Trane Series R Helical Rotary Rtac Catalogue RLC PRC006M EN (01/2015)
2015-04-02
: Trane Trane-Series-R-Helical-Rotary--Rtac-Catalogue-684180 trane-series-r-helical-rotary--rtac-catalogue-684180 trane pdf
Open the PDF directly: View PDF .
Page Count: 82
Download | |
Open PDF In Browser | View PDF |
Product Catalog Air-Cooled Series R™ Chillers Model RTAC 140 to 500 nominal tons (60 Hz) January 2015 RLC-PRC006M-EN Introduction Like its chillers,Trane wants its relationships with customers to last.Trane is interested in maintaining long term, loyal relationships.This perspective means the point in time that a customer purchases a chiller is the beginning of a relationship, not the end.Your business is important, but your satisfaction is paramount. The RTAC offers high reliability coupled with proven Series R performance. The Series R Model RTAC is an industrial grade design built for both the industrial and commercial markets. It is ideal for schools, hospitals, retailers, office buildings, Internet service providers and manufacturing facilities. Copyright This document and the information in it are the property ofTrane, and may not be used or reproduced in whole or in part without written permission.Trane reserves the right to revise this publication at any time, and to make changes to its content without obligation to notify any person of such revision or change. Trademarks All trademarks referenced in this document are the trademarks of their respective owners. Revision History RLC-PRC006M-EN (15 Jan 2015) The following points describe the changes to this revision on the manual: • Updated electrical data and customer wiring information • Rapid RestartTest • Add seismic isolator option • Added optional tarp information © 2015Trane All rights reserved RLC-PRC006M-EN Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Application Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Model Number Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 General Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Electrical Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Mechanical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 76 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 RLC-PRC006M-EN 3 Features and Benefits World Class Energy Efficiency The importance of energy efficiency cannot be understated. Fortunately, ASHRAE has created a guideline emphasizing its importance. Nonetheless, energy is often dismissed as an operational cost over which the owner has little control.That perception results in missed opportunities for energy efficiency, reduced utility bills, and higher profits. Lower utility bills directly affect profitability. Every dollar saved in energy goes directly to the bottom line.Trane's RTAC is one way to maximize your profits. ASHRAE Standard 90.1 and Executive Order AllTrane air-cooled chillers meet the new efficiency levels mandated by ASHRAE Standard 90.1. This new standard requires higher efficiencies than past technologies can deliver.The US Federal Government has adopted standard 90.1 and, in some cases, requires even higher efficiencies. Federal Executive Order mandates energy consuming devices procured must be in the top 25% of their class. In the case of chillers, that product standard is ASHRAE 90.1.Trane's RTAC meets and exceeds the efficiency requirements of 90.1, while the high and extra efficiency RTAC can meet the "stretch goals" of Executive Order. Precise Capacity Control Trane's patented unloading system allows the compressor to modulate infinitely and exactly match building loads. At the same time chilled water temperatures will be maintained within +/- 1/2ºF (0.28°C) of setpoint. Screw or scroll chillers with stepped capacity control do well to maintain chilled water temperatures within 2ºF (1.1°C) of setpoint. Stepped control also results in over cooling because rarely does the capacity of the machine match the building load.The result can be 10% higher energy bills.Trane's RTAC optimizes the part load performance of your machine for energy efficiency, precise control for process applications, and your personal comfort regardless of the weather outside. Excellent Reliability A buildings environment is expected to be comfortable. When it is, no one says a word. If it's not… that's a different story.The same is true with chillers. No one ever talks about chillers, yet alone compressors, until they fail, and tenants are uncomfortable and productivity is lost.Trane's helical rotary compressors have been designed and built to stay running when you need them. Fewer moving parts Trane's helical rotary compressors have only two major rotating parts: the male and female rotor. A reciprocating compressor can have more than 15 times that number of critical parts. Multiples of pistons, valves, crankshafts, and connecting rods in a reciprocating unit all represent different failure paths for the compressor. In fact, reciprocating compressors can easily have a failure rate four times of a helical rotor. Combine that with two to three reciprocating compressors for each helical rotary compressor on chillers of equal tonnage, and statistics tell you it's a matter of time before you lose a reciprocating compressor. Robust components Helical rotary compressors are precisely machined using state of the art processes from solid metal bar stock.Tolerances are maintained within a micron or less than a tenth of the diameter of a human hair.The resulting compressor is a robust yet highly sophisticated assembly capable of ingesting liquid refrigerant without risk of damage. 4 RLC-PRC006M-EN Features and Benefits Condenser coils Trane's condenser coils are manufactured with the same philosophy as the compressors; they're built to last. Even though manufacturing processes have allowed thinner and thinner materials in their assembly, with obvious material and manufacturing savings,Trane's coil material did not change with the RTAC generation of air cooled chillers. Substantial condenser fins, that do not require additional coating in non-corrosive environments, contribute to the highest reliability standards for air-cooled chillers in the industry. Superior Control The Adaptive Control™ microprocessor system enhances the air-cooled Series R chiller by providing the very latest chiller control technology. With the Adaptive Control microprocessor, unnecessary service calls and unhappy tenants are avoided.The unit is designed not to trip or unnecessarily shut down. Only when theTracer™ chiller controllers have exhausted all possible corrective actions and the unit is still violating an operating limit will the chiller shut down. Controls on other equipment typically shut down the chiller, usually just when it is needed the most. For example: A typical five year old chiller with dirty coils might trip out on high pressure cutout on a 100°F (38°C) day in August. A hot day is just when comfort cooling is needed the most. In contrast, the air-cooled Series R chiller with an Adaptive Control microprocessor will stage fans on, modulate electronic expansion valves, and modulate slide valve positions as the chiller approaches a high pressure cutout, thereby keeping the chiller online when you need it the most. Simple Installation RLC-PRC006M-EN • Factory Installed Flow Switch. Installed in the optimum location in the piping for reduced chiller installation cost and superior flow sensing, reducing the potential for nuisance trips. • Close Spacing Installation.The air-cooled Series R™ Chiller has the tightest recommended side clearance in the industry, four feet for maximum performance. In situations where equipment must be installed with less clearance than recommended, which frequently occurs in retrofit applications, restricted airflow is common. Conventional chillers may not work at all. However, the air-cooled Series R chiller with Adaptive Control™ microprocessor will make as much chilled water as possible given the actual installed conditions, stay on line during unforeseen abnormal conditions, and optimize the unit performance. Consult yourTrane sales engineer for more details. • Factory Testing Means Trouble Free Startup. All air-cooled Series R chillers are given a complete functional test at the factory.This computer based test program completely checks the sensors, wiring, electrical components, microprocessor function, communication capability, expansion valve performance and fans. In addition, each compressor is run and tested to verify capacity and efficiency. Where applicable, each unit is factory preset to the customer's design conditions; an example would be leaving liquid temperature setpoint.The result of this test program is that the chiller arrives at the job site fully tested and ready for operation. • Factory Installed and Tested Controls/Options Speed Installation. All Series R chiller options, including main power supply disconnect, low ambient control, ambient temperature sensor, low ambient lockout, communication interface and ice making controls, are factory installed and tested. Some manufacturers send accessories in pieces to be field installed. With Trane, the customer saves on installation expense and has assurance that ALL chiller controls/ options have been tested and will function as intended. 5 Features and Benefits Unit Performance Testing The AHRI Certification Program has had a certification program covering air-cooled water chillers for many years. With this in mind, customers may ask, "Do I need to factory performance test my chiller?" Trane began promoting factory performance tests for water-cooled water chillers in 1984 for the same reasons it is valid today for air-cooled water chillers, to show we stand behind the products we design and build. The benefits of a performance test include verification of performance, prevention of operational problems, and assurance of a smooth startup. Only a performance test conducted in a laboratory or laboratory grade facility will confirm both performance and operation of a specific chiller. While most factory performance tests go smoothly, should problems occur,Trane personnel can quickly correct them and the chiller will ship as specified. Job site diagnosis, ordering of parts, and waiting for delivery of replacement components is significantly reduced. A factory performance test reduces startup time, thereby saving job site expense. A chiller that has been tested is operation and performance proven.This allows the installing contractor to concentrate on proper electrical wiring and water piping, and the service technicians to concentrate on proper refrigerant charge, safeties diagnosis and initial logging of the chiller. Means of obtaining full load on the chiller and proving its performance do not have to be determined by engineers or contractors, thus saving time.The certified test report documents performance for the unit as built. In addition, factory testing significantly reduces commissioning time and risk by reintroducing manufacturer responsibility, where its mitigation should reside. When a factory performance test is requested, the test can be conducted at the specified design conditions for all packaged chillers.The test facility has the capability to control ambient test conditions to assure our customers that our chillers will perform as predicted. Rapid Restart™ testing is also available to demonstrate the chiller’s rapid restart capabilities for disaster relief.While the chiller is operating at customer specified full load conditions, power to the chiller is cut and the customer can witness how quickly the chiller will return to full load. For more information on test performance testing, see brochure RL-SLB012-EN. 6 RLC-PRC006M-EN Application Considerations Important Certain application constraints should be considered when sizing, selecting and installingTrane aircooled Series R chillers. Unit and system reliability is often dependent upon proper and complete compliance with these considerations.When the application varies from the guidelines presented, it should be reviewed with your localTrane sales engineer. Unit Sizing Unit capacities are listed in the performance data section. Intentionally over sizing a unit to assure adequate capacity is not recommended. Erratic system operation and excessive compressor cycling are often a direct result of an oversized chiller. In addition, an oversized unit is usually more expensive to purchase, install, and operate. If over sizing is desired, consider using multiple units. Water Treatment Dirt, scale, products of corrosion and other foreign material will adversely affect heat transfer between the water and system components. Foreign matter in the chilled water system can also increase pressure drop and consequently, reduce water flow. Proper water treatment must be determined locally, depending on the type of system and local water characteristics. Neither salt nor brackish water is recommended for use inTrane air-cooled Series R chillers. Use of either will lead to a shortened life to an indeterminable degree.TheTrane Company encourages the employment of a reputable water treatment specialist, familiar with local water conditions, to assist in this determination and in the establishment of a proper water treatment program. Effect Of Altitude On Capacity Air-cooled Series R chiller capacities given in the performance data tables are for use at sea level. At elevations substantially above sea level, the decreased air density will reduce condenser capacity and, therefore, unit capacity and efficiency. Ambient Limitations Trane air-cooled Series R chillers are designed for year round operation over a range of ambient temperatures.The Model RTAC chiller will operate as standard in ambient temperatures of 25°F to 115°F (-4°C to 46°C). With the low ambient option, these units will operate down to 0°F (-18°C). If an ambient temperature as high as 125°F (51°C) is the basis for design, the high ambient option will permit the chiller to run without going into a limiting condition. For installations in areas with large ambient differences, the wide ambient option will allow the chiller to perform uninhibited from 0°F to 125°F (-18°C to 51°C). Water Flow Limits The minimum and maximum water flow rates are given in the General Data tables. Evaporator flow rates below the tabulated values will result in laminar flow causing freeze up problems, scaling, stratification and poor control. Flow rates exceeding those listed may result in excessive tube erosion. Note: Flow rates in General Data tables are for water only.They do not include glycol. Leaving Water Temperature Limits Trane air-cooled Series R chillers have three distinct leaving water categories: standard, low temperature, and ice making.The standard leaving solution temperature range is 40 to 65°F (4.4 to 15.6°C). Low temperature machines produce leaving liquid temperatures less than 40°F (4.4°C). Since liquid supply temperature setpoints less than 40°F (4.4°C) result in suction temperatures at or below the freezing point of water, a glycol solution is required for all low temperature machines. Ice making machines have a leaving liquid temperature range of 20 to 60°F (-6.7 to 15.6°C). Ice making controls include dual setpoint controls and safeties for ice making and standard cooling capabilities. Consult your localTrane sales engineer for applications or selections involving low RLC-PRC006M-EN 7 Application Considerations temperature or ice making machines.The maximum water temperature that can be circulated through an evaporator when the unit is not operating is 108°F (42°C). Flow Rates Out of Range Many process cooling jobs require flow rates that cannot be met with the minimum and maximum published values for the Model RTAC evaporator. A simple piping change can alleviate this problem. For example: A plastic injection molding process requires 80 gpm (5.1 l/s) of 50°F (10°C) water and returns that water at 60°F (15.6°C).The selected chiller can operate at these temperatures, but has a minimum flow rate of 120 gpm (7.6 l/s).The system layout in Figure A1 can satisfy the process. Figure 1. Flow rate out of range system layout Flow Control Trane requires the chilled water flow control in conjunction with the Air-Cooled Series R Chiller to be done by the chiller.This will allow the chiller to protect itself in potentially harmful conditions. Supply Water Temperature Drop The performance data for theTrane air-cooled Series R chiller is based on a chilled water temperature drop of 10°F (5.6°C). Chilled water temperature drops from 6 to 18°F (3.3 to 10°C) may be used as long as minimum and maximum water temperatures and flow rates are not violated. Temperature drops outside this range are beyond the optimum range for control and may adversely affect the microcomputer's ability to maintain an acceptable supply water temperature range. Further, temperature drops of less than 6°F (3.3°C) may result in inadequate refrigerant superheat. Sufficient superheat is always a primary concern in any refrigerant system and is especially important in a package chiller where the evaporator is closely coupled to the compressor.When temperature drops are less than 6°F (3.3°C), an evaporator runaround loop may be required. Leaving Water Temperature Out of Range Many process cooling jobs require temperature ranges that cannot be met with the minimum and maximum published values for the Model RTAC evaporator. A simple piping change can alleviate this problem. For example: A laboratory load requires 120 gpm (7.6 l/s) of water entering the process at 85°F (29.4°C) and returning at 95°F (35°C).The accuracy required is better than the cooling tower can give.The selected chiller has adequate capacity, but a maximum leaving chilled water temperature of 60°F (15.6°C). In Figure A2, both the chiller and process flow rates are equal.This is not necessary. For example, if the chiller had a higher flow rate, there would simply be more water bypassing and mixing with warm water. 8 RLC-PRC006M-EN Application Considerations Figure 2. Temperature out of range system layout Variable Flow in the Evaporator An attractive chilled water system option may be a variable primary flow (VPF) system. VPF systems present building owners with several cost saving benefits that are directly related to the pumps.The most obvious cost savings result from eliminating the secondary distribution pump, which in turn avoids the expense incurred with the associated piping connections (material, labor), electrical service, and variable frequency drive. Building owners often cite pump related energy savings as the reason that prompted them to install a VPF system. The evaporator on the Model RTAC can withstand up to 50 percent water flow reduction as long as this flow is equal to or above the minimum flow rate requirements.The microprocessor and capacity control algorithms are designed to handle a maximum of 10% change in water flow rate per minute in order to maintain ± 0.5°F (0.28°C) leaving evaporator temperature control. For applications in which system energy savings is most important and tight temperature control is classified as +/- 2°F (1.1°C), up to 30 percent changes in flow per minute are possible. With the help of a software analysis tool such as System Analyzer™, DOE-2 orTRACE™, you can determine whether the anticipated energy savings justify the use of variable primary flow in a particular application. It may also be easier to apply variable primary flow in an existing chilled water plant. Unlike the "decoupled" system design, the bypass can be positioned at various points in the chilled water loop and an additional pump is unnecessary. Series Chiller Arrangements Another energy saving strategy is to design the system around chillers arranged in series.The actual savings possible with such strategies depends on the application dynamics and should be researched by consulting yourTrane Systems Solutions Representative and applying an analysis tool from theTrace software family. It is possible to operate a pair of chillers more efficiently in a series chiller arrangement than in a parallel arrangement. It is also possible to achieve higher entering to leaving chiller differentials, which may, in turn, provide the opportunity for lower chilled water design temperature, lower design flow, and resulting installation and operational cost savings.TheTrane screw compressor also has excellent capabilities for “lift,” which affords an opportunity for “lift,” which affords an opportunity for savings on the evaporator water loop. Series chiller arrangements can be controlled in several ways. Figure A3 shows a strategy where each chiller is trying to achieve the system design set point. If the cooling load is less than 50 percent of the systems capabilities, either chiller can fulfill the demand. As system loads increase, the Chiller 2 becomes preferentially loaded as it attempts to meet the leaving chilled water setpoint. Chiller 1 will finish cooling the leaving water from Chiller 2 down to the system design setpoint. RLC-PRC006M-EN 9 Application Considerations Staggering the chiller set points is another control technique that works well for preferentially loading Chiller 1. If the cooling load is less than 50 percent of the system capacity, Chiller 1 would be able to satisfy the entire call for cooling. As system loads increase, Chiller 2 is started to meet any portion of the load that Chiller 1 can not meet. Figure 3. Typical series chiller arrangement Typical Water Piping All building water piping must be flushed prior to making the final connections to the chiller.To reduce heat loss and prevent condensation, insulation should be installed. Expansion tanks are also usually required so that chilled water volume changes can be accommodated. Short Water Loops The proper location of the temperature control sensor is in the supply (outlet) water connection or pipe.This location allows the building to act as a buffer and assures a slowly changing return water temperature. If there is not a sufficient volume of water in the system to provide an adequate buffer, temperature control can be lost, resulting in erratic system operation and excessive compressor cycling. A short water loop has the same effect as attempting to control from the building return water.Typically, a two minute water loop is sufficient to prevent problems.Therefore, as a guideline, ensure the volume of water in the evaporator loop equals or exceeds two times the evaporator flow rate in gallons per minute. For a rapidly changing load profile, the amount of volume should be increased.To prevent the effect of a short water loop, the following items should be given careful consideration: A storage tank or larger header pipe to increase the volume of water in the system and, therefore, reduce the rate of change of the return water temperature. ApplicationsTypes 10 • Comfort cooling. • Industrial process cooling. • Ice/thermal storage. • Low temperature process cooling. RLC-PRC006M-EN Application Considerations Typical Unit Installation Outdoor HVAC equipment must be located to minimize noise and vibration transmission to the occupied spaces of the building structure it serves. If the equipment must be located in close proximity to a building, it could be placed next to an unoccupied space such as a storage room, mechanical room, etc. It is not recommended to locate the equipment near occupied, sound sensitive areas of the building or near windows. Locating the equipment away from structures will also prevent sound reflection, which can increase levels at property lines, or other sensitive points. When physically isolating the unit from structures, it is a good idea to not use rigid supports, and to eliminate any metal-to-metal or hard material contact, when possible.This includes replacing spring or metal weave isolation with elastomeric isolators. Figure A4 illustrates isolation recommendations for the RTAC. For chiller sound ratings, installation tips and considerations on chiller location, pipe isolation, etc., refer to theTrane Air-Cooled Series R Chillers Sound Data and Application Guide for Noise Sensitive Installations. System Options - Ice Storage Trane air-cooled Series R Chillers are well suited for ice production. An air-cooled machine typically switches to ice production at night.Two things happen under this assumption. First, the leaving brine temperature from the evaporator is lowered to around 22 to 24°F (-5.5 to -4.4°C). Second, the ambient temperature has typically dropped about 15 to 20°F (8.3 to 11°C) from the peak daytime ambient.This effectively places a lift on the compressors that is similar to daytime running conditions.The chiller can operate in lower ambient at night and successfully produce ice to supplement the next day's cooling demands. The Model RTAC produces ice by supplying ice storage tanks with a constant supply of glycol solution. Air-cooled chillers selected for these lower leaving fluid temperatures are also selected for efficient production of chilled fluid at nominal comfort cooling conditions.The ability ofTrane chillers to serve “double duty” in ice production and comfort cooling greatly reduces the capital cost of ice storage systems. When cooling is required, ice chilled glycol is pumped from the ice storage tanks directly to the cooling coils. No expensive heat exchanger is required.The glycol loop is a sealed system, eliminating expensive annual chemical treatment costs.The air-cooled chiller is also available for comfort cooling duty at nominal cooling conditions and efficiencies.The modular concept of glycol ice storage systems and the proven simplicity ofTraneTracer controllers allow the successful blend of reliability and energy saving performance in any ice storage application. The ice storage system is operated in six different modes: each optimized for the utility cost of the hour. 1. Provide comfort cooling with chiller 2. Provide comfort cooling with ice 3. Provide comfort cooling with ice and chiller 4. Freeze ice storage 5. Freeze ice storage when comfort cooling is required 6. Off Tracer optimization software controls operation of the required equipment and accessories to easily transition from one mode of operation to another. For example: Even with ice storage systems there are numerous hours when ice is neither produced or consumed, but saved. In this mode the chiller is the sole source of cooling. For example, to cool the building after all ice is produced but before high electrical demand charges take effect,Tracer sets the air-cooled chiller leaving fluid setpoint to its most efficient setting and starts the chiller, chiller pump, and load pump. RLC-PRC006M-EN 11 Application Considerations When electrical demand is high, the ice pump is started and the chiller is either demand limited or shut down completely.Tracer controls have the intelligence to optimally balance the contribution of ice and chiller in meeting the cooling load. The capacity of the chiller plant is extended by operating the chiller and ice in tandem.Tracer rations the ice, augmenting chiller capacity while reducing cooling costs.When ice is produced,Tracer will lower the air-cooled chiller leaving fluid setpoint and start the chiller, ice and chiller pumps, and other accessories. Any incidental loads that persist while producing ice can be addressed by starting the load pump and drawing spent cooling fluid from the ice storage tanks. For specific information on ice storage applications, contact your localTrane sales office. 12 RLC-PRC006M-EN Model Number Descriptions Digits 1, 2 - Unit Model Digit 16 - Evaporator Configuration Digit 27 - Electrical Protection Options 0 5 6 Digit 4 - Development Sequence N P Q R C Digit 17 - Condenser Application RT = Rotary chiller Digit 3 - Unit Type A = = Air-cooled Development sequence Digits 5, 6 & 7 - Nominal Capacity 140 155 170 185 200 225 250 275 300 350 400 450 500 = = = = = = = = = = = = = 140 Nominal tons 155 Nominal tons 170 Nominal tons 185 Nominal tons 200 Nominal tons 225 Nominal tons 250 Nominal tons 275 Nominal tons 300 Nominal tons 350 Nominal tons 400 Nominal tons 450 Nominal tons 500 Nominal tons Digit 8 - Unit Voltage A C J 4 5 = = = = = 200/60/3 230/60/3 380/60/3 460/60/3 575/60/3 Digit 9 - Manufacturing Location U = Water Chiller Business Unit, Pueblo, CO USA Digits 10, 11 - Design Sequence XX = Factory Input Digit 12 - Unit Basic Configuration N H A = = = Standard efficiency/performance High efficiency/performance Extra efficiency/performance N H L W = = = = = = = = 2 pass, 0.75” insulation 3 pass, 0.75” insulation 2 pass, 1.25” insulation 3 pass, 1.25” insulation Standard ambient (25-115°F) High ambient (25-125°F) Low ambient (0-115°F) Wide ambient (0-125°F) = = = No short circuit rating Default short circuit rating High amp short circuit rating Digit 28 - Flow Switch T = U = Factory installed flow switch water Factory installed flow switch glycol Digit 18 - Condenser Fin Material Digit 29 - Control Panel Accessories 1 2 4 N A = = = Standard aluminum slit fins Copper fins CompleteCoat™ epoxy coated fins Digit 19 - Condenser Fan/Motor Configuration T = W = STD fans withTEAO motors Low noise fans Digit 20 - Compressor Motor Starter Type X Y = = Across-the-line Wye-delta closed transition Digit 21 - Incoming Power Line Connection 1 2 = Single point power connection = Dual point power connection Digit 22 - Power Line Connection Type T D C = = = Terminal block connection Non-fused disconnect switch(es) Circuit breaker(s) ) Digit 23 - Unit Operator Interface D = DynaView operator interface = = No convenience outlet 15A 115V convenience outlet (60Hz) Digit 30 - Service Valves 1 = With suction service valves Digit 31 - Compressor Sound Attenuation Option 0 = 1 = No compressor sound attenuation Factory installed compressor sound attenuation Digit 32 - Appearance Options N A C = = = No appearance options Architectural louvered panels Half louvers Digit 33 - Installation Accessories N F R G E = = = = = S = No installation accessories Flange kit for water connections Neoprene in shear unit isolators Neoprene isolators and flange kit Seismic elastomeric isolation pads Seismic spring isolators Digit 13 - Agency Listing Digit 24 - Remote Operator Interface Digit 34 - Factory Testing Options N U S R N C B L 0 C = = C = E = = = = = No agency listing C/UL listing Seismic rated - IBC and OSHPD C/UL listed and seismic rated Digit 14 - Pressure Vessel Code A C D L = = = = ASME pressure vessel code Canadian code Australian code Chinese code Digit 15 - Evaporator Application F G R = = = Standard (40-60 F) leaving temp Low (Less than 40 F) leaving temp Remote (40-60 F) leaving temp RLC-PRC006M-EN = = = = No remote interface Tracer™ Comm 3 interface BACnet® interface LonTalk® compatible (LCI-C) interface Digit 25 - Control Input Accessories/Options N R = = C B = = No remote inputs Ext. evaporator leaving water setpoint Ext. current limit setpoint Ext. leaving water and current limit setpoint Standard functional test Customer-witnessed performance test with report Customer-witnessed performance test plus Rapid Restart test Non-witnessed performance test with report Digit 35 — Control, Label & Literature C E F = = = Spanish English French Digit 36 — Special Order Digit 26 - Control Output Accessories/Options X S N A C D Digit 37 — Safety Devices = = = = No output options Alarm relay outputs Ice making I/O Alarm relay outputs and ice making I/O N = = = Standard unit configuration Unit has special order feature Standard 13 General Data Table 1. 60 Hz standard efficiency — I-P Size 140 155 170 185 200 225 250 275 Compressor Quantity Nominal size @60Hz # 2 2 2 2 2 2 2 (tons) 70/ 70 85/ 70 85/ 85 100/ 85 100/ 100 120/ 100 120/ 120 Evaporator Water storage 300 350 400 450 500 3 3 4 4 4 Screw 3 85-85/ 100-100/ 120-120/ 100-100/ 120-120/ 120-120/ 100 100 100 100-100 100-100 120-120 Flooded (gal) 29 32 34 36 40 39 43 62 67 72 83 86 91 Min flow (gpm) 193 214 202 217 241 217 241 309 339 375 404 422 461 Max flow (gpm) 709 785 741 796 883 796 883 1134 1243 1374 1483 1548 1690 4 4 6 6 6 6 6 8 8 8 8 8 8 2 pass arrangement Water connection (NPS-in) 3 pass arrangement Min flow (gpm) 129 143 135 145 161 145 161 206 226 250 270 282 307 Max flow (gpm) 473 523 494 531 589 531 589 756 829 916 989 1032 1127 3.5 3.5 4 4 4 4 4 6 6 6 8 8 8 Water connection (NPS-in) Condenser Fin and tube Qty of coils # 4 4 4 4 4 4 4 8 8 8 8 8 8 Coil length (in) 156/ 156 180/ 156 180/ 180 216/ 180 216/ 216 252/ 216 252/ 252 180/ 108 216/108 252/108 216/216 252/216 252/252 Coil height # of rows Fins per foot (in) 42 42 42 42 42 42 42 42 42 42 42 42 42 (mm) 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 # 3 3 3 3 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 192 192 192 192 14/6 12/12 14/12 14/14 Fan Direct drive propeller Quantity Diameter Air flow per fan Power/motor # 4/4 5/4 5/5 6/5 6/6 7/6 7/7 10/6 12/6 (in) 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 30.0 (cfm) 9625 9394 9209 9209 9209 9210 9210 9209 9209 9208 9209 9210 9214 (hp) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 (rpm) 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 Tip speed (Ft/min) 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 Fan speed General Unit HFC-134a # Refrig ckts # 2 2 2 2 2 2 2 2 2 2 2 2 2 % min load % 15 15 15 15 15 15 15 15 15 15 15 15 15 Refrigerant charge (lb) 165/ 165 175/ 165 175/ 175 215/ 210 215/ 215 225/ 215 225/ 225 365/ 200 415/200 460/200 415/415 460/415 460/460 Oil charge (gal) 1.3/ 1.3 1.3/ 1.3 1.3/ 1.3 1.9/ 1.3 1.9/ 1.9 1.9/ 1.9 1.9/ 1.9 4.2/1.9 4.6/2.9 4.6/1.9 4.6/4.6 4.6/4.6 4.6/4.6 Min ambient-std (°F) 25 25 25 25 25 25 25 25 25 25 25 25 25 Min ambient-low (°F) 0 0 0 0 0 0 0 0 0 0 0 0 0 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. 14 RLC-PRC006M-EN General Data Table 2. 60 Hz high efficiency — I-P Size 140 155 170 185 200 Compressor Quantity Nominal size @60Hz 225 250 275 300 350 400 Screw # 2 2 2 2 2 2 100/100 120/100 2 3 3 4 4 120/120 85-85/ 100 100100/100 85-85/ 85/85 100-100/ 100-100 72 72 83 91 (tons) 70/70 85/70 85/85 100/85 (gal) 34 36 40 39 43 43 43 Min flow (gpm) 202 217 241 217 241 241 241 375 375 404 461 Max flow (gpm) 741 796 883 796 883 883 883 1374 1374 1483 1690 6 6 6 6 6 6 6 8 8 8 8 Evaporator Water storage Flooded 2 pass arrangement Water connection (NPS-in) 3 pass arrangement Min flow (gpm) 135 145 161 145 161 161 161 250 250 270 307 Max flow (gpm) 494 531 589 531 589 589 589 916 916 989 1127 4 4 4 4 4 4 4 6 6 8 8 8 8 Water connection (NPS-in) Condenser Fin and tube Qty of coils # Coil length (in) Coil height (in) Number of rows Fins per foot 4 4 4 4 4 8 180/180 216/180 216/216 252/216 252/252 144/144 42 42 42 42 42 42 8 8 144/144 216/144 42 42 252/144 216/216 42 42 8 252/252 42 # 3 3 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 192 192 # 5/5 6/5 6/6 7/6 7/7 12/6 14/6 12/12 14/14 Fan Direct drive propeller Quantity Diameter Air flow/fan Power/motor Fan speed 8/6 8/8 (in) 30 30 30 30 30 30 30 30 30 30 30 (cfm) 9199 9199 9199 9200 9201 9783 9203 9652 9605 9199 9201 (hp) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 (rpm) 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 1140 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 8954 Tip speed (Ft/Min) General Unit HFC-134a # Refrig ckts # 2 2 2 2 2 2 2 2 2 2 2 % min load % 15 15 15 15 15 15 15 15 15 15 15 Refrigerant charge (lb) 175/175 215/205 215/215 225/215 225/225 235/235 235/235 415/200 460/200 415/415 460/460 Oil charge (gal) 1.3/1.3 1.3/1.3 1.3/1.3 1.9/1.3 1.9/1.9 1.9/1.9 1.9/1.9 2.1-2.1/ 1.9 2.3-2.3/ 1.9 2.1-2.1/ 2.1-2.1 2.3-2.3/ 2.3-2.3 Min ambient-std (°F) 25 25 25 25 25 25 25 25 25 25 25 Min ambient-low (°F) 0 0 0 0 0 0 0 0 0 0 0 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. RLC-PRC006M-EN 15 General Data Table 3. 60 Hz extra efficiency — I-P Size 140 155 170 185 200 Compressor Quantity Nominal size @60Hz # (tons) 2 70/70 2 85/70 2 85/85 2 275 3 3 4 4 70-70/85 85-85/85 70-70/ 70-70 85-85/ 85-85 72 72 83 91 2 100/85 Evaporator Water storage 250 300 350 Screw 100/100 Flooded (gal) 40 39 43 43 43 Min flow (gpm) 241 217 241 241 241 375 375 404 461 Max flow (gpm) 883 796 883 883 883 1374 1374 1483 1690 6 6 6 6 6 8 8 8 8 2 pass arrangement Water connection (NPS-in) 3 pass arrangement Min flow (gpm) 161 145 161 161 161 250 250 270 307 Max flow (gpm) 589 531 589 589 589 916 916 989 1127 4 4 4 4 4 6 6 8 8 Water connection (NPS-in) Condenser Fin and tube Qty of coils # 4 4 4 8 8 8 8 8 8 Coil length (in) 216/216 252/216 252/252 144/144 144/144 216/144 252/144 216/216 252/252 Coil height (in) 42 42 42 42 42 42 42 42 42 # 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 Quantity # 6/6 7/6 7/7 8/6 8/8 12/6 14/6 12/12 14/14 Diameter (in) 30 30 30 30 30 30 30 30 30 (cfm) 9199 9200 9201 9783 9203 9652 9605 9199 9201 Number of rows Fins per foot Fan Direct drive propeller Air flow/fan Power/motor Fan speed (hp) 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 1.5 (rpm) 1140 1140 1140 1140 1140 1140 1140 1140 1140 8954 8954 8954 8954 8954 8954 8954 8954 8954 Tip speed (Ft/Min) General Unit HFC-134a # Refrig ckts # 2 2 2 2 2 2 2 2 2 % min load % 15 15 15 15 15 15 15 15 15 Refrigerant charge (lb) 215/215 225/215 225/225 235/235 235/235 415/200 460/200 415/415 460/460 Oil charge (gal) 1.3/1.3 1.9/1.3 1.9/1.9 1.9/1.9 1.9/1.9 2.1-2.1/ 2.1-2.1 2.1-2.1/ 2.1-2.1 Min ambient-std (°F) 25 25 25 25 25 25 25 25 25 Min ambient-low (°F) 0 0 0 0 0 0 0 0 0 2.1-2.1/1.9 2.1-2.1/1.9 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. 16 RLC-PRC006M-EN General Data Table 4. 60 Hz standard efficiency — SI Size 140 155 170 185 200 225 250 275 Compressor Quantity 300 350 400 450 500 3 3 4 4 4 Screw # Nominal size (tons) @60Hz 2 2 2 2 2 2 2 100/ 100 120/ 100 120/ 120 3 70/70 85/70 85/85 100/ 85 85-85/ 100-100/ 120-120/ 100-100/ 120-120/ 120-120/ 100 100 100 100-100 100-100 120-120 (L) 110.0 121 129 136 151 148 163 235 254 273 314 326 Min flow (L/s) 12 14 13 14 15 14 15 19 21 24 25 27 29 Max flow (L/s) 45 50 47 50 56 50 56 72 78 87 94 98 107 4 4 6 6 6 6 6 8 8 8 8 8 8 Evaporator Water storage Flooded 344 2 pass arrangement Water connection (NPS-in) 3 pass arrangement Min flow (L/s) 8 9 9 9 10 9 10 13 14 16 17 18 19 Max flow (L/s) 30 33 31 34 37 34 37 48 52 58 62 65 71 3.5 3.5 4 4 4 4 4 6 6 6 8 8 8 Water connection (NPS-in) Condenser Qty of coils Fin and tube # 4 4 4 8 8 8 8 8 8 Coil length (mm) 3962/ 3962 4572/ 3962 4572/ 5486/ 5486/ 6400/ 4572 4572 5486 5486 6400/ 6400 4572/ 2743 5486/ 2743 6400/ 2743 5486/ 5486 6400/ 5486 6400/ 6400 Coil height (mm) 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 # of rows Fins per foot 4 4 1067 4 1067 4 1067 # 3 3 3 3 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 192 192 192 192 14/14 Fan Direct drive propeller Quantity # 4/4 5/4 5/5 6/5 6/6 7/6 7/7 10/6 12/6 14/6 12/12 14/12 Diameter (mm) 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 726.0 Air flow per fan (m³/hr) 16351 15958 15644 15644 15644 15646 15647 15644 15645 15642 15645 15646 15653 1.12 1.12 1.12 1.12 1.12 1.12 Power/motor (kW) 1.12 1.12 1.12 1.12 1.12 1.12 1.12 Fan speed (rps) 19 19 19 19 19 19 19 19 19 19 19 19 19 Tip speed M/S 45 45 45 45 45 45 45 45 45 45 45 45 45 # Refrig ckts # 2 2 2 2 2 2 2 2 2 2 2 2 2 % min load % 15 15 15 15 15 General Unit HFC-134a Refrigerant charge (kg) 75/75 Oil charge (L) 5/5 79/75 79/79 5/5 5/5 98/95 98/98 7/5 7/7 15 15 15 15 15 15 15 15 102/ 98 102/ 102 166/91 188/91 209/91 188/188 209/188 209/209 7/7 7/7 8-8/7 9-9/11 9-9/11 9-9/9-9 9-9/9-9 9-9/9-9 Min ambient-std (°C) -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 Min ambient-low (°C) -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. RLC-PRC006M-EN 17 General Data Table 5. 60 Hz high efficiency — SI Size 140 Compressor Quantity Nominal size @60Hz 155 170 185 200 225 250 2 2 2 2 2 2 275 300 350 400 Screw # 2 100/100 120/100 120/120 3 3 4 4 85-85/ 100 100100/100 85-85/ 85/85 100-100/ 100-100 344 (tons) 70/70 85/70 85/85 100/85 (L) 129 136 151 148 163 163 163 273 273 314 Min flow (L/s) 13 14 15 14 15 15 15 24 24 25 29 Max flow (L/s) 47 50 56 50 56 56 56 87 87 94 107 6 6 6 6 6 6 6 8 8 8 8 Evaporator Water storage Flooded 2 Pass arrangement Water connection (NPS-in) 3 Pass arrangement Min flow (L/s) 9 9 10 9 10 10 10 16 16 17 19 Max flow (L/s) 31 34 37 34 37 37 37 58 58 62 71 4 4 4 4 4 4 4 6 6 8 8 Water connection (NPS-in) Condenser Qty of coils Fin and tube # 4 4 4 4 4 8 8 8 8 8 8 Coil length (mm) 4572/ 4572 5486/ 4572 5486/ 5486 6400/ 5486 6400/ 6400 3657/ 3657 3657/ 3657 5486/ 3657 6400/ 3657 5486/ 5486 6400/ 6400 Coil height (mm) 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 1067 Number of rows Fins per foot # 3 3 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 192 192 14/14 Fan Direct drive propeller Quantity # 5/5 6/5 6/6 7/6 7/7 8/6 8/8 12/6 14/6 12/12 Diameter (mm) 762 762 762 762 762 762 762 762 762 762 762 15628 15628 15628 15629 15631 16619 15634 16397 16317 15628 15631 1.12 1.12 1.12 1.12 1.12 1.12 1.12 1.12 1.12 1.12 1.12 Air per fan (m³/hr) Power/motor (kW) Fan speed (rps) 19 19 19 19 19 19 19 19 19 19 19 Tip speed M/S 45 45 45 45 45 45 45 45 45 45 45 # 2 2 2 2 2 2 2 2 2 2 2 15 15 15 General Unit # refrig ckts % min load Refrig charge Oil charge HFC-134a % 15 15 15 15 (kg) 79/79 98/93 98/98 102/98 102/102 107/107 107/107 15 15 15 15 188/91 209/91 188/188 209/209 (L) 5/5 5/5 5/5 7/5 7/7 7/7 7/7 8-8/7 9-9/7 8-8/8-8 9-9/9-9 Min ambient-std (°C) -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 Min ambient-low (°C) -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. 18 RLC-PRC006M-EN General Data Table 6. 60 Hz extra efficiency — SI Size 140 155 170 185 200 250 275 300 350 2 2 2 2 2 3 3 4 4 85-85/100 100-100/ 100 85-85/85/ 85 100-100/ 100-100 344 Compressor Quantity Nominal size @60Hz # (tons) 85/85 100/85 100/100 120/100 Evaporator Water storage 120/120 Flooded (L) 151 148 163 163 163 273 273 314 Min flow (L/s) 15 14 15 15 15 24 24 25 29 Max flow (L/s) 56 50 56 56 56 87 87 94 107 6 6 6 6 6 8 8 8 8 2 Pass arrangement Water connection (NPS-in) 3 Pass arrangement Min flow (L/s) 10 9 10 10 10 16 16 17 19 Max flow (L/s) 37 34 37 37 37 58 58 62 71 4 4 4 4 4 6 6 8 8 8 8 8 8 Water connection (NPS-in) Condenser Fin and tube Qty of coils # Coil length (mm) Coil height (mm) 1067 1067 1067 1067 1067 1067 1067 1067 # 3 3 3 3 3 3 3 3 3 (fpf) 192 192 192 192 192 192 192 192 192 Quantity # 6/6 7/6 7/7 8/6 8/8 12/6 14/6 12/12 14/14 Diameter (mm) 762 762 762 762 762 762 762 762 762 15628 15629 15631 16619 15634 16397 16317 15628 15631 1.12 Number of rows Fins per foot 4 4 4 8 8 5486/5486 6400/5486 6400/6400 3657/3657 4572/2743 5486/3657 6400/3657 5486/5486 Fan 6400/6400 1067 Direct drive propeller Air per fan (m³/hr) Power/motor (kW) 1.12 1.12 1.12 1.12 1.12 1.12 1.12 1.12 Fan speed (rps) 19 19 19 19 19 19 19 19 19 Tip speed M/S 45 45 45 45 45 45 45 45 45 General Unit HFC-134a # refrig ckts # 2 2 2 2 2 2 2 2 2 % min load % 15 15 15 15 15 15 15 15 15 (kg) 98/98 102/98 102/102 107/107 107/107 188/91 209/91 188/188 209/209 8-8/8-8 Refrig charge (L) 5/5 7/5 7/7 7/7 7/7 8-8/7 8-8/7 8-8/8-8 Min ambient-std Oil charge (°C) -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 -3.9 Min ambient-low (°C) -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 -17.8 1. Data containing information on two circuits is shown as follows: ckt 1/ ckt 2. 2. Minimum start-up/operating ambient is based on a 5 mph wind across the condenser. RLC-PRC006M-EN 19 Performance Data Table 7. 60 Hz standard efficiency – I-P units Evap Leaving Water Temp (°F) 40 42 44 20 Cond Entering Air Temp (°F) 85 95 105 115 Unit Size Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ 140 138.1 139.6 10.9 128.3 151.9 9.4 118.3 165.8 8 108 181.2 6.7 155 151.5 151.6 11 141 165 9.5 130.1 180.1 8.1 119 196.9 6.8 170 165.6 163.8 11.1 154.4 178.5 9.6 142.7 194.9 8.2 130.9 213.2 6.9 185 181.5 182 10.9 169.2 197.8 9.5 156.6 215.5 8.1 143.6 235.4 6.8 200 198.5 201 10.9 185.1 217.8 9.4 171.3 236.9 8.1 156.9 258.3 6.8 225 218 221.6 10.8 203.6 240.2 9.4 188.6 261.2 8.1 173.1 284.8 6.8 250 239.1 243.3 10.8 223.5 263.6 9.4 207.2 286.6 8.1 190.2 312.4 6.9 275 265.5 266.3 10.9 247.6 289.2 9.5 229.1 315.1 8.1 210.2 344 6.9 300 298.4 304.8 10.8 278.3 329.8 9.4 257.6 358.3 8 236.3 390.2 6.8 350 338.9 348.7 10.7 316.6 377.1 9.3 293.4 409.3 8 269.3 445.4 6.8 400 400.7 409.7 10.8 374.1 443.2 9.4 346.4 481.3 8 317.9 524 6.8 450 440.8 453.5 10.7 412 490.4 9.3 382 532.4 8 350.9 579.4 6.8 500 482.4 498.3 10.7 451.1 538.5 9.3 418.5 584.2 8 384.5 635.4 6.8 140 143.4 142.6 11.1 133.3 155 9.6 122.9 168.9 8.1 112.2 184.4 6.9 155 157.3 154.8 11.2 146.4 168.3 9.6 135.2 183.5 8.2 123.7 200.4 6.9 170 171.8 167.3 11.3 160.2 182 9.7 148.3 198.6 8.3 136 217 7 185 188.2 185.9 11.1 175.6 201.8 9.6 162.5 219.7 8.3 149.1 239.6 7 200 205.8 205.4 11 192 222.4 9.6 177.7 241.6 8.2 162.9 263.1 7 225 225.9 226.5 11 211.1 245.3 9.6 195.6 266.5 8.2 179.6 290.3 7 250 247.9 248.8 11 231.7 269.3 9.6 214.8 292.6 8.2 197.3 318.6 7 275 275.3 272 11.1 256.8 295.1 9.6 237.8 321.1 8.3 218.3 350.2 7 300 309.3 311.6 10.9 288.6 336.8 9.5 267.2 365.4 8.2 245.2 397.5 6.9 350 351.3 356.7 10.9 328.2 385.3 9.5 304.2 417.8 8.2 279.3 454.3 6.9 400 415.1 418.8 10.9 387.6 452.6 9.5 359.1 490.9 8.2 329.7 533.8 7 450 456.6 463.7 10.9 426.8 500.9 9.5 395.8 543.2 8.2 363.7 590.7 6.9 500 499.7 509.7 10.9 467.4 550.3 9.5 433.6 596.4 8.2 398.5 648.3 6.9 140 148.7 145.6 11.3 138.3 158.1 9.7 127.6 172.1 8.3 116.6 187.7 7 155 163.1 158.1 11.4 151.9 171.7 9.8 140.3 187 8.4 128.5 204 7.1 170 178.1 170.8 11.5 166.1 185.6 9.9 153.8 202.3 8.5 141.3 220.8 7.2 185 195 189.9 11.3 182 205.9 9.8 168.5 223.9 8.4 154.7 244 7.1 200 213.2 210 11.2 198.9 227.1 9.7 184.2 246.4 8.4 169 268.1 7.1 225 234 231.6 11.2 218.6 250.5 9.7 202.7 271.9 8.4 186.1 295.9 7.1 250 256.8 254.5 11.2 240.1 275.2 9.7 222.6 298.7 8.4 204.4 325 7.1 275 285.3 277.9 11.3 266.2 301.1 9.8 246.6 327.3 8.4 226.5 356.5 7.2 300 320.3 318.6 11.1 299 343.9 9.7 276.9 372.7 8.3 254.2 405 7.1 350 363.9 364.9 11 340 393.7 9.6 315.2 426.5 8.3 289.5 463.3 7.1 400 429.7 428.1 11.1 401.3 462.1 9.7 371.9 500.6 8.3 341.6 543.7 7.1 450 472.6 474.1 11 441.9 511.7 9.6 409.9 554.3 8.3 376.7 602.2 7.1 500 517.3 521.4 11 483.9 562.4 9.6 449 609 8.3 412.6 661.4 7.1 RLC-PRC006M-EN Performance Data Table 7. 60 Hz standard efficiency – I-P units (continued) Evap Leaving Water Temp (°F) 46 48 Cond Entering Air Temp (°F) 85 95 105 EER³ Tons kW Input² EER³ Tons kW Input² 115 EER³ Tons kW Input² EER³ Unit Size Tons kW Input² 140 154.1 148.8 11.5 143.4 161.3 9.9 132.3 175.4 8.5 121 191 7.2 155 169 161.5 11.6 157.4 175.2 10 145.6 190.5 8.6 133.4 207.6 7.2 170 184.5 174.4 11.7 172.2 189.3 10.1 159.5 206.1 8.7 146.6 224.7 7.3 185 201.9 194.1 11.5 188.5 210.1 10 174.6 228.3 8.6 160.4 248.5 7.3 200 220.7 214.7 11.4 206 231.9 9.9 190.8 251.3 8.5 175.1 273.1 7.2 225 242.1 236.8 11.3 226.3 255.8 9.9 209.8 277.5 8.5 192.8 301.7 7.2 250 265.8 260.2 11.3 248.5 281.2 9.9 230.5 304.9 8.5 211.6 331.6 7.2 275 295.4 284 11.5 275.8 307.3 10 255.6 333.6 8.6 234.9 362.9 7.3 300 331.5 325.7 11.3 309.5 351.2 9.8 286.7 380.2 8.5 263.3 412.6 7.2 350 376.6 373.3 11.2 352 402.4 9.8 326.3 435.4 8.4 297.3 467.6 7.2 400 444.4 437.6 11.2 415.2 471.8 9.8 384.9 510.5 8.5 353.7 553.8 7.2 450 488.8 484.8 11.2 457.1 522.7 9.8 424.1 565.7 8.4 384.5 602.6 7.2 500 535.2 533.4 11.2 500.7 574.8 9.7 464.5 621.9 8.4 416.8 652.5 7.2 140 159.6 152 11.7 148.5 164.6 10.1 137.1 178.7 8.6 124.5 192.8 7.3 155 175 164.9 11.7 163.1 178.7 10.2 150.8 194.2 8.7 137.3 209.6 7.4 170 190.9 178.1 11.8 178.3 193.1 10.3 165.3 210 8.8 152 228.6 7.5 185 208.9 198.3 11.6 195.1 214.5 10.1 180.8 232.7 8.7 166.2 253 7.4 200 228.2 219.4 11.5 213.1 236.7 10 197.4 256.3 8.6 181.3 278.1 7.4 225 250.4 242 11.5 234.1 261.3 10 217.1 283.1 8.6 199.5 307.5 7.3 250 275 266.2 11.5 257.1 287.3 10 238.4 311.3 8.6 216 331.7 7.4 275 305.7 290.2 11.7 285.4 313.6 10.1 264.7 340 8.7 243.3 369.5 7.4 300 342.8 333 11.4 320.1 358.7 10 296.7 387.7 8.6 272.5 420.3 7.3 350 389.6 381.8 11.3 364.1 411.2 9.9 337.5 444.5 8.5 301.2 462.7 7.3 400 459.4 447.4 11.4 429.2 481.7 9.9 398.1 520.6 8.6 363.2 558.7 7.3 450 505.3 495.8 11.3 472.6 533.9 9.9 438.5 577.3 8.5 389.9 597.2 7.4 500 553.4 545.7 11.3 517.7 587.5 9.9 480.3 635.2 8.5 421.5 644.1 7.4 1. Rated in accordance with AHRI Standard 550/590 based on TOPSS version 140: sea level altitude, evaporator fouling factor of 0.0001°F-ft²h/Btu, evaporator temperature drop of 10°F, and 2 pass evaporator configuration. Consult a Trane representative for additional performance information. 2. kW input is for compressors only. 3. EER = Energy Efficiency Ratio (Btu/watt-hour). Power inputs include compressors, condenser fans and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. RLC-PRC006M-EN 21 Performance Data Table 8. 60 Hz high efficiency – I-P units Evap Leaving Water Temp (°F) 40 42 44 22 Cond Entering Air Temp (°F) 85 95 105 115 Unit Size Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ 140 141.1 134.3 11.3 131.4 145.8 9.8 121.4 158.8 8.4 111.1 173.5 7.1 155 156.2 145.2 11.5 145.6 157.9 10 134.7 172.3 8.6 123.5 188.4 7.2 170 170.1 156.6 11.7 158.7 170.4 10.1 147 186.1 8.6 134.9 203.6 7.3 185 186.9 175.1 11.5 174.6 190 10 161.8 206.9 8.6 148.7 225.9 7.3 200 204.8 194.4 11.4 191.4 210.2 9.9 177.4 228.3 8.5 163.1 248.7 7.3 225 221.3 215.8 11.2 207.2 233.2 9.8 192.5 253.1 8.4 177.2 275.5 7.2 250 244.1 236.8 11.2 228.8 255.9 9.8 212.8 277.7 8.5 196.1 302.3 7.2 275 273.5 256.1 11.6 255.4 277.6 10.1 236.8 302.2 8.6 217.7 329.8 7.3 300 306.7 294.5 11.3 286.8 318 9.9 266.1 344.9 8.5 244.8 375.2 7.3 350 344.2 318.4 11.6 321.6 346 10.1 298.2 377.3 8.7 274.3 412.4 7.3 400 413 396.6 11.3 386.3 428 9.9 358.5 463.9 8.5 329.9 504.4 7.3 140 146.6 137 11.5 136.7 148.6 10 126.3 161.8 8.6 115.7 176.5 7.3 155 162.3 148.2 11.8 151.4 161 10.2 140.2 175.4 8.8 128.6 191.6 7.4 170 176.7 159.8 11.9 165 173.7 10.3 152.9 189.5 8.8 140.5 207.1 7.5 185 194 178.8 11.7 181.3 193.8 10.2 168.2 210.8 8.8 154.7 229.9 7.5 200 212.6 198.7 11.6 198.7 214.6 10.1 184.3 232.8 8.7 169.5 253.2 7.4 225 229.7 220.6 11.4 215.1 238.1 10 199.9 258.1 8.6 184.1 280.7 7.3 250 253.3 242.1 11.4 237.5 261.3 10 220.9 283.3 8.6 203.6 308.2 7.4 275 284 261.5 11.8 265.4 283.2 10.3 246.2 307.9 8.8 226.5 335.6 7.5 300 318.4 301 11.5 297.8 324.6 10.1 276.4 351.6 8.7 254.4 382.1 7.4 350 357.3 324.9 11.8 333.9 352.7 10.3 309.9 384.1 8.9 285.2 419.4 7.5 400 428.4 405.3 11.5 400.8 436.8 10 372.2 472.9 8.7 342.7 513.6 7.4 140 152.3 139.9 11.8 142 151.5 10.2 131.4 164.8 8.8 120.4 179.5 7.4 155 168.5 151.3 12 157.3 164.1 10.4 145.7 178.6 9 133.8 194.9 7.6 170 183.4 163.1 12.1 171.3 177.1 10.5 158.9 192.9 9 146.1 210.6 7.7 185 201.3 182.6 11.9 188.2 197.6 10.4 174.6 214.7 9 160.7 233.9 7.6 200 220.5 203.1 11.8 206.2 219 10.3 191.3 237.3 8.9 176 257.9 7.6 225 238.2 225.6 11.6 223.2 243.2 10.1 207.5 263.3 8.8 191.2 286.1 7.5 250 262.7 247.5 11.6 246.3 266.9 10.2 229.2 289.1 8.8 211.3 314.2 7.5 275 294.7 267.1 12 275.5 288.9 10.5 255.7 313.7 9 235.4 341.5 7.7 300 330.2 307.7 11.7 308.9 331.4 10.3 286.8 358.5 8.9 264.1 389.1 7.6 350 370.5 331.6 12.1 346.5 359.5 10.5 321.8 391.1 9 296.4 426.5 7.7 400 444.1 414.3 11.7 415.6 445.9 10.2 386.1 482.2 8.8 355.6 523 7.6 RLC-PRC006M-EN Performance Data Table 8. 60 Hz high efficiency – I-P units (continued) Evap Leaving Water Temp (°F) 46 48 Cond Entering Air Temp (°F) 85 95 105 EER³ Tons kW Input² EER³ Tons kW Input² 115 EER³ Tons kW Input² EER³ 7.6 Unit Size Tons kW Input² 140 158 142.8 12 147.4 154.5 10.4 136.5 167.8 9 125.2 182.7 155 174.8 154.4 12.2 163.2 167.3 10.6 151.3 181.9 9.2 139.1 198.2 7.8 170 190.3 166.4 12.3 177.8 180.5 10.7 165 196.4 9.2 151.9 214.2 7.9 185 208.6 186.5 12.1 195.1 201.6 10.6 181.2 218.7 9.1 166.9 238 7.8 200 228.5 207.5 12 213.7 223.6 10.5 198.4 241.9 9.1 182.7 262.6 7.7 225 246.9 230.6 11.8 231.3 248.3 10.3 215.1 268.6 8.9 198.3 291.5 7.6 250 272.2 253.1 11.8 255.3 272.6 10.3 237.6 295 8.9 219.1 320.4 7.7 275 305.6 272.9 12.2 285.8 294.7 10.7 265.4 319.6 9.2 244.4 347.5 7.8 300 342.1 314.5 11.9 320.2 338.3 10.4 297.5 365.6 9 274 396.3 7.7 350 384 338.5 12.3 359.3 366.5 10.7 333.9 398.2 9.2 307.8 433.7 7.9 400 459.9 423.4 11.8 430.6 455.2 10.4 400.2 491.6 9 368.8 532.6 7.7 140 163.9 145.8 12.2 153 157.6 10.6 141.7 170.9 9.1 129 184.2 7.8 155 181.2 157.6 12.5 169.3 170.6 10.8 157.1 185.2 9.3 143.7 200.4 8 170 197.2 169.9 12.6 184.4 184 10.9 171.2 200 9.4 157.7 217.9 8 185 216.1 190.5 12.3 202.2 205.6 10.8 187.9 222.8 9.3 173.1 242.2 8 200 236.6 212.1 12.2 221.4 228.2 10.7 205.7 246.6 9.2 189.4 267.3 7.9 225 255.7 235.8 11.9 239.6 253.6 10.5 222.9 274 9.1 205.5 297.1 7.8 250 281.9 258.7 12 264.5 278.4 10.5 246.1 301.1 9.1 226 324.8 7.8 275 316.7 278.7 12.4 296.2 300.7 10.8 275.2 325.6 9.4 253.7 353.6 8 300 354.3 321.5 12.1 331.6 345.4 10.6 308.2 372.7 9.2 284.1 403.6 7.9 350 397.8 345.5 12.5 372.3 373.6 10.9 346.2 405.5 9.4 319.4 441 8 400 476 432.8 12 445.8 464.7 10.6 414.5 501.2 9.2 382.1 542.4 7.9 1. Rated in accordance with AHRI Standard 550/590 based on TOPSS version 140: sea level altitude, evaporator fouling factor of 0.0001°F-ft²h/Btu, evaporator temperature drop of 10°F, and 2 pass evaporator configuration. Consult a Trane representative for additional performance information. 2. kW input is for compressors only. 3. EER = Energy Efficiency Ratio (Btu/watt-hour). Power inputs include compressors, condenser fans and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. RLC-PRC006M-EN 23 Performance Data Table 9. 60 Hz extra efficiency – I-P units Evap Leaving Water Temp (°F) 40 42 44 46 24 Cond Entering Air Temp (°F) 85 95 105 EER³ Tons kW Input² EER³ Tons kW Input² 115 EER³ Tons kW Input² Unit Size Tons kW Input² 140 146 129.3 11.8 136.1 140.2 10.3 125.8 152.6 8.8 114.9 166.6 7.5 155 160.8 140.3 12 150.1 152.4 10.5 139.1 166.2 9 127.4 181.7 7.6 170 176.3 151.7 12.2 164.7 164.9 10.6 152.8 180 9.1 140.1 196.8 7.7 185 189.4 170.9 11.8 177.2 184.9 10.3 164.6 201 8.9 150.9 219 7.6 200 207.9 190 11.6 194.6 205 10.2 180.9 222.2 8.8 165.7 241.5 7.5 250 234.9 206.6 12 219.3 224 10.5 203.1 243.9 9 185.7 266.2 7.6 275 264 229.4 12.2 246.8 249.1 10.6 229.2 271.6 9.1 210.1 296.6 7.7 300 295.9 262.3 11.8 276.2 284.1 10.3 255.8 309.1 8.9 233.5 337 7.5 350 355.9 308.8 12.1 332.9 335 10.6 309.1 365 9.1 283.2 398.4 7.7 140 151.9 131.9 12.1 141.7 142.9 10.5 131.1 155.4 9.1 119.9 169.4 7.7 155 167.2 143.1 12.3 156.2 155.3 10.7 144.8 169.2 9.2 132.8 184.7 7.8 170 183.3 154.7 12.5 171.4 168 10.9 159.1 183.2 9.3 146 200.1 7.9 185 196.8 174.5 12.1 184.3 188.6 10.5 171.2 204.8 9.1 157.2 222.8 7.8 200 216 194.1 11.8 202.3 209.1 10.4 188.1 226.4 9 172.4 245.8 7.7 250 244.3 210.8 12.3 228.2 228.3 10.7 211.6 248.3 9.2 193.6 270.7 7.8 275 274.4 234.1 12.4 256.7 253.8 10.8 238.5 276.4 9.3 218.9 301.5 7.9 300 307.6 267.6 12.1 287.3 289.6 10.6 266.3 314.6 9.1 243.4 342.6 7.7 350 369.8 315 12.4 346 341.4 10.8 321.6 371.4 9.3 295 405 7.9 140 158 134.6 12.4 147.5 145.6 10.8 136.6 158.2 9.3 125 172.3 7.9 155 173.7 146 12.5 162.4 158.2 10.9 150.7 172.2 9.4 138.3 187.7 8 170 190.4 157.9 12.7 178.1 171.2 11.1 165.5 186.4 9.6 152 203.4 8.1 185 204.4 178.2 12.3 191.5 192.3 10.8 178 208.6 9.3 163.5 226.7 7.9 200 224.2 198.4 12.1 210.1 213.4 10.6 195.5 230.8 9.2 179.3 250.2 7.9 250 253.9 215.1 12.5 237.3 232.7 11 220.2 252.8 9.4 201.7 275.2 8 275 285 238.8 12.7 266.8 258.6 11.1 248.1 281.3 9.6 227.9 306.5 8.1 300 319.6 273.1 12.4 298.7 295.1 10.8 277 320.3 9.3 253.4 348.4 7.9 350 383.9 321.4 12.6 359.5 347.9 11 334.3 378 9.6 307 411.6 8.1 140 164.2 137.3 12.6 153.3 148.4 11 142.1 161 9.5 130.2 175.2 8.1 155 180.4 149 12.8 168.7 161.2 11.2 156.7 175.2 9.7 143.9 190.8 8.2 170 197.7 161.1 13 185 174.4 11.3 172 189.7 9.8 158.2 206.7 8.3 185 212.2 182 12.5 198.8 196.2 11 185 212.4 9.5 170 230.6 8.1 200 232.5 202.7 12.3 218 217.8 10.8 202.9 235.2 9.4 186.3 254.7 8 250 263.7 219.6 12.8 246.6 237.2 11.2 229 257.3 9.7 209.9 279.8 8.2 275 295.9 243.7 12.9 277.1 263.6 11.3 257.8 286.2 9.8 237.1 311.5 8.3 300 331.8 278.7 12.6 310.3 300.8 11 288 326 9.5 263.6 354.2 8.1 350 398.3 328 12.9 373.2 354.5 11.3 347.3 384.7 9.8 319.1 418.4 8.3 EER³ RLC-PRC006M-EN Performance Data Table 9. 60 Hz extra efficiency – I-P units (continued) Evap Leaving Water Temp (°F) 48 Cond Entering Air Temp (°F) 85 95 105 115 Unit Size Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ Tons kW Input² EER³ 140 170.5 140.2 12.9 159.3 151.3 11.3 147.7 164 9.7 135.4 178.1 8.3 155 187.2 152 13.1 175.2 164.3 11.4 162.8 178.3 9.9 149.6 194 8.4 170 205.1 164.3 13.2 192.1 177.7 11.6 178.6 193 10 164.4 210.1 8.6 185 220 185.9 12.7 206.2 200.1 11.2 192 216.4 9.7 176.6 234.6 8.3 200 241 207.1 12.5 226.1 222.2 11 210.5 239.7 9.6 193.3 259.3 8.2 250 273.7 224.1 13 256.1 241.8 11.4 237.9 262 9.9 218.3 284.5 8.4 275 306.9 248.7 13.2 287.6 268.6 11.6 267.7 291.3 10 246.4 316.7 8.5 300 344.3 284.4 12.8 322.1 306.6 11.3 299.1 331.9 9.8 273.9 360.1 8.3 350 413 334.7 13.1 387.1 361.3 11.5 360.5 391.6 10 331.5 425.3 8.5 1. Rated in accordance with AHRI Standard 550/590 based on TOPSS version 140: sea level altitude, evaporator fouling factor of 0.0001°F-ft²h/Btu, evaporator temperature drop of 10°F, and 2 pass evaporator configuration. Consult a Trane representative for additional performance information. 2. kW input is for compressors only. 3. EER = Energy Efficiency Ratio (Btu/watt-hour). Power inputs include compressors, condenser fans and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. RLC-PRC006M-EN 25 Performance Data Table 10. AHRI and Part Load Performance — 60 Hz — I-P units Standard efficiency Unit Size Full Load Full Load Tons EER High efficiency IPLV Unit Size Full Load Full Load Tons EER Extra efficiency IPLV Unit Size Full Load Full Load Tons EER IPLV 140 138.3 9.7 13.6 140 142.0 10.2 13.8 140 147.5 10.8 14.3 155 151.9 9.8 14.0 155 157.3 10.4 14.5 155 162.4 10.9 14.9 170 166.1 9.9 14.0 170 171.3 10.5 14.5 170 178.1 11.1 14.9 185 182.0 9.8 13.9 185 188.2 10.4 14.3 185 191.4 10.8 14.8 200 198.9 9.7 13.6 200 206.1 10.3 14.1 200 210.1 10.6 14.1 225 218.6 9.7 13.9 225 223.2 10.1 14.1 250 237.3 11.0 14.8 250 240.1 9.7 13.7 250 246.3 10.2 14.0 275 266.8 11.1 15.2 275 266.2 9.8 14.6 275 275.5 10.5 14.8 300 298.7 10.8 14.8 300 298.9 9.7 14.2 300 308.9 10.3 14.4 350 359.5 11.0 15.3 350 340.0 9.6 14.3 350 346.5 10.5 15.4 400 401.3 9.7 14.7 400 415.6 10.2 14.7 450 441.8 9.6 15.0 500 483.9 9.6 15.0 1. IPLV values are rated in accordance with AHRI Standard 550/590 and based on TOPSS version 140. 2. EER and IPLV values include compressors, condenser fans, and control kW. 26 RLC-PRC006M-EN Performance Data Table 11. 60 Hz standard efficiency — SI units Evap Leaving Water Temp (°C) 5 7 9 Cond Entering Air Temp (°C) 30 Unit Size kW kW Cooling Input² 35 COP³ kW kW Cooling Input² 40 COP³ kW kW Cooling Input² 45 COP³ kW kW Cooling Input² COP³ 140 490.83 142.2 3.17 459.54 153.4 2.77 427.19 165.8 2.4 394.14 179.5 2.06 155 538.65 154.3 3.2 504.55 166.6 2.8 469.74 180.1 2.42 434.23 195.1 2.08 170 588.58 166.8 3.23 552.36 180.1 2.83 515.09 194.9 2.45 477.12 211.2 2.11 185 645.19 185.3 3.19 605.46 199.7 2.8 565.02 215.6 2.43 523.53 233.3 2.1 200 705.31 204.6 3.16 662.41 220 2.78 617.76 237.1 2.42 572.05 256.1 2.09 225 774.58 225.6 3.15 728.16 242.6 2.78 679.99 261.5 2.42 630.42 282.5 2.09 250 849.47 247.8 3.16 799.19 266.2 2.78 746.8 286.9 2.43 692.65 309.8 2.1 275 942.99 271.1 3.19 885.33 291.9 2.8 826.26 315.1 2.44 765.79 340.8 2.1 300 1059.72 310.2 3.13 995.03 333 2.76 928.93 358.6 2.41 860.72 386.9 2.08 350 1203.53 355 3.12 1131.8 380.8 2.75 1057.26 409.8 2.41 980.61 441.9 2.08 400 1423.28 417.1 3.13 1337.49 447.6 2.76 1248.88 481.7 2.41 1157.82 519.6 2.09 450 1565.32 461.6 3.12 1472.5 495.2 2.75 1376.51 532.9 2.41 1277.36 574.7 2.08 500 1713.35 507.4 3.11 1612.79 544 2.75 1508.01 585 2.41 1399.72 630.7 2.08 140 524.24 147.6 3.27 490.83 159 2.87 456.73 171.5 2.49 421.92 185.4 2.14 155 575.22 160.3 3.3 539.35 172.6 2.89 502.44 186.3 2.51 465.17 201.5 2.16 170 627.96 173.2 3.33 589.63 186.6 2.92 550.61 201.6 2.54 510.88 218 2.19 185 687.73 192.6 3.28 645.89 207.1 2.89 603.35 223.2 2.52 559.4 241.1 2.17 200 751.72 212.9 3.25 706.01 228.4 2.86 659.25 245.7 2.5 610.73 264.9 2.16 225 825.21 234.7 3.24 775.98 251.9 2.86 725 271.2 2.5 672.61 292.5 2.16 250 905.37 257.9 3.24 851.93 276.7 2.86 796.37 297.8 2.5 738.36 321.2 2.16 275 1005.58 281.7 3.28 944.75 302.7 2.89 882.52 326.2 2.52 818.53 352.1 2.18 300 1128.99 322.8 3.22 1060.43 345.8 2.84 990.46 371.6 2.48 918.38 400.2 2.15 350 1282.64 369.7 3.2 1205.99 395.9 2.83 1126.88 425.3 2.48 1045.31 457.9 2.15 400 1514.69 433.8 3.22 1423.98 464.7 2.84 1330.45 499.2 2.49 1234.12 537.4 2.15 450 1665.88 480.4 3.2 1567.43 514.5 2.83 1465.82 552.8 2.48 1360.34 595.2 2.15 500 1824.1 528.4 3.19 1717.22 565.7 2.83 1605.76 607.5 2.47 1490.43 654 2.14 140 558.34 153.4 3.37 523.18 164.8 2.96 487.32 177.5 2.57 450.4 191.4 2.21 155 612.49 166.5 3.4 574.87 178.9 2.98 536.19 192.8 2.6 496.46 208 2.24 170 668.39 179.8 3.42 628.31 193.4 3.01 587.17 208.5 2.63 544.98 225 2.27 185 731.33 200.1 3.37 687.38 214.8 2.97 642.37 231.1 2.59 596.31 249.1 2.25 200 798.84 221.4 3.33 750.67 237.1 2.94 701.09 254.6 2.57 650.46 273.9 2.23 225 876.89 244.2 3.32 825.21 261.7 2.93 771.06 281.2 2.57 715.51 302.8 2.22 250 962.68 268.5 3.32 906.07 287.7 2.93 846.65 309.2 2.57 785.47 333.1 2.22 275 1069.92 292.8 3.37 1005.58 314 2.97 939.83 337.6 2.6 872.67 363.7 2.25 300 1199.66 335.9 3.3 1127.58 359.1 2.92 1053.39 385.1 2.56 977.1 413.9 2.22 350 1363.51 385.1 3.28 1282.64 411.7 2.9 1198.6 441.5 2.54 1108.6 472.8 2.21 400 1608.22 451.3 3.3 1512.58 482.4 2.92 1413.78 517.2 2.56 1312.17 555.8 2.22 450 1768.9 500.1 3.28 1664.83 534.7 2.9 1557.24 573.4 2.54 1439.45 612.7 2.21 500 1937.67 550.5 3.27 1824.1 588.4 2.89 1705.61 631 2.54 1567.78 668.8 2.21 1. Ratings based on TOPSS version 140: evaporator fouling factor of 0.01761m²°C/kW, evaporator temperature drop of 5°C, and 2 pass evaporator configuration. Consult Trane representative for additional performance information. 2. kW input is for compressors only. 3. COP = Coefficient of Performance. Power inputs include compressors and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. RLC-PRC006M-EN 27 Performance Data Table 12. 60 Hz high efficiency — SI units Evap Leaving Water Temp (°C) 5 7 9 Cond Entering Air Temp (°C) 30 Unit Size kW kW Cooling Input² 140 501.73 155 170 35 COP³ kW kW Cooling Input² 40 COP³ 470.79 147.1 2.9 3.37 521.77 159.4 2.96 3.4 568.54 172 2.99 178.3 3.35 624.79 191.8 2.95 197.9 3.32 684.92 212.3 2.93 741.52 235.5 818.53 258.4 kW kW Cooling Input² 438.8 45 COP³ kW kW Cooling Input² 406.1 171.9 COP³ 136.7 3.29 158.9 2.52 2.17 555.88 147.8 605.1 159.4 486.97 172.3 2.58 451.1 186.6 2.22 530.92 186.1 2.6 492.59 201.7 2.24 185 664.52 200 727.81 584.01 206.9 2.58 542.17 223.8 2.23 640.26 228.5 2.57 594.2 246.5 2.22 225 786.88 219.7 3.27 250 867.75 241 3.27 2.89 694.41 253.3 2.53 645.54 273.3 2.2 2.9 767.19 278 2.54 713.75 299.9 2.21 275 972.53 260.6 3.37 914.51 280.2 2.97 854.74 302.2 2.6 793.91 326.8 2.25 300 1090.31 299.7 3.3 1025.97 321 2.92 959.87 345.1 2.56 891.66 372.1 2.22 350 1223.92 324.1 3.39 1151.14 349.1 2.98 1076.25 377.2 2.6 999.95 408.4 2.25 400 1467.93 403.6 3.29 1382.14 432.1 2.91 1293.19 464.3 2.55 1201.77 500.3 2.22 140 537.25 141.8 3.41 504.55 152.3 3.01 470.79 164.2 2.62 435.98 177.3 2.27 155 594.56 153.3 3.49 558.69 165 3.07 522.13 178 2.68 484.15 192.4 2.32 170 647.3 165.3 3.52 608.62 178 3.1 568.89 192.2 2.71 528.46 207.9 2.34 185 709.88 185.1 3.46 668.04 198.7 3.06 625.15 214 2.68 580.84 231 2.32 200 777.39 205.7 3.42 731.68 220.2 3.03 684.57 236.6 2.66 636.04 254.8 2.31 225 840.32 228.5 3.36 792.16 244.5 2.98 742.23 262.6 2.62 690.54 282.8 2.28 250 926.82 250.8 3.37 874.43 268.4 2.99 819.93 288.3 2.63 762.97 310.5 2.28 275 1039.68 270.7 3.48 978.15 290.4 3.08 915.22 312.6 2.7 850.52 337.3 2.34 300 1164.15 311.7 3.4 1096.29 333.2 3.02 1025.97 357.5 2.65 953.89 384.6 2.3 350 1306.9 336.1 3.5 1230.25 361.4 3.09 1151.49 389.7 2.7 1071.33 421.1 2.35 400 1566.03 419.7 3.38 1475.31 448.4 3.01 1381.44 480.8 2.64 1284.75 517.1 2.3 140 573.81 147.1 3.53 539 157.8 3.11 503.49 169.7 2.72 466.92 182.9 2.36 155 634.64 159 3.6 597.02 170.8 3.18 557.99 183.9 2.78 518.26 198.4 2.41 170 690.54 171.5 3.63 649.76 184.3 3.21 608.27 198.6 2.81 565.72 214.4 2.44 185 757 192.2 3.57 712.69 205.9 3.16 667.34 221.3 2.77 620.93 238.4 2.41 200 828.37 213.9 3.52 780.2 228.5 3.12 730.27 245 2.75 678.94 263.3 2.39 225 895.53 237.8 3.46 844.54 254 3.07 791.45 272.2 2.7 736.6 292.6 2.35 250 987.29 261 3.46 932.09 278.8 3.08 874.08 299.1 2.71 813.6 321.7 2.36 275 1108.6 281.2 3.59 1043.9 301.1 3.18 977.45 323.4 2.79 909.24 348.2 2.43 300 1240.45 324.2 3.5 1168.37 345.8 3.11 1094.18 370.3 2.74 1018.23 397.5 2.39 350 1393.04 348.6 3.61 1312.17 374.1 3.19 1229.55 402.6 2.8 1144.81 434.1 2.44 400 1666.94 436.4 3.48 1570.95 465.3 3.09 1471.8 498 2.73 1369.83 534.4 2.38 1. Ratings based on TOPSS version 140: evaporator fouling factor of 0.01761m²°C/kW, evaporator temperature drop of 5°C, and 2 pass evaporator configuration. Consult Trane representative for additional performance information. 2. kW input is for compressors only. 3. COP = Coefficient of Performance. Power inputs include compressors and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. 28 RLC-PRC006M-EN Performance Data Table 13. 60 Hz extra efficiency — SI units Evap Leaving Water Temp (°C) 5 7 9 Cond Entering Air Temp (°C) 30 35 40 45 Unit Size kW Cooling kW Input² COP³ kW Cooling kW Input² COP³ kW Cooling kW Input² COP³ kW Cooling kW Input² 140 519.66 131.5 3.46 488.02 141.5 3.05 455.32 152.7 2.66 421.57 165.1 2.3 155 572.05 142.8 3.51 537.95 153.8 3.1 502.44 166.2 2.7 466.22 180 2.34 170 627.25 154.4 3.56 589.98 166.4 3.14 552.01 179.9 2.75 512.63 194.9 2.38 185 674.02 173.9 3.45 634.64 186.7 3.05 594.2 201.1 2.68 552.01 217.1 2.32 200 739.41 193.3 3.39 696.87 206.9 3.01 652.92 222.3 2.65 605.46 239.5 2.3 250 835.75 210.2 3.51 785.83 226 3.1 734.14 243.9 2.71 680.35 263.8 2.34 275 939.12 233.4 3.55 883.92 251.3 3.14 827.67 271.4 2.75 768.6 293.7 2.38 300 1053.04 266.9 3.46 989.75 286.7 3.06 924.71 309.1 2.68 855.79 334 2.31 350 1266.11 314.2 3.54 1192.28 338 3.13 1116.33 364.9 2.74 1036.17 394.7 2.37 140 557.64 136.4 3.6 524.24 146.4 3.18 489.43 157.6 2.78 453.92 170.2 2.41 155 613.19 148 3.65 576.98 159 3.22 539.71 171.5 2.82 501.38 185.4 2.45 170 671.91 160 3.7 632.88 172.1 3.27 592.45 185.7 2.87 551.31 200.8 2.49 185 721.48 180.5 3.57 679.99 193.4 3.17 637.45 207.9 2.79 592.45 224.1 2.42 200 791.1 200.9 3.51 746.1 214.6 3.12 699.33 230.1 2.75 649.05 247.4 2.4 250 896.23 217.9 3.65 843.14 233.9 3.23 788.64 251.9 2.83 731.68 271.9 2.45 275 1005.58 242 3.69 947.56 259.9 3.26 887.79 280.2 2.86 825.91 302.6 2.49 300 1127.93 276.7 3.59 1061.13 296.6 3.18 992.22 319.2 2.79 919.43 344.2 2.42 350 1354.71 325.7 3.67 1277.01 349.6 3.25 1196.85 376.6 2.86 1112.46 406.6 2.48 140 597.02 141.4 3.73 561.51 151.5 3.31 524.94 162.8 2.9 487.32 175.5 2.52 155 655.73 153.4 3.78 617.41 164.5 3.35 578.38 177 2.94 537.6 191 2.56 170 718.32 165.8 3.83 676.83 178 3.4 634.29 191.6 2.98 590.69 206.8 2.6 185 770.71 187.4 3.69 727.11 200.4 3.28 681.75 214.9 2.89 634.29 231.2 2.52 200 844.19 208.8 3.62 796.73 222.5 3.23 747.5 238.1 2.85 694.06 255.5 2.49 2.56 COP³ 250 958.46 226 3.78 902.56 242.1 3.35 845.25 260.1 2.94 784.77 280.2 275 1074.84 250.9 3.82 1013.31 268.9 3.39 950.37 289.2 2.98 884.98 311.8 2.59 300 1205.64 286.9 3.72 1135.32 307 3.3 1062.54 329.6 2.9 985.18 354.7 2.52 350 1446.48 337.6 3.8 1364.56 361.7 3.37 1280.18 388.8 2.97 1190.87 418.9 2.59 1. Ratings based on TOPSS version 140: evaporator fouling factor of 0.01761m²°C/kW, evaporator temperature drop of 5°C, and 2 pass evaporator configuration. Consult Trane representative for additional performance information. 2. kW input is for compressors only. 3. COP = Coefficient of Performance. Power inputs include compressors and control power. 4. Interpolation between points is permissible. Extrapolation is not permitted. RLC-PRC006M-EN 29 Controls LCD Touch Screen Display The standard DynaView display provided with theTrane CH530 control panel features an LCD touch screen that is navigated by file tabs.This is an advanced interface that allows the user to access any important information concerning setpoints, active temperatures, modes, electrical data, pressure, and diagnostics. It uses full text display available in 19 languages. Display Features Include: • LCD touch screen with LED backlighting, for scrolling access to input and output operating information • Single screen, folder/tab style display of all available information on individual components (evaporator, condenser, compressor, etc.) • Password entry/lockout system to enable or disable display • Automatic and immediate stop capabilities for standard or immediate manual shutdown • Fast, easy access to available chiller data in tabbed format, including: • Modes of operation, including normal cooling as well as ice making • Water temperatures and setpoints • Loading and limiting status and setpoints • Outdoor air temperature • Start/stop differential timers • Pump status and override • Chilled water reset settings • Optional external setpoints, including: • Chilled water, demand limit, ice building Reports, listed on a single tabbed screen for easy access, including: • ASHRAE, containing all guideline 3 report information • Evaporator, condenser, compressor Evaporator, condenser, and compressor reports containing all operational information on individual components, including: • Water temperatures, refrigerant pressures, temperatures, and approach • Flow switch status, EXV position, compressor starts and run time Alarm and diagnostic information, including: • Flashing alarms with touch screen button for immediate address of alarm condition • Scrollable list of last ten active diagnostics • Specific information on applicable diagnostic from list of over one hundred • Automatic or manual resetting diagnostic types Adaptive Controls Adaptive Controls directly sense the control variables that govern the operation of the chiller: evaporator pressure and condenser pressure. When any one of these variables approaches a limit condition when damage may occur to the unit or shutdown on a safety, Adaptive Controls takes corrective action to avoid shutdown and keep the chiller operating.This happens through combined actions of compressor and/or fan staging. Whenever possible, the chiller is allowed to continue making chilled water.This keeps cooling capacity available until the problem can be solved. Overall, the safety controls help keep the building or process running and out of trouble. 30 RLC-PRC006M-EN Controls Stand Alone Controls Single chillers installed in applications without a building management system is simple to install and control: only a remote auto/stop for scheduling is required for unit operation. Signals from the chilled water pump contactor auxiliary, or a flow switch, are wired to the chilled water flow interlock. Signals from a time clock or some other remote device are wired to the external auto/stop input. • External Auto/Stop - A job site provided contact closure will turn the unit on and off. • Chilled Water Flow Interlock - A job site provided contact closure from a chilled water pump contactor or a flow switch is required and will allow unit operation if a load exists.This feature will allow the unit to run in conjunction with the pump system. • External Interlock - A job site supplied contact opening wired to this input will turn the unit off and require a manual reset of the unit microcomputer.This closure is typically triggered by a job site supplied system such as a fire alarm. • Chilled Water Pump Control - Unit controls provide an output to control the chilled water pump(s). One contact closure to the chiller is all that is required to initiate the chilled water system. Chilled water pump control by the chiller is a requirement on the Air-Cooled Series R. • Chilled WaterTemperature Reset -The reset can be based on return water temperature or outdoor air temperature. Hardwire Points Microcomputer controls allow simple interface with other control systems, such as time clocks, building automation systems, and ice storage systems via hardwire points.This means you have the flexibility to meet job requirements while not having to learn a complicated control system. Remote devices are wired from the control panel to provide auxiliary control to a building automation system. Inputs and outputs can be communicated via a typical 4–20 mA electrical signal, an equivalent 2–10 Vdc signal, or by utilizing contact closures. Contact closures may be used to trigger job site supplied alarm lights or alarm bells. This setup has the same features as a stand alone water chiller, with the possibility of having additional optional features: • Circuit enable/disable • Ice making enable/status • External chilled water setpoint, external demand limit setpoint • Alarm indication contacts provides three single pole double throw contact closures to indicate: compressor on/off status, compressor running at maximum capacity, failure has occurred (ckt 1/ckt 2) BACnet Interface BACnet interface capabilities are available, with communication link via single twisted-pair wiring to a factory-installed and tested communication board. Required features: • BACnet Interface (selectable option with chiller) BACnet is a data communication protocol for building automation and control networks developed by American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE). LonTalk LCI-C Interface LonTalk (LCI-C) communications capabilities are available, with communication link via single twisted pair wiring to factory installed, tested communication board. • RLC-PRC006M-EN Required features: LonTalk/Tracer Summit Interface (selectable option with chiller) 31 Controls LonTalk is a communications protocol developed by the Echelon Corporation.The LonMark association develops control profiles using the LonTalk communication protocol. LonTalk is a unit level communications protocol. LonTalk Communications Interface for Chillers (LCI-C) provides a generic automation system with the LonMark chiller profile inputs/outputs. In addition to the standard points,Trane provides other commonly used network output variables for greater interoperability with any automation system. The complete reference list ofTrane LonTalk points is available on the LonMark web site. Trane controls or another vendor’s system can use the predefined list of points with ease to give the operator a complete picture of how the system is running Tracer Summit The chiller plant control capabilities of theTraneTracer Summit building automation system are unequaled in the industry.Trane’s depth of experience in chillers and controls makes us a well qualified choice for automation of chiller plants using air-cooled chillers. Our chiller plant automation software is fully pre-engineered and tested. Required features: • LonTalk/Tracer Summit Interface (selectable option with chiller) • Building Control Unit (external device required) Energy Efficiency • Sequences starting of chillers to optimize the overall chiller plant energy efficiency – Individual chillers operate as base, peak, or swing based on capacity and efficiency – Automatically rotates individual chiller operation to equalize runtime and wear between chillers. – Evaluates and selects the lowest energy consumption alternative from an overall system perspective. Easy Operation and Maintenance • Remote monitoring and control • Displays both current operation conditions and scheduled automated control actions • Concise reports assist in planning for preventative maintenance and verifying performance • Alarm notification and diagnostic messages aid in quick and accurate troubleshooting Tracer SC TheTracer SC system controller acts as the central coordinator for all individual equipment devices on aTracer building automation system.TheTracer SC scans all unit controllers to update information and coordinate building control, including building subsystems such as VAV and chiller water systems. With this system option, the full breadth ofTrane’s HVAC and controls experience are applied to offer solutions to many facility issues.The LAN allows building operators to manage these varied components as one system from any personal computer with web access. The benefits of this system are: 32 • Improved usability with automatic data collection, enhanced data logging, easier to create graphics, simpler navigation, pre-programmed scheduling, reporting, and alarm logs. • Flexible technology allows for system sizes from 30-120 unit controllers with any combination of LonTalk or BACnet unit controllers. • LEED certification through site commissioning report, energy data collection measurement, optimizing energy performance, and maintaining indoor air quality. • Energy savings programs include: fan pressure optimization, ventilation reset, and chiller plant control (adds and subtracts chillers to meet cooling loads). RLC-PRC006M-EN Electrical Data Table 14. Standard efficiency — all ambient options # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 200/60/3 230/60/3 140 380/60/3 460/60/3 575/60/3 155 170 185 Cntrl kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 1 2 8 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 2 2 4/4 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 1 2 8 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 2 2 4/4 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 1 2 8 1.5 3.5 3.7 0.83 142/142 973/973 316/316 2 2 4/4 1.5 3.5 3.7 0.83 142/142 973/973 316/316 1 2 8 1.5 3 3.7 0.83 118/118 774/774 252/252 2 2 4/4 1.5 3 3.7 0.83 118/118 774/774 252/252 1 2 8 1.5 2.5 3.0 0.83 94/94 631/631 205/205 2 2 4/4 1.5 2.5 3.0 0.83 94/94 631/631 205/205 200/60/3 1 2 9 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 200/60/3 2 2 5/4 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 230/60/3 1 2 9 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 230/60/3 2 2 5/4 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 380/60/3 1 2 9 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 380/60/3 2 2 5/4 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 460/60/3 1 2 9 1.5 3 3.7 0.83 139/118 878/774 285/252 460/60/3 2 2 5/4 1.5 3 3.7 0.83 139/118 878/774 285/252 575/60/3 1 2 9 1.5 2.5 3.0 0.83 111/94 705/631 229/205 575/60/3 2 2 5/4 1.5 2.5 3.0 0.83 111/94 705/631 229/205 200/60/3 1 2 10 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 200/60/3 2 2 5/5 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 230/60/3 1 2 10 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 230/60/3 2 2 5/5 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 380/60/3 1 2 10 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 380/60/3 2 2 5/5 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 460/60/3 1 2 10 1.5 3 3.7 0.83 139/139 878/878 285/285 460/60/3 2 2 5/5 1.5 3 3.7 0.83 139/139 878/878 285/285 575/60/3 1 2 10 1.5 2.5 3.0 0.83 111/111 705/705 229/229 575/60/3 2 2 5/5 1.5 2.5 3.0 0.83 111/111 705/705 229/229 200/60/3 1 2 11 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 200/60/3 2 2 6/5 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 230/60/3 1 2 11 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 230/60/3 2 2 6/5 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 380/60/3 1 2 11 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 380/60/3 2 2 6/5 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 460/60/3 1 2 11 1.5 3 3.7 0.83 168/139 1065/878 346/285 460/60/3 2 2 6/5 1.5 3 3.7 0.83 168/139 1065/878 346/285 575/60/3 1 2 11 1.5 2.5 3.0 0.83 134/111 853/705 277/229 575/60/3 2 2 6/5 1.5 2.5 3.0 0.83 134/111 853/705 277/229 RLC-PRC006M-EN MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 665 800 368/364 600/600 586 800 324/321 500/500 350 450 194/192 300/300 293 400 162/160 250/250 234 300 129/128 200/200 734 1000 437/364 700/600 646 800 384/321 600/500 386 500 230/192 350/300 322 450 191/160 300/250 258 350 153/128 250/200 791 1000 437/433 700/700 696 800 384/381 600/600 416 500 230/228 350/350 346 450 191/189 300/300 277 350 153/152 250/250 880 1200 526/433 800/700 775 1000 463/381 700/600 463 600 277/228 450/350 385 500 231/189 350/300 308 400 184/152 300/250 33 Electrical Data Table 14. Standard efficiency — all ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 200 225 275 34 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 200/60/3 1 2 12 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 200/60/3 2 2 6/6 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 230/60/3 1 2 12 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 230/60/3 2 2 6/6 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 380/60/3 1 2 12 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 380/60/3 2 2 6/6 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 460/60/3 1 2 12 1.5 3 3.7 0.83 168/168 1065/1065 346/346 460/60/3 2 2 6/6 1.5 3 3.7 0.83 168/168 1065/1065 346/346 575/60/3 1 2 12 1.5 2.5 3.0 0.83 134/134 853/853 277/277 575/60/3 2 2 6/6 1.5 2.5 3.0 0.83 134/134 853/853 277/277 200/60/3 1 2 13 1.5 6.5 7.3 0.83 459/386 2525/2525 821/821 200/60/3 2 2 7/6 1.5 6.5 7.3 0.83 459/386 2525/2525 821/821 230/60/3 1 2 13 1.5 6.5 7.3 0.83 399/336 2126/2126 691/691 230/60/3 2 2 7/6 1.5 6.5 7.3 0.83 399/336 2126/2126 691/691 380/60/3 1 2 13 1.5 3.5 3.7 0.83 242/203 1306/1306 424/424 380/60/3 2 2 7/6 1.5 3.5 3.7 0.83 242/203 1306/1306 424/424 460/60/3 1 2 13 1.5 3 3.7 0.83 200/168 1065/1065 346/346 460/60/3 2 2 7/6 1.5 3 3.7 0.83 200/168 1065/1065 346/346 575/60/3 1 2 13 1.5 2.5 3.0 0.83 160/134 853/853 277/277 575/60/3 2 2 7/6 1.5 2.5 3.0 0.83 160/134 853/853 277/277 200/60/3 1 2 14 1.5 6.5 7.3 0.83 459/459 2525/2525 821/821 200/60/3 250 Cntrl kVA3 2 2 7/7 1.5 6.5 7.3 0.83 459/459 2525/2525 821/821 230/60/3 1 2 14 1.5 6.5 7.3 0.83 399/399 2126/2126 691/691 230/60/3 2 2 7/7 1.5 6.5 7.3 0.83 399/399 2126/2126 691/691 380/60/3 1 2 14 1.5 3.5 3.7 0.83 242/242 1306/1306 424/424 380/60/3 2 2 7/7 1.5 3.5 3.7 0.83 242/242 1306/1306 424/424 460/60/3 1 2 14 1.5 3 3.7 0.83 200/200 1065/1065 346/346 460/60/3 2 2 7/7 1.5 3 3.7 0.83 200/200 1065/1065 346/346 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 952 1200 526/522 800/800 839 1000 463/460 700/700 501 700 277/275 450/450 417 500 231/229 350/350 334 450 184/183 300/300 1050 1200 624/522 1000/ 800 924 1200 549/460 800/700 554 700 329/275 500/450 460 600 274/229 450/350 369 500 219/183 350/300 1129 1200 624/620 1000/ 1000 994 1200 549/545 800/800 596 800 329/327 500/500 495 600 274/272 450/450 575/60/3 1 2 14 1.5 2.5 3.0 0.83 160/160 853/853 277/277 575/60/3 2 2 7/7 1.5 2.5 3.0 0.83 160/160 853/853 277/277 397 500 200/60/3 1 200/60/3 2 2156-2156/2525 701-701/821 791/526 1756-1756/2126 571-571/691 696/463 800/700 416/277 500/450 219/218 350/350 n/a 3 10/6 1.5 6.5 7.3 1.2 320-320/386 3 10/6 1.5 6.5 7.3 1.2 278-278/336 230/60/3 1 230/60/3 2 380/60/3 1 380/60/3 2 3 10/6 1.5 3.5 3.7 1.2 168-168/203 1060-1060/1306 345-345/424 460/60/3 1 3 16 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 460/60/3 2 3 10/6 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 1000/ 800 n/a n/a 575/60/3 1 3 16 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 575/60/3 2 3 10/6 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 543 700 346/231 450/350 436 500 277/184 350/300 RLC-PRC006M-EN Electrical Data Table 14. Standard efficiency — all ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 300 350 400 450 200/60/3 1 200/60/3 2 230/60/3 1 230/60/3 2 Cntrl kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 2525-2525/2525 821-821/821 952/526 1200/ 800 2126-2126/2126 691-691/691 839/463 1000/ 700 501/277 700/450 n/a 3 12/6 1.5 6.5 7.3 1.2 386-386/386 3 12/6 1.5 6.5 7.3 1.2 336-336/336 n/a 380/60/3 1 380/60/3 2 3 12/6 1.5 3.5 3.7 1.2 203-203/203 n/a 1306-1306/1306 424-424/424 460/60/3 1 3 18 1.5 3 3.7 1.2 168-168/168 1065-1065/1065 346-346/346 460/60/3 2 3 12/6 1.5 3 3.7 1.2 168-168/168 1065-1065/1065 346-346/346 607 700 417/231 500/350 575/60/3 1 3 18 1.5 2.5 3.0 1.2 134-134/134 853-853/853 277-277/277 575/60/3 2 3 12/6 1.5 2.5 3.0 1.2 134-134/134 853-853/853 277-277/277 487 600 200/60/3 1 200/60/3 2 2525-2525/2525 821-821/821 1129/ 526 1200/ 800 230/60/3 1 230/60/3 2 2126-2126/2126 691-691/691 994/463 1200/ 700 596/277 800/450 334/184 450/300 n/a 3 14/6 1.5 6.5 7.3 1.2 459-459/386 n/a 3 14/6 1.5 6.5 7.3 1.2 399-399/336 380/60/3 1 380/60/3 2 3 14/6 1.5 3.5 3.7 1.2 242-242/203 n/a 1306-1306/1306 424-424/424 460/60/3 1 3 20 1.5 3 3.7 1.2 200-200/168 1065-1065/1065 346-346/346 460/60/3 2 3 14/6 1.5 3 3.7 1.2 200-200/168 1065-1065/1065 346-346/346 684 800 495/231 600/350 575/60/3 1 3 20 1.5 2.5 3.0 1.2 160-160/134 853-853/853 277-277/277 575/60/3 2 3 14/6 1.5 2.5 3.0 1.2 160-160/134 853-853/853 277-277/277 200/60/3 1 2525-2525/ 2525-2525 821-821/ 821-821 952/952 1200/ 1200 2126-2126/ 2126-2126 691-691/ 691-6/91 839/839 1000/ 1000 501/501 700/700 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 550 700 397/184 500/300 n/a 4 12/12 1.5 6.5 7.3 1.59 386-386/ 386-386 4 12/12 1.5 6.5 7.3 1.59 336-336/ 336-336 1306-1306/ 1306-1306 424-424/ 424-424 n/a n/a 380/60/3 2 4 12/12 1.5 3.5 3.7 1.59 203-203/ 203-203 460/60/3 1 4 24 1.5 3 3.7 1.59 168-168/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 460/60/3 2 4 12/12 1.5 3 3.7 1.59 168-168/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 575/60/3 1 4 24 1.5 2.5 3.0 1.59 134-134/134-134 853-853/853-853 277-277/277-277 575/60/3 2 4 12/12 1.5 2.5 3.0 1.59 134-134/134-134 853-853/853-853 277-277/277-277 334/334 450/450 200/60/3 1 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 793 800 417/417 500/500 637 700 n/a 4 14/12 1.5 6.5 7.3 1.59 459-459/ 386-386 1.59 399-399/ 336-336 2525-2525/ 2525-2525 821-821/ 821-821 1129/ 952 1200/ 1200 2126-2126/ 2126-2126 691-691/ 691-691 994/839 1200/ 1000 1306-1306/ 1306-1306 424-424/ 424-424 596/501 800/700 n/a 4 14/12 1.5 6.5 7.3 n/a 380/60/3 2 4 14/12 1.5 3.5 3.7 1.59 242-242/ 203-203 460/60/3 1 4 26 1.5 3 3.7 1.59 200-200/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 460/60/3 2 4 14/12 1.5 3 3.7 1.59 200-200/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 575/60/3 1 4 26 1.5 2.5 3.0 1.59 160-160/134-134 853-853/853-853 277-277/277-277 575/60/3 2 4 14/12 1.5 2.5 3.0 1.59 160-160/134-134 853-853/853-853 277-277/277-277 397/334 500/450 RLC-PRC006M-EN 871 1000 495/417 600/500 699 800 35 Electrical Data Table 14. Standard efficiency — all ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 200/60/3 500 Cntrl kVA3 RLA4 Ckt1/Ckt2 1 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 2525-2525/ 2525-2525 821-821/ 821-821 1129/ 1129 1200/ 1200 2126-2126/ 2126-2126 691-691/ 691-691 994/994 1200/ 1200 n/a 4 14/14 1.5 6.5 7.3 1.59 459-459/ 459-459 4 14/14 1.5 6.5 7.3 1.59 399-399/ 399-399 1306-1306/ 1306-1306 424-424/424-424 596/596 800/800 n/a n/a 380/60/3 2 4 14/14 1.5 3.5 3.7 1.59 242-242/ 242-242 460/60/3 1 4 28 1.5 3 3.7 1.59 200-200/ 200-200 1065-1065/ 1065-1065 346-346/346-346 460/60/3 2 4 14/14 1.5 3 3.7 1.59 200-200/ 200-200 1065-1065/ 1065-1065 346-346/346-346 495/495 600/600 575/60/3 1 4 28 1.5 2.5 3.0 1.59 160-160/160-160 853-853/853-853 277-277/277-277 575/60/3 2 4 14/14 1.5 2.5 3.0 1.59 160-160/160-160 853-853/853-853 277-277/277-277 397/397 500/500 941 756 1000 800 Notes: 1. Voltage Utilization Range: +/- 10% of rated voltage. Rated voltage (use range): 200/60/3 (180-220), 230/60/3 (208-254), 380/60/3 (342-418), 460/60/ 3 (414-506), 575/60/3 (516-633) 2. As standard, 140-250 ton units have a single point power connection. Optional dual point power connections are available. As standard, 275-500 ton unitshave dual point power connections. Optional single point power connections are available on 460V and 575V/60 Hz units. 3. Control VA includes operational controls only. It does not include evaporator heaters. A separate 115/60/1, 20 ampcustomer provided power connection is required to power the evaporator heaters (1640 watts). 4. RLA - Rated Load Amps 5. XLRA - Locked Rotor Amps - based on full winding (x-line) start units). YLRA for wye-delta starters is ~1/3 of LRA of x-line units. 6. MCA - Minimum Circuit Ampacity - 125 percent of largest compressor RLA plus 100 percent of all other loads. 7. Max fuse or MOPD = 225 percent of the largest compressor RLA plus 100 percent of the second compressor RLA, plus the sum of the condenser fan FLA. (Use FLA per circuit, NOT FLA for the entire unit). 8. Local codes may take precedence. 9. All ambient means standard, low, high and wide ambient options. 36 RLC-PRC006M-EN Electrical Data Table 15. High efficiency — standard and low ambient options # # Fan Unit Rated # Power Ckt1/ Size Voltage1 Conn2 Comp Ckt2 140 155 170 185 Fan Fan VFD Cntrl kW FLA Input kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 10 1.5 6.5 7.3 0.83 259/259 1845/1845 600/600 653 800 200/60/3 2 2 5/5 1.5 6.5 7.3 0.83 259/259 1845/1845 600/600 361/357 600/600 230/60/3 1 2 10 1.5 6.5 7.3 0.83 225/225 1556/1556 506/506 576 800 230/60/3 2 2 5/5 1.5 6.5 7.3 0.83 225/225 1556/1556 506/506 318/315 500/500 380/60/3 1 2 10 1.5 3.5 3.7 0.83 136/136 973/973 316/316 344 450 380/60/3 2 2 5/5 1.5 3.5 3.7 0.83 136/136 973/973 316/316 190/188 300/300 460/60/3 1 2 10 1.5 3 3.7 0.83 113/113 774/774 252/252 287 400 460/60/3 2 2 5/5 1.5 3 3.7 0.83 113/113 774/774 252/252 159/157 250/250 575/60/3 1 2 10 1.5 2.5 3.0 0.83 90/90 631/631 205/205 230 300 575/60/3 2 2 5/5 1.5 2.5 3.0 0.83 90/90 631/631 205/205 127/126 200/200 200/60/3 1 2 11 1.5 6.5 7.3 0.83 305/259 2156/1845 701/600 717 1000 200/60/3 2 2 6/5 1.5 6.5 7.3 0.83 305/259 2156/1845 701/600 425/357 700/600 230/60/3 1 2 11 1.5 6.5 7.3 0.83 265/225 1756/1556 571/506 633 800 230/60/3 2 2 6/5 1.5 6.5 7.3 0.83 265/225 1756/1556 571/506 375/315 600/500 380/60/3 1 2 11 1.5 3.5 3.7 0.83 161/136 1060/973 345/316 378 500 380/60/3 2 2 6/5 1.5 3.5 3.7 0.83 161/136 1060/973 345/316 225/188 350/300 460/60/3 1 2 11 1.5 3 3.7 0.83 133/113 878/774 285/252 315 400 460/60/3 2 2 6/5 1.5 3 3.7 0.83 133/113 878/774 285/252 187/157 300/250 575/60/3 1 2 11 1.5 2.5 3.0 0.83 106/90 705/631 229/205 254 350 575/60/3 2 2 6/5 1.5 2.5 3.0 0.83 106/90 705/631 229/205 149/126 250/200 200/60/3 1 2 12 1.5 6.5 7.3 0.83 305/305 2156/2156 701/701 770 1000 200/60/3 2 2 6/6 1.5 6.5 7.3 0.83 305/305 2156/2156 701/701 425/421 700/700 230/60/3 1 2 12 1.5 6.5 7.3 0.83 265/265 1756/1756 571/571 679 800 230/60/3 2 2 6/6 1.5 6.5 7.3 0.83 265/265 1756/1756 571/571 375/371 600/600 380/60/3 1 2 12 1.5 3.5 3.7 0.83 161/161 1060/1060 345/345 407 500 380/60/3 2 2 6/6 1.5 3.5 3.7 0.83 161/161 1060/1060 345/345 225/222 350/350 460/60/3 1 2 12 1.5 3 3.7 0.83 133/133 878/878 285/285 338 450 460/60/3 2 2 6/6 1.5 3 3.7 0.83 133/133 878/878 285/285 187/185 300/300 575/60/3 1 2 12 1.5 2.5 3.0 0.83 106/106 705/705 229/229 271 350 575/60/3 2 2 6/6 1.5 2.5 3.0 0.83 106/106 705/705 229/229 149/148 250/250 200/60/3 1 2 13 1.5 6.5 7.3 0.83 373-305 2525/2156 821/701 861 1200 200/60/3 2 2 7/6 1.5 6.5 7.3 0.83 373/305 2525/2156 821/701 517/421 800/700 230/60/3 1 2 13 1.5 6.5 7.3 0.83 324-265 2126/1756 691/571 760 1000 230/60/3 2 2 7/6 1.5 6.5 7.3 0.83 324/265 2126/1756 691/571 455/371 700/600 380/60/3 1 2 13 1.5 3.5 3.7 0.83 196-161 1306/1060 424/345 454 600 380/60/3 2 2 7/6 1.5 3.5 3.7 0.83 196/161 1306/1060 424/345 272/222 450/350 460/60/3 1 2 13 1.5 3 3.7 0.83 162-133 1065/878 346/285 378 500 460/60/3 2 2 7/6 1.5 3 3.7 0.83 162/133 1065/878 346/285 226/185 350/300 575/60/3 1 2 13 1.5 2.5 3.0 0.83 130-106 853/705 277/229 305 400 575/60/3 2 2 7/6 1.5 2.5 3.0 0.83 130/106 853/705 277/229 182/148 300/250 RLC-PRC006M-EN 37 Electrical Data Table 15. High efficiency — standard and low ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Size Voltage1 Conn2 Comp Ckt2 200 225 250 275 38 Fan Fan VFD Cntrl kW FLA Input kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 14 1.5 6.5 7.3 0.83 373/373 2525/2525 821/821 936 1200 200/60/3 2 2 7/7 1.5 6.5 7.3 0.83 373/373 2525/2525 821/821 517/513 800/800 230/60/3 1 2 14 1.5 6.5 7.3 0.83 324/324 2126/2126 691/691 825 1000 230/60/3 2 2 7/7 1.5 6.5 7.3 0.83 324/324 2126/2126 691/691 455/451 700/700 380/60/3 1 2 14 1.5 3.5 3.7 0.83 196/196 1306/1306 424/424 493 600 380/60/3 2 2 7/7 1.5 3.5 3.7 0.83 196/196 1306/1306 424/424 272/270 450/450 460/60/3 1 2 14 1.5 3 3.7 0.83 162/162 1065/1065 346/346 410 500 460/60/3 2 2 7/7 1.5 3 3.7 0.83 162/162 1065/1065 346/346 226/224 350/350 575/60/3 1 2 14 1.5 2.5 3.0 0.83 130/130 853/853 277/277 331 450 575/60/3 2 2 7/7 1.5 2.5 3.0 0.83 130/130 853/853 277/277 182/181 300/300 200/60/3 1 2 14 1.5 6.5 7.3 0.83 447/373 2525/2525 821/821 1028 1200 200/60/3 2 2 8/6 1.5 6.5 7.3 0.83 447/373 2525/2525 821/821 615/506 1000/800 230/60/3 1 2 14 1.5 6.5 7.3 0.83 388/324 2126/2126 691/691 904 1200 230/60/3 2 2 8/6 1.5 6.5 7.3 0.83 388/324 2126/2126 691/691 541/445 800/700 380/60/3 1 2 14 1.5 3.5 3.7 0.83 235/196 1306/1306 424/424 541 700 380/60/3 2 2 8/6 1.5 3.5 3.7 0.83 235/196 1306/1306 424/424 324/266 500/450 460/60/3 1 2 14 1.5 3 3.7 0.83 194/162 1065/1065 346/346 449 600 460/60/3 2 2 8/6 1.5 3 3.7 0.83 194/162 1065/1065 346/346 268/221 450/350 575/60/3 1 2 14 1.5 2.5 3.0 0.83 155/130 853/853 277/277 361 500 575/60/3 2 2 8/6 1.5 2.5 3.0 0.83 155/130 853/853 277/277 215/178 350/300 200/60/3 1 2 16 1.5 6.5 7.3 0.83 447/447 2525/2525 821/821 1115 1200 200/60/3 2 2 8/8 1.5 6.5 7.3 0.83 447/447 2525/2525 821/821 616/612 1000/1000 230/60/3 1 2 16 1.5 6.5 7.3 0.83 388/388 2126/2126 691/691 982 1200 230/60/3 2 2 8/8 1.5 6.5 7.3 0.83 388/388 2126/2126 691/691 541/538 800/800 380/60/3 1 2 16 1.5 3.5 3.7 0.83 235/235 1306/1306 424/424 587 800 380/60/3 2 2 8/8 1.5 3.5 3.7 0.83 235/235 1306/1306 424/424 324/322 500/500 460/60/3 1 2 16 1.5 3 3.7 0.83 194/194 1065/1065 346/346 488 600 460/60/3 2 2 8/8 1.5 3 3.7 0.83 194/194 1065/1065 346/346 269/267 450/450 575/60/3 1 2 7/4 1.5 2.5 3.0 0.83 155/155 853/853 277/277 391 500 575/60/3 2 2 8/8 1.5 2.5 3.0 0.83 155/155 853/853 277/277 216/214 350/350 200/60/3 1 200/60/3 2 3 12/6 1.5 6.5 7.3 1.2 305-305/373 2156-2156/2525 701-701/821 770/510 1000/800 230/60/3 1 230/60/3 2 1756-1756/2126 571-571/691 679/448 800/700 380/60/3 1 380/60/3 2 3 12/6 1.5 3.5 3.7 1.2 161-161/196 1060-1060/1306 345-345/424 407/268 500/450 460/60/3 1 3 18 1.5 3 3.7 1.2 133-133/162 878-878/1065 285-285/346 529 600 460/60/3 2 3 12/6 1.5 3 3.7 1.2 133-133/162 878-878/1065 285-285/346 338/223 450/350 575/60/3 1 3 18 1.5 2.5 3.0 1.2 106-106/130 705-705/853 229-229/277 426 500 575/60/3 2 3 12/6 1.5 2.5 3.0 1.2 106-106/130 705-705/853 229-229/277 271/179 350/300 n/a n/a 3 12/6 1.5 6.5 7.3 1.2 265-265/324 n/a RLC-PRC006M-EN Electrical Data Table 15. High efficiency — standard and low ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Size Voltage1 Conn2 Comp Ckt2 300 350 400 Fan Fan VFD Cntrl kW FLA Input kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 2525-2525/2525 821-821/821 936/510 1200/800 2126-2126/2126 691-691/691 825/448 1000/700 600/450 200/60/3 1 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 380/60/3 2 3 14/6 1.5 3.5 3.7 1.2 196-196/196 1306-1306/1306 424-424/424 493/268 460/60/3 1 3 20 1.5 3 3.7 1.2 162-162/162 1065-1065/1065 346-346/346 592 700 460/60/3 2 3 14/6 1.5 3 3.7 1.2 162-162/162 1065-1065/1065 346-346/346 410/223 500/350 575/60/3 1 3 20 1.5 2.5 3.0 1.2 130-130/130 853-853/853 277-277/277 477 600 575/60/3 2 3 14/6 1.5 2.5 3.0 1.2 130-130/130 853-853/853 277-277/277 330/179 450/300 200/60/3 1 1.2 305-305/ 305-305 2156-2156/ 2156-2156 701-701/ 701-701 770/770 1000/1000 1.2 265-265/ 265-265 1756-1756/ 1756-1756 571-571/ 571-571 679/679 800/800 200/60/3 2 230/60/3 1 n/a 3 14/6 1.5 6.5 7.3 1.2 373-373/373 n/a 3 14/6 1.5 6.5 7.3 1.2 324-324/324 n/a n/a 4 12/12 1.5 6.5 7.3 n/a 230/60/3 2 380/60/3 1 380/60/3 2 4 12/12 1.5 3.5 3.7 1.2 161-161/ 161-161 1060-1060/ 1060-1060 345-345/ 345-345 407/407 500/500 460/60/3 1 4 24 1.5 3 3.7 1.2 133-133/ 133-133 878-878/878-878 285-285/ 285-285 644 700 460/60/3 2 4 12/12 1.5 3 3.7 1.2 133-133/ 133-133 878-878/878-878 285-285/ 285-285 338/338 450/450 575/60/3 1 4 24 1.5 2.5 3.0 1.2 106-106/ 106-106 705-705/705-705 229-229/ 229-229 515 600 1.2 106-106/ 106-106 705-705/705-705 229-229/ 229-229 271/271 350/350 1.59 373-373/ 373-373 2525-2525/ 2525-2525 821-821/ 821-821 936/936 1200/1200 1.59 324-324/ 324-324 2126-2126/ 2126-2126 691-691/ 691-691 825/825 1000/1000 575/60/3 2 200/60/3 1 200/60/3 2 230/60/3 1 4 12/12 1.5 6.5 7.3 n/a 4 12/12 1.5 2.5 3.0 n/a 4 14/14 1.5 6.5 7.3 n/a 230/60/3 2 4 14/14 1.5 6.5 7.3 380/60/3 1 380/60/3 2 4 14/14 1.5 3.5 3.7 1.59 196-196/ 196-196 1306-1306/ 1306-1306 424-424/ 424-424 493/493 600/600 460/60/3 1 4 28 1.5 3 3.7 1.59 162-162/ 162-162 1065-1065/ 1065-1065 346-346/ 346-346 779 800 460/60/3 2 4 14/14 1.5 3 3.7 1.59 162-162/ 162-162 1065-1065/ 1065-1065 346-346/ 346-346 410/410 500/500 853-853/ 853-853 277-277/ 277-277 627 700 853-853/ 853-853 277-277/ 277-277 330/330 450/450 n/a 575/60/3 1 4 28 1.5 2.5 3.0 1.59 130-130/ 130-130 575/60/3 2 4 14/14 1.5 2.5 3.0 1.59 130-130/ 130-130 Notes: 1. Voltage Utilization Range: +/- 10% of rated voltage. Rated voltage (use range): 200/60/3 (180-220), 230/60/3 (208-254), 380/60/3 (342-418), 460/60/3 (414-506), 575/60/3 (516-633) 2. As standard, 140-250 ton units have a single point power connection. Optional dual point power connections are available. As standard, 275-500 ton units have dual point power connections. Optional single point power connections are available on 460V and 575V/60 Hzunits. 3. Control VA includes operational controls only. It does not include evaporator heaters. A separate 115/60/1, 20 amp customer provided power connection is required to power the evaporator heaters (1640 watts). 4. RLA - Rated Load Amps 5. XLRA - Locked Rotor Amps - based on full winding (x-line) start units). YLRA for wye-delta starters is ~1/3 of LRA of x-line units. 6. MCA - Minimum Circuit Ampacity - 125 percent of largest compressor RLA plus 100 percent of all other loads. 7. Max fuse or MOPD = 225 percent of the largest compressor RLA plus 100 percent of the second compressor RLA, plus the sum of the condenser fan FLA. (Use FLA per circuit, NOT FLA for the entire unit). 8. Local codes may take precedence. 9. All ambient means standard, low, high and wide ambient options. RLC-PRC006M-EN 39 Electrical Data Table 16. High efficiency — high and wide ambient options # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 140 155 170 185 40 RLA4 Cntrl kVA3 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 10 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 678 800 200/60/3 2 2 5/5 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 375/371 600/600 230/60/3 1 2 10 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 599 800 230/60/3 2 2 5/5 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 331/327 500/500 380/60/3 1 2 10 1.5 3.5 3.7 0.83 142/142 973/973 316/316 357 450 380/60/3 2 2 5/5 1.5 3.5 3.7 0.83 142/142 973/973 316/316 197/195 300/300 460/60/3 1 2 10 1.5 3 3.7 0.83 118/118 774/774 252/252 299 400 460/60/3 2 2 5/5 1.5 3 3.7 0.83 118/118 774/774 252/252 165/163 250/250 575/60/3 1 2 10 1.5 2.5 3.0 0.83 94/94 631/631 205/205 239 300 575/60/3 2 2 5/5 1.5 2.5 3.0 0.83 94/94 631/631 205/205 132/131 225/225 200/60/3 1 2 11 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 747 1000 200/60/3 2 2 6/5 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 444/371 700/600 230/60/3 1 2 11 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 659 800 230/60/3 2 2 6/5 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 391/327 600/500 380/60/3 1 2 11 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 393 500 380/60/3 2 2 6/5 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 233/195 400/300 460/60/3 1 2 11 1.5 3 3.7 0.83 139/118 878/774 285/252 328 450 460/60/3 2 2 6/5 1.5 3 3.7 0.83 139/118 878/774 285/252 194/163 300/250 575/60/3 1 2 11 1.5 2.5 3.0 0.83 111/94 705/631 229/205 263 350 575/60/3 2 2 6/5 1.5 2.5 3.0 0.83 111/94 705/631 229/205 156/131 250/200 200/60/3 1 2 12 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 804 1000 200/60/3 2 2 6/6 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 444/440 700/700 230/60/3 1 2 12 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 709 800 230/60/3 2 2 6/6 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 391/387 600/600 380/60/3 1 2 12 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 423 500 380/60/3 2 2 6/6 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 233/231 400/350 460/60/3 1 2 12 1.5 3 3.7 0.83 139/139 878/878 285/285 352 450 460/60/3 2 2 6/6 1.5 3 3.7 0.83 139/139 878/878 285/285 194/192 300/300 575/60/3 1 2 12 1.5 2.5 3.0 0.83 111/111 705/705 229/229 282 350 575/60/3 2 2 6/6 1.5 2.5 3.0 0.83 111/111 705/705 229/229 156/154 250/250 200/60/3 1 2 13 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 893 1200 200/60/3 2 2 7/6 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 533/440 800/700 230/60/3 1 2 13 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 788 1000 230/60/3 2 2 7/6 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 470/387 800/600 380/60/3 1 2 13 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 470 600 380/60/3 2 2 7/6 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 281/231 450/350 460/60/3 1 2 13 1.5 3 3.7 0.83 168/139 1065/878 346/285 391 500 460/60/3 2 2 7/6 1.5 3 3.7 0.83 168/139 1065/878 346/285 234/192 400/300 575/60/3 1 2 13 1.5 2.5 3.0 0.83 134/111 853/705 277/229 313 450 575/60/3 2 2 7/6 1.5 2.5 3.0 0.83 134/111 853/705 277/229 187/154 300/250 RLC-PRC006M-EN Electrical Data Table 16. High efficiency — high and wide ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 200 225 250 275 RLA4 Cntrl kVA3 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 14 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 965 1200 200/60/3 2 2 7/7 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 533/529 800/800 230/60/3 1 2 14 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 852 1000 230/60/3 2 2 7/7 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 470/466 800/800 380/60/3 1 2 14 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 508 700 380/60/3 2 2 7/7 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 281/278 450/450 460/60/3 1 2 14 1.5 3 3.7 0.83 168/168 1065/1065 346/346 423 500 460/60/3 2 2 7/7 1.5 3 3.7 0.83 168/168 1065/1065 346/346 234/232 400/350 575/60/3 1 2 14 1.5 2.5 3.0 0.83 134/134 853/853 277/277 339 450 575/60/3 2 2 7/7 1.5 2.5 3.0 0.83 134/134 853/853 277/277 187/186 300/300 200/60/3 1 2 14 1.5 6.5 7.3 0.83 459/386 2525/2525 821/821 1056 1200 200/60/3 2 2 8/6 1.5 6.5 7.3 0.83 459/386 2525/2525 821/821 631/522 1000/800 230/60/3 1 2 14 1.5 6.5 7.3 0.83 399/336 2126/2126 691/691 931 1200 230/60/3 2 2 8/6 1.5 6.5 7.3 0.83 399/336 2126/2126 691/691 555/460 800/700 380/60/3 1 2 14 1.5 3.5 3.7 0.83 242/203 1306/1306 424/424 557 700 380/60/3 2 2 8/6 1.5 3.5 3.7 0.83 242/203 1306/1306 424/424 333/275 500/450 460/60/3 1 2 14 1.5 3 3.7 0.83 200/168 1065/1065 346/346 463 600 460/60/3 2 2 8/6 1.5 3 3.7 0.83 200/168 1065/1065 346/346 277/229 450/350 575/60/3 1 2 14 1.5 2.5 3.0 0.83 160/134 853/853 277/277 371 500 575/60/3 2 2 8/6 1.5 2.5 3.0 0.83 160/134 853/853 277/277 222/183 350/300 200/60/3 1 2 16 1.5 6.5 7.3 0.83 459/459 2525/2525 821/821 1142 1600 200/60/3 2 2 8/8 1.5 6.5 7.3 0.83 459/459 2525/2525 821/821 631/627 1000/1000 230/60/3 1 2 16 1.5 6.5 7.3 0.83 399/399 2126/2126 691/691 1007 1200 230/60/3 2 2 8/8 1.5 6.5 7.3 0.83 399/399 2126/2126 691/691 555/552 800/800 380/60/3 1 2 16 1.5 3.5 3.7 0.83 242/242 1306/1306 424/424 603 800 380/60/3 2 2 8/8 1.5 3.5 3.7 0.83 242/242 1306/1306 424/424 333/331 500/500 460/60/3 1 2 16 1.5 3 3.7 0.83 200/200 1065/1065 346/346 501 700 460/60/3 2 2 8/8 1.5 3 3.7 0.83 200/200 1065/1065 346/346 277/275 450/450 575/60/3 1 2 16 1.5 2.5 3.0 0.83 160/160 853/853 277/277 402 500 575/60/3 2 2 8/8 1.5 2.5 3.0 0.83 160/160 853/853 277/277 222/221 350/350 200/60/3 1 200/60/3 2 3 12/6 1.5 6.5 7.3 1.2 320-320/386 2156-2156/2525 701-701/821 804/526 1000/800 230/60/3 1 230/60/3 2 1756-1756/2126 571-571/691 709/463 800/700 380/60/3 1 380/60/3 2 3 12/6 1.5 3.5 3.7 1.2 168-168/203 1060-1060/1306 345-345/424 423/277 500/450 460/60/3 1 3 18 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 549 700 460/60/3 2 3 12/6 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 352/231 450/350 575/60/3 1 3 18 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 441 500 575/60/3 2 3 12/6 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 282/184 350/300 RLC-PRC006M-EN n/a n/a 3 12/6 1.5 6.5 7.3 1.2 278-278/336 n/a 41 Electrical Data Table 16. High efficiency — high and wide ambient options (continued) # # Fan Unit Rated # Power Ckt1/ Fan Fan VFD Size Voltage1 Conn2 Comp Ckt2 kW FLA Input 300 350 400 RLA4 Cntrl kVA3 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 2525-2525/2525 821-821/821 965/526 1200/800 2126-2126/2126 691-691/691 852/463 1000/700 700/450 200/60/3 1 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 380/60/3 2 3 14/6 1.5 3.5 3.7 1.2 203-203/203 1306-1306/1306 424-424/424 508/277 460/60/3 1 3 20 1.5 3 3.7 1.2 168-168/168 1065-1065/1065 346-346/346 612 700 460/60/3 2 3 14/6 1.5 3 3.7 1.2 168-168/168 1065-1065/1065 346-346/346 423/231 500/350 575/60/3 1 3 20 1.5 2.5 3.0 1.2 134-134/134 853-853/853 277-277/277 490 600 575/60/3 2 3 14/6 1.5 2.5 3.0 1.2 134-134/134 853-853/853 277-277/277 339/184 450/300 200/60/3 1 1.2 320-320/ 320-320 2156-2156/ 2156-2156 701-701/ 701-701 804/804 1000/1000 1.2 278-278/ 278-278 1756-1756/ 1756-1756 571-571/ 571-571 709/709 800/800 200/60/3 2 230/60/3 1 n/a 3 14/6 1.5 6.5 7.3 1.2 386-386/386 n/a 3 14/6 1.5 6.5 7.3 1.2 336-336/336 n/a n/a 4 12/12 1.5 6.5 7.3 n/a 230/60/3 2 380/60/3 1 380/60/3 2 4 12/12 1.5 3.5 3.7 1.2 168-168/ 168-168 1060-1060/ 1060-1060 345-345/ 345-345 423/423 500/500 460/60/3 1 4 24 1.5 3 3.7 1.2 139-139/ 139-139 878-878/ 878-878 285-285/ 285-285 669 800 460/60/3 2 4 12/12 1.5 3 3.7 1.2 139-139/ 139-139 878-878/ 878-878 285-285/ 285-285 352/352 450/450 575/60/3 1 4 24 1.5 2.5 3.0 1.2 111-111/ 111-111 705-705/ 705-705 229-229/ 229-229 537 600 1.2 111-111/ 111-111 705-705/ 705-705 229-229/ 229-229 282/282 350/350 1.59 386-386/ 386-386 2525-2525/ 2525-2525 821-821/ 821-821 965/965 1200/1200 1.59 336-336/ 336-336 2126-2126/ 2126-2126 691-691/ 691-691 852/852 1000/1000 575/60/3 2 200/60/3 1 200/60/3 2 230/60/3 1 4 12/12 1.5 6.5 7.3 n/a 4 12/12 1.5 2.5 3.0 n/a 4 14/14 1.5 6.5 7.3 n/a 230/60/3 2 4 14/14 1.5 6.5 7.3 200/60/3 1 380/60/3 2 4 14/14 1.5 3.5 3.7 1.59 203-203/ 203-203 1306-1306/ 1306-1306 424-424/ 424-424 508/508 700/700 460/60/3 1 4 28 1.5 3 3.7 1.59 168-168/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 804 1000 460/60/3 2 4 14/14 1.5 3 3.7 1.59 168-168/ 168-168 1065-1065/ 1065-1065 346-346/ 346-346 423/423 500/500 853-853/ 853-853 277-277/ 277-277 644 700 853-853/ 853-853 277-277/ 277-277 339/339 450/450 n/a 575/60/3 1 4 28 1.5 2.5 3.0 1.59 134-134/ 134-134 575/60/3 2 4 14/14 1.5 2.5 3.0 1.59 134-134/ 134-134 Notes: 1. Voltage Utilization Range: +/- 10% of rated voltage. Rated voltage (use range): 200/60/3 (180-220), 230/60/3 (208-254), 380/60/3 (342-418), 460/60/ 3 (414-506), 575/60/3 (516-633) 2. As standard, 140-250 ton units have a single point power connection. Optional dual point power connections are available. As standard, 275-500 ton unitshave dual point power connections. Optional single point power connections are available on 460V and 575V/60 Hz units. 3. Control VA includes operational controls only. It does not include evaporator heaters. A separate 115/60/1, 20 amp customer provided power connection is required to power the evaporator heaters (1640 watts). 4. RLA - Rated Load Amps 5. XLRA - Locked Rotor Amps - based on full winding (x-line) start units). YLRA for wye-delta starters is ~1/3 of LRA of x-line units. 6. MCA - Minimum Circuit Ampacity - 125 percent of largest compressor RLA plus 100 percent of all other loads. 7. Max fuse or MOPD = 225 percent of the largest compressor RLA plus 100 percent of the second compressor RLA, plus the sum of the condenser fan FLA. (Use FLA per circuit, NOT FLA for the entire unit). 8. Local codes may take precedence. 9. All ambient means standard, low, high and wide ambient options. 42 RLC-PRC006M-EN Electrical Data Table 17. Extra efficiency — high and wide ambient Unit Size 140 155 170 185 # # Fan Rated # Power Ckt1/ Fan Fan VFD Cntrl Voltage1 Conn2 Comp Ckt2 kW FLA Input kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 12 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 691 800 200/60/3 2 2 6/6 1.5 6.5 7.3 0.83 270/270 1845/1845 600/600 381/377 600/600 230/60/3 1 2 12 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 612 800 230/60/3 2 2 6/6 1.5 6.5 7.3 0.83 235/235 1556/1556 506/506 337/334 500/500 380/60/3 1 2 12 1.5 3.5 3.7 0.83 142/142 973/973 316/316 364 500 380/60/3 2 2 6/6 1.5 3.5 3.7 0.83 142/142 973/973 316/316 201/199 300/300 460/60/3 1 2 12 1.5 3 3.7 0.83 118/118 774/774 252/252 305 400 460/60/3 2 2 6/6 1.5 3 3.7 0.83 118/118 774/774 252/252 168/166 250/250 575/60/3 1 2 12 1.5 2.5 3.0 0.83 94/94 631/631 205/205 244 300 575/60/3 2 2 6/6 1.5 2.5 3.0 0.83 94/94 631/631 205/205 134/133 225/225 200/60/3 1 2 13 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 760 1000 200/60/3 2 2 7/6 1.5 6.5 7.3 0.83 320/270 2156/1845 701/600 450/377 700/600 230/60/3 1 2 13 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 672 800 230/60/3 2 2 7/6 1.5 6.5 7.3 0.83 278/235 1756/1556 571/506 397/334 600/500 380/60/3 1 2 13 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 400 500 380/60/3 2 2 7/6 1.5 3.5 3.7 0.83 168/142 1060/973 345/316 237/199 400/300 460/60/3 1 2 13 1.5 3 3.7 0.83 139/118 878/774 285/252 334 450 460/60/3 2 2 7/6 1.5 3 3.7 0.83 139/118 878/774 285/252 197/166 300/250 575/60/3 1 2 13 1.5 2.5 3.0 0.83 111/94 705/631 229/205 268 350 575/60/3 2 2 7/6 1.5 2.5 3.0 0.83 111/94 705/631 229/205 158/133 250/225 200/60/3 1 2 14 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 817 1000 200/60/3 2 2 7/7 1.5 6.5 7.3 0.83 320/320 2156/2156 701/701 450/446 700/700 230/60/3 1 2 14 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 722 800 230/60/3 2 2 7/7 1.5 6.5 7.3 0.83 278/278 1756/1756 571/571 397/394 600/600 380/60/3 1 2 14 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 430 500 380/60/3 2 2 7/7 1.5 3.5 3.7 0.83 168/168 1060/1060 345/345 237/235 400/400 460/60/3 1 2 14 1.5 3 3.7 0.83 139/139 878/878 285/285 358 450 460/60/3 2 2 7/7 1.5 3 3.7 0.83 139/139 878/878 285/285 197/195 300/300 575/60/3 1 2 14 1.5 2.5 3.0 0.83 111/111 705/705 229/229 287 350 575/60/3 2 2 7/7 1.5 2.5 3.0 0.83 111/111 705/705 229/229 158/157 250/250 200/60/3 1 2 14 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 899 1200 200/60/3 2 2 8/6 1.5 6.5 7.3 0.83 386/320 2525/2156 821/701 539/440 800/700 230/60/3 1 2 14 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 794 1000 230/60/3 2 2 8/6 1.5 6.5 7.3 0.83 336/278 2126/1756 691/571 476/387 800/600 380/60/3 1 2 14 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 473 600 380/60/3 2 2 8/6 1.5 3.5 3.7 0.83 203/168 1306/1060 424/345 284/231 450/350 460/60/3 1 2 14 1.5 3 3.7 0.83 168/139 1065/878 346/285 394 500 460/60/3 2 2 8/6 1.5 3 3.7 0.83 168/139 1065/878 346/285 237/192 400/300 575/60/3 1 2 14 1.5 2.5 3.0 0.83 134/111 853/705 277/229 316 450 575/60/3 2 2 8/6 1.5 2.5 3.0 0.83 134/111 853/705 277/229 189/154 300/400 RLC-PRC006M-EN 43 Electrical Data Table 17. Extra efficiency — high and wide ambient Unit Size 200 250 275 300 44 # # Fan Rated # Power Ckt1/ Fan Fan VFD Cntrl Voltage1 Conn2 Comp Ckt2 kW FLA Input kVA3 RLA4 Ckt1/Ckt2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 200/60/3 1 2 16 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 978 1200 200/60/3 2 2 8/8 1.5 6.5 7.3 0.83 386/386 2525/2525 821/821 539/535 800/800 230/60/3 1 2 16 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 865 1200 230/60/3 2 2 8/8 1.5 6.5 7.3 0.83 336/336 2126/2126 691/691 476/473 800/800 380/60/3 1 2 16 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 515 700 380/60/3 2 2 8/8 1.5 3.5 3.7 0.83 203/203 1306/1306 424/424 284/282 450/450 460/60/3 1 2 16 1.5 3 3.7 0.83 168/168 1065/1065 346/346 429 500 460/60/3 2 2 8/8 1.5 3 3.7 0.83 168/168 1065/1065 346/346 237/235 400/400 575/60/3 1 2 16 1.5 2.5 3.0 0.83 134/134 853/853 277/277 344 450 575/60/3 2 2 8/8 1.5 2.5 3.0 0.83 134/134 853/853 277/277 189/188 300/300 200/60/3 1 200/60/3 2 3 12/6 1.5 6.5 7.3 1.2 270-270/386 1845-1845/2525 600-600/821 691/526 800/800 230/60/3 1 230/60/3 2 506-506/691 612/463 700/700 380/60/3 1 380/60/3 2 3 12/6 1.5 3.5 3.7 1.2 142-142/203 973-973/1306 316-316/424 364/277 450/450 460/60/3 1 3 18 1.5 3 3.7 1.2 118-118/168 774-774/1065 252-252/346 507 600 460/60/3 2 3 12/6 1.5 3 3.7 1.2 118-118/168 774-774/1065 252-252/346 305/231 350/350 575/60/3 1 3 18 1.5 2.5 3.0 1.2 94-94/134 631-631/853 205-205/277 407 500 575/60/3 2 3 12/6 1.5 2.5 3.0 1.2 94-94/134 631-631/853 205-205/277 244/184 300/300 200/60/3 1 200/60/3 2 3 14/6 1.5 6.5 7.3 1.2 320-320/386 701-701/821 817/526 1000/800 230/60/3 1 230/60/3 2 571-571/691 722/463 800/700 380/60/3 1 380/60/3 2 3 14/6 1.5 3.5 3.7 1.2 168-168/203 1060-1060/1306 345-345/424 430/277 500/450 460/60/3 1 3 20 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 555 700 460/60/3 2 3 14/6 1.5 3 3.7 1.2 139-139/168 878-878/1065 285-285/346 358/231 450/350 575/60/3 1 3 20 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 446 500 575/60/3 2 3 14/6 1.5 2.5 3.0 1.2 111-111/134 705-705/853 229-229/277 287/184 350/300 200/60/3 1 1.2 270-270/ 270-270 1845-1845/ 1845-1845 600-600/ 600-600 691/691 800/800 1556-1556/ 1556-1556 506-506/ 506-506 612/612 800/800 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 n/a n/a 3 12/6 1.5 6.5 7.3 1.2 235-235/336 1556-1556/2126 n/a n/a 2156-2156/2525 n/a 3 14/6 1.5 6.5 7.3 1.2 278-278/336 1756-1756/2126 n/a n/a 4 12/12 1.5 6.5 7.3 n/a 4 12/12 1.5 6.5 7.3 1.2 235-235/ 235-235 973-973/ 973-973 316-316/ 316-316 364/364 500/500 n/a 380/60/3 2 4 12/12 1.5 3.5 3.7 1.2 142-142/ 142-142 460/60/3 1 4 24 1.5 3 3.7 1.2 118-118/ 118-118 774-774/ 774-774 252-252/ 252-252 580 600 774-774/ 774-774 252-252/ 252-252 305/305 400/400 460/60/3 2 4 12/12 1.5 3 3.7 1.2 118-118/ 118-118 575/60/3 1 4 24 1.5 2.5 3.0 1.2 94-94/ 94-94 631-631/ 631-631 205-205/ 205-205 464 500 575/60/3 2 4 12/12 1.5 2.5 3.0 1.2 94-94/ 94-94 631-631/ 631-631 205-205/ 205-205 244/244 300/300 RLC-PRC006M-EN Electrical Data Table 17. Extra efficiency — high and wide ambient Unit Size # # Fan Rated # Power Ckt1/ Fan Fan VFD Cntrl Voltage1 Conn2 Comp Ckt2 kW FLA Input kVA3 200/60/3 350 1 200/60/3 2 230/60/3 1 230/60/3 2 380/60/3 1 380/60/3 RLA4 Ckt1/Ckt2 2 XLRA5 Ckt1/Ckt2 YLRA5 Ckt1/Ckt2 MCA6 Ckt1/ Ckt2 MOP7 Ckt1/ Ckt2 n/a 4 14/14 1.5 6.5 7.3 1.59 320-320/ 320-320 2156-2156/ 2156-2156 701-701/ 701-701 817/817 1000/1000 1.59 278-278/ 278-278 1756-1756/ 1756-1756 571-571/ 571-571 722/722 1000/1000 1.59 168-168/ 168-168 1060-1060/ 1060-1060 345-345/ 345-345 430/430 500/500 878-878/ 878-878 285-285/ 285-285 681 700 n/a 4 14/14 1.5 6.5 7.3 n/a 4 14/14 1.5 3.5 3.7 460/60/3 1 4 28 1.5 3 3.7 1.59 139-139/ 139-139 460/60/3 2 4 14/14 1.5 3 3.7 1.59 139-139/ 139-139 878-878/ 878-878 285-285/ 285-285 358/358 450/450 575/60/3 1 4 28 1.5 2.5 3.0 1.59 111-111/ 111-111 705-705/ 705-705 229-229/ 229-229 547 600 575/60/3 2 4 14/14 1.5 2.5 3.0 1.59 111-111/ 111-111 705-705/ 705-705 229-229/ 229-229 287/287 350/350 Notes: 1. Voltage Utilization Range: +/- 10% of rated voltage. Rated voltage (use range): 200/60/3 (180-220), 230/60/3 (208-254), 380/60/3 (342-418), 460/60/ 3 (414-506), 575/60/3 (516-633) 2. As standard, 140-250 ton units have a single point power connection. Optional dual point power connections are available. As standard, 275-500 ton units have dual point power connections. Optional single point power connections are available on 460V and 575V/60 Hz units. 3. Control VA includes operational controls only. It does not include evaporator heaters. A separate 115/60/1, 20 amp customer provided power connection is required to power the evaporator heaters (1640 watts). 4. RLA - Rated Load Amps 5. XLRA - Locked Rotor Amps - based on full winding (x-line) start units). YLRA for wye-delta starters is ~1/3 of LRA of x-line units. 6. MCA - Minimum Circuit Ampacity - 125 percent of largest compressor RLA plus 100 percent of all other loads. 7. Max fuse or MOPD = 225 percent of the largest compressor RLA plus 100 percent of the second compressor RLA, plus the sum of the condenser fan FLA. (Use FLA per circuit, NOT FLA for the entire unit). 8. Local codes may take precedence. 9. All ambient means standard, low, high and wide ambient options. RLC-PRC006M-EN 45 Electrical Data Table 18. Customer wire selection — standard efficiency Single point power Unit Size Circuit Breaker Dual point power - Ckt 1 Term Disc Circuit Breaker (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM Term Disc 200 (2) 4 AWG 500 MCM (3) 3/0 - 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 575 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG - 5 00 MCM 3/0350MCM 3/0500MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 200 (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 575 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 00 MCM 3/0350MCM 3/0500MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM (3) 3/0 - 500 (2) 4 AWG MCM 500 MCM 155 170 46 Disc Volt 140 Term Dual point power - Ckt 2 Circuit Breaker RLC-PRC006M-EN Electrical Data Table 18. Customer wire selection — standard efficiency (continued) Single point power Unit Size Dual point power - Ckt 1 Volt Term Disc 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG (1) 1 AWG 600 MCM or 600 MCM or (2) 1 AWG - (2) 1 AWG - 250 MCM 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 00 MCM (2) 2/0 500 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 00 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM Term 185 200 225 250 Dual point power - Ckt 2 Circuit Breaker RLC-PRC006M-EN Disc Circuit Breaker Term Disc Circuit Breaker 47 Electrical Data Table 18. Customer wire selection — standard efficiency (continued) Single point power Unit Size Volt Term Disc Term Disc Circuit Breaker Dual point power - Ckt 2 Term Disc Circuit Breaker n/a (4) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 300 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 350 48 Dual point power - Ckt 1 200 275 400 Circuit Breaker 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 00 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (3) 3/0 00 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 00 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM RLC-PRC006M-EN Electrical Data Table 18. Customer wire selection — standard efficiency (continued) Single point power Unit Size 450 500 1. 2. 3. 4. Volt Term Disc Circuit Breaker Dual point power - Ckt 1 Term Disc Circuit Breaker Dual point power - Ckt 2 Term Disc Circuit Breaker 200 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 200 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 380 n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 460 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM Non-fused unit disconnect and circuit breaker are optional. Copper wire only, based on nameplate minimum circuit ampacity (MCA). Circuit breaker sizes are for factory mounted only. n/a - not available RLC-PRC006M-EN 49 Electrical Data Table 19. Customer wire selection — high efficiency Single point power Unit Size Volt Ambient Disc Dual point power - Ckt 1 Term Disc Term Disc Circuit Breaker All (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 230 All (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 Std, Low 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 460 High, Wide 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 575 All 4 AWG 500 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 200 All (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 230 All (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 Std, Low 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 460 High, Wide 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 575 All 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 200 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 00 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM (1) 1 AWG (1) 1 AWG 600 MCM or 600 MCM or (2) 1 AWG - 250 (2) 1 AWG 250 MCM MCM 170 50 Dual point power - Ckt 2 Circuit Breaker 200 140 155 Term Circuit Breaker RLC-PRC006M-EN Electrical Data Table 19. Customer wire selection — high efficiency (continued) Single point power Unit Size Volt Ambient Term Disc Circuit Breaker Dual point power - Ckt 1 Term Dual point power - Ckt 2 Disc Circuit Breaker Term Disc Circuit Breaker 200 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 460 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 200 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 All (2) 4 AWG 500 MCM (3) 3/0350MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG - 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 All (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 All (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 Std, Low (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 00 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 High, Wide (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 All (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 185 200 225 250 RLC-PRC006M-EN 51 Electrical Data Table 19. Customer wire selection — high efficiency (continued) Single point power Unit Size Volt Ambient Term Disc Circuit Breaker Dual point power - Ckt 1 Term Disc Circuit Breaker Dual point power - Ckt 2 Term Disc Circuit Breaker 200 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 Std, Low n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 High, Wide n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 575 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 All n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 All n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 4 AWG 500 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM (1) 1 AWG 600 MCM or (2) 1 AWG 250 MCM 200 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230 All n/a (4) 4 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 - 500 MCM 380 Std, Low n/a (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 High, Wide n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 460 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575 All n/a (4) 2 AWG - (2) 4 AWG 600 MCM 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 275 300 350 400 1. 2. 3. 4. 52 Non-fused unit disconnect and circuit breaker are optional. Copper wire only, based on nameplate minimum circuit ampacity (MCA). Circuit breaker sizes are for factory mounted only. n/a - not available RLC-PRC006M-EN Electrical Data Table 20. Customer wire selection — extra efficiency Single point power Unit Size Dual point power - Ckt 1 Dual point power - Ckt 2 Volt Term Disc Circuit Breaker 200 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG - 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 460 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 575 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 200 (2) 4 AWG 500 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 460 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 575 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 - 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 4 AWG 500 MCM 3/0350MCM 3/0350MCM 140 Term 155 170 RLC-PRC006M-EN Disc Circuit Breaker Term Disc Circuit Breaker 53 Electrical Data Table 20. Customer wire selection — extra efficiency (continued) Single point power Unit Size Dual point power - Ckt 1 Volt Term Disc 200 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230 (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 380 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 460 (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM 3/0350MCM 3/0500MCM 200A (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230A (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380A (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 4 AWG - 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460A (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575A (2) 4 AWG 500 MCM (2) 2/0 - 5 00 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM Term 185 200 Disc Circuit Breaker Term Disc Circuit Breaker 200A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380A n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 250 200A n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 230A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380A n/a (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 275 54 Dual point power - Ckt 2 Circuit Breaker 460A n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM RLC-PRC006M-EN Electrical Data Table 20. Customer wire selection — extra efficiency (continued) Single point power Unit Size Volt Term Disc 1. 2. 3. 4. Dual point power - Ckt 1 Term Disc Circuit Breaker Dual point power - Ckt 2 Term Disc Circuit Breaker 200A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 - 500 MCM 230A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380A n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 - 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 460A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 575A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 300 350 Circuit Breaker 200A n/a (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM (4) 2 AWG 600 MCM (4) 3/0 500 MCM (4) 3/0 500 MCM 230A n/a (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM (2) 4 AWG 500 MCM (3) 3/0 500 MCM (3) 3/0 500 MCM 380A n/a (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 - 500 MCM 460A n/a (4) 2 AWG 600 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM (2) 4 AWG 500 MCM (2) 2/0 500 MCM (2) 2/0 500 MCM 575A n/a (4) 2 AWG 600 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM 4 AWG 500 MCM (1) #1 600 MCM or (2) #1 250 MCM (1) #1 600 MCM or (2) #1 250 MCM Non-fused unit disconnect and circuit breaker are optional. Copper wire only, based on nameplate minimum circuit ampacity (MCA). Circuit breaker sizes are for factory mounted only. n/a - not available RLC-PRC006M-EN 55 Release on 4/25/2 Electrical Connection 56 RLC-PRC006M-EN Electrical Connection RLC-PRC006M-EN 57 Electrical Connection 58 RLC-PRC006M-EN Electrical Connection RLC-PRC006M-EN 59 Release on 5 Electrical Connection 60 RLC-PRC006M-EN Electrical Connection RLC-PRC006M-EN 61 Electrical Connection 62 RLC-PRC006M-EN Electrical Connection RLC-PRC006M-EN 63 Dimensions Note: Mounting location dimensions may vary on units with seismic rating. See unit submittals.. 64 RLC-PRC006M-EN Dimensions RLC-PRC006M-EN 65 140 XE - 60 HZ 5/8 Dimensions 66 RLC-PRC006M-EN 155, 170 XE - 60 HZ , & 155 XE Dimensions RLC-PRC006M-EN 67 185 & 200 XE - 60 HZ & 185 13 13 Dimensions 68 RLC-PRC006M-EN Dimensions RLC-PRC006M-EN 69 ON 275, 300 & 250 250 XE - 60 HZ Dimensions 70 RLC-PRC006M-EN 275 XE - 60 HZ Dimensions RLC-PRC006M-EN 71 300 XE - 60HZ Dimensions 72 RLC-PRC006M-EN 350 XE - 60 HZ Dimensions RLC-PRC006M-EN 73 Weights Non-Seismically Rated Units Table 21. Weight - packaged units - 60 Hz - aluminum or CompleteCoat coils Standard Efficiency High Efficiency Extra Efficiency Unit Size (tons) lb kg lb kg lb kg lb kg lb kg lb kg 140 10832 4913 11146 5056 10859 4926 11160 5062 12171 5521 12585 5708 155 10910 4949 11146 5056 12114 5495 12445 5645 13984 6343 14293 6483 170 10877 4934 11218 5088 12171 5521 12585 5708 14454 6556 14721 6677 185 12479 5660 12899 5851 13984 6343 14293 6483 15915 7219 16413 7445 200 12884 5844 13193 5984 14454 6556 14721 6677 16016 7265 16413 7445 225 14635 6638 14966 6788 15915 7219 16413 7445 250 14916 6766 15191 6890 16016 7265 16413 7445 20476 9288 21048 9547 275 19025 8630 19685 8929 20393 9250 21048 9547 21667 9828 22160 10052 300 20699 9389 21214 9622 21667 9828 22160 10052 24073 10919 24700 11204 350 21550 9775 22005 9981 24073 10919 24700 11204 27136 12309 27750 12587 400 25409 11525 25854 11727 27136 12309 27750 12587 450 26816 12163 27393 12425 n/a n/a 500 27136 12309 27912 12661 n/a n/a Shipping Operating Shipping Operating Shipping Operating n/a n/a 1. Operating weight includes refrigerant and water. 2. Shipping weight includes refrigerant. 3. All weights +/- 3%. Table 22. Weight - packaged units - 60 Hz - copper coils Standard Efficiency High Efficiency Extra Efficiency Unit Size (tons) lb kg lb kg lb kg lb kg lb kg lb kg 140 13407 6081 13734 6230 13426 6090 13734 6230 15590 7071 15998 7257 155 13420 6087 13734 6230 15647 7097 15854 7191 18250 8278 18613 8443 170 13442 6097 13733 6229 15590 7071 15998 7257 18701 8483 18958 8599 185 15870 7198 16253 7372 18250 8278 18613 8443 20794 9432 21290 9657 200 16304 7395 16630 7543 18701 8483 18958 8599 20881 9471 21290 9657 225 18739 8500 18156 8235 20794 9432 21290 9657 250 18905 8575 19223 8719 20881 9471 21290 9657 26017 11801 26558 12046 275 23905 10843 24608 11162 26017 11801 26558 12046 27660 12546 28182 12783 300 26039 11811 26580 12056 27660 12546 28182 12783 30848 13992 31431 14257 350 27395 12426 27920 12664 30848 13992 31431 14257 35166 15951 35688 16188 400 32216 14613 32723 14843 35014 15882 35688 16188 450 32682 14824 33178 15049 n/a n/a 500 35014 15882 35787 16233 n/a n/a Shipping Operating Shipping Operating Shipping Operating n/a n/a 1. Operating weight includes refrigerant and water. 2. Shipping weight includes refrigerant. 3. All weights +/- 3%. 74 RLC-PRC006M-EN Weights Seismically Rated Units Table 23. Weight - seismically rated - packaged units - 60 Hz - aluminum or CompleteCoat coils Standard Efficiency High Efficiency Extra Efficiency Unit Size (tons) lb kg lb kg lb kg lb kg lb kg lb kg 140 11374 5159 11646 5283 11402 5172 11711 5312 12780 5797 13185 5981 155 11456 5196 11703 5308 12720 5770 13067 5927 14683 6660 15021 6813 170 11421 5180 11779 5343 12780 5797 13214 5994 15177 6884 15433 7000 185 13103 5943 13544 6143 14683 6660 15008 6807 16711 7580 17234 7817 200 13528 6136 13853 6284 15177 6884 15457 7011 16817 7628 17234 7817 225 15367 6970 15714 7128 16711 7580 17234 7817 250 15662 7104 15951 7235 16817 7628 17234 7817 21500 9752 22100 10025 275 19976 9061 20669 9375 21413 9713 22100 10025 22750 10319 23268 10554 300 21734 9858 22275 10104 22750 10319 23268 10554 25277 11465 25935 11764 350 22628 10264 23105 10480 25277 11465 25935 11764 28493 12924 29138 13216 400 26679 12102 27147 12313 28493 12924 29138 13216 450 28157 12772 28763 13046 n/a n/a 500 28493 12924 29308 13294 n/a n/a Shipping Operating Shipping Operating Shipping Operating n/a n/a 1. Operating weight includes refrigerant and water. 2. Shipping weight includes refrigerant. 3. All weights +/- 3%. RLC-PRC006M-EN 75 Mechanical Specifications General Units are leak and pressure tested at 390 psig high side, 250 psig low side, then evacuated and charged. All Air-Cooled Series R Chillers are factory tested prior to shipment. Packaged units ship with a full operating charge of oil and refrigerant. Unit panels, structural elements and control boxes are constructed of galvanized steel and mounted on a welded structural steel base. Unit panels and control boxes are finished with a baked on powder paint, and the structural base with an air dry paint. All paint meets the requirement for outdoor equipment of the US Navy and other federal government agencies. Evaporator The evaporator is a tube-in-shell heat exchanger design with internally and externally finned copper tubes roller expanded into the tube sheet.The evaporator is designed, tested and stamped in accordance with ASME for a refrigerant side working pressure of 200 psig.The evaporator is designed for a water side working pressure of 150 psig. Water connections are grooved pipe. Each shell includes a vent, a drain and fittings for temperature control sensors and is insulated with 3/4 inch equal insulation (K=0.28). Evaporator heaters with thermostat are provided to help protect the evaporator from freezing at ambient temperatures down to -20°F (-29°C). Factory installed flow switch is installed on a pipe stub in the evaporator inlet. Condenser and Fans Air-cooled condenser coils have aluminum fins mechanically bonded to internally finned seamless copper tubing.The condenser coil has an integral subcooling circuit. Condensers are factory proof and leak tested at 506 psig. Direct drive vertical discharge condenser fans are dynamically balanced.Totally enclosed air over motors completely seal the motor windings to prevent exposure to ambient conditions.Three-phase condenser fan motors with permanently lubricated ball bearings and internal thermal overload protection are provided. Standard units will start and operate between 25 to 115°F (-4 to 46°C) ambient. Compressor and Lube Oil System The rotary screw compressor is semi-hermetic, direct drive, 3600 rpm, 60 Hz, with capacity control slide valve, a load/unload valve, rolling element bearings, differential refrigerant pressure oil pump and oil heater.The motor is a suction gas cooled, hermetically sealed, two-pole squirrel cage induction motor. Oil separator and filtration devices are provided separate from the compressor. Check valves in the compressor discharge and lube oil system and a solenoid valve in the lube system are also provided. Refrigeration Circuits Each unit has two refrigerant circuits, with one or two rotary screw compressors per circuit. Each refrigerant circuit includes a compressor suction and discharge service valve, liquid line shutoff valve, removable core filter, liquid line sight glass with moisture indicator, charging port and an electronic expansion valve. Fully modulating compressors and electronic expansion valves provide variable capacity modulation over the entire operating range. Unit Controls All unit controls are housed in an outdoor rated weather tight enclosure with removable plates to allow for customer connection of power wiring and remote interlocks. All controls, including sensors, are factory mounted and tested prior to shipment. Microcomputer controls provide all control functions including startup and shut down, leaving chilled water temperature control, evaporator flow proving, compressor and electronic expansion valve modulation, fan sequencing, anti-recycle logic, automatic lead/lag compressor starting and load limiting.The unit control module, utilizing Adaptive Control™ microprocessor, automatically takes action to avoid unit shutdown due to abnormal operating conditions associated with low refrigerant pressure, high condensing pressure and motor current overload. Should the abnormal operating condition continue until a protective limit is violated, the unit will be shut down. Unit protective functions 76 RLC-PRC006M-EN Options include loss of chilled water flow, evaporator freezing, loss of refrigerant, low refrigerant pressure, high refrigerant pressure, reverse rotation, compressor starting and running over current, phase loss, phase imbalance, phase reversal, and loss of oil flow. A digital display indicates chilled water setpoint and leaving chilled water temperature as standard. While current limit setpoint, evaporator and condenser refrigerant pressures, and electrical information are an option. Both standard and optional displays can be viewed on the unit without opening any control panel doors. Standard power connections include main three phase power to the compressors, condenser fans and control power transformer and optional connections are available for the 115 volt/60 Hz single phase power for freeze protection on the evaporator heaters. Starters Starters are housed in a weather tight enclosure with removable cover plate to allow for customer connection of power wiring. Across-the-line starters are standard on all 380-575/60 volt units. Wye Delta closed transition starters (33 percent of LRA inrush) are optional on 380-575/60 volt units and standard on 200-230/60 Hz volt units.Typically,Trane helical rotary screw compressors are up to full speed in one second when started across-the-line and have equivalent inrush with similar size reciprocating compressor with part wind starters. Chilled Water Reset This provides the control logic and factory installed sensors to reset leaving chilled water temperature.The setpoint can be reset based on ambient temperature or return evaporator water temperature. Flow Control The factory installed flow switch is provided with the control logic and relays to turn the chilled water flow on and off as the chiller requires for operation and protection.This function is a requirement on the Air-Cooled Series R Chiller. Options Applications Options High Efficiency/Performance Option High efficiency option provides an increase in efficiency over standard efficiency by providing oversized heat exchangers for two purposes. One, it allows the unit to be more energy efficient. Two, the unit will have enhanced operation in high ambient conditions. Extra Efficiency/Performance Option Extra efficiency option provides an increase in efficiency over the high efficiency unit by providing oversized heat exchangers for two purposes. One, it allows the unit to be more energy efficient. Two, the unit will have enhanced operation in high ambient conditions. Ice Making The ice making option provides special control logic and oil coolers to handle low temperature brine applications (less than 40°F [4.4°C] leaving evaporator temperature) for thermal storage applications. Low Temperature Brine The low temperature option provides special control logic and oil coolers to handle low temperature brine applications (less than 40°F [4.4°C] leaving evaporator temperature). RLC-PRC006M-EN 77 Options Low Ambient Option The low ambient option provides special control logic, oil coolers, and variable frequency drives on the condenser fan circuits to permit low temperature startup and operation down to 0°F (-18°C). High Ambient Option The high ambient option consists of special control logic and oil coolers to permit high ambient (up to 125°F [51°C]) operation.This option offers the best performance when coupled with the high efficiency performance option. Remote Evaporator The remote evaporator option is available on the RTAC 140-250 ton units.This option provides a pre-engineered method of installing the evaporator and all related components indoors. Remote evaporator installations allow the water loop to remain indoors to prevent freezing, thus eliminating the addition of glycol to the system and the resulting performance degradation. Please contact yourTrane Sales Representative for split system design guidelines found in Engineering Bulletin RLC-PRB014-EN. Electrical Options Circuit Breaker A HACR rated molded case capacity circuit breaker (UL approved) is available.The circuit breaker can also be used to disconnect the chiller from main power with a through the door handle and comes pre-wired from the factory with terminal block power connections.The external operator handle is lockable. Non-Fused Power Disconnect Switch The non-fused molded case disconnect switch (UL approved) is used to disconnect the chiller from main power and comes pre-wired from the factory with terminal block power connections.The external operator handle is lockable. Single/Dual Incoming Power Line Connection Single or dual points of termination are available for incoming power line connections*. Units with 3-4 compressors must order circuit breakers with the single point connection option.*Some restrictions may apply. Wye-Delta Compressor Start Type This option provides a reduced inrush starter. Wye-Delta starters are standard on 200-230 volt machines. Control Options BACnet Communications Interface Allows the user to easily interface with BACnet via a single twisted pair wiring to a factory installed and tested communication board. LonTalk (LCI-C) Communications Interface Provides the LonMark chiller profile inputs/outputs for use with a generic building automation system. Remote Input Options Permits remote chilled liquid setpoint, remote current limit setpoint, or both by accepting a 4-20 mA or 2-10 Vdc analog signal. 78 RLC-PRC006M-EN Options Remote Output Options Permits alarm relay outputs, ice making outputs, or both. Tracer Summit Communication Interface Permits bi-directional communication to theTracer Summit system. Other Options Architectural Louvered Panels Louvered panels cover the complete condensing coil and service area beneath the condenser. Coil Protection Louvered panels protect the condenser coils only. Compressor Sound Enhancement Factory installed weatherproof compressor enclosure to reduce compressor sound levels. Condenser Corrosion Protection Copper fins and CompleteCoat are available on all size units for corrosion protection. Job site conditions should be matched with the appropriate condenser fin materials to inhibit coil corrosion and ensure extended equipment life.The CompleteCoat option provides fully assembled coils with a flexible dip and bake epoxy coating. Convenience Outlet Provides a 15 amp, 115 volt (60 Hz) convenience outlet on the unit. Flange Kit Provides a raised face flange kit that converts the grooved pipe evaporator water connections to flange connectors. Insulation for High Humidity The evaporator is covered with factory-installed 1.25 inch (31.8 mm) Armaflex II or equal (k=0.28) insulation. Foam insulation is used on the suction line. Low Noise Fans Complete fan assembly combining ultra quiet nine blade fans andTEAO fan motors to provide sound reductions with no performance degradation to the unit.The fan blades are heavy-duty molded plastic with wavy edges to reduce airflow turbulation. Isolators - Neoprene Isolators provide isolation between chiller and structure to help eliminate vibration transmission. Neoprene isolators are more effective and recommended over spring isolators. Elastomeric Isolation Pads - Seismically Rated Elastomeric isolation pads are designed and tested to control the motion of the chiller during a seismic event. Isolators - Seismically Rated Spring isolators are designed and tested to control the motion of the chiller during a seismic event. Seismically Rated Unit - IBC & OSHPD Unit is built and certified for seismic applications in accordance with OSHPD and the following International Building Code (IBC) releases: 2000, 2003, 2006 and 2009. RLC-PRC006M-EN 79 Options Performance Tests Performance and witness tests are available, based on requested operating points, to certify chiller performance in accordance with AHRI Standard 550/590. Rapid Restart Test After completion of a standard full load witness test, power to the chiller will be cut and then reapplied to demonstrate the chiller’s rapid restart capabilities for disaster relief. Tarp The unit will be covered at the factory with a PVC coated polyester tarp that is tied to the chiller base to help protect the chiller from debris during shipment especially in the winter months and on shipping vessels. This option may also be helpful if the chiller will be stored at the jobsite before use. 80 RLC-PRC006M-EN Trane optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, Trane offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information, visit www.Trane.com. Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice. © 2015 Trane All rights reserved RLC-PRC006M-EN 15 Jan 2015 We are committed to using environmentally Supersedes RLC-PRC006-EN (25 May 2012) conscious print practices that reduce waste.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Sheryl Hill Create Date : 2015:01:15 08:28:50Z Keywords : RTAC, air-cooled, 60 Hz Modify Date : 2015:01:16 10:41:47-07:00 Subject : Air-Cooled Series R? Chillers, Model RTAC, 140 to 500 nominal tons (60 Hz) Has XFA : No Language : en Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : FrameMaker 10.0.2 Metadata Date : 2015:01:16 10:41:47-07:00 Format : application/pdf Title : RLC-PRC006M-EN (01/2015): Product Catalog, Air-Cooled Series R® Chillers, Model RTAC, 140 to 500 nominal tons (60 Hz) Creator : Sheryl Hill Description : Air-Cooled Series R? Chillers, Model RTAC, 140 to 500 nominal tons (60 Hz) Producer : Acrobat Distiller 10.1.13 (Windows) Document ID : uuid:3e0643ac-fdb6-4b1c-a92d-239874bf83f1 Instance ID : uuid:395afb17-192b-4e4e-87e3-bda6d560433a Page Mode : UseOutlines Page Count : 82EXIF Metadata provided by EXIF.tools