Trane Voyager 12 5 To 25 Tons Brochure SRV SLB073 EN 10/06/2010 Light Commercial Rooftop Units Education Applications
2015-04-02
: Trane Trane-Voyager-12-5-To-25-Tons-Brochure-684196 trane-voyager-12-5-to-25-tons-brochure-684196 trane pdf
Open the PDF directly: View PDF .
Page Count: 8
Light commercial
rooop units
Education applications
Our light commercial
rooftop units offer more
and cost you less.
When deciding which rooop unit is best for
your building, remember that the initial purchase
is only part of the equation.
You’ll save in every aspect of your budget when
you choose Trane.
The superior engineering of our Precedent™
and Voyager™ Light Commercial rooop units
delivers high reliability, easier installation, less
maintenance, reduced operating costs and less
upfront expense.
In short, a lower total cost of ownership.
Easy on your budget
Trane Precedent and Voyager Light Commercial
units oer superior engineering while delivering
high eciency air conditioning for new
construction as well as replacement
Less to install. Less to maintain.
Less to operate.
installations and retrofits. Unit eciency
surpasses EER minimum by 12%.
Precedent high-eciency rooop units are 15%
more ecient than typical packaged equipment.
Energy eciency can be increased by adding
Trane controls, installation, maintenance and
Service Level Agreements.
Trane oers:
• Lower supply fan energy costs—a savings
of 7-10%—when the unit operates in
continuous fan operation mode.
• Three stages of cooling on high eciency,
dual-compressor units for more precise
temperature control, helping save money
all year.
• Industry-leading IEER, helping to stretch an
energy budget and provide quicker payback on
investment.
Easy to install
These compact rooop units fit into the
same roofcurb as current models, reducing
installation time and costs. Preconfigured
units come with factory- installed options
to eliminate expensive and time-consuming
accessory field installations.
Easy on the roof
Models within the Precedent and Voyager Light
Commercial lines are as much as 46% lighter
than comparable units.
Easy to maintain
Trane Precedent and Voyager Light Commercial
rooop units oer easy access to filters,
ReliaTel™ micropro-
cessor controls are
available on 3- to
25-ton units.
2 Trane Light Commercial Rooop Units
compressors and controls through single-side
access doors.
• No belts. Precedent high eciency units
feature direct-drive fan motors, reducing
maintenance requirements and costs.
• Test mode operation can indicate where
potential problems exist, reducing overall
service cost.
• Unit designed for easy coil cleaning to
eliminate maintenance time, thereby increasing
unit eciency.
Improved indoor air quality
MERV 13 high eciency filtration option
reduces the amount of particles in the air and
provides better air quality.
• C02 controls available to bring in more outside
air when occupancy levels are high.
• Hot gas reheat available for humidity control.
• Cleanable dual sloped drain pans to reduce
microbial growth.
Quiet operation
Select models of Precedent Light Commercial
units include an ultra quiet plenum fan, which
enables them to meet or exceed rigorous
requirements for acoustic standards compliance.
Because of the plenum fan and other sound
mitigating design techniques—along with
soware modeling tools such as the Trane
Acoustics Program—these units can provide a
cost eective solution for your building and help
deliver a quieter environment.
3
Right for schools
Designed primarily for classroom use, the Precedent line offers models in
the 3- to 10- ton range, while the Voyager Light Commercial line features
rooftop units from 12½ to 25 tons—perfect for lunchrooms, gymnasiums
and auditoriums.
Trane Precedent and Voyager Light Commercial rooftop units provide
quieter operation and can be configured to comply with rigorous acoustic
standards. Studies show when noise levels are reduced, test scores improve.
And because of advanced filtration technology, both lines deliver
improved indoor air quality. A healthier learning environment helps reduce
absenteeism and improve teacher retention.
Light Commercial Rooftop Unit
Precedent™ (3 - 10 Ton)
Voyager™ (12.5 - 25 Ton)
4 Trane Light Commercial Rooop Units
A
E
F
H
J
B
C
5
Lower Cost of Ownership
MERV 13 Filter
High eciency filtration allows
for delivering improved indoor
air quality—a key qualifying
component for LEED EQ credit 5.
Direct-Drive Plenum Fan*
Potential to achieve quieter
operating environment. High
eciency, direct-drive fan allows
for ease of service and overall
lower cost of ownership. Easier
start-up time in reducing overall
time on the jobsite. No belts
means less waste.
Phase Monitor
Protects unit from phase reversal,
loss of phase and voltage
imbalance.
Three Stages of Cooling**
Enhanced comfort through
matching cooling load, savings.
Allows for increased part load
eciency.
More Ecient Servicing
Foil-Faced Insulation
Edges captured and sealed,
reducing chance for insulation
fibers in the airstream. Easy to
clean.
Drain Pan
Non-corrosive, double sloped,
reversible condensate drain pan
is easy to clean and easy to
install.
Condenser Coil
Patent-pending multi-row
condenser coil designed with
gaps for easy cleaning.
Color-Coded,
Numbered Wiring
Saves time and money
when servicing and diagnosing
the unit.
Hinged Access Doors
Permit easy entry to the unit’s
service access areas. Also
reduces opportunity
for roof damage.
ReliaTel
Microprocessor Controls
Onboard diagnostics allows
for easy startup and trouble
shooting.
AE
F
G
G
H
I
J
I
B
C
D
D
* Standard on all dual-compressor,
high eciency Precedent units
** Standard on all dual-compressor,
high eciency units
6 Trane Light Commercial Rooop Units
The Plenum Fan: Key to a Quieter Classroom
A standard feature on our dual-compressor, high eciency Precedent units, the plenum fan oers
the quiet, unobtrusive operation you need for an eective learning environment, as well as reduced
maintenance costs.
• Backward incline blade design performs at a whisper, allowing for a more ecient indoor sound
mitigation plan.
• Fewer blades to clean and maintain.
• High eciency, variable-speed indoor fan motor:
– Requires less power, reducing energy costs.
– Direct-drive motor eliminates maintenance associated with belt replacement and tensioning.
7
Industry-leading eciencies up to 13 EER
VOYAGER™ PRECEDENT™ VOYAGER™ PRECEDENT™
Product
Oering
Nominal Model Capacity SEER/EER Low Med. High L x W x H (in.) Shipping
Size (MBH) Weight (lbs.)
3 T/YSC036E 37.2 13 SEER 60 80 120 69⅞ x 44¼ x 36¼ 514
4 T/YSC048E 49.4 13 SEER 60 80 120 69⅞ x 44¼ x 36¼ 525
5 T/YSC060E 62.4 13 SEER 60 80 120 69⅞ x 44¼ x 36¼ 682
6 T/YSC072E 75 11.2 60 80 120 88⅝ x 53¼ x 40⅞ 936
7.5 T/YSC090E 90 11.2 80 120 150 88⅝ x 53¼ x 46⅞ 988
7.5 T/YSC092E 94 11.2 120 150 200 88⅝ x 53¼ x 46⅞ 1059
8.5 T/YSC102E 102.1 11.2 120 150 200 88⅝ x 53¼ x 46⅞ 1096
10 T/YSC120E 118 11.2 150 200 250 88⅝ x 53¼ x 46⅞ 1173
12.5 T/YC*150E 158 11 -- 150 250 107⅝ x 71⅝ x 50⅛ 1952
15 T/YC*180E 189 11 -- 250 350 122⅝ x 85⅝ x 54 2474
17.5 T/YC*210E 212 11 -- 250 350 122⅝ x 85⅝ x 54 2573
20 T/YC*240E 250 10.2 -- 250 400 122⅝ x 85⅝ x 54 2575
25 T/YC*300E 282 10 -- 250 400 122⅝ x 85⅝ x 54 2583
3 T/YHC036E 38 15 SEER 60 80 120 69⅞ x 44¼ x 36¼ 637
4 T/YHC048E 49 15 SEER 60 80 120 88⅝ x 53¼ x 40⅞ 869
5 T/YHC060E 62 15 SEER 60 80 130 88⅝ x 53¼ x 40⅞ 984
6 T/YHC072E 68 12.6 80 120 150 88⅝ x 53¼ x 46⅞ 997
7.5 T/YHC092E 89 13 120 150 200 99¾ x 63¼ x 50⅞ 1334
8.5 T/YHC102E 98.2 13 120 150 200 99¾ x 63¼ x 50⅞ 1359
10 T/YHC120E 119 12.5 150 200 250 99¾ x 63¼ x 50⅞ 1369
12.5 T/YC*151E 149 12 -- 150 200 122⅝ x 85⅝ x 54 2610
15 T/YC*181E 181 12 -- 250 350 122⅝ x 85⅝ x 54 2613
17.5 T/YC*211E 215 12 -- 250 350 122⅝ x 85⅝ x 64⅛ 2677
20 T/YC*241E 264 11 -- 250 400 122⅝ x 85⅝ x 64⅛ 2680
25 T/YC*301E 285 11 -- 250 400 122⅝ x 85⅝ x 64⅛ 2684
COOLING DATA
HEATING DATA
PHYSICAL DATA
Specifications
Give your students—and your managers—a clear view of your school’s
energy use.
A valuable addition to your rooop unit, the Trane Education Green Dashboard provides a real-time, browser-based view of your
rooop unit’s energy use. The dashboard—a pre-engineered, integrated solution for Tracer Summit building control units—
includes two versions: an interface designed for teaching kids about energy, and another that provides technical data and tools
for facility sta to help you better manage energy in your school.
For students in grades 4-10:
• Provides an interactive classroom learning experience and
teaches students about smarter energy use
• Supports LEED ID Credit 3: “Building as a Teaching Tool”
• Includes an Energy Audit Game and lab, inter-school energy
savings competitions, and calculators to measure dollar savings
from various energy conservation measures
• Includes full curriculum guide for both teachers and students
For facility sta:
• Helps you monitor energy use by providing real-time and historical
information for your school and others in your district
• Provides cost-per-square-foot data
• Tracks usage with costs, giving you a detailed understanding of how
energy usage aects your budget
• Includes calculators for determining savings from high eciency
lighting, use of solar energy, various thermostat savings and more
Keep your rooop unit performing at
its peak.
A properly maintained unit—which includes coil cleaning, filter change-outs and routine indoor fan maintenance—will retain
its eciency longer and result in an extended life and lower total cost of ownership. Please contact your local Trane Service
Representative for more information.
Ingersoll Rand (NYSE:IR) is a world leader in creating and sustaining safe, comfortable and ecient environments in commercial, residential and
industrial markets. Our people and our family of brands—including Club Car®, Hussmann®, Ingersoll Rand®, Schlage®, Thermo King® and Trane®—
work together to enhance the quality and comfort of air in homes and buildings, transport and protect food and perishables, secure homes and
commercial properties, and increase industrial productivity and eciency. We are a $13 billion global business committed to sustainable business
practices within our company and for our customers.
© 2010 Trane All rights reserved
SRV-SLB073-EN October 06, 2010 ingersollrand.com
Produced on post-consumer recycled paper, using
environmentally friendly print practices that reduce waste.