Trane Varitrac Dampers Brochure VAV SLB008 EN.p65
2015-04-02
: Trane Trane-Varitrac-Dampers-Brochure-684386 trane-varitrac-dampers-brochure-684386 trane pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
CO2 Duct Sensor and CO2 Wall Sensor Figure 1: CO2 Duct Sensor The wall and duct-mounted carbon dioxide (CO2) sensors are designed especially for demand-controlled ventilation zone applications. The sensor is compatible withTrane VAV and VariTrac® controllers. Long-term stability and reliable sensing performance come from advanced silicon based NonDispersive Infrared (NDIR) technology. When connected to a building automation system and the appropriate ventilation equipment, the Trane CO2 sensors measure and record carbon dioxide in parts-per-million (ppm) in occupied building spaces.These carbon dioxide measurements are typically used to identify under-ventilated building zones and to override outdoor airflow beyond design ventilation rates if the CO2 exceeds acceptable levels. Please visit trane.com or contact a local Trane representative for more information. Figure 2: CO2 Wall Sensor Table 1: Sensor Specifications Duct Measuring Range Accuracy at 77°F (25°C) Response time Operating Temperature Storage Temperature Wall- or Duct-mounted < ± (40 ppm CO2 + 3% of reading) < ± (30 ppm CO2 + 3% of reading) Recommended calibration interval 5 years 1 minute (0-63%) 23 to 113°F (-5 to 45°C) 59 to 95°F (15 to 35°C) -4 to 158°F (-20 to 70°C) Humidity Range 0–85% relative humidity (RH) Output Signal (jumper selectable) 4-20 mA, 0–20 mA, 0–10 VDC Resolution of analog outputs Power Supply Power Consumption Housing Material Dimensions Features Wall 0–2000 parts per million (ppm) 10 ppm CO2 Nominal 24 VAC < 5 VA ABS plastic 3 1/8" x 3 1/8" x 7 3/4" 4 1/4" x 3 1/8" x 1 7/16" (80 mm x 80 mm x (108 mm x 80 mm x 200 mm) 36 mm) Measures CO2 in ppm. NDIR SensingTechnology Demand-Controlled Ventilation ©2002 American Standard, Inc. All rights reserved VAV-SLB008-EN Figure 3: Dimensional Data 36 mm (1.4375") 108 mm (4.25") 80 mm (3.125") Specifications: Measuring range: 0–2000 parts per million (ppm) CO2 Accuracy at 25˚C: <± (40 ppm CO2 + 3% of reading) (includes repeatability and calibration uncertainty) Non-linearity: < 1% full scale (FS) Temperature dependence of output: 0.3% FS/degrees C Long-term stability: <5.0" FS/5 years Recommended calibration interval: 5 years Response time: 1 minute (0–63%) Operating temperature: From 59 to 95˚F (15 to 35˚C) Storage temperature: From -4 to 158˚F (-20 to 70˚C) Humidity range: 0–85% relative humidity (FH) Output signals (jumper selectable): 4–20 mS, 0–20 mA, 0–10 Vdc Resolution of analog outputs: 10 ppm CO2 Recommended external load: Current output: max. 500 ohms Voltage output: min. 1000 ohms Power supply: Nominal 24 Vac Power consumption: <5 VA Warm-up time: < 15 minutes Housing material: ABS plastic Mounting holes: For standard Asian, European, and North American junction boxes Trane An American Standard Company www.trane.com For more information contact your local district office or e-mail us at comfort @trane.com ©2002 American Standard, Inc. All rights reserved Literature Order Number VAV-SLB008-EN File Number SB-TD-VAV-000-SLB008-EN-0602 Supersedes New Stocking Location La Crosse Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Page Count : 2 Create Date : 1910:20:62 80:95:71 Producer : Acrobat Distiller 3.01 for Windows Author : lahke Creator : PageMaker 6.5 Title : VAV-SLB008-EN.p65EXIF Metadata provided by EXIF.tools