Trane Tdh2B060A9V3Va Users Manual 22 1814 08 08/01/2012 Product Data Upflow/ Horizontal Left, Downflow/ Right Variable Speed Two Stage Condensing
Trane Furnace TDH2B080A9V4VA TUH2XV
TUH2C100A9V5VA to the manual 704b5e89-818b-4b9f-8be5-ce56b2833b44
2015-01-21
: Trane Trane-Tdh2B060A9V3Va-Users-Manual-236178 trane-tdh2b060a9v3va-users-manual-236178 trane pdf
Open the PDF directly: View PDF .
Page Count: 30
Download | |
Open PDF In Browser | View PDF |
Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VA TUH2B080A9V3VA TUH2B080A9V4VA TUH2C100A9V4VA TUH2C100A9V5VA TUH2D120A9V5VA TDH2B060A9V3VA TDH2B080A9V3VA TDH2B080A9V4VA TDH2C100A9V4VA TDH2D120A9V5VA Direct Vent with Variable Speed Blower Variable Speed Inducer *DH-A9V-V *UH-A9V-V DOWNFLOW UPFLOW UPFLOW/HORIZONTAL DOWNFLOW/HORIZONTAL PUB. NO. 22-1814-08 General Features NATURAL GAS MODELS Central Heating furnace designs are certified by the American Gas Association for both natural and L.P. gas. Limit setting and rating data were established and approved under standard rating conditions using American National Standards Institute standards. SAFE OPERATION The Integrated System Control has solid state devices, which continuously monitor for presence of flame, when the system is in the heating mode of operation. Dual solenoid combination gas valve and regulator provide additional safety. QUICK HEATING Durable, cycle tested, heavy gauge aluminized steel heat exchanger quickly transfers heat to provide warm conditioned air to the structure. Low energy power vent blower, to increase efficiency and provide a positive discharge of gas fumes to the outside. BURNERS Multiport Inshot burners will give years of quiet and efficient service. All models can be converted to L.P. gas without changing burners. INTEGRATED SYSTEM CONTROL Exclusively designed operational program provides total control of furnace limit sensors, blowers, gas valve, flame control and includes self diagnostics for ease of service. Also contains connection points for E.A.C./Humidifier. © 2012 Trane All Rights Reserved 2 AIR DELIVERY The variable speed blower motor has sufficient airflow for most heating and cooling requirements and will switch from heating to cooling speeds on demand from room thermostat. The blower door safety switch will prevent or terminate furnace operation when the blower door is removed. SECONDARY HEAT EXCHANGER The XV95 has a special type 294C™ stainless steel secondary heat exchanger to reclaim heat from flue gases which would normally be lost instead. STYLING Heavy gauge steel and “wraparound” cabinet construction is used in the cabinet with baked-on enamel finish for strength and beauty. The heat exchanger section of the cabinet is completely lined with foil faced fiberglass insulation. This results in quiet and efficient operation due to the excellent acoustical and insulating qualities of fiberglass. Built-in bottom pan and alternate bottom, left or right side return air connection provision. FEATURES AND GENERAL OPERATION The XV95 High Efficiency Gas Furnaces utilize an Adaptive Heat Up Silicon Nitride Hot Surface Ignition system, which eliminates the waste of a constant burning pilot. The integrated system control lights the main burners upon a demand for heat from the room thermostat. Complete front service access. a. Low energy power venter b. Vent proving pressure switch. Pub. No. 22-1814-08 Contents General Features Features and Benefits 2 4 Standard Equipment 4 Optional Equipment 5 General Data 6-8 TUH2B060A9V3VA TUH2B080A9V3VA TUH2B080A9V4VA TUH2C100A9V4VA TUH2C100A9V5VA TUH2D120A9V5VA TDH2B060A9V3VA TDH2B080A9V3VA TDH2B080A9V4VA TDH2C100A9V4VA TDH2D120A9V5VA Performance Data Venting Table Electrical Data Field Wiring Dimensions Pub. No. 22-1814-08 3 9-19 20 21-24 25-26 27-28 Features and Benefits XV 95 STANDARD EQUIPMENT • Variable Speed Blower Motor • Silicon Nitride Igniter with adaptive heat up • Variable speed induced draft blower • Direct/Non-Direct vent option • Fused 24 volt control circuit • Manual reset burner safety switches • Power supply 115/1/60 • Convertible to horizontal on left side • 2-stage gas valve • PVC venting-1 or 2 pipe option • Accessory hook-up capability • Integrated solid state control with selfdiagnostics • Attractive color accents • Heavy gauge aluminized steel heat exchanger • Multi-port In-shot burners • Quiet induced draft blower • Lite Port™ extended system diagnostics • Stored fault code history in micro processor nonvocatile memory • Cleanable high velocity filters (upflow only) • Hinged blower door * • Perfect fit door latches* • Insulated blower door* • Gasketed blower door* • Complete front service access • Left/right gas connection • Adjustable fan off times • Optional L.P conversion kit • Selectable cooling fan off delay eliminates need for BAY24X045 time delay kit * (Upflow only) 4 Pub. No. 22-1814-08 Features and Benefits XV 95 OPTIONAL EQUIPMENT Thermostat, 2-Stage Heat / 1-Stage Cooling............................................................................................................ TAYSTAT241 [ Thermostat, Media Programmable 2-Stage Heating...............................................................................................TAYSTAT302C [ Thermostat, Mechanical Heating Only With Fan Switch..........................................................................................TAYSTAT303C [ Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ...............................................................................AY28X092 [ Thermostat, Heating/Cooling Single Stage (Mounts Vertically).................................................................................BAYSTAT305 [ Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling....................................................................TAYSTAT300C [ Propane Conversion Kit......................................................................................................................................... BAYLPKT210A [ Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace)............................................................ TFM145A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)............................................................ TFM175A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace).................................................................. TFM210A9FR0 [ Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)............................................................ TFM245A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace).....................................................TFP145A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace).....................................................TFP175A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace)............................................................TFP210A9FR0 [ Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace).....................................................TFP245A9FR0 [ Coil Enclosure (14-1/2" Wide Cabinets).......................................................................................................... BAYCLE14A1422A [ Coil Enclosure (17-1/2" Wide Cabinets) ........................................................................................................ BAYCLE17A1722A [ Coil Enclosure (21" Wide Cabinets) ............................................................................................................... BAYCLE21A2130A [ Coil Enclosure (24-1/2" Wide Cabinets) ........................................................................................................ BAYCLE24A2430A [ Downflow Subbase.................................................................................................................................................. BAYBASE205 [ Side Filter Rack........................................................................................................................................................ BAYFLTR200 [ Filter Kit/Horizontal Conversion TUH2-060,080........................................................................................................ BAYFLTR203 [ Filter Kit/Horizontal Conversion TUH2-100............................................................................................................... BAYFLTR204 [ Filter Kit/Horizontal Conversion TUH2-120............................................................................................................... BAYFLTR205 [ High Altitude Pressure Switch Kit TUH2-060 ............................................................................................. BAYSWT10AHALTA1 [ High Altitude Pressure Switch Kit TUH2-080,100,120 ............................................................................... BAYSWT08AHALTA1 [ Concentric Vent Kit TUH2 Furnaces................................................................................................................BAYAIR30AVENTA [ Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces.............................................................................BAYVENT200B [ Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces.........................................................................BAYMFGH100A [ Cleanable Filter (14.5"/17.5" wide Upflow models)................................................................................................... BAYFLTR317 [ Cleanable Filter (21" wide Upflow models)............................................................................................................... BAYFLTR321 [ Cleanable Filter (24.5" wide Upflow models)............................................................................................................ BAYFLTR324 [ CleanEffects™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace)............................................ TFD145ALFR000B [ CleanEffects™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ............................................TFD175ALFR000B [ CleanEffects™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) ...................................................TFD210ALFR000B [ CleanEffects™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ............................................TFD245ALFR000B [ CleanEffects™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) ....................................... TFD14DALFR000B [ CleanEffects™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) ....................................... TFD17DALFR000B [ CleanEffects™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) ............................................. TFD21DALFR000B [ CleanEffects™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) ....................................... TFD24DALFR000B [ CleanEffects™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners)...................................... BAYTRANS12024 [ 1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide. Pub. No. 22-1814-08 5 ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] ] General Data TUH2 PRODUCT SPECIFICATIONS1 Product Specifications 1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUH2B060A9V3VA Upflow / Horizontal TUH2B080A9V3VA Upflow / Horizontal TUH2B080A9V4VA Upflow / Horizontal TUH2C100A9V4VA Upflow / Horizontal 39,000 37,830 60,000 58,200 97 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 17x25 - 1 in. 2 Round 52,000 50,440 80,000 77,600 97 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 17x25 - 1 in. 2 Round 52,000 50,440 80,000 77,600 97 35 - 65 DIRECT 11 x 8 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 17x25 - 1 in. 2 Round 65,000 62,855 100,000 96,700 96.7 35 - 65 DIRECT 10 x 10 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 20x25 - 1 in. 3 Round Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I 20 20 20 20 3 — 45 3 — 56 Redundant - Two Stage 4 — 45 4 — 56 Redundant - Two Stage 4 — 45 4 — 56 Redundant - Two Stage 5 — 45 5 — 56 Redundant - Two Stage Hot Surface Igniter Multiport Inshot 3 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 4 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 4 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 5 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 23 x 30-1/2 158 / 146 168 / 156 170 / 158 197 / 185 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. 6 Pub. No. 22-1814-08 General Data TUH2/TDH2 PRODUCT SPECIFICATIONS1 PRODUCT SPECIFICATIONS 1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TUH2C100A9V5VA Upflow / Horizontal TUH2D120A9V5VA Upflow / Horizontal TDH2B060A9V3VA Downflow / Horizontal TDH2B080A9V3VA Downflow / Horizontal 65,000 62,855 100,000 96,700 96.7 35 - 65 DIRECT 11 x 10 1 Variable See Fan Performance Table 1 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 20x25 - 1 in. 3 Round 78,000 75,426 120,000 116,040 96.7 40 - 70 DIRECT 10 x 10 1 Variable See Fan Performance Table 1 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 1 - 24x25 - 1 in. 3 Round 39,000 37,000 60,000 57,000 95 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 14x20 - 1 in. 2 Round 52,000 49,400 80,000 76,000 95 35 - 65 DIRECT 10 x 8 1 Variable See Fan Performance Table 1/2 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 14x20 - 1 in. 2 Round Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I 20 20 20 20 5 — 45 5 — 56 Redundant - Two Stage 6 — 45 6 — 56 Redundant - Two Stage 3 — 45 3 — 56 Redundant - Two Stage 4 — 45 4 — 56 Redundant - Two Stage Hot Surface Igniter Multiport Inshot 5 115/1/60 16.3 20 1/2 HxWxD 41-3/4 x 23 x 30-1/2 Hot Surface Igniter Multiport Inshot 6 115/1/60 15.2 20 1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 3 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 4 115/1/60 11.1 15 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 199 / 187 206 / 193 160/ 146 168 / 158 1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3 2 For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level. 3 Based on U.S. government standard tests. 4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes. Pub. No. 22-1814-08 7 General Data TDH2 PRODUCT SPECIFICATIONS1 PRODUCT SPECIFICATIONS 1 MODEL TYPE RATINGS 2 1st Stage Input BTUH 1st Stage Capacity BTUH (ICS) 3 2nd Stage Input BTUH 2nd Stage Capacity BTUH (ICS) 3 AFUE Temp. rise (Min.-Max.) °F. BLOWER DRIVE Diameter - Width (In.) No. Used Speeds (No.) CFM vs. in. w.g. Motor HP R.P.M. Volts / Ph / Hz COMBUSTION FAN - Type Drive - No. Speeds Motor HP - RPM Volts / Ph / Hz FLA FILTER — Furnished? Type Recommended Hi Vel. (No.-Size-Thk.) VENT — Size (in.) HEAT EXCHANGER Type -Fired -Unfired Gauge (Fired) ORIFICES — Main Nat. Gas. Qty. — Drill Size L.P. Gas Qty. — Drill Size GAS VALVE PILOT SAFETY DEVICE Type BURNERS — Type Number POWER CONN. — V / Ph / Hz 4 Ampacity (In Amps) Max. Overcurrent Protection (Amps) PIPE CONN. SIZE (IN.) DIMENSIONS Crated (In.) WEIGHT Shipping (Lbs.) / Net (Lbs) TDH2B080A9V4VA Downflow / Horizontal TDH2C100A9V4VA Downflow / Horizontal TDH2D120A9V5VA Downflow / Horizontal 52,000 49,400 80,000 76,000 95 35 - 65 DIRECT 11 x 8 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 14x20 - 1 in. 2 Round 65,000 61,750 100,000 95,000 95 35 - 65 DIRECT 10 x 10 1 Variable See Fan Performance Table 3/4 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 16x20 - 1 in. 3 Round 78,000 74,000 120,000 114,000 95 40 - 70 DIRECT 10 x 10 1 Variable See Fan Performance Table 1 Variable 115/1/60 Centrifugal Direct - Variable 1/50 - 5000 33 - 110/3/60 - 180 1.0 Yes High Velocity 2 - 16x20 - 1 in. 3 Round Aluminized Steel - Type I Aluminized Steel - Type I Aluminized Steel - Type I 20 20 20 4 — 45 4 — 56 Redundant - Two Stage 5 — 45 5 — 56 Redundant - Two Stage 6 — 45 6 — 56 Redundant - Two Stage Hot Surface Igniter Multiport Inshot 4 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 19-1/2 x 30-1/2 Hot Surface Igniter Multiport Inshot 5 115/1/60 13.5 20 1/2 HxWxD 41-3/4 x 23 x 30-1/2 Hot Surface Igniter Multiport Inshot 6 115/1/60 15.2 20 1/2 HxWxD 41-3/4 x 26-1/2 x 30-1/2 172 / 160 185 / 175 206 / 196 8 Pub. No. 22-1814-08 *UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 1st Stage Capacity = 37,830 2nd Stage Capacity = 58,200 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 600 600 600 600 57 57 57 57 85 110 155 190 0.9 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 700 49 90 700 49 130 700 49 175 700 49 210 - NORMAL ** ON OFF CFM TEMP. RISE WATTS 775 44 105 775 44 155 775 44 195 775 44 240 - HIGH OFF OFF CFM TEMP. RISE WATTS 870 39 135 870 39 185 870 39 235 870 39 290 - LOW ON ON CFM TEMP. RISE WATTS 860 61 140 920 57 200 920 57 245 920 57 300 670 79 245 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1000 53 190 1000 53 255 1000 53 305 1000 53 340 700 75 255 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1125 47 250 1125 47 315 1125 47 370 1025 51 355 775 68 285 HIGH OFF OFF CFM TEMP. RISE WATTS 1250 42 340 1250 42 405 1250 42 445 1100 48 390 1000 53 355 - NOTES: * First letter may be "A" or "T" ** Factory setting *UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 1.5 2.0 2.5 3 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 575 65 575 90 575 125 550 155 - NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 640 70 640 110 640 140 630 175 - HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 700 85 700 125 700 160 700 200 - LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 700 100 700 130 700 170 700 210 - NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 800 115 800 155 800 200 800 250 - HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 900 140 900 195 900 240 900 290 - LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 875 130 875 180 875 230 875 270 - NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1000 175 1000 235 1000 285 1000 335 900 310 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1125 235 1125 295 1125 345 1100 370 925 318 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1050 195 1050 260 1050 305 1050 350 920 315 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1200 275 1200 330 1200 385 1100 385 940 330 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1325 360 1325 425 1300 460 1175 425 1000 365 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 22-1814-08 9 *UH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON NORMAL ** ON OFF HIGH OFF OFF CFM TEMP. RISE WATTS 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 800 800 800 800 56 56 56 56 105 140 180 220 0.9 800 56 265 CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 860 52 115 880 51 165 890 50 215 920 48 265 910 49 320 960 46 150 990 45 200 1000 44 230 1020 44 310 1010 44 350 CFM TEMP. RISE WATTS 1080 41 195 1110 40 255 1120 40 315 1120 40 365 1080 41 390 CFM TEMP. RISE WATTS 1100 62 205 1100 62 260 1120 61 320 1120 61 370 1090 63 400 CFM TEMP. RISE WATTS 1210 57 265 1240 55 340 1260 54 410 1260 54 470 1130 61 430 CFM TEMP. RISE WATTS 1360 50 365 1390 49 445 1400 49 500 1360 50 535 1210 57 475 CFM TEMP. RISE WATTS 1360 50 355 1390 49 450 1400 49 520 1350 51 535 1180 58 465 NOTES: * First letter may be "A" or "T" ** Factory setting *UH2B080A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.0 2.5 3.0 3.5 AIRFLOW SETTING LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 0.1 0.3 0.5 0.7 0.9 750 84 840 109 940 136 850 113 960 150 1080 195 1020 175 1170 240 1290 310 1170 250 1360 365 1360 355 750 122 840 146 940 177 850 150 990 200 1110 255 1020 225 1180 300 1320 410 1190 315 1390 445 1390 450 750 154 840 181 940 215 870 200 1000 230 1120 315 1040 280 1200 365 1350 470 1210 370 1400 500 1400 520 720 185 840 226 940 274 890 250 1020 305 1120 365 1050 330 1200 415 1340 520 1210 435 1360 535 1350 535 710 221 820 264 940 318 890 295 1010 350 1080 390 1050 375 1130 420 1150 440 1100 405 1210 475 1180 460 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 10 Pub. No. 22-1814-08 *UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 1st Stage Capacity = 50,440 2nd Stage Capacity = 77,600 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 800 800 800 800 56 56 56 56 105 140 180 220 0.9 800 56 265 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 860 52 115 880 51 165 890 50 215 920 48 265 910 49 320 NORMAL ** ON OFF CFM TEMP. RISE WATTS 960 46 150 990 45 200 1000 44 230 1020 44 310 1010 44 350 HIGH OFF OFF CFM TEMP. RISE WATTS 1080 41 195 1110 40 255 1120 40 315 1120 40 365 1080 41 390 LOW ON ON CFM TEMP. RISE WATTS 1100 62 205 1100 62 260 1120 61 320 1120 61 370 1090 63 400 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1210 57 265 1240 55 340 1260 54 410 1260 54 470 1130 61 430 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1360 50 365 1390 49 445 1400 49 500 1360 50 535 1210 57 475 HIGH OFF OFF CFM TEMP. RISE WATTS 1360 50 355 1390 49 450 1400 49 520 1350 51 535 1180 58 465 NOTES: * First letter may be "A" or "T" ** Factory setting *UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4.0 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 857 107 849 143 841 179 833 223 825 266 OFF OFF CFM WATTS 970 158 971 205 973 251 966 298 960 345 ON ON OFF CFM WATTS 1082 209 1093 266 1104 323 1099 374 1095 424 OFF ON OFF ON CFM WATTS 1004 153 1019 210 1035 267 1038 321 1041 374 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1163 249 1173 311 1184 372 1179 426 1174 480 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1323 345 1328 411 1332 477 1320 532 1307 586 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1176 254 1188 317 1200 380 1195 437 1190 494 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1356 379 1362 446 1368 514 1353 568 1339 623 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1536 503 1536 575 1536 647 1512 699 1488 751 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1376 374 1367 429 1359 483 1354 547 1348 611 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1562 530 1562 604 1563 677 1531 720 1499 765 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1768 757 1759 830 1749 902 1654 866 1559 829 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 22-1814-08 11 *UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW8 LOW ON ON MEDIUM LOW OFF ON MEDIUM ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON MEDIUM ** ON OFF HIGH OFF OFF CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 1st Stage Capacity = 62,855 2nd Stage Capacity = 96,700 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 873 893 900 899 64 63 62 62 100 145 195 240 971 997 1006 1022 58 56 56 55 115 170 220 280 1136 1146 1165 1180 49 49 48 47 160 230 295 365 1258 1298 1319 1328 44 43 42 42 225 300 390 450 1260 1304 1329 1334 68 66 65 65 213 305 380 460 1464 1471 1478 1478 59 59 58 58 315 405 485 560 1631 1678 1690 1579 53 51 51 55 450 570 670 645 1846 1867 1794 1644 47 46 48 52 640 760 770 700 0.9 902 62 290 1029 54 335 1184 47 425 1286 44 490 1317 65 510 1350 64 540 1419 61 585 1498 57 650 NOTES: * First letter may be "A" or "T" ** Factory setting *UH2C100A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4.0 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 CFM WATTS 808 75 824 125 840 170 835 210 830 250 OFF CFM WATTS 938 100 963 160 959 205 964 255 975 310 ON OFF CFM WATTS 1058 150 1100 200 1121 265 1136 330 1142 395 ON OFF ON CFM WATTS 1004 120 1010 175 1027 230 1044 285 1050 345 OFF ON OFF OFF CFM WATTS 1141 170 1190 245 1214 310 1229 380 1234 450 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1336 250 1375 330 1387 410 1388 480 1384 545 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1153 180 1206 250 1230 320 1239 395 1244 460 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1390 285 1418 465 1439 445 1441 515 1373 540 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1575 400 1606 495 1632 590 1596 645 1445 590 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1388 290 1423 360 1444 440 1444 515 1390 540 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1610 415 1641 515 1666 635 1607 650 1449 595 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1847 630 1863 735 1816 780 1687 720 1532 665 SW 1 SW 2 SW 3 SW 4 LOW (350 CFM/TON) ON ON OFF ON NORMAL (400 CFM/TON) ON ON OFF HIGH (450 CFM/TON) ON ON LOW (350 CFM/TON) OFF NORMAL (400 CFM/TON) NOTES: *First letter may be "A" or "T" 1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 12 Pub. No. 22-1814-08 *UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st Stage Capacity = 62,855 2nd Stage Capacity = 96,700 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 HEATING 1ST STAGE HEATING 2ND STAGE LOW ON ON CFM TEMP. RISE WATTS 873 64 100 893 63 145 900 62 195 899 62 240 902 62 290 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 971 58 115 997 56 170 1006 56 220 1022 55 280 1029 54 335 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1136 49 160 1146 49 230 1165 48 295 1180 47 365 1184 47 425 HIGH OFF OFF CFM TEMP. RISE WATTS 1258 44 225 1298 43 300 1319 42 390 1328 42 450 1286 44 490 LOW ON ON CFM TEMP. RISE WATTS 1260 68 213 1304 66 305 1329 65 380 1334 65 460 1317 65 510 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1464 59 315 1471 59 405 1478 58 485 1478 58 560 1350 64 540 MEDIUM ** ON OFF CFM TEMP. RISE WATTS 1631 53 450 1678 51 570 1690 51 670 1579 55 645 1419 61 585 HIGH OFF OFF CFM TEMP. RISE WATTS 1846 47 640 1867 46 760 1794 48 770 1644 52 700 1498 57 650 NOTES: * First letter may be "A" or "T" ** Factory setting *UH2C100A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 AIRFLOW SETTING 5.0 EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 1163 222 1201 304 1209 375 1200 433 1199 495 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1339 331 1365 400 1366 477 1377 555 1382 636 OFF ON ON OFF CFM WATTS 1515 440 1538 535 1549 620 1553 708 1547 796 ON OFF OFF ON CFM WATTS 1339 331 1365 400 1366 477 1377 555 1382 636 ON OFF OFF OFF CFM WATTS 1550 471 1562 550 1574 645 1575 733 1564 813 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1744 626 1758 736 1770 838 1772 935 1760 1018 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1695 578 1709 728 1721 820 1772 930 1711 1007 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1919 862 1919 958 1905 1043 1831 1043 1709 982 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS NA NA NA NA NA NA NA NA NA NA HIGH (450 CFM/TON) LOW (350 CFM/TON) 4.0 DIP SWITCH SETTING NORMAL (400 CFM/TON) NOTES: *First letter may be "A" or "T" 1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 3. NA = Not allowed. Pub. No. 22-1814-08 13 *UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 1st Stage Capacity = 75,426 2nd Stage Capacity = 116,040 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 1090 1120 1080 1070 62 60 63 63 165 225 270 310 0.9 1010 67 380 LOW ON ON CFM TEMP. RISE WATTS MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1210 56 220 1200 56 280 1200 56 330 1180 57 395 1160 58 455 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1340 50 295 1360 50 350 1370 49 425 1380 49 495 1330 51 535 HIGH OFF OFF CFM TEMP. RISE WATTS 1430 47 390 1570 43 490 1580 43 565 1570 43 625 1390 49 565 LOW ON ON CFM TEMP. RISE WATTS 1660 63 485 1690 62 590 1680 62 640 1640 64 675 1460 72 600 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1870 56 675 1870 56 745 1810 58 770 1680 62 715 1490 70 625 NORMAL ** ON OFF CFM TEMP. RISE WATTS 2060 51 880 1990 53 890 1850 57 810 1710 61 750 1530 68 665 HIGH OFF OFF CFM TEMP. RISE WATTS 2200 48 1030 2090 50 965 1940 54 895 1790 58 830 1640 64 750 NOTES: * First letter may be "A" or "T" ** Factory setting *UH2D120A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 1210 220 1210 270 1220 325 1230 400 1230 445 OFF OFF CFM WATTS 1400 305 1440 390 1450 465 1450 510 1410 560 ON ON OFF CFM WATTS 1590 425 1600 520 1610 600 1600 645 1380 575 ON OFF OFF ON CFM WATTS 1390 305 1400 375 1430 445 1440 515 1420 565 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1620 420 1650 530 1670 595 1640 660 1480 600 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1840 600 1830 690 1820 765 1670 700 1490 620 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1800 570 1780 630 1780 705 1700 695 1530 615 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 2050 845 2010 875 1860 805 1710 735 1530 655 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2160 995 2040 935 1920 875 1780 805 1620 730 LOW (350 CFM/TON) OFF ON OFF NORMAL (400 CFM/TON) OFF ON HIGH (450 CFM/TON) OFF LOW (350 CFM/TON) SW 4 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 14 Pub. No. 22-1814-08 *DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 37,440 2nd STAGE CAPACITY = 57,600 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 600 600 600 600 600 LOW ON ON TEMP. RISE 56 56 56 56 56 WATTS 55 85 120 150 185 HEATING 1ST STAGE HEATING 2ND STAGE MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 675 50 65 675 50 105 675 50 140 675 50 175 675 50 205 NORMAL ** ON OFF CFM TEMP. RISE WATTS 750 45 85 750 45 125 750 45 160 750 45 210 750 45 260 HIGH OFF OFF CFM TEMP. RISE WATTS 850 40 115 850 40 155 850 40 205 850 40 260 850 40 320 LOW ON ON CFM TEMP. RISE WATTS 900 58 125 900 58 165 900 58 220 900 58 270 900 58 315 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1000 52 170 1050 50 230 1050 50 295 1050 50 335 1050 50 370 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1100 47 215 1150 45 285 1150 45 340 1150 45 395 1100 47 440 HIGH OFF OFF CFM TEMP. RISE WATTS 1300 40 330 1325 39 385 1325 39 455 1250 42 465 1200 43 470 NOTES: * First letter may be "A" or "T" ** Factory setting *DH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 1.5 2.0 2.5 3 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 525 45 525 70 525 100 525 135 525 160 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 600 55 600 85 600 120 600 150 600 185 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 675 65 675 105 625 140 675 175 675 205 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 700 70 700 115 700 145 700 185 700 220 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 800 100 800 135 800 175 800 225 800 280 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 900 125 900 165 900 220 900 270 900 330 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 875 115 875 160 875 210 875 260 875 310 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1000 150 1000 207 1000 265 1000 320 1000 380 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1125 215 1125 285 1125 340 1125 395 1125 440 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1050 175 1050 240 1050 305 1050 345 1050 380 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1200 240 1200 315 1200 385 1200 440 1100 410 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1350 330 1350 410 1350 500 1275 485 1170 450 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 22-1814-08 15 *DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE 1st STAGE CAPACITY = 49,920 2nd STAGE CAPACITY = 76,800 EXTERNAL STATIC PRESSURE DIP SWITCH SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 LOW ON ON CFM TEMP. RISE WATTS 800 56 130 800 56 170 800 56 210 790 56 245 - MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 900 49 162 900 49 210 900 49 260 900 49 295 - NORMAL ** ON OFF CFM TEMP. RISE WATTS 1000 44 205 1000 44 265 1000 44 310 1000 44 345 800 56 295 HIGH OFF OFF CFM TEMP. RISE WATTS 1170 38 305 1170 38 350 1170 38 400 1020 44 360 830 54 310 LOW ON ON CFM TEMP. RISE WATTS 1150 60 285 1150 60 345 1150 60 385 1020 67*** 360 830 83*** 305 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1275 54 380 1275 54 445 1200 57 425 1040 66*** 380 900 76*** 350 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1430 48 515 1340 51 490 1220 56 455 1090 63 410 930 74*** 380 HIGH OFF OFF CFM TEMP. RISE WATTS 1430 48 515 1340 51 490 1220 56 455 1090 63 410 930 74*** 380 NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX Temperature change value *DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.0 2.5 3.0 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) ON ON OFF ON CFM WATTS 700 95 700 105 700 115 680 200 670 235 NORMAL (400 CFM/TON) ON ON OFF OFF CFM WATTS 800 130 800 160 800 205 790 245 740 265 HIGH (450 CFM/TON) ON ON ON OFF CFM WATTS 900 160 900 215 900 255 900 300 750 270 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 875 145 875 185 875 240 875 280 760 270 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1000 205 1000 265 1000 310 1000 340 800 295 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1150 295 1150 340 1150 385 1020 350 800 300 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1050 235 1050 295 1050 340 1010 350 800 290 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1200 335 1200 385 1200 410 1040 365 840 310 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1350 455 1350 480 1210 435 1070 390 900 345 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 16 Pub. No. 22-1814-08 *DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 49,400 2nd STAGE CAPACITY = 76,000 DIP SWITCH SETTING EXTERNAL STATIC PRESSURE AIRFLOW SETTING SW 7 SW 8 0.1 0.3 0.5 0.7 0.9 CFM 800 800 800 790 LOW ON ON TEMP. RISE 56 56 56 56 WATTS 130 170 210 245 CFM 900 900 900 900 MEDIUM LOW OFF ON TEMP. RISE 49 49 49 49 HEATING WATTS 162 210 260 295 1ST CFM 1000 1000 1000 1000 800 STAGE MEDIUM ** ON OFF TEMP. RISE 44 44 44 44 56 WATTS 205 265 310 345 295 CFM 1170 1170 1170 1020 830 HIGH OFF OFF TEMP. RISE 38 38 38 44 54 WATTS 305 350 400 360 310 CFM 1150 1150 1150 1020 830 LOW ON ON TEMP. RISE 60 60 60 67*** 83*** WATTS 285 345 385 360 305 CFM 1275 1275 1200 1040 900 MEDIUM LOW OFF ON TEMP. RISE 54 54 57 66*** 76*** HEATING WATTS 380 445 425 380 350 2ND CFM 1430 1340 1220 1090 930 STAGE MEDIUM ** ON OFF TEMP. RISE 48 51 56 63 74*** WATTS 515 490 455 410 380 CFM 1430 1340 1220 1090 930 HIGH OFF OFF TEMP. RISE 48 51 56 63 74*** WATTS 515 490 455 410 380 NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX Temperature change value *DH2B080A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4.0 AIRFLOW SETTING DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 0.9 ON CFM WATTS 849 141 865 191 881 241 878 294 876 348 OFF OFF CFM WATTS 953 195 965 250 977 305 973 358 970 411 ON ON OFF CFM WATTS 1057 249 1065 309 1073 369 1069 422 1064 474 OFF ON OFF ON CFM WATTS 999 188 1003 241 1008 394 1018 354 1029 414 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1144 300 1150 362 1156 423 1160 486 1165 548 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1288 412 1297 482 1305 552 1303 617 1300 682 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1156 307 1165 374 1174 440 1177 502 1179 563 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1327 446 1335 518 1343 589 1325 641 1307 693 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1506 634 1502 703 1498 771 1418 746 1338 721 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1327 446 1335 518 1343 589 1325 641 1307 693 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 1525 656 1522 727 1518 797 1430 761 1341 725 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 1706 906 1635 881 1563 857 1471 813 1379 769 LOW (350 CFM/TON) ON ON OFF NORMAL (400 CFM/TON) ON ON HIGH (450 CFM/TON) ON LOW (350 CFM/TON) SW 4 NOTES: * First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 22-1814-08 17 *DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER 1st STAGE CAPACITY = 62,400 2nd STAGE CAPACITY = 96,000 AIRFLOW SETTING HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 7 SW 8 LOW ON ON MEDIUM LOW OFF ON MEDIUM ** ON OFF HIGH OFF OFF LOW ON ON MEDIUM LOW OFF ON MEDIUM ** ON OFF HIGH OFF OFF CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS CFM TEMP. RISE WATTS 0.1 923 61 110 1020 55 145 1156 48 185 1275 44 225 1298 66 235 1439 60 310 1639 53 430 1790 18 570 EXTERNAL STATIC PRESSURE 0.3 0.5 0.7 955 960 958 59 58 58 165 210 265 1047 1053 1042 53 53 54 190 250 295 1166 1172 1177 48 48 48 240 300 350 1305 1328 1328 43 42 42 290 365 445 1320 1335 1343 65 65 64 305 380 445 1459 1482 1483 59 58 58 390 470 550 1650 1650 1644 52 52 52 525 600 680 1818 1813 1708 47 47 50 670 770 750 0.9 947 59 310 1029 54 350 1178 48 420 1328 42 510 1343 64 520 1470 59 610 1496 58 640 1535 56 675 NOTES: * - First letter may be "A" or "T" ** Factory setting *** Above MAX temperature change *DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 2.5 3.0 3.5 4.0 AIRFLOW SETTING LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) LOW (350 CFM/TON) NORMAL (400 CFM/TON) HIGH (450 CFM/TON) DIP SWITCH SETTING SW 1 SW 2 SW 3 EXTERNAL STATIC PRESSURE SW 4 ON ON OFF ON ON ON OFF OFF ON ON ON OFF OFF ON OFF ON OFF ON OFF OFF OFF ON ON OFF ON OFF OFF ON ON OFF OFF OFF ON OFF ON OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON OFF CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS CFM WATTS 0.1 0.3 0.5 0.7 0.9 870 100 989 120 1124 175 1053 145 1186 195 1336 255 1216 190 1394 270 1579 395 1377 270 1599 425 1801 580 885 140 1018 180 1139 225 1075 200 1205 255 1366 340 1225 255 1422 360 1604 475 1412 355 1624 510 1818 690 887 185 1016 230 1130 275 1070 245 1220 310 1383 405 1235 320 1436 430 1610 555 1426 430 1636 585 1815 775 881 230 1012 285 1135 335 1070 295 1220 370 1385 470 1240 385 1437 505 1599 645 1433 510 1618 670 1694 735 876 270 999 325 1135 390 1049 350 1216 440 1381 545 1243 445 1430 580 1517 640 1428 575 1512 635 1525 660 NOTES: * - First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. 18 Pub. No. 22-1814-08 *DH2D120A9V5V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER AIRFLOW SETTING LOW 0.9 1000 67 340 ON ON OFF ON CFM TEMP. RISE WATTS 1200 56 230 1200 56 270 1200 56 330 1200 56 390 1200 56 450 NORMAL ** ON OFF CFM TEMP. RISE WATTS 1350 49 280 1350 49 340 1350 49 490 1350 49 470 1350 49 530 HIGH OFF OFF CFM TEMP. RISE WATTS 1550 43 400 1550 43 490 1550 43 560 1550 43 620 1450 46 600 LOW ON ON CFM TEMP. RISE WATTS 1550 66 380 1550 66 470 1550 66 540 1550 66 610 1450 71*** 690 MEDIUM LOW OFF ON CFM TEMP. RISE WATTS 1850 56 660 1850 56 750 1850 56 780 1700 60 720 1500 69 640 NORMAL ** ON OFF CFM TEMP. RISE WATTS 2050 50 860 2000 51 880 1850 56 810 1700 60 750 1550 66 670 HIGH OFF OFF CFM TEMP. RISE WATTS 2105 49 1000 2050 50 940 1900 54 880 1775 58 820 1625 63 750 MEDIUM LOW HEATING 1ST STAGE HEATING 2ND STAGE DIP SWITCH SETTING SW 8 SW 7 1st STAGE CAPACITY = 74,880 2nd STAGE CAPACITY = 115,200 EXTERNAL STATIC PRESSURE 0.1 0.3 0.5 0.7 CFM 1025 1025 1000 1000 TEMP. RISE 65 65 67 67 WATTS 150 200 240 290 NOTES: * First letter may be "A" or "T" ** Factory setting *DH2D120A9V5V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER OUTDOOR UNIT SIZE (TONS) 3.5 4.0 5 AIRFLOW SETTING DIP SWITCH SETTING EXTERNAL STATIC PRESSURE SW 1 SW 2 SW 3 SW 4 0.1 0.3 0.5 0.7 0.9 LOW (350 CFM/TON) OFF ON OFF ON CFM WATTS 1225 240 1225 280 1225 340 1225 400 1225 450 NORMAL (400 CFM/TON) OFF ON OFF OFF CFM WATTS 1400 310 1400 390 1400 470 1400 520 1400 570 HIGH (450 CFM/TON) OFF ON ON OFF CFM WATTS 1600 450 1600 520 1600 590 1600 640 1450 600 LOW (350 CFM/TON) ON OFF OFF ON CFM WATTS 1400 300 1400 380 1400 450 1400 520 1400 570 NORMAL (400 CFM/TON) ON OFF OFF OFF CFM WATTS 1600 460 1600 530 1600 610 1600 670 1450 600 HIGH (450 CFM/TON) ON OFF ON OFF CFM WATTS 1800 610 1800 700 1800 760 1650 690 1500 630 LOW (350 CFM/TON) OFF OFF OFF ON CFM WATTS 1750 580 1750 640 1750 720 1650 680 1450 610 NORMAL (400 CFM/TON) OFF OFF OFF OFF CFM WATTS 2000 830 2000 860 1850 800 1700 740 1550 660 HIGH (450 CFM/TON) OFF OFF ON OFF CFM WATTS 2100 970 2000 910 1900 850 1650 780 1600 710 NOTES: * - First letter may be "A" or "T" 1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value. 2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting; NORMAL airflow (400 cfm/ton) is typical setting; HIGH airflow (450 cfm/ton) is DRY CLIMATE setting. Pub. No. 22-1814-08 19 Maximum Vent Length Table VENT LENGTH TABLE ALTITUDE MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET FOR VENT AND INLET AIR (SEE NOTES) 0-7,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3VA 200 200 200 *UH/DH2B080A9V3VA *UH/DH2B080A9V4VA 50 120 200 *UH/DH2C100A9V4VA *UH2C100A9V5VA Not Allowed 60 200 *UH/DH2D120A9V5VA Not Allowed Not Allowed 200 7,000-9,500 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3VA 100 100 100 *UH/DH2B080A9V3VA *UH/DH2B080A9V4VA 25 60 100 *UH/DH2C100A9V4VA *UH2C100A9V5VA Not Allowed 30 100 *UH/DH2D120A9V5VA Not Allowed Not Allowed 100 9,500-12,000 Feet 2 INCH PIPE 2.5 INCH PIPE 3 or 4 INCH PIPE *UH/DH2B060A9V3VA 50 50 50 *UH/DH2B080A9V3VA *UH/DH2B080A9V4VA Not Allowed 30 50 *UH/DH2C100A9V4VA *UH2C100A9V5VA Not Allowed Not Allowed 50 *UH/DH2D120A9V5VA Not Allowed Not Allowed 50 NOTES: * - First letter may be "A" or "T" 1. Minimum vent length for all models: 3' horizontal or 3' vertical. 2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapters at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never smaller than the vent pipe. 3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes). 4. One SHORT radius 90° elbow is equivalent to 10' of 3" or 4" pipe and one LONG radius elbow is equivalent to 6' of 3" or 4" pipe. One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow. 5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet. 6. Pipe adapters are field supplied (except for the *UH/DH2D120 models). 7. For Canadian applications ONLY, IPEX 196006 may be used for horizontal and vertical terminations. IPEX 081216, IPEX 081218, and IPEX 081219 may only be used for horizontal vent terminations. Equivalent lengths are IPEX 196009 = 5 feet, IPEX 081216 = 11 feet, IPEX 081218 = 16 feet, and IPEX 081219 = 21 feet 20 Pub. No. 22-1814-08 Electrical Data *UH2 WIRING DIAGRAM Pub. No. 22-1814-08 21 From drawing D344303 Electrical Data *UH2 SCHEMATIC DIAGRAM From drawing D344303 22 Pub. No. 22-1814-08 Electrical Data *DH2 WIRING DIAGRAM Pub. No. 22-1814-08 23 From drawing D344304 Electrical Data *DH2 SCHEMATIC DIAGRAM 24 From drawing D344304 Pub. No. 22-1814-08 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY Pub. No. 22-1814-08 25 Field Wiring FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING (OUTDOOR SECTION WITHOUT TRANSFORMER) 26 Pub. No. 22-1814-08 (ALL DIMENSIONS ARE IN INCHES) *UH2 UPFLOW / HORIZONTAL OUTLINE DRAWING Dimensions Pub. No. 22-1814-08 27 (ALL DIMENSIONS ARE IN INCHES) *DH2 DOWNFLOW / HORIZONTAL OUTLINE DRAWING Dimensions 28 Pub. No. 22-1814-08 Notes Pub. No. 22-1814-08 29 Trane 6200 Troup Highway Tyler, TX 75707 www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Page Count : 30 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:2e78616e-ca0d-4e60-8895-0d414b3cb75c Producer : Adobe PDF Library 9.9 Trapped : False Acces flag : F Alt order nbr : Alt order nbr type : Bw color : B Date published : 08/01/2012 Dept id : 54 Topic focused id : EN|TRANE Price : 0 Cur flag : T Lit class id : PL Lit length : 30 Lit order nbr : 22-1814-08 Lit type id : PRD Media id : ELO Model : NONE Prod class : UN Prod family id : 105 Prod : FURN Topic related id : TRN-FLD|STARTUP|RRR|OWN/DEV|OPER|INST Restrct flag : F Source date : nulldate Source filename : Stocking loc id : None Supceded by : Supceded by date : 01/01/2010 Unit flag : T Branding : Trane Lol language : EN Object id : 090102b182f7ca31 Object name : 22-1814-08_08012012 Chronicle id : 090102b181327c37 Filename : 82f7ca31.pdf Abstract : XV 95 - TUH2B060A9V3VA, TUH2B080A9V3VA, TUH2B080A9V4VA, TUH2C100A9V4VA, TUH2C100A9V5VA, TUH2D120A9V5VA, TDH2B060A9V3VA, TDH2B080A9V3VA, TDH2B080A9V4VA, TDH2C100A9V4VA, TDH2D120A9V5VA, Direct Vent with Variable Speed Blower and Variable Speed Inducer. Hist model : TUH2B060A9V3VAA|TUH2B080A9V3VAA|TDH2B060A9V3VAA|TDH2B080A9V3VAA|TUH2C100A9V4VA|TDH2C100A9V4VA|TUH2D120A9V5VA|TDH2D120A9V5VA|TUH2B080A9V4VA|TUH2C100A9V5VA|TDH2B080A9V4VA Create Date : 2012:08:30 16:43:37-05:00 Modify Date : 2012:09:10 08:59:54-05:00 Metadata Date : 2012:09:10 08:59:54-05:00 Creator Tool : Adobe InDesign CS5 (7.0.4) Instance ID : uuid:3f55ac69-bbaa-429d-9c44-65c7fcbe7264 Rendition Class : proof:pdf Document ID : adobe:docid:indd:6f2dcbba-f1ef-11e1-9309-9e72ea85ae7d Original Document ID : adobe:docid:indd:6f2dcbba-f1ef-11e1-9309-9e72ea85ae7d History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:C2A703E0F0F1E111BE29978AB437D201, xmp.iid:742D0DE0F0F1E111BE29978AB437D201, xmp.iid:8CF89F4EF1F1E111BE29978AB437D201, xmp.iid:21581084F1F1E111BE29978AB437D201, xmp.iid:20D4A026D7F2E111AF66C1CD07AAFE66, xmp.iid:2ADECC4CD7F2E111AF66C1CD07AAFE66, xmp.iid:38AD2FA5D8F2E111AF66C1CD07AAFE66, xmp.iid:FB4AE2C3D8F2E111AF66C1CD07AAFE66, xmp.iid:2A40D1AED9F2E111AF66C1CD07AAFE66, xmp.iid:8054B6F6D9F2E111AF66C1CD07AAFE66, xmp.iid:40C0964EDAF2E111AF66C1CD07AAFE66, xmp.iid:F2737C9ADAF2E111AF66C1CD07AAFE66, xmp.iid:1C0859CADAF2E111AF66C1CD07AAFE66, xmp.iid:95B7ED15DBF2E111AF66C1CD07AAFE66, xmp.iid:AF2D0935DBF2E111AF66C1CD07AAFE66, xmp.iid:7596175CDBF2E111AF66C1CD07AAFE66, xmp.iid:372FD574DBF2E111AF66C1CD07AAFE66, xmp.iid:4191198FDBF2E111AF66C1CD07AAFE66, xmp.iid:FE884546DCF2E111AF66C1CD07AAFE66, xmp.iid:3E49D226DFF2E111AF66C1CD07AAFE66, xmp.iid:D047365EE8F2E111AF66C1CD07AAFE66, xmp.iid:E05F46D3E9F2E111AF66C1CD07AAFE66, xmp.iid:A7840FC0EAF2E111AF66C1CD07AAFE66, xmp.iid:B4788613EBF2E111AF66C1CD07AAFE66 History When : 2012:08:29 10:47:45-05:00, 2012:08:29 10:47:45-05:00, 2012:08:29 10:50:50-05:00, 2012:08:29 10:52:20-05:00, 2012:08:30 14:16:07-05:00, 2012:08:30 14:17:53-05:00, 2012:08:30 14:26:49-05:00, 2012:08:30 14:27:41-05:00, 2012:08:30 14:34:15-05:00, 2012:08:30 14:36:15-05:00, 2012:08:30 14:38:43-05:00, 2012:08:30 14:40:50-05:00, 2012:08:30 14:42:10-05:00, 2012:08:30 14:44:17-05:00, 2012:08:30 14:45:09-05:00, 2012:08:30 14:46:15-05:00, 2012:08:30 14:46:56-05:00, 2012:08:30 14:47:41-05:00, 2012:08:30 14:52:48-05:00, 2012:08:30 15:13:24-05:00, 2012:08:30 16:19:22-05:00, 2012:08:30 16:29:48-05:00, 2012:08:30 16:36:25-05:00, 2012:08:30 16:38:45-05:00 History Software Agent : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0 History Changed : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata N Pages : 30 Doc Change Count : 309 Format : application/pdf Title : 22-1814-08 08/01/2012 Trane Product Data Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace XV95 Models Tagged PDF : Yes Creator : Adobe InDesign CS5 (7.0.4) Acces Flag : F Alt Order Nbr : Alt Order Nbr Type : Bw Color : B Hist Model : TUH2B060A9V3VAA|TUH2B080A9V3VAA|TDH2B060A9V3VAA|TDH2B080A9V3VAA|TUH2C100A9V4VA|TDH2C100A9V4VA|TUH2D120A9V5VA|TDH2D120A9V5VA|TUH2B080A9V4VA|TUH2C100A9V5VA|TDH2B080A9V4VA Date Published : 08/01/2012 Dept Id : 54 Topic Focused Id : EN|TRANE Cur Flag : T Lit Class Id : PL Lit Length : 30 Lit Order Nbr : 22-1814-08 Lit Type Id : PRD Media Id : ELO Prod Class : UN Prod Family Id : 105 Topic Related Id : TRN-FLD|STARTUP|RRR|OWN/DEV|OPER|INST Restrct Flag : F Source Date : nulldate Source Filename : Stocking Loc Id : None Supceded By : Supceded By Date : 01/01/2010 Unit Flag : T Lol Language : EN Object Id : 090102b182f7ca31 Object Name : 22-1814-08_08012012 Chronicle Id : 090102b181327c37EXIF Metadata provided by EXIF.tools