Transtek Medical Electronics GBF-1144-B Body Fat Analyzer User Manual GBF 1257 B 20130102
Guangdong Transtek Medical Electronics Co.,Ltd Body Fat Analyzer GBF 1257 B 20130102
Users Manual
version:1.0 User Manual Body Fat Analyzer FCC ID: OU9GBF1144-B ZHONGSHAN LIFESENSE ELECTRONICS CO., LTD 23,Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China TEL:86-760-88282982 www.transtek.cn GBF-1144-B Thank you very much for selecting the Transtek Body Fat Analyzer GBF-1144-B. Please do read the user manual carefully and thoroughly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems. Table of Contents Table of Contents Safety Information Safety and Usage Information ................................................................................................... 2 Your Scale and Its Environment ............................................................................................... 3 Efficient Use of Your Scale ...................................................................................................... 3 Overview Device Components ................................................................................................................. 4 LCD Display .............................................................................................................................. 5 Initial Start-Up General Instructions ................................................................................................................. 6 Insert the Batteries ................................................................................................................... 6 Install App and Pair-up ................................................ ............................................................ 7 Start Measuring Select Measurement Unit .......................................................................................................... 8 Daily Measurement .................................................................................................................. 9 Data Transmission Data Transmission .................................................................................................................... 10 Troubleshooting Error Prompt ............................................................................................................................. 11 When Measuring ... .................................................................................................................. 11-12 When Data Transmitting... ........................................................................................................ 13 Specifications ............................................................................................................................ 14 Maintenance ............................................................................................................................... 15 Warranty ...................................................................................................................................... 15 Appendix Table of Body Fat Level .......................................................................................................... 16 Health Tips – About Body Fat........................................ ............................................................ 16 EMC Guidance ......................................................................................................................... 17-21 Safety Information Safety Information Safety and Usage Information The warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows: Symbol for “THE OPERATION GUIDE MUST BE READ” Symbol for “MANUFACTURER” The Bluetooth Combination Mark Symbol for “DIRECT CURRENT” Symbol for “TYPE BF APPLIED PARTS” Symbol for “SERIAL NUMBER” Symbol for “MANUFACTURE DATE” Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice” CAUTION The Transtek Body Fat Analyzer measures weight , and uses bio-electrical impedance analysis (BIA) technology to estimate body fat, total body water percentage, bone mass, and muscle mass in generally healthy children 10-17 years old and healthy adults. It is intended for use in the domestic setting only. CONTRAINDICATIONS 1. This device is contraindicated for any female subject who may be suspected of, or is pregnant. Besides provided inaccurate readings, the affects of this device on the fetus are unknown. 2. This device is contraindicated for any person who is connected to a wearable or implantable electronic device or instrument such as a pacemaker or defibrillator. Your Scale and Its Environment To ensure your safety as well as the service life of your scale, please avoid using the scale under the following circumstances: Slippery floor such as tile floor Jumping onto the platform immediately after bath or with wet feet The Body Fat Analyzer GBF-1144-B offers you a seamless way to manage your health. Please be aware that this device is designed for adults’ self-measuring and self-monitoring body fat level. Any information provided by this device is in no way meant to treat, cure or prevent any disease or illness from happening. This device should not be used by anyone who is acutely or chronically ill, suffering from a disease or taking medications that affect your water levels. The accuracy of readings for these patients has not been verified. Specific medical advice should be obtained from a physician. Before diet and exercise, you must first find a professional medical guide. Near a cell phone or microwave oven The body fat analyzer is equipped with data transmission function. It may emit electromagnetic energy so as to perform its intended function. Nearby portable and mobile RF communications equipment can affect the performance of the device . Where there is risk of shock or drop Portable and mobile RF communications equipment can affect the measuring accuracy of the body fat analyzer. Kindly note that the use of accessories, transducers or cables other than those specified, with the exception of transducers and cables sold by the manufacturer as replacement parts for internal components, may result in increased EMISSIONS or decreased IMMUNITY of the device. INDICATIONS FOR USE Be aware that misuse of electrical equipments can cause electric shock, burns, fire and other hazards. Please do not use the device in flammable gas environment. Warning that the body fat analyzer should not be used adjacent to or stacked with other equipment. Manufacturer will make available on request circuit diagrams, component parts list,etc. WARNING:No modifications of this equipment is allowed. During using the analyzer, the patient will contact with the surface and the electrode of the Analyzer. The surface and the electrode of the analyzer is type BF Applied part. The device doesn’t need to be calibrated in five years lifetime. Do not touch the output of batteries when using the analyzer. The patient is an intended operator. The patient can perform all the operations in the manual, such as measurement, data transmitting, changing batteries. Avoid storage in the following locations: Where there is water Where the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt air Where you store chemicals or full of corrosive gases Where in reach of the infants or children Efficient Use of Your Scale To ensure the accuracy of measurement, please follow below instructions when you start measurement. Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the scale. Step onto the platform with bare feet. Stand still and keep full contact with the scale until the measurement is complete. Start measurement at least two hours after Getting up or Dinning. Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dinning. Always start measurement in the same time slot and on the same scale located on the same flat, hard surface. Overview Overview LCD Display Device Components LCD Display UNIT Button Battery Compartment List Pending to transmit to wireless wellness system Stone Data Transmitting Pound Bioelectrical Impedance Analysis Kilogram 1. Body Fat Analyzer GBF-1144-B 2. Three AAA-size Batteries (1.5V per each) 3. User Manual Low Battery Initial Start-Up General Instructions Transtek Body Fat Analyzer GBF-1144-B applies BIA (Bio-impedance Analysis) technology. A small amount of weak current flows through the human body so as to detect the bio-impedance and estimate body fat. The electrical current is small and may not be felt. This BIA technology is cheap, safe, non-invasive, toxic-free and harmless. It also possesses the characteristics of simple operation and abundant information. The current mentioned above is less than 0.5mA. However, please be aware that anyone with an wearable or implantable medical electronic instrument, such as a pacemaker, must avoid using this device. The intended use of this device is for healthy children 10-17 years old and healthy adults. Insert the Batteries Open the battery door in the back of the scale. Initial Start-Up Install the App and Pair-Up With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, which are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG, are capable to receive your personal health data. Just simply install the specially-designed app and pair up your scale with your mobile or portable equipments. Then you may enjoy the comprehensive health solution provided by Transtek. Note: It is only available for the device which supports Bluetooth 4.0 technology. Turn on Bluetooth and the App. Make sure both are ON when pair-up is proceeding. Press and hold “UNIT” button in the back of the scale to start pair-up. Symbol and symbol is proceeding. will be shown on the LCD alternatively, indicating pair-up Insert the batteries (3 x 1.5V AAA) into the battery compartment according to the polarity indications marked inside the compartment. * The digits “8888” will be shown on the LCD. Close the battery door and wait until the digits “0.0kg” are shown on the LCD. If SUCCEED, symbol will be shown on the LCD. CAUTION When the symbol appears, the device will power off in three seconds. Then you shall replace with a new set of batteries. Please replace all three batteries at the same time. Do NOT mix the old batteries with the new one. Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries and scrapped device. Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact you local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. If you do not intend to use this unit for a prolonged period of time, it is advisable to remove the batteries before storing. If FAIL, symbol “E1” will be shown on the LCD. Initial Start-Up Select Measurement Unit With batteries correctly installed, press “UNIT” button in the back of the scale to select measurement unit. The default measurement unit is “kilogram”. You may press “UNIT” button to choose among kilogram, stone and pound. Start Measuring Daily Measurement With original SENSE ON patent technology, GBF-1144-B will automatically switch on as you step on the platform barefooted. Stand still and keep full contact with the electrodes until the LCD displays the weight and stops blinking the unit. When the weight is locked, the symbol “BIA” blinks, indicating the Bioelectrical Impedance Analysis is proceeding. If the Bioelectrical Impedance Analysis measurement is sucessful, the symbol “BIA” will remain. If it fails, the symbol “BIA” will disappear. After the symbol “BIA”stops blinking, the symbols “ ” and “ ” light up.When your scale is successfully paired with your smartphone and the Bluetooth is ON, it will process data transmission automatically. (Please refer to Data Transmission for more details.) Data Transmission Troubleshooting Error Prompt Data Transmission Error With GBF-1144-B successfully pair-up with your smartphone, the measurement data will be transmitted to your mobile via Bluetooth. The symbol will disappear after successful data transmission, and you may check your personal health data stored in your smartphone. If the data transmission fails, the symbol will remain. The pending measurement data will be temporarily kept in the scale and transmitted to your smartphone when next measurement is complete. Data transmitting Data transmitting to wireless wellness system: -If SUCCEED, the symbol disappears; -If FAIL, the symbol remains. Description Solution Overload. The device will power off. Stop using this scale for measurement. Low Battery. The device will power off in three seconds. Replace all three batteries at the same time. Please purchase the authorized batteries for replacement. Failure of pairing up . There has data doesn’t upload. (The notebook icon will be displayed.) Please check below items: -Bluetooth is ON. -App Collector is ON. -Both devices are within the transmission distance of Bluetooth. Upload the data. CAUTION Interference may occur in the vicinity of equipment marked with the following symbol the Analyzer may interfere vicinity electrical equipment. . And To enable the data transmission function, this product should be paired to a Bluetooth 4.0 end. How to mitigate possible interference? 1. The range between the Analyzer and the Bluetooth end should be reasonably close, from 1 meter to 10 meters. Please ensure no obstacles between the Analyzer and the Bluetooth end so as to obtain quality connection. 2. To avoid interference, other electronic devices (particularly those with Bluetooth transmission / Transmitter) should be kept at least 1 meter away from the Analyzer. 10 When Measuring ... Problem Abnormal measuring results: - Too high; OR - Too low; OR - Huge difference between two recent measurement. Root Cause Incorrect posture The device is located on the soft ground such as a carpet OR on a rugged surface. Solution Please step on the platform barefooted and stand still. Please place the device on a flat, hard surface. 11 Troubleshooting Troubleshooting When Data Transmitting ... Problem Root Cause Solution Problem Abnormal measuring results: - Too high; OR - Too low; OR - Huge difference between two recent measurement. Your feet are too dry. Batteries not yet installed. Install the batteries. (Please refer to Insert the Batteries) Worn batteries. Replace all three batteries at the same time. Please purchase the authorized batteries for replacement. No display on LCD when the device powers on. CANNOT proceed to analyze body fat The device powers off. 12 Wipe your feet with a damp cloth, keeping them slightly damp when starting measurement. Step onto the platform wearing socks or shoes. Low battery. Data transmission failed. Root Cause Solution Bluetooth is OFF. Turn ON the Bluetooth via the Settings. App is OFF. Press the icon to run your App. Out of range of Bluetooth transmission. Place your smartphone closer to the scale. Please keep barefooted during the measurement, and keep full contact with the electrodes as well. Replace all three batteries at the same time. Please purchase the authorized batteries for replacement. 13 Specifications Maintenance Specifications Product Name When carrying out usual maintenance, please ensure practice of the following Do’s and Don’ts: Dimension Scale: 310x306x27.6mm (Approximately) Net Weight Approximately 1.572kg ( Excluding the dry cells) DO use a dry soft cloth to wipe the dust. Digital LCD DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a dry soft cloth to dry up the device. Display Measurement Unit Measurement Range Division Accuracy Working Environment Storage and Transport Environment Power Source Turn on Method Auto-OFF Accessories 14 Maintenance Body Fat Analyzer DON’T wash the device with water or immerse it in water. Kilogram / Stone/ Pound 5kg to 150kg /0st: 11lb to 23st: 8lb/ 11lb to 330.6lb 0.1kg / 0.2lb/1lb (≥20st) 50kg: ±0.3kg; 150kg: ±0.5kg; Relative Humidity: ≤90% RH Atmospheric pressure: 86kPa to 106kPa Temperature: -20℃ to 60℃ Relative Humidity: ≤90% RH Atmospheric pressure: 50kPa to 106kPa 4.5V (Three AAA-size Batteries) SENSE ON technology About 60s for the first time after being installed batteries and showing 0.0; About 10s for other times when it showing 0.0; About 15 seconds when the weight data is unstable. 1. Three AAA-size Batteries 2. User Manual Continuous Operation Degree of protection Type BF applied part Software Version A04 Protection Against Ingress of Water IP21 DON’T disassemble this device. If you have any problems, please contact Transtek. (Please refer to Warranty for contact information) 100kg: ±0.4kg; Temperature: 5℃ to 40℃ Mode of Operation DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunction. About the Accuracy of This Product This product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer. Please refer to the above table for the descriptions on accuracy. This product is specially designed for body fat analysis as well as weight measurement. It should NOT be used by anyone during the process of transaction for verification of goods’ weight. Warranty Transtek warrants its products free of defects in materials and workmanship in normal use for a period of FIVE years from the date of retail purchase. This warranty does NOT cover damages caused by misuse or abuse, including but not limited to: Failure caused by unauthorized repairs or modifications; Damage caused by shock or drop during transportation; Failure caused by improper operation inconsistent with the instructions stated in this user manual; Malfunction or damage from failure to provide the recommended maintenance; Damage caused by improper use of power supply. Should this device require maintenance (or replacement at our option) under warranty, please deliver the original package to ZHONGSHAN LIFESENSE ELECTRONICS CO., LTD prepaid. Please return the store receipt (with the retail purchase date) and a note with reasons to return on it as well. ZHONGSHAN LIFESENSE ELECTRONICS CO., LTD 23,Jin'an Road, Minzhong, Zhongshan, 528441, Guangdong, China Tel: 86-760-88282982 Website: http://www.transtek.cn 15 Appendix Appendix FCC Regulations FCC User Guide Information Radio Frequency Interface Requirements - FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna; Increase the separation between the equipment and receiver; Connect the equipment into an outlet on a circuit different from that to which the receiver is connected; Consult the dealer or an experienced radio / TV technician for help. Radio Transmitters (Part 15) This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. FCC RF Exposure Guidelines Table of Body Fat Level (Unit: %) a) The body fat percentage (%): 5%-60%/0.1% Standard for Men Standard for Women Rating low Normal Age 20-29 30-39 <13 <14 <16 13-20 14-21 16-23 40-49 Rating 50-59 60+ <17 <18 17-24 18-25 low Normal Age 20-29 30-39 40-49 50-59 <19 <20 <21 <22 <23 19-28 20-29 21-30 22-31 23-32 60+ Moderately High 20.1-23 21.1-24 23.1-26 24.1-27 25.1-28 Moderately High 28.1-31 29.1-32 30.1-33 31.1-34 32.1-35 High >23 >24 >26 >27 >28 High >31 >32 >33 >34 >35 Source: University of Illinois Department of Food Science and Human Nutrition. Body Fat Percentage Calculator. Health Tips - About Body Fat Fat is essential for human body. It can not only store energy and protect viscera, but also regulate body temperature and maintain normal physiological function of human body. However, too much body fat is harmful to human body. It is always accompanied by Fatty Liver, diabetes, coronary heart disease, etc. Therefore self-measuring and self-monitoring body fat level are beneficial to your health. Since we can’t judge body fat level simply by our weight, this body fat analyzer , with BIA (Bio-impedance Analysis) technology applied, is an accurate device that offers a quick and comfortable way to obtain your body fat level. Safety Information Reducing RF Exposure - Use Properly Only operate the device in accordance with the instructions supplied. This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. 16 17 Appendix Appendix EMC Guidance Table 2 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY – for all ME EQUIPMENT and ME SYSTEMS Table 1 Guidance and MANUFACTURER’s declaration – ELECTROMAGNETIC EMISSIONS- for all ME EQUIPMENT and ME SYSTEMS Guidance and manufacturer’s declaration – electromagnetic emissions The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. Emissions test RF emissions CISPR 11 RF emissions CISPR 11 Harmonic emissions IEC 61000-3-2 Compliance Group 2 Class B flicker emissions IEC The device must emit electromagnetic energy in order to perform its intended function. Nearby electronic equipment may be affected. The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment IMMUNITY test Electrostatic discharge (ESD) IEC 61000-4-2 Not applicable IEC 60601 test level ±6 kV contact ±8 kV air Electrical fast transient/burst IEC 61000-4-4 ±2 kV for power supply lines ±1 kV for input/output lines Surge IEC 61000-4-5 ±1 kV line(s) to line(s) ±2 kV line(s) to earth Not applicable Voltage fluctuations/ 61000-3-3 Electromagnetic environment - guidance Guidance and manufacturer’s declaration – electromagnetic immunity Voltage dips, short interruptions and voltage variations on power supply input lines IEC 61000-4-11 <5% UT (>95% dip in UT for 0.5 cycle 70% UT (30% dip in UT for 25 cycles ±6 kV contact ±8 kV air Not applicable Mains power quality should be that of a typical commercial or hospital environment. Not applicable Mains power quality should be that of a typical commercial or hospital environment. Not applicable IEC 61000-4-8 NOTE 18 3A/m Mains power quality should be that of a typical commercial or hospital environment. If the user of the device requires continued operation during power mains interruptions, it is recommended that the device be powered from an uninterruptible power supply or a battery. Power frequency (50/60Hz) magnetic field Electromagnetic environment - guidance Floors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%. 40% UT (60% dip in UT for 5 cycles <5% U T (>95% dip in UT for 5 s Compliance level 3A/m Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment. UT is the a.c. mains voltage prior to application of the test level. 19 Appendix Appendix Table 4 Guidance and MANUFACTURER’s declaration – electromagnetic IMMUNITY – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING Guidance and manufacturer’s declaration – electromagnetic immunity The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment. IMMUNITY test IEC 60601 TEST LEVEL Compliance level Electromagnetic environment guidance Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter. Conducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2.5 GHz Not applicable 3 V/m Recommended separation distance 3,5 d=[ ] P V1 d = 1.167 P 80 MHz to 800 MHz Recommended separation distances between portable and mobile RF communications equipment and the device. The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmittters) and the device as recommended below, according to the maximum output power of the communications equipment. Rated maximum output power of transmitter (W) Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, a should be less than the compliance level in each frequency range. b Interference may occur in the vicinity of equipment marked with the following symbol: Separation distance according to frequency of transmitter (m) 150 kHz to 80 MHz 3,5 d=[ ] P V1 d = 2.333 P 800 MHz to 2,5 GHz where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). NOTE 1 NOTE 2 Table 6 Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM – for ME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTING 80 MHz to 800 MHz 800 MHz to 2.5 GHz d = 1.167 P d = 2.333 P 0.01 Not applicable 0.117 0.233 0.1 Not applicable 0.369 0.738 Not applicable 1.167 2.333 10 Not applicable 3.690 7.378 100 Not applicable 11.67 23.33 For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80MHz and 800MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. a Field strengths from fixed transmitters, such as base stations for radio (cellular / cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the device. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [V 1]V/m. 20 21
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No XMP Toolkit : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00 Format : application/pdf Title : GBF-1257-B 说明书20130102 Description : User Manual Creator : Shuting Creator Tool : Adobe Illustrator CS5 Create Date : 2013:01:02 09:32:43+08:00 Modify Date : 2017:06:23 17:29:14+08:00 Metadata Date : 2017:06:23 17:29:14+08:00 Thumbnail Width : 44 Thumbnail Height : 256 Thumbnail Format : JPEG Thumbnail Image : (Binary data 3352 bytes, use -b option to extract) Original Document ID : uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7 Document ID : xmp.did:465A56547754E2118865C2E3DC882209 Instance ID : uuid:9e9f7e82-6b33-43de-b319-5be407cc1d5f Rendition Class : proof:pdf History Action : converted, saved, converted, converted, saved, converted, saved, converted, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved History Params : from application/pdf toEXIF Metadata provided by EXIF.toolsHistory Instance ID : xmp.iid:D07F11740720681191099C3B601C4548, xmp.iid:FC7F117407206811B628E3BF27C8C41B, xmp.iid:FD7F117407206811B628E3BF27C8C41B, xmp.iid:0CC3BD25102DDD1181B594070CEB88D9, xmp.iid:03E540664A3DDD11BD33D3EB8D3A1068, xmp.iid:6D6AE2A5723EDD11A6F1BABF7C5A7A51, xmp.iid:20383BFEA441DD11A6AECB58D53C8B28, xmp.iid:096F577ABE41DD11A6AECB58D53C8B28, xmp.iid:AB13E990200911689FE8CB9EA85C5459, xmp.iid:95D9A2DF7848DD11BB47877F8DDF9079, xmp.iid:F87F117407206811B34B80FC905F8DB1, xmp.iid:FE7F11740720681197A5C6DA8C2593EE, xmp.iid:FF7F11740720681197A5C6DA8C2593EE, xmp.iid:D5E97F3291E4DE11831BCC4BA24AAFD8, xmp.iid:3E09327B1FEADE119648D46DE661B201, xmp.iid:A8F46C6799EBDE118B29BF0F76361FFD, xmp.iid:233794C82A12DF11A1FB8DE093AEEF16, xmp.iid:E9171D43F3ABDF119F67BD126A85E7C0, xmp.iid:ED171D43F3ABDF119F67BD126A85E7C0, xmp.iid:A98329CBEEDCDF119F6AFE1DA0EB4A56, xmp.iid:F0D7C34F6BE9DF11BB38870380B6B2A6, xmp.iid:3097A67DCCEADF11AC9EC8ACF64A7DDE, xmp.iid:9550DF26AFEBDF119A34BB36D9091C95, xmp.iid:91B2A8E3B31EE0118388C60B75F0B421, xmp.iid:C66F62307E1FE011B297ADA3E90C4992, xmp.iid:32111635E540E211A2A3C2ACD38E298D, xmp.iid:D8BE93E0064BE211992AB2AA5473309D, xmp.iid:925B3A1E5351E211BB2AA5B5C8B3A954, xmp.iid:945B3A1E5351E211BB2AA5B5C8B3A954, xmp.iid:465A56547754E2118865C2E3DC882209 History When : 2008:04:17 14:19:10+05:30, 2008:05:22 14:51:08-07:00, 2008:05:22 15:15:38-07:00, 2008:05:28 17:07:17-07:00, 2008:06:18 22:24:35+07:00, 2008:06:19 20:31:09-07:00, 2008:06:24 13:29:32+08:00, 2008:06:24 15:24:18+08:00, 2008:06:26 06:04:07-07:00, 2008:07:02 13:54:46-07:00, 2008:07:21 16:58:27+05:30, 2008:09:05 04:29:47-07:00, 2008:09:05 04:30:01-07:00, 2009:12:09 17:43:05+08:00, 2009:12:16 16:46:19+08:00, 2009:12:18 17:47:07+08:00, 2010:02:05 15:48+08:00, 2010:08:20 08:39:57+08:00, 2010:08:20 12:32:03+08:00, 2010:10:21 16:40:01+08:00, 2010:11:06 14:40+08:00, 2010:11:08 09:13:48+08:00, 2010:11:09 11:24:26+08:00, 2011:01:13 11:20:28+08:00, 2011:01:14 09:32:45+08:00, 2012:12:08 13:29:51+08:00, 2012:12:21 08:57:37+08:00, 2012:12:29 16:12:58+08:00, 2012:12:29 17:15:49+08:00, 2013:01:02 09:32:35+08:00 History Software Agent : Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5 History Changed : /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, / Derived From Instance ID : uuid:fd0e9828-d634-481c-bfd0-83f216b2d2e9 Derived From Document ID : xmp.did:945B3A1E5351E211BB2AA5B5C8B3A954 Derived From Original Document ID: uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7 Derived From Rendition Class : proof:pdf Startup Profile : Basic RGB N Pages : 1 Has Visible Transparency : True Has Visible Overprint : True Max Page Size W : 256.999817 Max Page Size H : 182.000605 Max Page Size Unit : Millimeters Font Name : Arial-Black, Arial-BlackItalic, Arial-BoldItalicMT, ArialMT, Arial-BoldMT, AdobeSongStd-Light, SimHei, TimesNewRomanPS-ItalicMT Font Family : Arial, Arial Black, Arial, Arial, Arial, Adobe 宋体 Std, 黑体, Times New Roman Font Face : Black, Italic, Bold Italic, Regular, Bold, L, Regular, Italic Font Type : Open Type, TrueType, Open Type, Open Type, Open Type, Open Type, Open Type, Open Type Font Version : Version 5.06, Version 1.00, Version 5.06, Version 5.06, Version 5.06, Version 5.002;PS 5.002;hotconv 1.0.49;makeotf.lib2.0.15106, Version 5.01, Version 5.07 Font Composite : False, False, False, False, False, False, False, False Font File Name : ariblk.ttf, Arial Black Italic_0.TTF, ARIALBI.TTF, arial.ttf, arialbd.ttf, AdobeSongStd-Light.otf, simhei.ttf, TIMESI.TTF Plate Names : Cyan, Magenta, Yellow, Black, PANTONE 877 C, PANTONE 286 CVU Swatch Group Name : 默认色板组, 灰度, 初始屏幕 Swatch Group Type : 0, 1, 1 Swatch Colorant Swatch Name : 白色, 黑色, RGB 红, RGB 黄, RGB 绿, RGB 青, RGB 蓝, RGB 洋红, R=193 G=39 B=45, R=237 G=28 B=36, R=241 G=90 B=36, R=247 G=147 B=30, R=251 G=176 B=59, R=252 G=238 B=33, R=217 G=224 B=33, R=140 G=198 B=63, R=57 G=181 B=74, R=0 G=146 B=69, R=0 G=104 B=55, R=34 G=181 B=115, R=0 G=169 B=157, R=41 G=171 B=226, R=0 G=113 B=188, R=46 G=49 B=146, R=27 G=20 B=100, R=102 G=45 B=145, R=147 G=39 B=143, R=158 G=0 B=93, R=212 G=20 B=90, R=237 G=30 B=121, R=199 G=178 B=153, R=153 G=134 B=117, R=115 G=99 B=87, R=83 G=71 B=65, R=198 G=156 B=109, R=166 G=124 B=82, R=140 G=98 B=57, R=117 G=76 B=36, R=96 G=56 B=19, R=66 G=33 B=11, 新建色板 51, 新建色板 445, 新建色板 308, 新建色板 243, 新建色板 28, 新建色板 250, 新建色板 611, 新建色板 54, 新建色板 632, 新建色板 246, 新建色板 59, 新建色板 291, 新建色板 249, 新建色板 677, 新建色板 852, 新建色板 33, 新建色板 884, 新建色板 883, 新建色板 882, 新建色板 120, 新建色板 177, 新建色板 152, 新建色板 75, 新建色板 222, 新建色板 1148, 新建色板 233, 新建色板 1139, 新建色板 227, 新建色板 200, 新建色板 218, 新建色板 221, 新建色板 216, 新建色板 162, 新建色板 170, 新建色板 193, 新建色板 219, 新建色板 194, 新建色板 171, Global Black, PANTONE 286 CVU, AutoCAD Color 3, AutoCAD Color 1, AutoCAD Color, AutoCAD Color 2, AutoCAD Color 4, AutoCAD Color 5, New Color Swatch, PANTONE 877 C, R=0 G=0 B=0, R=26 G=26 B=26, R=51 G=51 B=51, R=77 G=77 B=77, R=102 G=102 B=102, R=128 G=128 B=128, R=153 G=153 B=153, R=179 G=179 B=179, R=204 G=204 B=204, R=230 G=230 B=230, R=242 G=242 B=242, R=214 G=149 B=68, R=71 G=152 B=237, R=42 G=81 B=224, R=180 G=58 B=228 Swatch Colorant Mode : CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK, CMYK Swatch Colorant Type : PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, SPOT, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS, PROCESS Swatch Colorant Cyan : 0.000000, 0.000000, 0.000000, 6.250000, 62.500000, 51.562500, 87.890601, 26.953101, 16.796899, 0.390601, 0.000000, 0.000000, 0.000000, 4.687500, 18.750000, 50.000000, 74.218798, 85.937500, 89.843798, 75.781298, 78.125000, 69.531298, 87.109399, 98.828101, 100.000000, 74.218798, 49.218798, 34.765601, 11.718798, 0.000000, 22.656298, 39.843798, 50.390601, 57.421899, 22.656298, 31.640601, 35.937500, 39.062500, 41.406298, 47.656298, 14.000000, 20.000000, 0.000000, 20.000000, 0.000000, 0.000000, 10.000000, 0.000000, 0.000000, 100.000000, 20.000000, 40.000001, 0.000000, 61.000001, 31.999999, 41.000000, 0.000000, 63.000000, 2.000000, 28.999999, 74.000001, 100.000000, 7.000000, 3.000000, 0.000000, 69.999999, 0.000000, 3.000000, 5.000000, 26.999998, 0.000000, 1.000000, 2.000000, 26.999998, 87.000000, 5.000000, 64.999998, 0.000000, 75.020999, 100.000000, 92.971700, 54.924798, 92.971700, 92.971700, 27.286199, 37.241200, 92.971700, 0.000000, 74.609399, 72.265601, 69.140601, 65.234399, 59.375000, 51.562500, 42.578101, 30.468798, 19.140601, 8.593798, 3.515601, 15.234399, 65.234399, 82.421899, 48.046899 Swatch Colorant Magenta : 0.000000, 0.000000, 98.828101, 0.000000, 0.000000, 0.000000, 76.562500, 81.250000, 97.656298, 98.828101, 79.296899, 50.000000, 34.765601, 0.000000, 0.000000, 0.000000, 0.000000, 17.578101, 33.203101, 0.000000, 8.984399, 14.843798, 52.343798, 96.093798, 100.000000, 98.046899, 98.828101, 100.000000, 100.000000, 96.484399, 27.343798, 42.578101, 52.734399, 60.156298, 38.281298, 48.828101, 57.031298, 63.671899, 69.531298, 73.046899, 0.000000, 0.000000, 20.000000, 0.000000, 0.000000, 0.000000, 0.000000, 10.000000, 0.000000, 0.000000, 100.000000, 0.000000, 100.000000, 19.000000, 51.999998, 0.000000, 61.000001, 83.999997, 77.999997, 0.000000, 57.999998, 100.000000, 40.000001, 7.000000, 0.000000, 10.000000, 0.000000, 30.000001, 7.000000, 25.000000, 16.000000, 5.000000, 50.999999, 0.000000, 74.000001, 42.999998, 30.000001, 82.999998, 67.968297, 60.000002, 87.972802, 0.003100, 87.972802, 87.972802, 44.016200, 76.470602, 87.972802, 0.000000, 67.578101, 66.406298, 62.890601, 57.812500, 51.171899, 42.968798, 34.765601, 24.218798, 14.843798, 6.250000, 2.343798, 44.140601, 32.812500, 70.703101, 78.906298 Swatch Colorant Yellow : 0.000000, 0.000000, 100.000000, 96.093798, 100.000000, 12.500000, 0.000000, 0.000000, 92.187500, 96.875000, 96.484399, 98.046899, 86.718798, 92.968798, 97.656298, 98.828101, 99.218798, 100.000000, 98.437500, 74.609399, 45.703101, 0.000000, 0.000000, 3.515601, 26.171899, 0.781298, 1.171899, 37.109399, 49.218798, 20.312500, 39.843798, 52.343798, 60.546899, 63.671899, 63.281298, 73.828101, 83.593798, 92.968798, 96.484399, 83.203101, 0.000000, 40.000001, 20.000000, 20.000000, 0.000000, 0.000000, 20.000000, 10.000000, 0.000000, 0.000000, 80.000001, 0.000000, 100.000000, 71.999997, 0.000000, 71.999997, 34.000000, 0.000000, 42.999998, 22.999999, 0.000000, 0.000000, 63.000000, 13.000000, 0.000000, 5.000000, 0.000000, 30.000001, 22.999999, 22.999999, 64.999998, 16.000000, 16.000000, 20.000000, 0.000000, 47.000000, 41.000000, 42.999998, 67.022198, 0.000000, 89.019603, 17.715700, 89.019603, 89.019603, 99.426299, 0.003100, 89.019603, 0.000000, 66.796899, 64.843798, 61.718798, 56.640601, 50.390601, 42.968798, 35.156298, 24.609399, 15.625000, 6.640601, 2.343798, 85.546899, 0.000000, 0.000000, 0.000000 Swatch Colorant Black : 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 6.640601, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 3.906298, 25.781298, 0.000000, 0.000000, 0.000000, 0.000000, 0.390601, 24.609399, 0.390601, 0.000000, 10.937500, 0.781298, 0.000000, 0.000000, 6.640601, 23.437500, 41.796899, 1.171899, 9.765601, 22.656298, 35.546899, 48.828101, 67.968798, 0.000000, 20.000000, 0.000000, 0.000000, 0.000000, 100.000000, 0.000000, 0.000000, 69.999999, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 100.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 0.000000, 20.999999, 0.000000, 90.164000, 6.000000, 79.998499, 0.003100, 79.998499, 79.998499, 0.003100, 0.003100, 79.998499, 40.000001, 89.843798, 77.734399, 58.203101, 36.328101, 19.921899, 7.421899, 1.171899, 0.000000, 0.000000, 0.000000, 0.000000, 0.781298, 0.000000, 0.000000, 0.000000 Swatch Colorant Tint : 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000, 100.000000 Producer : Adobe PDF library 9.90 Page Count : 12 Author : Shuting Keywords : GBF-1251-B Subject : User Manual