2 Parklawn Drive Suite F Bethel Connecticut 06801 018-4 WIRELESS TRANSMITTER INSTRUCTION SHEET AND TROUBLESHOOTING GUIDE 018-4 Two Button Transmitter • 500 Foot Range • LED indicates operation • 2 Channel Remote Control • Rolling Code • CR2032 Battery Included • FCC, IC Approved CAUTION: CHANGES OR MODIFICATIONS TO THE 017TDC-4 AND 018-4 NOT EXPRESSLY APPROVED BY THE PARTY RESPONSIBLE FOR COMPLIANCE COULD VOID THE USERS AUTHORITY TO OPERATE THE DEVICE. NOTE: BOTH PUSH BUTTONS ON THE 018-4 WILL TRIGGER THE 017TDC-4 018-4 REMOTE HOW TO PAIR REMOTE TO CONTROLLER: You need to pair the 018-4 remote to the 017TDC-4 receiver/controller for your system to work. The 017TDC-4 receiver can work with up to eight (8) transmitters. To pair the remote with the reciever/controller follow the steps below: 1. Press the PRG button on the 017TDC-4 (see picture below for the location of the PRG switch) the LED light next to the PRG button will turn ON indicating that it is ready to pair. 2. Push any of the two 018-4 buttons to start pairing and the 017TDC-4 LED will blink to indicate that the pairing is successful. 3. For additional remotes, do the same procedure 1 & 2 above using the new remotes you want to pair. The 017TDC-4 will remember the previous remotes paired up to a maximum of 8 remotes. WHAT THE RELAY TERMINALS LEGEND MEAN COMM NC NO BUTTON 2 BUTTON 1 NO - NORMALLY OPEN TERMINAL COMM - COMMON TERMINAL NC - NORMALLY CLOSED TERMINAL BUTTON LED INDICATOR BUTTON 1 RELAY TERMINAS 018-4 REMOTE NO COMM NC 017TDC-4 CONTROLLER BUTTON 2 RELAY TERMINAS NO COMM NC + POWER TERMINAL - POWER TERMINAL PRG BUTTON LED INDICATOR MODE SELECTOR SWITCH MODE SELECTOR SWITCH BUTTON 1 The mode selector switch settings determines the time the relay is ON and the action of how the relay will switch. The mode selector, switches 1 and 2 works with button #1 of the remote and switches 3 and 4 works with button #2. BUTTON 2 Relay will stay ON for 4 seconds at this setting. BUTTON 1 4 SEC “ON” BUTTON 1 8 SEC “ON” Relay will stay ON for 8 seconds at this setting. BUTTON 1 16 SEC “ON” Relay will stay ON for 16 seconds at this setting. BUTTON 1 PUSH “ON” PUSH “OFF” Relay will turn ON when the button is pressed and turn OFF when the button is pressed again. BATTERY SPECIFICATION AND ORIENTATION: POSITIVE SIDE USE CR2032 LITHIUM COIN BATTERY TROUBLESHOOTING GUIDE SECTION: The 017TDC-4 and the 018-4 operates on radio frequency (RF) signaling and may have some problems being installed in certain locations. Radio frequency (RF) signals are similar in principle as two people conversing. RF communications however are more difficult to troubleshoot because RF modulates at frequencies that are not audible to human ears. Let's say that you and I are comfortably conversing, if a person starts talking loud next to us, then we may start to go closer and closer to each other until we can once again understand each other. RF devices will work the same way. The first objective in troubleshooting is to spot the troublemaker, in this case, the offending device. The offending device can be one or the combination of the following items: light dimmers, fluorescent lights, TV or computer CRT displays and any piece of equipment using a switching power supply or "clock" oscillator (computers and other digital devices). Additionally, ham and CB transmitters, remote controls, wireless phones, cellular phones, commercial taxi/police/aircraft radios, microwave ovens, motion sensors, radar systems, and a myriad of medical and industrial RF devices. As you can appreciate from the litany of devices above almost any perimeter can have multiple sources of RF noisemakers. Deciding the final position for mounting the 017TDC will immensely improve your chances of installation success. Before screwing the 017TDC receiver down, choose an initial location and use a 10 feet electrical cord and walk test the 017TDC's sensitivity to PROBLEM POSSIBLE CAUSE SOLUTION Transmitter does not work (LED lamp does not light) Battery is low Replace the battery. Use an CR2032 size 3VDC Lithium battery. Battery is not properly installed Reinstall the battery correctly (see battery polarity drawing above) Transmitter does not work (LED lamp turns ON) Transmitter is out of range Move the transmitter closer to the receiver (see above article) Wiring connections may be faulty Check your wiring scheme refer to the 017TDC-4 instruction sheet. Remote & Controller are improperly paired Pair the remote and controller again see instructions on the front page. Wiring connection may be faulty Check your wiring scheme refer to the 017TDC-4 instruction sheet. RF interference Read the article above regarding RF interference Faulty power supply Check the power supply for correctness of voltage and capacity Loose wiring connections or shorted wire Carefully check all your wiring connections and tighten loose connections Receiver works intermittently For additional information regarding the 017TDC-4 Wireless Controller and to download this document in electronic form (Adobe Acrobat PDF). Go to our website at http://www.trineonline.com/interior/support/instruction_sheet.html NOTICE REGARDING THE 018-4 TRANSMITTER FCC ID: PFO018-4 018-4 TRANSMITTER This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference and (2) this device must accept any interference received, including interference that may cause undesired operation. TRINE ACCESS TECHNOLOGY 2 Parklawn Drive, Suite F l Bethel l Connecticut l 06801 Website: www.TrineOnline.com Tel. No. (203) 730-1756 l Fax No. (203) 730-1781 018-4 INSTRUCTION SHEET, REV. A 12/2016
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : fred Create Date : 2016:12:12 10:57:41-05:00 Modify Date : 2016:12:12 11:44:15-05:00 XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2016:12:12 11:44:15-05:00 Producer : Acrobat Distiller 9.5.5 (Windows) Format : application/pdf Title : 018-4 Instruction Sheet p1-2.ai Creator : fred Document ID : uuid:32190c6b-c93c-47a6-a485-eea9b3076ad3 Instance ID : uuid:2a430278-5c8c-41c0-b1b1-3fdfb24d4ce8 Page Count : 2EXIF Metadata provided by EXIF.tools