Transtek Medical Electronics GBS-1269B Bluetooth body scale User Manual LS406 B

Guangdong Transtek Medical Electronics Co.,Ltd Bluetooth body scale LS406 B

GBS-1269-B user manual

GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTDZone A, No.105, Dongli Road, Torch Development District, Zhongshan, Guangdong, 528437, ChinaTEL:86-760-88282982  www.transtek.cnversion:1.0User ManualBody  Scale GBS-1269-BPlease do read the user manual carefully and thoroughly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.Thank you very much for selecting the Transtek Body Scale GBS-1269-B.Contains FCC ID: OU9AW8001-LS
1Table of ContentsTable of ContentsOverviewDevice ComponentsLCD DisplayInitial Start-UpGeneral InstructionsInsert the BatteriesInstall App and Pair-upStart MeasuringDaily MeasurementData ManagementData TransmissionTroubleshootingError PromptWhen Measuring When Data TransmittingSpecificationsMaintenanceWarranty 45 46789101111121313.................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................2........................................................................................................................................................................ .............................................................................................................................................................................................................................................................................................................Select Measurement Unit 8Safety InformationYour Scale and Its Environment  3.............................................................................................Efficient Use of Your Scale  3............................................................................................................................................ ............................................................Symbol MeaningSymbol MeaningFCC Regulations ..........................................................................................................................   14
Symbol for “TYPE BF APPLIED PARTS” 2 3To ensure your safety as well as the service life of your scale, please avoid using the scale under the following circumstances:Slippery floor such as tile floorJumping onto the platform immediately after bath or with wet handsNear a cell phone or microwave ovenAvoid storage in the following locations:Where there is waterWhere the device may be exposed to extreme temperatures, humidity, moisture, direct sunlight, dust, or salt airWhere there is risk of shock or dropWhere you store chemicals or full of corrosive gasesWhere in reach of the infants or children Your Scale and Its EnvironmentEfficient Use of Your ScaleTo ensure the accuracy of measurement, please follow below instructions when you start measurement.Place the scale on a flat, hard surface. Soft surface such as carpet will affect the performance of the scale.Start measurement at least two hours after Getting up or Dinning.Avoid measurement immediately after strenuous exercise, sauna or bath, drinking, and dinning.Always start measurement in the same time slot and on the same scale located on the same flat, hard surface.Symbol Meaning Safety InformationThe warning signs and symbols are essential to ensure your correct and safe use of this product and protect you and others from injury. Please kindly find the meanings of the warning signs and symbols, which you may encounter in the label and user manual, as follows:Symbol MeaningSymbol for “THE OPERATION GUIDE MUST BE READ” Symbol for “MANUFACTURER”Symbol for “ENVIRONMENT PROTECTION – Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice”The Bluetooth Combination MarkSymbol for “SERIAL NUMBER”Symbol for “DIRECT CURRENT”
Transtek Body Scale GBS-1269BT applies SENSE ON technology. It’s notnecessary to turn on or turn off the scale, just stand on the scale for measurement.It is delicate and trendy, convenience for using.54List1. Body Scale GBS-1269-B2. Three AAA-size Batteries (1.5V each)3. User ManualDevice ComponentsBattery CompartmentUNIT and activation ButtonPoundKilogram Data transmittingData pending to transmit to wireless wellness systemLow BatteryLCD DisplayOverviewGeneral InstructionsLCD displayOverviewBioelectrical Impedance Analysis
    Note: It is only available for the device which supports Bluetooth 4.0 technology.76Insert the BatteriesOpen the battery door in the back of the scale.Insert the batteries (3 x 1.5V AAA) into the battery compartment according to the polarity indications marked inside the compartment.* The digits “8888” will be shown on the LCD.Close the battery door and wait until the digits “0.0kg” are shown on the LCD.CAUTIONWhen the symbol         appears, the device will power off in four seconds. Then you shall replace with a new set of batteries. Please replace all three batteries at the same time. Do NOT mix the old batteries with the new one. Worn batteries are hazardous waste. Do NOT dispose of them together with the household garbage. Please refer to the local ordinances and recycling instructions regarding disposal of the worn batteries.If SUCCEED, symbol         will be shown on the LCD.If FAIL, symbol “E1” will be shown on the LCD.Install App and Pair-UpYou may search and install the app in your smartphone. With the advanced Bluetooth 4.0 technology applied, the mobile or portable equipments, which are equipped with Bluetooth function in line with BLE Technical Specifications as well as BLP Protocol established by global organization Bluetooth SIG, are capable to receive your personal health data.Just simply install the specially-designed app and pair up your scale with your mobile or portable equipments. Then you may enjoy the comprehensive health solution provided by Transtek.Turn on Bluetooth and App. Make sure both are ON when pair-up is proceeding.Press and hold “UNIT” button in the back of the scale to start pair-up. Symbol         and symbol         will be shown on the LCD alternatively, indicating pair-up is proceeding.Initial Start-Up Initial Start-Up
With batteries correctly installed, press “UNIT” button in the back of the scale to select measurement unit. The default measurement unit is “kg”. You may press “UNIT” button to choose between kilogram and pound.89Select Measurement UnitWith original SENSE ON patent technology, the scale will automatically switch on as you step on the platform barefooted. When your scale is successfully paired with your smartphone and the Bluetooth is ON, it will process data transmission automatically. (Please refer to Data Transmission for more details.)Daily MeasurementWith the scale successfully pair-up with your smartphone, the measurement data will be automatically transmitted to your mobile via Bluetooth.The symbol      will disappear after successful data transmission, and you may check your personal health data stored in your smartphone.If the data transmission fails, the symbol      will remain. The pending measurement data will be temporarily kept in the scale and transmitted to your smartphone when next measurement is complete.Data ready to transmit toData transmitting the App:-If SUCCEED, the symbol disappears;-If FAIL, the symbol remains.Data TransmissionStand still and keep full contact with the scale until the LCD displays the weight and stops blinking the unit.Note: Whether the data transmission is successful , the device will shut down automatically  5 seconds later.Data ManagementStart Measuring
10 11Error PromptError Description SolutionOverload.   Stop using this scale for measurement.Low Battery. The device will power off in four seconds.Replace all three batteries at the same time. Please purchase the authorized batteries for replacement.Please check below items:-Bluetooth is ON.-App is ON.-Both devices are within the transmission distance of Bluetooth.Failure of pairing up your scale with your smartphone.When Measuring ...TroubleshootingProblem Root Cause SolutionNo display on LCD when the device powers on.The device powers off automatically.Batteries not yet installed.Worn batteries.Low battery.Install the batteries.(Please refer to Insert the Batteries)Replace all three batteries at the same time. Please purchase the authorized batteries for replacement.Replace all three batteries at the same time. Please purchase the authorized batteries for replacement.TroubleshootingProblem Root Cause SolutionBluetooth is OFF.Data transmission failed.Turn ON the Bluetooth via the settings. App is OFF. Press the icon to turn ON your app.Place your smartphone closer to the scale.Out of range of Bluetooth transmission.When Data Transmitting ...Or failure of activation. There has data doesn’t upload. (The notebookicon will be displayed.) Upload the data.
12 13SpecificationsProduct NameDimensionBody Scale (GBS-1269-B)Scale: 280x245x23mm (Approximately)Net Weight Approximately 1.46kg ( Excluding the dry cells)DisplayBlue LCD with White BacklightV.A.: 81x41.6mmMeasurement Unit Kilogram / PoundMeasurement Range 2.5kg to 150kg / 5.6lb to 330lb Division 0.1kg / 0.2lbAccuracy 2.5-100kg: ±0.2kg;Working Environment Temperature: 5  to 40 Humidity: ≤93% RHStorage Environment Temperature: -20  to 60Power Source 4.5V (Three AAA-size Batteries)Auto-ON SENSE ON technologyAuto-OFF About 15 seconds after the weight data is lockedAccessories 1. Three AAA-size Batteries2. User ManualMode of Operation Continuous Operation℃ ℃℃ ℃When carrying out usual maintenance, please ensure practice of the following Do’s and Don’ts:Transtek warrants its products free of defects in materials and workmanship in normal use for a period of FIVE years from the date of retail purchase.This warranty does NOT cover damages caused by misuse or abuse, including but not limited to: Failure caused by unauthorized repairs or modifications;Damage caused by shock or drop during transportation;Failure caused by improper operation inconsistent with the instructions stated in this user manual;Malfunction or damage from failure to provide the recommended maintenance;Damage caused by improper use of power supply.Should this device require maintenance (or replacement at our option) under warranty, please deliver the original package to GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD prepaid. Please return the store receipt (with the retail purchase date) and a note with reasons to return on it as well.MaintenanceWarrantyDO use a dry soft cloth to wipe the dust.DO use a wet soft cloth, dipped into water and wrung out, to wipe the dirt. Then use a dry soft cloth to dry up the device.DON’T wash the device with water or immerse it in water.DON’T use propellant, abrasive or other chemicals to wipe the dirt in avoidance of discolor or malfunction.DON’T disassemble this device. If you have any problems, please contact Transtek. (Please refer to Warranty for contact information)100-150kg: ±0.3kg;About the Accuracy of This ProductThis product passes strict inspection before delivery and therefore its accuracy is guaranteed by the manufacturer. Please refer to the above table for the descriptions on accuracy. WARNING: No modification of this equipment is allowed.Specifications MaintenanceGUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTDZone A, No.105, Dongli Road, Torch Development District, Zhongshan, Guangdong, 528437, ChinaTel: 86-760-88282982Website: http://www.transtek.cn
FCC User Guide InformationRadio Frequency Interface Requirements - FCCNote: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:Reorient or relocate the receiving antenna;Increase the separation between the equipment and receiver;Connect the equipment into an outlet on a circuit different from that to which the receiver is connected;Consult the dealer or an experienced radio / TV technician for help.Radio Transmitters (Part 15)Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.FCC RF Exposure GuidelinesSafety InformationReducing RF Exposure - Use ProperlyOnly operate the device in accordance with the instructions supplied.This device complies with FCC radiation exposure limits set forth for an uncontrolled environment. In order to avoid the possiblity of exceeding the FCC radio frequency exposure limits.FCC RegulationsFCC Regulations14

Navigation menu