Trane Odyssey 6 To 25 Tons Catalogue R22 Dry Charge Product Catalog For Cooling Condenser — 7.5, 10, 15 And 20 60 Hz
2015-04-02
: Trane Trane-Odyssey-6-To-25-Tons-Catalogue-684219 trane-odyssey-6-to-25-tons-catalogue-684219 trane pdf
Open the PDF directly: View PDF .
Page Count: 16
Download | |
Open PDF In Browser | View PDF |
Product Catalog Split System Air Conditioners Odyssey™ ™ R-22 Dry Charge Cooling Condenser — 7.5, 10, 15 and 20 Tons — 60 Hz May 2014 SS-PRC037C-EN Introduction Trane’s reputation for providing quality comfort solutions continues with the development of the next generation Light Commercial Odyssey Split Systems. With wide network availability, flexible applications, installation ease, built-in reliability and easy servicing, Odyssey will meet any number of customer applications. Add to that Trane’s outstanding customer service and you have the formula to make Odyssey the clear choice for continued customer satisfaction. Wide network availability A broad distribution network provides owners, maintenance personnel, contractors, etc., the means to get their hands on equipment when they need it. Whether it’s an emergency replacement or a new construction project in its infancy stages, Odyssey products meet an array of needs at the right time and right price. Flexible applications No matter what the application, Odyssey provides the solution. A broad array of models and tonnages are available with single or dual compressors, single or dual circuits and numerous accessories. Condensing units can be installed on the ground or on a rooftop along with extended piping runs, while air handlers can be free discharge on the ground or horizontally suspended with long duct runs from a ceiling. Should application challenges arise, Odyssey delivers. Easy to install Small footprints and low weights combined with factory installed components like TXVs, filter driers, etc., reduce installation time and cost. Colored and numbered wiring and factory tested units make Odyssey the right choice. Built-in reliability Keeping in mind that productivity only occurs when equipment is operational,Trane has taken the steps to ensure that Odyssey is up and running. Early indicators such as phase/reversal monitors and loss of charge protection provide diagnostics which prevent failure and provide years of worry-free service and operation. ©2014 Trane All rights reserved SS-PRC037C-EN Introduction Easy to service When preventive maintenance or service is required, technicians will find efficient access to both air handlers and condensers. Panels provide complete, easy access coupled with standardized cabinets in which all components are located in proximity. Odyssey’s improved design results in minimum service times and costs. With these capabilities, Odyssey provides customers high efficiency and superior performance for the best all-around value in the market today. Copyright This document and the information in it are the property of Trane, and may not be used or reproduced in whole or in part without written permission. Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. Trademarks All trademarks referenced in this document are the trademarks of their respective owners. SS-PRC037C-EN 3 Table of Contents Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Cooling Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Model Number Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Cooling Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 General Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Dimensional Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Cooling Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Weights. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Cooling Condenser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 4 SS-PRC037C-EN Accessories Cooling Condenser Table 1. TTA Accessories Model Used With Coil (Hail/Vandal) Guard BAYGARD058A TTA090A BAYGARD059A TTA120A BAYGARD061A TTA180B, TTA240B BAYHGBP010B All models Rubber Isolators BAYISLT004A (blue) TTA090A BAYISLT005A (black) TTA120A BAYISLT009A (red) TTA180B BAYISLT010A (green) TTA240B Steel Spring Isolators BAYISLT023A (red) TTA090A, TTA120A BAYISLT024A (black) TTA180B BAYISLT025A (yellow) TTA240B Low Ambient — On/Off Fan Control (External mount, small cabinets)(a) (b) (c) BAYLOAMU01B (External Mount, small cabinets)(d) BAYLOAMU02B (Internal mount, large cabinets) (a) (b) (c) (d) (all voltages) TTA090A (all voltages) TTA120A, TTA180B, TTA240B Cycles fan on/off, (no modulating). Quantity of 1 required for each fan (2 total for ). ReliaTel™ requires onboard EDC function to be disabled when BAYLOAM is used, remove OA sensor from terminal J8-1&2 Kit mounts external to the outdoor unit and operates by sensing ambient and liquid line temperatures. SS-PRC037C-EN 5 Model Number Description Cooling Condenser TTA 120 A 3 00 * * 123 456 7 8 9 10 11 12 All products are identified by a multiple-character model number that precisely identifies a particular type of unit. An explanation of the alphanumeric identification code is provided. Its use will enable the owner/operator, installing contractors, and service engineers to define the operation, specific components, and other options for any specific unit. When ordering replacement parts or requesting service, be sure to refer to the specific model number, serial number, and DL number (if applicable) stamped on the unit nameplate. D I G I T S 1 - 3 : P r o d u c t Ty p e TTA = Split System Cooling DIGITS 4 - 6: Nominal Gross Cooling Capacity (MBh) 090 = 7.5 Tons (60Hz) 120 = 10 Tons (60Hz) 180 = 15 Tons (60Hz) 240 = 20 Tons (60Hz) DIGIT 7: Major Develop men t Sequence A = Single Compressor, Single Circuit, R-22 B = Dual Compressor, Dual Circuit, R-22 DIGIT 8: Electrical Characteristics 3 = 208–230/60/3 4 = 460/60/3 D I G I T S 9 - 10 : F a c t o r y I n s t a l l e d O p t i o n s 00 = Packed Stock D I G I T S 11 : M i n o r D e s i g n S e q u e n c e * = Current Design Sequence1 D I GI TS 12 : Serv i c e D ig it * = Current Design Sequence1 1. 6 * = sequential alpha character SS-PRC037C-EN General Data Table 2. General Data – 7.5 to 20 ton 7.5 Tons 10 Tons 15 Tons Single Compressor Single Compressor Dual Compressor TTA090A3, A4 TTA120A3, A4 TTA180B3, B4 20 Tons Dual Compressor TTA240B3, B4 Compressor Type Scroll Scroll Scroll Scroll No./Tons 1/6.9 1/8.6 2/6.9 2/8.6 System Data No. Refrigerant Circuits 1 1 2 2 Suction Line (in.) OD 1.38 1.38 1.38 1.38 Liquid Line (in.) OD 5/8 1/2 1/2 1/2 Outdoor Coil Type Lanced Lanced Lanced Lanced Tube Size (in.) OD 0.38 0.38 0.38 0.38 Face Area (sq ft) 19.2 24.0 24.0 24.0 Rows/FPI (Fins per inch) 2/18 2/18 2/18 2/18 Propeller Propeller Propeller Propeller 1/26 1/28 2/28 2/28 Direct/1 Direct/1 Direct/1 Direct/1 19500 Outdoor Fan Type No. Used/Diameter (in.) Drive Type/No. Speeds CFM 6530 9600 19500 No. Motor/HP 1/0.5 1/1 2/1 2/1 Motor RPM Refrigerant Charge (Field Supplied) 1100 1100 1100 1100 lbs of R-22 17.6 22.5 39.0 43.8 43.54” x 43” x 36.5” 43.5” x 53” x 40.5” 49.5" x 94.8" x 47" 49.5" x 94.8" x 47" Shipping Dimensions HxWxD (in.) SS-PRC037C-EN 7 Performance Data Table 3. Gross cooling capacities (MBH) 7.5 tons TTA090A condensing unit only (IP) Suction Temperature (°F) Outdoor Temp (°F) 65 75 85 95 105 115 125 30 35 40 45 50 55 Head Press (psig) 161.3 172.4 178.7 185.3 192.4 199.8 Capacity (Btuh/1000) 76.9 84.9 93.7 102.9 112.5 122.3 Unit Power (kW) 4.9 5.0 5.2 5.3 5.5 5.7 Head Press (psig) 190.9 197.1 203.6 210.4 217.7 225.4 Capacity (Btuh/1000) 73.0 81.0 89.4 98.1 107.2 116.6 Unit Power (kW) 5.3 5.5 5.7 5.8 6.0 6.2 Head Press (psig) 217.8 224.3 231.1 238.3 246.0 254.0 Capacity (Btuh/1000) 69.4 77.0 85.0 93.3 102.0 110.9 Unit Power (kW) 5.9 6.0 6.2 6.4 6.6 6.8 Head Press (psig) 247.6 254.3 261.5 269.0 276.9 285.2 Capacity (Btuh/1000) 65.7 73.0 80.6 88.5 96.7 105.2 Unit Power (kW) 6.4 6.6 6.8 7.0 7.2 7.4 Head Press (psig) 280.1 287.1 294.6 302.4 310.6 319.1 Capacity (Btuh/1000) 61.9 68.9 76.1 83.7 91.5 99.5 Unit Power (kW) 7.1 7.3 7.5 7.7 7.9 8.1 Head Press (psig) 315.3 322.7 330.5 338.6 347.1 355.9 Capacity (Btuh/1000) 58.1 64.7 71.6 78.8 86.2 93.8 Unit Power (kW) 7.8 7.9 8.1 8.3 8.6 8.8 Head Press (psig) 353.4 361.2 369.3 377.7 386.4 395.4 Capacity (Btuh/1000) 54.2 60.5 67.1 73.9 80.9 88.1 Unit Power (kW) 8.5 8.7 8.9 9.1 9.3 9.5 Note: Performance data calculated at 15°F subcooling and 15°F superheat and does not include capacity loss due to refrigerant lines. Figure 1. TTA090A capacity curves Capacity Curves - Condensing Unit Only COMPRESSOR HIGH SUCTION LIMIT 135 INDOOR COIL FROST LIMIT Gross Cooling Capacity (MBH) 120 105 90 75 65 75 85 95 105 115 125 60 45 25 30 35 40 45 50 55 60 Sa turated Suction Temperature (F) 8 SS-PRC037C-EN Pe r f o r m a n c e D a t a Table 4. Gross cooling capacities (MBH) 10 tons TTA120A condensing unit only (IP) Suction Temperature (°F) Outdoor Temp (°F) 65 75 85 95 105 115 125 30 35 40 45 50 55 Head Press (psig) 161.5 166.6 172.0 177.9 184.0 190.6 Capacity (Btuh/1000) 98.2 108.8 120.0 131.8 144.0 157.0 Unit Power (kW) 7.1 7.3 7.5 7.8 8.0 8.2 Head Press (psig) 185.0 190.2 195.9 201.8 208.2 215.0 Capacity (Btuh/1000) 94.1 104.2 115.1 126.5 138.4 150.9 Unit Power (kW) 7.6 7.8 8.0 8.2 8.5 8.7 Head Press (psig) 210.8 216.2 222.0 228.3 234.9 241.9 Capacity (Btuh/1000) 89.6 99.4 109.8 120.8 132.3 144.3 Unit Power (kW) 8.2 8.4 8.6 8.8 9.1 9.3 Head Press (psig) 239.3 245.0 251.0 257.4 264.2 271.4 Capacity (Btuh/1000) 84.8 94.2 104.2 114.7 125.8 137.3 Unit Power (kW) 8.9 9.1 9.3 9.5 9.7 10.0 Head Press (psig) 270.5 276.4 282.6 289.2 296.2 303.6 Capacity (Btuh/1000) 79.7 88.8 98.3 108.3 118.9 129.9 Unit Power (kW) 9.6 9.9 10.1 10.3 10.5 10.7 Head Press (psig) 304.3 310.4 316.8 323.6 330.7 338.3 Capacity (Btuh/1000) 74.4 83.0 92.1 101.6 111.6 122.1 Unit Power (kW) 10.5 10.7 10.9 11.1 11.4 11.6 Head Press (psig) 340.9 347.2 353.8 360.7 368.0 375.7 Capacity (Btuh/1000) 68.9 77.0 85.6 94.6 104.0 113.9 Unit Power (kW) 11.4 11.6 11.9 12.1 12.3 12.5 Note: Performance data calculated at 15°F subcooling and 15°F superheat and does not include capacity loss due to refrigerant lines. Figure 2. TTA120A capacity curves Capacity Curves - Condensing Unit Only 175 COMPRESSOR HIGH SUCTION LIMIT 160 INDOOR COIL FROST LIMIT Gross Cooling Capacity (MBH) 145 130 115 100 65 75 85 95 105 115 125 85 70 55 25 30 35 40 45 50 55 60 Sa turated Suction Temperature (F) SS-PRC037C-EN 9 Pe r f o r m a n c e D a t a Table 5. Gross cooling capacities (MBH) 15 tons TTA180B condensing unit only (IP) Suction Temperature (°F) Outdoor Temp (°F) 65 75 85 95 105 115 125 30 35 40 45 50 55 Head Press (psig) 147.1 151.0 155.3 159.8 164.5 169.6 Capacity (Btuh/1000) 151.2 169.1 188.5 208.9 230.0 252.5 Unit Power (kW) 10.1 10.3 10.5 10.7 10.9 11.1 Head Press (psig) 169.9 174.0 178.3 182.9 187.8 192.9 Capacity (Btuh/1000) 143.8 160.9 179.2 198.7 219.1 240.4 Unit Power (kW) 10.9 11.1 11.4 11.6 11.9 12.1 Head Press (psig) 195.2 199.4 203.8 208.5 213.5 218.7 Capacity (Btuh/1000) 136.3 152.6 169.9 188.4 207.9 228.2 Unit Power (kW) 11.9 12.1 12.4 12.6 12.9 13.2 Head Press (psig) 223.1 227.5 232.0 236.9 242.0 247.4 Capacity (Btuh/1000) 128.6 144.2 160.7 178.1 196.7 216.0 Unit Power (kW) 12.9 13.2 13.5 13.7 14.1 14.4 Head Press (psig) 253.8 258.3 263.1 268.1 273.3 278.9 Capacity (Btuh/1000) 120.7 135.6 151.4 167.9 185.4 203.8 Unit Power (kW) 14.1 14.4 14.7 15.0 15.3 15.6 Head Press (psig) 287.3 292.0 296.9 302.0 307.4 313.1 Capacity (Btuh/1000) 112.8 127.0 141.9 157.7 174.2 191.5 Unit Power (kW) 15.4 15.7 15.9 16.2 16.6 16.9 Head Press (psig) 323.7 328.6 333.6 338.9 344.4 350.1 Capacity (Btuh/1000) 104.7 118.2 132.4 147.3 162.9 179.1 Unit Power (kW) 16.8 17.0 17.3 17.6 17.9 18.3 Note: Performance data calculated at 15°F subcooling and 15°F superheat and does not include capacity loss due to refrigerant lines. Figure 3. TTA180B capacity curves Capacity Curves - Condensing Unit Only 290 COMPRESSOR HIGH SUCTION LIMIT 275 260 230 INDOOR COIL FROST LIMIT Gross Cooling Capacity (MBH) 245 215 200 185 170 155 65 75 85 95 105 115 125 140 125 110 95 80 25 30 35 40 45 50 55 60 Sa turated Suction Temperature (F) 10 SS-PRC037C-EN Pe r f o r m a n c e D a t a Table 6. Gross cooling capacities (MBH) 20 tons TTA240B condensing unit only (IP) Suction Temperature (°F) Outdoor Temp (°F) 65 75 85 95 105 115 125 30 35 40 45 50 55 Head Press (psig) 161.1 166.0 171.2 176.7 182.6 188.8 Capacity (Btuh/1000) 203.6 224.1 245.9 268.8 293.0 318.3 Unit Power (kW) 14.2 14.6 15.1 15.5 16.0 16.5 Head Press (psig) 185.1 190.2 195.6 201.4 207.4 213.8 Capacity (Btuh/1000) 196.0 215.9 237.1 259.4 282.8 307.3 Unit Power (kW) 15.3 15.7 16.1 16.5 17.0 17.5 Head Press (psig) 211.4 216.8 222.5 228.5 234.9 241.6 Capacity (Btuh/1000) 187.5 206.9 227.3 248.9 271.6 295.3 Unit Power (kW) 16.5 16.9 17.3 17.7 18.2 18.7 Head Press (psig) 240.6 246.2 252.1 258.4 265.0 271.9 Capacity (Btuh/1000) 178.5 197.1 216.8 237.6 259.4 282.2 Unit Power (kW) 17.9 18.3 18.7 19.1 19.6 20.0 Head Press (psig) 272.3 278.2 284.4 290.9 297.7 304.9 Capacity (Btuh/1000) 168.7 186.6 205.5 225.4 246.3 268.2 Unit Power (kW) 19.5 19.9 20.3 20.7 21.1 21.6 Head Press (psig) 306.8 312.9 319.3 326.0 333.1 340.4 Capacity (Btuh/1000) 158.5 175.5 193.5 212.5 232.5 253.3 Unit Power (kW) 21.2 21.6 22.0 22.4 22.9 23.3 Head Press (psig) 344.0 350.3 356.9 363.9 371.1 378.7 Capacity (Btuh/1000) 147.8 163.9 181.0 199.0 217.9 237.7 Unit Power (kW) 23.1 23.5 23.9 24.4 24.8 25.2 Note: Performance data calculated at 15°F subcooling and 15°F superheat and does not include capacity loss due to refrigerant lines. Figure 4. TTA240B capacity curves Capacity Curves - Condensing Unit Only 350 335 COMPRESSOR HIGH SUCTION LIMIT 320 290 INDOOR COIL FROST LIMIT Gross Cooling Capacity (MBH) 305 275 260 245 230 215 200 65 75 85 95 105 115 125 185 170 155 140 125 25 30 35 40 45 50 55 60 Sa turated Suction Temperature (F) SS-PRC037C-EN 11 Electrical Data Table 7. Electrical characteristics — compressor and condenser fan motors — 60 Hz Compressor Motor Unit Model Tons Number 7.5 10 15 20 Condenser Fan Motor Amps No. Volts Phase RLA LRA (Ea.) (Ea.) Amps No. Volts Phase FLA LRA (Ea.) (Ea.) TTA090A3 1 208-230 3 22.4 164 1 208-230 1 3.1 8.1 TTA090A4 1 460 3 10.9 100 1 460 1 1.6 3.8 TTA120A3 1 208-230 3 30.1 225 1 208-230 1 5.0 14.4 TTA120A4 1 460 3 15.5 114 1 460 1 2.5 5.8 TTA180B3 2 208-230 3 22.4 164 2 208-230 2 5.0 14.4 TTA180B4 2 460 3 10.9 100 2 460 2 2.5 5.8 TTA240B3 2 208-230 3 30.1 225 2 208-230 2 5.0 14.4 TTA240B4 2 460 3 15.5 114 2 460 2 2.5 5.8 Note: Electrical characteristics reflect nameplate values and are calculated in accordance with cULus and ARI specifications. Table 8. Tons Unit wiring — condensing units — 60 Hz Unit Model Number Unit Operating Voltage Range Minimum Circuit Ampacity Maximum Fuse or HACR Circuit Breaker Size 45 TTA090A3 187-253 31.1 TTA090A4 414-506 15.2 25 10 TTA120A3 187-253 42.6 60 TTA120A4 414-506 21.9 30 15 TTA180B3 187-253 60.4 80 TTA180B4 414-506 29.5 40 TTA240B3 187-253 77.7 100 TTA240B4 414-506 39.9 50 7.5 20 Note: HACR type circuit breaker per NEC. 12 SS-PRC037C-EN Dimensional Data Cooling Condenser Figure 5. 7.5 ton condensing unit, single compressor SEE NOTE 3 NOTES : 1. ACCES S OP ENING IS FOR FIELD INS TALLED BAYLOAM ACCES S ORY. 2. MINIMUM CLEARANCE FOR P ROP ER OP ERATION IS 36" (914.4) FROM W ALLS , S HRUBBERY, P RIVACY FENCES ETC. MINIMUM CLEARANCE B ETWEEN ADJ ACENT UNITS IS 72" (1828.8). RECOMMENDED S ERVICE C LEARANCE 48" (1219. 2) 3. TOP DIS CHARGE AREA S HOULD BE UNRES TRICTED FOR 100" (2540) MINIMUM. UNIT S HOULD BE P LACED S O ROOF RUN-OFF WATER DOES NOT P OUR DIRECTLY ON UNIT 4. OUTDOOR AIR TEMP ERATURE S ENS OR OP ENING (DO NOT BLOCK OP ENING) SERVICE PANEL SEE NOTE 4 HAIL GUARD (OP TIONAL) S ERVICE CLEARANCE 48" (1219.2) (S EE NOTE 2 FOR CLEARANCE) HAIL GUARD (OP TIONAL) S EE NOTE 1 35 15/1 6" (912 .8) WITH HAIL GUARD 33 7/8" (86 0.4) LINE VOLTAGE CONT ROL WIRING REFRIGERANT ACCES S 39 3/16" (995.3) SER VICE P ANEL 34 1/8" (866.8) 26 15/16" (684.2) 29 13/16" (757.2) 16 7/16" (417.5) 14 3/8" (365.1) 1/16" (1.59) 7 15/16" (201.6) 6" (152.4) 6" (152.4) SUCTION LINE 1 7/8" (47.6) 21 11 /16" (55 0.9) LIQUID LINE 2 7/8" (73) 33 13/1 6" (858 .8) 40 15/16" (1039.8) 41 15/16" (1065. 2) WITH HAIL GUARD SERVIC E P ANEL S IDE 3" (76. 2) 40 3/4" (1035) 34 3/4" (882.6) 7/16" (11.11) DIA. IS OLATOR MOUNTING HOLES (OUTS IDE HOLES - 4 P LACES ) BOTTOM OF UNIT 4 3/16" (106.36) 1 13/16" (46) SS-PRC037C-EN 27 11/ 16" (703.3 ) 2 5/16" (58.7) 13 Dimensional Data Figure 6. 10 ton condensing unit, single compressor SEE NOTE 3 NOTES : 1. ACCES S OP ENING IS FOR FIELD INS TALLED BAYLOAM ACCES S ORY. 2. MINIMUM CLEARANCE FOR P ROP ER OP ERATION IS 36" (914.4) FROM WALLS , S HRUBBERY, P RIVACY FENCES ETC. MINIMUM CLEARANCE B ETWEEN ADJ ACENT UNITS IS 72" (1828.8). RECOMMENDED S ERVICE C LEARANCE 48" (1219.2) 3. TOP DIS CHARGE AREA S HOULD BE UNRES TRICTED FOR 100" (2540) MINIMUM. UNIT S HOULD BE P LACED S O ROOF RUN-OFF WATER DOES NOT P OUR DIRECTLY ON UNIT 4. OUTDOOR AIR TEMP ERATURE S ENS OR OP ENING (DO NOT BLOCK OP ENING) SERVICE PANEL HAIL GUARD (OP TIONAL) SEE NOTE 4 S ERVICE CLEARANCE 48" (1219.2) (S EE NOTE 2 FOR CLEARANCE S EE NOTE 1 4 1/4" (108) HAIL GUARD (OP TIONAL) 39 15 /16" (1014 .4) WITH HAIL GUARD 1 1/4" (31.7) REFRIGERANT ACCES S 37 15/1 6" (963 .6) LINE VOLTAGE CONTROL WIRING 39 1/8" (993.8) SER VICE P ANEL 34 1/16" (865.2) 29 3/4" (755.6) 26 7/8" (682.6) 14 5/16" (363.5) 7 1/2" 8 1/4" (190.5) (209.5) 1/16" (1.6) SUCTION LINE 25 11/1 6" (652 .5) 6" (152. 4) 1 15/16" (49.2) LIQUID LINE 4 15/16" (125.4) 6" (152. 4) 1 7/8" (47.6) 2 7/8" (73) 50 15/16" (1294) 51 15/16" (1319.2) WITH HAIL GUARD 37 11/1 6" (957 .3) SERVICE P ANEL S IDE 7/16" (11.1) DIA. IS OLATOR MOUNTING HOLES (OUTS IDE HOLES - 4 P LACES ) 3" (76. 2) 50 3/4" (1289) 44 3/4" (1136.6) BOTTOM OF UNIT 3 13/16" (96.8) 2 3/16" (55.6) 14 31 11/1 6" (804.9) 1 11/16" (42.9) SS-PRC037C-EN Dimensional Data Figure 7. 15-20 ton condensing unit, dual compressor SEE NOTE 2 NOTES : 1. MINIMUM CLEARANCE FOR P ROP ER OP ERATION IS 36" (914.4) FROM WALLS , S HRUBBERY, P RIVACY FENCES ETC. MINIMUM CLEARANCE B ETWEEN ADJ ACENT UNITS IS 72" (1828.8). RECOMMENDED S ERVICE C LEARANCE 48" (1219.2) 2. TOP DIS CHARGE AREA S HOULD BE UNRES TRICTED FOR 100" (2540) MINIMUM. UNIT S HOULD BE P LACED S O ROOF RUN-OFF WATER DOES NOT P OUR DIRECTLY ON UNIT 3. OUTDOOR AIR TEMP ERATURE S ENS OR OP ENING (DO NOT BLOCK OP ENING) HAIL GUARD (OP TIONAL) SEE NOTE 3 S ERVICE CLEARANCE 48" (1219.2) (S EE NOTE 1 FOR CLEARANCE) SERVICE PANEL DETAIL A 46" (1168.4) WITH HAIL GUARD 95 7/16" (2424) WITH HAIL GUARD 41 7/16" (1052.5) 44" (1117. 6) HAIL GUARD (OP TIONAL) HAIL GUARD (OP TIONAL) 45 1/8" (1146.2) SER VICE P ANEL 3 3/8" (85.7) 6 5/8" (168.3) 1/16" (1.6) 3/16" (4.8) 41 3/8" (1051) 9" (228.6) 93 5/16" (2370.1) 25 11/16" (652.5) 9" (228. 6) 9 1/4" (235) 6 13/16" (173) 1 3/16" (30.2) 7/16" (11.1) DIA. ISOLATOR MOUNTING HOLES (OUTS IDE HOLES - 4 P LACES ) LINE VOLTAGE CONTROL WIRING SERVICE PANEL SIDE S UCTION LINE REFRIGERANT ACCES S 39 7/8" (1012.8) BOTTOM OF UNIT 36 7/8" (936.6) 3" (76. 2) 87" (2210) 93" (2362.2) 2 3/16" 6 13/16" (55.6) (173) 41 1/ 2" (105 4) 41 5/8" (1057.3) 18 3/4" (476.2) 14 5/8" (371.5) 12 9/16" (319.1) 5 9/16" 4 3/8" (141.3) (111.1) S UCTION LINE LIQUID LINES 6 5/16" (160.3) 3 11/16" (93.7) 15/16" (23.8) FRO NT DETAIL A DIMENS IONAL DETAIL SS-PRC037C-EN 15 Weights Cooling Condenser Table 9. TTA unit and corner weights — lbs (60 Hz) Tons Model No. Shipping Max (lbs) Net Max (lbs) 7.5 TTA090A 363 10 TTA120A 15 TTA180B 20 TTA240B Corner Weights 1 2 3 4 298 84 89 44 81 467 395 133 103 70 89 850 723 207 204 151 161 970 837 262 240 164 171 Figure 9. TTA180B, 240B Figure 8. TTA090A, 120A #4 #3 #4 #1 #1 #3 #2 S ER AC C VIC E ES S #2 S ER AC C VIC E ES S S ER AC C VIC E ES S LIFTING HOLES (BOTH S IDES ) LIFTING HOLES (BOTH S IDES ) Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane All rights reserved SS-PRC037C-EN 19 May 2014 We are committed to using environmentally Supersedes SS-PRC037-EN (July 2012) conscious print practices that reduce waste.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Instance ID : uuid:77a0b494-a765-47fc-ba51-cf9018a2e14f Document ID : uuid:16D9A8FF-DCE3-FF32-897F-C2898FDAEFA9 Modify Date : 2014:08:18 12:13:17-05:00 Metadata Date : 2014:08:18 12:13:17-05:00 Create Date : 2014:05:19 15:04:40-05:00 Creator Tool : Arbortext Editor with Styler Producer : PDFlib+PDI 8.0.5p2 (C++/Win32) Keywords : TTA; R-22; R-22 dry charge; Odyssey Prod : Hist model : Cur flag : Date published : 19 May 2014 Lit order nbr : SS-PRC037C Config File : C:\Users\lahhf\Documents\Arbortext\Projects\Eclipse_Workspace\CCMS_DEVELOPMENT\Arbortext_PE_6.0\app\low-res.3sppdf Stylesheet : C:\Users\lahhf\Documents\Arbortext\Projects\Eclipse_Workspace\CCMS_DEVELOPMENT\Arbortext_PE_6.0\application\com.ingersollrand.sma\doctypes\servicemanual\servicemanual.style PTC Arbortext Build : R60M110-1031 EP Sprocessor : PStill version 1.78.16 Print Engine : Arbortext Advanced Print Publisher 11.0.3157/W Library Marked : True Startup Profile : Print Format : application/pdf Title : Odyssey R22 Dry Charge Product Catalog for Cooling Condenser — 7.5, 10, 15 and 20 Tons — 60 Hz Subject : TTA, R-22, R-22 dry charge, Odyssey Rights : ©2014 Trane All rights reserved. Page Layout : SinglePage Page Count : 16 Creator : Arbortext Editor with Styler Cur Flag : Date Published : 19 May 2014 Hist Model : Lit Order Nbr : SS-PRC037CEXIF Metadata provided by EXIF.tools