TransCore 10-510-100 Location and Monitoring Transmitter User Manual

TransCore Location and Monitoring Transmitter SUG

a href="https://usermanual.wiki/TransCore" itemprop="url"> TransCore >

Contents

Exhibit 8 Users Manual Supplement

FIntellitag® 500 SmartPass® Reader SystemModifications
Intellitag® 500 SmartPass® Reader System ModificationsF-3FThis appendix describes the changes made to the AI1620 SmartPass® Reader to make the system guide usable for the Intellitag® 500 SmartPass Reader system.IntroductionThis addendum to the AI1620 SmartPass® System Guide provides information about hardware and software modifications for the Intellitag 500 SmartPass Reader system.AudienceThis document is intended to be used by authorized SmartPass dealers, installers, and service personnel. Because SmartPass has no operator- or end-user-serviceable components or features, no end-user manual or operator guide exists. Once the system is set up and tested by the authorized installer, SmartPass operations requires no end-user intervention.Reader ModificationsThe following sections describe the proposed modification and reason for each of the Intellitag 500 SmartPass Reader system changes. Each section lists the modification, the background of the reason for the change (if provided), and the firmware commands affected by the change (if applicable).Reading of Mixed Population TagsModificationThe Intellitag 500 SmartPass Reader reads the American Trucking Association (ATA) or International Organization for Standardization (ISO) read-only type tags, whether battery or beam powered, or Intellitag 500 asynchronous integrated circuit (ASIC)-based tags.  The reader can read the ATA or ISO read-only tags in the presence of Intellitag 500-based tags; however, attempting to read a Intellitag 500-based tag in the presence of an ATA or ISO read-only tag might provide indeterminate results. At present, Amtech is aware that the performance under these conditions is strongly determined by physical and geometrical factors.BackgroundThe traditional Amtech read-only tags are continuously modulating regardless of the state of the reader or Intellitag 500 tags. Therefore, when a polling request signal is sent from the reader to the Intellitag 500 tags, it is probable that the read-only tags can interfere with the backscatter response from the Intellitag 500 tag. This creates
Download:
Mirror Download [FCC.gov]
Document ID75385
Application ID4jYwfTr5JYBnfiLVNRK0VQ==
Document DescriptionExhibit 8 Users Manual Supplement
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize1.7kB (21272 bits)
Date Submitted1999-12-10 00:00:00
Date Available2000-02-18 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.02 for Windows
Document Lastmod0000-00-00 00:00:00
Document TitleIT500_SP_App_F.PDF
Document CreatorIT500_SP_App_F.fm
Document Author: Unknown
FCC ID Filing: FIH10-510-100

Navigation menu