True Manufacturing Company Swing Glass Door Merchandiser Refrigerator Gdm 26 Users Manual Elstat Training Booklet
GDM-26 to the manual 69e7bfc4-9823-42fc-b9c6-362f5d3d8f24
2015-02-03
: True-Manufacturing-Company True-Manufacturing-Company-Swing-Glass-Door-Merchandiser-Refrigerator-Gdm-26-Users-Manual-460497 true-manufacturing-company-swing-glass-door-merchandiser-refrigerator-gdm-26-users-manual-460497 true-manufacturing-company pdf
Open the PDF directly: View PDF .
Page Count: 9
Download | |
Open PDF In Browser | View PDF |
ELSTAT TRAINING BOOKLET GDM SERIES COOLER EQUIPPED WITH EMS (ELSTAT) CONTROL GDM-26 TABLE OF CONTENTS · ELSTAT SEQUENCE OF OPERATION · ELSTAT COMPONENTS · FRONT VIEW OF ELSTAT · REAR VIEW OF CONTROLLER · FREQUENTLY ASKED QUESTIONS (FAQ) · NORMAL OPERATING CODES · FAULT CODES/ TROUBLESHOOTING · TROUBLESHOOTING GUIDE · PARAMETERS 2 ELSTAT SEQUENCE OF OPERATION Once the cabinet is plugged in, the ELSTAT control will flash "888" and then go through a parameter check. Once completed, the control will do a "soft start". Lights come on first, approximately 30 seconds later the compressor will start. Approximately 30 seconds from the compressor start up, the evap motor will start. The control will display "Use". The control will then cycle the compressor on and off at the predetermined temp (Model specific). The whole time the controller is on it is learning the customer traffic. Once enough data has been accumulated the controller will now cycle between two modes. "Standby" and "Use". In the standby mode the controller predicts that customer traffic is nonexistent. It will display (---). It cycles the compressor to hold about 50˚F. It shuts the lights off and cycles the evap fan motor. It will hold this pattern until roughly 2 hours before customer traffic is predicted to start. The controller will then switch into the "use" mode. Cycling the compressor on and off based on temperature (Approx 36˚F to 38˚F product temp). Running lights continuously. The controller will then cycle between these two modes. 3 (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- &-45"5$0.10/&/54 Controller Transformer Probe Evaporator Fan Evaporator Coil Evaporator Fan Evaporator Coil Airflow Airflow Elstat 9 Elstat 1 8 2 3 9 1 8 7 2 4 3 6 7 5 4 6 Probe Location 2 GDM-10 through GDM-37 GDM-45 to GDM-72 Probe is in return air mounted by the evaporator fan motor. Probe is in the discharge air stream Off of the Evaporator Coil 4 &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN 5 Probe Location 1 (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- '30/57*&80'&-45"5 Perishable Mode Light Waterdrops Snowflake Up/Down Key &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN 5 (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- 3&"37*&80'$0/530--&3 /0 1. 2. 3. 4. 5. 6. 7. 8. 9. 6 /".& Line In Lights Not Used Appliance Sensor Compressor Fan (s) 12 Vac Not Used Not Used &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- FREQUENTLY ASKED QUESTIONS $BOUIF&MTUBUDPNFPVUPGUIF4UBOECZNPEFCFGPSFJUTQSFEFUFSNJOFEUJNF /P If the motion sensor is set off during the "Stand by" mode the control will automatically turn the lights on, however it will stay in stand by mode. $BOUIF&MTUBUCFTFUVQGPSDPOUJOVPVTVTFBOEOPUHPJOUPUIF4UBOECZNPEF :FT The control can be set into perishable mode. This would shut down the "stand by" mode. The lights will still cycle (like stand by mode) when cabinet doesn't see activity. /05&5IFSFJTOPBCJMJUZUPTFUMJHIUTPOBMMUIFUJNF $BOMJHIUTCFTFUUPTUBZPOBUBMMUJNFT /P Elstat controller does not have this capability. Lights will always turn off in "stand by" Mode. )PXEP*QVUDPOUSPMMFSJOUP1FSJTIBCMFNPEF t1FSJTIBCMFNPEFJTVTFEXIFOBOZUIJOHQFSJTIBCMFJTCFJOHTUPSFEJOUIFDBCJOFU t*OQFSJTIBCMFNPEF DBCJOFUXJMMNBJOUBJOB¡'¡'QSPEVDUUFNQFSBUVSF5IF cabinet will not go into standby mode. /05&"MM&OFSHZ4UBSDBCJOFUTBSFTIJQQFEJOQFSJTIBCMFNPEF t 1SFTTUIFTFUCVUUPOLFZ MPPLTMJLFBTOPXGMBLF UIFTDSFFOTIPVMETIPX1"4 t:PVXJMMOPXOFFEUPFOUFSUIFLFZEBODF t1SFTTUIFTOPXGMBLFLFZCFFQT t1SFTTUIFVQBSSPXLFZCFFQT t1SFTTUIFEPXOBSSPXLFZCFFQ t1SFTTUIFXBUFSESPQTLFZCFFQT TIPVMETIPXEJTQMBZPG14 t/PXQSFTTBOEIPMEEPXOUIFTOPXGMBLFLFZVOUJMUIFTDSFFOTIPXT1&SBOE t/FYUQSFTTBOEIPMEUIFVQBSSPXLFZVOUJMUIFTDSFFOTIPXT1&SBOE t8BJUVOUJMDPOUSPMMFSSFBET64&VOQMVHUIFDBCJOFUBOEQMVHJUCBDLJO"UUIJT point the red LED in center of the control should be “on” which means that the control is in perishable mode. )PXEP*QFSGPSNB)BMGSFTFU BOEXIBUJTJU Half reset clears any of the learning memory. t1VTIUIFTFUCVUUPOLFZ MPPLTMJLFBTOPXGMBLF UIFTDSFFOTIPVMETIPX1"4 t:PVXJMMOPXOFFEUPFOUFSUIFLFZEBODF t1SFTTUIFTOPXGMBLFLFZCFFQT t1SFTTUIFVQBSSPXLFZCFFQT t1SFTTUIFEPXOBSSPXLFZCFFQ t1SFTTUIFXBUFSESPQTLFZCFFQT TIPVMETIPXEJTQMBZPG14 t1SFTTBOEIPMEUIFEPXOBSSPXLFZVOUJMZPVWJFX)3 t1SFTTUIFTOPXGMBLFLFZ EJTQMBZTIPVMETIPX1"4 t3FFOUFSLFZEBODFBOEUIF)BMG3FTFUJTDPNQMFUF &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN 7 (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- /03."-01&3"5*/($0%&4 Normal operating mode. Cabinet should be holding proper product temperature. Units is in Standby mode. Control will cycle the unit at a warmer temperature. Lights will be off. Units is in defrost . Compressor has been shut off and evaporator fan motor is running to clear any ice that may have accumulated. This is a predetermined program function. '"6-5$0%&45306#-&4)005*/( Freeze up protection. This unit has gone down below the minimum temperature Set Point. Refrigeration System Failure. The unit has not satisfied the set point in the amount of time allowed. 1PTTJCMF1SPCMFNT "DUJPOUPUBLF 1PTTJCMF1SPCMFNT Compressor not shutting off Check compressor. Relay at controller Unit is not cooling Check the Refrigeration System Faulty Probe Ohm out evaporator probe Faulty Probe Ohm out evaporator probe Faulty Controller Parameters have been changed Check parameter list Bypass control to see if system will run Parameters have been changed Check the parameter list Power supply voltage is low. "DUJPOUPUBLF Power supply voltage is too high. 1PTTJCMF1SPCMFNT "DUJPOUPUBLF 1PTTJCMF1SPCMFNT "DUJPOUPUBLF Poor voltage at outlet Verify proper voltage to cabinet High voltage at outlet Verify proper voltage to cabinet Faulty Transformer Verify 120V to transformer. Check for 12V on secondary. Connector 7 (see page 2) Faulty Transformer Verify 120V to transformer. Check for 12V on secondary. Connector 7 (see page 2) Faulty Controller Bypass control to see if system will run Faulty Elstat Faulty Elstat If 12V is present at connector 7, replace Elstat If 12V is present at connector 7, replace Elstat. Probe failure Elstat Probes by the evaporator motor GDM-10 to 33 probes in air stream GDM-35 to 72 8 1PTTJCMF1SPCMFNT "DUJPOUPUBLF 7BMVF 0INT Connector off at controller Verify that connector 4 is in place (see page 2) ¡ 32,000 Ohms ¡ 12,000 Ohms Probe is open Ohm out probe ¡ 9,300 Ohms Probe is shorted Ohm out probe ¡ 8,500 Ohms Probe wire is open Ohm out probe wire ¡ 7,000 Ohms &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN (%.4&3*&4$00-&3&26*11&%8*5)&.4 &-45"5 $0/530- 5306#-&4)005*/((6*%& 5306#-&4)005*/((6*%& (Please note this does not cover any and all situations) $PNQMBJOU $BCJOFUOPUDPMEFOPVHI 1PTTJCMF$BVTF 1. No product in cabinet. 2. Unit in a unpredictable location. Elstat control may be going in standby mode. 8BSN1SPEVDU 3FQBJS 1. Load cabinet Elstat is equipped with a anti-short cycle that can make the unit run warm with no product. 2. Move cabinet or put into Perishable mode. 3. Unit was in a previous location. 3. Perform half reset. 1. Unit in a unpredictable location. Elstat control may be going into standby mode. 1. Move cabinet or put into Perishable mode. 2. Compressor not running. 2. Check for out put voltage at controller. If good follow compressor diagnosis. 3. Compressor running. 3. Follow refrigeration trouble shooting guides. 4. Unit in standby mode. 6OJUEJTQMBZJOHB UFNQFSBUVSFJOTUFBEPG iVTFw 1. Unit recently worked on. Parameters have been changed. 1. Reset the DIS parameter to “0”. &BTU5FSSB-BOFt0h'BMMPO .0tQItUPMMGSFFtTFSWJDF!USVFNGHDPN 9
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : ricalb Create Date : 2012:04:13 09:40:21-05:00 Modify Date : 2012:04:13 09:40:21-05:00 XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:2132ade3-73e1-4a38-939d-24bc8340c83e Document ID : adobe:docid:indd:d0fd6bcc-0cd9-11df-b957-df02beed724b Rendition Class : proof:pdf Derived From Instance ID : 36a0e184-0cd5-11df-b957-df02beed724b Derived From Document ID : adobe:docid:indd:e6ebc839-08cb-11df-b8e4-8907738ada47 Metadata Date : 2011:11:01 09:39:39-05:00 Creator Tool : Adobe InDesign CS5 (7.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11070 bytes, use -b option to extract) Format : application/pdf Title : Elstat Training Booklet.pdf Creator : ricalb Producer : Acrobat Distiller 10.1.3 (Windows) Trapped : False Page Count : 9EXIF Metadata provided by EXIF.tools