquid line filter/drier Low sound with advanced variable speed fan motor Service valve cover R-410A refrigerant From 70 to 100% capacity modulation 100% run test in the factory Low ambient cooling to 55° as shipped • Extended warranties available 22-1754-17 Contents Features and Benefits 2 General Data 4 Product Specifications A-weighted Sound Power Level [dB(A)] Accessory Description and Usage AHRI Standard Capacity Rating Conditions 4 4 5 5 Model Nomenclature 6 Electrical Data 7 Dimensions 10 Mechanical Specifications 11 22-1754-17 3 General Data Product Specifications Model No. 1 4TWX6024E1 4TWX6036E1 4TWX6048E1 4TWX6060E1 Electrical Data V/Ph/Hz 2 230/1/60 230/1/60 230/1/60 230/1/60 Min Cir Ampacity 14 22 28 39 Max Fuse Size (Amps) 20 35 45 60 Compressor CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL RL AMPS - LR AMPS 10.3 - 52 16.7 - 82 21.2 - 104 28.8 - 152.9 Outdoor Fan FL Amps 0.74 0.74 1.00 2.80 Fan HP 1/8 1/8 1/5 1/3 Fan Dia (inches) 27.6 27.6 27.6 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-410A 10/3-LB/OZ 10/8-LB/OZ 12/9-LB/OZ 13/3-LB/OZ Line Size - (in.) O.D. Gas 3 5/8 3/4 7/8 1-1/8 Line Size - (in.) O.D. Liquid 3 3/8 3/8 3/8 3/8 Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 57.4 x 35.1 x 38.7 Weight - Shipping 305 307 360 361 Weight - Net 257 257 310 311 Start Components YES NO NO NO Sound Enclosure NO NO NO NO Compressor Sump Heat YES YES YES YES Optional Accessories: 4 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Vertical Discharge Air Kit Base 4 BAYVDTA003 BAYVDTA004 BAYVDTA004 BAYVDTA004 Auto Charge Solenoid Kit BAYCAKT001 BAYCAKT001 BAYCAKT001 BAYCAKT001 Refrigerant Lineset 5 TAYREFLN9* TAYREFLN7* TAYREFLN3* TAYREFLN4* 1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240. 2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses. 3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision) 4 For accessory description and usage, see page 5. 5 * = 15, 20, 25, 30, 40 and 50 foot lineset available. A-weighted Sound Power Level [dB(A)] MODEL SOUND POWER LEVEL [dB(A)] 4TWX6024E A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)] 72 63 40.4 125 50.8 250 53.7 500 59.9 1000 62.2 2000 57.9 4000 56.1 8000 48.4 4TWX6036E 72 39.3 49.6 55.7 60.5 62.9 57.7 54.7 47.3 4TWX6048E 72 42 57.3 56.6 64 63.3 57.2 53.5 46.2 57.1 64.8 66.4 59.8 55.9 51.2 4TWX6060E 74 31.9 58.9 Note: Rated in accordance with AHRI Standard 270-2008. 4 22-1754-17 General Data Accessory Description and Usage Rubber Isolators — 5 rubber donuts to isolate condensing unit from mounting frame or pad. Use on any application where sound transmission needs to be minimized. Extreme Conditions Mounting Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial rooftops, etc. Low Ambient Cooling — For low ambient cooling below 55° see Application Guide APP-APG013-EN. 22-1754-17 5 AHRI Standard Capacity Rating Conditions AHRI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.) S tandard Noise Rating number is at 95°F outdoor air. Model Nomenclature Gas Furnaces Outdoor Units T U D 2 B 0 8 0 A C V 3 2 A A 4 T W X 6 0 3 6 E 1 0 0 0 A A Refrigerant Type 4 = R-410A TRANE Product Type W = Split Heat Pump T = Split Cooling Product Family Z = Leadership – Two Stage X = Leadership R = Replacement/Retail M or B = Basic A = Light Commercial Family SEER 3 = 13 6 = 16 4 = 14 8 = 18 5 = 15 9 = 19 0 = 20 Split System Connections 1-6 Tons 0 = Brazed Nominal Capacity in 000s of BTUs Major Design Modifications Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications Unit Parts Identifier Air Handlers – Residential 4 T E E 3 F 3 6 A 1 0 0 0 A A Refrigerant Type 4 = R-410A Application TE = Fully Convertible TG = Semi Convertible TF = Front Return Product Family E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic Flow Control 0 = No Flow Control 3 = Nonbleed TXV Feature Identifier 0 = Standard Unit F = Air-Tite™ Nominal Capacity in 1000’s (BTUH) Major Design Change Power Supply 1 = Single Phase Electrical Connection 0 = Pig Tails B = Circuit Breaker D = Pull Disconnect Future Option – Factory Installed Heater Nominal KW Value Minor Design Modifications Unit Parts Identifier NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. Coils – Residential 4 T X C B 0 0 1 C C 3 H C A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible Coil) Coil Design X - Direct Expansion Evaporator Coil Product Family C - Cased A Coil A - Uncased A Coil F - Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A - 14.5" / 13.3" B - 17.5" / 16.3" C - 21.0" / 19.8" D - 24.5" / 23.3" H - 10.5" Refrigerant Line Coupling 0 - Brazed Model Number Distinguisher Major Design Change Efficiency C - Standard S - Hi Efficiency (Derived from 10 SEER products) Refrigerant Control 3 - TXV - Non-Bleed Coil Circuitry H - Heat Pump Airflow Configuration A - Upflow Only U - Upflow / Downflow H - Horizontal Only C - Convertible - Upflow, Downflow, Left or Right Airflow Minor Design Change Unit Parts Identifier 6 22-1754-17 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6024 Printed from D156993P02 22-1754-17 7 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6036E Printed from D156631P06 Rev 00 8 22-1754-17 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6048E 1 2 5 Printed from D156977 22-1754-17 9 Electrical Data Schematic Diagrams (SEE LEGEND) 4TWX6060E A C R - A /C R E C T I F I E R C BS - C OI L BOT T OM SE NSOR C F - F A N C A PA C I T OR T O POWE R SUPPL Y PE R UNI T NA M E PL A T E A ND L OC A L C ODE S C N - W I R E C ONNE C T OR C PR - C OM PR E SSOR C R - R UN C A PA C I T OR SU MP HT R BK PR /WH C SR - C A PA C I T OR SW I T C HI NG R E L A Y PR /WH DF C - DE F R OST C ONT R OL E E V - E L E C T R ONI C E X P V A L V E CS M S-1 RD BK/BL ST A R T K I T BA Y K SK T 263 BR/RD GR/YL BK C S - ST A R T I NG C A PA C I T OR T DL CSR -1 CSR BR 1 2 MS-2 BK /BL 5 E E V C - E L E C T R ONI C E X P V A L V E C ONT R OL F - I NDOOR F A N R E L A Y HPC O - HI GH PR E SSUR E C UT OUT SW I T C H I OL - I NT E R NA L OV E R L OA D PR OT E C T OR L PC O - L OW PR E SSUR E C UT OUT SW I T C H M S - C OM PR E SSOR M OT OR C ONT A C T OR ODA - OUT DOOR A NT I C I PA T OR BK /BL OF T - OUT DOOR F A N T HE R M OST A T OR ODS - OUT DOOR T E M PE R A T UR E SE NSOR CR I OL S R RD ODT - OUT DOOR T HE R M OST A T C RD B R /R D DFC LED GR K1 K1 T2 SC - SW I T C H OV E R V A L V E SOL E NOI D 1 BK Y Y O OR BK BL OR OR V A R IA B L E SPE E D A IR H A NDL E R O COM PR E SSOR SOL E NOID OR RD BL BL T Y PIC A L H E A T /COOL T H E R MOST A T Y lo NOT E 4 & 5 ODT -B YL/BK 3 1 Y 2C Y1 W3 X2 BK OPT IONA L ODT -A BK BK HE A T CONT R OL S W2 W2 W1 W1 BK YL/RD J G G YL HPCO YL/RD BL Y2C MS BL L PCO BL BL OR Y L RD Y L /BK O 3. L OW V OL T A GE WI R I NG T O BE NO. 18 A WG M I NI M U M C ONDU C T OR . 6. I F E L E C T R I C HE A T E R DOE S NOT HA V E A 3R D C ONT A C T OR (C H). C ONNE C T A JU M PE R WI R E F R OM W3 T O W2. I F E L E C T R I C HE A T E R DOE S NOT H A V E A 2ND C ONT A C T OR (BH). C ONNE C T A JU M PE R WI R E F R OM W2 T O W1. F B B R R O P-T R D EEVC 1. BE SU R E POWE R SU PPL Y A GR E E S WI T H E QU I PM E NT NA M E PL A T E . 5. I F ODT -B I S NOT U SE D, C ONNE C T A JU M PE R WI R E F R OM W3 T O W2. I F ODT -A I S NOT U SE D, C ONNE C T A JU M PE R WI R E F R OM W2 T O W1. B 7. X 2 M U ST BE C ONNE C T E D T O V A R I A BL E SPE E D A I R HA NDL E R T E R M I NA L W3 A S SHOWN, F OR PR OPE R I NDOOR A I R F L OW DU R I NG T HE DE F R OST C Y C L E 8. BE SU R E T HE JU M PE R BE T WE E N R A ND BK I S C U T OR R E M OV E D. R 9. WI T H O A ND Y /Y 2 E NE R GI Z E D, I NDOOR F A N I S A T 80% A I R F L OW. YL RD B R Y2 Y1 NOT E S: 4. ODT -B M U ST BE SE T L OWE R T HA N ODT -A BL BL RD CA UT I ON UNI T T E R M I NA L S A R E NOT DE SI GNE D T O A C C E PT OT HE R T Y PE S OF C ONDUC T OR S. F ailure to do so may cause damage to the equipment. 2. POWE R WI R I NG A ND GR OU NDI NG OF E QU I PM E NT M U ST C OM PL Y WI T H L OC A L C ODE S. T YL DI SC ONNE C T A L L E L E C T R I C A L POWE R I NC L UDI NG R E MOT E DI SC ONNE C T S BE FOR E SE R V I C I NG. F ailure to disconnect power before servicing can cause severe personal injury or death. USE C OPPE R C ONDUCT OR S ONL Y ! OPT IONA L R E MOT E BK WA R NI NG HA Z A R DOUS V OL T A GE ! Y2 BK Y2 YL BL 3 YL/RD 1 Y L /R D YL Y Y1 T DR S S WH WH O YL ACR T E M P - SE NSOR , T E M PE R A T UR E BK V A R I A BL E GR SPE E D BL OD F A N BR M OT OR WH YL ODS X2Y0 OR O SC T DL - DI SC HA R GE L I NE T HE R M OST A T T NS - T R A NSF OR M E R 6 BK R B B SM - SY ST E M ON-OF F SW I T C H T DR - T I M E DE L A Y R E L A Y (5 SE C DE L A Y ON) Y 2C - HI GH C A PA C I T Y C ONT R OL R E L A Y YL YL YL T1 Y L /BR CBS K2 K3 P-T R D - PR E SSUR E T R A NSDUC E R C PR BL GR /Y L BK/BL OR T NS 24V 10. WI T H O, Y /Y 2 A ND BK E NE R GI Z E D, I NDOOR F A N I S A T 100% A I R F L OW. F OR C A NA DIA N INST A L L A T IONS T E MP EEV POUR INST A L L A T IONS C A NA DIE NNE S CA UT ION: NOT SUIT A BL E F OR USE ON T O POWE R SU PPL Y PE R L OC A L C ODE S SY ST E M S E X CE E DING 150V -T O-GR OUND A T T E NT ION: NE CONV IE NT PA S A UX INST A L L A T IONS DE PL US DE 150 V A LA TERRE Printed from D156631P08 10 22-1754-17 Dimensions 4TWX6 Outline Drawing Note: All dimensions are in MM (Inches). MODELS BASE A B C D E F G H J K 4TWX6024E 4 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 5/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6036E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6048E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) 4TWX6060E 4 1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4) From Dwg. D152635 Rev. 16 22-1754-17 11 Mechanical Specifications General The 4TWX6 is fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit shall be certified to UL 1995. Exterior is designed for outdoor application. Condenser Coil The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this unit has a cooling capability to 55°F. For low ambient cooling below 55° see Application Guide APP-APG013-EN. Casing Unit casing is constructed of heavy gauge, G60 galvanized steel and painted with a weather-resistant powder paint on all louvers and panels. Corrosion and weatherproof CMBP-G30 DuraTuff™ base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The Climatuff® 2-stage compressor features internal over temperature and pressure protection and hermetic motor. Other features include: roto lock suction and discharge refrigerant connections, centrifugal oil pump and modular plugs for electrical connections. Trane www.trane.com 08/11 Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 12 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:93d264d7-77f6-4c01-93a7-80a123e77cd6 Producer : Adobe PDF Library 9.9 Trapped : False Acces flag : F Alt order nbr : Alt order nbr type : Bw color : B Date published : 08/01/2011 Dept id : 54 Topic focused id : EN|TRANE Price : 0 Cur flag : T Lit class id : PL Lit length : 12 Lit order nbr : 22-1754-17 Lit type id : PRD Media id : ELO Model : NONE Prod class : UN Prod family id : 115 Prod : SSP Topic related id : TRN-FLD|SYS-DSN|SERVICER|OWN/DEV|INST Restrct flag : F Source date : nulldate Source filename : Stocking loc id : None Supceded by : Supceded by date : 12/01/2007 Unit flag : T Branding : Trane Lol language : EN Object id : 090102b1828c157a Object name : 22-1754-17_08012011 Chronicle id : 090102b181f96fac Filename : 828c157a.pdf Abstract : Contains General Features, Features and Benefits, Optional Equipment, Low Outdoor Ambient Cooling, A.R.I. Standard Capacity Rating Conditions, Selection Procedure, Model Number Nomenclature, and General Data Hist model : 4TWX6024E1000AA|4TWX6036E1000AA|4TWX6048E1000A|4TWX6048E1000AA|4TWX6060E1000A|4TWX6060E1000AA Create Date : 2011:08:02 18:14:37-05:00 Modify Date : 2011:08:14 12:43:58-05:00 Metadata Date : 2011:08:14 12:43:58-05:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Instance ID : uuid:d487c533-0918-4c52-b422-684583f6abe2 Document ID : xmp.did:CE1AECDE5CBDE01180FF831DCACD75DC Rendition Class : proof:pdf Original Document ID : adobe:docid:indd:9064fae5-dc8d-11df-bcee-d6ba64d43fb9 Derived From Instance ID : xmp.iid:AE49A0DB51BDE01180FF831DCACD75DC Derived From Document ID : xmp.did:C0676FEA7E85E0119E4F9A7CF3F21536 Derived From Original Document ID: adobe:docid:indd:9064fae5-dc8d-11df-bcee-d6ba64d43fb9 Derived From Rendition Class : default History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:81E0D18CE97CE011953797CDA308AB91, xmp.iid:82E0D18CE97CE011953797CDA308AB91, xmp.iid:F88FB3BDEA7CE011953797CDA308AB91, xmp.iid:C02A8FE47E85E0119E4F9A7CF3F21536, xmp.iid:C0676FEA7E85E0119E4F9A7CF3F21536, xmp.iid:48549A828085E0119E4F9A7CF3F21536, xmp.iid:AE49A0DB51BDE01180FF831DCACD75DC, xmp.iid:CE1AECDE5CBDE01180FF831DCACD75DC, xmp.iid:FEE5002E5DBDE01180FF831DCACD75DC History When : 2011:05:12 17:45:35-05:00, 2011:05:12 17:45:35-05:00, 2011:05:12 17:54:06-05:00, 2011:05:23 15:54:56-05:00, 2011:05:23 15:54:56-05:00, 2011:05:23 16:06:21-05:00, 2011:08:02 18:12:19-05:00, 2011:08:02 18:12:19-05:00, 2011:08:02 18:14:32-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /metadata, /;/metadata, /;/metadata, /metadata, /;/metadata, /;/metadata N Pages : 12 Doc Change Count : 63 Format : application/pdf Title : 22-1754-17 08/01/2011 Trane Split System Heat Pump Product Data XL16i 4TWX6024, 036, 048, 060E 2, 3, 4 and 5 Tons Tagged PDF : Yes Creator : Adobe InDesign CS5 (7.0.4) Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : B Hist Model : 4TWX6024E1000AA|4TWX6036E1000AA|4TWX6048E1000A|4TWX6048E1000AA|4TWX6060E1000A|4TWX6060E1000AA Date Published : 08/01/2011 Dept Id : 54 Topic Focused Id : EN|TRANE Cur Flag : T Lit Class Id : PL Lit Length : 12 Lit Order Nbr : 22-1754-17 Lit Type Id : PRD Media Id : ELO Prod Class : UN Prod Family Id : 115 Topic Related Id : TRN-FLD|SYS-DSN|SERVICER|OWN/DEV|INST Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : None Supceded By : Supceded By Date : 12/01/2007 Unit Flag : T Lol Language : EN Object Id : 090102b1828c157a Object Name : 22-1754-17_08012011 Chronicle Id : 090102b181f96facEXIF Metadata provided by EXIF.tools