Trilliant Networks G30I210 Utility Meter User Manual Manual

Trilliant Networks Utility Meter Manual

Manual

Download: Trilliant Networks G30I210 Utility Meter User Manual Manual
Mirror Download [FCC.gov]Trilliant Networks G30I210 Utility Meter User Manual Manual
Document ID1435651
Application IDJEYQsDCNtWzULadO879BmQ==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize79.42kB (992718 bits)
Date Submitted2011-03-22 00:00:00
Date Available2011-03-22 00:00:00
Creation Date2011-03-10 15:41:55
Producing SoftwareAcrobat Distiller 8.1.0 (Windows)
Document Lastmod2011-03-10 15:41:55
Document TitleMicrosoft Word - pa-0115a-1.4-RES-3000-I210+_Meter retrofit.doc
Document CreatorPScript5.dll Version 5.2.2
Document Author: nwhitehead

RES-3000-I210+ / I210+RD / I210+c
SecureMesh retrofit for GE I-210+ / I-210+RD / I-210+c / I-210+cRD meters
Introduction
This document will help the SecureMesh user to retrofit the product model RES-3000-I210+,
RES-3000-I210+RD & RES-3000-I210+c in a GE I-210+, GE I-210+RD, GE I-210+c & GE
I-210+cRD meter as intended.
Safety and Assembly Cautions
- Warning: The meter carries lethal voltages. The meter must be completely disconnected
from any external circuits. Failure to observe this practice can result in serious injury or
death.
- Caution: These devices are electrostatic sensitive. It is best to use a grounded electrostatic
mat and wrist strap to prevent electrostatic discharge.
- Important: It is not necessary to completely separate the top of the meter from the base of
the meter for this retrofit procedure. However, if the two parts are completely disconnected
and separated, it is extremely important to keep each meter component together for reassembly. This is due to the top section of the meter containing calibration “characterization”
programming for the CTs in the meter base. If these components get mixed up with other
meter components, current measurement errors will occur.
SecureMesh Radio Specifications:
•
•
•
•
•
•
•
•
•
IEEE Standard :
Power Output :
Radio Sensitivity :
RF Data rate :
Operating Frequency :
Network Topology :
Modulation :
Physical Dimensions :
Antenna :
PA-0115A Rev. 1.4
IEEE 802.15.4
+30 dBm
-99 dBm
250 kbps
2.400-2.483 GHz
Mesh
O-QPSK
2.54” x 3.47”
Dipole, 3.5 dBi
March 11th, 2011
Page 1 of 6
RES-3000-I210+ / I210+RD / I210+c
Industry Canada Compliance Statement (English & French)
This device complies with industry Canada license-exempt RSS standard(s). Operation is subject to the
following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired
operation of the device.
"Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a
type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce
potential radio interference to other users, the antenna type and its gain should be so chosen that
the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication."
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio exempts
de licence. L’exploitation est autorisée aux deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage.
2. L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d’en compromettre le fonctionnement.
"Selon les règles d’Industrie Canada, cet appareil transmetteur radio peut seulement être en opération
avec l’utilisation d’une antenne de type et d’un gain maximum (ou moindre) approuvée pour le
transmetteur par Industrie Canada. Pour réduire l’interférence potentielle de la radio versus les autres
utilisateurs, le type d’antenne et son gain devrait être choisis de façon à ce que la puissance isotrope
irradiée équivalente (e.i.r.p.) ne soit pas supérieure à ce qui est requis pour avoir une bonne
communication. "
Federal Communication Commission Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause
undesired operation.
PA-0115A Rev. 1.4
March 11th, 2011
Page 2 of 6
RES-3000-I210+ / I210+RD / I210+c
FCC Warning
Changes or modifications not expressly approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct the interference by one of the
following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
To comply with FCC and Industry Canada RF exposure limits for general population /
uncontrolled exposure, the antenna(s) used for this transmitter must be installed to
provide a separation distance of at least 20 cm from all persons and must not be colocated or operating in conjunction with any other antenna or transmitter.
Material
• GE I-210+ or GE I-210+RD or GE I-210+c or GE
I-210+cRD meters (must be AMR configured)
• Trilliant SecureMesh RES-3000-I210+ or RES3000-I210+RD or RES-3000-I210+c.
• Mounting Screws (HS-0013I) – QTY = 2
PA-0115A Rev. 1.4
March 11th, 2011
Page 3 of 6
RES-3000-I210+ / I210+RD / I210+c
Procedure
Note: In this procedure, the “I-210+” wording will be used for all 4 meter designations: I-210+,
I-210+RD, I-210+c & the I-210+cRD meters.
The following table represents the Trilliant SecureMesh product associated to the GE meter:
•
RES-3000-I-210+ product must be installed into an I-210+ meter
•
RES-3000-I-210+RD product must be installed into an I-210+RD meter.
•
RES-3000-I-210+c product can be installed into an I-210+c or I-210+cRD meter.
1. If it is not already done, dis-assemble the
I-210+ meter clear cover to access the 2 post
receptacle holes in the nameplate carrier and
the I-210+ board connector as shown.
Post
receptacles
Board
connector
2. With the SecureMesh board in this orientation, please ensure that the antenna board is
securely held in this position and that the 2 HEX posts are properly screwed.
HEX Post
HEX Post
PA-0115A Rev. 1.4
March 11th, 2011
Page 4 of 6
RES-3000-I210+ / I210+RD / I210+c
3. Install the SecureMesh board by first inserting the female connector in the I-210+ male
connector as shown. Align the 2 HEX Aluminum posts with the 2 holes in the GE I210+
meter faceplate.
Male-Female
connector mating
4. Attach the two mounting screws (HS-0013I)
through the faceplate into the 2 HEX posts so
that the SecureMesh board is held securely in
place. Torque screws to 2 +/-0.2 Inch pounds.
Screws
(For Trilliant internal use: Milwaukee #2)
PA-0115A Rev. 1.4
March 11th, 2011
Page 5 of 6
RES-3000-I210+ / I210+RD / I210+c
5. Affix any missing label on the meter faceplate,
finalize inspection & test as required
Note: if this label is supplied by Trilliant, use HI0274A for the I-210+ or HI-0275A for the I-210+RD
or HI-0345A for the I-210+c.
6. Reassemble the I-210+ clear cover on its base.
7. Perform functional test & configuration as required.
PA-0115A Rev. 1.4
March 11th, 2011
Page 6 of 6

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Producer                        : Acrobat Distiller 8.1.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Modify Date                     : 2011:03:10 15:41:55-05:00
Create Date                     : 2011:03:10 15:41:55-05:00
Format                          : application/pdf
Title                           : Microsoft Word - pa-0115a-1.4-RES-3000-I210+_Meter retrofit.doc
Creator                         : nwhitehead
Document ID                     : uuid:4e36d8d6-92ca-4c4e-8823-7bea2dd0acde
Instance ID                     : uuid:ce8548a2-3b5e-43fa-a044-01757a8f54db
Page Count                      : 6
Author                          : nwhitehead
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TMB-G30I210

Navigation menu