Tripp Lite
1111 West 35th Street
Chicago, IL 60609 USA
Telephone: +(773) 869 1234
E-mail: saleshelp@tripplite.com

Model Number: SMX5000XLRT3U
SmartPro 5kVA Line Interactive Sine Wave UPS, Extended-run & SNMPWEBCARD options, 3U Rack/Tower,
USB, Serial, EPO, 230V
Highlights
5kVA / 5000VA line interactive 3U rack/tower UPS; Sine wave output
230V nominal output during brownouts to 170V and overvoltages to 282V
USB, Serial, EPO & optional SNMP/Web card monitoring options
3U all-in-one chassis; 98% efficiency
Hardwire input; 8 C13 & 3 C19 outlets

Description
5000VA line interactive UPS system for server, network and telecommunications equipment. 5kVA UPS with internal batteries installs in only 3 rack
spaces with a depth of only 635mm / 25 inches. High 98% line-power efficiency rating reduces energy consumption and BTU heat output.
Expandable battery runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack compatible)
external battery packs. Uninterruptible Power Supply (UPS) switches to battery-derived AC output during power failures and extreme voltage
variations. Line interactive Automatic Voltage Regulation (AVR) offers voltage boost during brownouts and voltage reduction during overvoltage
conditions to maintain regulated 230v output over an input range of 170-282V. Supports hardwire input. Includes C19 and C13 output receptacles.
Network-grade AC surge and noise suppression. Network management interfaces support communications via USB, DB9 serial and
SNMPWEBCARD slot. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3
network interfaces at once. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. 3-stage metered
current monitoring and battery charge status LEDs. Utility power and voltage regulation LEDs. Audible alarm. Self-test. 4-post rackmount installation
accessories included; 2-9USTAND tower kit and 2POSTRMKITWM two post rack mounting accessories available. Field-replaceable, hot-swappable
internal batteries and external battery packs.

Package Includes
SMX5000XLRT3U UPS system
PowerAlert Software and Cabling
Mounting hardware for 4 post rackmount installation
Warranty information
Instruction manual

Features
5000VA/3750 watt max. output power capacity compatible with International 230V input voltage
3U rack/tower UPS installs in standard 19 inch rack enclosures with an installed depth of only 635mm / 25in
Protects sensitive networking equipment from blackouts, voltage fluctuations and transient surges
Line Interactive Automatic Voltage Regulation (AVR) corrects 230V nominal input from 170 to 282VAC to usable 230V levels without
consuming battery power
AVR circuits boost undervoltages from 170 to 199V by 12% and reduce overvoltages from 245 to 282V by 12%
Network interfaces support simultaneous communications via USB, DB9 serial or contact closure and SNMPWEBCARD slot
Included PowerAlert UPS monitoring software supports safe unattended shutdown, monitoring and control via local connected servers, plus
any number of additional servers over IP
Communications ports support on-battery, low-battery, power-restored, AC-voltage, DC-voltage, output current monitoring, battery charge
current, battery capacity, internal UPS temperature, AC line frequency, timed inverter shutoff and activate self-test
Built-in Emergency Power Off (EPO) interface with cable
Sine wave output in AC and battery mode

Expandable runtime with optional BP48V24-2U (limit 1), BP48V60RT-3U (multi-pack compatible) and BP48V27-2US (multi-pack
compatible) external battery packs
Half/full load runtime of 27/10 minutes with internal batteries
Includes 11 output receptacles (3 C19/8 C13)
Hardwire input AC connection
3 stage metered LEDs offer current monitoring and battery charge level
Mains power and voltage regulation LEDs offer at-a-glance power status information
Front panel switches support self-test and alarm cancel functions
Included adjustable mounting rails support installation in 4 post 19 inch racks
Supports 2 post rackmount installation with optional 2POSTRMKIT accessory
Supports upright tower placement with optional 2-9USTAND accessory
CE, GOST, SASO listed

Specifications
OUTPUT
Output Volt Amp Capacity
(VA)

5000

Output kVA capacity (kVA)

5

Output Watt Capacity
(watts)

3750

Output kW capacity

3.75

Output power factor

0.75

Nominal Output Voltage(s)
Supported

220V; 230V; 240V

Nominal Voltage details

230v nominal inverter output voltage

Frequency compatibility

50 / 60 Hz

Output voltage regulation
(line mode)

-17%, +8%

Output voltage regulation
(Battery mode)

+/- 5%

Built-in UPS output
receptacles

8 C13 outlet(s); 3 C19 outlet(s)

Included output power
cables

Includes 3 C13 to C14 output power cables

Output circuit breaker

15A (x3) breaker supports 1 C19 outlet each, 10A (x2) breaker supports 4 C13 outlets each

Output AC waveform (AC
mode)

Sine wave

Output AC waveform
(battery mode)

Pure Sine wave

INPUT
Rated input current (at
maximum load)

27A

Nominal Input Voltage(s)
Supported

230V AC

UPS input connection type

Hardwire

Phase

Single-Phase

BATTERY
Full load runtime (minutes)

8.5 min. (3750w)

Half load runtime (minutes)

20 min. (1875w)

Expandable battery runtime

Extended runtime supported via optional external battery packs

External battery pack
compatibility

BP48V24-2U (limit 1); BP48V60RT-3U (multi-pack compatible); BP48V27-2US (multi-pack compatible)

DC system voltage (VDC)

48

Battery recharge rate
(included batteries)

Less than 4 hours from 10% to 90%

Replacement battery
cartridge (internal UPS
battery replacement)

RBC94-3U (quantity 3)

Battery Access

Front panel battery access door

Battery replacement
description

Hot-swappable, user replaceable batteries

VOLTAGE REGULATION
Voltage regulation
description

Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 170 to 282

Overvoltage correction

Input voltages between 245 and 282 are reduced by 12%

Undervoltage correction

Input voltages between 170 and 199 are boosted by 12%

LEDS ALARMS & SWITCHES
LED Indicators

5 LEDs indicate line power, battery power, overload, voltage regulation and battery low/replace status

Alarms

Audible alarm indicates power-failure, overload and low-battery conditions

Alarm cancel operation

Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate
low-battery status

Switches

2 Switches control off/on power status and alarm-cancel/self-test operation

SURGE / NOISE SUPPRESSION
UPS AC suppression joule
rating

480

UPS AC suppression
response time

Instantaneous

EMI / RFI AC noise
suppression

Yes

PHYSICAL
Installation form factors
supported with optional
accessories

2 post rackmount (2POSTRMKITWM); Tower (2-9USTAND)

Primary form factor

Rackmount

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / inches)

5.2 x 17.5 x 25

UPS / Power Module
dimensions in primary form
factor (height x width x
depth / cm)

13.3 x 44.4 x 63.5

Rack Height

3U

Secondary form factor

Tower (requires 2-9USTAND)

UPS / Power Module weight
(lbs)

143

UPS / Power Module weight
(kg)

64.9

UPS Shipping dimensions
(height x width x depth /
inches)

11.3 x 23 x 31.5

UPS Shipping dimensions
(height x width x depth / cm)

28.6 x 58.4 x 80

Shipping weight (lbs)

182

Shipping weight (kg)

82.6

Cooling method

Fans

UPS housing material

Steel

ENVIRONMENTAL
Operating Temperature
Range

+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius

Storage Temperature Range

+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius

Relative Humidity

0 to 95%, non-condensing

AC mode BTU / hr. (full
load)

271

AC mode efficiency rating
(100% load)

98%

COMMUNICATIONS
Communications interface

USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface

Network monitoring port
description

Supports detailed monitoring of UPS and site power conditions

PowerAlert software

Included

Communications cable

USB and DB9 cabling included

WatchDog compatibility

Supports Watchdog application, OS and hard-reboot restart options for remote applications

LINE / BATTERY TRANSFER
Transfer time

2-4 milliseconds

Low voltage transfer to
battery power (setpoint)

170

High voltage transfer to
battery power (setpoint)

282

SPECIAL FEATURES
Grounding lug

Back panel grounding lug

Cold Start (startup in
battery mode during a
power failure)

Cold-start operation supported

High availability UPS
features

Hot swappable batteries

Green & high efficiency
features

Greater than 95% efficiency - GREEN UPS

CERTIFICATIONS
UPS Certifications

CE

UPS Certification details

Class A (EMI)

WARRANTY
Product Warranty Period
(International)

2-year limited warranty

Product Warranty Period
(Mexico)

2-year limited warranty

Product Warranty Period
(Puerto Rico)

2-year limited warranty

Related Items
Optional Products
Related Model

Description

Qty.

SNMPWEBCARD

For remote monitoring and control via SNMP, Web, or Telnet.

1

ENVIROSENSE

Monitors temperature, humidity and contact-closure inputs. (Requires SNMPWEBCARD
or switched PDU.)

1

SRSWITCH

Magnetic Door Switch Kit for front and rear doors; requires ENVIROSENSE

1

BP48V27-2US

BP48V27-2US - 2U External 48V Rack/Tower Battery pack for select Tripp Lite UPS
Systems

1

BP48V24-2U

BP48V24-2U - 2U External 48V Rack/Tower Battery Pack for select Tripp Lite UPS
Systems

1

BP48V60RT-3U

External Battery Pack and Cable. 3U, Expandable, Blue 2-Point Connector

1

PDU12IEC

Basic PDU / Power Distribution Unit - Safe, reliable power distribution for critical
networking equipment

1

2-9USTAND

Enables Tower Placement of Rackmount UPS Systems

1

MODBUSCARD

For remote monitoring and control via MODBUS protocol

1

2POSTRMKITHD

Enables 2-Post Rackmount Installation of 3U and Larger UPS, Transformer and Battery
Pack Components

1

More information, including related products, owner's manuals, and additional technical specifications, can be found online at
http://www.tripplite.com/sku/SMX5000XLRT3U.

Copyright © 2014 Tripp Lite. All rights reserved. All trademarks are the sole property of their respective owners. Tripp Lite has a policy of continuous
improvement. Specifications are subject to change without notice. Photos may differ slightly from final products.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 5
Producer                        : iText 2.1.0 (by lowagie.com)
Modify Date                     : 2014:03:01 03:38:16-06:00
Create Date                     : 2014:03:01 03:38:16-06:00
EXIF Metadata provided by EXIF.tools