Transtek Medical Electronics LS802-E02 Blood Pressure Monitor User Manual

Guangdong Transtek Medical Electronics Co.,Ltd Blood Pressure Monitor Users Manual

Users Manual

Download: Transtek Medical Electronics LS802-E02 Blood Pressure Monitor User Manual
Mirror Download [FCC.gov]Transtek Medical Electronics LS802-E02 Blood Pressure Monitor User Manual
Document ID2413119
Application IDweilgqlja/JDtx9OzHV7Dw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize380.89kB (4761154 bits)
Date Submitted2014-10-08 00:00:00
Date Available2014-10-08 00:00:00
Creation Date2013-09-30 16:04:32
Producing SoftwareAdobe PDF library 9.90
Document Lastmod2014-07-15 17:18:43
Document Titlels802-e(英文)(ok)(20130929)-r3
Document CreatorAdobe Illustrator CS5

Version:1.0
User Manual
Blood Pressure Monitor
LS802-E
Arm Type
FCC ID:OU9LS802-E02
GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO.,LTD
Zone A, 5/F., Investment Building, No. 12, Huizhan East Rd., Torch
Development District, Zhongshan, Guangdong, 528437, China
Thank you very much for selecting TRANSTEK Blood Pressure Monitor
LS802-E.
To use the monitor correctly and safely, please read the manual
thoroughly.
please keep well this manual in order to reference in future.
CATALOGUE
CATALOGUE
Table of Contents
INTRODUCTION ..............................................................................................................................2
General Description
Safety Information
LCD Display Signal
Monitor Components
BEFORE YOU START......................................................................................................................6
The Choice of Power Supply
Installing and Replacing the Batteries
MEASUREMENT..............................................................................................................................8
Tie the Cuff
Start the Measurement
INFORMATION FOR USER ...........................................................................................................10
Tips for measurement
Maintenances
ABOUT BLOOD PRESSURE.........................................................................................................12
What are systolic pressure and diastolic pressure?
What is the standard blood pressure classification?
Why my blood pressure is varies even in one day?
Why the blood pressure I get from the hospital is different from home?
If the result is the same if measuring on the right arm?
TROUBLESHOOTING ...................................................................................................................14
SPECIFICATIONS..........................................................................................................................15
AUTHORIZED COMPONENTS ....................................................................................................16
CONTACT INFORMATION.............................................................................................................16
FCC STATEMENT...........................................................................................................................17
COMPLIED STANDARDS LIST.....................................................................................................18
EMC GUIDANCE............................................................................................................................19
INTRODUCTION
INTRODUCTION
CAUTION
General Description
Thank you for selecting TRANSTEK arm type blood pressure Monitor (LS802-E).
The monitor features blood pressure measurement, pulse rate measurement and the
the result storage. The design provides you with two years of reliable service.
Reading taken by the LS802-E are equivalent to those obtained by a trained
observer using the cuff and stethoscope auscultation method.
This manual contains important safety and care information, and provides step
by step instruction for using the product.
Read the manual thoroughly before using the product.
Features:
92*78mm Blue LCD display with white backlight
Maximum 60 records per each user
Measuring during inflation technology
Safety Information
The below signs might be in the user manual, labeling or other component.
they are the requirement of standard and using.
Symbol for “THE OPERATION
GUIDE MUST BE READ”
Wireless Transmission
F1
Symbol for “TYPE BF APPLIED
PARTS”
Symbol for “MANUFACTURE
DATE”
Symbol for “MANUFACTURER”
Symbol for “DIRECT CURRENT”
Symbol for “SERIAL NUMBER”
Symbol for “Class II Equipment”
For indoor use only
Symbol for “ENVIRONMENT
PROTECTION – Waste electrical
products should not be disposed of
with household waste. Please follow
local guidelines.”
T1A/250V Φ3.6*10CCC
This device is intended for adult use only.
This device is intended for no-invasive measuring and monitoring of arterial blood pressure.
It is not intended for use on extremities other than the arm or for functions other than obtaining a
blood pressure measurement.
Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood
pressure.Do not begin or end medical treatment based solely physician for treatment advice.
If you are taking medication,consult your physician to determine the most appropriate time to
measure your blood pressure. Never change a prescribed medication without consulting your
Physician.
When the device was used to measure patients who have common arrhythmias such as atrial or
ventricular premature beats or artrial fibrillation, the best result may occure deviation. Please
consult your physician about the result.
If the cuff pressure exceeds 40 kPa (300 mmHg), the unit will automatically deflate. Should the
cuff not deflate when pressures exceeds 40 kPa (300 mmHg), detach the cuff from the armand
press the START/STOP button to stop inflation.
The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable
anesthetic mixture with air of with oxygen or nitrous oxide.
The operator shall not touch output of batteries /adapter and the patient simultaneously.
To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated
interference signal or electrical fast transient/burst signal.
The user must check that the equipment functions safely and see that it is in proper working
condition before being used.
This device is contraindicated for any female who may be suspected of, or is pregnant. Besides
provided inaccurate readings, the affects of this device on the fetus are unknown.
Manufacturer will make available on request circuit diagrams, component parts list etc.
This unit is not suitable for continuous monitoring during medical emergencies or operations.
Otherwise, the patient’s arm and fingers will become anaesthetic, swollen and even purple due to
a lack of blood.
Please use the device under the environment which was provided in the user manual. Otherwise,
the performance and lifetime of the device will been impacted and reduced.
During using, the patient will contact with the cuff. The materials of the cuff have been tested and
found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not
cause any potential sensization or irritation reaction.
Please use ACCESSORIES and detachable partes specified/ authorised by MANUFACTURE.
Otherwise, it may cause damage to the unit or danger to the user/patients.
The device doesn’t need to be calibrated in two years of reliable service.
Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the
local guidelines.
If you have any problems with this device, such as setting up, maintaining or using, please
contact with SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself.
Please report to Transtek if any unexpected operation or events occur.
Please use the soft cloth to clean the whole unit. Don’t use any abrasive or volatile cleaners.
The device has been evaluated clinically used manual cuff/stethoscope ausculation as the
reference. Blood pressure measurements determined with this device are equivalent to those
obtained by a trained observer using the cuff/stethoscope auscultatory method, within the limits
prescribed by the American National Standard, Manual, electronic, or automated
sphygmomanometers.”
INTRODUCTION
INTRODUCTION
LCD Display Signal
Monitor Components
CUFF
AIR PIPE
AIR CONNECTOR PLUG
LCD DISPLAY
SYMBOL
DESCRIPTION
EXPLANATION
Systolic blood pressure
High pressure result
DC POWER SOCKET
Diastolic blood pressure Low pressure result
Pulse
Pulse/minute
User 1
Provide measurement for user 1, and
then save the measure data
Guest
Provide measurement for guests,
but not save the measurement data.
User 2
Provide measurement for user 2, and
then save the measure data
Data storage
To remind the users that the measurement
data don’t upload to bridge in time
Wireless transmitter
The blood monitor and Bridge in communication
Network connection
The bridge not connect the network
Shocking remainding
Shocking will result in inaccurate
Low battery
Batteries are low and need to be replaced
Unit
Measurement Unit of the blood pressure
date (hour:minute)
Currently time
Deflating
CUFF air is exhausting of deflating
Arrhythmia
Irregular heartbeat
Heartbeat
Heartbeat detection during the measurement
User 2
Guest
User 1
Component list of
pressure measuring system
1 Cuff
2 Air pipe
3 PCBA
4 Pump
5 Valve
BATTERY COMPARTMENT
List
1.Blood Pressure Monitor
(LS802-E)
2.Cuff (Type BF applied part)
3. 4*AA alkaline batteries
4.User manual
(22~32cm or 22cm~42cm)
5. AC Adaptor
(UE08WCP-060100SPA only!)
BEFORE YOU START
MEASUREMENT
The Choice of Power Supply
Tie the Cuff
1.Battery powered mode:
6VDC 4*AA alkaline batteries
1.Tie the cuff on your upper arm,
the position the tube off-center
toward the inner side of arm in
line with the little finger.
2.AC adaptor powered mode:
100-240V~, 50-60HZ,400mA
(Can be supplied by AC adaptor model
UE08WCP-060100SPA only!)
Please unplug the adaptor to depart from
the using utility power.
Note:
The adaptor interface is located on the right side of the monitor.
Place NO obstacles on the right for easy pull-off adaptor.
AC adaptor
CAUTION
In order to get the best effect and protect you monitor,please use the right
battery and special power adapter which complies with U.S. safety standard.
Installing and Replacing the Batteries
1.Slide off the battery cover.
2.Install the batteries by matching
the correct polarity, as shown.
3.Replace the cover.
Replace the batteries whenever the below happen
The
shows
The display dims
The display does not light up
CAUTION
Remove batteries if the device is not likely to be used for some time.
The old battery is harmful to the environment, so please disposal with other daily trash.
Remove the old battery from the device and follow your local recycling guidelines.
Do not dispose of batteries in fire. Batteries may explode or leak.
2.The cuff should be sung but not
too tight. You should be able to
insert one finger between the
cuff and your arm.
3.Sit comfortably with your tested
arm resting on a flat surface.
4.Correct Posture for Patients with
Hypertension, especially for
Hypertension patient
- Bare your arm or wear tights only
when starting measurement.
- Sit comfortably with legs
uncrossed, feet flat on the floor,
back and arm supported.
The central of the cuff should
maintain at the same level as the
right atrium of the heart.
2~3cm
Resting for 5 minutes before
measuring.
Wait at least 3 minutes between
measurements. This allows your
blood circulation to recover.
For a meaningful comparison,
try to measure under similar
conditions. For example, take daily
measurements at approximately
the same time, on the same arm,
or as directed by a physician.
MEASUREMENT
MEASUREMENT
Start the Measurement
Press the User 1 button to turn on the monitor and it will finish the
whole measurement, and then save the measure data for User 1. The
same to the User 2.
Press the Guest button to turn on the monitor and it will finish the whole
measurement for Guest, but not save the measurement data.
In this manual, the measurement of User 1 as an example.
1. When the monitor is off,
press the User 1 button to turn on the monitor.
Adjust the zero . If the
measure data don’t upload to
the bridge in time, the icon
LCD display
When there is
will display.
no record
3 Please proceed to activate/synchronize before initial use of this equipment or when
the measurement unit is changed. When the equipment is OFF, press and hold
“GUEST” button to enter Activation / Synchronization Interface. After successful
activation/synchronization, the equipment will display and transmit the measuring
results after each measurement.
Activation
/synchroniz
ation is
proceeding
Wireless Transmission
AW4431_915
Module No.
Frequency Range
The
measureme
-nt data is
uploading
Supply Voltage
915 - 918.5 MHz Output Power Range
The data
has been
uploaded
successfully
3.3V
+1 dBm
CAUTION
Inflating and measuring.
Display and save the results will
transmit to the bridge through the
wireless.
Interference may occur in the vicinity of equipment marked with the following symbol
. And LS802-E may interfering vicinity electrical equipment.
Sensitive people, including pregnant women and those who implanted medical electronic instruments, should avoid using the unit whenever possible.
Keep the monitor at least 20 centimeters away from the human body (especially the
head) when the data transmission is proceeding after measurement.
To enable the data transmission function, this product should be interconnected with
Bridge in RF 915 MHz network.
How to mitigate possible interference?
2. Press the User 1 to power off , otherwise it
will turn off within one minute.
Tips:
A.when finish the whole measurement, press another button ,the blood
monitor will begin measure again.
B.If the blood monitor not connect with bridge, the icon of
will display.
Maximum 60 records are both for User 1 and User 2.
1. The range between the device and the Bridge should be reasonably close, from 1
meter to 10 meters. Please ensure no obstacles between the device and the Bridge
so as to obtain quality connection and to lower the RF output range.
2. To avoid interference, other electronic devices (particularly those with wireless
transmission / Transmitter) should be kept at least 1 meter away from the monitor.
INFORMATION FOR USER
INFORMATION FOR USER
Tips for measurement
It can cause incorrectness if the measurement are taken in the
following circumstances.
10
Within 1 hour
after dinner or drinking
Immediate measurement
after tea, coffee, smoking
Within 20 minutes
after taking a bath
When talking or moving your fingers
In a very cold environment
When you want to discharge urine
Maintenance
In order to get the best performance, please follow the below
instructions.
Put in a dry place and avoid the sunshine
Avoid touching water,
clean it with a dry cloth in case.
Avoid the intense shaking
and collision
Avoid the dusty and unstabletemperature environment
Using the wet clothing to remove the dirt
Avoid washing the cuff
11
ABOUT BLOOD PRESSURE
ABOUT BLOOD PRESSURE
What are systolic pressure and diastolic
pressure?
When ventricles contract and pump blood
out of the heart, blood pressure reaches its
maximum value, the highest pressure in the
cycle is known as systolic pressure. When
the heart relaxes between heartbeats, the
lowest blood pressure is diastolic pressure.
Systolic
blood discharging
artery
Diastolic
blood entering
vein
press
relax
What is the standard blood pressure
classification?
This chart reflects blood pressure categories defined by American Heart Association.
The chart on the right is the standard
blood pressure classification published
by American Heart Association (AHA).
AHA Home Guideline for
Upper Limit of Normal BP
SYS 135 mm Hg
DIA 85 mm Hg
Blood Pressure Category
Systolic
mmHg (upper#)
Diastolic
mmHg (lower#)
less than 120
and
less than 80
Prehypertension
120-139
or
80-89
High Blood Pressure
(Hypertension) Stage 1
140-159
or
90-99
160 or higher
or
100 or higher
Higher than 180
or
Normal
High Blood Pressure
(Hypertension) Stage 2
Hypertensive Crisis
(Emergency care needed)
Higher than 110
CAUTION
Only a physician can tell your normal BP range. Please contact a physician if your
measuring result falls out of the range. Kindly note that only a physician could tell whether
your blood pressure value has reached a dangerous point.
Irregular Heartbeat Detector
This Blood Pressure Monitor is equipped with an intelligent function of Irregular Heartbeat
(IHB) Detector. During each measurement, this equipment records the heartbeat intervals and
works out the standard deviation. If the calculated value is larger than or equal to 15, this
equipment will light up the IHB symbol on the screen when displaying the measuring result.
CAUTION
12
The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular
heartbeat was detected during measurement. Usually this is NOT a cause for concern.
However, if the symbol appears often, we recommend you seek medical advice. Please note
that the device does not replace a cardiac examination, but serves to detect pulse irregularities
at an early stage.
Why does my blood
pressure fluctuate
throughout the day?
1. Individual blood pressure varies
every in one day, it also affected by the
way you tie your cuff and the your
measurement position, so please take
the measurement at the same condition.
2.The varies of the pressure is
greater if the person take medicine.
3.Waiting at least 3 minutes for
another measurement.
Why the blood pressure
I get from the hospital
is different from home?
The blood pressure is different even
during 24 hour because of the
weather,emotion, exercise etc,
specially the “white coat” in hospital
which makes the results are higher
than the ones at home.
The attention need to pay
when you measure you blood
pressure at home:
If the cuff is tied properly.
If the cuff is too tight or too loose.
If the cuff is tied on the upper arm.
If you feel anxious pressured.
You had better take deep breath 2-3
times before beginning.
Advice:adjust yourself for 4-5
minutes until you calm down.
If the result is the same
if measuring on the
right arm?
It is ok for both arms, but there
will be some different results for
different arm, so suggest you
measure the same arm every time.
13
TROUBLESHOOTING
SPECIFICATIONS
This section includes a list of error messages and frequently
asked questions for problems you may encounter with your blood
pressure monitor. If the products not operating as you think it
should, check here before arranging for servicing.
PROBLEM SYMPTOM
No power
Low
batteries
Display will not
light up.
AC adaptor is inserted
incorrectly.
Insert the AC adaptor
tightly
Display is dim
or show
Batteries are low.
Replace with new batteries
E 1 shows
Check the database is
RF communication failed. power on or not.
E 9 shows
E10 or E11
shows
E20 shows
E21 shows
Exxx,shows on
the display.
14
Batteries are exhausted. Replace with new batteries
Insert the batteries
correctly
E 8 shows
Or synchronize the data
operation.
Refasten the cuff and then
The cuff is not secure.
measure again.
Failure of activating or
Check if the newwork is
synchronizing the network connected normally or not.
Activate or register the
The device is not
activated or registered. device again.
The monitor detected
Relax for a
moment and then
motion,talking or the
measure again.
pluse is too poor
while measuring.
The measurement
Loosen the clothing on the
process does not detect arm and then measure
the pulse signal.
again
The treatment of the
measurement failed.
A calibration error
occurred.
Display mode
Digital LCD V.A.78*92mm
Measurement mode
Oscillographic testing mode
Measurement range
Rated cuff pressure:
0kpa - 40kpa (0mmHg~300mmHg)
Measurement pressure: 5.3kPa-30.7kPa
(40mmHg-230mmHg)
pulse value: (40-199) beat/minute
REMEDY
Batteries are inserted
incorrectly.
E 3 shows
Error
massage
CHECK THIS
Power supply
Battery powered mode:
6VDC 4*AA alkaline batteries
AC adaptor powered mode:
100-240V~, 50-60HZ,400mA
(Can be supplied by AC adaptor model
UE08WCP-060100SPA only!)
Relax for a moment and
then measure again.
Retake the measurement.
If the problem persists,
contact the retailer or our
customer service
department for further
assistance.Refer to the
warranty for contact
information and return
instructions.
Accuracy
Pressure:
5℃-40℃within±0.4kpa(3mmHg)
pulse value:±5%
Normal working condition
Temperature:5℃ to 40℃ Relative humidity ≤85%
Atmospheric pressure: 86kPa to 106kPa
Storage & transportation
condition
Temperature:-20℃-60℃
Relative Humidity 10%-93%
Atmospheric Pressure: 50-106 kPa
Measurement perimeter
of the upper arm
Net Weight
External dimensions
Attachment
About 22cm~32cm or 22cm~42cm
Approx.385g(Excluding the dry cells)
Approx.120*160*69mm
4*AA alkaline batteries,user manual
Mode of operation
Continuous operation
Degree of protection
Type BF applied part
Protection against
ingress of water
IP21
Device Classification
Battery powered mode: Internally powered ME Equipment
Software Version
V01
AC adaptor powered mode: CLASS II ME Euipment
15
FCC STATEMENT
AUTHORIZED COMPONENTS
Authorized Components
1.Please use the TRANSTEK
authorized adaptor.
2.Storage bag.
Adaptor
Type:UE08WCP-060100SPA
Input:100~240V,50~60Hz,400mA
Output:6V
1A
(Conforms to UL certificate)
Contact Information
For more information about our products, please visit www.transtek.cn.you can get
customer service, usual problems and customer download, transtek will serve you
anytime.
Manufactured by: GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Company: GUANGDONG TRANSTEK MEDICAL ELECTRONICS CO., LTD
Address: Zone A, 5/F., Investment Building , No. 12, Huizhan East Rd., Torch
Development District, Zhongshan, Guangdong, 528437, China
FCC Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
Caution: The user is cautioned that changes or modifications not expressly
approved by the party responsible for compliance could void the user’s authority
to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for
a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
16
17
EMC GUIDANCE
COMPLIED STANDARDS LIST
Complied Standards list
Risk management
ISO/EN 14971:2012 Medical devices — Application of risk
management to medical devices
Labeling
ISO/EN 15223-1:2012 Medical devices. Symbols to be
used with medical device labels, labelling and information to
be supplied. General requirements
User manual
EN 1041: 2008 Medical equipment manufacturers to
provide information
General
Requirements for
Safety
18
IEC 60601-1: 2005+A1:2012 Medical electrical
equipment - Part 1: General requirements for basic safety and
essential performance
Electromagnetic
compatibility
IEC/EN 60601-1-2:2007 Medical electrical equipment Part 1-2: General requirements for basic safety and essential
performance - Collateral standard:Electromagnetic
compatibility - Requirements and tests
Performance
requirements and
Clinical Investigation
IEC 80601-2-30:2009 Medical electrical equipment- Part
2-30: Particular requirements for the basic safety and
essential performance of automated non-invasive
sphygmomanometers
ANSI/AAMI SP10:2002/A2: 2008 Manual, electronic, or
automated sphygmomanometers
Software life-cycle
processes
IEC/EN 62304:2006+AC: 2008 Medical device software
- Software life cycle processes
EMC Guidance
1. MEDICAL ELECTRICAL EQUIPMENT needs special precautions
regarding EMC and needs to be installed and put into service according to
the EMC information provided in the ACCOMPANYING DOCUMENTS
2. Wireless communications equipment such as wireless home network
devices, mobile phones, cordless telephones and their base stations,
walkie-talkies can affect this equipment and should be kept at least a
distance d=3, 3m away from the equipment.
(Note: As indicated in Table 6 of IEC 60601-1-2:2007 for ME
EQUIPMENT, a typical cell phone with a maximum output power of 2 W
yields d=3, 3m at an IMMUNITY LEVEL of 3V/m)
19

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 5.0-c060 61.134777, 2010/02/12-17:32:00
Format                          : application/pdf
Title                           : ls802-e(英文)(ok)(20130929)-r3
Creator Tool                    : Adobe Illustrator CS5
Create Date                     : 2013:09:30 16:04:32+08:00
Modify Date                     : 2014:07:15 17:18:43+08:00
Metadata Date                   : 2014:07:15 17:18:43+08:00
Thumbnail Width                 : 36
Thumbnail Height                : 256
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 2600 bytes, use -b option to extract)
Original Document ID            : uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7
Document ID                     : xmp.did:9FA8AEA89F29E311A4DED438AC7AF162
Instance ID                     : uuid:593cc5bf-cbc0-472f-9802-edce53c81f8b
Rendition Class                 : proof:pdf
History Action                  : converted, saved, converted, converted, saved, converted, saved, converted, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:D07F11740720681191099C3B601C4548, xmp.iid:FC7F117407206811B628E3BF27C8C41B, xmp.iid:FD7F117407206811B628E3BF27C8C41B, xmp.iid:0CC3BD25102DDD1181B594070CEB88D9, xmp.iid:03E540664A3DDD11BD33D3EB8D3A1068, xmp.iid:6D6AE2A5723EDD11A6F1BABF7C5A7A51, xmp.iid:20383BFEA441DD11A6AECB58D53C8B28, xmp.iid:096F577ABE41DD11A6AECB58D53C8B28, xmp.iid:AB13E990200911689FE8CB9EA85C5459, xmp.iid:95D9A2DF7848DD11BB47877F8DDF9079, xmp.iid:F87F117407206811B34B80FC905F8DB1, xmp.iid:FE7F11740720681197A5C6DA8C2593EE, xmp.iid:FF7F11740720681197A5C6DA8C2593EE, xmp.iid:D5E97F3291E4DE11831BCC4BA24AAFD8, xmp.iid:3E09327B1FEADE119648D46DE661B201, xmp.iid:A8F46C6799EBDE118B29BF0F76361FFD, xmp.iid:233794C82A12DF11A1FB8DE093AEEF16, xmp.iid:E9171D43F3ABDF119F67BD126A85E7C0, xmp.iid:ED171D43F3ABDF119F67BD126A85E7C0, xmp.iid:C5BED870236AE011942DE749A5493887, xmp.iid:74B7070D93CCE0119B0B8E22D6A53FC0, xmp.iid:58DFB001E4E1E1119A52E97546EC47AF, xmp.iid:9FA8AEA89F29E311A4DED438AC7AF162
History When                    : 2008:04:17 14:19:10+05:30, 2008:05:22 14:51:08-07:00, 2008:05:22 15:15:38-07:00, 2008:05:28 17:07:17-07:00, 2008:06:18 22:24:35+07:00, 2008:06:19 20:31:09-07:00, 2008:06:24 13:29:32+08:00, 2008:06:24 15:24:18+08:00, 2008:06:26 06:04:07-07:00, 2008:07:02 13:54:46-07:00, 2008:07:21 16:58:27+05:30, 2008:09:05 04:29:47-07:00, 2008:09:05 04:30:01-07:00, 2009:12:09 17:43:05+08:00, 2009:12:16 16:46:19+08:00, 2009:12:18 17:47:07+08:00, 2010:02:05 15:48+08:00, 2010:08:20 08:39:57+08:00, 2010:08:20 12:32:03+08:00, 2011:04:19 09:22:07+08:00, 2011:08:22 15:48:49+08:00, 2012:08:09 13:56:20+08:00, 2013:09:30 16:04:23+08:00
History Software Agent          : Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS4, Adobe Illustrator CS5, Adobe Illustrator CS5, Adobe Illustrator CS5
History Changed                 : /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /
History Params                  : from application/vnd.adobe.illustrator to application/vnd.adobe.illustrator
Derived From Instance ID        : uuid:5ed1836e-5ae4-441f-94b0-c342e76b14a2
Derived From Document ID        : xmp.did:58DFB001E4E1E1119A52E97546EC47AF
Derived From Original Document ID: uuid:9E3E5C9A8C81DB118734DB58FDDE4BA7
Derived From Rendition Class    : proof:pdf
Manifest Link Form              : EmbedByReference
Manifest Reference File Path    : E:\血压计\bag\DSC03519副本.jpg
Startup Profile                 : Basic RGB
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : False
Max Page Size W                 : 25.700016
Max Page Size H                 : 18.200026
Max Page Size Unit              : Centimeters
Font Name                       : Arial-BoldMT, ArialMT, Arial-Black, TimesNewRomanPSMT, FZDHTJW--GB1-0, AdobeSongStd-Light, SimSun, SimHei
Font Family                     : Arial, Arial, Arial, Times New Roman, 方正大黑简体, Adobe 宋体 Std, 宋体, 黑体
Font Face                       : Bold, Regular, Black, Regular, Regular, L, Regular, Regular
Font Type                       : Open Type, Open Type, Open Type, Open Type, TrueType, Open Type, TrueType, TrueType
Font Version                    : Version 3.00, Version 3.00, Version 2.40, Version 3.00, 1.00, Version 5.002;PS 5.002;hotconv 1.0.49;makeotf.lib2.0.15106, Version 3.12, Version 3.02
Font Composite                  : False, False, False, False, False, False, False, False
Font File Name                  : ARIALBD.TTF, ARIAL.TTF, ariblk.TTF, TIMES.TTF, fzdhtjw.TTF, AdobeSongStd-Light.otf, simsun.ttc, simhei.ttf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE Reflex Blue C
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Group Name        : 初始屏幕
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: R=180 G=58 B=228
Swatch Groups Colorants Mode    : CMYK
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Cyan    : 48.046899
Swatch Groups Colorants Magenta : 78.906298
Swatch Groups Colorants Yellow  : 0.000000
Swatch Groups Colorants Black   : 0.000000
Producer                        : Adobe PDF library 9.90
Page Count                      : 11
Creator                         : Adobe Illustrator CS5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: OU9LS802-E02

Navigation menu