Truly Instrument DB62 BLOOD PRESSURE MONITOR User Manual 61M 1

Truly Instrument Ltd. BLOOD PRESSURE MONITOR 61M 1

2ABGT-DB62_user manual_Rev1

6. To disable Alarm, Press the ”    MEMO ” or ”PAGE    ”     button to select “OFF” and press the ”     AVG”  button  to      confirm.7. To set 1st Alarm, Press the ”    MEMO” or ”PAGE    ” button     to  select “ON”.  Press the “    AVG”  button to confirm.8. When Hour digit flashes, press the “   MEMO” or  “ PAGE    ”     button to select Hour.  Press the “    AVG”button to     confirm.9. When Minute digit flashes, press the “   MEMO” or      “PAGE    ”  button to select Minute.  Press the “    AVG”     button to confirm.10. Follow the same steps to set the 2nd, 3rd, and 4th Alarm16 17 18  Keep away the unit from direct sunlight, extreme   temperatures, humidity or moisture.Use a dry, soft cloth to clean the unit, or if desired, use a cloth lightly dampened with water.Do not use alcohol, benzene, thinner or other volatile liquids to clean the unit.Do not wash or expose the arm cuff to liquid.Remove batteries from the unit when it will not be used for more than 3 months.STORAGE  &  MAINTENANCENote: If your problem cannot be solved by the above,            consult your store of purchase. Do not disassemble            the unit.4.3  Delete Past ReadingsUser can delete all the past readings stored in each User Page.TROUBLESHOOTINGCheck if the cuff is properly connected.Replace the air tube if it is broken.Fail to inflate“Err P” displayed“Err 1” displayed“Err 2” displayed“Err 3” displayed Incorrect results Measure again.Remove interfering source e.g. mobile phones, magnets.Do not move during measurementReturn for servicing.Deflate too rapidlyMovement during measurementSignal interferenceProblem                 Cause                  SolutionNo display when you press the Power/Start buttonHave the batteries run out?Are the battery polarities wrong?Replace new batteries.Re-align batteries in correct polarities.1.  Press the “PAGE    ”  button to select the User Page      you want to delete.2.  Press and hold the “   MEMO” & “PAGE    ”  button      simultaneously for 5 seconds. Symbol of “ALL EE”      will be displayed and all past readings stored in      that User Page will be deleted.4.2  View Average Readings1.  Press the “    AVG” button to enter Average function.2.  If the User Page is not what you want to view, press the      “PAGE    ” button to select.3.  Press the “    AVG” button to view different Average      Values. 5 different Average Values are available:  Symbol on Display                    Average Values of1  h                                  One Hour1  d                                  One Day7  d                                  One Week30 d                                  One Month ALL                                  All Readings19SPECIFICATIONS11 12 13 14 15Note: -   Avoid smoking, eating or exercising for 30 minutes       before taking measurement. -   Do not move or talk during measurement. -   Measurement can be taken on either arm.1.  Place your elbow on a table and palm facing upward,      and wrap the arm cuff around the upper left arm.  2.  Pull on the end of the cuff until it wraps securely around      your upper arm.  Do not over tighten the cuff. Allow 1-2      cm or ½ inch between the bottom of the cuff and your      elbow joint.3.  Make sure the cuff is at the same level as your heart.3.1  Sitting Correctly1.  Relax2.  Sit upright in a chair with your both feet on the      floor.3.  Remove tight fitting clothing      from you upper arm and thick      clothing. Do not roll up your      sleeve if it is too tight.4.  Place your arm on a table so      that the cuff will be at the same      level as your heart.3.2  Applying the Arm Cuff3.3  User SettingThis unit allows a maximum of 4 users to store measurement records in different User Pages.3.5  Heartbeat ReadingsBesides Systolic and Diastolic values, Pulse will also be displayed after a measurementPress “PAGE    ” button to switch between User Page 1, 2, 3 and 4.3.4  Taking Measurement1.  Press the “     ” button. The cuff will automatically inflate      and the measurement will start.2.  When the measurement is complete, the cuff will      automatically deflate and your systolic and diastolic     pressure values and pulse rate will display. 3.  Remove the arm cuff and take note of your      measurement results.4.1  View Past Readings1.  Press the “   MEMO” button to enter memory function.2.  If the User Page is not what you want to view, press the      “PAGE    ” button to select.3.  Press the “   MEMO”  button to display the next sets of      values. Past readings are displayed from the most recent      to the oldest.4.  This can stored up to 99 sets of past readings for each      user (4 x 99).After measurement, the last set of measured values will be saved automatically after measurement when the unit is turned off by pressing “     ” button or by automatic poweroff after 3 minutes.Note:You can press the “     ” button to stop measurement              at any time.This unit features a 6-color LED light indicator to display blood pressure level in accordance with the WHO (World Health Organization) classification.3.6  WHO Light IndicatormmHgmmHg120  130       140    150      160     170    18011010510095908580Grade 3 hypertension(severe) (Red)Grade 2 hypertension(moderate)                                     (Yellow)Grade 1 hypertension(mild)                                (Purple)High- normal(Green)Normal(Sky Blue)Optimal(Blue)Systolic PressureDiastolic PressureWHO Light IndicatorPulseIrregular HeartbeatThis unit has a unique feature that alerts user of irregular heartbeat detection during measurement.Note:An irregular heartbeat is defined as a heartbeat rhythm that has a variation of more than25% from the average rhythm detected during measurement.If such irregular rhythm occurs twice or more during the same measurement, the display screen will show the pulse value and “IH” symbol alternately.Example:  (90 / IH)Note:Please consult your doctor if irregular heartbeat               occurs often.Regular but Below Normal HeartbeatIf the monitor detects a pulse rate below 60 beats per minute during measurement, the monitor will display the pulse value and “LO” symbol alternately.Example:  (58 / LO)Regular but Above Normal HeartbeatIf the monitor detects a pulse rate above 100 beats per minute during measurement, the monitor will display the pulse value and “HI” symbol alternately.Example:  (102 / HI)WHO Classification        ColorOptimal --------------------BlueNormal ---------------------Sky BlueHigh-normal --------------GreenMild hypertension -------PurpleModerate hypertension ---YellowSevere hypertension ----RedExample: If your measurement reading is 122/75, the LED light will display the color in blue.TAKING  MEASUREMENTMEMORY  FUNCTIONS4 5Blood Pressure MonitorDB62Instruction ManualOVERVIEWMonitorWHO LightIndictorMemory Recall(Up)Average Values(Set) Page Select(Down) Power(Start)Cuff Outlet6 7 82.1  Battery Installation1. Pull and lift on the lock to     remove the battery cover.2. Insert 4 AA batteries with     the polarities in correct     direction.3. Replace the battery cover.      Press it lightly until the lock securely clicks into place.2.2  Connect AC Adaptor (Optional)If you have the AC 6V adaptor, plug it into the AC adaptor jack at the top of the device.  Remove batteries when using the AC adaptor.2.3  Date & Time SettingNote: -   Set the correct date and time before taking a       measurement. -   Date and time should be reset after replacing new       batteries.Note: Replace batteries when the battery indicator  “      ”            shows low voltage.1. Press and hold the ”     AVG”  button for a few seconds     until the Year display flashes.2. Press the“    MEMO” or ”PAGE    ”  button to select the     current year.3. Press the “    AVG”  button to confirm Year Setting.4. Follow the same steps to set the Month, Date, Hour and     Minute.5. You can choose Clock Function “ON” or “OFF” while the     monitor is not in use. Press “   MEMO” or ” PAGE    ” button     to select. Press the ”     AVG ”  button to confirm.Noted: If you select Clock Function “ON”, you will continue               at the Alarm Setting section. Otherwise, setting will               end.910DisplayKilopascalUser 1-4MemoryDate & YearSystolicDiastolicPulseLow BatteryIndicatorMemory No.(1-99 readings)Pulse SymbolPackage ContentsMain UnitArm Cuff          4 x AAAlkaline BatteriesMemory Average2.5  Language SettingWhen a measurement is completed, DB62V will read aloud the systolic value, diastolic value and pulse automatically. The default language is English.1.  Press and hold the “   MEMO” button until the screen      displays [LLLx] (x = 0 ~ 7), then release the button. 2.  Press the “   MEMO” button to select language.      Number 0 ~ 7 represents the following languages:     0   Mute     1   English     2   German     3   Russian     4   Polish     5   Czech     6    Turkish     7    Chinese3.  Press the “    ” button to confirm the selection and begin      measurement.PREPARATION2.4  Alarm SettingNote: -   You will not be able to set alarm clock if Clock Function       is set to “OFF”. -   You can set a maximum of 4 alarms.Note: -   Press the “     ” button anytime during clock setting/     alarm setting to start over if an error occurs.  -   Each alarm clock lasts 45 seconds, or you can turn it off      by pressing the “     ” button.SIZE:84*145MM  正面SIZE:84*145MM  反面Manufactured in accordance with International StandardsManufacturer:    Truly Instrument Ltd.                                         2/F, Chung Shun Knitting Centre,                                         1-3 Wing Yip St., Kwai Chung, N.T.,                                         Hong KongTEL:           (852) 24879803FAX:           (852) 21465756Model No.Measurement MethodMeasurement RangeAccuracyInflationPressure DetectionPower SupplyAuto Power OffStorage EnvironmentOperation EnvironmentExternal DimensionsNet WeightCuff DimensionsPackage ContentDB62OscillometricPressure: 20 – 280 mmHgPulse Rate: 40 – 195 beats/minPressure: +/- 3 mmHgPulse Rate: +/- 5%Pump drivenSemi-conductor4 x AA batteries or AC/DC adaptor3 minutes after last operation-20°C to 60°C, 10% to 95% RH10°C to 40°C, 30% to 85% RH4.7” (L) x 5.5” (W) x 2.8” (H) or12 (L) x 14 (W) x 7 (H) cm370g (batteries excluded)For arm circumference of 22-34 cm (Special size to be ordered separately)Cuff, Instruction Manual, Battery Set, Warranty CardNote: Subject to modification without prior notice.0123EC-Representative:Wellkang Ltd t/a Wellkang Tech Consulting                                         Suite B, 29 Harley Street, LONDON W1G 9QR,                                          United KingdomRev.02013/11/1132Babies, young children or individuals who cannot express their consent are not suitable to take blood pressure measurement.Individuals with serious arteriosclerosis are not suitable to take blood pressure measurement.Blood pressure readings may change in case of pregnancy. Pregnant women can consult their doctor before taking measurement.Self-measurement is not medical treatment. If there are unusual values, please consult your doctor.Handling batteries properly:   -  As soon as old batteries run out, replace with new        batteries.   -  Do not use old and new batteries together.   -  Align the polarities of batteries correctly.   -  When the unit will not be used for more than 3        months, remove the batteries. Otherwise, batteries        may leak and cause damage to the unit.Handling AC adapter properly:   -  Never unplug the power cord with wet hands.   -  Use only the original AC adapter designed for this unit.SAFETY  PRECAUTIONS QUICK  START  GUIDEAvoid smoking, eating or exercising for 30 minutes before taking measurement 2.  Remove tight fitting clothing      from you upper arm and thick      clothing.1.  Sit upright in a chair with your      both feet on the floor. 3.  Pull on the end of the cuff until      it wraps securely around your      upper arm. Place your arm on a table so that the      cuff will be at the same level as your heart.7.  When the measurement is complete,      the cuff will  automatically deflate and      your systolic and diastolic pressure      values and pulse rate will      display on Blood Pressure      monitor & save on iOS      application screen.8.  After that check the      measurement history on      History screen or chart screen by iOS application. 4.  Connect iOS device via Bluetooth (Turn Bluetooth "On"      under the "Settings" menu on the iOS device).5.  Open "TRULY" application, and then press the Blood      Pressure icon            on Measure screen.6.  Press the “     ” button. The cuff will automatically inflate      and the measurement will start.Setup ProceduresInstallationPrior to first use, Download and install "TRULY" application to your iOS device.(Bluetooth 4.0 capabilities, e.g. iPhone 4S, iPhone 5, NewiPad and iPadMini).Features      Bluetooth 4.0 compatible      One Touch Operation      Irregular Heartbeat Detector        Blood Pressure Mode and Clock Mode      4 User / 396 Total Memory      4 Alarm Clock Settings      5 Mode Averaging Function – Hour, Day,       Week, Month, and Overall      WHO Blood Pressure Indicator      Auto-off Power Saving Feature      Operated by 4 AA batteries(AC Adapter optional) All other devices shall bear the following statement in a conspicuous location on the device:This device complles with part 15 of the FCC Rules. Operation is subject to the fol-lowing two conditions:(1) This device may not cause harmful interference, and (2) this device must accept any interference re-ceived, including interference that may cause undesired operation.
FCCStatementThisequipmenthasbeentestedandfoundtocomplywiththelimitsforaClassBdigitaldevice,pursuanttopart15ofFCCRules.Theselimitsaredesignedtoprovidereasonableprotectionagainstharmfulinterferenceinaresidentialinstallation.Thisequipmentgeneratesandcanradiateradiofrequencyenergyand,ifnotinstalledandusedinaccordancewiththeinstructions,maycauseharmfulinterferencetoradiocommunications.However,thereisnoguaranteethatinterferencewillnotoccurinaparticularinstallation.Ifthisequipmentdoescauseharmfulinterferencetoradioortelevisionreception,whichcanbedeterminedbyturningtheequipmentoffandon,theuserisencouragedtotrytocorrectTheinterferencebyoneormoreofthefollowingmeasures:Reorientorrelocatethereceivingantenna.Increasetheseparationbetweentheequipmentandreceiver.Connecttheequipmentintoanoutletonacircuitdifferentfromthattowhichthereceiverisconnected.Consultthedealeroranexperiencedradio/TVtechnicianforhelp.ThisdevicecomplieswithPart15ofFCCRules.Operationissubjecttothefollowingtwoconditions:Thisdevicemaynotcauseharmfulinterference,andThisdevicemustacceptanyinterferencereceived,includinginterferencethatmaycauseundesiredoperation.Note:ThemanufacturerisnotresponsibleforanyradioorTVinterferencecausedbyunauthorizedmodificationstothisequipment.suchmodificationscouldvoidtheuser’sauthoritytooperatethisequipment.

Navigation menu