Trane 4Ycy4024A Users Manual 22 1797 03 05/01/2008 Product Data 14 SEER Single Packaged Convertible Gas/Electric, 2 5 Ton, 40 120 KBTU, R 410A Mode
4YCY4024A Trane-XL14c-Package-Gas-Electric-Product-Data-Specifications
4YCY4060A to the manual f7cc551a-9cf4-4089-9396-dc2c5145d07a
2015-01-21
: Trane Trane-4Ycy4024A-Users-Manual-236228 trane-4ycy4024a-users-manual-236228 trane pdf
Open the PDF directly: View PDF .
Page Count: 29
Download | |
Open PDF In Browser | View PDF |
22-1797-03 Product Data 4YCY4024A through 4YCY4060A Single Packaged Convertible Gas/Electric 14 SEER 2 - 5 Ton, 40 - 120 KBTU R-410A © 2008 Trane Pub. No. 22-1797-03 It's Hard to Stop a Trane. Single Packaged Convertible Gas/Electric System Trane offers a complete family of packaged gas/electric heating and cooling systems, designed to give you the unbeatable combination of energy efficiency and lower operating costs. In warm weather, the packaged gas/electric system functions as an all-electric, high efficiency air conditioner. In cold weather, it operates as a natural gas or propane gas furnace, offering you the best of both energy worlds. Introducing the new TRANE Single Packaged Convertible Gas/Electric System. Single Packaged Convertible Gas/ Electric Systems are easy and versatile to install. Because cooling and heating functions are all contained in a single cabinet, a Trane single packaged convertible gas/electric system is easy to install and service. It can be flush mounted beside your home at ground level or placed on the roof for horizontal or downflow installation. When connected to an optional Trane thermostat control, and air distribution ducts, you have a highly efficient, total home comfort system. Single Packaged Convertible Gas/ Electric Systems are unmatched in quality and reliability. All major components on these products, including the compressor, have been designed and manufactured for maximum service. Every Climatuff® compressor is designed and manufactured to exacting specifications. Each design is life tested in extreme environments to ensure reliable and long lasting operation in normal applications. Each compressor has internal motor protection for added reliability. 2 Contents Optional Equipment Listing 4 General Data 5 Performance Data 3 Cooling Indoor Fan 9 11 Typical Wiring 15 Optional Equipment 18 Dimensional Data 23 Mechanical Specifications 29 Optional Equipment Listing ✓ ] indicates accessories included) OPTIONAL EQUIPMENT FOR PACKAGED UNITS (check mark [✓ Hinged Filter Access Door (4YCY4024-036) 8 ................................................................ BAYACCDOR1A[ Hinged Filter Access Door (4YCY4042-060) 8 ................................................................ BAYACCDOR2A[ Roof Curb Full Perimeter (4YCY4024-36A) 3 ................................................................... BAYCURB050A[ Roof Curb Full Perimeter (4YCY4042-60A) 3 ................................................................... BAYCURB051A[ Roof Curb Utility Extension Kit (BAYCURB050A) ................................................................. BAYUTIL101B[ Roof Curb Utility Extension Kit (BAYCURB051A) ................................................................. BAYUTIL102B[ 0-25% Manual Fresh Air Damper (4YCY4024-36A) 1. ...................................................... BAYOSAH001A[ 0-25% Manual Fresh Air Damper (4YCY4042-60A) 1. ...................................................... BAYOSAH002A[ Motorized Fresh Air Damper (4YCY4024-36A) 1. ............................................................ BAYDMPR101A[ Motorized Fresh Air Damper (4YCY4042-60A) 1. ............................................................. BAYDMPR102A[ 16" Round Duct Adapter (2 per box) (4YCY4024-36A) 6 ................................................. BAYSQRD001A[ 18" Round Duct Adapter (2 per box) (4YCY4024-60A) 6 ................................................. BAYSQRD002A[ 0-100% Mod Economizer w/Baro. Relief (4YCY4024-36A) 124 .................................... BAYECON101B[ 0-100% Mod. Economizer w/Baro. Relief (4YCY4042-60A) 124. .................................. BAYECON102B[ 0-100% Horizontal Economizer (4YCY4024-36A) 12 . .................................................... BAYECON200A[ 0-100% Horizontal Economizer (4YCY4042-60A) 12 . .................................................... BAYECON201A[ Enthalpy Control for Economizer (solid state). .................................................................... BAYENTH001A[ Remote Potentiometer (All-BAYECON***A) ............................................................................ BAYSTAT023[ 1"-2" Filter Frame (4YCY4024-36A) (20 x 25 filter not included) 1. .................................... BAYFLTR101B[ 1"-2" Filter Frame (4YCY4042-60A) (20 x 20 & 20 x 18 filter not included) 1. ................... BAYFLTR201B[ LP Conversion Kit (All 40K, 120K Models) ........................................................................... BAYLPKT100A[ LP Conversion Kit (All 64K, 96K Models) ............................................................................. BAYLPKT101A[ LP Conversion Kit (All 75K Models) ..................................................................................... BAYLPKT102A[ Head Pressure Control (Low Ambient Cool) (208/240v) Kit 5. ......................................... BAYLOAM105A[ Quick Start Kit (4YCY4-A1) .................................................................................................. BAYQSKT301A[ Crankcase Heater Recip (4YCY4024A1 (230v) 5. ............................................................. BAYCCHT101A[ Crankcase Heater Scroll (4YCY4036-060A1/3)(230v) 5. .................................................. BAYCCHT102A[ Adapter Curb 4YCY4024-036A to BAYCURB030,38 ........................................................ BAYADAP050A[ Adapter Curb 4YCY4024-036A to BAYCURB033 ............................................................. BAYADAP051A[ Adapter Curb 4YCY4042-060A to BAYCURB030,38 ........................................................ BAYADAP052A[ Adapter Curb 4YCY4042-060A to BAYCURB033 ............................................................. BAYADAP053A[ Adapter Curb 4YCY4042-060A to BAYCURB034 ............................................................. BAYADAP054A[ 12" Duct Shroud Covers Horizontal 4YCY4024-060A7. ................................................... BAYCOVR112A[ 18" Duct Shroud Covers Horizontal 4YCY4024-060A 7. .................................................. BAYCOVR118A[ Extreme Condition Mounting Kit - All BAYCURB & BAYADAP ......................................... BAYEXMK001A[ Extreme Condition Mounting Kit - All BAYUTIL .................................................................. BAYEXMK002B[ Extreme Condition Mounting Kit - All Slab Mounts ............................................................. BAYEXMK003A[ Lifting Lug Kit .......................................................................................................................... BAYLlFT002B[ NOTES: ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] 1 Must use filter frame when economizer/fresh air kit is used. 2 Dry bulb control standard with economizer. 3 Ships knocked down. 4 Downflow only. 5 Low Ambient cooling requires crankcase heater (BAYCCHT----A). 6 It is the responsibility of the installing dealer to properly size the ductwork for each specific application. 7 BAYCOVR112,118A will not cover BAYSQRD002A applications 8 BAYACCDOR1A requires BAYFLTR101B & BAYACCDOR2A requires BAYFLTR201B. They are not backward compatible to BAYFLTR101/201A. 4 General Data 4YCY4024A1064A MODEL 208-230/1/60 RATED Volts/PH/Hz 23400 Performance Cooling BTUHj 790 Indoor Airflow (CFM) 2.162 Power Input (KW) 11.6 / 14.0 EER/SEER(BTU/Watt-Hr.)n 68 Sound Power Rating [dB(A)]8 Performance Heatingk 48000 Input BTUH - 1st Stage (Natural Gas)p 64000 Input BTUH - 2nd Stage (Natural Gas)p 79.0 AFUE 35 / 65 Temp. Rise — Min/Max (°F) 2 / #37 Orifice Qty / Drill Size (Natural Gas)l 208-230/1/60 POWER CONN.—V/PH/HZ 16.5 Min. Brch. Cir. Ampacitym 25 Fuse Size — Max. (amps) 25 Fuse Size — Recmd. (amps) RECIPROCATING COMPRESSOR 208-230/1/60 Volts/Ph/Hz 8.3 / 57.8 R.L. Amps — L.R. Amps SPINE-FIN OUTDOOR COIL — TYPE 2 / 24 Rows/F.P.I. 13.32 Face Area (sq.ft.) 3/8 Tube Size (in.) PLATE FIN INDOOR COIL — TYPE 3 / 15 Rows/F.P.I. 3.54 Face Area (sq.ft.) 3/8 Tube Size (in.) EXPANSION VALVE Refrigerant Control 3/4 FEMALE NPT Drain Conn. Size (in.) PROPELLER OUTDOOR FAN — TYPE 23.4 Dia. (in.) DIRECT / 1 Drive/No. Speeds 1/12 / 810 Motor — HP/R.P.M. 208-230/1/60 Volts/Ph/Hz 0.54 / 0.95 F.L. Amps/L.R. Amps CENTRIFUGAL INDOOR FAN — TYPE 10 X 10 Dia x Width (in.) DIRECT / VARIABLE Drive/No. Speeds SEE FAN PERF TABLE CFM @ 0.0 in. w.g.n 1/2 / VARIABLE Motor — HP/R.P.M. 200-230/1/60 Volts/Ph/Hz 4.3 / 4.3 F.L. Amps/L.R. Amps CENTRIFUGAL COMBUSTION FAN — TYPE DIRECT / 2 Drive/No. Speeds 1/45 / 2800/1500 Motor — HP/R.P.M. 208-230/1/60 Volts/Ph/Hz 0.34 FLA NO FILTER / FURNISHED THROWAWAY Type Recommended 4.0 Recmd. Face Area (sq. ft.)o R410A REFRIGERANT 5.8 Charge (lbs.)m 1/2 GAS PIPE SIZE (in.) HXWXL DIMENSIONS 45.86 / 44.5 / 52.03 Crated (in.) WEIGHT 481 / 385 Shipping (lbs.) / Net (lbs.) 4YCY4030A1075A 208-230/1/60 30000 900 2.5 12.0 / 14.0 71 4YCY4036A1075A 208-230/1/60 36000 1210 3.284 11.6 / 14.2 69 4YCY4036A1096A 208-230/1/60 36000 1210 3.284 11.6 / 14.2 69 56250 75000 79.5 30 / 60 2 / #33 208-230/1/60 19.2 30 30 RECIPROCATING 200-230/1/60 11.1 / 63 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 3 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 1/6 / 830 208-230/1/60 1.0 / 1.7 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1/2 / VARIABLE 208-230/1/60 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 4.0 R410A 6.0625 1/2 HXWXL 45.86 / 44.5 / 52.03 56250 75000 79.5 30 / 60 2 / #33 208-230/1/60 24.6 40 40 SCROLL 208-230/1/60 15.4 / 83 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1/2 / VARIABLE 200-230/1/60 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 4.0 R410A 6.75 1/2 HXWXL 47.86 / 44.5 / 52.03 72000 96000 80.0 40 / 70 3 / #37 208-230/1/60 24.6 40 40 SCROLL 208-230/1/60 15.4 / 83 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1/2 / VARIABLE 200-230/1/60 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 4.0 R410A 6.75 1/2 HXWXL 47.86 / 44.5 / 52.03 481 / 385 488 / 392 493 / 397 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 8 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 5 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUHj Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. Cir. Ampacitym Fuse Size — Max. (amps) Fuse Size — Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps — L.R. Amps OUTDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN — TYPE Dia. (in.) Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN — TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.n Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN — TYPE Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.)o REFRIGERANT Charge (lbs.)m GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCY4036A3075A 208-230/3/60 36000 1210 3.284 11.6 / 14.2 69 4YCY4036A3096A 208-230/3/60 36000 1210 3.284 11.6 / 14.2 69 4YCY4042A1096A 208-230/1/60 42000 1350 3.5 12.0 / 14.25 74 56250 75000 80.0 30 / 60 2 / #33 208-230/3/60 19.8 30 30 SCROLL 208-230/3/60 11.5 / 77 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1/2 / VARIABLE 200-230/1/60 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 4.0 R410A 6.75 1/2 HXWXL 47.86 / 44.5 / 52.03 72000 96000 80.0 40 / 70 3 / #37 208-230/3/60 19.8 30 30 SCROLL 208-230/3/60 11.5 / 77 SPINE-FIN 2 / 24 15.49 3/8 PLATE FIN 4 / 15 3.54 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 23.4 DIRECT / 1 1/5 / 830 208-230/1/60 1.1 / 1.9 CENTRIFUGAL 10 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1/2 / VARIABLE 200-230/1/60 4.3 / 4.3 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 4.0 R410A 6.75 1/2 HXWXL 47.86 / 44.5 / 52.03 72000 96000 80 30 / 60 3 / #37 208-230/1/60 31.5 50 50 SCROLL 208-230/1/60 18.6 / 105 SPINE-FIN 2 / 24 23.57 3/8 PLATE FIN 3 / 15 5 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/4 / 825 208-230/1/60 1.5 / 3.4 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 3/4 / VARIABLE 208-230/1/60 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 6.8125 1/2 HXWXL 47.86 / 47.4 / 61.75 488 / 392 493 / 397 653 / 525 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 8 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 6 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUHj Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. Cir. Ampacitym Fuse Size — Max. (amps) Fuse Size — Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps — L.R. Amps OUTDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN — TYPE Dia. (in.) Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN — TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.n Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN — TYPE Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.)o REFRIGERANT Charge (lbs.)m GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCY4048A1096A 208-230/1/60 48000 1605 4.034 11.9 / 14.2 73 4YCY4048A1120A 208-230/1/60 48000 1605 4.034 11.9 / 14.2 73 4YCY4048A3096A 208-230/3/60 48000 1605 4.034 11.9 / 14.2 73 72000 96000 80.0 30 / 60 3 / #37 208-230/1/60 33.8 50 50 SCROLL 208-230/1/60 20.5 / 109 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 8.2 1/2 HXWXL 47.86 / 47.4 / 61.75 90000 120000 80.0 40 / 70 3 / #32 208-230/1/60 33.8 50 50 SCROLL 208-230/1/60 20.5 / 109 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/4 / 825 208-230/1/60 1.4 / 3.37 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 8.2 1/2 HXWXL 47.86 / 47.4 / 61.75 72000 96000 80.0 30 / 60 3 / #37 208-230/3/60 26.4 40 40 SCROLL 208-230/3/60 14.6 / 91 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/4 / 825 208-230/1/60 1.4 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 8.2 1/2 HXWXL 47.86 / 47.4 / 61.75 653 / 525 659 / 531 653 / 525 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 8 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 7 General Data MODEL RATED Volts/PH/Hz Performance Cooling BTUHj Indoor Airflow (CFM) Power Input (KW) EER/SEER(BTU/Watt-Hr.)n Sound Power Rating [dB(A)]8 Performance Heatingk Input BTUH - 1st Stage (Natural Gas)p Input BTUH - 2nd Stage (Natural Gas)p AFUE Temp. Rise — Min/Max (°F) Orifice Qty / Drill Size (Natural Gas)l POWER CONN.—V/PH/HZ Min. Brch. Cir. Ampacitym Fuse Size — Max. (amps) Fuse Size — Recmd. (amps) COMPRESSOR Volts/Ph/Hz R.L. Amps — L.R. Amps OUTDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) INDOOR COIL — TYPE Rows/F.P.I. Face Area (sq.ft.) Tube Size (in.) Refrigerant Control Drain Conn. Size (in.) OUTDOOR FAN — TYPE Dia. (in.) Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps INDOOR FAN — TYPE Dia x Width (in.) Drive/No. Speeds CFM @ 0.0 in. w.g.n Motor — HP/R.P.M. Volts/Ph/Hz F.L. Amps/L.R. Amps COMBUSTION FAN — TYPE Drive/No. Speeds Motor — HP/R.P.M. Volts/Ph/Hz FLA FILTER / FURNISHED Type Recommended Recmd. Face Area (sq. ft.)o REFRIGERANT Charge (lbs.)m GAS PIPE SIZE (in.) DIMENSIONS Crated (in.) WEIGHT Shipping (lbs.) / Net (lbs.) 4YCY4048A3120A 208-230/3/60 48000 1605 4.034 11.9 / 14.2 73 4YCY4060A1120A 208-230/1/60 58500 1800 5.478 11.9 / 14.0 76 4YCY4060A3120A 208-230/3/60 58500 1800 5.478 11.9 / 14.0 76 90000 120000 80.0 40 / 70 3 / #32 208-230/3/60 26.4 40 40 SCROLL 208-230/3/60 14.6 / 91 SPINE-FIN 2 / 24 18.01 3/8 PLATE FIN 3 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/4 / 825 208-230/1/60 1.4 / 3.37 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 3/4 / VARIABLE 200-230/1/60 6.8 / 6.8 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 8.2 1/2 HXWXL 47.86 / 47.4 / 61.75 90000 120000 80.0 30 / 60 3 / #32 208-230/1/60 42.3 60 60 SCROLL 208-230/1/60 26.9 / 145 SPINE-FIN 2 / 24 23.07 3/8 PLATE FIN 4 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/3 / 830 208-230/1/60 1.7 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1 / VARIABLE 208-230/1/60 6.9 / 6.9 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 9.75 1/2 HXWXL 51.86 / 47.4 / 61.75 90000 120000 80.0 30 / 60 3 / #32 208-230/3/60 30.6 45 45 SCROLL 208-230/3/60 17.6 / 123 SPINE-FIN 2 / 24 23.07 3/8 PLATE FIN 4 / 15 5.0 3/8 EXPANSION VALVE 3/4 FEMALE NPT PROPELLER 28.2 DIRECT / 1 1/3 / 830 208-230/1/60 1.7 / 3.5 CENTRIFUGAL 11 X 10 DIRECT / VARIABLE SEE FAN PERF TABLE 1 / VARIABLE 208-230/1/60 6.9 / 6.9 CENTRIFUGAL DIRECT / 2 1/45 / 2800/1500 208-230/1/60 0.34 NO THROWAWAY 5.3 R410A 9.75 1/2 HXWXL 51.86 / 47.4 / 61.75 659 / 531 676 / 548 676 / 548 1 Certified in accordance with the Unitary Air-Conditioner Equipment certification program, which is based on ARI Standard 210/240. Noise calculated in accordance with A.R.I. Standard 270. 2 All models are U L Listed. Ratings shown are for elevations up to 2000 ft. For higher elevations reduce ratings at a rate of 4% per 1000 ft. elevation. 3 Convertible to LPG. 4 This value is approximate. For more precise value, see Unit Nameplate. 5 Based on U.S. Government Standard Tests. 6 Filters must be installed in return air stream. Square footages listed are based on 300 f.p.m. face velocity. If permanent filters are used size per manufacturer's recommendation with a clean resistance of 0.05" W.C. 7 Unit is shipped on high input, unit is convertible to low input with a Low Fire accessory kit. 8 Sound Power values are not adjusted for ARI 270-95 tonal corrections. 8 Performance Data Cooling 4YCY4030A1 AT 1000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 29.8 31.0 33.4 36.1 SENS CAP AT ENTERING DB TEMP 72 75 78 80 24.1 26.9 29.2 28.9 19.7 22.6 25.5 27.4 15.8 18.6 21.5 23.4 11.8 14.6 17.5 19.4 TOTAL KW 2.3 2.3 2.3 2.3 95 59 63 67 71 27.3 28.5 30.7 33.1 23.0 18.7 14.7 10.7 25.8 21.5 17.6 13.6 27.3 24.4 20.4 16.5 27.3 26.3 22.3 18.4 2.5 2.5 2.5 2.5 105 59 63 67 71 24.8 25.9 27.9 30.1 21.9 17.6 13.7 9.7 24.7 20.5 16.5 12.6 24.8 23.3 19.4 15.4 24.8 25.2 21.3 17.4 2.7 2.7 2.7 2.7 115 59 63 67 71 22.4 23.3 25.1 27.1 20.8 16.6 12.7 8.7 22.4 19.5 15.5 11.6 22.4 22.3 18.4 14.4 22.4 23.3 20.3 16.4 2.9 2.9 2.9 2.9 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 875 0.97 0.98 HIGH 1125 1.03 1.02 CFM 890 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 30000 14.00 EER 12.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 4YCY4024A1 AT 800 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 22.9 23.9 25.8 27.8 SENS CAP AT ENTERING DB TEMP 72 75 78 80 19.1 21.4 22.9 22.9 15.6 17.9 20.2 21.8 12.3 14.7 17.0 18.6 9.1 11.5 13.8 15.3 TOTAL KW 1.8 1.8 1.9 1.9 95 59 63 67 71 20.9 21.8 23.5 25.3 18.2 14.7 11.5 8.3 20.5 17.0 13.8 10.6 20.9 19.3 16.1 12.9 20.9 20.9 17.7 14.5 2.0 2.0 2.0 2.0 105 59 63 67 71 18.8 19.6 21.1 22.8 17.3 13.8 10.6 7.4 18.8 16.1 12.9 9.7 18.8 18.5 15.3 12.1 18.8 19.6 16.8 13.6 2.1 2.1 2.2 2.2 115 59 63 67 71 16.7 17.5 18.8 20.3 16.4 13.0 9.8 6.6 16.7 15.3 12.1 8.9 16.7 17.5 14.4 11.2 16.7 17.5 16.0 12.8 2.3 2.3 2.3 2.3 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 700 0.97 0.98 HIGH 900 1.03 1.02 CFM 790 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 23400 14.00 EER 11.60 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 4YCY4036A1/3 AT 1200 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 34.5 36.0 38.8 41.9 SENS CAP AT ENTERING DB TEMP 72 75 78 80 28.8 32.4 34.5 34.5 23.4 27.0 30.5 32.9 18.5 22.0 25.6 27.9 13.5 17.1 20.6 23.0 TOTAL KW 2.7 2.7 2.8 2.8 95 59 63 67 71 32.0 33.4 35.9 38.8 27.6 22.3 17.4 12.4 31.2 25.9 20.9 16.0 32.0 29.4 24.5 19.6 32.0 31.8 26.9 21.9 3.0 3.1 3.1 3.1 105 59 63 67 71 29.5 30.7 33.1 35.7 26.5 21.2 16.3 11.4 29.5 24.8 19.9 15.0 29.5 28.4 23.4 18.5 29.5 30.7 25.8 20.9 3.3 3.4 3.4 3.4 115 59 63 67 71 26.9 28.1 30.2 32.7 25.4 20.2 15.3 10.4 26.9 23.7 18.8 13.9 26.9 27.3 22.4 17.5 26.9 28.1 24.8 19.9 3.6 3.7 3.7 3.7 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1050 0.97 0.98 HIGH 1350 1.03 1.02 CFM 1210 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 36000 14.20 EER 11.60 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 9 Performance Data Cooling 4YCY4042A1 AT 1400 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 40.3 42.0 45.3 48.9 SENS CAP AT ENTERING DB TEMP 72 75 78 80 34.1 38.4 40.3 40.3 27.7 31.9 36.2 39.0 21.8 26.1 30.3 33.2 15.9 20.2 24.4 27.3 TOTAL KW 3.1 3.1 3.2 3.2 95 59 63 67 71 37.6 39.2 42.2 45.6 32.9 26.6 20.7 14.8 37.2 30.8 24.9 19.1 37.6 35.1 29.2 23.3 37.6 37.9 32.0 26.2 3.4 3.5 3.5 3.5 105 59 63 67 71 34.9 36.4 39.2 42.3 31.7 25.4 19.6 13.7 34.9 29.7 23.8 18.0 34.9 33.9 28.1 22.2 34.9 36.4 30.9 25.1 3.8 3.8 3.8 3.8 115 59 63 67 71 32.2 33.6 36.2 39.0 30.5 24.3 18.5 12.6 32.2 28.6 22.7 16.8 32.2 32.8 26.9 21.1 32.2 33.6 29.8 23.9 4.1 4.1 4.2 4.2 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1225 0.97 0.98 HIGH 1575 1.03 1.02 CFM 1360 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 42000 14.25 EER 12.00 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 4YCY4048A1/3 AT 1600 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 45.3 47.2 50.9 55.0 SENS CAP AT ENTERING DB TEMP 72 75 78 80 38.2 42.9 45.3 45.3 31.0 35.7 40.5 43.7 24.4 29.1 33.9 37.1 17.7 22.5 27.3 30.4 TOTAL KW 3.6 3.6 3.7 3.7 95 59 63 67 71 42.7 44.5 48.0 51.8 37.0 29.8 23.2 16.7 41.7 34.6 28.0 21.4 42.7 39.3 32.8 26.2 42.7 42.6 36.0 29.4 3.9 4.0 4.0 4.0 105 59 63 67 71 40.1 41.8 45.0 48.6 35.8 28.7 22.2 15.6 40.1 33.5 27.0 20.4 40.1 38.3 31.7 25.1 40.1 41.4 34.9 28.3 4.3 4.4 4.4 4.4 115 59 63 67 71 37.5 39.1 42.1 45.5 34.7 27.7 21.1 14.5 37.5 32.4 25.8 19.3 37.5 37.2 30.6 24.0 37.5 39.1 33.8 27.2 4.7 4.7 4.8 4.8 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1400 0.97 0.98 HIGH 1800 1.03 1.02 CFM 1605 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 48000 14.20 EER 11.90 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 4YCY4060A1/3 AT 2000 NOM CFM (COOLING PERFORMANCE AT INDOOR DRY BULB TEMPERATURES) OD AMB ID WB 59 63 67 71 TOT CAP 56.5 58.9 63.5 68.5 SENS CAP AT ENTERING DB TEMP 72 75 78 80 47.6 53.5 56.5 56.5 38.5 44.5 50.5 54.4 30.2 36.2 42.2 46.2 21.9 27.8 33.8 37.8 TOTAL KW 4.4 4.4 4.5 4.5 95 59 63 67 71 53.1 55.4 59.7 64.4 46.0 37.0 28.8 20.5 52.0 43.1 34.8 26.4 53.1 49.0 40.7 32.4 53.1 53.0 44.8 36.4 4.8 4.9 5.0 5.0 105 59 63 67 71 49.7 51.9 55.9 60.3 44.5 35.7 27.4 19.1 49.7 41.6 33.3 25.0 49.7 47.6 39.3 31.0 49.7 51.6 43.3 35.0 5.3 5.3 5.4 5.4 115 59 63 67 71 46.4 48.3 52.1 56.2 43.0 34.2 26.0 17.7 46.4 40.2 32.0 23.7 46.4 46.2 37.9 29.6 46.4 48.3 41.9 33.7 5.8 5.8 5.9 5.9 85 USE THE FOLLOWING FACTORS TO COMPENSATE FOR DIFFERENT AIR FLOW AIR FLOW CAPACITY TOTAL POWER RATE, CFM MULTIPLIER MULTIPLIER LOW 1750 0.97 0.98 HIGH 2250 1.03 1.02 CFM 1799 ARI RATING FOR COOLING CAPACITY (A) TEST SEER 58500 14.00 EER 11.90 ARI Standard Capacity Rating Conditions ARI STANDARD 210/240 RATING CONDITIONS — (A) Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. (B) High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (C) Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. (D) Rated indoor airflow for heating is the same as for cooling. 10 Indoor Blower Performance Indoor Fan Performance 4YCY4024A Horizontal Airflow 4YCY4024A-HOR Motor Speed LOW MED* HIGH External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Watts 52 66 89 115 140 164 186 206 CFM 706 716 727 733 731 719 700 679 Watts 94 120 148 177 207 233 254 CFM - 793 805 813 813 806 793 780 Watts - 125 153 182 211 243 284 CFM - 877 892 903 904 897 884 0.8 229 662 267 778 342 869 0.9 259 659 290 799 426 863 1 300 682 320 800 551 877 External Static Pressure (in. wg) 0.2 0.3 0.4 0.5 0.6 0.7 90 108 131 160 188 204 734 728 721 715 705 679 105 129 155 180 206 232 802 810 816 813 803 794 127 156 185 213 242 275 882 899 909 907 895 886 0.8 240 675 264 800 319 898 0.9 270 680 306 820 345 910 1 320 685 364 810 385 900 Down Airflow 4YCY4024A-DOWN Motor Speed 0 Watts 35 CFM 695 Watts 79 CFM 846 Watts 86 CFM 884 LOW MED* HIGH 0.1 70 729 87 807 102 870 Indoor Fan Performance 4YCY4030A Horizontal Airflow 4YCY4030A-HOR Motor Speed 350 CFM 400 CFM* 450 CFM Watts CFM Watts CFM Watts CFM - 0 0.1 0.2 113 880 146 996 195 1122 148 905 184 1009 233 1132 176 917 215 1013 267 1134 External Static Pressure (in. wg) 0.3 0.4 0.5 0.6 203 918 243 1012 303 1136 233 913 272 1008 340 1138 263 906 303 1003 371 1133 291 901 330 1000 388 1107 0.7 0.8 0.9 309 907 348 997 373 1039 306 930 347 994 - 267 979 312 991 - 1 - Down Airflow 4YCY4030A-DOWN Motor Speed 350 CFM 400 CFM* 450 CFM Watts CFM Watts CFM Watts CFM - 0 0.1 112 871 152 990 191 1090 147 894 185 995 227 1099 External Static Pressure (in. wg) 0.2 0.3 0.4 0.5 0.6 0.7 172 898 211 992 258 1095 198 893 238 984 289 1091 227 884 269 974 321 1091 *Factory Default Setting 11 259 874 303 964 355 1089 288 864 333 955 392 1071 303 851 349 946 432 1011 0.8 0.9 286 828 334 937 - 217 788 271 925 - 1 - Indoor Blower Performance Indoor Fan Performance 4YCY4036A Horizontal Airflow 4YCY4036A-HOR Motor Speed LOW MED* HIGH External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 162 173 197 226 256 285 313 343 383 440 525 CFM 1058 1062 1063 1063 1062 1060 1057 1053 1048 1042 1033 Watts 179 230 265 296 329 366 403 431 450 485 555 CFM 1179 1196 1204 1206 1205 1203 1199 1194 1185 1169 1144 Watts 318 336 365 399 435 469 502 533 563 CFM 1390 1376 1370 1366 1361 1354 1349 1351 1369 - Down Airflow 4YCY4036A-DOWN Motor Speed LOW MED* HIGH External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 169 182 210 243 273 301 331 370 433 480 530 CFM 1025 1062 1068 1063 1060 1061 1064 1055 1015 975 990 Watts 225 253 283 315 348 381 414 449 484 522 575 CFM 1187 1201 1203 1201 1198 1197 1194 1184 1157 1165 1150 Watts 339 357 390 424 455 483 516 571 669 CFM 1391 1377 1377 1375 1366 1352 1344 1360 1340 - Indoor Fan Performance 4YCY4042A Horizontal Airflow 4YCY4042A-HOR Motor Speed 350 CFM 400 CFM* 450 CFM Watts CFM Watts CFM Watts CFM 0 0.1 - 160 1206 231 1389 326 1582 0 0.1 - 176 1207 253 1405 367 1599 External Static Pressure (in. wg) 0.2 0.3 0.4 0.5 0.6 0.7 185 1211 261 1398 362 1592 214 1213 292 1405 393 1593 245 1215 325 1409 421 1587 277 1215 359 1410 450 1577 308 1214 394 1408 482 1566 339 1212 431 1403 517 1557 0.8 0.9 1 368 1208 467 1399 556 1553 396 1201 503 1396 597 1556 423 1190 536 1399 - Down Airflow 4YCY4042A-DOWN Motor Speed 350 CFM 400 CFM* 450 CFM Watts CFM Watts CFM Watts CFM External Static Pressure (in. wg) 0.2 0.3 0.4 0.5 0.6 0.7 203 1214 290 1411 379 1577 232 1217 323 1413 409 1570 262 1216 355 1412 446 1569 *Factory Default Setting 12 294 1213 386 1407 485 1566 325 1208 420 1399 522 1560 357 1201 455 1389 556 1550 0.8 0.9 1 388 1193 491 1377 591 1537 417 1185 526 1366 633 1528 443 1177 558 1357 - Indoor Blower Performance Indoor Fan Performance 4YCY4048A Horizontal Airflow 4YCY4048A-HOR Motor Speed LOW MED* HIGH External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 200 220 250 285 320 354 386 417 449 487 538 CFM 1407 1394 1396 1403 1408 1408 1402 1391 1380 1377 1392 Watts 268 316 354 386 417 448 483 520 559 597 630 CFM 1584 1608 1616 1615 1608 1600 1593 1586 1579 1568 1550 Watts 378 430 478 522 563 602 640 679 717 758 CFM 1798 1821 1830 1833 1831 1828 1825 1822 1817 1807 - Down Airflow 4YCY4048A-DOWN Motor Speed LOW MED* HIGH External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Watts 141 232 270 294 329 378 431 456 478 505 545 CFM 1344 1405 1414 1411 1416 1433 1425 1435 1430 1410 1400 Watts 253 332 379 412 443 480 524 570 607 619 583 CFM 1582 1614 1624 1624 1621 1618 1618 1620 1618 1606 1574 Watts 364 461 518 558 597 643 693 739 764 785 CFM 1816 1829 1836 1839 1840 1840 1844 1835 1830 1825 - Indoor Fan Performance 4YCY4060A Horizontal Airflow 4YCY4060A-HOR Motor Speed LOW MED* External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Watts 394 427 464 504 548 591 633 668 CFM 1673 1772 1799 1793 1779 1771 1767 1756 Watts 695 642 660 710 764 811 849 893 966 1108 CFM 2054 2036 2031 2032 2033 2031 2023 2012 2002 2000 1 - Down Airflow 4YCY4060A-DOWN Motor Speed LOW MED* Watts CFM Watts CFM External Static Pressure (in. wg) 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 443 461 493 532 571 607 642 680 1796 1741 1726 1725 1722 1712 1698 1692 740 697 715 763 819 866 892 894 872 835 2010 1987 1979 1977 1976 1969 1950 1913 1852 1759 *Factory Default Setting 13 1 - Indoor Blower Performance Heating Airflow, horizontal or downflow from .2 to .6” wg. 4YCY4024A1064 Selection Nominal Airflow Low Stage High Stage 8-OFF A 600 850 8-OFF B 625 900 8-ON C 650 925 8-ON D 700 975 Switch Settings 7-OFF 7-ON 7-OFF 7-ON Switch Settings 7-OFF 7-ON 7-OFF 7-ON 8-OFF 8-OFF 8-ON 8-ON 4YCY4030A Selection Nominal Airflow Low Stage High Stage A 725 1000 B 775 1075 C 850 1150 D 925 1250 4YCY4036A*075 Selection Switch Settings Nominal Airflow Low Stage High Stage 7-OFF 8-OFF A 725 1000 7-ON 8-OFF B 775 1075 7-OFF 8-ON C 850 1150 7-ON 8-ON D 925 1250 * can be 1 or 3 Switch Settings 7-OFF 7-ON 7-OFF 7-ON 8-OFF 8-OFF 8-ON 8-ON 4YCY4042A Selection Nominal Airflow Low Stage High Stage A 1075 1375 B 1100 1450 C 1150 1500 D 1200 1575 4YCY4048A*096 Selection Nominal Airflow Low Stage High Stage 8-OFF A 1075 1375 8-OFF B 1100 1450 8-ON C 1150 1500 8-ON D 1200 1575 * can be 1 or 3 Switch Settings 7-OFF 7-ON 7-OFF 7-ON 4YCY4048A*120 Selection Nominal Airflow Low Stage High Stage 8-OFF A 1050 1500 8-OFF B 1100 1575 8-ON C 1150 1625 8-ON D 1200 1700 * can be 1 or 3 Switch Settings 7-OFF 7-ON 7-OFF 7-ON 4YCY4060A 4YCY4036A*096 Selection Switch Settings Nominal Airflow Low Stage High Stage 7-OFF 8-OFF A 825 1100 7-ON 8-OFF B 875 1175 7-OFF 8-ON C 950 1275 7-ON 8-ON D 1025 1375 * can be 1 or 3 14 Switch Settings 7-OFF 7-ON 7-OFF 7-ON 8-OFF 8-OFF 8-ON 8-ON Selection A B C D Nominal Airflow Low Stage High Stage 1375 1800 1450 1900 1525 1975 1575 2075 Typical Field Wiring UNIT CONTROL BOX B G Y W1 W2 R GROUND WIRE COMMON FAN (GR) COMPRESSOR HEAT FIRST STAGE (WH) HEAT SECOND STAGE (WH) 24V 1 PH POWER 3 PH POWER UNIT NOTE 1 B G Y W1 W2 R COMMON FAN (GR) COMPRESSOR HEAT FIRST STAGE (WH) HEAT SECOND STAGE (WH) 24V B G (GR) Y W1 (WH) W2 (WH) R C 757192i2 15 Typical Wiring 16 Typical Wiring From Dwg. 21D757165 P02 17 Optional Equipment BAYCURB050A Full Perimeter Roof Mounting Curb for *****018-036A 17 7/8 46 3/8 3 3 5/8 19 1/2 2 3/16 19 1/2 15 38 7/8 14 1 1/2 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 43 3/8 35 7/8 18 Optional Equipment BAYCURB051A Full Perimeter Roof Mounting Curb for *****042-060A 15 7/8 56 1/8 3 1 1/2 10 7/8 19 1/2 20 4 3/4 19 1/2 41 7/8 14 The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 38 7/8 53 1/8 19 Optional Equipment BAYFLTR101, 201B, 1" - 2" Filter Rack (Mounts in Filter/Coil Section) Filter BAYACCDOR1A & BAYACCDOR2A Hinged Filter Access Door Replaces Filter/Coil Access Panel The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. 20 Optional Equipment BAYECON101,102A Down Discharge Economizer and Rain Hood (Mounts Over Horizontal Return Air Opening) HVAC Unit A Economizer rain hood Outside air dampers Required filter kit, order separately Return air dampers Economizer Unit ApplicationM odels A BAYECON101A 2/4YC,WC3018-036A 4TC*3018-036A 4W/T/Y/DCY4024-060 20.125" BAYECON102A 2/4YC,WC3042-060A 4TC*3042-060A 4W/T/Y/DCY4024-060 24.375" Mist eliminator Relief damper Roofcurb Return Duct BAYECON200,201A Horizontal Economizer and Rain Hood The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. A Economizer B D C Gaskets (2) Rain Hood E Duct Mixed Air Sensor Economizer A B C D E BAYECON200AA 22" 20" 16 7/8" 15 11/16 11 11/16 BAYECON201AA 24" 22 21/32" 19" 17 11/16 14 11/16 21 Optional Equipment BAYOSAH001,002A, 25% Outside Air Damper (Replaces Filter/Coil Access Panel) A The drawings on this page are prepared by the manufacturer in order to provide detail regarding job layout only. These drawings are not intended to be used as a basis to construct, build or modify the items depicted in the drawings. The manufacturer is not responsible for the unauthorized use of these drawings and expressly disclaims any liability for damages resulting from such unauthorized use. FULLY OPEN 2/3 1/3 C D FULLY CLOSED B Manual Fresh Air Model Unit Application Models A B C D BAYOSAH001 2/4YC,WC3018-036A 4TC*3018-036A 4W/T/Y/DCY4024-036A 4W/Y/DCZ6036A 22 7/16" 20 11/16" 12 3/8" 9 3/16" BAYOSAH002 2/4YC,WC3042-060A 4TC*3042-060A 4W/T/Y/DCY4042-060 4W/Y/DCZ6048-060A 25 3/16" 20 11/16" 12 3/8" 9 3/16" BAYDMPR101,102A, 25% Motorized Outside Air Damper (Mounts Over Horizontal Return AIr Opening) A C E Unit Application Models D A 2/4YC,WC3018-036A 4TC3018-036A BAYDMPR101A 15 13/16" 4W/T/Y/DCY4024-036A 4W/Y/DCZ6036A 2/4YC,WC3042-060A 4TC3042-060A BAYDMPR102A 18 3/16" 4W/T/Y/DCY4042-060A 4W/Y/DCZ6048-060A B C D E 11 13/16" 10 1/4" 11 1/2" 12 1/4" 15 1/8" 10 1/4" 11 1/2" 12 1/4" 22 B Dimensional Data 4YCY4024A through 4YCY4036A (1 of 3) 23 Dimensional Data 4YCY4024A through 4YCY4036A (2 of 3) 24 Dimensional Data 4YCY4024A through 4YCY4036A (3 of 3) 25 Dimensional Data 4YCY4042A through 4YCY4060A (1 of 3) 26 Dimensional Data 4YCY4042A through 4YCY4060A (2 of 3) 27 Dimensional Data 4YCY4042A through 4YCY4060A (3 of 3) 28 Mechanical Specifications General All units shall be factory assembled, piped, internally wired and fully charged with refrigerant. All units shall be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be rated in accordance with A.R.I. standards. The 4YCY4 heating/cooling unit design is UL listed, specifically for outdoor applications using natural gas or propane. All units shall be designed for outdoor rooftop or ground level installation. Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Shipped for horizontal application, convertible to downflow. Casings All panels shall be heavy gauge steel, gasketed and insulated. Foil-faced insulation shall be in the heat exchanger section. Foil-faced insulation shall be in the evaporator section. Base pan shall be heavy gauge steel. WEATHERGUARD™ exterior corrosion resistant screws shall be used for added resistance to rust and corrosion. Controls Refrigeration cycle controls shall include condenser fan, evaporator fan and compressor contactors. Compressors shall be equipped with a combination internal winding thermostat/current overload. Internal high pressure relief shall also be provided. Refrigeration System Compressors — The Climatuff® compressor features internal over temperature and pressure protector, total dipped hermetic motor. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise. Evaporator Coil — Internally enhanced 3/8-inch OD seamless copper tubing mechanically bonded to aluminum fins, factory pressure and leak tested at 250 to 300 psig. All units have TXV to control refrigeration flow. Trane 6200 Troup Highway Tyler, TX 75707-9010 Condenser Coil — The Spine Fin™ condenser coil shall be continuously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch OD seamless aluminum tubing glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Indoor Air Fan — Direct-drive, forwardcurved, centrifugal wheel in a Composite Vortica® Blower housing. Motor shall have thermal overload protection. Permanently lubricated motor bearings. Motor/blower assembly isolated from unit with rubber mounts. Condenser Fan — Direct-drive, draw through propeller type. Weather-proofed permanent split capacitor fan motor shall have built-in thermal overload and permanently lubricated motor bearings. Low Ambient — Standard refrigerant system operation down to 55°F. Low ambient accessory required for operation to 0°F ambient condition. Gas-Fired Heating System — Models shall provide completely assembled, wired and piped gas fired heating systems within unit. Design certified by UL, specifically for outdoor application. Threaded gas connection on the unit. Electronic Ignition System — Main burner is lit each time thermostat calls for gas heat. Flame sensor proves flame and keeps the main burners on. Should a loss of flame occur, the main valve closes and the spark recurs within 0.8 second. When thermostat is satisfied, main burner is extinguished. Forced Combustion Blower — Insures flame stability under varying wind conditions. Gives higher combustion efficiency and location flexibility. Heat Exchanger — stainless steel tubes. Free floating design. Burners — stainless steel. Multiport inshot. Accessories (U.S. Domestic Models) Roof Curb — The roof curb shall be designed to mate with the unit and provide support and complete weather-tight installation when properly installed. Curb shall ship knocked down for field assembly, and include wood nailer strips. Modulating Economizer — This accessory shall be field installed and be composed of the following items: 0-100% fresh air damper, damper drive motor fixed dry bulb enthalpy control, and low voltage polarized plug for electrical connections. Solid state enthalpy or differential enthalpy control is optional. Economizer operations shall be controlled by the preset position of the enthalpy control. A barometic relief damper shall be standard with the economizer and provide a pressure operated damper that shall be gravity closing and prohibit entrance of outside air on equipment “off” cycle. Manual Fresh Air Hood Manual outside air provides a fixed outside air quantity from 0 to 25 percent. Includes hood and birdscreen. Low Ambient Control Control allows cycling of compressor under low ambient cooling conditions. Required for cooling operation to 0°F. Propane Gas Conversion Kit — For conversion from natural gas to LP gas. The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. 29
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 29 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e28f240b-6d5e-4977-baeb-5b99eff22ab6 Producer : Acrobat Distiller 8.1.0 (Windows) Acces flag : F Alt order nbr : Alt order nbr type : Bw color : B Date published : 05/01/2008 Dept id : 54 Topic focused id : EN|TRANE Price : 0 Cur flag : T Lit class id : SV Lit length : 29 Lit order nbr : 22-1797-03 Lit type id : PRD Media id : NON Model : YCY Prod class : UN Prod family id : 2000205 Prod : RT Restrct flag : F Source date : nulldate Source filename : Stocking loc id : None Supceded by : Supceded by date : 05/01/2008 Unit flag : T Branding : Trane Lol language : EN Object id : 090102b18119837d Object name : 22-1797-03_05012008 Chronicle id : 090102b18119837d Filename : 8119837d.pdf Abstract : Features and Benefits, Model Number Description, General Data, Ratings with Auxiliary Devices, Performance Data Cooling, Performance Data Heating, Typical Wiring, Dimensional Data Hist model : 4YCY4024|4YCY4030A1064A|4YCY4030A1075AA|4YCY4036|4YCY4042|4YCY4048|4YCY4060 Topic related id : TRN-FLD|SYS-DSN|STARTUP|SERVICER|SERV|RRR|OPER|INST|DSGN|AMSTD Creator Tool : PageMaker 7.0 Modify Date : 2008:08:14 16:04:27-05:00 Create Date : 2008:05:28 14:46:50-05:00 Metadata Date : 2008:08:14 16:04:27-05:00 Document ID : uuid:2346d6c4-9e84-4cdf-862c-f836ad6c8ac8 Instance ID : uuid:991dca91-fa25-4ec6-add5-c9615b27b452 N Pages : 29 Format : application/pdf Title : 22-1797-03 05/01/2008 Trane Product Data 14 SEER Single Packaged Convertible Gas/Electric, 2 - 5 Ton, 40 - 120 KBTU, R-410A Models 4YCY4024A through 4YCY4060A Creator : tyajn Author : tyajn Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : B Hist Model : 4YCY4024A1040AA|4YCY4024A1064A|4YCY4030A1064A|4YCY4024|4YCY4036|4YCY4036A1064A|4YCY4036A1075A|4YCY4036A1096A|4YCY4036A3075A|4YCY4036A3096A|4YCY4042|4YCY4042A1064A|4YCY4048|4YCY4048A1064A|4YCY4048A1096A|4YCY4048A1120A|4YCY4048A3096A|4YCY4048A3120A|4YCY4060|4YCY4060A1064A|4YCY4060A1120A|4YCY4060A3120A Date Published : 05/01/2008 Dept Id : 54 Topic Focused Id : TRANE|EN Cur Flag : T Lit Class Id : PL Lit Length : 29 Lit Order Nbr : 22-1797-03 Lit Type Id : PRD Media Id : ELO Prod Class : UN Prod Family Id : 2004935 Topic Related Id : TRN-FLD|SYS-DSN|STARTUP|RRR|OWN/DEV|OPER|INST|DSGN Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : None Supceded By : Supceded By Date : nulldate Unit Flag : T Lol Language : EN Object Id : 090102b18118c5b7 Object Name : 22-1797-03_05012008 Chronicle Id : 090102b1805c89b3EXIF Metadata provided by EXIF.tools