Vertical Self-Contained Air Conditioning Air and Water Cooled 5 - 15 Tons 60 Hz PKG-PRC007-EN Introduction The TRANE Company, a world leader in the HVAC industry, has developed another option to meet the needs of our customers . . . the Genius! Built to provide not only the indoor comfort but also the confidence that the unit is reliable, durable, easy to install and maintain. The Genius line has been designed to satisfy the demands of the international markets. IAQ standards, microcontrols and simplified maintenance were all considered during its design. Water Cooled Unit ©American Standard Inc. 2000 PKG-PRC007-EN Contents PKG-PRC007-EN Introduction 2 Features and Benefits 4 Model Number Description 8 General Data 9 Selection Procedure 10 Performance Data 11 Controls 36 Electrical Data 37 Dimensions 47 Mechanical Specification 51 3 Features and Benefits The Genius line was built to provide not only ultimate indoor comfort but also the comfort of knowing that our selfcontained units are reliable as well as easy to install and maintain. Micro Controls Trane was the first to introduce Microelectronics to commercial unitary products and has continued to expand its application to other products. Genius is the most flexible vertical selfcontained of the market. Suitable to use in offices, residences or restaurants. Available as water cooled, integrated air cooled (or package unit) or with remote air coded condenser; the modern design of the Genius line allows you, for the first time, to select the color of the unit. The new self-contained with Micro provides the highest performance, reliability and best serviceability in the industry. Trane, a world class manufacturer can provide this winning combination for your facility. The Trane Micro, provided as a factory installed option, was designed with two thoughts in mind: reliability and comfort. The Micro accurately orchestrates all other system operations whether it is heating or cooling. Why Consider Self-Contained Floor-by-Floor Systems? Improved Cash Management • Factory installed options and testing: Reduces field labor and installation risk and improves system reliability • Requires less sophisticated maintenance than built-up systems Since it is factory mounted it will provide smooth, trouble-free start-up. SRVE (with discharge plenum) Tenant Satisfaction • Complete HVAC system on each floor or area minimizes tenant inconvenience during routine maintenance. • Tenants can control system after hours to increase productivity and minimize expense Low First Cost • Factory packaged controls and piping reduce field labor, installation time and cost • Flexible arrangement to match most building configurations Lower Installed Cost • Single point power connection • Single point water connection • Factory commissioned and tested controls • Factory installed options 4 Economical Operation • Floor-by-floor system results in energy savings since only air conditioners on floors requiring cooling need to operate • Annual system energy consumption comparable to central chilled water system but with significant energy consumption reduction during partial occupancy and after-hours The microprocessor provides powerful operation and diagnostic information. The micro eliminates the need for a field installed anti short-cycle timer and time delay relays, which are an integral part of the micro controller. The IAQ standard, the microelectronics and the simplified maintenance capability were all considered a priority during the design phase of this selfcontained unit. Assured Acoustical Performance • Horizontal discharge plenum provides smooth airflow, reducing static pressure losses for optimum acoustical performance. • Scroll compressor design smooths gas flow for quieter operation PKG-PRC007-EN Features and Benefits Air Handling Section In accordance to the ASHRAE Standard 62-89 for Indoor Air Quality, Trane has developed an exclusive and innovative design for the drain pan. This design insures proper drainage, preventing conditions of water stagnation that could result in microbial growth. All the air handlers feature a factory installed belt drive and ball bearing evaporator fan with adjustable shelves. The unit can be installed indoors; the condenser air can be ducted to the outside or installed in a remote location. For free horizontal application, the optional discharge plenum with aluminum grills insures a quiet operation and maintains the aesthetics of the units. In the return section an optional aluminum grill grants an easy and elegant installation. 3 Filter Types To meet Commercial and Industrial needs you can select the filter media for the application. Nylon Electrostatic Filters Wire Mesh Permanent Filters Throwaway Filters Many other options available as special (Contact your local Trane Representative). Scroll Compressor offers significant efficiency and reliable benefits. With fewer moving parts than comparable reciprocating compressors, there is less internal friction and therefore greater efficiency. A smooth compressor cycle, due to the low torque variation, creates less stress on the motor for greater reliability and efficiency. How the Scroll Compressor Works General The compressor has two scrolls. The top scroll is fixed and the bottom scroll orbits. Each scroll has walls in a spiral shape that intermesh. Inlet — First Orbit As the bottom scroll orbits, two refrigerant gas pockets are formed and enclosed. Compression — Second orbit The refrigerant gas is compressed as the volume is reduced closer to the center of the scroll. Discharge — Third Orbit The gas is compressed further and discharged through a small port in the center of the fixed scroll. PKG-PRC007-EN 5 Features and Benefits Integrated Self-Contained Systems: Profitable, Simple Genius is three times ingenious in many ways. Integrated Comfort™ System (ICS) Trane’s Integrated Comfort™ system improves job profit and increases job control by combining Trane selfcontained units and a Tracker® building management system. This integrated system provides total building comfort and control. The primary motivation for building owners/managers in making the purchasing decision of an HVAC controls system is no longer just saving energy; it is having the ability to automate their facilities and the convenience of interface to control systems. Available in 3 models SRVE - Self-contained unit with INTEGRATED air cooled condenser 3 Control Options Standard Thermostat All units are furnished with a standard thermostat that can be installed remotely or directly on the equipment. SIVE - Self contained unit with REMOTE air-cooled condenser SAVE - Self-contained WATER-cooled unit with shell and tube condenser Available 3 Colors The attractive highly functional design of the Genius line offers the customers the selection of three equipment colors to blend with any architectural style: Gray Black Red 3 Motor Sizes The units have the capability to meet any static pressure application up to 1.5” with their 3 options: - Low Static Motor Option - Medium Static Option - High Static Option Programmable Thermostat (PT) PT programming is very simple! PT has a display that shows the hour, the day of the week, the selected program and the ambient temperature. PT can be programmed for up to four setpoints for each day of the week. Using the button “timed-override” the customer can prolong the machine operation beyond the programmed schedule, according to customer needs. As an additional benefit the Micro allows the Genius to be integrated to the Tracker. This ability allows the multiple units to be controlled and diagnosed from a central location, from across town or even across the country. Just imagine the HVAC installed in your facility capable of being scheduled, monitored and let you know when it is having problems. Microcontrol This state of the art control offers a complete family of sensors and wall mounted devices to compliment the capabilities of the Trane Micro. 3 Filter Options Three filter options exist which may be installed in Genius units. 1. Permanent washable filters of electrostatic fabric (standard). 2. Disposable 2” filters. 3. The combination of the two placed in series. 6 PKG-PRC007-EN Features Summary Quality and Reliability • Galvanized steel casing • Synthetic enamel paint • Innovative Drain Pan • Scroll Compressors Flexibility • Air or Water Cooled • Free discharge plenum or ducted discharge • Voltages available: 220/3/60, 440/3/60, 380/3/60 and 380/50/3 Controls • Thermostat unit mounted or remote • Optional Programmable thermostat • Optional Microprocessor • ICS compatible, Tracker is your ideal partner for small buildings applications. Wide range of Models available: SRVE: Self Contained with Integral Air Cooled Condenser SIVE: Self Contained with Remote Air Condenser SAVE: Self Contained with Water cooled Nominal Capacity: From 5 to 15 Tons You can reach up to 1.5” esp with our Double Inlet Forward curved Supply fan. It also has variable V-belt drives. The case has been insulated with BIDIM insulation. Other options: Aluminum decorative grill Plenum discharge box for free air discharge Service Valves Sight Glass Solenoid Valve Filters • Throwaway • Washable - Nylon type • Washable - Aluminum Mesh PKG-PRC007-EN 7 Model Number Description 8 PKG-PRC007-EN General Data Table GD-1 — Genius – General Data SAVE Model Nominal TR Capacity Length (mm) Depth (mm) Height (mm) Height w/ Plenum Box (mm) Net Weight (kg) SRVE Model Nominal TR Capacity Length (mm) Depth (mm) Height (mm) Height w/ Plenum Box (mm) Net Weight (kg) SIVE Model Nominal TR Capacity Evaporator Units Quantity/Model Length (mm) Depth (mm) Height (mm) Height w/ Plenum Box (mm) Net Weight (kg) Condensing Units Quantity/Model Length (mm) Depth (mm) Height (mm) Net Weight (kg) Compressor Quantity TR Evaporator Coil Rows Finned Height (mm) Finned Length (mm) Finned Clearance (m) FPF ( Fins Per Foot) Evaporator Fan Quantity Diameter x Length Plenum Box Option (CV) Standard Motor Option (CV) Motor Option 1 (CV) Motor Option 2 (CV) Minimum Air Flow (m3/h) Maximum Air Flow (m3/h) Condenser Fan (SRVE and CRCB) Quantity Diameter x Length Motor (CV) Air Flow (CFM) Water Condenser (SAVE) Minimum Water Flow GPM Maximum Water Flow GPM Maximum Pressure Drop (ca feet) Condenser Coil (SRVE, CRCB) Rows Finned Height (mm) Finned Length (mm) FPF (Fins per Foot) PKG-PRC007-EN 050 T 5 960 600 2000 2295 247 050 T 5 960 720 2000 2295 268 050 T 5 075 T 7.5 1190 600 2000 2295 288 075 T 7.5 1190 720 2000 2295 310 075 T 7.5 100 2T 10 1500 600 2000 2295 376 100 2T 10 1500 830 2000 2295 416 100 2T 10 125 2T 12.5 1700 600 2000 2295 440 125 2T 12.5 1700 1000 2000 2295 459 125 2T 12.5 150 2T 15 1700 600 2000 2295 461 150 2T 15 1700 1000 2000 2295 490 150 2T 15 1/SIVE050 960 600 2000 2295 190 1/SIVE075 1190 600 2000 2295 225 1/SIVE100 1500 600 2000 2295 235 1/SIVE125 1700 600 2000 2295 347 1/SIVE 150 1700 600 2000 2295 392 1/CRCB050 987 631 890 93 1/CRCB075 1241 631 890 124 1/CRCB100 1341 631 941 139 1/CRCB125 1646 714 1018 180 1/CRCB150 1646 714 1247 212 1/5 1 / 7.5 2/5 5 + 7.5 2 / 7.5 3 536 711 0.38 132 3 508 965 0.49 132 3 612 1143 0.70 132 3 663 1328 0.88 132 4 714 1321 0.94 132 1 270 x 270 0.5 1.0 1.0 1.5 3060 3825 1 321 x 321 0.5 1.5 2.0 3.0 4590 5740 2 270 x 270 0.5 1.5 2.0 3.0 6120 7650 2 321 x 321 0.5 2.0 3.0 4.0 7650 9560 2 321 x 321 1.0 3.0 4.0 5.0 9180 11475 1 321 x 321 1.0 5450 1 321 x 321 3.0 8315 2 270 x 270 3.0 9935 2 321 x 321 4.0 13930 2 321 x 321 5.0 17320 1.4 4.0 1.9 2.0 6.0 4.6 2.7 8.0 1.8 3.4 9.9 3.0 4.1 11.9 3.1 4 711 762 168 4 813 1016 168 4 864 1143 168 4 940 1473 168 4 1168 1473 168 9 Selection Procedure The selection of a Genius self-contained unit can be accomplished in three easy steps. 1 LOAD: Determine the load requirements for heating and cooling (include outside air) using Trane’s load estimate forms, TRACE® Easy/600 or any standard method. 2 UNIT TYPE: Self-contained air conditioners are available in either water-cooled or remote air-cooled models to match individual needs. 3 SELECT THE UNIT: The conditions under which the unit must operate and the design load will give the final selection. SELECTION EXAMPLE Design Conditions Water-cooled unit Entering air temperature — 80/67 F Total gross capacity required — 55,000 BTUH Entering water temperature — 85 F Leaving water temperature — 92 F Airflow — 1,950 CFM at 0.5” duct static pressure. Voltage Unit Selection Tentatively select a 5-ton unit — Model SAVE050. Refer to Table PD-6 to obtain gross total and sensible unit capabilities, gpm, and leaving water temperature at nominal conditions: Total MBh — 60.6 Sensible MBh — 43.5 GPM — 14.5 LWT — 95 The SAVE-050 meets the total and sensible design requirements. Since the difference between entering and leaving water is 7°F multiply the capacities and water flow by correction factors on Capacity Correction Factor Table. Solution 1. Select Unit Initially Select a 10-Ton Unit Cooling capacity multiplier Sensible capacity multiplier Water flow multiplier 80/67 EAT 95 F AMB = 118.7 MBh Total Gross 4200 CFM 86.6 MBh Sensible 1.01 1.05 1.39 60.6 x 1.01 = 61.21 MBh 43.5 x 1.01 = 43.94 MBh 14.5 x 1.39 = 20.16 GPM Refer to Table PD-1 to determine approximate brake horsepower and fan rpm: 1035 rpm and 0.66 bhp. Determine net capacities by subtracting fan motor heat from gross capacities: 2.8 x 0.66 bph = 1.85 MBh Net total capacity = 61.21 - 1.85 = 59.36 MBh Net sensible capacity = 43.94 - 1.85 = 42.09 MBh Supply air temperature DB Qs = 1.085 x CFM x (Tr-TS) 42,090 = 1.085 x 1950 x (80-TS) 42,090 TS = 80 (1.085) (1950) TS = 60.1°F Air-Cooled Design Conditions — 80 F/67 F DB/WB return air temperature — 95 F Ambient — 109300 BTUH Total Net — 76500 BTUH Sensible Net — 0.380 External Static Pressure (evaporator fan) — 4200 CFM — 0.25 External static pressure (condenser fan) From Table PD-13 2. Fan speed and BHP determination Total Static Pressure Evaporator 0.380 esp From Table PD-3 Evaporator 10-ton unit 4200 CFM = 1107 RPM 0.5 ESP = 1.63 BHP Note: If values fall between cfm’s or esp’s it is proper to interpolate between values. Do not extrapolate beyond values in catalog. Contact Trane marketing department for assistance. Fan Motor Heat Equation Fan motor heat = 2.8 x 1.63 = 4.56 MBh Net total capacity = 118.7 - 4.50 = 114.14 MBh Net sensible capacity = 86.6 - 4.56 = 82.04 MBh Conclusion: Required — 109300 BTUH Total Net 76500 BTUH Total Sensible Net Provided — 114140 BTUH Total Net 82040 BTUH Total Net The 10-ton unit is the proper choice for this application. Required 1. Select unit 2. Fan speed and BHP for a) Evaporator fan b) Condenser fan 3. Supply air temperature DB 10 PKG-PRC007-EN Performance Data Fan Data Three transmission options exist for the evaporator fan motor: Std. option, option 1, option 2. In addition, there is an option for those cases in which the unit is operated with a plenum box. The motors for each transmission option can be found in the general facts tables. Table PD-1 — Fan Performance SRVE/SIVE/SAVE 5 Tons Option STD Option OP1 Option OP2 MT MS FS B Model 5 TR MT 1.0 CV MS: 78,5 A 106,5 FS: 184 (8") B: 1X A36 Model 5 TR MT 1.0 CV MS: 78,5 A 106,5 FS: 133 (6") B: 1X A32 Model 5 TR MT 1.5 CV MS: 78.5 A 106.5 BS: 108 (5") B: 1X A31 CFM 1802 1877 1952 2028 2102 2178 2253 Airflow CFM (m3/h) 1802 3060 1877 3188 1952 3315 2028 3443 2102 3570 2178 3698 2253 3825 CFM 1802 1877 1952 2028 2102 2178 2253 Airflow (m3/h) 3060 3188 3315 3443 3570 3698 3825 .08 (19.9) RPM 815 843 869 897 925 952 981 BHP 0.40 0.45 0.50 0.56 0.62 0.68 0.75 External static pressure with permanent air filter inches of water (Pa) .16 .24 .31 .39 (39.8) (59.8) (77.2) (97.1) RPM BHP RPM BHP RPM BHP RPM 852 0.43 888 0.45 923 0.48 957 879 0.48 914 0.51 948 0.53 981 904 0.53 938 0.56 971 0.59 1003 931 0.59 964 0.62 996 0.65 957 0.65 989 0.68 984 0.71 External static pressure with permanent air filter inches of water (Pa) .31 .39 .50 .63 .79 (77.2) (97.1) (124.5) (156.9) (196.7) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1055 0.61 1117 0.68 1013 0.60 1076 0.67 1136 0.74 1035 0.66 1096 0.73 1155 0.80 1027 0.68 1058 0.72 1117 0.79 1175 0.86 1020 0.71 1051 0.75 1081 0.78 1139 0.85 1195 0.93 1045 0.78 1075 0.81 1104 0.85 1160 0.92 1215 1.00 1071 0.85 1100 0.88 1128 0.92 1183 0.99 1237 1.07 .16 (39.8) RPM BHP .24 (59.8) RPM BHP 1012 0.78 1015 0.74 1042 0.81 Airflow (m3/h) 3060 3188 3315 3443 3570 3698 3825 External static pressure with permanent air filter inches of water (Pa) .94 1.10 1.26 1.42 (234.1) (273.9) (313.7) (353.6) RPM BHP RPM BHP RPM BHP RPM 1289 0.91 1343 1305 0.97 1358 1267 0.95 1320 1.03 1372 1284 1.02 1337 1.10 1387 1302 1.09 1353 1.16 1403 1269 1.08 1320 1.15 1371 1.23 1420 1289 1.14 1340 1.22 1389 1.30 1437 .50 (124.5) RPM BHP 990 0.54 BHP 0.51 0.57 0.62 .94 (234.1) RPM BHP 1176 0.75 1195 0.81 1212 0.88 1230 0.94 1249 1.01 BHP 0.98 1.05 1.11 1.18 1.24 1.31 1.39 1.10 (273.9) RPM BHP 1234 0.83 1251 0.89 1.57 (390.9) RPM 1395 1409 1422 1437 1452 1467 BHP 1.05 1.12 1.19 1.25 1.32 1.39 = Motor (CV). = Motor Sheave, variable pitch (mm). = Fan Sheave (mm). = Belt. PKG-PRC007-EN 11 Performance Data Fan Data Table PD-2 — Fan Performance SRVE/SIVE/SAVE 7.5 Tons Option STD Option OP1 Option OP2 MT MS FS B 12 Model 7.5 TR MT 1.5 CV MS: 78,5 A 106,5 BS: 209 (9") B: 1X A35 Model 7.5 TR MT 2.0 CV MS: 78,5 A 106,5 BS: 159 (7") B: 1X A32 Model 7.5 TR MT 3.0 CV MS: 80 A 110 BS: 118 (5") B: 1X B27 CFM 2703 2815 2927 3041 3154 3267 3380 Airflow (m3/h) 4590 4780 4970 5163 5355 5548 5740 .08 (19.9) RPM 688 712 735 760 784 808 834 .24 Airflow (59.8) CFM (m3/h) RPM BHP 2703 4590 2815 4780 2927 4970 3041 5163 3154 5355 3267 5548 3380 5740 885 1.34 CFM 2703 2815 2927 3041 3154 3267 3380 BHP 0.64 0.72 0.81 0.90 1.01 1.12 1.24 External static pressure with permanent air filter inches of water (Pa) .16 .24 .31 .39 (39.8) (59.8) (77.2) (97.1) RPM BHP RPM BHP RPM BHP RPM 720 0.68 751 0.72 781 0.77 811 743 0.76 773 0.81 802 0.86 831 765 0.85 794 0.90 822 0.95 850 788 0.95 816 1.00 844 1.05 871 811 1.06 838 1.10 865 1.15 834 1.17 861 1.22 859 1.29 External static pressure with permanent air filter inches of water (Pa) .31 .39 .50 .63 .79 .94 1.10 (77.2) (97.1) (124.5) (156.9) (196.7) (234.1) (273.9) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 896 0.97 950 1.08 1002 1.19 1052 1.30 913 1.06 966 1.17 1017 1.28 1066 1.39 931 1.16 982 1.26 1031 1.37 1079 1.49 897 1.15 949 1.25 999 1.36 1047 1.47 1094 1.59 891 1.21 917 1.26 968 1.36 1016 1.47 1064 1.59 1110 1.71 886 1.27 912 1.32 937 1.37 986 1.47 1034 1.58 1080 1.70 1125 1.83 910 1.39 935 1.44 959 1.49 1007 1.59 1053 1.70 1098 1.83 1142 1.96 Airflow (m3/h) 4590 4780 4970 5163 5355 5548 5740 External static pressure with permanent air filter inches of water (Pa) 1.26 1.42 (313.7) (353.6) RPM BHP RPM BHP 1169 1185 1.97 2.15 1159 1171 1184 1198 1211 1227 1.61 1.74 1.86 2.01 2.16 2.32 .50 (124.5) RPM BHP 840 0.87 859 0.96 877 1.05 BHP 0.82 0.91 0.99 1.10 1.26 (313.7) RPM BHP 1100 1.41 1113 1.50 1126 1.60 1140 1.72 1154 1.83 1.42 (353.6) RPM BHP 1147 1.51 1.57 (390.9) RPM 1193 1204 1215 1227 1240 1253 1268 BHP 1.60 1.75 1.88 2.03 2.17 2.34 2.50 = Motor (CV). = Motor Sheave, variable pitch (mm). = Fan Sheave (mm). = Belt. PKG-PRC007-EN Performance Data Fan Data Table PD-3 — Fan Performance SRVE/SIVE/SAVE 10 Tons Option STD Model 10 TR MT 1.5 CV MS: 78,5 A 106,5 BS: 184 (8") B: 1X A35 CFM 3604 3754 3905 4055 4205 4355 4505 .08 (19.9) Airflow (m3/h) 6120 6375 6630 6885 7140 7395 7650 RPM 839 866 895 924 954 984 .08 .16 Model Airflow (19.9) (39.8) Option 10 TR CFM (m3/h) RPM BHP RPM BHP 3604 6120 MT 2.0 CV 3754 6375 MS: 78,5 A 106,5 3905 6630 OP1 BS: 133 (6") 4055 6885 B: 1X A31 4205 7140 4355 7395 1015 1.49 4505 7650 1013 1.56 1043 1.63 Option OP2 MT MS FS B Model 10 TR MT 3.0 CV MS: 80 A 110 BS: 118 (5") B: 1X B31 Airflow CFM (m3/h) 3604 6120 3754 6375 3905 6630 4055 6885 4205 7140 4355 7395 4505 7650 .63 (156.9) RPM BHP 1188 1212 1.92 2.06 External static pressure with permanent air filter inches of water (Pa) .16 .24 .31 (39.8) (59.8) (77.2) BHP RPM BHP RPM BHP RPM 0.84 875 0.89 911 0.94 945 0.94 902 0.99 936 1.05 969 1.04 929 1.10 963 1.16 995 1.16 957 1.22 989 1.28 1.29 986 1.35 1.42 External static pressure with permanent air filter inches of water (Pa) .31 .39 .50 .63 .79 (77.2) (97.1) (124.5) (156.9) (196.7) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 1012 1.13 1075 1.26 1136 1.41 1034 1.24 7096 1.38 1156 1.53 1027 1.29 1058 1.36 1118 1.51 1176 1.66 1021 1.35 1051 1.42 1082 1.49 1140 1.64 1197 1.79 1017 1.42 1048 1.49 1078 1.56 1107 1.63 1164 1.78 1045 1.55 1075 1.63 1104 1.70 1132 1.77 1072 1.70 1101 1.77 1130 1.84 1157 1.92 .24 (59.8) RPM BHP 1220 1242 1265 1.93 2.07 2.22 1252 1273 1295 1316 1.94 2.08 2.23 2.37 1.97 2.10 2.24 2.39 2.53 1322 1340 1357 1376 1395 1414 BHP 1.00 1.11 1.23 RPM 979 1002 BHP 1.07 1.17 .94 1.10 1.26 (234.1) (273.9) (313.7) RPM BHP RPM BHP RPM BHP 1195 1.55 1252 1.71 1307 1.87 1213 1.68 1269 1.83 1232 1.81 External static pressure with permanent air filter inches of water (Pa) .79 .94 1.10 1.26 (96.7) (234.1) (273.9) (313.7) RPM BHP RPM BHP RPM BHP RPM BHP 1287 1305 1325 1346 1366 .39 (97.1) 1.98 2.12 2.26 2.40 2.54 2.69 1.42 (353.6) RPM BHP 1360 2.01 1375 2.14 1391 2.28 1407 2.42 1425 2.56 1444 2.71 1.57 (390.9) RPM BHP 1412 2.16 1425 2.29 1441 2.43 1456 2.57 1473 2.71 = Motor (CV). = Motor Sheave, variable pitch (mm). = Fan Sheave (mm). = Belt. PKG-PRC007-EN 13 Performance Data Fan Data Table PD-4 — Fan Performance SRVE/SIVE/SAVE 12.5 Tons Option STD Option OP1 Option OP2 MT MS FS B 14 Model 12.5 TR MT 2.0 CV MS: 78,5 A 106,5 BS: 184 (8") B: 1X A33 Model 12.5 TR MT 3.0 CV MS: 79 A 105 FS: 169 (7") B: 1X B32 Model 12.5 TR MT 4.0 CV MS: 79 A 105 FS: 143 (6") B: 1X B29 Airflow CFM (m3/h) 4505 7650 4694 7970 4882 8290 5069 8608 5256 8925 5445 9243 5630 9560 CFM 4505 4694 4882 5069 5256 5445 5630 CFM 4505 4694 4882 5069 5256 5445 5630 .08 (19.9) RPM BHP 630 0.81 649 0.93 670 1.04 690 1.15 711 1.28 731 1.41 753 1.56 Airflow (m3/h) 7650 7970 8290 8608 8925 9243 9560 Airflow (m3/h) 7650 7970 8290 8608 8925 9243 9560 External static pressure with permanent air filter inches of water (Pa) .16 .24 .31 .39 (39.8) (59.8) (77.2) (97.1) RPM BHP RPM BHP RPM BHP RPM BHP 666 0.89 701 0.98 735 1.08 768 1.18 684 1.01 718 1.09 751 1.18 783 1.27 703 1.12 736 1.20 768 1.29 799 1.39 723 1.24 754 1.32 785 1.41 816 1.51 743 1.37 774 1.46 804 1.55 833 1.65 762 1.50 792 1.60 821 1.69 850 1.79 783 1.65 812 1.75 841 1.85 .39 (97.1) RPM BHP 868 1.95 External static pressure with permanent air filter inches of water (Pa) .50 .63 .79 (124.5) (156.9) (195.7) RPM BHP RPM BHP RPM BHP 919 1.62 874 1.57 931 1.79 888 1.69 944 1.91 902 1.82 957 2.04 918 1.97 971 2.18 878 1.90 932 2.11 985 2.33 896 2.06 949 2.27 1000 2.49 .50 (124.5) RPM BHP 800 1.29 814 1.37 830 1.49 845 1.61 862 1.75 .94 (234.1) RPM 975 985 997 1010 1023 1035 External static pressure with permanent air filter inches of water (Pa) .94 1.10 1.26 1.42 (234.1) (273.9) (313.7) (353.6) RPM BHP RPM BHP RPM BHP RPM 1081 2.26 1131 1089 2.44 1139 1099 2.56 1148 1109 2.69 1156 1073 2.62 1121 2.84 1167 1084 2.77 1131 2.98 1177 1050 2.71 1098 2.93 1144 3.15 1189 BHP 2.52 2.65 2.77 2.89 2.95 3.10 3.30 BHP 1.88 2.00 2.13 2.26 2.40 2.55 .63 (156.9) RPM BHP 8.61 1.50 1.10 (273.9) RPM BHP 1029 2.06 1038 2.23 1049 2.35 1060 2.48 1.57 (390.9) RPM 1179 1187 1195 1203 1213 BHP 2.73 2.81 2.92 3.13 3.20 = Motor (CV). = Motor Sheave, variable pitch (mm). = Fan Sheave (mm). = Belt. PKG-PRC007-EN Performance Data Fan Data Table PD-5 — Fan Performance SRVE/SIVE/SAVE 15 Tons Option STD Option OP1 Option OP2 MT MS FS B Model 15 TR MT 3.0 CV MS: 79 A 105 FS: 219 (9") B: 1X B35 Model 7.5 TR MT 4.0 CV MS: 79 A 105 FS: 169 (7") B: 1X B31 Model 15 TR MT 5.0 CV MS: 79 A 105 FS: 143 (6") B: 1X B29 CFM 5406 5632 5857 6080 6302 6530 6758 Airflow (m3/h) 9180 9563 9945 10323 10700 11088 11475 .08 (19.9) RPM 664 686 707 728 749 771 793 .16 Airflow (39.8) CFM (m3/h) RPM BHP 5406 9180 5632 9563 5857 9945 6080 10323 6302 10700 6530 11088 6758 11475 819 2.41 CFM 5406 5632 5857 6080 6302 6530 6758 Airflow (m3/h) 9180 9563 9945 10323 10700 11088 11475 BHP 1.22 1.36 1.52 1.69 1.88 2.08 2.30 External static pressure with permanent air filter inches of water (Pa) .16 .24 .31 .39 (39.8) (59.8) (77.2) (97.1) RPM BHP RPM BHP RPM BHP RPM BHP 696 1.30 728 1.38 759 1.48 789 1.57 717 1.45 747 1.54 777 1.64 806 1.73 737 1.61 766 1.71 795 1.81 757 1.79 785 1.89 813 1.99 777 1.98 804 2.08 798 2.19 External static pressure with permanent air filter inches of water (Pa) .24 .31 .39 .50 .63 .79 .94 (59.8) (77.2) (97.1) (124.5) (156.9) (196.7) (234.1) RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP RPM BHP 875 1.87 930 2.08 983 2.30 835 1.83 890 2.03 944 2.25 995 2.47 824 1.91 852 2.01 906 2.21 958 2.43 1008 2.65 841 2.09 868 2.19 921 2.40 972 2.61 1021 2.83 832 2.19 858 2.28 885 2.39 936 2.59 986 2.80 1034 3.02 825 2.29 851 2.40 877 2.50 903 2.60 953 2.81 1002 3.02 1049 3.24 845 2.52 871 2.62 896 2.72 921 2.85 970 3.03 1017 3.23 1064 3.46 RPM 1081 1095 1108 External static pressure with permanent air filter inches of water (Pa) 1.10 1.26 1.42 (273.9) (313.7) (353.6) BHP RPM BHP RPM 1130 1093 2.91 1140 1104 3.10 1150 1115 3.29 1160 3.26 1126 3.50 1171 3.48 1139 3.74 1183 3.71 1152 4.00 1195 1.10 (273.9) RPM BHP 1033 2.52 1045 2.69 1057 2.87 1069 3.06 .50 (124.5) RPM BHP 818 1.66 1.26 (313.7) RPM BHP 1082 2.74 1.57 (390.9) BHP 2.95 3.13 3.33 3.53 3.77 4.00 4.20 RPM 1176 1185 1194 1204 1214 1225 1236 BHP 3.17 3.37 3.58 3.80 4.02 4.27 4.45 = Motor (CV). = Motor Sheave, variable pitch (mm). = Fan Sheave (mm). = Belt. PKG-PRC007-EN 15 Performance Data Water Cooled 60 Hz Table PD-6 — Gross Cooling Capacities SAVE-050 English ENT Water Temp (°F) 75 CFM 1800 1950 2100 2250 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 55.0 55.2 56.7 59.2 55.7 56.0 58.0 60.7 56.3 56.9 59.1 61.9 56.9 57.7 60.3 63.1 SHC 45.2 53.1 57.8 60.4 46.6 54.9 59.1 61.8 48.1 56.6 60.3 63.1 49.5 58.1 61.4 64.4 85 Entering Wet Bulb Temperature (°F) 73 61 67 GPM 12.8 12.8 13.2 14.1 13.2 13.2 13.7 14.1 13.2 13.7 14.1 14.5 13.7 13.7 14.1 14.5 TGC 61.6 61.5 61.5 61.5 62.3 62.3 62.2 63.4 62.9 62.9 62.8 63.1 63.5 63.5 63.4 64.0 SHC 35.2 43.4 50.1 56.7 36.0 44.7 51.9 58.8 36.9 46.0 53.6 60.8 37.6 47.3 55.2 62.6 GPM 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 15.0 15.0 15.0 15.0 TGC 68.6 68.6 68.5 68.5 69.4 69.3 69.3 69.2 70.1 70.0 70.0 69.9 70.8 70.7 70.7 70.6 SHC 24.9 33.1 39.8 46.5 25.2 33.8 41.0 48.1 25.4 34.5 42.1 49.7 25.6 35.3 43.2 51.1 GPM 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 16.3 16.3 16.3 16.3 16.3 16.3 16.3 16.3 TGC 53.5 53.7 55.4 58.0 54.1 54.6 56.7 59.4 54.7 55.4 57.9 60.7 55.2 56.2 58.9 61.8 SHC 44.4 52.3 56.5 59.1 45.9 54.1 57.8 60.6 47.4 55.7 59.0 61.8 48.7 57.0 60.1 63.0 GPM 12.8 12.8 13.2 14.1 13.2 13.2 13.7 14.1 13.2 13.2 14.1 14.5 13.2 13.7 14.1 14.5 67 TGC 59.9 59.9 59.8 59.9 60.7 60.6 60.6 60.8 61.3 61.3 61.2 61.6 61.9 61.8 61.8 62.3 SHC 34.4 42.6 49.4 56.0 35.3 43.5 51.1 58.1 36.1 45.3 52.8 60.0 37.0 46.5 54.5 61.7 73 GPM 14.5 14.5 14.1 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 15.0 TGC 67.0 66.8 66.8 66.7 67.7 67.7 67.6 67.6 68.4 68.3 68.3 68.2 69.0 68.9 68.9 68.8 SHC 24.4 32.4 39.2 45.9 24.6 33.2 40.3 47.5 24.8 33.9 41.5 49.0 25.0 34.5 42.5 50.5 GPM 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 16.3 15.9 15.9 15.9 16.3 16.3 16.3 16.3 Table PD-6 — Gross Cooling Capacities SAVE-050 (Cont.) CFM 1800 1950 2100 2250 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 51.9 52.2 54.2 56.8 52.5 53.0 55.4 58.1 53.1 54.0 56.5 59.3 53.7 54.8 57.6 60.4 SHC 43.7 51.5 55.2 57.9 45.2 53.1 56.5 59.2 46.6 54.6 57.6 60.5 48.0 55.9 58.7 61.5 ENT Water Temp (°F) 95 Entering Wet Bulb Temperature (°F) 67 GPM 12.8 12.8 13.7 14.1 13.2 13.2 13.7 14.1 13.2 13.7 14.1 14.5 13.2 13.7 14.1 15.0 TGC 58.3 58.2 58.2 58.3 59.0 58.9 58.9 59.1 59.6 59.5 59.5 59.9 60.2 60.1 60.1 60.8 SHC 33.7 41.9 48.6 55.2 34.5 43.3 50.4 57.2 35.4 44.5 52.2 59.1 36.2 45.8 53.8 60.8 GPM 14.1 14.1 14.1 14.1 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 14.5 15.0 TGC 65.2 65.1 65.1 65.0 65.9 65.8 65.8 65.7 66.5 66.5 66.4 66.4 67.2 67.1 67.1 67.0 73 SHC 23.6 31.8 38.5 45.3 23.8 32.6 39.7 46.8 24.2 33.3 40.8 48.3 24.4 33.9 41.9 49.8 GPM 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 15.9 16.3 16.3 16.3 16.3 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) Capacity Correction Factor Table Delta T Water (°F) 4.5 7.2 10.0 12.6 15.3 18.0 16 GPM 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. MBh 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. MBh 1.01 1.01 1.00 1.00 1.00 0.99 PKG-PRC007-EN Water Cooled 60 Hz Performance Data Table PD-6 — Gross Cooling Capacities SAVE-050 Metric ENT Water Temp (°C) 24.0 m3/h 3060 3315 3570 3825 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 16.1 16.2 16.6 17.4 16.3 16.4 17.0 17.8 16.5 16.7 17.3 18.1 16.7 16.9 17.7 18.5 SHC 13.2 15.6 16.9 17.7 13.7 16.1 17.3 18.1 14.1 16.6 17.7 18.5 14.5 17.0 18.0 18.9 29.5 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 l/s 0.81 0.81 0.83 0.89 0.83 0.83 0.86 0.89 0.83 0.86 0.89 0.92 0.86 0.86 0.89 0.92 TGC 18.0 18.0 18.0 18.0 18.3 18.3 18.2 18.6 18.4 18.4 18.4 18.5 18.6 18.6 18.6 18.7 SHC 10.3 12.7 14.7 16.6 10.6 13.1 15.2 17.2 10.8 13.5 15.7 17.8 11.0 13.8 16.2 18.3 l/s 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.94 0.94 0.94 0.94 TGC 20.1 20.1 20.1 20.1 20.3 20.3 20.3 20.3 20.6 20.5 20.5 20.5 20.7 20.7 20.7 20.7 SHC 7.3 9.7 11.7 13.6 7.4 9.9 12.0 14.1 7.4 10.1 12.3 14.6 7.5 10.3 12.6 15.0 l/s 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.03 1.03 1.03 1.03 1.03 1.03 1.03 1.03 TGC 15.7 15.7 16.2 17.0 15.8 16.0 16.6 17.4 16.0 16.2 17.0 17.8 16.2 16.5 17.3 18.1 SHC 13.0 15.3 16.6 17.3 13.4 15.8 16.9 17.8 13.9 16.3 17.3 18.1 14.3 16.7 17.6 18.5 l/s 0.81 0.81 0.83 0.89 0.83 0.83 0.86 0.89 0.83 0.83 0.89 0.92 0.83 0.86 0.89 0.92 19.5 TGC 17.6 17.6 17.5 17.6 17.8 17.7 17.7 17.8 18.0 18.0 17.9 18.0 18.1 18.1 18.1 18.3 SHC 10.1 12.5 14.5 16.4 10.3 12.8 15.0 17.0 10.6 13.3 15.5 17.6 10.8 13.6 16.0 18.1 23.0 l/s 0.92 0.92 0.89 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.94 TGC 19.6 19.6 19.6 19.6 19.8 19.8 19.8 19.8 20.0 20.0 20.0 20.0 20.2 20.2 20.2 20.2 SHC 7.1 9.5 11.5 13.4 7.2 9.7 11.8 13.9 7.3 9.9 12.2 14.4 7.3 10.1 12.5 14.8 l/s 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.03 1.00 1.00 1.00 1.03 1.03 1.03 1.03 Table PD-6 — Gross Cooling Capacities SAVE-050 (Cont.) m3/h 3060 3315 3570 3825 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 15.2 15.3 15.9 16.6 15.4 15.5 16.2 17.0 15.6 15.8 16.6 17.4 15.7 16.1 16.9 17.7 SHC 12.8 15.1 16.2 17.0 13.2 15.6 16.6 17.4 13.7 16.0 16.9 17.7 14.1 16.4 17.2 18.0 ENT Water Temp (°C) 35.0 Entering Wet Bulb Temperature (°C) 19.5 l/s 0.81 0.81 0.86 0.89 0.83 0.83 0.86 0.89 0.83 0.86 0.89 0.92 0.83 0.86 0.89 0.94 TGC 17.1 17.1 17.1 17.1 17.3 17.3 17.3 17.3 17.5 17.4 17.4 17.6 17.6 17.6 17.6 17.8 SHC 9.9 12.3 14.2 16.2 10.1 12.7 14.8 16.8 10.4 13.0 15.3 17.3 10.6 13.4 15.8 17.8 l/s 0.89 0.89 0.89 0.89 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.92 0.94 TGC 19.1 19.1 19.1 19.0 19.3 19.3 19.3 19.3 19.5 19.5 19.5 19.5 19.7 19.6 19.6 19.6 23.0 SHC 6.9 9.3 11.3 13.3 7.0 9.5 11.6 13.7 7.1 9.8 12.0 14.2 7.1 9.9 12.3 14.6 l/s 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.00 1.03 1.03 1.03 1.03 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) Capacity Correction Factor Table Delta T Water (°C) 2.5 4.0 5.5 7.0 8.5 10.0 PKG-PRC007-EN l/s 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. kW 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. kW 1.01 1.01 1.00 1.00 1.00 0.99 17 Performance Data Water Cooled 60 Hz Table PD-7 — Gross Cooling Capacities SAVE-075 English ENT Water Temp (°F) 75 CFM 2700 2925 3150 3375 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 79.4 79.8 82.5 86.5 80.5 81.1 84.4 88.5 81.3 124.4 86.1 90.3 82.2 83.5 87.7 92.1 SHC 64.2 75.6 81.7 85.7 66.3 78.1 83.6 87.7 68.4 80.3 85.3 89.5 70.2 82.3 86.8 91.2 85 Entering Wet Bulb Temperature (°F) 73 61 67 GPM 18.1 18.1 18.5 19.4 18.1 18.5 18.9 19.8 18.5 18.5 19.4 20.3 18.5 18.9 19.8 20.3 TGC 89.4 89.3 89.1 89.4 90.4 90.3 90.3 90.6 91.5 91.4 91.3 91.8 92.3 92.2 92.1 93.0 SHC 49.9 61.6 71.5 81.1 51.1 63.6 74.0 84.0 52.3 65.5 76.4 86.7 53.4 67.3 78.9 89.3 GPM 19.8 19.8 19.8 19.8 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.7 20.3 20.7 20.7 TGC 100.1 100.0 99.9 99.7 101.2 101.1 101.0 100.9 102.3 102.2 102.1 102.0 103.1 103.0 103.0 102.9 SHC 35.3 47.0 56.8 66.6 35.7 48.2 58.5 68.8 36.0 49.1 60.1 71.0 36.3 50.2 61.6 73.1 GPM 22.0 22.0 22.0 22.0 22.5 22.5 22.0 22.0 22.5 22.5 22.5 22.5 22.5 22.5 22.5 22.5 TGC 77.2 77.7 80.6 84.5 78.1 79.0 82.5 86.5 79.0 80.2 84.1 88.3 79.7 81.4 85.6 89.9 SHC 63.1 74.3 79.8 83.7 65.2 76.8 81.7 85.7 67.2 78.9 83.3 87.5 69.2 80.6 84.8 89.0 GPM 18.1 18.1 18.5 19.4 18.1 18.5 18.9 19.8 18.5 18.5 19.4 20.3 18.5 18.9 19.8 20.3 67 TGC 86.8 86.7 86.6 86.8 87.9 87.6 87.6 88.1 88.7 88.6 88.6 89.3 89.6 89.5 89.4 90.4 SHC 48.8 60.6 70.4 79.9 50.0 63.0 72.9 82.7 51.2 64.4 75.4 85.4 52.3 66.2 77.7 87.8 73 GPM 19.8 19.8 19.8 19.8 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.7 TGC 97.1 97.0 97.0 96.9 98.3 98.2 98.1 97.9 99.2 99.1 99.0 98.9 100.1 100.0 99.9 99.7 SHC 34.2 46.0 55.8 65.5 34.5 47.0 57.4 67.7 34.9 48.1 59.0 69.8 35.2 49.0 60.5 71.9 GPM 22.0 22.0 22.0 21.6 22.0 22.0 22.0 22.0 22.5 22.5 22.5 22.0 22.5 22.5 22.5 22.5 Table PD-7 — Gross Cooling Capacities SAVE-075 (Cont.) CFM 2700 2925 3150 3375 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 74.7 75.4 78.5 82.5 75.6 76.7 80.3 84.4 76.4 78.0 81.9 86.1 77.2 79.3 83.4 87.6 SHC 62.0 73.0 77.8 81.7 63.0 75.2 79.6 83.6 66.0 77.1 81.2 85.3 68.0 78.5 82.6 86.7 ENT Water Temp (°F) 95 Entering Wet Bulb Temperature (°F) 67 GPM 18.1 18.1 18.5 19.4 18.1 18.5 18.9 19.8 18.1 18.5 19.4 20.3 18.5 18.9 19.8 20.3 TGC 84.1 84.0 84.0 84.3 85.0 84.9 84.9 85.5 85.9 85.8 85.8 86.7 86.6 86.5 86.5 87.9 SHC 47.7 59.4 69.2 78.6 48.9 61.4 71.7 81.4 50.1 63.2 74.1 83.9 51.1 65.0 76.4 86.1 GPM 19.8 19.8 19.8 19.8 19.8 19.8 19.8 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 20.3 TGC 94.0 94.0 93.9 93.8 95.1 95.0 95.0 94.9 96.0 95.9 95.8 95.7 96.8 96.7 96.7 96.6 73 SHC 33.2 44.9 54.6 64.4 33.5 46.0 56.3 66.6 33.8 46.9 57.9 68.8 34.1 47.9 59.4 70.8 GPM 21.6 21.6 21.6 21.6 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.0 22.5 22.5 22.0 22.0 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) Capacity Correction Factor Table Delta T Water (°F) 4.5 7.2 10.0 12.6 15.3 18.0 18 GPM 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. MBh 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. MBh 1.01 1.01 1.00 1.00 1.00 0.99 PKG-PRC007-EN Performance Data Water Cooled 60 Hz Table PD-7 — Gross Cooling Capacities SAVE-075 Metric ENT Water Temp (°C) 24.0 m3/h 4590 4970 5355 5740 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 23.3 23.4 24.2 25.3 23.6 23.8 24.7 25.9 23.8 36.5 25.2 26.5 24.1 24.5 25.7 27.0 SHC 18.8 22.2 23.9 25.1 19.4 22.9 24.5 25.7 20.0 23.5 25.0 26.2 20.6 24.1 25.4 26.7 29.5 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 l/s 1.14 1.14 1.17 1.22 1.14 1.17 1.19 1.25 1.17 1.17 1.22 1.28 1.17 1.19 1.25 1.28 TGC 26.2 26.2 26.1 26.2 26.5 26.5 26.5 26.6 26.8 26.8 26.7 26.9 27.1 27.0 27.0 27.2 SHC 14.6 18.1 21.0 23.8 15.0 18.6 21.7 24.6 15.3 19.2 22.4 25.4 15.7 19.7 23.1 26.2 l/s 1.25 1.25 1.25 1.25 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.31 1.28 1.31 1.31 TGC 29.3 29.3 29.3 29.2 29.7 29.6 29.6 29.6 30.0 29.9 29.9 29.9 30.2 30.2 30.2 30.2 SHC 10.3 13.8 16.6 19.5 10.5 14.1 17.1 20.2 10.6 14.4 17.6 20.8 10.6 14.7 18.1 21.4 l/s 1.39 1.39 1.39 1.39 1.42 1.42 1.39 1.39 1.42 1.42 1.42 1.42 1.42 1.42 1.42 1.42 TGC 22.6 22.8 23.6 24.8 22.9 23.1 24.2 25.3 23.1 23.5 24.6 25.9 23.4 23.9 25.1 26.3 SHC 18.5 21.8 23.4 24.5 19.1 22.5 23.9 25.1 19.7 23.1 24.4 25.6 20.3 23.6 24.9 26.1 l/s 1.14 1.14 1.17 1.22 1.14 1.17 1.19 1.25 1.17 1.17 1.22 1.28 1.17 1.19 1.25 1.28 19.5 TGC 25.4 25.4 25.4 25.4 25.7 25.7 25.7 25.8 26.0 26.0 26.0 26.2 26.2 26.2 26.2 26.5 SHC 14.3 17.8 20.6 23.4 14.6 18.5 21.4 24.2 15.0 18.9 22.1 25.0 15.3 19.4 22.8 25.7 23.0 l/s 1.25 1.25 1.25 1.25 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.31 TGC 28.4 28.4 28.4 28.4 28.8 28.8 28.7 28.7 29.1 29.0 29.0 29.0 29.3 29.3 29.3 29.2 SHC 10.0 13.5 16.3 19.2 10.1 13.8 16.8 19.8 10.2 14.1 17.3 20.5 10.3 14.4 17.7 21.1 l/s 1.39 1.39 1.39 1.36 1.39 1.39 1.39 1.39 1.42 1.42 1.42 1.39 1.42 1.42 1.42 1.42 Table PD-7 — Gross Cooling Capacities SAVE-075 (Cont.) m3/h 4590 4970 5355 5740 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 21.9 22.1 23.0 24.2 22.1 22.5 23.5 24.7 22.4 22.9 24.0 25.2 22.6 23.2 24.4 25.7 SHC 18.2 21.4 22.8 23.9 18.5 22.0 23.3 24.5 19.4 22.6 23.8 25.0 19.9 23.0 24.2 25.4 ENT Water Temp (°C) 35.0 Entering Wet Bulb Temperature (°C) 19.5 l/s 1.14 1.14 1.17 1.22 1.14 1.17 1.19 1.25 1.14 1.17 1.22 1.28 1.17 1.19 1.25 1.28 TGC 24.6 24.6 24.6 24.7 24.9 24.9 24.9 25.1 25.2 25.1 25.1 25.4 25.4 25.3 25.3 25.7 SHC 14.0 17.4 20.3 23.0 14.3 18.0 21.0 23.8 14.7 18.5 21.7 24.6 15.0 19.0 22.4 25.2 l/s 1.25 1.25 1.25 1.25 1.25 1.25 1.25 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 1.28 TGC 27.5 27.5 27.5 27.5 27.9 27.8 27.8 27.8 28.1 28.1 28.1 28.0 28.4 28.3 28.3 28.3 23.0 SHC 9.7 13.2 16.0 18.9 9.8 13.5 16.5 19.5 9.9 13.8 17.0 20.2 10.0 14.0 17.4 20.7 l/s 1.36 1.36 1.36 1.36 1.39 1.39 1.39 1.39 1.39 1.39 1.39 1.39 1.42 1.42 1.39 1.39 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) Capacity Correction Factor Table Delta T Water (°C) 2.5 4.0 5.5 7.0 8.5 10.0 PKG-PRC007-EN l/s 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. kW 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. kW 1.01 1.01 1.00 1.00 1.00 0.99 19 Performance Data Water Cooled 60 Hz Table PD-8 — Gross Cooling Capacities SAVE-100 English ENT Water Temp (°F) 75 CFM 3600 3900 4200 4500 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 109.9 110.1 112.7 117.7 111.2 111.8 115.3 120.5 112.5 113.3 117.6 123.0 113.6 114.8 119.7 125.2 SHC 87.9 103.3 112.7 117.7 90.7 106.8 115.3 120.5 93.4 110.1 117.6 123.0 96.0 113.0 119.7 125.2 85 Entering Wet Bulb Temperature (°F) 73 61 67 GPM 26.0 26.0 26.9 27.8 26.4 26.4 27.3 28.2 26.9 26.9 27.8 28.6 26.9 27.3 28.2 29.5 TGC 122.7 122.6 122.5 122.5 124.2 124.1 124.0 124.1 125.6 125.5 125.3 125.7 126.7 126.6 126.5 127.2 SHC 68.5 84.1 97.1 110.0 70.1 86.7 100.5 114.0 71.7 89.2 103.8 117.8 73.1 91.7 106.9 121.3 GPM 28.6 28.6 28.6 28.6 29.1 29.1 29.1 29.1 29.5 29.5 29.5 29.5 29.5 29.5 29.5 29.5 TGC 136.6 136.5 136.4 136.3 138.2 138.0 137.9 137.8 139.6 139.5 139.4 139.3 140.8 140.7 140.6 140.5 SHC 48.7 64.4 77.4 90.3 49.2 65.8 79.6 93.3 49.6 67.2 81.7 96.2 50.1 68.5 83.7 99.0 GPM 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 32.2 32.2 32.2 32.2 32.6 32.6 32.2 32.2 TGC 106.7 107.1 110.1 115.3 108.0 108.8 112.7 117.9 109.3 110.3 114.9 120.4 110.3 111.9 117.0 122.6 SHC 86.3 101.7 110.1 115.3 89.2 105.1 112.7 117.9 91.9 108.2 114.9 120.4 94.6 110.9 117.0 122.6 GPM 26.0 26.0 26.9 27.8 26.4 26.4 27.3 28.2 26.4 26.9 27.8 28.6 26.9 27.3 28.2 29.5 67 TGC 119.5 119.4 119.3 119.3 120.9 120.7 120.7 120.9 122.2 122.1 122.0 122.5 123.3 123.2 123.1 124.0 SHC 67.1 82.7 95.8 108.6 68.7 85.3 99.1 112.5 70.2 87.9 102.4 116.3 71.8 90.2 105.6 119.7 73 GPM 28.6 28.6 28.6 28.6 29.1 29.1 29.1 29.1 29.1 29.1 29.1 29.5 29.5 29.5 29.5 29.5 TGC 133.2 133.1 133.0 132.9 134.7 134.6 134.5 134.4 136.1 136.0 135.9 135.8 137.3 137.2 137.1 137.0 SHC 47.5 63.1 76.1 89.0 47.9 64.6 78.3 92.0 48.4 65.9 80.4 94.9 48.7 67.3 82.5 97.7 GPM 31.3 31.3 31.3 31.3 31.7 31.7 31.7 31.7 32.2 32.2 31.7 31.7 32.2 32.2 32.2 32.2 Table PD-8 — Gross Cooling Capacities SAVE-100 (Cont.) CFM 3600 3900 4200 4500 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 103.6 104.1 107.6 112.7 105.0 105.8 110.1 115.3 106.1 107.3 112.3 117.6 107.0 109.0 114.3 119.9 SHC 84.9 100.0 107.6 112.7 87.7 103.3 110.1 115.3 90.3 106.2 112.3 117.6 93.0 108.7 114.3 119.9 ENT Water Temp (°F) 95 Entering Wet Bulb Temperature (°F) 67 GPM 26.0 26.0 26.9 27.8 26.4 26.4 27.3 28.2 26.4 26.9 27.8 29.1 26.9 27.3 28.2 29.5 TGC 116.1 116.0 115.9 116.1 117.5 117.4 117.3 117.7 118.8 118.6 118.6 119.3 119.8 119.7 119.6 120.7 SHC 65.6 81.4 94.3 107.0 67.3 83.9 97.6 110.9 68.8 86.4 100.9 114.5 70.4 88.8 104.1 117.8 GPM 28.6 28.6 28.6 28.6 29.1 28.6 28.6 29.1 29.1 29.1 29.1 29.1 29.5 29.5 29.5 29.5 TGC 129.7 129.6 129.5 129.4 131.1 131.0 130.9 130.8 132.5 132.4 132.3 132.2 133.6 133.5 133.4 133.3 73 SHC 46.1 61.8 74.8 87.7 46.7 63.2 76.9 90.6 47.1 64.6 79.1 93.5 47.5 65.9 81.2 96.4 GPM 31.3 31.3 31.3 31.3 31.7 31.7 31.7 31.7 31.7 31.7 31.7 31.7 32.2 32.2 32.2 32.2 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) Capacity Correction Factor Table Delta T Water (°F) 4.5 7.2 10.0 12.6 15.3 18.0 20 GPM 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. MBh 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. MBh 1.01 1.01 1.00 1.00 1.00 0.99 PKG-PRC007-EN Performance Data Water Cooled 60 Hz Table PD-8 — Gross Cooling Capacities SAVE-100 Metric ENT Water Temp (°C) 24.0 m3/h 6120 6630 7140 7650 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 32.2 32.3 33.0 34.5 32.6 32.7 33.8 35.3 33.0 33.2 34.5 36.0 33.3 33.6 35.1 36.7 SHC 25.7 30.3 33.0 34.5 26.6 31.3 33.8 35.3 27.4 32.3 34.5 36.0 28.1 33.1 35.1 36.7 29.5 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 l/s 1.64 1.64 1.70 1.75 1.67 1.67 1.72 1.78 1.70 1.70 1.75 1.81 1.70 1.72 1.78 1.86 TGC 35.9 35.9 35.9 35.9 36.4 36.4 36.3 36.4 36.8 36.8 36.7 36.8 37.1 37.1 37.1 37.3 SHC 20.1 24.7 28.5 32.2 20.6 25.4 29.5 33.4 21.0 26.1 30.4 34.5 21.4 26.9 31.3 35.6 l/s 1.81 1.81 1.81 1.81 1.83 1.83 1.83 1.83 1.86 1.86 1.86 1.86 1.86 1.86 1.86 1.86 TGC 40.0 40.0 40.0 39.9 40.5 40.4 40.4 40.4 40.9 40.9 40.8 40.8 41.3 41.2 41.2 41.2 SHC 14.3 18.9 22.7 26.5 14.4 19.3 23.3 27.3 14.5 19.7 23.9 28.2 14.7 20.1 24.5 29.0 l/s 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.03 2.03 2.03 2.03 2.06 2.06 2.03 2.03 TGC 31.3 31.4 32.3 33.8 31.7 31.9 33.0 34.6 32.0 32.3 33.7 35.3 32.3 32.8 34.3 35.9 SHC 25.3 29.8 32.3 33.8 26.1 30.8 33.0 34.6 26.9 31.7 33.7 35.3 27.7 32.5 34.3 35.9 l/s 1.64 1.64 1.70 1.75 1.67 1.67 1.72 1.78 1.67 1.70 1.75 1.81 1.70 1.72 1.78 1.86 19.5 TGC 35.0 35.0 34.9 34.9 35.4 35.4 35.4 35.4 35.8 35.8 35.7 35.9 36.1 36.1 36.1 36.3 SHC 19.6 24.2 28.1 31.8 20.1 25.0 29.0 33.0 20.6 25.7 30.0 34.1 21.0 26.4 30.9 35.1 23.0 l/s 1.81 1.81 1.81 1.81 1.83 1.83 1.83 1.83 1.83 1.83 1.83 1.86 1.86 1.86 1.86 1.86 TGC 39.0 39.0 39.0 38.9 39.5 39.4 39.4 39.4 39.9 39.8 39.8 39.8 40.2 40.2 40.2 40.1 SHC 13.9 18.5 22.3 26.1 14.0 18.9 22.9 27.0 14.2 19.3 23.6 27.8 14.3 19.7 24.2 28.6 l/s 1.97 1.97 1.97 1.97 2.00 2.00 2.00 2.00 2.03 2.03 2.00 2.00 2.03 2.03 2.03 2.03 Table PD-8 — Gross Cooling Capacities SAVE-100 (Cont.) m3/h 6210 6630 7140 7650 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 30.4 30.5 31.5 33.0 30.8 31.0 32.3 33.8 31.1 31.4 32.9 34.5 31.4 31.9 33.5 35.1 SHC 24.9 29.3 31.5 33.0 25.7 30.3 32.3 33.8 26.5 31.1 32.9 34.5 27.3 31.8 33.5 35.1 ENT Water Temp (°C) 35.0 Entering Wet Bulb Temperature (°C) 19.5 l/s 1.64 1.64 1.70 1.75 1.67 1.67 1.72 1.78 1.67 1.70 1.75 1.83 1.70 1.72 1.78 1.86 TGC 34.0 34.0 34.0 34.0 34.4 34.4 34.4 34.5 34.8 34.7 34.7 34.9 35.1 35.1 35.0 35.4 SHC 19.2 23.8 27.6 31.4 19.7 24.6 28.6 32.5 20.2 25.3 29.6 33.6 20.6 26.0 30.5 34.5 l/s 1.81 1.81 1.81 1.81 1.83 1.81 1.81 1.83 1.83 1.83 1.83 1.83 1.86 1.86 1.86 1.86 TGC 38.0 38.0 37.9 37.9 38.4 38.4 38.4 38.3 38.8 38.8 38.8 38.7 39.1 39.1 39.1 39.1 23.0 SHC 13.5 18.1 21.9 25.7 13.7 18.5 22.5 26.6 13.8 18.9 23.2 27.4 13.9 19.3 23.8 28.2 l/s 1.97 1.97 1.97 1.97 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.00 2.03 2.03 2.03 2.03 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) Capacity Correction Factor Table Delta T Water (°C) 2.5 4.0 5.5 7.0 8.5 10.0 PKG-PRC007-EN l/s 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. kW 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. kW 1.01 1.01 1.00 1.00 1.00 0.99 21 Performance Data Water Cooled 60 Hz Table PD-9 — Gross Cooling Capacities SAVE-125 English ENT Water Temp (°F) 75 CFM 4500 4875 5250 5625 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 135.8 136.1 140.1 146.6 137.3 138.2 143.2 149.9 138.9 140.3 146.2 153.1 140.2 140.7 148.8 155.9 SHC 109.8 129.4 140.1 146.6 113.5 133.7 143.2 149.9 117.0 137.7 146.2 153.1 120.2 140.0 148.8 155.9 85 Entering Wet Bulb Temperature (°F) 73 61 67 GPM 31.3 31.7 32.2 33.5 31.7 31.7 32.6 33.9 32.2 32.2 33.5 34.8 32.2 32.6 33.9 35.2 TGC 151.7 151.6 151.5 151.6 153.6 153.5 153.3 153.7 155.3 155.1 154.9 155.7 156.7 156.5 156.3 157.6 SHC 85.3 105.3 121.8 138.1 87.4 108.6 126.2 143.2 89.4 111.7 130.3 147.9 91.2 114.9 134.3 152.1 GPM 34.4 34.4 34.4 34.4 34.8 34.8 34.8 34.8 35.2 35.2 35.2 35.2 35.2 35.2 35.2 35.7 TGC 169.3 169.1 168.9 168.7 171.3 171.0 170.8 170.7 172.8 172.7 172.6 172.4 174.4 174.2 174.1 174.0 SHC 60.3 80.3 96.8 113.2 60.9 82.0 99.6 117.0 61.5 83.8 102.4 120.8 62.0 85.5 104.9 124.3 GPM 37.9 37.9 37.9 37.9 38.3 38.3 38.3 38.3 38.8 38.8 38.8 38.3 38.8 38.8 38.8 38.8 TGC 131.7 132.3 136.8 143.2 133.2 134.3 139.9 146.5 134.7 136.4 142.7 149.5 136.0 138.5 145.2 152.1 SHC 107.9 127.2 136.8 143.2 111.5 131.4 139.9 146.5 115.0 134.9 142.7 149.5 119.4 138.0 145.2 152.1 GPM 31.3 31.3 32.2 33.5 31.7 31.7 32.6 33.9 31.7 32.2 33.5 34.8 32.2 32.6 33.9 35.2 67 TGC 147.4 147.3 147.1 147.5 149.1 149.3 148.9 149.4 150.7 150.5 150.4 151.4 151.9 151.9 151.7 153.4 SHC 83.5 103.4 119.9 136.1 85.5 107.0 124.3 141.0 87.5 109.8 128.4 145.6 89.4 113.0 132.4 149.7 73 GPM 34.4 34.4 34.4 34.4 34.8 34.8 34.8 34.8 34.8 34.8 34.8 35.2 35.2 35.2 35.2 35.7 TGC 164.4 164.3 164.1 164.0 166.3 166.1 165.9 165.9 167.9 167.7 167.7 167.5 169.4 169.2 169.1 168.9 SHC 58.5 78.4 95.0 111.5 59.1 80.2 97.8 115.3 59.6 82.0 100.5 119.0 60.2 83.7 103.1 122.4 GPM 37.4 37.4 37.4 37.4 37.9 37.9 37.9 37.9 38.3 38.3 38.3 38.3 38.8 38.8 38.8 38.8 Table PD-9 — Gross Cooling Capacities SAVE-125 (Cont.) CFM 4500 4875 5250 5625 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 127.6 128.4 133.4 139.7 129.0 132.6 136.4 142.9 130.3 132.6 139.0 145.8 131.6 134.7 141.5 148.4 SHC 105.9 124.8 133.4 139.7 109.6 128.7 136.4 142.9 113.0 132.0 139.0 145.8 116.2 134.6 141.5 148.4 ENT Water Temp (°F) 95 Entering Wet Bulb Temperature (°F) 67 GPM 31.3 31.3 32.2 33.5 31.3 31.7 33.0 34.4 31.7 32.2 33.5 34.8 32.2 32.6 33.9 35.2 TGC 142.9 142.7 142.6 143.0 144.5 144.4 144.2 145.0 146.0 145.8 145.6 147.0 147.2 147.1 147.0 161.5 SHC 81.6 101.4 118.0 134.0 83.5 104.7 122.3 138.7 85.6 107.9 126.4 143.1 87.5 111.0 130.4 147.0 GPM 33.9 33.9 33.9 34.4 34.4 34.4 34.4 34.8 34.8 34.8 34.8 34.8 34.8 34.8 34.8 35.2 TGC 159.5 159.4 159.2 159.1 161.2 161.0 161.0 160.8 162.8 162.5 162.4 162.2 164.1 163.9 163.8 163.7 73 SHC 56.7 76.7 93.1 109.5 57.3 78.4 96.0 113.4 57.9 80.1 98.7 117.0 58.3 81.8 101.3 120.6 GPM 37.4 37.4 37.4 37.4 37.9 37.9 37.9 37.9 37.9 37.9 37.9 37.9 38.3 38.3 38.3 38.3 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) Capacity Correction Factor Table Delta T Water (°F) 4.5 7.2 10.0 12.6 15.3 18.0 22 GPM 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. MBh 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. MBh 1.01 1.01 1.00 1.00 1.00 0.99 PKG-PRC007-EN Performance Data Water Cooled 60 Hz Table PD-9 — Gross Cooling Capacities SAVE-125 Metric ENT Water Temp (°C) 24.0 m3/h 7650 8285 8920 9560 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 39.8 39.9 41.0 42.9 40.2 40.5 42.0 43.9 40.7 41.1 42.8 44.9 41.1 41.2 43.6 45.7 SHC 32.2 37.9 41.0 42.9 33.3 39.2 42.0 43.9 34.3 40.3 42.8 44.9 35.2 41.0 43.6 45.7 29.5 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 l/s 1.97 2.00 2.03 2.11 2.00 2.00 2.06 2.14 2.03 2.03 2.11 2.20 2.03 2.06 2.14 2.22 TGC 44.5 44.4 44.4 44.4 45.0 45.0 44.9 45.0 45.5 45.4 45.4 45.6 45.9 45.8 45.8 46.2 SHC 25.0 30.9 35.7 40.5 25.6 31.8 37.0 42.0 26.2 32.7 38.2 43.3 26.7 33.7 39.3 44.6 l/s 2.17 2.17 2.17 2.17 2.20 2.20 2.20 2.20 2.22 2.22 2.22 2.22 2.22 2.22 2.22 2.25 TGC 49.6 49.5 49.5 49.4 50.2 50.1 50.1 50.0 50.6 50.6 50.6 50.5 51.1 51.0 51.0 51.0 SHC 17.7 23.5 28.4 33.2 17.8 24.0 29.2 34.3 18.0 24.6 30.0 35.4 18.2 25.0 30.7 36.4 l/s 2.39 2.39 2.39 2.39 2.42 2.42 2.42 2.42 2.45 2.45 2.45 2.42 2.45 2.45 2.45 2.45 TGC 38.6 38.8 40.1 42.0 39.0 39.3 41.0 42.9 39.5 40.0 41.8 43.8 39.8 40.6 42.5 44.6 SHC 31.6 37.3 40.1 42.0 32.7 38.5 41.0 42.9 33.7 39.5 41.8 43.8 35.0 40.4 42.5 44.6 l/s 1.97 1.97 2.03 2.11 2.00 2.00 2.06 2.14 2.00 2.03 2.11 2.20 2.03 2.06 2.14 2.22 19.5 TGC 43.2 43.2 43.1 43.2 43.7 43.7 43.6 43.8 44.1 44.1 44.1 44.4 44.5 44.5 44.5 44.9 SHC 24.5 30.3 35.1 39.9 25.0 31.4 36.4 41.3 25.6 32.2 37.6 42.7 26.2 33.1 38.8 43.9 23.0 l/s 2.17 2.17 2.17 2.17 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.22 2.22 2.22 2.22 2.25 TGC 48.2 48.1 48.1 48.1 48.7 48.7 48.6 48.6 49.2 49.1 49.1 49.1 49.6 49.6 49.5 49.5 SHC 17.1 23.0 27.8 32.7 17.3 23.5 28.6 33.8 17.5 24.0 29.4 34.9 17.6 24.5 30.2 35.9 l/s 2.36 2.36 2.36 2.36 2.39 2.39 2.39 2.39 2.42 2.42 2.42 2.42 2.45 2.45 2.45 2.45 Table PD-9 — Gross Cooling Capacities SAVE-125 (Cont.) m3/h 7650 8285 8920 9560 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 37.4 37.6 39.1 40.9 37.8 38.9 40.0 41.9 38.2 38.9 40.7 42.7 38.5 39.5 41.5 43.5 SHC 31.0 36.6 39.1 40.9 32.1 37.7 40.0 41.9 33.1 38.7 40.7 42.7 34.1 39.4 41.5 43.5 ENT Water Temp (°C) 35.0 Entering Wet Bulb Temperature (°C) 19.5 l/s 1.97 1.97 2.03 2.11 1.97 2.00 2.08 2.17 2.00 2.03 2.11 2.20 2.03 2.06 2.14 2.22 TGC 41.9 41.8 41.8 41.9 42.3 42.3 42.2 42.5 42.8 42.7 42.7 43.1 43.1 43.1 43.1 47.3 SHC 23.9 29.7 34.6 39.3 24.5 30.7 35.8 40.6 25.1 31.6 37.0 41.9 25.6 32.5 38.2 43.1 l/s 2.14 2.14 2.14 2.17 2.17 2.17 2.17 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.20 2.22 TGC 46.7 46.7 46.6 46.6 47.2 47.2 47.2 47.1 47.7 47.6 47.6 47.5 48.1 48.0 48.0 48.0 23.0 SHC 16.6 22.5 27.3 32.1 16.8 23.0 28.1 33.2 17.0 23.5 28.9 34.3 17.1 24.0 29.7 35.3 l/s 2.36 2.36 2.36 2.36 2.39 2.39 2.39 2.39 2.39 2.39 2.39 2.39 2.42 2.42 2.42 2.42 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) Capacity Correction Factor Table Delta T Water (°C) 2.5 4.0 5.5 7.0 8.5 10.0 PKG-PRC007-EN l/s 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. kW 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. kW 1.01 1.01 1.00 1.00 1.00 0.99 23 Performance Data Water Cooled 60 Hz Table PD-10 — Gross Cooling Capacities SAVE-150 English ENT Water Temp (°F) 75 CFM 5400 5850 6300 6750 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 165.6 167.7 175.0 183.4 167.6 170.7 179.0 187.6 169.5 173.8 182.6 191.4 171.2 176.8 185.9 194.9 SHC 138.7 163.2 173.4 181.7 143.7 168.2 177.3 185.8 148.4 172.1 180.9 189.6 152.9 175.1 184.1 193.0 85 Entering Wet Bulb Temperature (°F) 73 61 67 GPM 37.9 38.3 39.6 41.0 38.3 38.8 40.5 41.9 38.3 39.2 41.0 42.7 38.8 40.1 41.9 43.6 TGC 185.4 185.2 185.1 186.5 187.5 187.3 187.3 189.4 189.3 189.2 189.4 192.3 191.0 190.8 191.3 195.1 SHC 106.0 132.7 154.9 175.6 108.8 137.3 160.8 182.0 111.5 141.6 166.4 187.6 114.2 145.9 171.7 192.5 GPM 41.4 41.4 41.4 41.9 41.9 41.9 41.9 42.3 42.3 42.3 42.3 42.7 42.7 42.7 42.7 43.6 TGC 206.9 206.6 206.4 206.3 209.1 208.8 208.6 208.5 210.9 210.8 210.6 210.5 212.7 212.5 212.4 212.2 SHC 72.8 99.4 121.6 143.5 73.5 101.9 125.4 148.8 74.3 104.3 129.2 154.0 74.9 106.6 132.8 158.9 GPM 45.8 45.8 45.8 45.8 46.3 46.3 46.3 46.3 46.7 46.7 46.7 46.7 46.7 46.7 46.7 46.7 TGC 160.4 163.0 170.6 178.8 162.3 166.0 174.4 182.9 164.1 169.2 177.8 186.5 164.1 172.1 180.9 189.8 SHC 136.3 160.0 169.0 177.1 141.2 164.3 172.7 181.2 145.8 167.5 176.1 184.7 150.2 170.5 179.2 188.0 GPM 37.4 37.9 39.6 41.0 37.9 38.8 40.1 41.9 38.3 39.2 41.0 42.7 38.8 39.6 41.4 43.2 67 TGC 179.6 179.3 179.3 181.0 181.3 181.2 181.4 183.9 183.2 183.0 183.4 186.8 184.8 184.6 185.3 189.7 SHC 103.6 130.3 152.4 172.6 106.4 135.1 158.2 178.8 109.1 139.2 163.7 184.0 111.7 143.4 169.0 187.9 73 GPM 41.4 41.4 41.4 41.4 41.4 41.4 41.4 42.3 41.9 41.9 41.9 42.7 42.3 42.3 42.3 43.2 TGC 200.2 200.0 199.9 199.7 202.3 202.1 202.0 201.8 204.1 203.9 203.8 203.7 205.8 205.6 205.4 205.3 SHC 70.4 97.1 119.2 141.2 71.1 99.5 123.0 146.4 71.9 101.9 126.8 151.6 72.6 104.2 130.4 156.5 GPM 45.4 45.4 45.4 45.4 45.8 45.8 45.8 45.8 46.3 45.8 45.8 45.8 46.3 46.3 46.3 46.3 Table PD-10 — Gross Cooling Capacities SAVE-150 (Cont.) CFM 5400 5850 6300 6750 Ent. DB (°F) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 155.0 158.0 165.9 174.0 156.8 161.3 169.6 177.9 158.4 164.3 172.8 181.3 160.0 167.2 175.8 184.5 SHC 133.7 156.2 164.3 172.3 138.5 159.7 168.0 176.2 143.1 162.8 171.2 179.6 147.4 165.6 174.1 182.7 ENT Water Temp (°F) 95 Entering Wet Bulb Temperature (°F) 67 GPM 37.4 37.9 39.6 41.0 37.9 38.8 40.1 41.9 37.9 39.2 41.0 42.3 38.3 39.6 41.4 43.2 TGC 173.4 173.3 173.4 175.4 175.2 175.0 175.4 178.3 176.8 176.7 177.2 181.3 178.3 178.1 179.0 184.5 SHC 101.1 127.8 149.8 169.5 103.9 132.3 155.6 175.0 106.6 136.7 161.0 179.5 109.2 140.9 166.1 182.7 GPM 41.0 41.0 41.0 41.4 41.4 41.4 41.4 41.9 41.4 41.4 41.9 42.3 41.9 41.9 42.3 43.2 TGC 193.4 193.2 193.1 192.9 195.3 195.2 195.0 194.9 197.0 196.9 196.7 196.6 198.6 198.3 198.2 198.0 73 SHC 68.0 94.6 116.8 138.7 68.7 97.1 120.6 144.0 69.5 99.4 124.4 149.1 70.1 101.7 127.9 154.0 GPM 44.9 44.9 44.9 44.9 45.4 45.4 45.4 45.4 45.8 45.8 45.4 45.4 45.8 45.8 45.8 45.8 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) Capacity Correction Factor Table Delta T Water (°F) 4.5 7.2 10.0 12.6 15.3 18.0 24 GPM 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. MBh 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. MBh 1.01 1.01 1.00 1.00 1.00 0.99 PKG-PRC007-EN Performance Data Water Cooled 60 Hz Table PD-10 — Gross Cooling Capacities SAVE-150 Metric ENT Water Temp (°C) 24.0 m3/h 9180 9945 10710 11475 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 48.5 49.1 51.3 53.7 49.1 50.0 52.5 55.0 49.7 50.9 53.5 56.1 50.1 51.8 54.5 57.1 SHC 40.6 47.8 50.8 53.2 42.1 49.3 52.0 54.5 43.5 50.4 53.0 55.6 44.8 51.3 53.9 56.6 29.5 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 l/s 2.39 2.42 2.50 2.58 2.42 2.45 2.56 2.64 2.42 2.47 2.58 2.70 2.45 2.53 2.64 2.75 TGC 54.3 54.3 54.2 54.6 54.9 54.9 54.9 55.5 55.5 55.4 55.5 56.3 56.0 55.9 56.1 57.2 SHC 31.1 38.9 45.4 51.4 31.9 40.2 47.1 53.3 32.7 41.5 48.8 55.0 33.5 42.8 50.3 56.4 l/s 2.61 2.61 2.61 2.64 2.64 2.64 2.64 2.67 2.67 2.67 2.67 2.70 2.70 2.70 2.70 2.75 TGC 60.6 60.5 60.5 60.5 61.3 61.2 61.1 61.1 61.8 61.8 61.7 61.7 62.3 62.3 62.2 62.2 SHC 21.3 29.1 35.6 42.1 21.5 29.9 36.7 43.6 21.8 30.6 37.8 45.1 21.9 31.2 38.9 46.6 l/s 2.89 2.89 2.89 2.89 2.92 2.92 2.92 2.92 2.95 2.95 2.95 2.95 2.95 2.95 2.95 2.95 TGC 47.0 47.7 50.0 52.4 47.6 48.6 51.1 53.6 48.1 49.6 52.1 54.6 48.1 50.4 53.0 55.6 SHC 39.9 46.9 49.5 51.9 41.4 48.1 50.6 53.1 42.7 49.1 51.6 54.1 44.0 49.9 52.5 55.1 l/s 2.36 2.39 2.50 2.58 2.39 2.45 2.53 2.64 2.42 2.47 2.58 2.70 2.45 2.50 2.61 2.72 19.5 TGC 52.6 52.5 52.5 53.0 53.2 53.1 53.2 53.9 53.7 53.6 53.7 54.7 54.1 54.1 54.3 55.6 SHC 30.3 38.2 44.6 50.6 31.2 39.6 46.3 52.4 32.0 40.8 48.0 53.9 32.7 42.0 49.5 55.1 23.0 l/s 2.61 2.61 2.61 2.61 2.61 2.61 2.61 2.67 2.64 2.64 2.64 2.70 2.67 2.67 2.67 2.72 TGC 58.7 58.6 58.6 58.5 59.3 59.2 59.2 59.1 59.8 59.7 59.7 59.7 60.3 60.2 60.2 60.1 SHC 20.6 28.5 34.9 41.4 20.8 29.2 36.0 42.9 21.1 29.9 37.1 44.4 21.3 30.5 38.2 45.9 l/s 2.86 2.86 2.86 2.86 2.89 2.89 2.89 2.89 2.92 2.89 2.89 2.89 2.92 2.92 2.92 2.92 Table PD-10 — Gross Cooling Capacities SAVE-150 (Cont.) m3/h 9180 9945 10710 11475 Ent. DB (°C) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 45.4 46.3 48.6 51.0 45.9 47.3 49.7 52.1 46.4 48.1 50.6 53.1 46.9 49.0 51.5 54.1 SHC 39.2 45.8 48.1 50.5 40.6 46.8 49.2 51.6 41.9 47.7 50.2 52.6 43.2 48.5 51.0 53.5 ENT Water Temp (°C) 35.0 Entering Wet Bulb Temperature (°C) 19.5 l/s 2.36 2.39 2.50 2.58 2.39 2.45 2.53 2.64 2.39 2.47 2.58 2.67 2.42 2.50 2.61 2.72 TGC 50.8 50.8 50.8 51.4 51.3 51.3 51.4 52.2 51.8 51.8 51.9 53.1 52.2 52.2 52.5 54.1 SHC 29.6 37.5 43.9 49.7 30.4 38.8 45.6 51.3 31.2 40.0 47.2 52.6 32.0 41.3 48.7 53.5 l/s 2.58 2.58 2.58 2.61 2.61 2.61 2.61 2.64 2.61 2.61 2.64 2.67 2.64 2.64 2.67 2.72 TGC 56.7 56.6 56.6 56.5 57.2 57.2 57.1 57.1 57.7 57.7 57.6 57.6 58.2 58.1 58.1 58.0 23.0 SHC 19.9 27.7 34.2 40.6 20.1 28.5 35.3 42.2 20.4 29.1 36.4 43.7 20.5 29.8 37.5 45.1 l/s 2.83 2.83 2.83 2.83 2.86 2.86 2.86 2.86 2.89 2.89 2.86 2.86 2.89 2.89 2.89 2.89 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) Capacity Correction Factor Table Delta T Water (°C) 2.5 4.0 5.5 7.0 8.5 10.0 PKG-PRC007-EN l/s 2.21 1.39 1.00 0.79 0.66 0.56 Total Cap. kW 1.01 1.01 1.00 0.99 0.99 0.98 Sens. Cap. kW 1.01 1.01 1.00 1.00 1.00 0.99 25 Performance Data Air Cooled 60 Hz Table PD-11 — Gross Cooling Capacities SRVE-050 English Ambient Temperature (°F) 85 CFM 1800 1950 2100 2250 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 53.7 54.1 56.0 58.6 54.4 54.9 57.2 60.0 55.0 55.8 58.4 61.2 55.5 56.6 59.5 62.3 SHC 44.2 52.0 56.0 58.6 45.7 53.7 57.2 60.0 47.2 55.3 58.4 61.2 48.5 56.6 59.5 62.3 95 Entering Wet Bulb Temperature (°F) 73 61 67 TGC 60.2 60.1 60.1 60.2 61.0 60.8 60.8 61.2 61.5 61.5 61.4 61.9 62.0 62.0 62.0 62.6 SHC 34.1 42.4 49.2 55.8 35.0 43.8 51.0 57.9 35.8 45.1 52.7 59.7 36.6 46.3 54.4 61.4 TGC 67.1 67.0 67.0 66.9 67.8 67.7 67.7 67.6 68.5 68.4 68.4 68.3 69.1 69.0 68.9 71.3 SHC 23.9 32.1 38.9 45.7 24.1 32.9 40.1 47.3 24.3 33.5 41.1 48.8 24.5 34.2 42.3 50.2 TGC 52.2 52.6 54.6 57.2 52.8 53.4 55.9 58.5 53.3 54.3 57.0 59.7 53.8 55.2 58.0 60.8 SHC 43.5 51.2 54.6 57.2 44.9 52.8 55.9 58.5 46.4 54.2 57.0 59.7 47.8 55.2 58.0 60.8 67 TGC 58.4 58.4 58.3 58.5 59.0 59.0 58.9 59.4 59.7 59.6 59.6 60.2 60.2 60.1 60.1 61.0 73 SHC 33.4 41.7 48.4 54.9 34.2 42.9 50.2 56.9 35.1 44.3 51.9 58.7 35.8 45.6 53.5 60.3 Table PD-11 — Gross Cooling Capacities SRVE-050 (Cont.) TGC 65.1 65.1 65.0 65.0 64.6 65.7 65.7 65.6 66.5 66.4 66.3 66.3 67.0 66.9 66.9 66.8 SHC 23.1 31.4 38.2 44.9 23.4 32.1 39.3 46.5 23.6 32.8 40.4 48.0 23.7 33.5 41.6 49.5 English Ambient Temperature (°F) 105 CFM 1800 1950 2100 2250 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 50.6 51.1 53.3 55.8 51.1 51.9 54.5 57.0 51.6 52.9 55.5 58.2 52.2 53.7 56.5 59.1 SHC 42.7 50.2 53.3 55.8 44.2 51.7 54.5 57.0 45.6 52.9 55.5 58.2 47.0 53.7 56.5 59.1 67 TGC 56.6 56.5 56.5 56.7 57.1 57.1 57.1 57.6 57.7 57.7 57.7 58.4 58.2 58.1 58.2 59.3 115 Entering Wet Bulb Temperature (°F) 73 61 SHC 32.6 40.8 47.7 54.1 33.5 42.2 49.4 56.0 34.2 43.5 51.1 57.6 35.1 44.7 52.7 59.0 TGC 63.0 63.0 62.9 62.9 63.6 63.6 63.5 63.5 64.1 64.1 64.0 64.0 64.7 64.7 64.6 64.6 SHC 22.4 30.5 37.4 44.1 22.6 31.3 38.5 45.7 22.8 32.0 39.6 47.3 23.0 32.6 40.7 48.7 TGC 48.9 49.5 51.8 54.3 49.4 50.5 52.9 55.4 49.9 51.4 54.0 56.5 50.4 52.3 54.8 57.5 SHC 42.0 49.2 51.8 54.3 43.4 50.5 52.9 55.4 44.9 51.4 54.0 56.5 46.1 52.3 54.8 57.5 67 TGC 54.6 54.5 54.5 54.9 55.1 55.1 55.1 55.8 55.7 55.5 55.7 56.5 56.1 56.1 56.2 57.5 73 SHC 31.8 40.1 46.9 53.0 32.6 41.3 48.5 54.8 33.5 42.7 50.2 56.3 34.2 43.9 51.8 57.5 TGC 60.6 60.6 60.5 60.5 61.3 61.2 61.2 61.1 61.7 61.7 61.6 61.6 62.2 62.1 62.1 62.0 SHC 21.5 29.8 36.6 43.2 21.7 30.4 37.6 44.8 21.9 31.2 38.8 46.3 22.2 31.8 39.9 47.8 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) 26 PKG-PRC007-EN Performance Data Air Cooled 60 Hz Table PD-11 — Gross Cooling Capacities SRVE-050 Metric Ambient Temperature (°C) 29.5 m3/h 4590 4970 5355 5740 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 22.5 22.6 23.4 24.6 22.7 23.0 24.0 25.1 23.0 23.3 24.5 25.7 23.2 23.7 24.9 26.1 SHC 18.6 21.9 23.4 24.6 19.2 22.6 24.0 25.1 19.8 23.2 24.5 25.7 20.4 23.7 24.9 26.1 19.5 TGC 25.2 25.2 25.1 25.2 25.5 25.4 25.4 25.6 25.7 25.7 25.7 25.9 25.9 25.9 25.9 26.2 35.0 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 14.3 17.8 20.7 23.5 14.7 18.4 21.5 24.3 15.0 18.9 22.2 25.1 15.3 19.5 22.9 25.8 TGC 28.1 28.0 28.0 28.0 28.4 28.4 28.3 28.3 28.6 28.6 28.6 28.6 28.9 28.9 28.8 28.8 SHC 10.0 13.5 16.3 19.2 10.1 13.8 16.8 19.9 10.2 14.1 17.3 20.5 10.2 14.3 17.7 21.1 TGC 21.7 21.9 22.8 23.9 22.0 22.3 23.3 24.5 22.2 22.6 23.8 24.9 22.4 23.0 24.2 25.4 SHC 18.2 21.5 22.8 23.9 18.9 22.1 23.3 24.5 19.4 22.6 23.8 24.9 20.0 23.0 24.2 25.4 19.5 TGC 24.3 24.3 24.3 24.4 24.6 24.6 24.6 24.8 24.8 24.8 24.8 25.1 25.0 25.0 25.0 25.4 23.0 SHC 14.0 17.5 20.3 23.1 14.3 18.0 21.1 23.9 14.7 18.6 21.8 24.6 15.0 19.1 22.5 25.3 Table PD-11 — Gross Cooling Capacities SRVE-050 (Cont.) TGC 27.1 27.1 27.1 27.1 27.4 27.4 27.3 27.3 27.6 27.6 27.6 27.6 27.9 27.8 27.8 27.8 SHC 9.6 13.1 16.0 18.9 9.7 13.4 16.5 19.5 9.8 13.7 16.9 20.2 9.9 14.0 17.4 20.8 Metric Ambient Temperature (°C) 40.5 m3/h 4590 4970 5355 5740 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 20.9 21.2 22.2 23.3 21.2 21.6 22.6 23.8 21.4 22.0 23.1 24.2 21.6 22.3 23.5 24.6 SHC 17.9 21.0 22.2 23.3 18.5 21.6 22.6 23.8 19.1 22.0 23.1 24.2 19.6 22.3 23.5 24.6 19.5 TGC 23.4 23.4 23.4 23.6 23.7 23.7 23.7 23.9 23.9 23.9 23.9 24.3 24.1 24.1 24.1 24.6 46 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 13.6 17.1 20.0 22.7 14.0 17.7 20.7 23.4 14.3 18.2 21.4 24.1 14.6 18.7 22.1 24.6 TGC 26.1 26.1 26.1 26.1 26.4 26.3 26.3 26.3 26.6 26.6 26.6 26.5 26.8 26.8 26.8 26.7 SHC 9.3 12.8 15.6 18.5 9.4 13.0 16.1 19.2 9.4 13.4 16.6 19.8 9.5 13.6 17.0 20.4 TGC 20.1 20.5 21.5 22.5 20.3 20.9 21.9 23.0 20.5 21.2 22.3 23.4 20.7 21.6 22.7 23.8 SHC 17.5 20.4 21.5 22.5 18.1 20.9 21.9 23.0 18.7 21.2 22.3 23.4 19.2 21.6 22.7 23.8 19.5 TGC 22.5 22.5 22.5 22.7 22.7 22.7 22.7 23.0 23.0 22.9 23.0 23.4 23.1 23.1 23.2 23.8 23.0 SHC 13.2 16.7 19.6 22.2 13.6 17.3 20.3 22.9 13.9 17.8 21.0 23.4 14.2 18.3 21.6 23.8 TGC 25.1 25.1 25.0 25.0 25.3 25.3 25.3 25.3 25.5 25.5 25.5 25.5 25.7 25.7 25.7 25.7 SHC 8.9 12.4 15.2 18.1 9.0 12.7 15.7 18.8 9.1 13.0 16.2 19.4 9.2 13.3 16.6 20.0 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) PKG-PRC007-EN 27 Performance Data Air Cooled 60 Hz Table PD-12 — Gross Cooling Capacities SRVE-075 English Ambient Temperature (°F) 85 CFM 2700 2925 3150 3375 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 76.6 77.2 80.0 84.0 77.5 78.4 81.8 85.8 78.3 79.6 83.5 87.6 79.1 80.9 85.0 89.0 SHC 63.5 74.7 80.0 84.0 65.6 77.1 81.8 85.8 67.6 79.2 83.5 87.6 69.5 80.9 85.0 89.0 95 Entering Wet Bulb Temperature (°F) 73 61 67 TGC 85.9 85.9 85.8 86.0 86.9 86.8 86.7 87.2 87.8 87.7 87.7 88.4 88.5 88.5 88.4 89.5 SHC 48.9 60.8 70.7 80.2 50.1 62.8 73.2 83.1 51.3 64.7 75.7 85.6 52.4 66.5 78.0 88.0 TGC 95.8 95.7 95.6 95.5 96.8 96.8 96.7 96.6 97.7 97.6 97.5 97.5 98.5 98.5 98.4 98.3 SHC 34.0 46.0 55.8 65.6 34.5 47.0 57.5 67.8 34.7 48.0 59.0 70.0 35.0 49.0 60.5 72.1 TGC 74.1 74.7 77.9 81.7 74.9 76.0 79.6 83.5 75.7 77.3 81.2 85.1 76.4 78.7 82.6 86.6 SHC 62.2 73.2 77.9 81.7 64.3 75.5 79.6 83.5 66.4 77.3 81.2 85.1 68.3 78.7 82.6 86.6 67 TGC 83.0 83.0 82.9 83.3 84.0 83.8 83.8 84.5 84.8 84.7 84.7 85.6 85.4 85.3 85.4 86.8 73 SHC 47.7 59.6 69.4 78.9 48.9 61.5 72.0 81.6 50.0 63.4 74.4 84.1 51.2 65.2 76.6 86.2 Table PD-12 — Gross Cooling Capacities SRVE-075 (Cont.) TGC 92.5 92.4 92.3 92.3 93.5 93.4 93.3 93.3 94.3 94.2 94.1 94.1 95.1 95.0 94.9 94.9 SHC 32.9 44.7 54.6 64.4 33.2 45.8 56.3 66.7 33.5 46.9 57.8 68.8 33.8 47.8 59.4 70.9 English Ambient Temperature (°F) 105 CFM 2700 2925 3150 3375 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 71.3 72.3 75.7 79.4 72.2 73.7 77.3 81.1 72.9 74.9 78.8 82.6 73.6 76.2 80.1 84.1 SHC 61.0 71.6 75.7 79.4 63.1 73.6 77.3 81.1 65.1 74.9 78.8 82.6 67.0 76.2 80.1 84.1 67 TGC 80.0 79.9 79.8 80.5 80.9 80.8 80.8 81.6 81.6 81.5 81.5 82.8 82.3 82.2 82.3 84.0 115 Entering Wet Bulb Temperature (°F) 73 61 SHC 46.4 58.3 68.2 77.4 47.7 60.3 70.7 79.9 48.8 62.1 73.0 82.2 49.9 63.9 75.3 84.0 TGC 89.1 89.0 88.9 88.9 90.0 89.9 89.9 89.8 90.8 90.7 90.6 90.5 91.5 91.4 91.4 91.3 SHC 31.7 43.6 53.3 63.2 32.0 44.5 55.0 65.4 32.2 45.6 56.6 67.5 32.5 46.5 58.1 69.6 TGC 68.5 69.9 73.4 76.9 69.3 71.2 74.8 78.5 70.0 72.5 76.2 79.9 70.7 73.7 77.5 81.3 SHC 59.7 69.6 73.4 76.9 61.7 71.2 74.8 78.5 63.7 72.5 76.2 79.9 65.5 73.7 77.5 81.3 67 TGC 76.9 76.7 76.7 77.5 77.6 77.5 77.6 78.7 78.3 78.2 78.3 79.9 78.9 78.9 79.1 81.3 73 SHC 45.2 57.0 66.9 75.7 46.3 58.9 69.3 78.0 47.5 60.7 71.7 79.9 48.5 62.5 73.8 81.3 TGC 85.6 85.5 85.4 85.4 86.4 86.3 86.3 86.2 87.1 87.0 87.0 86.9 87.8 87.7 87.6 87.6 SHC 30.4 42.3 52.0 61.9 30.7 43.2 53.7 64.1 31.0 44.3 55.3 66.3 31.3 45.3 56.8 68.3 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) 28 PKG-PRC007-EN Performance Data Air Cooled 60 Hz Table PD-12 — Gross Cooling Capacities SRVE-075 Metric Ambient Temperature (°C) 29.5 m3/h 4590 4970 5355 5740 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 22.5 22.6 23.4 24.6 22.7 23.0 24.0 25.1 23.0 23.3 24.5 25.7 23.2 23.7 24.9 26.1 SHC 18.6 21.9 23.4 24.6 19.2 22.6 24.0 25.1 19.8 23.2 24.5 25.7 20.4 23.7 24.9 26.1 19.5 TGC 25.2 25.2 25.1 25.2 25.5 25.4 25.4 25.6 25.7 25.7 25.7 25.9 25.9 25.9 25.9 26.2 35.0 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 14.3 17.8 20.7 23.5 14.7 18.4 21.5 24.3 15.0 18.9 22.2 25.1 15.3 19.5 22.9 25.8 TGC 28.1 28.0 28.0 28.0 28.4 28.4 28.3 28.3 28.6 28.6 28.6 28.6 28.9 28.9 28.8 28.8 SHC 10.0 13.5 16.3 19.2 10.1 13.8 16.8 19.9 10.2 14.1 17.3 20.5 10.2 14.3 17.7 21.1 TGC 21.7 21.9 22.8 23.9 22.0 22.3 23.3 24.5 22.2 22.6 23.8 24.9 22.4 23.0 24.2 25.4 SHC 18.2 21.5 22.8 23.9 18.9 22.1 23.3 24.5 19.4 22.6 23.8 24.9 20.0 23.0 24.2 25.4 19.5 TGC 24.3 24.3 24.3 24.4 24.6 24.6 24.6 24.8 24.8 24.8 24.8 25.1 25.0 25.0 25.0 25.4 23.0 SHC 14.0 17.5 20.3 23.1 14.3 18.0 21.1 23.9 14.7 18.6 21.8 24.6 15.0 19.1 22.5 25.3 Table PD-12 — Gross Cooling Capacities SRVE-075 (Cont.) TGC 27.1 27.1 27.1 27.1 27.4 27.4 27.3 27.3 27.6 27.6 27.6 27.6 27.9 27.8 27.8 27.8 SHC 9.6 13.1 16.0 18.9 9.7 13.4 16.5 19.5 9.8 13.7 16.9 20.2 9.9 14.0 17.4 20.8 Metric Ambient Temperature (°C) 40.5 m3/h 4590 4970 5355 5740 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 20.9 21.2 22.2 23.3 21.2 21.6 22.6 23.8 21.4 22.0 23.1 24.2 21.6 22.3 23.5 24.6 SHC 17.9 21.0 22.2 23.3 18.5 21.6 22.6 23.8 19.1 22.0 23.1 24.2 19.6 22.3 23.5 24.6 19.5 TGC 23.4 23.4 23.4 23.6 23.7 23.7 23.7 23.9 23.9 23.9 23.9 24.3 24.1 24.1 24.1 24.6 46 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 13.6 17.1 20.0 22.7 14.0 17.7 20.7 23.4 14.3 18.2 21.4 24.1 14.6 18.7 22.1 24.6 TGC 26.1 26.1 26.1 26.1 26.4 26.3 26.3 26.3 26.6 26.6 26.6 26.5 26.8 26.8 26.8 26.7 SHC 9.3 12.8 15.6 18.5 9.4 13.0 16.1 19.2 9.4 13.4 16.6 19.8 9.5 13.6 17.0 20.4 TGC 20.1 20.5 21.5 22.5 20.3 20.9 21.9 23.0 20.5 21.2 22.3 23.4 20.7 21.6 22.7 23.8 SHC 17.5 20.4 21.5 22.5 18.1 20.9 21.9 23.0 18.7 21.2 22.3 23.4 19.2 21.6 22.7 23.8 19.5 TGC 22.5 22.5 22.5 22.7 22.7 22.7 22.7 23.0 23.0 22.9 23.0 23.4 23.1 23.1 23.2 23.8 23.0 SHC 13.2 16.7 19.6 22.2 13.6 17.3 20.3 22.9 13.9 17.8 21.0 23.4 14.2 18.3 21.6 23.8 TGC 25.1 25.1 25.0 25.0 25.3 25.3 25.3 25.3 25.5 25.5 25.5 25.5 25.7 25.7 25.7 25.7 SHC 8.9 12.4 15.2 18.1 9.0 12.7 15.7 18.8 9.1 13.0 16.2 19.4 9.2 13.3 16.6 20.0 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) PKG-PRC007-EN 29 Performance Data Air Cooled 60 Hz Table PD-13 — Gross Cooling Capacities SRVE-100 English Ambient Temperature (°F) 85 CFM 3600 3900 4200 4500 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 107.1 107.7 111.1 116.4 108.6 109.3 113.7 119.0 109.8 110.9 116.0 121.5 110.7 112.6 118.0 123.8 SHC 86.8 102.8 111.1 116.4 89.7 106.4 113.7 119.0 92.5 109.4 116.0 121.5 95.4 112.2 118.0 123.8 67 TGC 120.1 119.9 119.9 120.0 121.5 121.4 121.3 121.6 122.7 122.6 122.5 123.3 123.8 123.7 123.7 124.8 95 Entering Wet Bulb Temperature (°F) 73 61 SHC 66.3 82.8 96.6 110.1 67.9 85.6 100.2 114.1 69.5 88.2 103.6 117.9 71.2 90.7 106.9 121.4 TGC 134.0 133.9 133.7 133.6 135.5 135.4 135.3 135.2 136.8 136.7 136.6 136.5 138.0 137.8 137.7 137.6 SHC 45.5 62.0 75.6 89.4 45.9 63.4 78.0 92.5 46.3 64.9 80.2 95.5 46.8 66.3 82.4 98.4 TGC 103.8 104.4 108.3 113.5 105.1 106.1 110.7 116.1 106.2 107.8 113.0 118.5 107.1 109.4 115.0 120.7 SHC 85.1 100.9 108.3 113.5 88.1 104.3 110.7 116.1 90.9 107.1 113.0 118.5 93.6 109.4 115.0 120.7 67 TGC 116.3 116.2 116.1 116.4 117.6 117.5 117.4 118.0 118.8 118.7 118.6 119.6 119.9 119.8 119.7 121.2 73 SHC 64.6 81.2 94.9 108.3 66.4 85.5 98.5 112.3 68.0 86.5 101.9 116.0 69.5 89.1 105.2 119.4 Table PD-13 — Gross Cooling Capacities SRVE-100 (Cont.) TGC 129.7 129.6 129.5 129.4 131.1 131.0 130.9 130.8 132.3 132.2 132.1 132.0 133.4 133.3 133.2 133.1 SHC 43.8 60.4 74.1 87.7 44.4 61.9 76.4 90.9 44.7 63.3 79.1 94.0 45.1 64.6 80.8 96.9 English Ambient Temperature (°F) 105 CFM 3600 3900 4200 4500 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 100.4 101.2 105.4 110.5 101.6 102.9 107.8 112.9 102.6 104.6 109.9 115.2 103.6 106.4 111.8 117.3 SHC 83.5 99.0 105.4 110.5 86.4 102.0 107.8 112.9 89.3 104.5 109.9 115.2 92.0 106.4 111.8 117.3 67 TGC 112.4 112.3 112.2 112.6 113.6 113.5 113.5 114.2 114.7 114.6 114.6 115.9 115.6 115.5 115.6 117.4 115 Entering Wet Bulb Temperature (°F) 73 61 SHC 63.0 79.6 93.3 106.4 64.6 82.3 96.9 110.3 66.3 84.9 100.3 113.7 67.8 87.4 103.4 116.6 TGC 125.2 125.1 125.0 124.9 126.4 126.3 126.2 83.0 127.6 127.5 127.4 127.3 128.6 128.5 128.4 128.3 SHC 42.2 58.8 72.5 86.1 42.6 60.2 74.8 89.3 43.1 61.6 77.0 92.2 43.5 62.9 79.1 95.2 TGC 96.9 97.9 102.4 107.3 97.9 99.6 104.5 109.5 98.9 101.5 106.5 111.6 99.8 103.1 108.3 113.6 SHC 81.9 96.8 102.4 107.3 84.8 99.5 104.5 109.5 87.5 101.5 106.5 111.6 90.3 103.1 108.3 113.6 67 TGC 108.2 108.1 108.0 108.7 109.3 109.2 109.2 110.3 110.3 110.2 110.2 111.8 111.2 111.1 111.2 113.5 73 SHC 61.3 77.8 91.6 104.3 62.9 80.6 95.0 107.9 64.5 83.1 98.4 111.1 66.1 85.6 101.6 113.5 TGC 120.2 120.1 120.0 119.9 121.4 121.3 121.2 121.1 122.4 122.3 122.2 122.1 123.3 123.2 123.1 123.0 SHC 40.4 57.0 70.6 84.3 40.9 58.4 72.9 87.4 41.2 59.7 75.1 90.4 41.6 61.0 77.3 93.3 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) 30 PKG-PRC007-EN Performance Data Air Cooled 60 Hz Table PD-13 — Gross Cooling Capacities SRVE-100 Metric Ambient Temperature (°C) 29.5 m3/h 6120 6630 7140 7650 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 31.4 31.6 32.5 34.1 31.8 32.0 33.3 34.9 32.2 32.5 34.0 35.6 32.4 33.0 34.6 36.3 SHC 25.4 30.1 32.5 34.1 26.3 31.2 33.3 34.9 27.1 32.1 34.0 35.6 27.9 32.9 34.6 36.3 19.5 TGC 35.2 35.1 35.1 35.2 35.6 35.6 35.5 35.6 36.0 35.9 35.9 36.1 36.3 36.2 36.2 36.6 35.0 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 19.4 24.3 28.3 32.3 19.9 25.1 29.4 33.4 20.4 25.8 30.3 34.6 20.9 26.6 31.3 35.6 TGC 39.3 39.2 39.2 39.2 39.7 39.7 39.6 39.6 40.1 40.0 40.0 40.0 40.4 40.4 40.3 40.3 SHC 13.3 18.2 22.2 26.2 13.4 18.6 22.9 27.1 13.6 19.0 23.5 28.0 13.7 19.4 24.1 28.8 TGC 30.4 30.6 31.7 33.2 30.8 31.1 32.4 34.0 31.1 31.6 33.1 34.7 31.4 32.1 33.7 35.4 SHC 24.9 29.6 31.7 33.2 25.8 30.6 32.4 34.0 26.6 31.4 33.1 34.7 27.4 32.1 33.7 35.4 19.5 TGC 34.1 34.0 34.0 34.1 34.5 34.4 34.4 34.6 34.8 34.8 34.7 35.0 35.1 35.1 35.1 35.5 23.0 SHC 18.9 23.8 27.8 31.7 19.4 25.1 28.9 32.9 19.9 25.4 29.9 34.0 20.4 26.1 30.8 35.0 Table PD-13 — Gross Cooling Capacities SRVE-100 (Cont.) TGC 38.0 38.0 37.9 37.9 38.4 38.4 38.4 38.3 38.8 38.7 38.7 38.7 39.1 39.1 39.0 39.0 SHC 12.8 17.7 21.7 25.7 13.0 18.1 22.4 26.6 13.1 18.6 23.2 27.5 13.2 18.9 23.7 28.4 Metric Ambient Temperature (°C) 40.5 m3/h 6120 6630 7140 7650 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 29.4 29.6 30.9 32.4 29.8 30.1 31.6 33.1 30.1 30.7 32.2 33.8 30.3 31.2 32.8 34.4 SHC 24.5 29.0 30.9 32.4 25.3 29.9 31.6 33.1 26.2 30.6 32.2 33.8 27.0 31.2 32.8 34.4 19.5 TGC 32.9 32.9 32.9 33.0 33.3 33.2 33.2 33.5 33.6 33.6 33.6 33.9 33.9 33.9 33.9 34.4 46 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 18.5 23.3 27.3 31.2 18.9 24.1 28.4 32.3 19.4 24.9 29.4 33.3 19.9 25.6 30.3 34.2 TGC 36.7 36.7 36.6 36.6 37.0 37.0 37.0 24.3 37.4 37.4 37.3 37.3 37.7 37.7 37.6 37.6 SHC 12.4 17.2 21.2 25.2 12.5 17.6 21.9 26.2 12.6 18.0 22.5 27.0 12.7 18.4 23.2 27.9 TGC 28.4 28.7 30.0 31.4 28.7 29.2 30.6 32.1 29.0 29.7 31.2 32.7 29.3 30.2 31.7 33.3 SHC 24.0 28.4 30.0 31.4 24.8 29.2 30.6 32.1 25.6 29.7 31.2 32.7 26.4 30.2 31.7 33.3 19.5 TGC 31.7 31.7 31.6 31.8 32.0 32.0 32.0 32.3 32.3 32.3 32.3 32.8 32.6 32.5 32.6 33.2 23.0 SHC 17.9 22.8 26.8 30.6 18.4 23.6 27.8 31.6 18.9 24.3 28.8 32.5 19.4 25.1 29.8 33.2 TGC 35.2 35.2 35.2 35.1 35.6 35.5 35.5 35.5 35.9 35.8 35.8 35.8 36.1 36.1 36.1 36.0 SHC 11.8 16.7 20.7 24.7 12.0 17.1 21.4 25.6 12.1 17.5 22.0 26.5 12.2 17.9 22.6 27.3 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) PKG-PRC007-EN 31 Performance Data Air Cooled 60 Hz Table PD-14 — Gross Cooling Capacities SRVE-125 English Ambient Temperature (°F) 85 CFM 4500 4875 5250 5625 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 131.7 132.4 137.0 143.3 133.3 134.5 140.0 146.6 134.7 136.5 142.8 149.5 135.9 138.5 145.2 152.1 SHC 108.3 127.7 137.0 143.3 112.0 131.9 140.0 146.6 115.5 135.4 142.8 149.5 118.8 138.3 145.2 152.1 67 TGC 147.0 146.9 146.8 147.1 148.8 148.6 148.5 149.1 150.2 150.1 149.9 151.1 151.6 151.4 151.4 153.0 95 Entering Wet Bulb Temperature (°F) 73 61 SHC 83.5 103.7 120.4 136.5 85.5 107.0 124.7 141.5 87.6 110.0 128.8 146.0 89.5 113.2 132.8 150.0 TGC 163.7 163.5 163.2 163.1 165.3 165.1 165.0 164.9 166.8 166.7 166.5 166.4 168.2 168.0 167.9 167.8 SHC 58.2 78.2 95.0 111.6 58.7 80.1 97.7 115.4 59.3 81.8 100.5 119.1 59.8 83.5 103.1 123.1 TGC 127.4 128.3 133.5 139.6 128.9 130.4 136.3 142.7 130.2 132.6 138.9 145.4 131.3 134.6 141.2 148.0 SHC 110.5 125.2 133.5 139.6 109.9 129.1 136.3 142.7 113.3 132.2 138.9 145.4 116.7 134.6 141.2 148.0 67 TGC 142.3 142.1 141.9 142.5 143.7 143.6 143.5 144.5 145.2 145.0 145.0 146.4 146.4 146.2 146.3 148.4 73 SHC 81.5 101.5 118.4 134.2 83.4 104.8 122.6 139.1 85.5 108.0 126.8 143.2 87.3 111.2 130.7 147.0 Table PD-14 — Gross Cooling Capacities SRVE-125 (Cont.) TGC 158.2 158.0 157.9 157.7 159.7 159.6 159.5 159.4 161.2 161.0 160.9 160.8 162.5 162.3 162.2 162.1 SHC 56.2 76.4 93.1 109.6 56.7 78.1 95.7 113.4 57.2 79.7 98.5 117.1 57.8 81.5 101.1 120.6 English Ambient Temperature (°F) 105 CFM 4500 4875 5250 5625 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 122.9 124.2 129.6 135.7 124.2 126.2 132.3 138.5 125.5 128.5 134.8 141.2 126.6 130.6 137.1 143.6 SHC 104.3 122.4 129.6 135.7 107.8 125.8 132.3 138.5 111.2 128.4 134.8 141.2 114.5 130.6 137.1 143.6 67 TGC 137.3 137.1 137.0 137.7 138.5 138.5 138.3 139.7 139.8 139.8 139.8 141.7 141.0 140.9 141.0 143.7 115 Entering Wet Bulb Temperature (°F) 73 61 SHC 79.3 99.5 116.2 131.8 81.4 102.8 120.4 136.6 83.3 106.0 124.6 140.2 85.2 109.0 128.4 143.2 TGC 152.5 152.3 152.2 152.1 154.0 153.8 153.7 153.6 155.3 155.1 155.0 155.0 156.5 156.2 156.2 156.0 SHC 54.2 74.3 90.8 107.5 54.7 76.1 93.7 111.3 55.2 77.7 96.5 114.9 55.7 79.3 98.9 118.5 TGC 118.3 120.0 125.6 131.5 119.6 122.2 128.2 134.3 120.6 124.3 130.5 136.8 121.7 126.5 132.7 139.1 SHC 102.1 119.4 125.6 131.5 105.6 122.1 128.2 134.3 108.9 124.3 130.5 136.8 112.0 126.5 132.7 139.1 67 TGC 131.9 131.8 131.7 132.8 133.1 133.1 133.1 134.7 134.4 134.3 134.4 136.8 135.4 135.4 135.6 139.1 73 SHC 77.3 97.3 114.1 129.0 79.2 100.6 118.2 133.1 81.2 103.8 122.2 136.3 83.0 106.7 125.9 139.0 TGC 146.5 146.4 146.2 146.2 147.9 147.7 147.7 147.4 149.0 148.9 148.7 148.7 150.1 150.0 149.9 149.7 SHC 52.0 72.1 88.8 105.4 52.6 73.9 91.6 109.2 53.0 75.6 94.2 112.8 53.5 77.2 96.8 116.3 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) 32 PKG-PRC007-EN Performance Data Air Cooled 60 Hz Table PD-14 — Gross Cooling Capacities SRVE-125 Metric Ambient Temperature (°C) 29.5 m3/h 7650 8285 8920 9560 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 38.6 38.8 40.1 42.0 39.1 39.4 41.0 43.0 39.5 40.0 41.8 43.8 39.8 40.6 42.5 44.6 SHC 31.7 37.4 40.1 42.0 32.8 38.6 41.0 43.0 33.9 39.7 41.8 43.8 34.8 40.5 42.5 44.6 35.0 Entering Wet Bulb Temperature (°C) 23.0 16.0 19.5 TGC 43.1 43.0 43.0 43.1 43.6 43.5 43.5 43.7 44.0 44.0 43.9 44.3 44.4 44.4 44.4 44.8 SHC 24.5 30.4 35.3 40.0 25.1 31.3 36.5 41.5 25.7 32.2 37.7 42.8 26.2 33.2 38.9 43.9 TGC 48.0 47.9 47.8 47.8 48.4 48.4 48.4 48.3 48.9 48.9 48.8 48.8 49.3 49.2 49.2 49.2 SHC 17.1 22.9 27.8 32.7 17.2 23.5 28.6 33.8 17.4 24.0 29.4 34.9 17.5 24.5 30.2 36.1 TGC 37.3 37.6 39.1 40.9 37.8 38.2 39.9 41.8 38.1 38.9 40.7 42.6 38.5 39.4 41.4 43.4 SHC 32.4 36.7 39.1 40.9 32.2 37.8 39.9 41.8 33.2 38.7 40.7 42.6 34.2 39.4 41.4 43.4 19.5 TGC 41.7 41.6 41.6 41.7 42.1 42.1 42.1 42.3 42.5 42.5 42.5 42.9 42.9 42.8 42.9 43.5 23.0 SHC 23.9 29.8 34.7 39.3 24.4 30.7 35.9 40.7 25.1 31.6 37.1 42.0 25.6 32.6 38.3 43.1 Table PD-14 — Gross Cooling Capacities SRVE-125 (Cont.) TGC 46.3 46.3 46.3 46.2 46.8 46.8 46.7 46.7 47.2 47.2 47.1 47.1 47.6 47.5 47.5 47.5 SHC 16.5 22.4 27.3 32.1 16.6 22.9 28.0 33.2 16.8 23.4 28.9 34.3 16.9 23.9 29.6 35.3 Metric Ambient Temperature (°C) 40.5 m3/h 7650 8285 8920 9560 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 36.0 36.4 38.0 39.8 36.4 37.0 38.8 40.6 36.8 37.6 39.5 41.4 37.1 38.3 40.2 42.1 SHC 30.6 35.9 38.0 39.8 31.6 36.9 38.8 40.6 32.6 37.6 39.5 41.4 33.5 38.3 40.2 42.1 19.5 TGC 40.2 40.2 40.1 40.3 40.6 40.6 40.5 40.9 41.0 41.0 41.0 41.5 41.3 41.3 41.3 42.1 46 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 23.2 29.2 34.0 38.6 23.9 30.1 35.3 40.0 24.4 31.1 36.5 41.1 25.0 31.9 37.6 42.0 TGC 44.7 44.6 44.6 44.6 45.1 45.1 45.0 45.0 45.5 45.4 45.4 45.4 45.8 45.8 45.8 45.7 SHC 15.9 21.8 26.6 31.5 16.0 22.3 27.5 32.6 16.2 22.8 28.3 33.7 16.3 23.2 29.0 34.7 TGC 34.7 35.2 36.8 38.5 35.0 35.8 37.5 39.3 35.3 36.4 38.2 40.1 35.7 37.1 38.9 40.7 SHC 29.9 35.0 36.8 38.5 30.9 35.8 37.5 39.3 31.9 36.4 38.2 40.1 32.8 37.1 38.9 40.7 19.5 TGC 38.6 38.6 38.6 38.9 39.0 39.0 39.0 39.5 39.4 39.3 39.4 40.1 39.7 39.7 39.7 40.7 23.0 SHC 22.6 28.5 33.4 37.8 23.2 29.5 34.6 39.0 23.8 30.4 35.8 39.9 24.3 31.3 36.9 40.7 TGC 42.9 42.9 42.8 42.8 43.3 43.3 43.3 43.2 43.7 43.6 43.6 43.6 44.0 43.9 43.9 43.9 SHC 15.2 21.1 26.0 30.9 15.4 21.6 26.8 32.0 15.5 22.1 27.6 33.0 15.7 22.6 28.4 34.1 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) PKG-PRC007-EN 33 Performance Data Air Cooled 60 Hz Table PD-15 — Gross Cooling Capacities SRVE-150 English Ambient Temperature (°F) 85 CFM 5400 5850 6300 6750 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 161.0 163.6 171.2 179.2 162.9 166.6 174.9 183.2 164.6 169.8 178.2 186.8 166.2 172.6 181.3 190.0 SHC 135.9 159.3 168.0 175.9 140.7 163.5 171.6 179.7 145.3 166.6 174.8 183.2 149.7 169.3 177.8 186.4 67 TGC 179.6 179.5 179.5 181.2 181.5 181.3 181.5 184.0 183.2 183.0 183.4 186.9 184.5 184.4 185.2 189.8 95 Entering Wet Bulb Temperature (°F) 73 61 SHC 102.9 129.6 151.7 171.8 105.7 134.2 157.5 177.7 108.4 138.4 163.0 182.6 111.0 142.7 168.1 186.3 TGC 199.5 199.4 199.2 199.1 201.5 201.3 201.2 201.1 203.2 203.1 202.9 202.8 204.8 204.6 204.5 204.3 SHC 69.6 96.2 118.2 140.3 70.2 98.6 122.1 145.5 70.9 100.9 125.8 150.6 71.6 103.2 129.4 155.6 TGC 155.3 158.5 166.2 174.2 157.1 161.7 169.7 177.9 158.7 164.6 172.9 181.2 160.3 167.3 175.7 184.2 SHC 133.2 155.3 163.1 170.9 138.0 158.6 166.5 174.5 142.5 161.5 169.6 177.7 146.7 164.1 172.4 180.8 67 TGC 173.1 172.9 173.1 175.2 174.8 174.7 175.0 178.1 176.4 176.2 176.9 181.2 177.8 177.6 178.6 184.1 73 SHC 100.3 127.0 149.0 168.4 103.1 131.5 154.6 173.8 105.8 135.8 160.1 177.7 108.4 140.1 165.0 180.6 Table PD-15 — Gross Cooling Capacities SRVE-150 (Cont.) TGC 192.3 192.1 191.9 191.9 194.1 194.0 193.8 193.7 195.7 195.6 195.4 195.3 197.1 196.9 196.7 196.6 SHC 67.0 93.6 115.8 137.7 67.7 96.0 119.5 142.9 68.3 98.4 123.2 148.0 69.0 100.6 126.9 153.0 English Ambient Temperature (°F) 105 CFM 5400 5850 6300 6750 Ent. DB (ºF) 75 80 85 90 75 80 85 90 75 80 85 90 75 80 85 90 61 TGC 149.2 153.4 161.0 168.8 150.9 156.5 164.3 172.3 152.5 159.2 167.3 175.4 154.0 161.8 170.0 178.3 SHC 130.4 150.5 158.0 165.6 135.1 153.5 161.2 169.0 139.5 156.2 164.1 172.1 143.5 158.7 166.8 174.9 67 TGC 166.3 166.2 166.4 169.1 167.9 167.8 168.3 172.1 169.4 169.2 170.1 175.3 170.7 170.4 171.8 178.2 115 Entering Wet Bulb Temperature (°F) 73 61 SHC 97.7 124.3 146.1 164.5 100.4 128.8 151.6 168.9 103.1 133.1 156.8 172.0 105.7 137.3 161.6 174.8 TGC 184.8 184.5 184.4 184.3 186.5 186.2 186.1 186.0 187.9 187.7 187.6 187.5 189.2 189.0 188.9 188.8 SHC 64.4 91.0 113.0 135.1 65.1 93.4 116.9 140.3 65.7 95.8 120.6 145.4 66.4 98.0 124.2 150.3 TGC 143.1 148.0 155.5 163.0 144.7 150.9 158.6 166.3 146.3 153.6 161.4 169.4 147.7 155.9 164.0 172.0 SHC 127.4 145.2 152.6 160.0 132.0 148.1 155.6 163.2 136.1 150.7 158.4 166.2 140.0 153.0 160.9 168.8 67 TGC 159.3 159.2 159.6 162.9 161.3 160.7 161.5 166.2 162.1 162.0 163.2 169.3 163.2 163.1 164.9 172.0 73 SHC 94.8 121.6 143.1 159.8 97.7 126.0 148.5 163.1 100.3 130.3 153.4 166.1 102.9 134.5 157.9 168.8 TGC 177.0 176.8 176.7 176.6 178.5 178.4 178.2 178.1 179.9 179.7 179.6 179.5 181.0 180.8 180.7 180.7 SHC 61.8 88.4 110.4 132.4 62.4 90.8 114.2 137.6 63.1 93.1 117.9 142.7 63.8 95.3 121.5 147.5 Notes: TGC = Total Gross Capacity (MBh) SHC = Sensible Heat Capacity (MBh) 34 PKG-PRC007-EN Performance Data Air Cooled 60 Hz Table PD-15 — Gross Cooling Capacities SRVE-150 Metric Ambient Temperature (°C) 29.5 m3/h 9180 9945 10710 11475 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 47.2 47.9 50.2 52.5 47.7 48.8 51.2 53.7 48.2 49.8 52.2 54.7 48.7 50.6 53.1 55.7 SHC 39.8 46.7 49.2 51.5 41.2 47.9 50.3 52.7 42.6 48.8 51.2 53.7 43.8 49.6 52.1 54.6 19.5 TGC 52.6 52.6 52.6 53.1 53.2 53.1 53.2 53.9 53.7 53.6 53.7 54.8 54.1 54.0 54.3 55.6 35.0 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 30.1 38.0 44.5 50.3 31.0 39.3 46.1 52.1 31.8 40.6 47.7 53.5 32.5 41.8 49.2 54.6 TGC 58.5 58.4 58.4 58.3 59.0 59.0 58.9 58.9 59.5 59.5 59.4 59.4 60.0 59.9 59.9 59.8 SHC 20.4 28.2 34.6 41.1 20.6 28.9 35.8 42.6 20.8 29.6 36.9 44.1 21.0 30.2 37.9 45.6 TGC 45.5 46.4 48.7 51.0 46.0 47.4 49.7 52.1 46.5 48.2 50.7 53.1 47.0 49.0 51.5 54.0 SHC 39.0 45.5 47.8 50.1 40.4 46.5 48.8 51.1 41.7 47.3 49.7 52.1 43.0 48.1 50.5 53.0 19.5 TGC 50.7 50.7 50.7 51.3 51.2 51.2 51.3 52.2 51.7 51.6 51.8 53.1 52.1 52.0 52.3 53.9 23.0 SHC 29.4 37.2 43.7 49.3 30.2 38.5 45.3 50.9 31.0 39.8 46.9 52.1 31.8 41.0 48.4 52.9 Table PD-15 — Gross Cooling Capacities SRVE-150 (Cont.) TGC 56.3 56.3 56.2 56.2 56.9 56.8 56.8 56.7 57.3 57.3 57.2 57.2 57.7 57.7 57.6 57.6 SHC 19.6 27.4 33.9 40.3 19.8 28.1 35.0 41.9 20.0 28.8 36.1 43.4 20.2 29.5 37.2 44.8 Metric Ambient Temperature (°C) 40.5 m3/h 9180 9945 10710 11475 Ent. DB (ºC) 24 27 29 32 24 27 29 32 24 27 29 32 24 27 29 32 16.0 TGC 43.7 44.9 47.2 49.4 44.2 45.8 48.1 50.5 44.7 46.6 49.0 51.4 45.1 47.4 49.8 52.2 SHC 38.2 44.1 46.3 48.5 39.6 45.0 47.2 49.5 40.9 45.8 48.1 50.4 42.1 46.5 48.9 51.3 19.5 TGC 48.7 48.7 48.8 49.5 49.2 49.2 49.3 50.4 49.6 49.6 49.8 51.4 50.0 49.9 50.3 52.2 46 Entering Wet Bulb Temperature (°C) 23.0 16.0 SHC 28.6 36.4 42.8 48.2 29.4 37.7 44.4 49.5 30.2 39.0 46.0 50.4 31.0 40.2 47.4 51.2 TGC 54.1 54.1 54.0 54.0 54.6 54.6 54.5 54.5 55.1 55.0 55.0 54.9 55.4 55.4 55.3 55.3 SHC 18.9 26.7 33.1 39.6 19.1 27.4 34.3 41.1 19.3 28.1 35.3 42.6 19.4 28.7 36.4 44.0 TGC 41.9 43.4 45.6 47.8 42.4 44.2 46.5 48.7 42.9 45.0 47.3 49.6 43.3 45.7 48.0 50.4 SHC 37.3 42.5 44.7 46.9 38.7 43.4 45.6 47.8 39.9 44.2 46.4 48.7 41.0 44.8 47.1 49.5 19.5 TGC 46.7 46.6 46.8 47.7 47.3 47.1 47.3 48.7 47.5 47.5 47.8 49.6 47.8 47.8 48.3 50.4 23.0 SHC 27.8 35.6 41.9 46.8 28.6 36.9 43.5 47.8 29.4 38.2 44.9 48.7 30.1 39.4 46.3 49.5 TGC 51.9 51.8 51.8 51.7 52.3 52.3 52.2 52.2 52.7 52.6 52.6 52.6 53.0 53.0 53.0 53.0 SHC 18.1 25.9 32.4 38.8 18.3 26.6 33.5 40.3 18.5 27.3 34.6 41.8 18.7 27.9 35.6 43.2 Notes: TGC = Total Gross Capacity (kW) SHC = Sensible Heat Capacity (kW) PKG-PRC007-EN 35 Controls The Genius line offers two Control options: Standard Thermostat or Microprocessor Control. Standard Thermostat All units are supplied with a control thermostat as standard feature. This thermostat can be installed remotely or in the equipment, according to the needs of the client. Microprocessor Control The Microprocessor Control UCP (unit control processor) is factory assembled and tested. It controls unit operation in the independent mode (standalone) or it allows communication when the unit is working in an integrated comfort system (Tracer, Tracer Summit, Tracker). Some of the main advantages and benefits of using the microprocessor are: Great reliability: As we know, this type of control has demonstrated itself to be highly reliable, thus avoiding decalibration or breakdown. Direct digital control: The Integral Proportional Control allows more precise temperature control of the area to be airconditioned. In addition, the temperature sensing instrument is more sensitive than the one used in traditional cases. With this instrument joined to the UCP it is possible to guarantee a setpoint temperature of + - 0.5F. Easy diagnosis: The controller allows the operator to carry out easy and fast test to verify the operation of the unit components (fans and compressors). Low suction pressure during start-up: The controller ignores the low pressurestat information during compressor start-up, thus avoiding that the unit not start because of the low pressure. If after 3 minutes the low pressure is not within the correct range, the unit will deactivate. Elimination of Compressor cycling: The controller allows the compressor to run for a minimum of three minutes, followed by three minutes not running (off) to make sure that there is adequate oil return to the compressor(s). Alternation of Compressor operation: The microprocessor will alternate the compressors according to the number of start-ups and hours of operation of each, 36 so that the degree of wear will be similar for each one. The microprocessor control provides the option for simple and direct communication between the Genius and TRACKER, Tracer or Tracer Summit building administrators. This communication is achieved simply by interconnecting the Genius unit and the building administration system with a twisted pair cable. TRACKER Demand limit: Automatically controls the programmed electricity consumption limits of the setup. This is an important economic factor that makes the cost of the TRACKER insignificant when considered on an annual scale. Record of tendencies: Records up to 192 temperature values during a time frame that you determine. This function makes it possible to do a posterior analysis of the system’s performance. In addition to being able to control the lighting of your house or building, this panel can automatically control up to 12 Genius. It also allows sending air conditioning system alarms to a Maintenance Central 24 hours a day, thus making possible various functions: Record of alarms: The TRACKER immediately identifies any breakdowns in the system, which register as alarms. Besides this, the TRACKER store in its memory up to 32 alarms with information including the date and time of the event. Schedule programming: On the TRACKER you do the annual operating programming of each one of the interconnected sets of equipment with the possibility of setting two different schedules for the initiation and termination of operation for weekdays, weekends and holidays. The objective is to use the equipment only when necessary. There is no need for you to waste energy. Access via telephone line: The TRACKER can be programmed and supervised through the telephone line. It can also, in the same way, send warnings concerning any alarms. Interface with the operator: The TRACKER has a functional keyboard and liquid crystal display that provides the user with a rapid visualization of the system with a minimum of experience. Access is restricted with a safety password. Zoning: When a variable air volume system is controlled, it is capable of independently controlling the temperature of up to 128 different zones, thus optimizing the dimensions of your equipment as well as your investment. Optimized start-up: The TRACKER analyzes the most economical way to turn on the equipment so that you get the desired temperature at the programmed time. This is applicable in setups where various Genius units are interconnected to the control system and, instead of turning on all of them at the same time, they are turned on at different times to avoid peaks in energy consumption. Easy installation: The Genius and the TRACKER leave the factory already programmed and tested. Installation and connection between them is done with a twisted pair. For more details, consult the TRACKER Engineering Bulletin. TRACER SUMMIT This is the controller recommended for very large installations. The Genius’s microprocessor is also able to communicate with the Tracer Summit which provides complete integration of these units with the Integrated Comfort System. Varitrac is the name Trane has given to our variable air volume system for small installations. Airflow through the Genius is constant while the air supply to each zone is variable. So that this will happen, a bypass gate returns airflow that was not required by the zones to the system. The variable air input in each zone is controlled by a VAV box that includes a microprocessor controller. This controller regulates the amount of air needed to maintain the desired temperature. A panel called the Central Control Panel (CCP) is used to program, supervise and control the Varitrac system. Trane personnel can program the TRACKER and the CCP. PKG-PRC007-EN Electrical Data Each unit model has three options for electric heat. The following table shows the options and their capacities in kW. Model Option 1 Option 2 Option 3 5 Ton 2 kW 4 kW 6 kW 7.5 Ton 3 kW 6 kW 9 kW 10 Ton 4 kW 8 kW 2x6 kW 12.5 Ton 5 kW 2x5 kW 2x8 kW 15 Ton 6 kW 2x6 kW 2x9 kW Table ED-1 — Genius – Electrical Features - SRVE/SIVE 050 Nominal Operation Values Fan Voltage STD 220V and 380V Option 1 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum Operation Values Fan Voltage STD 220V and 380V Option 1 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Fan Voltage STD 220V and 380V Option 1 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Compressor KW CNO 15.40 8.92 7.70 15.40 8.92 7.70 15.40 8.92 7.70 4.74 4.74 4.74 Fan Motor KW CNO 3.04 0.83 1.76 1.52 4.14 1.22 2.39 2.07 1.80 0.45 1.04 0.90 Compressor CMO 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 Compressor LRA 128.00 74.10 64.00 128.00 74.10 64.00 128.00 74.10 64.00 Fan Motor CMO 3.80 2.19 1.90 5.18 2.99 1.13 2.25 1.30 1.13 Fan Motor LRA 19.00 11.00 9.50 28.60 16.56 14.30 9.90 5.73 4.95 Fan Motor KW 0.83 0.83 0.83 CNO 3.04 1.76 1.52 3.04 1.76 1.52 3.04 1.76 1.52 Fan Motor CMO 3.80 2.19 1.90 3.80 2.19 1.90 3.80 2.19 1.90 Consumption KW 6.40 6.79 6.02 Current A 21.48 12.44 10.74 22.58 13.07 11.29 20.24 11.72 10.12 Current A 27.50 15.90 13.75 28.88 16.70 12.98 25.95 15.01 12.98 Fan Motor LRA 19.00 11.00 9.50 19.00 11.00 9.50 19.00 11.00 9.50 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option and Option 1 - evaporator fan motor -1 CV. • Option 2 - evaporator fan motor -1.5 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Power of the condenser fan motor -1 CV. • Size the electrical wiring using the maximum operation currents. PKG-PRC007-EN 37 Electrical Data Table ED-2 — Genius – Electrical Features - SRVE/SIVE 050 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Fan STD Option 1 Option 2 Plenum Box Option Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V 220V 380V 440V Compressor KW CNO 18.60 10.77 9.30 18.60 10.77 9.30 18.60 10.77 9.30 18.60 10.77 9.30 6.39 6.39 6.39 6.39 Fan Motor KW CNO 4.14 1.22 2.39 2.07 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 7.32 0.45 1.04 0.90 Compressor CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Compressor LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Fan Motor CMO 5.18 2.99 2.59 6.91 3.99 3.46 9.15 5.28 4.58 2.25 1.30 1.13 Fan Motor LRA 30.92 17.85 15.46 48.36 27.92 24.18 60.45 34.90 30.23 11.25 6.50 5.63 Fan Motor KW 2.23 2.23 2.23 2.23 CNO 7.32 4.23 3.65 7.32 4.23 3.65 7.32 4.23 3.65 7.32 4.23 3.65 Fan Motor CMO 9.15 5.28 4.58 9.15 5.28 4.58 9.15 5.28 4.58 9.15 5.28 4.58 Consumption KW 9.84 10.26 10.85 9.07 Current A 30.06 17.39 15.02 31.45 18.19 15.71 33.24 19.23 16.61 33.24 16.04 13.85 Current A 39.32 22.73 19.66 41.04 23.73 20.52 43.28 25.02 21.64 36.38 21.04 18.19 Fan Motor LRA 60.45 34.90 30.23 60.45 34.90 30.23 60.45 34.90 30.23 60.45 34.90 30.23 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -1.5 CV. • Option 1 - evaporator fan motor -2 CV. • Option 2 - evaporator fan motor -3 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Power of the condenser fan motor -3 CV. • Size the electrical wiring using the maximum operation currents. 38 PKG-PRC007-EN Electrical Data Table ED-3 — Genius – Electrical Features - SRVE/SIVE 100 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Compressor 1 KW CNO 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Fan Compressor 1 LRA 128.00 74.10 64.00 128.00 74.10 64.00 128.00 74.10 64.00 128.00 74.10 64.00 Compressor 1 CMO 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 Compressor 2 LRA 128.00 74.10 64.00 128.00 74.10 64.00 128.00 74.10 64.00 128.00 74.10 64.00 Compressor 2 KW CNO 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 Fan Motor KW CNO 4.14 1.22 2.39 2.07 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 1.80 0.45 1.04 0.90 Compressor 2 CMO 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 Fan Motor CMO 5.18 2.99 2.59 6.91 3.99 3.46 9.15 5.28 4.58 2.25 1.30 1.13 Fan Motor LRA 30.92 17.85 15.46 48.36 27.92 24.18 60.45 34.90 30.23 11.25 6.50 5.63 Fan Motor LRA 60.45 34.90 30.23 60.45 34.90 30.23 60.45 34.90 30.23 60.45 34.90 30.23 Fan Motor KW CNO 7.32 2.23 4.23 3.65 7.32 2.23 4.23 3.65 7.32 2.23 4.23 3.65 7.32 2.23 4.23 3.65 Fan Motor CMO 9.15 5.28 4.58 9.15 5.28 4.58 9.15 5.28 4.58 9.15 5.28 4.58 Consumption KW 12.93 13.35 13.94 12.16 Current A 42.26 24.46 21.12 43.65 25.26 21.81 45.44 26.30 22.71 39.92 23.11 19.95 Current A 54.13 31.31 27.06 55.86 32.31 27.93 58.10 33.60 29.05 51.20 29.62 25.60 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -1.5 CV. • Option 1 - evaporator fan motor -2 CV. • Option 2 - evaporator fan motor -3 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Power of the condenser fan motor -3 CV. • Size the electrical wiring using the maximum operation currents. PKG-PRC007-EN 39 Electrical Data Table ED-4 — Genius – Electrical Features - SRVE/SIVE 125 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Compressor 1 KW CNO 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Fan Compressor 1 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Compressor 1 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Compressor 2 LRA 128.00 99.00 85.50 128.00 99.00 85.50 128.00 99.00 85.50 128.00 99.00 85.50 Compressor 2 KW CNO 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 15.40 4.74 8.92 7.70 Fan Motor KW CNO 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 9.28 2.93 5.36 4.64 1.80 0.45 1.04 0.90 Compressor 2 CMO 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 19.90 11.52 9.95 Fan Motor CMO 6.91 3.99 3.46 9.15 5.28 4.58 11.60 6.70 5.80 2.25 1.30 1.13 Fan Motor LRA 48.36 27.92 24.18 60.45 34.90 30.23 87.00 50.23 43.50 11.25 6.50 5.63 Fan Motor LRA 87.00 50.23 43.50 87.00 50.23 43.50 87.00 50.23 43.50 87.00 50.23 43.50 Fan Motor KW CNO 9.28 2.93 5.36 4.64 9.28 2.93 5.36 4.64 9.28 2.93 5.36 4.64 9.28 2.93 5.36 4.64 Fan Motor CMO 11.60 6.70 5.80 11.60 6.70 5.80 11.60 6.70 5.80 11.60 6.70 5.80 Consumption KW 15.70 16.29 16.99 14.51 Current A 48.81 28.24 24.40 50.60 29.28 25.30 52.56 30.41 26.28 45.08 26.09 22.54 Current A 63.39 36.67 31.69 65.63 37.96 32.81 68.08 39.38 34.04 58.73 33.98 29.36 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -2 CV. • Option 1 - evaporator fan motor -3 CV. • Option 2 - evaporator fan motor -4 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Power of the condenser fan motor -4 CV. • Size the electrical wiring using the maximum operation currents 40 PKG-PRC007-EN Electrical Data Table ED-5 — Genius – Electrical Features - SRVE/SIVE 150 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Compressor 1 KW CNO 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Fan Compressor 1 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Compressor 1 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Compressor 2 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Compressor 2 KW CNO 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 18.60 6.39 10.77 9.30 Fan Motor KW CNO 7.32 2.23 4.23 3.66 9.28 2.93 5.36 4.64 11.61 3.54 6.70 9.30 3.04 0.83 1.76 9.30 Compressor 2 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Fan Motor CMO 9.15 5.28 4.58 11.60 6.70 5.80 14.51 8.38 7.26 3.80 2.19 1.90 Fan Motor LRA 60.45 34.90 30.23 87.00 50.23 43.50 110.55 63.83 55.28 21.96 12.68 10.98 Fan Motor LRA 110.55 63.83 55.28 110.55 63.83 55.28 110.55 63.83 55.28 110.55 63.83 55.28 Fan Motor KW CNO 11.61 3.54 6.70 5.80 11.61 3.54 6.70 5.80 11.61 3.54 6.70 5.80 11.61 3.54 6.70 1.52 Fan Motor CMO 14.51 8.38 7.26 14.51 8.38 7.26 14.51 8.38 7.26 14.51 8.38 7.26 Consumption KW 18.55 19.25 19.86 17.15 Current A 56.13 32.47 28.06 58.09 33.60 29.04 60.42 34.94 30.20 51.85 30.00 25.92 Current A 73.62 42.58 36.82 76.07 44.00 38.04 78.98 45.68 39.50 68.27 39.49 34.14 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -3 CV. • Option 1 - evaporator fan motor -4 CV. • Option 2 - evaporator fan motor -5 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Power of the condenser fan motor -5 CV. • Size the electrical wiring using the maximum operation currents. PKG-PRC007-EN 41 Electrical Data Table ED-6 — Genius – Electrical Features - SAVE 050 Nominal Operation Values Fan Voltage STD 220V and 380V Option 1 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum operation values Fan Voltage STD 220V and 380V Option 1 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up values Fan STD and Option 1 Option 2 Plenum Box Option Compressor KW CNO 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 Compressor CMO 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 09.90 Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V Fan Motor KW CNO 3.04 0.83 1.76 1.52 4.14 1.22 2.39 2.07 1.80 0.45 1.04 0.90 Fan Motor CMO 3.80 2.19 1.90 5.18 2.99 1.90 2.25 1.30 1.13 Compressor LRA 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 Consumption KW 5.00 5.39 4.62 Current A 17.14 9.92 8.57 18.24 10.55 9.12 15.90 9.20 7.95 Current A 23.60 13.65 11.80 24.98 14.45 11.80 22.05 12.76 11.03 Fan Motor LRA 21.96 12.68 10.98 21.96 17.85 10.98 11.25 6.50 5.63 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option and Option 1 - evaporator fan motor -1 CV. • Option 2 - evaporator fan motor -1.5 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Size the electrical wiring using the maximum operation currents. 42 PKG-PRC007-EN Electrical Data Table ED-7 — Genius – Electrical Features - SAVE 075 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum operation values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up values Fan STD Option 1 Option 2 Plenum Box Option Compressor KW CNO 16.99 5.68 9.84 8.50 14.10 5.68 9.84 8.50 14.10 5.68 9.84 8.50 14.10 5.68 9.84 8.50 Compressor CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V 220V 380V 440V Fan Motor KW CNO 4.14 1.22 2.39 2.07 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 1.80 0.45 1.04 0.90 Fan Motor CMO 5.18 2.99 2.59 6.91 3.99 3.46 9.15 5.28 4.58 2.25 1.30 1.13 Compressor LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Consumption KW 6.90 7.32 7.91 6.13 Current A 21.13 12.23 10.57 22.52 13.03 11.26 24.31 14.07 12.16 18.79 10.88 9.40 Current A 30.16 17.45 15.08 31.89 18.45 15.95 34.13 19.74 17.07 27.23 15.76 13.62 Fan Motor LRA 30.92 17.85 15.46 48.36 27.92 24.18 60.45 34.90 30.23 11.25 6.50 5.63 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -1.5 CV. • Option 1 - evaporator fan motor -2 CV. • Option 2 - evaporator fan motor -3 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Size the electrical wiring using the maximum operation currents. PKG-PRC007-EN 43 Electrical Data Table ED-8 — Genius – Electrical Features - SAVE100 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum operation values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up values Fan STD Option 1 Option 2 Plenum Box Option Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V 220V 380V 440V Compressor 1 KW CNO 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 Compressor 1 CMO 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 Compressor 1 LRA 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 Compressor 2 KW CNO 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 Compressor 2 CMO 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 Fan Motor CMO 5.18 2.99 2.59 6.91 3.99 3.46 9.15 5.28 4.58 2.25 1.30 1.13 Compressor 2 LRA 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 Fan Motor KW CNO 4.14 1.22 2.39 2.07 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 1.80 0.45 1.04 0.90 Consumption KW 9.56 9.98 10.57 8.79 Current A 32.34 18.71 16.17 33.73 19.51 16.86 35.52 20.55 17.76 30.00 17.36 15.00 Current A 44.78 25.91 22.39 46.51 26.91 23.26 48.75 28.20 24.38 41.85 24.22 20.93 Fan Motor LRA 30.92 17.85 15.46 48.36 27.92 24.18 60.45 34.90 30.23 11.25 6.50 5.63 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -1.5 CV. • Option 1 - evaporator fan motor -2 CV. • Option 2 - evaporator fan motor -3 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Size the electrical wiring using the maximum operation currents. 44 PKG-PRC007-EN Electrical Data Table ED-9 — Genius – Electrical Features - SAVE125 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Fan STD Option 1 Option 2 Plenum Box Option Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V 220V 380V 440V Compressor 1 KW CNO 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 Compressor 1 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Compressor 1 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Compressor 2 KW CNO 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 14.10 4.17 8.16 7.05 Compressor 2 CMO 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 19.80 11.46 9.90 Fan Motor CMO 6.91 3.99 3.46 9.15 5.28 4.58 11.60 6.70 5.80 2.25 1.30 1.13 Compressor 2 LRA 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 128.00 74.11 64.00 Fan Motor KW CNO 5.53 1.64 3.19 2.76 7.32 2.23 4.23 3.66 9.28 2.93 5.36 4.64 1.80 0.45 1.04 0.90 Consumption KW 11.49 12.08 12.78 10.30 Current A 36.62 21.19 18.31 38.41 22.23 19.21 40.37 23.36 20.19 32.89 19.04 16.45 Current A 51.69 29.91 25.85 53.93 31.20 26.97 56.38 32.62 28.19 47.03 27.22 23.52 Fan Motor LRA 48.36 27.92 24.18 60.45 34.90 24.18 87.00 50.23 43.50 11.25 6.50 5.63 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -2 CV. • Option 1 - evaporator fan motor -3 CV. • Option 2 - evaporator fan motor -4 CV. • Plenum box option - evaporator fan motor -0.5 CV. • Size the electrical wiring using the maximum operation currents. PKG-PRC007-EN 45 Electrical Data Table ED-10 — Genius – Electrical Features - SAVE150 Nominal Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Maximum Operation Values Fan Voltage 220V STD 380V 440V 220V Option 1 380V 440V 220V Option 2 380V 440V Plenum Box 220V Option 380V 440V Start-up Values Fan STD Option 1 Option 2 Plenum Box Option Voltage 220V 380V 440V 220V 380V 440V 220V 380V 440V 220V 380V 440V Compressor 1 KW CNO 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 Compressor 1 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Compressor 1 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Compressor 2 KW CNO 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 16.99 5.68 9.84 8.50 Compressor 2 CMO 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 24.98 14.46 12.49 Fan Motor CMO 9.15 5.28 4.58 11.60 6.70 5.80 14.51 8.38 7.26 3.80 2.19 1.90 Compressor 2 LRA 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 171.00 99.00 85.50 Fan Motor KW CNO 7.32 2.23 4.23 3.66 9.28 2.93 5.36 4.64 11.61 3.54 6.70 5.80 3.04 0.83 1.76 1.52 Consumption KW 13.59 14.29 14.90 12.19 Current A 41.30 23.91 20.66 43.26 25.04 21.64 45.59 26.38 22.80 37.02 21.44 18.52 Current A 59.11 34.20 29.56 61.56 35.62 30.78 64.47 37.30 32.24 53.76 31.11 26.88 Fan Motor LRA 60.45 34.90 30.23 87.00 50.23 43.50 110.55 63.83 55.28 21.96 12.68 10.98 • To know which ventilation option should be used, consult the behavior of the ventilation options. • CNO = Nominal operation current (A). • CMO = Maximum operation current. • LRA = Locked rotor amps. • STD Option - evaporator fan motor -3 CV. • Option 1 - evaporator fan motor -4 CV. • Option 2 - evaporator fan motor -5 CV. • Plenum box option - evaporator fan motor -1 CV. • Size the electrical wiring using the maximum operation currents. 46 PKG-PRC007-EN Dimensions SAVE All dimensions are in 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 (right/left) 09 - Scroll compressor 10 - Drain f 1/2” BSP (left) 11 - Spacing for remote thermostat wire f 46.5 12 - Water intake and outlet (left/right) 13 - Electric panel for electric control model 100/125/150 (optional) 14 - Electric panel 15 - Electric panel for electric control model 050/075 (optional) 16 - Shell and tube condenser Model 050 075 100 125 150 A 38 (960) 47 (1190) 59 (1500) 67 (1700) 67 (1700) PKG-PRC007-EN B 9 (230) 15 (367) 7 (175) 8 (210) 8 (210) C 13 (333) 16 (396) 13 (333) 16 (396) 16 (396) D – – 9 (230) 10 (255) 10 (255) E – – 13 (333) 16 (396) 16 (396) F 16 (397) 17 (427) 17 (429) 17 (443) 17 (443) G 5 (127) 2 (57) 5 (127) 2 (57) 2 (57) H 11 (289) 13 (341) 11 (289) 13 (341) 13 (341) J 10 (263) 10 (263) 8 (213) 8 (213) 8 (213) K 5 (113) 5 (113) 4 (111) 4 (111) 4 (111) øL 1” 1” 1 1/2” 1 1/2” 1 1/2” 47 Dimensions SRVE All dimensions are in 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 (right/left) 09 - Double [intake / exhaust] (condenser) Centrifugal fan 10 - Scroll compressor 11 - Drain f 1/2” BSP (left) 12 - Spacing for remote thermostat wire f 46.5 13 - Electric panel for electric control model 100/125/150 (optional) 14 - Electric panel 15 - Electric panel for electric control model 050/075 (optional) 16 - Shell and tube condenser Model 050 075 100 125 150 48 A 38 (960) 47 (1190) 59 (1500) 67 (1700) 67 (1700) B 9 (230) 15 (367) 7 (175) 8 (210) 8 (210) C 13 (333) 16 (396) 13 (333) 16 (396) 16 (396) D – – 9 (230) 10 (255) 10 (255) E – – 13 (333) 16 (396) 16 (396) F 16 (397) 17 (427) 17 (429) 17 (443) 17 (443) G 5 (127) 2 (57) 5 (127) 2 (57) 2 (57) H 11 (289) 13 (341) 11 (289) 13 (341) 13 (341) J 5 (120) 5 (120) 9 (230) 16 (400) 16 (400) K 47 (1180) 47 (1180) 48 (1210) 50 (1280) 59 (1510) L 10 (258) 10 (258) 10 (247) 9 (240) 9 (240) M 36 (920) 45 (1150) 58 (1460) 65 (1660) 65 (1660) PKG-PRC007-EN Dimensions SIVE All dimensions are in 01 - Plenum box with optional supply screen 02 - Resistor box for heating (optional) (control and power panel for external heating) 03 - Double [intake / exhaust] (evaporator) Centrifugal fan 04 - Supply motor 05 - Evaporating coil 06 - Return screen (optional) 07 - Filters 08 - Spacing for energy intake wire f 46.5 (right/left) 09 - Scroll compressor 10 - Drain f 1/2” BSP (left) 11 - Spacing for remote thermostat wire f 46.5 12 - Electric panel for electric control model 100/125/150 (optional) 13 - Electric panel 14 - Electric panel for electric control model 050/075 (optional) 15 - Prep for spacing for f 46.5 (right/left) lines Model A 050 38 (960) 075 47 (1190) 100 59 (1500) 125 67 (1700) 150 67 (1700) PKG-PRC007-EN B 9 (230) 15 (367) 7 (175) 8 (210) 8 (210) C 13 (333) 16 (396) 13 (333) 16 (396) 16 (396) D – – 9 (230) 10 (255) 10 (255) E – – 13 (333) 16 (396) 16 (396) F 16 (397) 17 (427) 17 (429) 17 (443) 17 (443) G 5 (127) 2 (57) 5 (127) 2 (57) 2 (57) H 11 (289) 13 (341) 11 (289) 13 (341) 13 (341) J – – 6 (150) 6 (150) 6 (150) K – – 8 (205) 8 (205) 8 (205) D1 5/8” 3/4” 5/8” 3/4” 3/4” D2 – – 5/8” 5/8” 3/4” L1 1/2” 1/2” 1/2” 1/2” 1/2” L2 – – 1/2” 1/2” 1/2” 49 CRCB Dimensions All dimensions are in 01 - Double [intake / exhaust] Centrifugal fan 02 - Terminal box 03 - Service panel 04 - Motor 05 - Condensing coil 06 - Spacing for ø 27 energy intake wire 07 - Refrigeration connections (only one setting) Model A 050 39 (987) 075 49 (1241) 100 49 (1341) 125 65 (1646) 150 65 (1646) 50 B C D 25 35 12 (631) (890) (295.5) 25 35 17 (631) (890) (422.5) 25 37 9 (631) (941) (212.5) 28 40 12 (714) (1018) (299.5) 28 49 12 (714) (1247) (299.5) E F 16 – (396) 16 – (396) 13 9 (333) (230) 16 10 (396) (255) 16 10 (396) (255) G – – 13 (333) 16 (396) 16 (396) H 13 (341) 13 (341) 11 (289) 13 (341) 13 (341) I J L 30 28 4 (762) (711) (110) 40 32 4 (1016) (816.5) (110) 45 34 4 (1143) (863.5) (97) 58 37 3 (1473) (940) (84) 58 46 3 (1473) (1168) (84) M 41 (1029) 51 (1283) 55 (1383) 67 (1688) 67 (1688) N 21 (521) 21 (521) 21 (521) 24 (604) 24 (604) P 5 (132) 5 (132) 6 (159) 9 (236) 9 (236) Q – R – ø L1 1/2” ø D1 5/8” ø L2 – ø D2 – – – 1/2” 3/4” – – 8 (200) 8 (200) 8 (200) 10 (255) 10 (255) 10 (255) 1/2” 5/8” 1/2” 5/8” 1/2” 3/4” 1/2” 5/8” 1/2” 3/4” 1/2” 5/8” PKG-PRC007-EN Mechanical Specifications Cabinet Manufactured of galvanized steel plate, it is painted with anticorrosive primer and high resistance synthetic enamel. The cabinet is constructed with an bottom tray, structural laterals, front screen and cover and back cover. The remote condenser cabinet is painted with epoxy primer and high resistance enamel and is also constructed of galvanized steel plate. For frontal access to the evaporator units, just loosen four screws to remove the cover and the screen. Return Screen Screen of anodized aluminum profile with vertical flanges. Vertical screens provide excellent air distribution in the coil. This option is recommended for hulls in which the machine is visible in the zone to be air-conditioned. Plenum Box The style of the plenum box is similar to that of the cabinet and is sized to guarantee silent operation. The plenum box screen has a slight angle that allows the air flow to be directed in a vertical or lateral direction. A specific fan array exists for use of the Genius unit with plenum box (consult the general facts tables). This plenum should only be used when the discharge from the unit is free into the atmosphere. In the case of discharge into a duct network, this option should not be used. PKG-PRC007-EN Coils All the coils (evaporator and condenser) use tubes with 3/8” external diameter and high efficiency aluminum fins, Trane Wavy 3B model, mounted on the evaporator coil with 132 fins per foot, and on the condenser with 168 fins per foot. The copper tubes are expanded mechanically to guarantee perfect contact between fin and tube. All the coils are tested for leaks. Evaporator coils are tested at a pressure of 300 PSIG, and the condensers at 400 PSIG. The tray for condensation water was designed according to the interior air quality standards of ASHRAE. Copper-Copper Coils For applications where greater resistance against corrosion is necessary, coils with copper tubes and fins can be manufactured. Offer as special design. Water-cooled condenser Water-cooled condensers are “Shell and Tube” type. They are manufactured with copper tubes with integrated flanges, expanded in steel mirrors, with grooved holes, mounted in a steel casing and cast iron covers, which are removable for easy cleaning. The casing and covers are protected with finishing paint. Fans Sirocco type centrifugal fans, constructed of galvanized steel plate with static and dynamically balanced rotors. The evaporator array is sized to overcome up to 1.6 inches of external static pressure. Filters The standard unit is furnished with permanent washable filters of electrostatic fabric. Also Available: Metallic permanent filters (standard) Disposable fiberglass filters of 1” thickness Combination in series of the two previous filters Scroll Compressor All compressors of the Genius line are scroll type. They are of high efficiency using ports instead of valves, which eliminates possible breakdowns. They have 64% fewer moveable parts than a reciprocating compressor of the same capacity. Their operation is extremely smooth and silent. Designed, constructed and tested according to ASME standards, for work pressure of 300 PSIG on the refrigerant side and 150 PSIG on the water side. 51 Mechanical Specifications Safety and Protection Devices The equipment is protected by high and low pressure pressurestats with automatic resets and fixed calibration, internal thermostat with automatic reset in the compressor, current overload relay for the compressor and overload thermal relay for the fan motors. Water-cooled condensers are protected by a fusible top. Regulating points for high and low pressure pressurestats Machines with water condensation Machines with air condensation Machines with water and air condensation Cooling Components In the suction and discharge lines Rotalock type service valves are available. The liquid line has a 1/4” SAE Schrader valve. A drying filter is installed in the liquid line. For the SIVE model the drying filter Line diameter 5 TR circuit 7.5 TR circuit 10 TR circuit Suction line 7/8” 1 1/8” 1 1/8” Controls Units are provided with a control thermostat. This thermostat can be installed remotely or in the equipment, depending on the needs of the client. As Option: Programmable Thermostat UCP Microprocessor Control Service Valve Service valve for the liquid line. Condensation Pressure Controller A set with pressurestatic valves to control the condensation pressure in machines with air-cooled condensers. The Trane Company 3600 Pammel Creek Road La Crosse, WI 54601-7599 www.trane.com An American Standard Company Stop - PSIG 275 +/- 15 395 +/- 15 25 +/- 8 Start-up - PSIG 185 +/-15 280 +/- 20 80 +/- 12 has a screw connection. For the SAVE and SRVE models, the filter is welded. The following table shows the refrigerant tube diameters relative to the equipment cooling circuits. Discharge line 5/8” 3/4” 7/8” Liquid line 1/2” 1/2” 5/8” Electric Heating Includes heating resistors, stainless steel tubes, a contact unit, fuses, a control thermostat and safety thermostat, all properly installed. The control scheme considers the use of heating resistors. Tests Genius line equipment are shipped fully tested from the factory. The standard tests consist of visual inspections, leak tests, fan start-up followed by start-up and operation of the unit. Trane offers the following factory tests: Basic production test with inspector. Performance test. Complete test with or without an inspector present. High pressure pressurestat with manual reset Liquid Tank Only for the SIVE model. Liquid Viewer Auxiliary maintenance component, indicates the existence of humidity inside the equipment. Solenoid Valve Auxiliary component that allows confinement of the refrigerant in the condenser for later extraction. Supply Voltage 220V, 380V, 440V, triphasics, 60 Hz. Literature Order Number PKG-PRC007-EN File Number PL-UN-PKG-000-PRC007-EN-100 Supersedes New Stocking Location La Crosse Since The Trane Company has a policy of continuous product improvement, it reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V1.2 (40-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Assemble, Print high-res Create Date : 1910:00:12 51:50:05 Producer : Acrobat Distiller 3.01 for Windows Author : Administrator Creator : PageMaker 6.5 Title : Genius(TM) Air and Water Cooled, 5 - 15 Tons, 60 Hz, PDF Product Catalog (PKG-PRC007-EN) Modify Date : 2000:06:12 15:26:24-05:00 Page Count : 52 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools