Cautions, Warnings and Notices
WARNING

Owner Manual

Indicates a potentially hazardous situation which, if not avoided, could
result in death or serious injury
CAUTION

Packaged Rooftop Air Conditioners
Voyager™ Gas/Electric
For Servicers and Owners Use
Model

12½ through 25 Ton Packaged Gas/Electric
27½ through 50 Ton Packaged Gas/Electric

SAFETY WARNING

© 2012 Trane
All rights reserved

NOTICE
Indicates a situation that could result in equipment or property-damage
only accidents.

Only qualified personnel should install and service the equipment. The
installation, starting up, and servicing of heating, ventilating, and airconditioning equipment can be hazardous and requires specific
knowledge and training. Improperly installed, adjusted or altered
equipment by an unqualified person could result in death or serious injury.
When working on the equipment, observe all precautions in the literature
and on the tags, stickers, and labels that are attached to the equipment.

May 2012

Indicates a potentially hazardous situation which, if not avoided, could
result in minor or moderate injury. It may also be used to alert against
unsafe practices.

Important: Environmental Concerns! Scientific research has shown
that certain man-made chemicals can affect the earth's naturally occurring
stratospheric ozone layer when released to the atmosphere. In particular,
several of the identified chemicals that may affect the ozone layer are
refrigerants that contain Chlorine, Fluorine and Carbon (CFCs) and those
containing Hydrogen, Chlorine, Fluorine and Carbon (HCFCs). Not all
refrigerants containing these compounds have the same potential impact
to the environment. Trane advocates the responsible handling of all
refrigerants-including industry replacements for CFCs such as HCFCs and
HFCs.
Important: Responsible Refrigerant Practices! Trane believes that
responsible refrigerant practices are important to the environment, our
customers, and the air conditioning industry. All technicians who handle
refrigerants must be certified. The Federal Clean Air Act (Section 608) sets
forth the requirements for handling, reclaiming, recovering and recycling of
certain refrigerants and the equipment that is used in these service
procedures. In addition, some states or municipalities may have additional
requirements that must also be adhered to for responsible management of
refrigerants. Know the applicable laws and follow them.

2

3
WARNING

Personal Protective Equipment Required!
Installing/servicing this unit could result in exposure to electrical,
mechanical and chemical hazards. Before installing/servicing this unit,
technicians MUST put on all Personal Protective Equipment (PPE)
recommended for the work being undertaken. ALWAYS refer to
appropriate MSDS sheets and OSHA guidelines for proper PPE. When
working with or around hazardous chemicals, ALWAYS refer to the
appropriate MSDS sheets and OSHA guidelines for information on
allowable personal exposure levels, proper respiratory protection and
handling recommendations. If there is a risk of arc or flash, technicians
MUST put on all necessary Personal Protective Equipment (PPE) in
accordance with NFPA70E for arc/flash protection PRIOR to servicing the
unit. Failure to follow recommendations could result in death or serious
injury.

Overview of Manual

Inspection
• Unpack all components of the kit.
• Check carefully for any shipping damage. If any damage is found it must
be reported immediately and a claim made against the transportation
company.
• Visually inspect the components for shipping damage as soon as
possible after delivery, before it is stored. Concealed damage must be
reported within 15 days.
• If concealed damage is discovered, stop unpacking the shipment.
• Do not remove damaged material from the receiving location. Take
photos of the damage, if possible. The owner must provide reasonable
evidence that the damage did not occur after delivery.
• Notify the carrier’s terminal of damage immediately by phone and by
mail. Request an immediate joint inspection of the damage by the
carrier and the consignee.
Important: Do not attempt to repair any damaged parts until the parts are
inspected by the carrier’s representative.

One copy of this document ships inside the control panel of each unit and
is customer property. It must be retained by the unit’s maintenance
personnel.
Your combination gas heating/cooling unit is designed to provide comfort
all year long with safe, efficient, trouble-free operation. It is important that
you understand how to operate and maintain your unit to keep it operating
safely and efficiently. This manual will acquaint you with these important
procedures.

Model Number Description
All products are identified by a multiple-character model number that
precisely identifies a particular type of unit. Its use will enable the
owner/operator, installing contractors, and service engineers to define the
operation, specific components, and other options for any specific unit.
When ordering replacement parts or requesting service, be sure to refer to
the specific model number and serial number printed on the unit
nameplate.

RT-SVU04F-EN

4

5

Important Safety Instructions
WARNING
Safety Instructions!
Failure to follow instructions in this section could result in death, serious
injury, and property damage.

Safety Instructions Before Operating the Unit
• This appliance does not have a pilot. It is equipped with an ignition
device which automatically lights the burner. Do not try to light the
burner by hand.
• BEFORE OPERATING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air and
will settle on the floor.
What To Do If You Smell Gas

General Safety Instructions
• Do not store combustible materials, gasoline or other flammable
vapors and liquids near the unit.
• Should overheating occur, or the gas supply fail to shut off, shut off the
manual gas valve to the furnace before shutting off the electrical supply.
• Do not use this furnace if any part has been under water. Immediately
call a qualified service technician to inspect the furnace and to replace
any part of the control system and any gas control system and any gas
control which has been under water.
• Never perform any maintenance procedures until the electrical power
and/or gas supply to the unit has been turned off.
• Never remove any panels from the unit while it is operating.
• Never remove panels or parts from this unit that are not discussed in
this manual.
• Never cover the unit, since it is designed to operate year-round.
• The furnace area must be kept clear and free of combustible materials,
gasoline and other flammable vapors and liquids.
• For proper and safe operation the furnace needs air for combustion and
ventilation. Do not block or obstruct air openings on the furnace, air
openings communicating with the areas in which the furnace is
installed, and the spacing around the furnace.
At installation and the beginning of each heating season, a qualified service
technician should examine the furnace to ensure:
• All flue products carrying areas external to the furnace, (i.e., chimney,
vent connector, etc.), are clear and free of obstructions.
• The physical support of the furnace is sound and without sagging,
cracks, gaps, etc., around the base so as to provide a seal between the
support and the base.
• There are no obvious signs of deterioration of the furnace.

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor’s phone. Follow the
gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire department.

6

7

Temperature Control Devices

Air Filters

Room thermostats and zone sensors are delicate temperature control
devices.
Thermostats’ main function is to energize and de-energize the heating or
cooling circuit to maintain the temperature setting you select.
Zone sensors’ main function is to sense the room temperature to allow the
unit controls to activate the heating and cooling functions to maintain the
temperature setting you select.
Many thermostats and zone sensors contain a room thermometer to
indicate the approximate room temperature, and a temperature scale at the
adjustment indicator to select the desired indoor air temperature. In
addition, most controls have a selector mode switch with Heat, Off and Cool
positions, and a fan switch with On and Auto positions.
When the selector switch is positioned at Off, your unit will not operate in
either the heat or cool modes. If the selector switch is set at Heat, the unit
will automatically cycle on and off to maintain the desired temperature
setting. The unit will also operate automatically when the selector switch is
positioned at Cool.
The fan selector switch can be used to operate the indoor fan continuously
by positioning it at On. When set at Auto, the fan will only operate when
required during the heating or cooling cycles.
To ensure that the thermostat or zone sensor operates properly, it must be
level and positioned to avoid the influence of such external heat sources
such as lamps, televisions or other heat producing appliances.

It is very important to keep the central duct system air filters clean. Be sure
to inspect them at least once each month when the system is in constant
operation. (In new homes, check the filters every week for the first 4 weeks.)
See Table 1 for the required filter size(s).
If you have disposable type filters, replace them with new filters of the same
type and size. Do not attempt to clean disposable filters.
Permanent type filters can be cleaned by washing them with a mild
detergent and water. Ensure that the filters are thoroughly dry before
reinstalling them in the unit (or duct system).
Note: It may be necessary to replace permanent filters annually if washing
fails to clean the filter, or if the filter shows signs of deterioration. Be sure
to use the same type and size as was originally installed.
Table 1.

Recommended filter size
Model

YS*150F

Qty

Filter Size
(L x W x D)

2

20 x 20 x 2

4

20 x 25 x 2

YSD155F, 180F, 175F, 210F, 240F, 250F, 300F
YHD150F
WSD150E,180E

20 x 20 x 2

4

YSH155F, 180F, 175F, 210F, 240F, 250F, 300F
YHH150F
WSH150E,180E

8

20 x 25 x 2

YHD180F, 210F, 240F, 300F
WSD240E

8

20 x 20 x 2

4

16 x 20 x 2

YHH180F, 210F, 240F,300F
WSH240E

12

20 x 20 x 2

YC*330-420

16

16 x 20 x 2(a)

YC*480-600

17

16 x 20 x 2(a)

20 x 25 x 2

1. * = Applies to both downflow and horizontal.
2. Filters not provided with 4- and 5- ton horizontal units.
(a) 4” Filters are optional. Replace with same size as originally supplied.

8

Heating System
Heating Cycle Operation

9
Figure 1.

10

1. Set the temperature control to lowest setting.
2. Turn off all electric power to the appliance.
3. This appliance is equipped with an ignition device which automatically
lights the burner. Do not try to light the burner by hand.
Note: Depending on heater size, the gas valve control will be a knob, as
shown in Figure 1, or a toggle switch.

WARNING
Risk of Fire or Explosion!
Use only your hand to push in or turn the gas control knob. Never use
tools. If the knob does not push in or turn by hand, don’t try to repair it; call
a qualified service technician.
Failure to follow instructions could result in death or serious injury.

Safety Controls

Operating Instructions

5. Replace panel removed in Step 3.

Gas valve control knob (toggle switch used in some heater
sizes)

A normal heating cycle begins when the air temperature in your home
drops below the selected setting. The control then energizes the heating
electrical circuit that starts and controls the main burners. Shortly after the
main burners ignite, the indoor fan starts and circulates warm air through
your home, or building.
When the air temperature rises to the selected setting, the control deenergizes the heating electrical circuit which, in turn, extinguishes the main
burners. The indoor fan continues to circulate warm air until most of the
heat is removed from the unit’s combustion chamber.

Your unit is equipped with automatic reset safety limit controls to prevent
overheating. When one of these controls open, it shuts down the heating
electrical circuit until it cools down sufficiently. Inadequate airflow (i.e.,
caused by dirty air filters or a defective fan motor) may cause the unit to
cycle on and off as the limit controls trip and automatically reset. If you
suspect that the unit is cycling on its limit controls, immediately contact a
serviceman for instructions.

11

4. Remove the access panel that contains the following label:

6. Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!
Follow “What To Do If You Smell Gas” in the safety information above
in this manual. If you don’t smell gas, go to the next step.
7. Turn gas control knob counter-clockwise or flip the toggle switch to “ON”.
8. Replace panel removed in Step 4.
9. Turn on all electric power to the appliance.
10.Set the temperature control to desired setting.
Note: If the unit is equipped with modulating gas heat, the discharge air
setpoint will also need to be set before the initial setup is complete.
11. If the appliance does not operate, follow instructions in “To Turn Off Gas
To The Appliance” below and call your service technician or gas supplier.

To Turn Off Gas To The Appliance
REMOVE THIS PANEL
TO GAIN ACCESS

1. Set the temperature control to lowest setting.
2. Turn off all electric power to the appliance if service is to be performed.
3. Remove the access panel that contains the following label:

TO THE GAS VALVE
REMOVE THIS PANEL
5. Turn the gas control knob clockwise or flip the toggle switch to the “OFF”
position.
Note: Some valves require the knob to be pushed in slightly before turning.
Do not force.

TO GAIN ACCESS
TO THE GAS VALVE
4. Turn the gas control knob clockwise or flip the toggle switch to the “OFF”
position.
Note: Some valves require the knob to be pushed in slightly before turning.
Do not force.

The manufacturer optimizes the performance of homes and buildings around the world. A business of
Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments,
the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive
building services, and parts. For more information, visit www.IRCO.com.
The manufacturer has a policy of continuous product and product data improvement and reserves the right to change
design and specifications without notice
© 2012 Trane All rights reserved
RT-SVU04F-EN (11 May 2012)
Supersedes RT-SVU04E-EN (10 Nov
2011)

We are committed to using environmentally
conscious print practices that reduce waste.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : TCS - Clarksville
Create Date                     : 2006:01:12 09:15:33Z
Keywords                        : owner manual, RT-SVU04F-EN, Voyager, Voyager Light Commercial, Voyager Large Commercial
Marked                          : True
Modify Date                     : 2012:03:08 08:16:14Z
Subject                         : Packaged Rooftop Air Conditioners Voyager™ Gas/Electric For Servicers and Owners Use
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Creator Tool                    : FrameMaker 10.0.2
Producer                        : Acrobat Distiller 10.1.2 (Windows)
Format                          : application/pdf
Description                     : Packaged Rooftop Air Conditioners Voyager™ Gas/Electric For Servicers and Owners Use
Title                           : Owner Manual
Creator                         : TCS - Clarksville
Document ID                     : uuid:1aba2c2d-8162-4a83-9c10-f78518434445
Instance ID                     : uuid:1737c94d-0e3c-4e23-be40-163f50925048
Page Mode                       : UseOutlines
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu