User ManualBlood Pressure Monitor TMB-1490-BSArm TypeThank you very much for selecting TRANSTEK Blood Pressure MonitorTMB-1490-BS.Please do read the user manual carefully and thoroughtly so as to ensure the safe usage of this product, and keep the manual well for further reference in case you have problems.version:1.0FCC ID:OU9TMB1490BSGuangdong Transtek Medical Electronics Co., Ltd.Zone B, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China  Document No.: LS-INS-TMB-1490-BS-2Version: A0
INTRODUCTION..................................................................................................................2General DescriptionIndications for UseSafety InformationLCD Display SignalMonitor ComponentsList BEFORE YOU START..........................................................................................................8The Choice of Power SupplyInstalling and Replacing the BatteriesMeasurement PrincipleSetting Date, Time and Measurement UnitMEASUREMENT................................................................................................................12Tie the CuffStart the MeasurementDATA MANAGEMENT........................................................................................................15Recall the RecordsDelete the RecordsINFORMATION FOR USER...............................................................................................17Tips for measurementMaintenancesABOUT BLOOD PRESSURE.............................................................................................19What are systolic pressure and diastolic pressure?What is the standard blood pressure classification?Irregular heartbeat detectorWhy does my blood pressure fluctuate throughout the day?Why do I get a different blood pressure at home compared to the hospital?Is the result the same if measuring on the right arm?TROUBLESHOOTING.......................................................................................................21SPECIFICATIONS..............................................................................................................22AUTHORIZED COMPONENT ...........................................................................................23CONTACT INFORMATION.................................................................................................23FCC STATEMENT...............................................................................................................24COMPLIED STANDARDS LIST..........................................................................................25EMC GUIDANCE................................................................................................................26Table of ContentsCATALOGUEContraindications
 Thank you for selecting TRANSTEK arm type blood pressure monitor (TMB-1490-BS). The monitor features blood pressure measurement, pulse  rate measurement and the result storage. The design provides you with  two years of reliable service. Readings taken by the TMB-1490-BS are equivalent to those obtained by  a trained observer using the cuff and stethoscope auscultation method.This manual contains important safety and care information, and provides step by step instructions for using the product.Read the manual thoroughly before using the product.Features: Maximum 250 records per each userGeneral Description3rd technonoly: Measuring during inflation (The updated technology in the world)60.5 mm×92.5 mm Digital LCD displayINTRODUCTION INTRODUCTIONIndications for Use    The Transtek Blood Pressure Monitor is digital monitors intended for use in measuring blood pressure and heartbeat rate with arm circumference ranging IURPFPWRFPDERXWôÝòÝRUFPWRFPDERXWôÝòÝIt is intended for adult indoor use only.* Be careful to strangulation due to cables and hoses, particularly due to excessive length.* At least 30 min required for ME equipment to warm from the minimum storage temperature between uses until it is ready for intended use. At least 30 min required for ME equipment to cool from the maximum storage temperature between uses until it is ready for intended use.* This equipment needs to be installed and put into service in accordance with the information provided in the ACCOMPANYING DOCUMENTS;* Wireless communications equipment such as wireless home network devices, mobile phones, cordlesstelephones and their base stations, walkie-talkies can affect this equipment and should be kept at least adistance d away from the equipment. The distance d is calculated by the MANUFACTURER from the 80MHz to 5.8 GHz column of Table 4 and Table 9 of IEC 60601-1-2:2014, as appropriate.* Please use ACCESSORIES and detachable partes specified/ authorised by MANUFACTURE. Otherwise, it may cause damage to the unit or danger to the user/patients.* There is no luer lock connectors are used in the construction of tubing, there is a possibility that they might be inadvertently connected to intravascular fluid systems, allowing air to be pumped into a blood vessel.* Please use the device under the environment which was provided in the user manual. Otherwise, the performance and lifetime of the device will be impacted and reduced.CAUTIONSafety InformationThe signs below might be in the user manual, labeling or other component. They are the requirement of standard and using.Symbol for “THE OPERATION GUIDE MUST BE READ”Symbol for “MANUFACTURER”Symbol for “SERIAL NUMBER”Symbol for “TYPE BF APPLIED PARTS”Symbol for “DIRECT CURRENT”Symbol for “ENVIRONMENT PROTECTION - Electrical waste products should not be disposed of with household waste. Please recycle where facilities exist. Check with your local authority or retailer for recycling advice”Symbol for “MANUFACTURE DATE”For indoor use onlyF17$9ĭ&&&Symbol for “Class II Equipment”Caution: These notes must be observed to prevent any damage to the device.SNThe Green Dot is the license symbol of a European network of industry-funded systems for recycling the packaging materials of consumer goods.Symbol for “Recycle”1.The device is not suitable for use on may be pregnant women or pregnant women.2.The device is not suitable for use on patients with implanted,electrical devices,such as cardiac pacemakers, defibrillators.Contraindications
 CAUTION* This device is intended for adult use in homes only. * The device is not suitable for use on neonatal patients, pregnant women,patients with implanted, electronical devices, patients with pre-eclampsia, premature ventricular beats, atrial fibrillation, peripheral, arterial disease and patients undergoing intravascular therapy or arterio-venous shunt or people who received a mastectomy. Please consult your doctor prior to using the unit if you suffer from illnesses.* The device is not suitable for measuring the blood pressure of children. Ask your doctor before using it on older children.* The device is not intended for patient transport outside a healthcare facility.* The device is not intended for public use.* This device is intended for no-invasive measuring and monitoring of arterial blood pressure.It is not intended for use on extremities other than the arm or for functions other than obtaining a blood pressure measurement.* Do not confuse self-monitoring with self-diagnosis. This unit allows you to monitor your blood pressure.Do not begin or end medical treatment without asking a physician for treatment advice.* If you are taking medication,consult your physician to determine the most appropriate time to measure your blood pressure. Never change a prescribed medication without consulting your physician.* Do not take any therapeutic measures on the basis of a self measurement. Never alter the dose of a medicine prescribed by a doctor. Consult your doctor if you have any question about your blood pressure.* When the device was used to measure patients who have common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, the best result may occur with deviation. Please consult your physician about the result.* Don't kink the connection tube during use, otherwise, the cuff pressure may continuously increase which can prevent blood flow and result in harmful injury to the PATIENT.* When using this device, please pay attention to the following situation which may interrupt blood flow and influence blood circulation of the patient, thus cause harmful injury to the patient: connection tubing kinking too frequent and consecutive multiple measurements; the application of the cuff and its pressurization on any arm where intravascular access or therapy, or an arterio-venous (A-V) shunt, is present; inflating the cuff on the side of a mastectomy.* Warning: Do not apply the cuff over a wound;otherwise it can cause further injury.*Do not inflate the cuff on the same limb which other monitoring ME equipment is applied around simultaneously, because this could cause temporary loss of function of those simultaneously-used monitoring ME equipment.*On the rare occasion of a fault causing the cuff to remain fully inflated during measurement, open the cuff immediately. Prolonged high pressure (cuff pressure > 300mmHg or constant pressure > 15mmHg for more than 3 minutes) applied to the arm may lead to an ecchymosis.*Please check that operation of the device does not result in prolonged impairment of patient blood circulation.* When measurement, please avoid compression or restriction of the connection tubing.* The device cannot be used with HF surgical equipment at the same time.* The ACCOMPANYING DOCUMENT shall disclose that the SPHYGMOMANOMETER was clinically investigated according to the requirements of ISO 81060-2:2013.* To verify the calibration of the AUTOMATED SPHYGMOMANOMETER, please contact the manufacturer.* This device is contraindicated for any female who may be suspected of, or is pregnant. Besides providing inaccurate readings, the effects of this device on the fetus are unknown.* Too frequent and consecutive measurements could cause disturbances in blood circulation and injuries.* This unit is not suitable for continuous monitoring during medical emergencies or operations.Otherwise, the patient’s arm and fingers will become anaesthetic, swollen and even purple due to a lack of blood.* When not in use, store the device with the adapter in a dry room and protect it against extreme moisture, heat, lint, dust and direct sunlight. Never place any heavy objects on the storage case.* This device may be used only for the purpose described in this booklet. The manufacturer cannot be held liable for damage caused by incorrect application.*This device comprises sensitive components and must be treated with caution. Observe the storage and operating conditions described in this booklet.CAUTION* The equipment is not AP/APG equipment and not suitable for use in the presence of a flammable anesthetic mixture with air of with oxygen or nitrous oxide.* Warning: No servicing/maintenance while the ME equipment is in use.* The patient is an intended operator.* The patient can measure, transmit data and change batteries under normal circumstances and maintain the device and its accessories according to the user manual.* To avoid measurement errors, please avoid the condition of strong electromagnetic field radiated interference signal or electrical fast transient/burst signal.*The blood pressure monitor, its adaptor, and the cuff are suitable for use within the patient environment. If you are allergic to polyester, nylon or plastic, please don't use this device. * During use, the patient will be in contact with the cuff. The materials of the cuff have been tested and found to comply with requirements of ISO 10993-5:2009 and ISO 10993-10:2010. It will not cause any potential sensization or irritation reaction.* Adaptor is specified as a part of ME EQUIPMENT.* If you experience discomfort during a measurement, such as pain in the arm or other complaints, press the START/STOP button to release the air immediately from the cuff. Loosen the cuff and remove it from your arm.* If the cuff pressure reaches 40 kPa (300 mmHg), the unit will automatically deflate. Should the cuff not deflate when pressures reaches 40 kPa (300 mmHg), detach the cuff from the arm and press the START/STOP button to stop inflation.* Before use, make sure the device functions safely and is in proper working condition. Check the device, do not use the device if it is damaged in any way. The continuous use of a damaged unit may cause injury, improper results, or serious danger.* Do not wash the cuff in a washing machine or dishwasher!* The service life of the cuff may vary by the frequency of washing, skin condition, and storage state. The typical service life is 10000 times.* It is recommended that the performance should be checked every 2 years and after maintenance and repair, by retesting at least the requirements in limits of the error of the cuff pressure indication and air leakage (testing at least at 50mmHg and 200mmHg).* Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT according to the local guidelines.* Manufacturer will make available on request circuit diagrams, component part lists, descriptions, calibration instructions,etc., to assist to service personnel in parts repair.* The plug/adapter plug pins insulates the device from the main supply. Do not position the device in a position where it is difficult to disconnect from the supply mains to safely terminate operation of ME equipment.* The operator shall not touch output of batteries /adapter and the patient simultaneously.* Cleaning :Dust environment may affect the performance of the unit. Please use the soft cloth to clean the whole unit before and after use. Don’t use any abrasive or volatile cleaners.* The device doesn’t need to be calibrated within two years of reliable service.* If you have any problems with this device, such as setting up, maintaining or using, please contact the SERVICE PERSONNEL of Transtek. Don’t open or repair the device by yourself in the event of malfunctions. The device must only be serviced, repaired and opened by individuals at authorized sales/service centers.* Please report to Transtek if any unexpected operation or events occur.* Keep the unit out of reach of infants, young children or pets to avoid inhalation or swallowing of small parts. It is dangerous or even fatal.INTRODUCTIONINTRODUCTION
Pul/minMEMORYTIME /DATESMSTARTSTOP(1mmHg=0.133kPa)(1kPa=7.5mmHg)LCD display signalSYMBOL DESCRIPTIONSystolic blood pressure High blood pressure Diastolic blood pressure Low blood pressureEXPLANATIONMemorymmHgkPaMeasurement Unit of the blood pressureMeasurement Unit of the blood pressureLow battery Batteries are low and need to be replacedkPammHgCurrent Time Month/Day/Year, Hour/MinutePul/minUser AStart measurement,save and transmit the measuring results for User AUser BStart measurement,save and transmit the measuring results for User BHeartbeatINTRODUCTIONMonitor ComponentsList1.Blood Pressure Monitor  (TMB-1490-BS)4.User manual2.Cuff  (Type BF applied part)                (22cm~32cm or 22cm~42cm)Component list of pressure measuring system1 Cuff 2 Air pipe3 PCBA4 Pump5 Valve3. 4×AAA  batteriesBATTERY COMPARTMENTCUFF AIR HOSEAIR CONNECTOR PLUGLCD DISPLAYMEM BUTTON67$576723%87721SET BUTTONINTRODUCTIONUSER SWITCHThe average value The average value of the latest three recordsBluetooth icon The bluetooth icon blinks when the bluetooth is working5. AC Adaptor(BLJ06L060100P-U)Pulse in beats per minutePulse displayDeflation symbol The cuff is deflating.Indicate it is in the memory mode and which group of memory it is.Blood pressure monitor is detecting an irregular heartbeat during measurement.Irregular heartbeatBlood pressure level indicator Indicate the blood pressure levelBlood pressure monitor is detecting a heartbeat during measurement.DC POWER SOCKET
Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPIn order to get the best effect and protect your monitor,please use the the right batteries and special power adapter which complies with local safety standard.Open the battery cover.Install the batteries by matching the correct polarity, as shown.Replace the battery cover.Installing and Replacing the BatteriesCAUTIONCAUTIONReplace the batteries whenever the below happenThe                     showsThe display is dim.The display does not light up AC adaptorThe Choice of Power Supply1.Battery powered mode:    6VDC 4×AAA batteries2.AC adaptor powered mode:(Please only use the recommended  AC adaptor model). Please unplug the adaptor to depart fromthe using utility power.BEFORE YOU STARTMeasurement PrincipleSetting Date, Time and Measurement Unit  It is important to set the clock before using your blood pressure monitor, so that a time stamp can be assigned to each record that   is stored in the memory. (The setting range of the year :2017—2057time format:12 H/24H)This product uses the Oscillometric Measuring method to detect blood pressure.  Before every measurement, the unit establishes a “zero pressure” equivalent to the air pressure. Then it starts inflating the arm cuff, meanwhile, the unit detects pressure oscillations generated by beat-to-beat pulsatile, which is used to determine the systolic and diastolic pressure, and also pulse rate.1.When the monitor is off, press “SET”button,it will display the time.Then press and hold “ SET ” button to enter the mode for year setting. 2.Press the “MEM” to change the [YEAR]. Each press will increase the numeral by one in a cycling manner.BEFORE YOU START   6V     1ADo not use new and used batteries together. Do not use different types of batteries together.Do not dispose the batteries in fire. Batteries may explode or leak.Remove batteries if the device is not likely to be used for some time.Worn batteries are harmful to the environment. Do not dispose with daily garbage.Remove the old batteries from the device following your local recycling guidelines.
Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPBEFORE YOU START BEFORE YOU START3.When you get the right year, press “SET” to set down and turn to next step.4.Repeat steps 2 and 3 to set the [MONTH] and [DAY].5.Repeat steps 2 and 3 to set the [TIME FORMAT] between 12h and 24h. 6.Repeat steps 2 and 3 to set the [HOUR] and [MINUTE].8.After the unit is set,the LCD will display“dOnE”first,then display all the settings you have done and then it will turn off.7.Repeat steps 2 and 3 to set the [UNIT].Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOP
Pul/minMEMORYTIME /DATESMSTARTSTOPMEASUREMENTTie the cuff1.Before you start the measurement, switch the User button to select the user between User A and User B. Switch to right to select User A, switch to left toVHOHFW8VHU%:KHQWKHPRQLWRULVRIISUHVVWKH³67$576723EXWWRQWRWXUQon the monitor, and it will finish the whole measurement,save and transmit themeasurement data for the desired user. (Take User A for example.)Adjust the zero. LCD displayInflating and measuring.  Display and save themeasurement result. Start the MeasurementMEASUREMENT2~3cm1.4.Hold your arm with your palm facing up and tie the cuff on your upper arm, then position the tube off-center toward the inner side of arm in line with the little finger. Or position the artery mark      over  the main artery (on the inside of your arm).  Note: Locate the main artery by pressing with 2 fingers approximately 2 cm above the bend of your elbow on the inside of your left arm. Identify where the pulse can be felt the strongest. This is your main artery.The cuff should be snug but not too tight. You should be able to insert one finger between the cuff and your arm.Remove all jewelry, such as watches and bracelets from your left arm.Note: If your doctor has diagnosed you with poor circulation in your left arm, use your right arm.Roll or push up your sleeve to expose the skin. Make sure your sleeve is not too tight.2.3.5. Sit comfortably with your tested arm resting on a flat surface. Place your elbow on a table so that the cuff is at the same level as your heart. Turn your palm upwards. Sit upright in a chair, and take 5-6 deep breaths.Rest for 5 minutes before first measuring.Wait at least 3 minutes between measurements. This allows your blood circulation to recover.The patient must relax as much as possible and do not move and talk during the measurement procedure.For a meaningful comparison, try to measure under similar conditions. For example, take daily measurements at approximately the same time, on the same arm, or as directed by a physician.6.Take the measurement in a silent room.The cuff should maintain at the same level as the right atrium of the heart.Please sit comfortably. Do not cross your legs and keep your feet flat on the ground.Keep your back against the backrest of the chair.Helpful tips for Patients, especially for Patients with Hypertension:Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPBluetooth Module No.: LS51802RF Frequency Range: 2402 MHz to 2480 MHzOutput Power Range: 0 dBm    Supply Voltage: 2V-3.6 VTransmitting Distance: 10 metersList of compatible devices:For iOS devices:The operating system must be iOS 8 or more, such as iPhone4S, iPhone 5/5C/5S, iPhone 6/6 Plus and so on.For Android devices:The operating system must be 4.3 or more.
Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPMEASUREMENTSTARTSTOP43UHVVWKH³67$576723´WRSRZHUoff.Tips: Maximum 250 records are both for User A and User B.Recall the Records2. Press the “MEM” or “SET” to get the record youwant. The most recent record (1) is shown first.  Each new measurement is assigned to the first (1) record. All other records are pushed back one digit (e.g., 2 becomes 3, and so on), and the last record (60) is dropped from the list.The current No. is No 2. The corresponding time is P.M. 10:08.The corresponding date is January 6th.CAUTIONThe date and time of the record will be shown alternately.DATA MANAGEMENT3. If you want to look over another user’s data, switch the User button to select the desired user. Then you can look over its historical records. 1. When the monitor is off, please press the “MEM”,it will display the  latest record first when the records are less thanthree groups. When there are three or more than three groups ,it will display the average value of the latest three records first.2.This device will proceedto data transmissionafter measurement.The Bluetooth symbolblinks on the LCDindicates data istransmitting.3.If the data is successfullytransmitted, the Bluetooth symbol doesn’t blink any more, and then it will turn off within 5 seconds.If the data transmission fails,it will turn off within 3 minutes.Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPCAUTION 1. 2.  Interference may occur in the vicinity of equipment marked with the following symbol      . And TMB-1490-BS may interfering vicinity electrical equipment.Sensitive people, including pregnant women pre-eclamptic and those who implanted medical electronic instruments, should avoid using the unit whenever possible.Keep the monitor at least 20 centimeters away from the human body (especially the head) when the data transmission is proceeding after measurement.To enable the data transmission function, this product should be paired to Bluetooth end at 2.4 GHz.How to mitigate  possible interference?The range between the device and BT end should be reasonably close, from 1 meter to 10 meters. Please ensure no obstacles between the device and BT end so as to obtain quality connection and to lower the RF output range.To avoid interference, other electronic devices (particularly those with wireless transmission / Transmitter) should be kept at least 1 meter away from the monitor.
Pul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPPul/minMEMORYTIME /DATESMSTARTSTOPDATA MANAGEMENTIf you did not get the correct measurement, you can delete all  results for the selected user by following steps below.Delete the Records1.Hold pressing “SET”  for 3 seconds when themonitor is in the memory recall mode ,the flash display “dEL ALL” will show.2.Press “SET” to confirm deleting and the monitor will turn off.3.If you don’t want to delete the records, press “START/STOP” to escape.4. If there is no record,press “MEM” button,the right display willshow. STARTSTOPINFORMATION FOR USERTips for MeasurementWithin 1 hour after dinner or drinkingWithin 20 minutes after taking a bathIn a very cold environmentImmediate measurement after tea, coffee, smoking When talking or moving your fingersWhen you want to discharge urineMeasurements may be inaccurate if taken in the following circumstances.
INFORMATION FOR USERMaintenanceIn order to get the best performance, please follow the  instructions below.Put in a dry place and avoid the sunshineAvoid intense shakingand collisionsUsing wet cloths to remove dirtAvoid touching water,clean it with a dry cloth in case.Avoid dusty and unstabletemperature environmentDo not attempt to clean the reusable cuff with water and never immerse  the cuff in water.ABOUT BLOOD PRESSUREWhat are systolic pressure and diastolic pressure? pressartery veinblood dischargingSystolicrelaxblood enteringDiastolic  When ventricles contract and pump blood out of the heart, the blood pressure reaches its maximum value in the cycle, which is called systolic pressure. When the ventricles relax, the blood pressure reaches its minimum value in the cycle, which is called diastolic pressure.Irregular Heartbeat DetectorCAUTIONThe appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular heart-beat was detected during measurement. Usually this is NOT a cause for concern. However, if the symbol appears often, we recommend you seek medical advice. Please note that the device does not replace a cardiac examination, but serves to detect pulse irregularities at an early stage.An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is measuringthe systolic and diastolic blood pressure.During each measurement, the monitor records all thepulse intervals and calculate the average ; if there are two or more pulse intervals ,the differencebetween each interval and the average is more than the average value of ±25% , or there are fouror more pulse intervals ,the difference between each interval and the average is more than theaverage value of ±15%,the irregular heartbeat symbol appears on the display when themeasurement results are appear.What is the standard blood pressure classification?The chart on the right is the standard blood pressure classifi-cation published by AmericanHeart Association (AHA).Please consult a physician if your measuring result falls outside the range. Please note that only a physician can tell whether your blood pressure value has reached a dangerous point.CAUTIONBlood Pressure CategoryNormalElevatedHigh Blood Pressure(Hypertension) Stage 1High Blood Pressure(Hypertension) Stage 2Hypertensive Crisis(Consult your doctor immediately)SystolicmmHg (upper#)DiastolicmmHg (lower#)less than 120120-129130-139140 or higherHigher than 180andororand/orless than 8080-8990 or higherHigher than 120This chart reflects blood pressure categories defined by American Heart Association.and less than 80
ABOUT BLOOD PRESSUREWhy does my blood pressure fluctuate throughout theday?Is the result the same if measuring on the right arm?Why do I get a different blood pressure at home compared to the hospital?1. Individual blood pressure varies multiple times everyday. It is also affected by the way you tie your cuff and your measurement position, so please take the measurement under the same conditions.2.If the person takes medicine, the pressure will vary more.3.Wait at least 3 minutes for another measurement.The blood pressure is different even throughout the day due to weather, emotion, exercise etc, Also, there is the “white coat” effect, which means blood pressure usually increases in clinical settings.It is ok for both arms, but there will be some different results for different people. We suggest you measure the same arm every time.What you need to pay attention to when you measure your blood pressure at home: If the cuff is tied properly. If the cuff is too tight or too loose.If the cuff is tied on the upper arm.If you feel anxious.Taking 2-3 deep breaths before beginning will be better for measuring.        Advice: Relax yourself for 4-5 minutes until you calm down.TROUBLESHOOTING    This section includes a list of error messages and frequently asked questions for problems you may encounter with your blood  pressure monitor. If the products not operating as you think it should, check here before arranging for servicing.PROBLEM SYMPTOM CHECK THIS REMEDYNo powerLowbatteriesErrormessageDisplay will not light up.Batteries are exhausted. Replace with new batteriesInsert the batteries correctlyReplace with new batteriesBatteries are insertedincorrectly.Display is dim or show Batteries are low.E 01 showsE 03 showsE 04 showsEExx,shows on the display.A calibration erroroccurred. (XX canbe some digital symbol,such as 01, 02,etc., if this similar situation appear, all belong to calibration error.)Retake the measurement.If the problem persists,contact the retailer or ourcustomer service department for further assistance.Refer to the warranty for contact information and return instructions.The treatment of themeasurement failed.AC adaptor is insertedincorrectly.Insert the AC adaptor tightlyE 02 showsThe cuff is too tight or too loose.Refasten the cuff and thenmeasure again.The monitor detected motion while measuring.Movement can affect themeasurement.Relax for a moment and then measure again.Relax for a moment andthen measure again.The measurement process does not detect the pulse signal.Loosen the clothing onthe arm and then measure again. WarningmessageRelax for a moment.Refasten the cuff and thenmeasure again. If theproblem persists, contactyour physician.“out ” shows Out of measurementrange
Contact InformationFor more information about our products, please visit www.transtek.cn.you can get customer service, usual problems and customer download, transtek will serve you anytime.Manufactured by:Company:Address:Authorized Component1please use the TRANSTEK authorized adapter. AUTHORIZED COMPONENTGuangdong Transtek Medical Electronics Co., Ltd.Zone B, No.105 ,Dongli Road, Torch Development District, Zhongshan,528437,Guangdong,China  Guangdong Transtek Medical Electronics Co., Ltd.AdapterModel:BLJ06L060100P-UInput:AC 100-240V50/60Hz  0.2A MaxOutput:6V      1000mASPECIFICATIONS6VDC 4×AAA batteriesApprox.250g(Excluding the batteries and cuff)A01Digital LCD   V.A.60mm × 92mmApprox.140mm×130mm×49.7mm4×AAA batteries,user manual,AC adapter  6V      1ABattery powered mode: AC adaptor powered mode:(Please only use the recommended  AC adaptor model). About 22cm~32cm or 22cm~42cmType BF applied partWARNING: No modification of this equipment is allowed.Power supplyDisplay modeMeasurement mode Oscillographic testing modeMeasurement rangeMeasurement perimeterof the upper armWeightExternal dimensionsAttachmentMode of operation Continuous operationDegree of protectionProtection against ingress of waterAccuracyNormal working conditionStorage & transportationconditionSoftware VersionPressure:5℃-40℃within±3mmHg(0.4kPa) Pulse value:±5%Rated cuff pressure: 0mmHg~299mmHg(0kPa ~ 39.9kPa)Measurement pressure: SYS: 60mmHg~230mmHg (8.0kPa~30.7kPa) DIA: 40mmHg~130mmHg (5.3kPa~17.3kPa)Pulse value: (40-199)beat/minuteIP21 It means the device could protected against solid foreign objects of 12.5mm and greater, and protect against vertically falling water drops.Device ClassificationBattery Powered Mode: Internally Powered ME EquipmentAC Adaptor Powered Mode: Class II ME EquipmentA temperature range of :+5°C to +40°C A relative humidity range of 15% to 90%, non-condensing, but not requiring a water vapour partial pressure greater than 50 hPaAn atmospheric pressure range of : 700 hPa to 1060 hPaTemperature:-20°C to +60°C$UHODWLYHKXPLGLW\UDQJHRIQRQFRQGHQVLQJat a water vapour pressure up to 50hPa
 COMPLIED STANDARDS LISTComplied Standards ListEN ISO 14971:2012 / ISO 14971:2007 Medical devices - Application of risk management to medical devicesEN 1041:2008 Information supplied by the manufacturer of medical devicesEN 60601-1:2006/ IEC 60601-1:2005+A1:2012 Medical electrical equipment - Part 1: General requirements for basic safety and essential performanceEN 60601-1-11:2015/ IEC 60601-1-11:2015 Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environmentEN 60601-1-2:2015/ IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic disturbances - Requirements and testsEN ISO 81060-1:2012 Non-invasive sphygmomanometers - Part 1: Requirements and test methods for non-automated measurement typeEN 1060-3:1997+A2:2009 Non-invasive sphygmomanometers - Part 3: Supplementary requirements for electro-mechanical blood pressure measuring systemsEN 1060-4:2004 Non-invasive sphygmomanometers - Part 4: Test procedures to determine the overall system accuracy of automated non-invasive sphygmomanometersEN 60601-1-6:2010/IEC 60601-1-6:2010+A1:2013 Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: UsabilityEN 62366-1:2015/ IEC 62366-1:2015 Medical devices - Part 1: Application of usability engineering to medical devicesEN 62304:2006/AC: 2008 / IEC 62304:2006   Medical device software - Software life-cycle processesRisk managementLabelingUser manualGeneral Requirements for SafetyElectromagneticcompatibilityPerformancerequirementsClinical investigationUsabilitySoftware life-cycle processesBio-compatibilityISO 10993-1:2009 Biological evaluation of medical devices- Part 1: Evaluation and testing within a risk management processISO 10993-5:2009 Biological evaluation of medical devices - Part 5: Tests for in vitro cytotoxicityISO 10993-10:2010 Biological evaluation of medical devices - Part 10: Tests for irritation and skin sensitizationEN ISO 15223-1:2016 / ISO 15223-1:2016  Medical devices. Symbols to be used with medical device labels, labelling and information to be supplied. Part 1 : General requirementsIEC 80601-2-30:2013 Medical electrical equipment- Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometersISO 81060-2:2013  Non-invasive sphygmomanometers - Part 2: Clinical validation of automated measurement typeThis device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation.Caution: The user is cautioned that changes or modifications notexpressly approved by the party responsible for compliance could voidthe user's authority to operate the equipment.NOTE: This equipment has been tested and found to comply with thelimits for a Class B digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection againstharmful interference in a residential installation. This equipment generates,uses and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference willnot occur in a particular installation.If this equipment does cause harmful interference to radio or televisionreception, which can be determined by turning the equipment off and on,the user is encouraged to try to correct the interference by one or moreof the following measures:-- Reorient or relocate the receiving antenna.-- Increase the separation between the equipment and receiver.-- Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.-- Consult the dealer or an experienced radio/TV technician for help.FCC Radiation Exposure Statement:This equipment complies with FCC radiation exposure limits set forth foran uncontrolled environment.This transmitter must not be co-located or operating in conjunction withany other antenna or transmitter.FCC StatementFCC ID:OU9TMB1490BSFCC STATEMENT
 EMC GUIDANCE EMC GUIDANCEEMC Guidance1)This product needs special precautions regarding EMC and needs to be installed and put into service according to the EMC information provided,and this unit can be affected by portable and mobile RF communications equipment.2)* Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.3)Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation!4)* Caution: This machine should not be used adjacent to or stacked with other equipment and that if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used.Table 1 Guidance and manufacturer’s declaration – electromagnetic emissionsRF emissions CISPR 11 Group 1 Class B Class ACompliesComplianceHarmonic emissions IEC 61000-3-2Voltage fluctuations/ flicker emissions  IEC 61000-3-3  RF emissions CISPR 11Emissions test Electromagnetic environment - guidanceThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.The device uses RF energy only for its internal function. Therefore, its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment.The device is suitable for use in all establishments,other than domestic and those directly connected to the public low-voltage power supply network that supplies buildings used for domestic purposes. Guidance and manufacturer’s declaration – electromagnetic immunity Immunity test ±8 kV contact±15 kV air  ±8 kV contact±15 kV air  ±2 kV power supply lines: line(s) to line(s): ±1 kV  line(s) to earth: ±2 kV 0%UT; 0.5 cycleAt 0°, 45°, 90°, 135°,180°,225°,270° and 315°0%UT ;  1 cycle and 70%UT ; 25/30 cyclesSingle phase: at 0°0% UT ; 300 cycle30 A/m50Hz/60HzNOTE      UT is the a.c. mains voltage prior to application of the test level. Table 2 Compliance levelElectrostatic discharge (ESD) IEC 61000-4-2 Electromagnetic environment - guidance30 A/m50Hz/60HzPower frequency (50Hz/60Hz) magnetic field IEC 61000-4-8 Voltage dips, short interruptionsand voltagevariations on power supply input linesIEC 61000-4-11 Electrical fast transient/burst IEC 61000-4-4 SurgeIEC61000-4-5input/output lines:±1 kVThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.IEC 60601 test levelFloors should be wood, concrete or ceramic tile. If floors are covered with synthetic material, the relative humidity should be at least 30%.±2 kV power supply lines: 100 kHz repetitionfrequencyline(s) to line(s): ±1 kV  100 kHz repetitionfrequencyMains power quality should be that of a typical commercial or hospital environment.Mains power quality should be that of a typical commercial or hospital environment.Mains power quality should be that of a typical commercial or hospital environment.Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.0% UT ; 0.5 cycleAt 0°, 45°, 90°, 135°,180°,225°,270° and 315°0% UT ;  1 cycle and 70% UT ; 25/30 cyclesSingle phase: at 0°0% UT ;300 cycle
 EMC GUIDANCETable 3Guidance and manufacturer’s declaration – electromagnetic immunityImmunity test Compliance levelIEC 60601 Test levelConducted RFIEC 61000-4-6 Radiated RF IEC 61000-4-310V/m, 80% Amat 1kHz150 kHz to80 MHz: 3 Vrms6Vrms (in ISM and amateur radio bands)80% Am at 1kHz Electromagnetic environment - guidanceNOTE 1  At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2  These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.aField strengths from fixed transmitters, such as base stations for radio (cellular / cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the device.Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3V/m.bThe device is intended for use in the electromagnetic environment specified below. The customer or the user of the device should assure that it is used in such an environment.150 kHz to80 MHz: 3 Vrms6Vrms (in ISM and amateur radio bands)80% Am at 1kHz Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation appropriate for the frequency of the transmitter.Recommended separation distances:d=0.35        ;d=1.210V/m, 80% Amat 1kHz80 MHz to 800 MHz:d=1.2800 MHz to 2.7 GHz:d=2.3where, P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer, d is the recommended separation distance in meters (m).  Field strengths from fixed RF transmitters, as determined by an electromagnetic site survey, should be less than the compliance level in each frequency range.Interference may occur in the vicinity of equipment marked with the followingsymbol:PPPP 150 kHz to 80 MHz  80 MHz to 800 MHz  800 MHz to 2.7 GHz Table 4Recommended separation distances between portable and mobile RF communications equipment and the device.Rated maximum outputpower of transmitter(W) Separation distance according to frequency of transmitter (m)0.010.11101000.12 0.120.381.23.8120.230.732.37.323=d =d 1.2 2.3=d0.371.23.8123.5The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmittters) and the device as recommended below, according to the maximum output power of the communications equipment.For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.NOTE 1    At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.NOTE 2    These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.PPPEMC GUIDANCE
EMC GUIDANCE Table 5Guidance and manufacturer’s declaration - electromagnetic immunityTest Frequency (MHz)385 0.3 27The device is intended for use in the electromagnetic environment specified below. The customer or the user of the device, should assure that it is used in such an environment.NOTE If necessary to achieve the IMMUNITY TEST LEVEL, the distance between the transmitting antenna and the ME EQUIPMENT or ME SYSTEM may be reduced to 1 m. The 1 m test distance is permitted by IEC 61000-4-3.Radiated RF IEC61000-4-3 (Test specifications for ENCLOSURE PORT IMMUNITY to RF wireless communications equipment) Band a)(MHz)Service a) Modulation b) Modulation b)(W)Distance (m)IMMUNITY TEST LEVEL (V/m)380-390 TETRA 400Pulse modulation b) 18Hz1.8450 380-390GMRS 460,FRS 460FM c) ± 5kHzdeviation 1kHzsine2 0.3 28710 704-787745780LTE Band13,17Pulse modulation b)217Hz0.2 0.3 9810870930800-960GSM 800/900,TETRA 800,iDEN 820,CDMA 850,LTE Band 5Pulse modulation b)18Hz20.3 281720184519701700-1990GSM 1800;CDMA 1900;GSM 1900;DECT;LTE Band 1,3,4,25; UMTSPulse modulation b)217Hz20.3 2820.3 282450 2400-2570Bluetooth,WLAN,802.11 b/g/n, RFID2450, LTEBand 7Pulse modulation b)217 Hz5240524057855100-5800WLAN802.11a/nPulsemodulation b)217 Hz0.2 0.3 9a) For some services, only the uplink frequencies are included.b) The carrier shall be modulated using a 50% duty cycle square wave signal.c) As an alternative to FM modulation, 50% pulse modulation at 18 Hz may be used because while it does not represent actual modulation, it would be worst case.The MANUFACTURER should consider reducing the minimum separation distance, based on RISK MANAGEMENT, and using higher IMMUNITY TEST LEVELS that are appropriate for the reduced minimum separation distance. Minimum separation distances for higher IMMUNITY TEST LEVELS shall be calculated using the following equation:                                                                E=Where P is the maximum power in W, d is the minimum separation distance in m, and E is the IMMUNITY TEST LEVEL in V/m.