Pub. No. 22-5128-02
69-1216
OWNER’S GUIDE
XT500C Deluxe Programmable
Heat Pump Thermostat
Pub. No. 22-5128-02
69-1216
2
Pub. No. 22-5128-02
69-1216
TABLE OF CONTENTS
CUSTOMIZING YOUR THERMOSTAT ............................................................................................................. 5
Program Options Set-Up by Your Trane Dealer ............................................................................................ 5-6
GETTING AROUND THE KEYBOARD ............................................................................................................. 7-8
Emergency Heat ........................................................................................................................................... 9
Auxiliary Heat ................................................................................................................................................ 9
FEATURES ........................................................................................................................................................ 10
FEATURES YOU’LL WANT TO KNOW MORE ABOUT................................................................................... 11
Comfort-R Comfort Enhancement System .................................................................................................... 11
Adaptive Intelligent Recovery Control ........................................................................................................... 12
The Optimum Comfort and Energy Savings Solution ............................................................................... 13
NEAT STUFF YOU’LL BE USING OFTEN ....................................................................................................... 15
Setting Temporary Temperatures .................................................................................................................. 15
Changing Temperature Setting Until the Next Schedule Period.................................................................... 15
Changing Temperature Setting Indefinitely ................................................................................................... 17
Vacation Mode............................................................................................................................................... 20
Information Key ............................................................................................................................................. 24
3
Pub. No. 22-5128-02
69-1216
Displaying Outdoor Temperature................................................................................................................... 24
Displaying Current Settings ........................................................................................................................... 25
Filter Indication .............................................................................................................................................. 26
Setting or Resetting Filter Indication Timer ................................................................................................... 26
PROGRAMMING YOUR THERMOSTAT .......................................................................................................... 29
Clock ............................................................................................................................................................. 29
Setting Current Day and Time ....................................................................................................................... 29
Setting System and Fan ................................................................................................................................ 32
Set System .................................................................................................................................................... 32
Set Fan .......................................................................................................................................................... 32
7-Day Program and Operation ...................................................................................................................... 33
7-Day Preprogrammed Schedule .................................................................................................................. 33
Customizing Your Own 7-Day Schedule ....................................................................................................... 35
Programming the First Day ........................................................................................................................... 39
Copying a Day ............................................................................................................................................... 44
Clearing Schedule Period ............................................................................................................................. 47
24-Hour Program and Operation ................................................................................................................... 50
24-Hour Preprogrammed Schedule .............................................................................................................. 50
Customizing Your Own 24-Hour Schedule .................................................................................................... 51
Programming Your 24-Hour Schedule .......................................................................................................... 52
Constant Temperature Setpoint Programming .............................................................................................. 57
Setting Temperature and Fan Operation ....................................................................................................... 57
4
Pub. No. 22-5128-02
69-1216
TROUBLESHOOTING....................................................................................................................................... 60
DEFINITIONS .................................................................................................................................................... 63
INDEX ................................................................................................................................................................ 66
LIMITED WARRANTY ....................................................................................................................................... 67
CUSTOMER ASSISTANCE ............................................................................................................................... 68
5
Pub. No. 22-5128-02
69-1216
CUSTOMIZING YOUR THERMOSTAT
Program Options Set-Up by Your Trane Dealer
Your Trane dealer has programmed your thermostat using the options checked below. For example, your
thermostat displays temperatures in degrees Fahrenheit if the checkbox next to Fahrenheit (
°
F) is checked.
Contact your Trane dealer to reprogram any of the options listed.
NOTE: If no options are checked, those listed in the first column are the factory settings on your thermostat.
Refer to the Definitions section for a description and comparison of Adaptive Intelligent Recovery Control (a
Honeywell trademark) to Conventional recovery.
6
Pub. No. 22-5128-02
69-1216
NOTE: The XT500C thermostat is manufactured for the Trane Company by Honeywell Inc. Specific features
are unique to Trane and are only available on Trane models.
Comfort-R™ Control
Off
On
Adaptive Intelligent
Recovery™ Control
On
Off (Conventional recovery)
Cooling Droop
On
Off
Temperature Display
Fahrenheit (°F)
Centigrade (°C)
Clock Format
12-Hour Clock Format
24-Hour Clock Format
System Setting
(Heating and Cooling
Setting)
Auto/Manual (System
automatically selects
Heat or Cool; You can
select Em. Heat, Heat,
Cool or Off.)
Manual Only (You
select Em. Heat, Heat,
Cool or Off.)
Auto only (System
automatically
selects Heating or
Cooling.)
Outdoor Temperature
Display
No outdoor
temperature is
displayed
Outdoor temperature
is displayed (requires
an outdoor sensor).
Programming
7-Day Programming
24-Hour Programming
Constant Temp-
erature Setpoint
Programming
7
Pub. No. 22-5128-02
69-1216
GETTING AROUND THE KEYBOARD
The keyboard is located behind the thermostat cover. Three frequently used keys are located next to the display
(Increase temperature setting, Decrease temperature setting, and Information key). The thermostat displays
important information such as day, time, schedule period, temperature, filter indicator, system and fan operation.
WHAT'S THE ROOM TEMPERATURE?
WHAT TIME IS IT?
WHAT DAY IS IT?
CURRENT PROGRAMMING
PERIOD (EXAMPLE
DISPLAY SHOWS "WAKE")
CURRENT SYSTEM
SETTING (EXAMPLE
DISPLAY SHOWS "HEAT")
CURRENT FAN
SETTING (EXAMPLE
DISPLAY SHOWS "AUTO")
DISPLAY IS BACKLIT
FOR EASY READABILITY
WHEN A KEY IS PRESSED.
DECREASE TEMPERATURE SETTING.
INCREASE TEMPERATURE SETTING.
INFORMATION AT YOUR FINGERTIPS!
DISPLAY THE OUTDOOR
TEMPERATURE (ON SOME MODELS),
CHECK YOUR CURRENT TEMPERATURE
SETTINGS, OR DISPLAY FILTER USE
IN NUMBER OF DAYS.
DAYLIGHT
SAVINGS TIME
INDICATOR
FILTER
EXPIRATION
INDICATOR
8
Pub. No. 22-5128-02
69-1216
M13301
Time Set Program
SystemFilter Fan
Run
Program
Hold Temp
Set Current
Day/Time Wake Leave Return Sleep
Day Heat/Cool
Settings
Daylight
Time Copy
NO NEED TO WORRY ABOUT
PRESSING THE WRONG KEY!
RUN PROGRAM, RETURN
TO NORMAL OPERATIONS,
OR UNDO LAST ACTION.
HOLD MODE: OVERRIDE
NORMAL PROGRAMMING
OPERATION, OR GO
INTO VACATION MODE!
SET CURRENT DAY AND TIME (INITIALLY
AND AFTER EXTENDED POWER OUTAGES).
SET CURRENT OR
PROGRAM DAY
EASILY CHANGE
BETWEEN STANDARD AND
DAYLIGHT SAVINGS TIME
EASY PROGRAMMING!
COPY ONE
PROGRAMMED DAY
TO ANOTHER DAY
SWITCH BETWEEN
HEATING AND COOLING
TEMPERATURE SETTINGS
PROGRAM SCHEDULING KEYS
PROGRAM UP TO FOUR TIME
PERIODS AND TEMPERATURES
FOR EACH DAY OF THE WEEK.
TIME KEYS
INCREASE OR
DECREASE TIME
SETTING FOR
CURRENT OR
PROGRAMMED
TIMES.
SELECT SYSTEM OPERATION
(EM. HEAT, HEAT, COOL, OFF, AUTO).
NO MORE GUESSING! SELECT
FILTER EXPIRATION TO REMIND
YOU TO CHANGE THE FILTER.
CHOOSE FAN OPERATION (ON OR
AUTO), OR CHOOSE FAN OPERATION
FOR EACH PROGRAM PERIOD OF
THE DAY ON SELECT MODELS.
Time
M17032
Set Program
Wake Leave Return Sleep
SET WAKE TIMES
AND TEMPERATURES
SET LEAVE TIMES
AND TEMPERATURES
SET RETURN TIMES
AND TEMPERATURES
SET SLEEP TIMES
AND TEMPERATURES
9
Pub. No. 22-5128-02
69-1216
Emergency Heat
The Emergency Heat feature allows you to “turn on”
the electric heat section of the system by moving the
system switch to the Em. Ht. position. The LED lights
and the thermostat displays “Em. Ht.” when the
system calls for emergency heating. The thermostat
may also display “Aux. Ht.” if the system calls for
additional back-up heating (see figure to right).
When the heat pump requires servicing, the LED
lights and the system automatically activates emer-
gency heat. After contacting your service technician,
clear the LED signal by moving the system switch to
Em. Ht. then back to Heat or Auto.
Auxiliary Heat
The auxiliary heaters assist the heat pump under
normal conditions when low outdoor temperature
occurs. The auxiliary heaters may also operate while
in the recovery mode to maintain comfort level. The
thermostat displays “Aux. Ht. ” (see figure above)
when the auxiliary heating equipment operates.
Aux Ht
System
M13302
Em Heat
Em Ht
EM HT DISPLAYS WHEN SYSTEM CALLS FOR
HEAT IN EMERGENCY HEAT MODE.
EM HT DISPLAYS WHEN SYSTEM SWITCH
IS IN EMERGENCY HEAT POSITION.
AUX HT DISPLAYS WHEN SYSTEM CALLS FOR
ADDITIONAL BACK-UP HEATING DURING NORMAL
CONDITIONS
OR
IN EMERGENCY HEAT MODE.
FLAME DISPLAYS DURING CALL FOR HEAT.
10
Pub. No. 22-5128-02
69-1216
FEATURES
Worry-free programming.
Comfort-R Comfort Enhancement Process—a
unique Trane feature.
Adaptive Intelligent Recovery Control for
comfort and energy savings.
Wake, Leave, Return and Sleep at the comfort
level you select.
Customize the program schedule—program
your own schedule to fit your needs.
Continuous comfort and energy savings—
adjust the schedule as often as you like.
Temporary schedule override—set the
thermostat higher or lower for the current
program schedule.
Vacation mode (1 to 255 days) for added
comfort and energy savings. Set the
temperature higher or lower for energy savings
while on vacation. At the same time, set the
comfort level you want when you return.
Permanent schedule override—set the
thermostat higher or lower indefinitely.
Set the filter indicator (0, 7, 14, 21, 30, 45, 60,
90, 120, 180, 270, or 360 days) to remind you to
change the filter.
Information at the press of a button—use the
Information Key to find out the outdoor
temperature (optional accessory), the current
setpoints, or the filter status.
No batteries needed—your thermostat retains
the schedule for the life of the product. You
never have to reprogram the schedule even
after a power outage. (The day and time may
need to be reset after an extended power
outage.)
Set or reset the day and time as needed—you
can even set Daylight Savings Time.
11
Pub. No. 22-5128-02
69-1216
FEATURES YOU’LL WANT TO
KNOW MORE ABOUT
Comfort-R Comfort Enhancement System
Comfort can best be described as the proper balance
of temperature and relative humidity, also known as
“your comfort index.” The greatest level of comfort is
achieved when the temperature and relative humidity
are in balance with your body. When the relative
humidity is low, you feel comfortable at a higher
temperature. Likewise, when the relative humidity is
high, you feel comfortable only at a lower tempera-
ture. However, if the relative humidity becomes too
high, then true comfort cannot be achieved at any
temperature.
The Comfort-R™ system is specifically designed to
enhance the moisture removal process of your air
conditioning system and to make the air drier. This
system is so unique, it received a patent from the U.S.
Patent Office. During times of high relative humidity,
as well as during mild weather, the Comfort-R system
increases the moisture removal ability of your air-
conditioning system. This results in a lower relative
humidity inside your home, which in turn, allows you
to feel more comfortable. The resulting lower relative
humidity also allows you to maintain the temperature
setting on your thermostat at a higher temperature.
12
Pub. No. 22-5128-02
69-1216
Adaptive Intelligent Recovery Control
Your Thermostat Senses Temperature
More Like You Do
Your new thermostat is so smart, it’s almost human. You
perceive temperature from a variety of sources, not only
from the air in the room, but also from your surrounding
walls, windows and furnishings. Humans feel differences
in temperature as slight as two degrees Fahrenheit.
Common household thermometers and standard
thermostats sense only air temperature, which may not
reflect how hot or cold the room actually feels to you.
Your new thermostat reads both the temperature of the
wall and the air, and responds to temperature changes
as little as one degree Fahrenheit, so room temperature
is more likely to feel right to you and your family.
The Deluxe Programmable Heat Pump Thermostat acts
like a computer. When calculating the time to turn on
your heating or cooling system, it considers (1) air
temperature, (2) wall temperature, and (3) the time you
want to reach the comfort temperature. After considering
these three things, Adaptive Intelligent Recovery™
control gradually changes the temperature from the
energy savings setting to the comfort setting (for
example, from a heating temperature of 62° at night to
70° in the morning).
The system runs continuously until the comfort tempera-
ture you choose is reached without overshooting the
setting. This saves energy. How do you know when the
system is in recovery? The thermostat displays In
Recovery whenever the thermostat activates Adaptive
Intelligent Recovery Control. So, In Recovery displays
during the recovery time from Sleep to Wake and from
Leave to Return.
M10344
Auto
System Fan
Mon In
Room
AM
Recovery
Sleep
Heat
In Recovery indication shown in example above.
13
Pub. No. 22-5128-02
69-1216
After installation or new schedule programming, your
thermostat learns from experience. How? Each day it
checks how closely it hit the recovery target (for
example, 70° at 6:00 AM) and adjusts the next day’s
recovery start time accordingly. After four to eight
days, the thermostat has adjusted to local weather,
your lifestyle, the construction of your home, and your
heating and cooling system.
The Optimum Comfort and
Energy Savings Solution
In this example, Adaptive Intelligent Recovery Control
starts to recover at 4:00 AM and reaches the comfort
temperature of 68° at 7:00 AM. Recovery time varies
with the starting temperature and the comfort tem-
perature you choose.
Your new thermostat saves energy and keeps you
comfortable at the same time. By now you may be
wondering how to program your thermostat and how
to use some more time and energy-saving features.
First, let’s look at features you’ll be using often, like
how to override the current programming mode or
hold the thermostat at a specific temperature while
you go on vacation. You can even program the
thermostat to return to normal scheduled program-
ming on your last day of vacation so you don’t have to
worry about energy saving while you are gone or not
being comfortable when you return.
14
Pub. No. 22-5128-02
69-1216
AM
PM
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON
WAKE LEAVE RETURN NIGHT TEMPORARY UNOCCUIPIED
SET
PT
AM
PM
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON
WAKE LEAVE RETURN NIGHT TEMPORARY UNOCCUIPIED
SET
PT
AM
PM
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON
WAKE LEAVE RETURN NIGHT TEMPORARY UNOCCUIPIED
SET
PT
AM
PM
SUN MON TUE WED THU FRI SAT COOL ON HEAT ON
MORNING LEAVE RETURN SLEEP TEMPORARY UNOCCUIPIED
SET
PT
At 4:00 AM
Recovery Begins
At 5:00 AM
Recovery
Continues
At 6:00 AM
Recovery
Continues
At 7:00 AM System
Operating in Comfort Mode
ENERGY
SAVINGS
PERIOD
RECOVERY FROM ENERGY SAVINGS COMFORT
PERIOD
TIME
TEMPERATURE
THE THERMOSTAT USES THE SAME SCHEME TO RETURN GRADUALLY
TO LOWER COMFORT TEMPERATURE DURING THE COOLING SEASON.
M17033
15
Pub. No. 22-5128-02
69-1216
NEAT STUFF YOU’LL BE USING OFTEN
Setting Temporary Temperatures
If your thermostat is set for 7-Day or 24-Hour Operation, you can override the current schedule period and
change the temperature setting until the next schedule period, or change the temperature setting while you are
on vacation. You can also change the temperature setting indefinitely.
Changing Temperature Setting Until the Next Schedule Period
NOTE: This feature does not apply to Constant Temperature Setpoint Programming.
M17035
Temporary Setting
Press Increase or Decrease until the desired
temperature setpoint displays.
While selecting a temporary setting, only the setpoint displays.
16
Pub. No. 22-5128-02
69-1216
The temporary temperature setting you select displays for approximately 3 seconds. The display reads
Temporary until the next period begins, or you cancel the Hold.
IMPORTANT
To cancel the Hold before the designated
time, press Run Program.
After selecting a temporary setting, display reads Temporary until canceled.
Example displays shows temporary heat setting of 70° at 6:00 AM.
Run
Program
M12984
Auto
Fan
Mon
AM
Temporary
Heat
System
Heat
NOTE: If “” or “” appears under the temperature display, it means that both the heating and cooling
setpoints are being adjusted. Tapping the key changes both the heat and cool setpoints by one degree.
Press after the desired setpoint is reached to verify the setpoints.
NOTE: While in temporary operation, the thermostat uses conventional recovery for that period only. The
thermostat assumes you desire to maintain the temporary setting until the end of the period.
17
Pub. No. 22-5128-02
69-1216
Changing Temperature Setting Indefinitely
NOTE: This feature does not apply to Constant Temperature Setpoint Programming.
NOTE: The current time does not display while in this mode.
Hold Temp
1. Press Hold Temp once.
Pressing Hold Temp once displays the thermostat in Hold mode.
Example display shows temporary heat setting of 60°.
M17040
Auto
Fan
Heat
Setting
System
Heat
18
Pub. No. 22-5128-02
69-1216
2. Press Increase or Decrease to
change the temperature setpoint, if desired.
M17041
Auto
Fan
Heat
Setting
System
Heat
By pressing the Temperature keys, you can select a temporary temperature.
This temperature setting remains until the hold is canceled.
Example displays shows heat set to 61°.
3. Press Heat/Cool Settings to change
between heat and cool settings.
Heat/Cool
Settings
M17042
Auto
Fan
Cool
Setting
System
Heat
Pressing Heat/Cool Settings displays the other temperature setpoint.
Example displays shows temporary cooling setting of 78°.
19
Pub. No. 22-5128-02
69-1216
4. Press Increase or Decrease to adjust
temperature settings.
M17043
Auto
Fan
Cool
Setting
System
Heat
Pressing the Temperature keys changes the temporary temperature.
Example displays shows temporary cooling setting of 80°.
NOTE: The display changes from the setpoint to the room temperature after approximately 3 seconds.
IMPORTANT
To cancel the Hold, press Run Program.
Run
Program
20
Pub. No. 22-5128-02
69-1216
Vacation Mode
NOTE: This feature does not apply to Constant Temperature Setpoint Programming.
1. Press Hold Temp twice.
Pressing Hold Temp twice displays the thermostat in Vacation mode.
Example displays shows temporary heat setting of 60°.
M17036
Auto
Fan
HeatDaysMon
Wake
Hold for
Setting
System
Heat
Hold Temp
21
Pub. No. 22-5128-02
69-1216
Time
M17037
Auto
Fan
HeatFri Days
Wake
Hold for
Setting
System
Heat
LeaveWake Return Sleep
2. Press Time or Time until the desired
number of days displays (1 to 255 days).
By pressing the Time keys, the number of vacation days is selected.
Example displays shows 18 vacation days.
M17038
Auto
Fan
HeatDaysFri
Hold for
Setting
System
Heat
Return
3. Press Wake, Leave, Return or Sleep to select the
period the Hold will stop.
In this example, the Hold will stop after the 18th day
at the beginning of the Return period.
22
Pub. No. 22-5128-02
69-1216
4. Press Increase or Decrease to adjust
the temperature setting, if desired.
M17039
Auto
Fan
HeatDaysFri
Hold for
Setting
System
Heat
Return
By pressing Temperature keys, a new hold temperature is selected.
Example display shows temporary heat setting of 55°.
NOTE: Only the heating temperature is used when the System is set to Heat. Similarly, only the cooling
temperature is used when the System is set to Cool. The thermostat uses both the heating and
cooling temperatures when the System is set to Auto.
5. Press Heat/Cool Settings to change between heat and cool settings.
6. Press Increase or Decrease to adjust the temperature setting, if desired.
(Example: Cool 84° = cooling equipment operates when the room temperature is
above 84°F)
Heat/Cool
Settings
23
Pub. No. 22-5128-02
69-1216
IMPORTANT
To cancel the Hold before the designated time, press Run Program.
Run
Program
Pressed the wrong key?
Want to start over?
Don’t worry! You can always press
to return display to normal.
Run
Program
24
Pub. No. 22-5128-02
69-1216
Information Key
The Information key provides information at your
fingertips. The sequence of key presses is as follows:
Outdoor Temperature (if equipped)
Current Setpoint of Mode in Use (Heat or Cool)
Setpoint of Mode Not Currently in Use
Filter Status
M17044
INFORMATION KEY
If the filter status is expired (refer to Filter Indication section), the sequence of key presses is as follows:
Filter Status
Outdoor Temperature (if equipped)
Current Setpoint of Mode in Use (Heat or Cool)
Setpoint of Mode Not Currently in Use
M17045
Outdoor
Displaying Outdoor Temperature
Press once to display the outdoor
temperature (if equipped).
NOTE: If the filter status is expired, press
twice to display outdoor temperature.
Pressing key once displays the outdoor temperature.
Example displays shows outdoor temperature at 50°.
25
Pub. No. 22-5128-02
69-1216
Displaying Current Settings
Press twice to check the current
temperature setpoint. Press three times
to check the temperature setpoint of the
mode not currently in use.
NOTE: Without outdoor temp. sensor, press once
to display current setpoint; twice for opposite
setpoint.
NOTE: If the filter status is expired, press three
times to check current temperature setpoint,
if equipped w/outdoor sensor.
M17046
Cool
Pressing key twice displays current setpoint.
Example displays shows cooling setpoint of 75°.
26
Pub. No. 22-5128-02
69-1216
M17047
FILTER EXPIRATION INDICATOR
Filter Indication
Your thermostat monitors the time the fan is running
and lets you know when to replace the filter, based on
the number of fan run-time days you select. Upon
expiration, the thermostat displays Filter and the
backlight flashes during the Wake and Return modes.
To temporarily cancel the flashing
display, press␣␣␣␣␣␣
27
Pub. No. 22-5128-02
69-1216
Setting or Resetting Filter Indication Timer
Your thermostat comes preset to the 30-day setting. To change this setting, or reset after filter expiration, follow
these instructions:
1. Press Filter to enter the Filter mode.
Filter
M17048
Filter
Days
Setting
Pressing the Filter key displays filter information.
In this example, current fan run time is 5 days and the filter is set to expire in 30 days.
2. Press and hold Filter for at least
3 seconds to reset fan run time to
zero.
M17049
Filter
Days
Setting
Holding down the Filter key resets counter to “0” days.
Filter
28
Pub. No. 22-5128-02
69-1216
3. Press Time or Time until the desired number of days displays (0, 7, 14, 21, 30, 45, 60, 90,
120, 180, 270, or 360).
4. Press Run Program to return to normal operation.
IMPORTANT
To track the time the fan is running, you must select a setting other than 0. If the setting is
0 days, the display will always show “0 Days; 0 Setting” when Filter is pressed.
Run
Program
29
Pub. No. 22-5128-02
69-1216
PROGRAMMING YOUR THERMOSTAT
Clock
Setting Current Day and Time
IMPORTANT
Always press the keys with your fingertip or similar blunt tool. Sharp instruments like pens and pencil
points will damage the keyboard.
M12950
Mon
PM
Set Day/Time
Auto
System Fan
Auto Wait
Room
On initial power up or after an extended power loss,
1:00 PM flashes on the display until a key is pressed.
Pressed the wrong key?
Want to start over?
Don’t worry! You can always press
to return display to normal.
Run
Program
30
Pub. No. 22-5128-02
69-1216
1. Press Set Current Day/Time.
M17050
PM
Mon
Set Day/Time
Set Current
Day/Time
Pressing Set Current Day/Time displays the information shown.
2. Press Day until the current day displays.
NOTE: Mon = Monday, Tue = Tuesday,
Wed = Wednesday,
Thu = Thursday, Fri = Friday,
Sat = Saturday, Sun = Sunday.
M17051
PM
Tue
Set Day/Time
Day
By Pressing Day, you can set the current day.
Example display shows Tuesday.
31
Pub. No. 22-5128-02
69-1216
3. Press Time or Time until the
current time displays.
NOTE: Tapping Set Current Day/
Time advances the time in
one-hour increments.
M17052
AM
Tue
Set Day/Time
By Pressing Time, you can set the current time.
Example display shows 8:15 AM.
Time
NOTE: If the current time is Daylight
Savings Time, press
Daylight Time until DST
displays.
Run
Program
Daylight
Time
M17053
AM
Tue
Set Day/Time
By Pressing Daylight Time, you can set Daylight Savings Time.
4. Press Run Program to return to normal operation.
32
Pub. No. 22-5128-02
69-1216
Setting System and Fan
The system default setting is Heat and the fan default setting is Auto. Use the System and Fan keys to change the
settings. The fan settings can be set for each schedule period individually. The system selection is for all the
schedule periods.
Set System
Press System until the desired system displays (Em.
Heat, Heat, Off, Cool, or Auto).
Em. Heat: The thermostat controls only the backup
heat. The heat pump is off.
Heat: The thermostat controls the heating.
Off: Both the heating and cooling are off.
Cool: The thermostat controls the cooling.
Auto: The thermostat automatically changes
between heating and cooling operation, depend-
ing on the indoor temperature.
M17055
Auto
Fan On
System
Fan
Set Fan
Press Fan until the desired mode displays (On or Auto).
On: Fan operates continuously.
Auto: Fan operates only when heating or cooling.
M13303
System
Heat
Off Auto
Cool
Em Heat
33
Pub. No. 22-5128-02
69-1216
7-Day Program and Operation
Your thermostat comes preset for 7-Day Operation unless otherwise noted on page 6. After reviewing the options
following this section, you may find that 24-Hour Operation or Constant Temperature Setpoint Programming is
better for you and your family. If so, please consult your Trane dealer or service technician.
M12958
Auto
Fan
Mon
AM
Wake
Set Program
Setting
Heat
During 7-Day Operation, one day of the week displays in program mode
(Monday is shown in the example).
7-Day Preprogrammed Schedule
If your thermostat is set for 7-Day Operation, follow the steps below. Otherwise, refer to 24-Hour Program and
Operation, or Constant Temperature Setpoint Programming.
The preprogrammed schedule is shown in Table 1 (same schedule for all days of the week). You may keep this
schedule or organize your own.
During 7-Day Operation, you can set your thermostat for
four periods (Wake, Leave, Return and Sleep) and up to
eight temperatures (four Heat and four Cool) for each day
of the week. Each day can be the same or different.
34
Pub. No. 22-5128-02
69-1216
Table 1. 7-Day Preprogrammed Schedule.
WAKE LEAVE RETURN SLEEP
SUNDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
MONDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
TUESDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
WEDNESDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
THURSDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
FRIDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
SATURDAY TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
35
Pub. No. 22-5128-02
69-1216
Customizing Your Own 7-Day Schedule
Before starting the programming procedure, use Tables 2 and 3 to organize your schedule. The preprogrammed
schedule is shown in Table 1. Four time periods are available for each day of the week – WAKE, LEAVE,
RETURN, and SLEEP.
A Word About Power Outages
Don’t worry! Your thermostat retains the schedule (preprogrammed or your own) for the life of the product.
The clock and day information is retained for a minimum of ten minutes during a power outage. After a
longer power outage, the current time and day may need to be set (1:00 PM flashes on the display), but
the schedule is retained.
36
Pub. No. 22-5128-02
69-1216
Instructions
1. Write in the time you want each schedule period to begin.
2. Write in the heating temperature (H) and cooling temperature (C) you want for each period.
3. Circle the fan operation you desire for each period.
4. Begin with Programming the First Day!
Pressed the wrong key?
Want to start over?
Don’t worry! You can always press
to return display to normal.
Run
Program
37
Pub. No. 22-5128-02
69-1216
Table 2. Your 7-Day Schedule.
WAKE LEAVE RETURN SLEEP
SUNDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
MONDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TUESDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
WEDNESDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
THURSDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
FRIDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
SATURDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
38
Pub. No. 22-5128-02
69-1216
Table 3. An Extra 7-Day Schedule.
WAKE LEAVE RETURN SLEEP
SUNDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
MONDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TUESDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
WEDNESDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
THURSDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
FRIDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
SATURDAY TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
39
Pub. No. 22-5128-02
69-1216
Programming the First Day
To modify the preprogrammed schedule, start by programming the Wake time and temperature and fan operation
for any one day:
NOTE: This schedule follows the current day and time you set in the section Setting Current Day and Time and
the Heat or Cool setting and Fan setting you selected in the section Setting System and Fan.
1. Press Wake.
Wake
By pressing Wake, you enter the program mode.
Example display shows 6:00 AM on Tuesday with Heat set to 70°F.
M17056
Heat
Auto
Fan
Wake
AM
Tue
Set Program
Setting
40
Pub. No. 22-5128-02
69-1216
2. Press Day until the desired day
displays.
Day
M17057
Heat
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Day, you select the day to program.
Example display shows Monday is selected and ready to program.
3. Press Time or Time until the
desired Wake time displays.
NOTE: The program times are in
fifteen-minute intervals.
(Example: 8:00, 8:15, 8:30).
Time
M17058
Heat
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Time, you select the time the Wake period will begin.
Example display shows the Wake period will begin at 6:30 AM.
41
Pub. No. 22-5128-02
69-1216
4. Press Increase or Decrease until
the desired Wake temperature displays.
NOTE: The setpoint temperature range
is 55 to 85°F (13 to 29°C) for
heating and 65 to 99°F (18 to
37°C) for cooling.
M17059
Heat
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Increase s or Decrease t, you select the temperature for the Wake period.
Example display shows the heating Wake period set for 68°.
NOTE: Press Fan to modify fan operation. Auto means the fan runs only when the heating or
cooling equipment is operating. On means the fan runs continuously for the entire
schedule period.
Fan
42
Pub. No. 22-5128-02
69-1216
5. Press Heat/Cool Settings to make selec-
tions for the opposite system setting (either
Heat or Cool).
NOTE: If your system is set for Heat, only
the heating temperature will be used.
Similarly, if your system is set for
Cool, only the cooling temperature
will be used. If your system is set for
Auto, either the heating or cooling
temperature may be used depending
on the temperature of the room.
Heat/Cool
Settings
M17060
Cool
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Heat/Cool Settings, you select the cooling system
(if you already set the heating temperature). The current setting
displays. Example display shows the cooling system was
previously set for 78°.
6. Press Increase or Decrease until
the desired temperature setpoint
displays.
M17061
Cool
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Increase or Decrease , you select the
cooling Wake temperature.Example display shows the
cooling Wake period set for 76°.
43
Pub. No. 22-5128-02
69-1216
Leave Return Sleep
Run
Program
7. Press Leave, Return or Sleep and repeat steps 3, 4, 5 and 6 for programming the rest of the
day. The day is now programmed (first day of a seven-day schedule).
IMPORTANT
Repeat steps 1 through 7 for each day of the week that has a different schedule from the
first day. Or, refer to the section Copying a Day to copy any programmed day to another.
8. Press Run Program to return to normal operation.
Pressed the wrong key?
Want to start over?
Don’t worry! You can always press
to return display to normal.
Run
Program
44
Pub. No. 22-5128-02
69-1216
Copying a Day
NOTE: The copy feature applies only to 7-Day Operation. The thermostat must be in the program mode to use
the copy feature. Go to step 2 if the thermostat is already in the program mode (Set Program displays in
upper left corner).
1. Press Wake, Leave, Return or Sleep to enter
program mode.
Leave Return SleepWake
2. Press Day to select the day to copy from.
Day
M17062
Heat
Auto
Fan
Wake
AM
Mon
Set Program
Setting
By pressing Day, you select which day’s schedule to copy.
Example display shows the thermostat in program mode with
Monday ready to be copied.
45
Pub. No. 22-5128-02
69-1216
3. Press Copy.
Copy
M17063
Mon
By pressing Copy, you copy a day’s schedule into memory.
Example display shows Monday’s schedule has been copied into memory.
4. Press Day until the day to be copied to is
displayed.
Day
M17064
Mon Wed
By pressing Day again, you select which day to copy to. Example display shows Monday and Wednesday.
Since Monday was already selected, Monday’s schedule will be copied to Wednesday.
46
Pub. No. 22-5128-02
69-1216
5. Press Copy.
NOTE: donE displays for two seconds
before the normal display
returns.
Run
Program
Copy
M17065
By pressing Copy again, you complete the copy command. Example display shows donE. Monday’s schedule
was successfully copied to Wednesday (Monday and Wednesday now have the same schedule).
6. Repeat steps as necessary for all the periods and days desired.
7. Press Run Program to return to normal operation.
47
Pub. No. 22-5128-02
69-1216
Clearing Schedule Period
Suppose you want to skip a schedule period or periods for a particular day because you don’t need them. For
example, if Saturday is a day you normally stay at home from school or work, you can clear the Leave and
Return periods for this day and keep the Wake and Sleep periods. You can always reprogram the periods later.
NOTE: The clear feature applies to 7-Day and 24-Hour Operation. The thermostat must be in the program
mode to use the clear feature. Go to step 2 if the thermostat is already in the program mode (Set
Program displays in upper left corner).
1. Press Leave, Return or Sleep to
enter program mode.
Leave Return Sleep
M17066
Heat
Auto
Fan
Leave
AM
Mon
Set Program
Setting
By pressing Leave, Return, or Sleep, you enter the program mode.
Example display shows 8:00 AM on Monday in the Leave period, with Heat set for 62°
48
Pub. No. 22-5128-02
69-1216
2. For 7-Day Operation, press Day until the
desired day displays. For 24-Hour
Operation, skip to step 3.
Day
M17067
Heat
Auto
Fan
Leave
AM
Sat
Set Program
Setting
Press Day to select which day to begin clearing periods.
Example display shows Saturday is selected
3. Press and hold Leave, Return or Sleep
until the start time and temperature
setting are cleared (approximately
3 seconds).
Leave Return Sleep
M17068
Leave Sat
Set Program
NOTE: Wake cannot be cleared. By pressing and holding Leave, Return or Sleep, the period for that
day is cleared. Example display shows Saturday’s Leave period has
been cleared.
49
Pub. No. 22-5128-02
69-1216
You do not have to program a replacement time for the remaining periods, for example Wake and Sleep. If you
cleared only the Leave and Return periods for Saturday (or any day), the thermostat remains in the Wake period
for all of Saturday until the Sleep period.
4. Repeat steps as necessary for all the periods to be cleared.
5. Press Run Program to return to normal operation.
Run
Program
50
Pub. No. 22-5128-02
69-1216
24-Hour Program and Operation
24-Hour Operation is the same as 7-Day Operation except
the same program repeats itself each day. Monday
through Sunday follows the same exact schedule
(four periods and up to eight temperatures).
M12959
Auto
Fan
Mon
AM
Wake
Set Program
Setting
Heat
TueWedThuFriSatSun
During 24-Hour Operation, all days of the week display in program mode.
24-Hour Preprogrammed Schedule
If your thermostat is set for 24-Hour Operation, follow the steps below. Otherwise, refer to 7-Day Program and
Operation, or Constant Temperature Setpoint Programming.
51
Pub. No. 22-5128-02
69-1216
The preprogrammed schedule is as follows (same schedule for all days of the week): You may keep this
schedule or organize your own.
Table 4. 24-Hour Preprogrammed Schedule.
Customizing Your Own 24-Hour Schedule
Before starting the programming procedure, use Tables 5 and 6 to organize your schedule. The preprogrammed
schedule is shown in Table 4. Four time periods are available—WAKE, LEAVE, RETURN, and SLEEP.
Table 5. Your 24-Hour Schedule.
WAKE LEAVE RETURN SLEEP
Program
Repeats
Every 24
Hours
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
WAKE LEAVE RETURN SLEEP
Program Repeats
Every 24 Hours TIME 6:00 AM
FAN AUTO
H 70 C 78
TIME 8:00 AM
FAN AUTO
H 62 C 85
TIME 5:00 PM
FAN AUTO
H 70 C 78
TIME 10:00 PM
FAN AUTO
H 62 C 75
52
Pub. No. 22-5128-02
69-1216
Instructions
1. Write in the time you want each schedule period to begin.
2. Write in the heating temperature (H) and cooling temperature (C) you want for each period.
3. Circle the fan operation you desire for each period.
4. Begin programming.
Table 6. An Extra 24-Hour Schedule.
WAKE LEAVE RETURN SLEEP
Program
Repeats
Every 24
Hours
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
TIME
FAN AUTO ON
H C
Programming Your 24-Hour Schedule
To program the Wake time and temperature and fan operation:
NOTE: This schedule follows the current day and time you set in the section Setting Current Day and Time and
the Heat or Cool setting and Fan setting you selected in the section Setting System and Fan.
53
Pub. No. 22-5128-02
69-1216
1. Press Wake.
Time
Wake
M17069
Heat
Auto
Fan
Wake
AM
MonTueWedThuFriSat Sun
Set Program
Setting
By pressing Wake, you enter the program mode.
Example display shows 6:00 AM with Heat set to 70°F.
2. Press Time or Time until the
desired Wake time displays.
NOTE: The program times are in
fifteen minute intervals.
(Example: 8:00, 8:15, 8:30).
M17070
Heat
Auto
Fan
Wake
AM
MonTueWedThuFriSatSun
Set Program
Setting
By pressing Time, you select the time the Wake period will begin.
Example display shows the Wake period will begin at 6:30 AM.
54
Pub. No. 22-5128-02
69-1216
3. Press Increase or Decrease until
the desired Wake temperature displays.
NOTE: The setpoint temperature range
is 55 to 85°F (13 to 29°C) for
heating and 65 to 99°F (18 to
37°C) for cooling.
By pressing Increase or Decrease , you select the temperature for the
Wake period. Example display shows the heating Wake period set for 68°.
NOTE: Press Fan to modify fan operation. Auto means the fan runs only when the heating or
cooling equipment is operating. On means the fan runs continuously for the entire
schedule period.
Fan
M17071
Heat
Auto
Fan
Wake
AM
MonTueWedThuFriSatSun
Set Program
Setting
55
Pub. No. 22-5128-02
69-1216
Heat/Cool
Settings
4. Press Heat/Cool Settings to make
selections for the opposite system
setting (either Heat or Cool).
NOTE: If your system is set for
Heat, only the heating
temperature will be used.
Similarly, if your system is
set for Cool, only the cooling
temperature will be used. If
your system is set for Auto,
either the heating or cooling
temperature may be used
depending on the tempera-
ture of the room.
By pressing Heat/Cool Settings, you select the cooling system (if you
already set the heating temperature). The current setting displays.
Example display shows the cooling system was previously set for 78°.
M17072
Cool
Auto
Fan
Wake
AM
MonTueWedThuFriSatSun
Set Program
Setting
56
Pub. No. 22-5128-02
69-1216
5. Press Increase or Decrease
until the desired temperature setpoint
displays.
By pressing Increase or Decrease , you select the cooling Wake temperature.
Example display shows the cooling Wake period set for 76°.
6. Press Leave, Return or Sleep and repeat steps 2, 3, 4, and 5 for programming the rest of the
day. The week is now programmed.
Leave Return Sleep
7. Press Run Program to return to normal operation.
Run
Program
M17073
Cool
Auto
Fan
Wake
AM
MonTueWedThuFriSatSun
Set Program
Setting
57
Pub. No. 22-5128-02
69-1216
Constant Temperature
Setpoint Programming
Unlike the first two options, Constant Temperature
Setpoint Programming does not have the Wake, Leave,
Return and Sleep periods. The temperature is set by
pressing the and keys.
M12960
Auto
Fan
Mon
AM
Set Program
Setting
Heat
System
Heat
The four periods (for example, Wake) are absent from the display in this mode.
Setting Temperature and Fan Operation
If your thermostat is set for Constant Temperature Setpoint Programming, follow the steps below. Otherwise,
refer to 7-Day Program and Operation, or 24-Hour Program and Operation.
To set the temperature and fan operation:
NOTE: Refer to the section Setting Current Day and Time to set the current day and time, and the section
Setting System and Fan to set the system and fan.
58
Pub. No. 22-5128-02
69-1216
1. Press Increase or Decrease until
the desired temperature displays.
NOTE: The setpoint temperature range
is 55 to 85°F (13 to 29°C) for
heating and 65 to 99°F (18 to
37°C) for cooling.
Fan
M17119
Heat
Setting
By pressing Increase or Decrease , you select the heating
temperature. Example display shows Heat is set for 68°.
NOTE: Press Fan to modify fan operation. Auto means the fan runs only when the heating or
cooling equipment is operating. On means the fan runs continuously for the entire
schedule period.
2. Press Information key to make selections for the opposite system setting (works like the
Heat/Cool Settings key).
59
Pub. No. 22-5128-02
69-1216
3. Press Increase or Decrease
until the desired temperature setpoint
displays.
By pressing Increase or Decrease after pressing
the cooling temperature. Example display shows Coo
NOTICE: This equipment is a Class B digital apparatus, which complies with Canadian Radio Interference
Regulations, CRC c. 1374.
CAUTION
Equipment Damage Hazard.
Can cause permanent damage to the compressor or other equipment.
To avoid possible equipment damage, do not operate cooling when outside temperature is below 50°F
(10°C). See equipment manufacturer instructions. To avoid possible compressor damage, allow the
compressor to remain off for five minutes before restarting.
M17075
Cool
Setting
60
Pub. No. 22-5128-02
69-1216
TROUBLESHOOTING GUIDE
(continued)
Symptom Possible Cause Action
Display does not come
on. Thermostat is not being
powered. Check if the thermostat is mounted and latched on the
wallplate—mount and latch the thermostat on the
wallplate.
Check if the circuit breaker is tripped—reset the circuit
breaker.
Check if the fuse is blown—replace the fuse.
Check if the system switch at the equipment is in the Off
position—set to the On position.
Check wiring between thermostat and HVAC equipment—
replace any broken wires.
If 24 Vac is present, proceed with troubleshooting.
Temperature setting
does not change
(Example: cannot set the
heating higher or the
cooling lower).
The upper or lower temperature
limits were reached. Check that the temperature setpoints are:
Heating: 55 to 85°F (13 to 29°C)
Cooling: 65 to 99°F (18 to 37°C).
61
Pub. No. 22-5128-02
69-1216
Troubleshooting Guide (continued).
(continued)
Symptom Possible Cause Action
Heating does not come
on. No power to the thermostat.
System selection is not set to Heat.
Heating setpoint is below room
temperature.
Check that setpoint is above room temperature.
Check if the circuit breaker is tripped—reset the circuit
breaker.
Check if the fuse is blown—replace the fuse.
Check if the system switch at the equipment is in the Off
position—set to On position.
If 24 Vac is present, proceed with troubleshooting.
Wait five minutes for the system to respond (thermostat
displays Wait).
Set system selection to Heat.
Cooling does not come
on. No power to the thermostat.
System selection is not set to Cool.
Cooling setpoint is above room
temperature.
Check that setpoint is below room temperature.
Check if the circuit breaker is tripped—reset the circuit
breaker.
Check if the fuse is blown—replace the fuse.
Check if the system switch at the equipment is in the Off
position—set to On position.
If 24 Vac is present, proceed with troubleshooting.
Wait five minutes for the system to respond (thermostat
displays Wait).
Set system selection to Cool.
62
Pub. No. 22-5128-02
69-1216
Troubleshooting Guide (continued).
Symptom Possible Cause Action
System on indicator
(flame=heat, snowflake=
cool) is lit, but no warm or
cool air is coming from
the registers.
Heating/cooling equipment turns on
the fan when the equipment has
reached the setpoint.
Wait a minute after seeing the flame or snowflake and then
check the registers.
System on indicator
reads Filter and backlight
is flashing.
Filter expired. Refer to the Filter Indication section.
Outdoor temperature not
displayed or is incorrect. Filter expired. Press twice for outdoor temperature when filter
expiration shows on display.
Refer to the Filter Indication section.
Installer did not activate this option.
Outdoor sensor is connected
incorrectly.
Contact installer or service technician.
LED is lit. System switch is set to Em. Heat. Move switch to Heat or Auto
Compressor failure. Contact service technician.
63
Pub. No. 22-5128-02
69-1216
DEFINITIONS
Adaptive Intelligent Recovery™ Control
Adaptive Intelligent Recovery™ Control is the factory default setting that allows you to choose the exact time the
room reaches your comfort temperature, as opposed to conventional recovery.
Adaptive Intelligent Recovery™ Modes
WAKE You choose the exact time the room reaches your comfort temperature after the SLEEP period.
LEAVE You choose the time you want your heating or cooling system to start an energy-savings mode while
you are away (lower temperature during heating season, and higher temperature during cooling
season) – follows WAKE period.
RETURN You choose the exact time the room reaches your comfort temperature after the energy-savings
LEAVE period.
SLEEP You choose the time you want your heating or cooling system to start an energy-savings mode while
you sleep-follows RETURN period.
Conventional Recovery
Conventional recovery is an optional setting allows you to choose the exact time your heating or cooling system
comes on to start recovery, as opposed to Adaptive Intelligent Recovery™ Control.
64
Pub. No. 22-5128-02
69-1216
If your thermostat is set to conventional recovery, a indica-
tion displays continuously, as shown on the example display.
M12949
Auto
System Fan
Mon In
Room
AM
Recovery
Sleep
Heat
Conventional Recovery Modes
WAKE You choose the time you want your heating or cooling system to start to reach your comfort tempera-
ture after the SLEEP period. Adjust this time to earlier when you know it will take longer for the
system to reach your comfort temperature. Adjust this time to later when you know the SLEEP
temperature is closer to your WAKE temperature.
LEAVE You choose the time you want your heating or cooling system to start an energy-saving mode while
you are away (lower temperature during heating season, and higher temperature during cooling
season) – follows WAKE period.
RETURN You choose the time you want your heating or cooling system to start to reach your comfort tempera-
ture after the energy-savings LEAVE period.
SLEEP You choose the time you want your heating or cooling system to start an energy-savings mode while
you sleep-follows RETURN period.
65
Pub. No. 22-5128-02
69-1216
Preprogrammed Schedule
The preprogrammed schedule consists of the four periods (Wake, Leave, Return and Sleep) and accompanying
temperatures programmed into your thermostat at the factory. See Tables 1 and 4.
Period
One of the four times of the day (Wake, Leave, Return or Sleep) that you can program a setpoint or setpoints.
Setpoint
Setpoint is the temperature setting you select for a schedule or for a Hold. The setpoint can be either the heating
temperature you set or the cooling temperature. Setpoint does not refer to actual room temperature or outdoor
temperature.
System
System refers to either the heating and cooling mechanics. For example, when the System is set to Heat, the
heating mechanics operate according to the heating setpoint. The thermostat selects the System when set to
Auto. Some installations allow you to turn the System off (neither heating nor cooling will operate).
66
Pub. No. 22-5128-02
69-1216
INDEX
24-Hour Operation, 50
24-Hour Preprogrammed Schedule, 50
7-Day Operation, 33
7-Day Preprogrammed Schedule, 33
Adaptive Intelligent Recovery Control, 12
Auxiliary Heat, 9
Changing Temperature Setting Indefinitely, 17
Changing Temperature Setting Until the Next
Schedule Period, 15
Clearing Schedule Period, 47
Clock, 29
Comfort-R Comfort Enhancement System, 11
Constant Temperature Setpoint Programming, 57
Conventional recovery, 63
Copying a Day, 44
Daylight Time, 31
DEFINITIONS, 63
Displaying Current Settings, 25
Emergency Heat, 9
Energy Savings, 13
Filter Indication, 26
Information key, 24
keyboard, 6
LEAVE, 62, 63, 64
LED, 9
options, 5
Outdoor Temperature, 24
Period, 65
Programming the First Day, 39
RETURN, 63, 64
Saturday, 47
Set Fan, 32
Set System, 32
Setpoint, 65
Setting Current Day and Time, 29
SLEEP, 63, 64
The Trane Company, 67
Thermostat Customer Assistance Helpline, 68
Troubleshooting, 60
Vacation, 20
WAKE, 63, 64
warranty, 67
67
Pub. No. 22-5128-02
69-1216
LIMITED WARRANTY
Low Voltage Room Thermostats
This warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the
Thermostat is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada.
If any part of your Thermostat fails because of a manufacturing defect within one year from the date of the original purchase, Warrantor will
furnish without charge a new thermostat. Any local transportation, related service labor and diagnosis calls are not included.
This warranty does not cover failure of your Thermostat if it is damaged while in your possession or if the failure is caused by unreasonable use.
In no event shall Warrantor be liable for incidental or consequential damages. In no event shall any implied warranty of merchandise or
fitness for use exceed the term of the limited warranty stated above.
Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusion or limitation of incidental or consequen-
tial damages, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights
which vary from state to state.
Parts will be provided by our factory organization or an authorized service organization in your area. All you need to do is look us up in the Yellow
Pages or write to the address given below. If you wish further help or information concerning this warranty, contact:
American Standard Inc.
Troup Highway
Tyler, TX 75711-9010
Attention: Manager, After Sales Support
68
Pub. No. 22-5128-02
69-1216
Pub. No. 22-5128-02
T8611
69-1216 1-99 T.C.
American Standard Inc.
Troup Highway
Tyler, TX 75711-9010
CUSTOMER ASSISTANCE
If, after reading this guide, you have any questions concerning the operation of your thermostat, please call the
Thermostat Customer Assistance Helpline at 1-877-880-3381, Monday-Friday, 7:00 am-5:30 pm, Central time.
For service, contact your local heating and cooling contractor.